1
|
Mraz AL, Weir MH. Knowledge to Predict Pathogens: Legionella pneumophila Lifecycle Systematic Review Part II Growth within and Egress from a Host Cell. Microorganisms 2022; 10:141. [PMID: 35056590 PMCID: PMC8780890 DOI: 10.3390/microorganisms10010141] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 12/30/2021] [Accepted: 01/04/2022] [Indexed: 11/17/2022] Open
Abstract
Legionella pneumophila (L. pneumophila) is a pathogenic bacterium of increasing concern, due to its ability to cause a severe pneumonia, Legionnaires' Disease (LD), and the challenges in controlling the bacteria within premise plumbing systems. L. pneumophila can thrive within the biofilm of premise plumbing systems, utilizing protozoan hosts for protection from environmental stressors and to increase its growth rate, which increases the bacteria's infectivity to human host cells. Typical disinfectant techniques have proven to be inadequate in controlling L. pneumophila in the premise plumbing system, exposing users to LD risks. As the bacteria have limited infectivity to human macrophages without replicating within a host protozoan cell, the replication within, and egress from, a protozoan host cell is an integral part of the bacteria's lifecycle. While there is a great deal of information regarding how L. pneumophila interacts with protozoa, the ability to use this data in a model to attempt to predict a concentration of L. pneumophila in a water system is not known. This systematic review summarizes the information in the literature regarding L. pneumophila's growth within and egress from the host cell, summarizes the genes which affect these processes, and calculates how oxidative stress can downregulate those genes.
Collapse
Affiliation(s)
- Alexis L. Mraz
- School of Nursing, Health, Exercise Science, The College of New Jersey, P.O. Box 7718, 2000 Pennington Rd., Ewing, NJ 08628, USA
| | - Mark H. Weir
- Division of Environmental Health Sciences, College of Public Health, The Ohio State University, Columbus, OH 43210, USA;
- Sustainability Institute, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
2
|
Kurajica L, Ujević Bošnjak M, Kinsela AS, Štiglić J, Waite TD, Capak K, Pavlić Z. Effects of changing supply water quality on drinking water distribution networks: Changes in NOM optical properties, disinfection byproduct formation, and Mn deposition and release. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 762:144159. [PMID: 33360458 DOI: 10.1016/j.scitotenv.2020.144159] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 11/26/2020] [Accepted: 11/26/2020] [Indexed: 06/12/2023]
Abstract
Field studies were conducted in a Croatian city supplied by two distinct groundwater sources (referred to as A and B) to investigate both the effects of changing water source on the water quality in the drinking water supply system, as well as to further understand discoloration events that occurred in city locations that switched water from source A to B. The water treatment processes at site A were found to alter organic matter (OM) characteristics, removing humic substances while enhancing protein-derived (tryptophan) content. Although the humic-like component predominated in raw waters, microbially/protein-derived components were found to increase throughout the distribution networks of both systems. Disinfection byproducts (DBPs) such as total trihalomethane (TTHM) and total haloacetic acid (THAA) were prevalent in water distribution system (WDS)-A, which correlated with elevated OM content as well as re-chlorination with hypochlorite (NaOCl). Our field study revealed that THMs were more readily formed than HAAs during ClO2 treatment. Unsurprisingly, chlorite concentrations were generally higher than chlorate concentrations during ClO2 treatment, whereas (secondary) NaOCl disinfection contributed to higher chlorate production. Principal component analysis indicated that variable pH values and humic-like OM could affect Mn, As and Al concentrations at the consumer's tap. Our results suggested that although Mn concentrations complied with regulations at WDS-B and were below 50 μg/L after disinfection, Mn was oxidized and formed particulate Mn oxides capable of causing discoloration events depending on prevailing network physico-chemical and hydraulic conditions. Aluminium also appears to be released during hydraulic disturbances from extensive deposits within the network. Thermodynamic calculations showed that Mn-oxidation was strongly dependent upon the ORP, and to lesser extent the pH value. Collectively, our results confirm that ensuring the provision of safe drinking waters to consumers requires an understanding of water quality across entire distribution networks in addition to any routine post-treatment monitoring.
Collapse
Affiliation(s)
- L Kurajica
- Croatian Institute of Public Health, Rockefeller street 7, 10000 Zagreb, Croatia
| | - M Ujević Bošnjak
- Croatian Institute of Public Health, Rockefeller street 7, 10000 Zagreb, Croatia.
| | - A S Kinsela
- Water Research Centre, University of New South Wales, Sydney, NSW 2052, Australia
| | - J Štiglić
- Croatian Institute of Public Health, Rockefeller street 7, 10000 Zagreb, Croatia
| | - T D Waite
- Water Research Centre, University of New South Wales, Sydney, NSW 2052, Australia
| | - K Capak
- Croatian Institute of Public Health, Rockefeller street 7, 10000 Zagreb, Croatia
| | - Z Pavlić
- Slavonski Brod Water Supply Company, Nikole Zrinskog 25, 35000 Slavonski Brod, Croatia
| |
Collapse
|
3
|
Li RA, McDonald JA, Sathasivan A, Khan SJ. Disinfectant residual stability leading to disinfectant decay and by-product formation in drinking water distribution systems: A systematic review. WATER RESEARCH 2019; 153:335-348. [PMID: 30743084 DOI: 10.1016/j.watres.2019.01.020] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 01/02/2019] [Accepted: 01/04/2019] [Indexed: 06/09/2023]
Abstract
Secondary disinfectants, such as chlorine and chloramine, have been widely applied to minimise microbial risks in drinking water during distribution. Key challenges have included the maintenance of stable concentrations of disinfectant residuals and the control of disinfection by-products that may form as a consequence of residual decay processes. Many factors may influence disinfectant residual stability and the consequential formation of by-products. Thus predictions of disinfectant stability and by-product formation are multifactorial problems, complete with numerous complications of parameter co-dependence and feedback amplification of some key parameters. The aim of this review was to derive an understanding of how disinfectant residual stability in drinking water distribution systems is impacted by various influencing factors such as water quality and operational parameters. Factors known to influence disinfectant stability and by-product formation were critically reviewed. A systematic review method was applied to identify 1809 journal articles published in the two decades from January 1998 to December 2017. From the initial screening, 161 papers were selected for detailed assessment. Important factors were identified to include temperature, water age, piping material, corrosion products, pH, hydraulic condition, disinfectant residual type and dosage and microbial activity. Microbial activity is a particularly complex parameter on which to base predictions since many factors are known to influence the degree and nature of such activity. These include temperature, water age, piping material, corrosion products, nutrients, natural organic matter, hydraulic condition and disinfectant residual type and dosage. Disinfectant types and dosages were found to be among the most important factors. Many knowledge gaps and research needs still remain, including the need for a more complete understanding of the factors that influence the production of nitrogenous disinfection by-products.
Collapse
Affiliation(s)
- Rebecca A Li
- UNSW Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, NSW, 2052, Australia.
| | - James A McDonald
- UNSW Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, NSW, 2052, Australia.
| | - Arumugam Sathasivan
- School of Computing Engineering and Mathematics, University of Western Sydney, Kingswood, NSW, 2747, Australia.
| | - Stuart J Khan
- UNSW Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, NSW, 2052, Australia.
| |
Collapse
|
4
|
Younas H, Fei Y, Shao J, He Y. Developing an antibacterial super-hydrophilic barrier between bacteria and membranes to mitigate the severe impacts of biofouling. BIOFOULING 2016; 32:1089-1102. [PMID: 27669899 DOI: 10.1080/08927014.2016.1229775] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Accepted: 08/22/2016] [Indexed: 06/06/2023]
Abstract
Biofouling produces concentrated microbial populations with highly resistive biofilms and is considered to be a serious obstacle for a wide range of membrane technology applications. An antibacterial super-hydrophilic barrier could help to reduce biofouling by preventing direct contact between membranes and bacteria. In this study, an antibacterial super-hydrophilic barrier consisting of a layer of TiO2 nanoparticles (NPs) was developed on polyvinylidene fluoride (PVDF)-based membrane via a facile technique. The results demonstrated that the presence of TiO2 NPs eliminated the first step of biofouling, ie bacterial adhesion to the membrane. In addition, after bacterial deposition onto the membrane during ultrafiltration (UF), the TiO2 NPs significantly retarded bacterial growth and reproduction (the second step of biofouling). During UF, the membrane flux decreased due to bacterial deposition, but 85% of the flux was recovered through physical cleaning using water. This study sheds light on the potential advantages of antibacterial super-hydrophilic membranes for biofouling mitigation.
Collapse
Affiliation(s)
- Hassan Younas
- a School of Environmental Science and Engineering , Shanghai Jiao Tong University , Shanghai , PR China
| | - Yuhuan Fei
- a School of Environmental Science and Engineering , Shanghai Jiao Tong University , Shanghai , PR China
| | - Jiahui Shao
- a School of Environmental Science and Engineering , Shanghai Jiao Tong University , Shanghai , PR China
| | - Yiliang He
- a School of Environmental Science and Engineering , Shanghai Jiao Tong University , Shanghai , PR China
| |
Collapse
|
5
|
Liu S, Gunawan C, Barraud N, Rice SA, Harry EJ, Amal R. Understanding, Monitoring, and Controlling Biofilm Growth in Drinking Water Distribution Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2016; 50:8954-8976. [PMID: 27479445 DOI: 10.1021/acs.est.6b00835] [Citation(s) in RCA: 191] [Impact Index Per Article: 23.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In drinking water distribution systems (DWDS), biofilms are the predominant mode of microbial growth, with the presence of extracellular polymeric substance (EPS) protecting the biomass from environmental and shear stresses. Biofilm formation poses a significant problem to the drinking water industry as a potential source of bacterial contamination, including pathogens, and, in many cases, also affecting the taste and odor of drinking water and promoting the corrosion of pipes. This article critically reviews important research findings on biofilm growth in DWDS, examining the factors affecting their formation and characteristics as well as the various technologies to characterize and monitor and, ultimately, to control their growth. Research indicates that temperature fluctuations potentially affect not only the initial bacteria-to-surface attachment but also the growth rates of biofilms. For the latter, the effect is unique for each type of biofilm-forming bacteria; ammonia-oxidizing bacteria, for example, grow more-developed biofilms at a typical summer temperature of 22 °C compared to 12 °C in fall, and the opposite occurs for the pathogenic Vibrio cholerae. Recent investigations have found the formation of thinner yet denser biofilms under high and turbulent flow regimes of drinking water, in comparison to the more porous and loosely attached biofilms at low flow rates. Furthermore, in addition to the rather well-known tendency of significant biofilm growth on corrosion-prone metal pipes, research efforts also found leaching of growth-promoting organic compounds from the increasingly popular use of polymer-based pipes. Knowledge of the unique microbial members of drinking water biofilms and, importantly, the influence of water characteristics and operational conditions on their growth can be applied to optimize various operational parameters to minimize biofilm accumulation. More-detailed characterizations of the biofilm population size and structure are now feasible with fluorescence microscopy (epifluorescence and CLSM imaging with DNA, RNA, EPS, and protein and lipid stains) and electron microscopy imaging (ESEM). Importantly, thorough identification of microbial fingerprints in drinking water biofilms is achievable with DNA sequencing techniques (the 16S rRNA gene-based identification), which have revealed a prevalence of previously undetected bacterial members. Technologies are now moving toward in situ monitoring of biomass growth in distribution networks, including the development of optical fibers capable of differentiating biomass from chemical deposits. Taken together, management of biofilm growth in water distribution systems requires an integrated approach, starting from the treatment of water prior to entering the networks to the potential implementation of "biofilm-limiting" operational conditions and, finally, ending with the careful selection of available technologies for biofilm monitoring and control. For the latter, conventional practices, including chlorine-chloramine disinfection, flushing of DWDS, nutrient removal, and emerging technologies are discussed with their associated challenges.
Collapse
Affiliation(s)
| | - Cindy Gunawan
- ithree institute, University of Technology Sydney , Sydney, NSW 2007, Australia
| | - Nicolas Barraud
- Department of Microbiology, Genetics of Biofilms Unit, Institut Pasteur , Paris 75015, France
| | - Scott A Rice
- The Singapore Centre for Environmental Life Sciences Engineering and School of Biological Sciences, Nanyang Technological University , 639798, Singapore
| | - Elizabeth J Harry
- ithree institute, University of Technology Sydney , Sydney, NSW 2007, Australia
| | | |
Collapse
|
6
|
Brazeau RH, Edwards MA. Role of Hot Water System Design on Factors Influential to Pathogen Regrowth: Temperature, Chlorine Residual, Hydrogen Evolution, and Sediment. ENVIRONMENTAL ENGINEERING SCIENCE 2013; 30:617-627. [PMID: 24170969 PMCID: PMC3804227 DOI: 10.1089/ees.2012.0514] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Accepted: 07/13/2013] [Indexed: 05/25/2023]
Abstract
Residential water heating is linked to growth of pathogens in premise plumbing, which is the primary source of waterborne disease in the United States. Temperature and disinfectant residual are critical factors controlling increased concentration of pathogens, but understanding of how each factor varies in different water heater configurations is lacking. A direct comparative study of electric water heater systems was conducted to evaluate temporal variations in temperature and water quality parameters including dissolved oxygen levels, hydrogen evolution, total and soluble metal concentrations, and disinfectant decay. Recirculation tanks had much greater volumes of water at temperature ranges with potential for increased pathogen growth when set at 49°C compared with standard tank systems without recirculation. In contrast, when set at the higher end of acceptable ranges (i.e., 60°C), this relationship was reversed and recirculation systems had less volume of water at risk for pathogen growth compared with conventional systems. Recirculation tanks also tended to have much lower levels of disinfectant residual (standard systems had 40-600% higher residual), 4-6 times as much hydrogen, and 3-20 times more sediment compared with standard tanks without recirculation. On demand tankless systems had very small volumes of water at risk and relatively high levels of disinfectant residual. Recirculation systems may have distinct advantages in controlling pathogens via thermal disinfection if set at 60°C, but these systems have lower levels of disinfectant residual and greater volumes at risk if set at lower temperatures.
Collapse
Affiliation(s)
- Randi H. Brazeau
- Department of Earth and Atmospheric Sciences, Metropolitan State University of Denver, Denver, Colorado
| | - Marc A. Edwards
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia
| |
Collapse
|
7
|
Ginige MP, Wylie J, Plumb J. Influence of biofilms on iron and manganese deposition in drinking water distribution systems. BIOFOULING 2011; 27:151-163. [PMID: 21229405 DOI: 10.1080/08927014.2010.547576] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Although health risk due to discoloured water is minimal, such water continues to be the source of one of the major complaints received by most water utilities in Australia. Elevated levels of iron (Fe) and/or manganese (Mn) in bulk water are associated with discoloured water incidents. The accumulation of these two elements in distribution systems is believed to be one of the main causes for such elevated levels. An investigation into the contribution of pipe wall biofilms towards Fe and Mn deposition, and discoloured water events is reported in this study. Eight laboratory-scale reactors were operated to test four different conditions in duplicate. Four reactors were exposed to low Fe (0.05 mg l(-1)) and Mn (0.02 mg l(-1)) concentrations and the remaining four were exposed to a higher (0.3 and 0.4 mg l(-1) for Fe and Mn, respectively) concentration. Two of the four reactors which received low and high Fe and Mn concentrations were chlorinated (3.0 mg l(-1) of chlorine). The biological activity (measured in terms of ATP) on the glass rings in these reactors was very low (∼1.5 ng cm(-2) ring). Higher concentrations of Fe and Mn in bulk water and active biofilms resulted in increased deposition of Fe and Mn on the glass rings. Moreover, with an increase in biological activity, an increase in Fe and Mn deposition was observed. The observations in the laboratory-scale experiments were in line with the results of field observations that were carried out using biofilm monitors. The field data additionally demonstrated the effect of seasons, where increased biofilm activities observed on pipe wall biofilms during late summer and early autumn were found to be associated with increased deposition of Fe and Mn. In contrast, during the cooler months, biofilm activities were a magnitude lower and the deposited metal concentrations were also significantly less (ie a drop of 68% for Fe and 86% for Mn). Based on the laboratory-scale investigations, detachment of pipe wall biofilms due to cell death or flow dynamics could release the entrapped Fe and Mn into the bulk water, which could lead to a discoloured water event. Hence, managing biofilm growth on drinking water pipelines should be considered by water utilities to minimize accumulation of Fe and Mn in distribution networks.
Collapse
|
8
|
Decho AW, Frey RL, Ferry JL. Chemical challenges to bacterial AHL signaling in the environment. Chem Rev 2010; 111:86-99. [PMID: 21142012 DOI: 10.1021/cr100311q] [Citation(s) in RCA: 96] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Alan W Decho
- Department of Environmental Health Sciences, Arnold School of Public Health, University of South Carolina, Columbia, South Carolina 29208, USA.
| | | | | |
Collapse
|
9
|
Upadhyayula VKK, Deng S, Mitchell MC, Smith GB. Application of carbon nanotube technology for removal of contaminants in drinking water: a review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2009; 408:1-13. [PMID: 19819525 DOI: 10.1016/j.scitotenv.2009.09.027] [Citation(s) in RCA: 179] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2009] [Revised: 09/11/2009] [Accepted: 09/15/2009] [Indexed: 05/10/2023]
Abstract
Carbon nanotube (CNT) adsorption technology has the potential to support point of use (POU) based treatment approach for removal of bacterial pathogens, natural organic matter (NOM), and cyanobacterial toxins from water systems. Unlike many microporous adsorbents, CNTs possess fibrous shape with high aspect ratio, large accessible external surface area, and well developed mesopores, all contribute to the superior removal capacities of these macromolecular biomolecules and microorganisms. This article provides a comprehensive review on application of CNTs as adsorbent media to concentrate and remove pathogens, NOM, and cyanobacterial (microcystin derivatives) toxins from water systems. The paper also surveys on consideration of CNT based adsorption filters for removal of these contaminants from cost, operational and safety standpoint. Based on the studied literature it appears that POU based CNT technology looks promising, that can possibly avoid difficulties of treating biological contaminants in conventional water treatment plants, and thereby remove the burden of maintaining the biostability of treated water in the distribution systems.
Collapse
Affiliation(s)
- Venkata K K Upadhyayula
- Microbiology and Applied Biochemistry Division, Air Force Research Labs, 139 Barnes Drive, Suite II, Tyndall Air Force Base, Panama City, FL 32403, United States.
| | | | | | | |
Collapse
|
10
|
Park SJ, Lee CG, Kim SB. The role of phosphate in bacterial interaction with iron-coated surfaces. Colloids Surf B Biointerfaces 2009; 68:79-82. [DOI: 10.1016/j.colsurfb.2008.09.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2008] [Revised: 08/18/2008] [Accepted: 09/16/2008] [Indexed: 11/26/2022]
|
11
|
Shirtliff ME, Bargmeyer A, Camper AK. Assessment of the ability of the bioelectric effect to eliminate mixed-species biofilms. Appl Environ Microbiol 2005; 71:6379-82. [PMID: 16204561 PMCID: PMC1265951 DOI: 10.1128/aem.71.10.6379-6382.2005] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Microbes have been able to persist in water distribution systems through the development of multicellular communities known as biofilms. This study evaluated the usefulness of the bioelectric effect for the elimination of water distribution system biofilms from annular reactors. The bioelectric effect did not have any bactericidal action either alone or when coupled with free chlorine.
Collapse
Affiliation(s)
- Mark E Shirtliff
- Department of Biomedical Sciences, Dental School, University of Maryland-Baltimore, 666 W. Baltimore Street, Baltimore, MD 21201, USA.
| | | | | |
Collapse
|
12
|
Morton SC, Zhang Y, Edwards MA. Implications of nutrient release from iron metal for microbial regrowth in water distribution systems. WATER RESEARCH 2005; 39:2883-92. [PMID: 16029882 DOI: 10.1016/j.watres.2005.05.024] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2004] [Revised: 05/03/2005] [Accepted: 05/04/2005] [Indexed: 05/03/2023]
Abstract
Control of microbial regrowth in iron pipes is a major challenge for water utilities. This work examines the inter-relationship between iron corrosion and bacterial regrowth, with a special focus on the potential of iron pipe to serve as a source of phosphorus. Under some circumstances, corroding iron and steel may serve as a source for all macronutrients necessary for bacterial regrowth including fixed carbon, fixed nitrogen and phosphorus. Conceptual models and experimental data illustrate that levels of phosphorus released from corroding iron are significant relative to that necessary to sustain high levels of biofilm bacteria. Consequently, it may not be possible to control regrowth on iron surfaces by limiting phosphorus in the bulk water.
Collapse
Affiliation(s)
- Siyuan C Morton
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, 407 Durham Hall, Blacksburg, VA 24061-0246, USA
| | | | | |
Collapse
|
13
|
Parsek MR, Fuqua C. Biofilms 2003: emerging themes and challenges in studies of surface-associated microbial life. J Bacteriol 2004; 186:4427-40. [PMID: 15231774 PMCID: PMC438604 DOI: 10.1128/jb.186.14.4427-4440.2004] [Citation(s) in RCA: 104] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Matthew R Parsek
- The University of Iowa, Department of Microbiology, 540E EMRB, Iowa City, IA 52242-1109, USA.
| | | |
Collapse
|
14
|
Abstract
There appear to be interactions in the distribution system that complicate the ability to use AOC/BDOC as an independent assessment of regrowth potential. Two such complications are the limitation of the assays themselves and the potential interaction between the organic carbon concentration with the presence of disinfectants and pipe materials. To address these interactions, a series of experiments spanning several years have been conducted in model distribution systems at the Center for Biofilm Engineering (CBE) using soil-derived humics. When compared to easily utilized organics, humic substances supported the same order of magnitude of biofilm organisms. As carbon concentration was increased from 500 to 1000 to 2000 ppb, there was no increase in growth rate of the organisms, suggesting zero-order kinetics. If the system was chlorinated, there was less biomass, but growth rates were higher. In the presence of corrosion products, humic-fed systems supported more organisms than a control system fed biologically treated water. When free chlorine was maintained at a residual of about 0.2 mg/l, biofilm numbers on the surfaces were reduced. Phosphate alone did not result in fewer bacteria, while a combination of chorine and phosphate had the best results (lowest biofilm numbers). Adjustment to pH 9 was not effective. Recently completed work compared increasing levels of humic substances in the presence of free chlorine and monochloramine on biofilm growth on a number of surfaces (PVC, epoxy, cement, ductile iron). As the concentration of humic substances was increased from 0, 0.5 to 2 mg/l, there was an increase in biofilm numbers on all surfaces. This effect was the most pronounced on iron surfaces. These results illustrate that carbon compounds not measured by the BDOC or AOC tests may profoundly influence biofilm numbers. In addition, iron surfaces are at much higher risk for elevated biofilm counts in the presence of humic substances, even if disinfection is practiced. However, corrosion control may mitigate this interaction.
Collapse
Affiliation(s)
- Anne K Camper
- Center for Biofilm Engineering, Montana State University, 366 EPS Building, Bozeman, MT 59718, USA.
| |
Collapse
|