1
|
Chan LM, Courteau BJ, Maker A, Wu M, Basanta B, Mehmood H, Bulkley D, Joyce D, Lee BC, Mick S, Czarnik C, Gulati S, Lander GC, Verba KA. High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector. J Struct Biol 2024:108108. [PMID: 38944401 DOI: 10.1016/j.jsb.2024.108108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 06/03/2024] [Accepted: 06/26/2024] [Indexed: 07/01/2024]
Abstract
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ∼ 4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope fitted with a non-standard SP-Twin lens. We also achieved a ∼ 3.2 Å resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine's capability for high-resolution data acquisition and screening on lower-end systems by obtaining ∼ 3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.
Collapse
Affiliation(s)
- Lieza M Chan
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - Brandon J Courteau
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - Allison Maker
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - Mengyu Wu
- Department of Integrative Structural and Computational Biology, Scripps Research, La Jolla, CA 92024, United States
| | - Benjamin Basanta
- Department of Integrative Structural and Computational Biology, Scripps Research, La Jolla, CA 92024, United States
| | - Hevatib Mehmood
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - David Bulkley
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | | | | | | | | | | | - Gabriel C Lander
- Department of Integrative Structural and Computational Biology, Scripps Research, La Jolla, CA 92024, United States
| | - Kliment A Verba
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States.
| |
Collapse
|
2
|
Chan LM, Courteau BJ, Maker A, Wu M, Basanta B, Mehmood H, Bulkley D, Joyce D, Lee BC, Mick S, Gulati S, Lander GC, Verba KA. High-resolution single-particle imaging at 100-200 keV with the Gatan Alpine direct electron detector. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.02.14.580363. [PMID: 38405886 PMCID: PMC10888765 DOI: 10.1101/2024.02.14.580363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
Developments in direct electron detector technology have played a pivotal role in enabling high-resolution structural studies by cryo-EM at 200 and 300 keV. Yet, theory and recent experiments indicate advantages to imaging at 100 keV, energies for which the current detectors have not been optimized. In this study, we evaluated the Gatan Alpine detector, designed for operation at 100 and 200 keV. Compared to the Gatan K3, Alpine demonstrated a significant DQE improvement at these voltages, specifically a ~4-fold improvement at Nyquist at 100 keV. In single-particle cryo-EM experiments, Alpine datasets yielded better than 2 Å resolution reconstructions of apoferritin at 120 and 200 keV on a ThermoFisher Scientific (TFS) Glacios microscope. We also achieved a ~3.2 Å resolution reconstruction for a 115 kDa asymmetric protein complex, proving its effectiveness with complex biological samples. In-depth analysis revealed that Alpine reconstructions are comparable to K3 reconstructions at 200 keV, and remarkably, reconstruction from Alpine at 120 keV on a TFS Glacios surpassed all but the 300 keV data from a TFS Titan Krios with GIF/K3. Additionally, we show Alpine's capability for high-resolution data acquisition and screening on lower-end systems by obtaining ~3 Å resolution reconstructions of apoferritin and aldolase at 100 keV and detailed 2D averages of a 55 kDa sample using a side-entry cryo holder. Overall, we show that Gatan Alpine performs well with the standard 200 keV imaging systems and may potentially capture the benefits of lower accelerating voltages, possibly bringing smaller sized particles within the scope of cryo-EM.
Collapse
Affiliation(s)
- Lieza M Chan
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - Brandon J Courteau
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - Allison Maker
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - Mengyu Wu
- Department of Integrative Structural and Computational Biology, Scripps Research, La Jolla, CA 92024, United States
| | - Benjamin Basanta
- Department of Integrative Structural and Computational Biology, Scripps Research, La Jolla, CA 92024, United States
| | - Hevatib Mehmood
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| | - David Bulkley
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | | | | | | | | | - Gabriel C Lander
- Department of Integrative Structural and Computational Biology, Scripps Research, La Jolla, CA 92024, United States
| | - Kliment A Verba
- Department of Cellular and Molecular Pharmacology, University of California, San Francisco, CA 94158, United States
| |
Collapse
|
3
|
Takizawa Y, Kurumizaka H. Chromatin structure meets cryo-EM: Dynamic building blocks of the functional architecture. BIOCHIMICA ET BIOPHYSICA ACTA. GENE REGULATORY MECHANISMS 2022; 1865:194851. [PMID: 35952957 DOI: 10.1016/j.bbagrm.2022.194851] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 08/04/2022] [Accepted: 08/04/2022] [Indexed: 06/15/2023]
Abstract
Chromatin is a dynamic molecular complex composed of DNA and proteins that package the DNA in the nucleus of eukaryotic cells. The basic structural unit of chromatin is the nucleosome core particle, composed of ~150 base pairs of genomic DNA wrapped around a histone octamer containing two copies each of four histones, H2A, H2B, H3, and H4. Individual nucleosome core particles are connected by short linker DNAs, forming a nucleosome array known as a beads-on-a-string fiber. Higher-order structures of chromatin are closely linked to nuclear events such as replication, transcription, recombination, and repair. Recently, a variety of chromatin structures have been determined by single-particle cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET), and their structural details have provided clues about the chromatin architecture functions in the cell. In this review, we highlight recent cryo-EM structural studies of a fundamental chromatin unit to clarify the functions of chromatin.
Collapse
Affiliation(s)
- Yoshimasa Takizawa
- Laboratory of Chromatin Structure and Function, Institute for Quantitative Biosciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-0032, Japan
| | - Hitoshi Kurumizaka
- Laboratory of Chromatin Structure and Function, Institute for Quantitative Biosciences, The University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-0032, Japan.
| |
Collapse
|
4
|
Sun M, Azumaya CM, Tse E, Bulkley DP, Harrington MB, Gilbert G, Frost A, Southworth D, Verba KA, Cheng Y, Agard DA. Practical considerations for using K3 cameras in CDS mode for high-resolution and high-throughput single particle cryo-EM. J Struct Biol 2021; 213:107745. [PMID: 33984504 DOI: 10.1016/j.jsb.2021.107745] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 04/16/2021] [Accepted: 05/06/2021] [Indexed: 10/21/2022]
Abstract
Detector technology plays a pivotal role in high-resolution and high-throughput cryo-EM structure determination. Compared with the first-generation, single-electron counting direct detection camera (Gatan K2), the latest K3 camera is faster, larger, and now offers a correlated-double sampling mode (CDS). Importantly this results in a higher DQE and improved throughput compared to its predecessor. In this study, we focused on optimizing camera data collection parameters for daily use within a cryo-EM facility and explored the balance between throughput and resolution. In total, eight data sets of murine heavy-chain apoferritin were collected at different dose rates and magnifications, using 9-hole image shift data collection strategies. The performance of the camera was characterized by the quality of the resultant 3D reconstructions. Our results demonstrated that the Gatan K3 operating in CDS mode outperformed standard (nonCDS) mode in terms of reconstruction resolution in all tested conditions with 8 electrons per pixel per second being the optimal dose rate. At low magnification (64kx) we were able to achieve reconstruction resolutions of 149% of the physical Nyquist limit (1.8 Å with a 1.346 Å physical pixel size). Low magnification allows more particles to be collected per image, aiding analysis of heterogeneous samples requiring large data sets. At moderate magnification (105kx, 0.834 Å physical pixel size) we achieved a resolution of 1.65 Å within 8-h of data collection, a condition optimal for achieving high-resolution on well behaved samples. Our results also show that for an optimal sample like apoferritin, one can achieve better than 2.5 Å resolution with 5 min of data collection. Together, our studies validate the most efficient ways of imaging protein complexes using the K3 direct detector and will greatly benefit the cryo-EM community.
Collapse
Affiliation(s)
- Ming Sun
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | - Caleigh M Azumaya
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | - Eric Tse
- Institute for Neurodegenerative Diseases, University of California, San Francisco, CA 94158, United States
| | - David P Bulkley
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | - Matthew B Harrington
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | - Glenn Gilbert
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States
| | - Adam Frost
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States; Quantitative Biosciences Institute (QBI), University of California, San Francisco, CA 94158, United States
| | - Daniel Southworth
- Institute for Neurodegenerative Diseases, University of California, San Francisco, CA 94158, United States
| | - Kliment A Verba
- Quantitative Biosciences Institute (QBI), University of California, San Francisco, CA 94158, United States; Department of Pharmaceutical Chemistry, University of California, San Francisco, CA 94158, United States
| | - Yifan Cheng
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States; Howard Hughes Medical Institute, University of California, San Francisco, CA 94158, United States
| | - David A Agard
- Department of Biochemistry & Biophysics, University of California, San Francisco, CA 94158, United States.
| |
Collapse
|
5
|
|
6
|
Abstract
Cryo-electron microscopy, or simply cryo-EM, refers mainly to three very different yet closely related techniques: electron crystallography, single-particle cryo-EM, and electron cryotomography. In the past few years, single-particle cryo-EM in particular has triggered a revolution in structural biology and has become a newly dominant discipline. This Review examines the fascinating story of its start and evolution over the past 40-plus years, delves into how and why the recent technological advances have been so groundbreaking, and briefly considers where the technique may be headed in the future.
Collapse
Affiliation(s)
- Yifan Cheng
- Howard Hughes Medical Institute, Department of Biochemistry and Biophysics, University of California, San Francisco, San Francisco, CA, USA
| |
Collapse
|
7
|
Robust image alignment for cryogenic transmission electron microscopy. J Struct Biol 2016; 197:279-293. [PMID: 28038834 DOI: 10.1016/j.jsb.2016.12.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Revised: 12/13/2016] [Accepted: 12/16/2016] [Indexed: 11/23/2022]
Abstract
Cryo-electron microscopy recently experienced great improvements in structure resolution due to direct electron detectors with improved contrast and fast read-out leading to single electron counting. High frames rates enabled dose fractionation, where a long exposure is broken into a movie, permitting specimen drift to be registered and corrected. The typical approach for image registration, with high shot noise and low contrast, is multi-reference (MR) cross-correlation. Here we present the software package Zorro, which provides robust drift correction for dose fractionation by use of an intensity-normalized cross-correlation and logistic noise model to weight each cross-correlation in the MR model and filter each cross-correlation optimally. Frames are reliably registered by Zorro with low dose and defocus. Methods to evaluate performance are presented, by use of independently-evaluated even- and odd-frame stacks by trajectory comparison and Fourier ring correlation. Alignment of tiled sub-frames is also introduced, and demonstrated on an example dataset. Zorro source code is available at github.com/CINA/zorro.
Collapse
|
8
|
Abstract
Until only a few years ago, single-particle electron cryo-microscopy (cryo-EM) was usually not the first choice for many structural biologists due to its limited resolution in the range of nanometer to subnanometer. Now, this method rivals X-ray crystallography in terms of resolution and can be used to determine atomic structures of macromolecules that are either refractory to crystallization or difficult to crystallize in specific functional states. In this review, I discuss the recent breakthroughs in both hardware and software that transformed cryo-microscopy, enabling understanding of complex biomolecules and their functions at atomic level.
Collapse
Affiliation(s)
- Yifan Cheng
- Department of Biochemistry and Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, USA.
| |
Collapse
|
9
|
Li X, Zheng SQ, Egami K, Agard DA, Cheng Y. Influence of electron dose rate on electron counting images recorded with the K2 camera. J Struct Biol 2013; 184:251-60. [PMID: 23968652 PMCID: PMC3854003 DOI: 10.1016/j.jsb.2013.08.005] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2013] [Revised: 08/12/2013] [Accepted: 08/13/2013] [Indexed: 11/24/2022]
Abstract
A recent technological breakthrough in electron cryomicroscopy (cryoEM) is the development of direct electron detection cameras for data acquisition. By bypassing the traditional phosphor scintillator and fiber optic coupling, these cameras have greatly enhanced sensitivity and detective quantum efficiency (DQE). Of the three currently available commercial cameras, the Gatan K2 Summit was designed specifically for counting individual electron events. Counting further enhances the DQE, allows for practical doubling of detector resolution and eliminates noise arising from the variable deposition of energy by each primary electron. While counting has many advantages, undercounting of electrons happens when more than one electron strikes the same area of the detector within the analog readout period (coincidence loss), which influences image quality. In this work, we characterized the K2 Summit in electron counting mode, and studied the relationship of dose rate and coincidence loss and its influence on the quality of counted images. We found that coincidence loss reduces low frequency amplitudes but has no significant influence on the signal-to-noise ratio of the recorded image. It also has little influence on high frequency signals. Images of frozen hydrated archaeal 20S proteasome (~700 kDa, D7 symmetry) recorded at the optimal dose rate retained both high-resolution signal and low-resolution contrast and enabled calculating a 3.6 Å three-dimensional reconstruction from only 10,000 particles.
Collapse
Affiliation(s)
- Xueming Li
- The Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
| | - Shawn Q. Zheng
- The Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
- The Howard Hughes Medical Institute, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
| | - Kiyoshi Egami
- The Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
- Graduate Group in Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
| | - David A. Agard
- The Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
- The Howard Hughes Medical Institute, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
| | - Yifan Cheng
- The Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California San Francisco, 600 16th Street, San Francisco, CA 94158, United States
| |
Collapse
|
10
|
Li X, Mooney P, Zheng S, Booth CR, Braunfeld MB, Gubbens S, Agard DA, Cheng Y. Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM. Nat Methods 2013; 10:584-90. [PMID: 23644547 PMCID: PMC3684049 DOI: 10.1038/nmeth.2472] [Citation(s) in RCA: 1389] [Impact Index Per Article: 126.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2012] [Accepted: 04/03/2013] [Indexed: 11/21/2022]
Abstract
In recent work with large high symmetry viruses, single particle electron cryomicroscopy (cryoEM) has reached the milestone of determining near atomic resolution structures by allowing direct fitting of atomic models into experimental density maps. However, achieving this goal with smaller particles of lower symmetry remains extraordinarily challenging. Using a newly developed single electron counting detector, we confirm that electron beam induced motion significantly degrades resolution and, importantly, show how the combination of rapid readout and nearly noiseless electron counting allow image blurring to be corrected to subpixel accuracy. Thus, intrinsic image information can be restored to high resolution (Thon rings visible to ~3 Å). Using this approach we determined a 3.3 Å resolution structure of a ~700 kDa protein with D7 symmetry showing clear side chain density. Our method greatly enhances image quality and data acquisition efficiency - key bottlenecks in applying near atomic resolution cryoEM to a broad range of protein samples.
Collapse
|
11
|
McLeod RA, Malac M. Characterization of detector modulation-transfer function with noise, edge, and holographic methods. Ultramicroscopy 2013; 129:42-52. [PMID: 23603855 DOI: 10.1016/j.ultramic.2013.02.021] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2012] [Revised: 02/18/2013] [Accepted: 02/22/2013] [Indexed: 11/12/2022]
Abstract
We developed a new method for characterization of detector performance used in the transmission electron microscope (TEM) based on the measured contrast of holographic fringes. The new method changes spatial frequency of the measured holographic fringes, generated by an electrostatic biprism and Schottky or cold field-emission gun, to sample the modulation-transfer function (MTF) of the detector. The MTF of a Gatan Ultrascan™ 1000 charged-coupled detector (CCD) is evaluated using the new method and the results are compared to the established noise and slanted-edge method results. Requirements for accuracy of the edge and noise MTF methods are discussed. We consider issues surrounding incomplete read-out and how it affects the gain reference normalization of the detector. We evaluate how the MTF affects optimization of experimental parameters in the TEM.
Collapse
Affiliation(s)
- Robert A McLeod
- Department of Physics, University of Alberta, Edmonton, Alberta, Canada.
| | | |
Collapse
|
12
|
Bui KH, Ishikawa T. 3D Structural Analysis of Flagella/Cilia by Cryo-Electron Tomography. Methods Enzymol 2013; 524:305-23. [DOI: 10.1016/b978-0-12-397945-2.00017-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
13
|
Niermann T, Lubk A, Röder F. A new linear transfer theory and characterization method for image detectors. Part I: Theory. Ultramicroscopy 2012; 115:68-77. [DOI: 10.1016/j.ultramic.2012.01.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Revised: 01/11/2012] [Accepted: 01/20/2012] [Indexed: 11/16/2022]
|
14
|
Lubk A, Röder F, Niermann T, Gatel C, Joulie S, Houdellier F, Magén C, Hÿtch MJ. A new linear transfer theory and characterization method for image detectors. Part II: experiment. Ultramicroscopy 2012; 115:78-87. [PMID: 22424716 DOI: 10.1016/j.ultramic.2012.01.011] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Revised: 01/13/2012] [Accepted: 01/20/2012] [Indexed: 10/14/2022]
Abstract
A novel generalized linear transfer theory describing the signal and noise transfer in image detectors has been developed in Part I (Niermann, this issue, [1]) of this paper. Similar to the existing notion of a point spread function (PSF) describing the transfer of the first statistical moment (the average), a noise spread function (NSF) was introduced to characterize the spatially resolved transfer of noise (central second moment, covariance). Following the theoretic results developed in Part I (Niermann, this issue, [1]), a new experimental method based on single spot illumination has been developed and applied to measure 2D point and 4D noise spread functions of CCD cameras used in TEM. A dedicated oversampling method has been used to suppress aliasing in the measured quantities. We analyze the 4D noise spread with respect to electronic and photonic noise contributions.
Collapse
Affiliation(s)
- Axel Lubk
- CEMES-CNRS 29, rue Jeanne Marvig B.P. 94347 F-31055 Toulouse Cedex, France.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Bammes BE, Rochat RH, Jakana J, Chen DH, Chiu W. Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency. J Struct Biol 2012; 177:589-601. [PMID: 22285189 DOI: 10.1016/j.jsb.2012.01.008] [Citation(s) in RCA: 95] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2011] [Revised: 12/21/2011] [Accepted: 01/11/2012] [Indexed: 11/28/2022]
Abstract
One limitation in electron cryo-microscopy (cryo-EM) is the inability to recover high-resolution signal from the image-recording media at the full-resolution limit of the transmission electron microscope. Direct electron detection using CMOS-based sensors for digitally recording images has the potential to alleviate this shortcoming. Here, we report a practical performance evaluation of a Direct Detection Device (DDD®) for biological cryo-EM at two different microscope voltages: 200 and 300 kV. Our DDD images of amorphous and graphitized carbon show strong per-pixel contrast with image resolution near the theoretical sampling limit of the data. Single-particle reconstructions of two frozen-hydrated bacteriophages, P22 and ε15, establish that the DDD is capable of recording usable signal for 3D reconstructions at about 4/5 of the Nyquist frequency, which is a vast improvement over the performance of conventional imaging media. We anticipate the unparalleled performance of this digital recording device will dramatically benefit cryo-EM for routine tomographic and single-particle structural determination of biological specimens.
Collapse
Affiliation(s)
- Benjamin E Bammes
- Graduate Program in Structural and Computational Biology and Molecular Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| | | | | | | | | |
Collapse
|
16
|
Niermann T, Park JB, Lehmann M. Local estimation of lattice constants in HRTEM images. Ultramicroscopy 2011; 111:1083-92. [PMID: 21740872 DOI: 10.1016/j.ultramic.2011.03.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2011] [Revised: 03/18/2011] [Accepted: 03/19/2011] [Indexed: 11/19/2022]
Abstract
A model-based approach to estimate lattice constants from an atomically resolved HRTEM image is presented. The approach only utilizes the inherent periodicity of these images and does not require a centrosymmetric structure of the specimen. This allows the evaluation of, for instance, wurtzite-based materials like InGaN/GaN heterostructures. The lattice constants are determined within precisions below 3 pm from areas only a few unit cells large. This makes this method suitable for further strain/compositional analysis. Furthermore, the impact of the approximations of the true detector's covariance matrices on the assessment of the model-based approach is investigated, and insights into the quality of these noise models of the detector are gained.
Collapse
Affiliation(s)
- T Niermann
- Institut für Optik und Atomare Physik, Technische Universität Berlin, Strasse des 17. Juni 135, 10623 Berlin, Germany.
| | | | | |
Collapse
|
17
|
Bammes BE, Rochat RH, Jakana J, Chiu W. Practical performance evaluation of a 10k × 10k CCD for electron cryo-microscopy. J Struct Biol 2011; 175:384-93. [PMID: 21619932 DOI: 10.1016/j.jsb.2011.05.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2011] [Revised: 05/09/2011] [Accepted: 05/10/2011] [Indexed: 11/18/2022]
Abstract
Electron cryo-microscopy (cryo-EM) images are commonly collected using either charge-coupled devices (CCD) or photographic film. Both film and the current generation of 16 megapixel (4k × 4k) CCD cameras have yielded high-resolution structures. Yet, despite the many advantages of CCD cameras, more than two times as many structures of biological macromolecules have been published in recent years using photographic film. The continued preference to film, especially for subnanometer-resolution structures, may be partially influenced by the finer sampling and larger effective specimen imaging area offered by film. Large format digital cameras may finally allow them to overtake film as the preferred detector for cryo-EM. We have evaluated a 111-megapixel (10k × 10k) CCD camera with a 9 μm pixel size. The spectral signal-to-noise ratios of low dose images of carbon film indicate that this detector is capable of providing signal up to at least 2/5 Nyquist frequency potentially retrievable for 3D reconstructions of biological specimens, resulting in more than double the effective specimen imaging area of existing 4k × 4k CCD cameras. We verified our estimates using frozen-hydrated ε15 bacteriophage as a biological test specimen with previously determined structure, yielding a ∼7 Å resolution single particle reconstruction from only 80 CCD frames. Finally, we explored the limits of current CCD technology by comparing the performance of this detector to various CCD cameras used for recording data yielding subnanometer resolution cryo-EM structures submitted to the electron microscopy data bank (http://www.emdatabank.org/).
Collapse
Affiliation(s)
- Benjamin E Bammes
- Graduate Program in Structural and Computational Biology and Molecular Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| | | | | | | |
Collapse
|
18
|
Abstract
Electron microscopy (EM) is an important tool for high-resolution structure determination in applications ranging from condensed matter to biology. Electronic detectors are now used in most applications in EM as they offer convenience and immediate feedback that is not possible with film or image plates. The earliest forms of electronic detector used routinely in transmission electron microscopy (TEM) were charge coupled devices (CCDs) and for many applications these remain perfectly adequate. There are however applications, such as the study of radiation-sensitive biological samples, where film is still used and improved detectors would be of great value. The emphasis in this review is therefore on detectors for use in such applications. Two of the most promising candidates for improved detection are: monolithic active pixel sensors (MAPS) and hybrid pixel detectors (of which Medipix2 was chosen for this study). From the studies described in this review, a back-thinned MAPS detector appears well suited to replace film in for the study of radiation-sensitive samples at 300 keV, while Medipix2 is suited to use at lower energies and especially in situations with very low count rates. The performance of a detector depends on the energy of electrons to be recorded, which in turn is dependent on the application it is being used for; results are described for a wide range of electron energies ranging from 40 to 300 keV. The basic properties of detectors are discussed in terms of their modulation transfer function (MTF) and detective quantum efficiency (DQE) as a function of spatial frequency.
Collapse
|
19
|
Clare DK, Orlova EV. 4.6A Cryo-EM reconstruction of tobacco mosaic virus from images recorded at 300 keV on a 4k x 4k CCD camera. J Struct Biol 2010; 171:303-8. [PMID: 20558300 PMCID: PMC2939825 DOI: 10.1016/j.jsb.2010.06.011] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2010] [Revised: 05/14/2010] [Accepted: 06/08/2010] [Indexed: 11/19/2022]
Abstract
Tobacco mosaic virus (TMV) is a plant virus with a highly ordered organisation and has been described in three different structural states: As stacked disks without RNA (X-ray crystallography), as a helical form with RNA (X-ray fibre diffraction) and as a second distinct helical form with RNA (cryo-EM). Here we present a structural analysis of TMV as a test object to assess the quality of cryo-EM images recorded at 300 keV on a CCD camera. The 4.6 Å TMV structure obtained is consistent with the previous cryo-EM structure and confirms that there is a second helical form of TMV. The structure here also shows that with a similar number of TMV segments an equivalent resolution can be achieved with a 4k CCD camera at 300 keV.
Collapse
|
20
|
Abstract
Single-particle electron microscopy (EM) can provide structural information for a large variety of biological molecules, ranging from small proteins to large macromolecular assemblies, without the need to produce crystals. The year 2008 has become a landmark year for single-particle EM as for the first time density maps have been produced at a resolution that made it possible to trace protein backbones or even to build atomic models. In this review, we highlight some of the recent successes achieved by single-particle EM and describe the individual steps involved in producing a density map by this technique. We also discuss some of the remaining challenges and areas, in which further advances would have a great impact on the results that can be achieved by single-particle EM.
Collapse
Affiliation(s)
- Yifan Cheng
- The W.M. Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California-San Francisco, CA 94158, USA.
| | | |
Collapse
|
21
|
McMullan G, Clark AT, Turchetta R, Faruqi AR. Enhanced imaging in low dose electron microscopy using electron counting. Ultramicroscopy 2009; 109:1411-6. [PMID: 19647366 PMCID: PMC2868354 DOI: 10.1016/j.ultramic.2009.07.004] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2009] [Revised: 06/24/2009] [Accepted: 07/07/2009] [Indexed: 10/26/2022]
Abstract
We compare the direct electron imaging performance at 120keV of a monolithic active pixel sensor (MAPS) operated in a conventional integrating mode with the performance obtained when operated in a single event counting mode. For the combination of sensor and incident electron energy used here, we propose a heuristic approach with which to process the single event images in which each event is renormalised to have an integrated weight of unity. Using this approach we find enhancements in the Nyquist frequency modulation transfer function (MTF) and detective quantum efficiency (DQE) over the corresponding integrating mode values by factors of 8 and 3, respectively.
Collapse
Affiliation(s)
- G McMullan
- MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 0QH, UK.
| | | | | | | |
Collapse
|
22
|
McMullan G, Chen S, Henderson R, Faruqi AR. Detective quantum efficiency of electron area detectors in electron microscopy. Ultramicroscopy 2009; 109:1126-43. [PMID: 19497671 PMCID: PMC2864625 DOI: 10.1016/j.ultramic.2009.04.002] [Citation(s) in RCA: 167] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2008] [Revised: 04/03/2009] [Accepted: 04/21/2009] [Indexed: 11/17/2022]
Abstract
Recent progress in detector design has created the need for a careful side-by-side comparison of the modulation transfer function (MTF) and resolution-dependent detective quantum efficiency (DQE) of existing electron detectors with those of detectors based on new technology. We present MTF and DQE measurements for four types of detector: Kodak SO-163 film, TVIPS 224 charge coupled device (CCD) detector, the Medipix2 hybrid pixel detector, and an experimental direct electron monolithic active pixel sensor (MAPS) detector. Film and CCD performance was measured at 120 and 300 keV, while results are presented for the Medipix2 at 120 keV and for the MAPS detector at 300 keV. In the case of film, the effects of electron backscattering from both the holder and the plastic support have been investigated. We also show that part of the response of the emulsion in film comes from light generated in the plastic support. Computer simulations of film and the MAPS detector have been carried out and show good agreement with experiment. The agreement enables us to conclude that the DQE of a backthinned direct electron MAPS detector is likely to be equal to, or better than, that of film at 300 keV.
Collapse
Affiliation(s)
- G McMullan
- MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB20QH, UK.
| | | | | | | |
Collapse
|
23
|
Maki-Yonekura S, Yonekura K. Electron digital imaging toward high-resolution structure analysis of biological macromolecules. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2008; 14:362-369. [PMID: 18598572 DOI: 10.1017/s1431927608080665] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Digital imaging has been applied to structure analysis of biological macromolecules in combination with electron energy filtering. Energy filtering can improve the image contrast of frozen-hydrated specimens, but needs a high-sensitivity imaging device instead of photographic film, because of a decrease in electrons after filtration. Here, a lens-coupled slow-scan charge-coupled device (SSCCD) camera with a post-column-type energy filter were examined to image bacterial flagellar filaments embedded in ice. We first measured the modulation transfer function of this camera and showed the remarkable improvement, compared to other fiber-coupled SSCCD cameras. The 3D structure calculated at approximately 7-angstroms resolution clearly resolves alpha-helices. Furthermore, filtered datasets recorded on the SSCCD camera with liquid-nitrogen and liquid-helium cooling were compared with the previous unfiltered one on film with liquid-helium cooling. This report describes the suitability of digital imaging with energy filtering for higher-resolution structure studies from its practical application.
Collapse
Affiliation(s)
- Saori Maki-Yonekura
- The W. M. Keck Advanced Microscopy Laboratory, Department of Biochemistry and Biophysics, University of California, San Francisco, 1700 4th Street, San Francisco, CA 94158-2532, USA
| | | |
Collapse
|
24
|
Stagg SM, Lander GC, Quispe J, Voss NR, Cheng A, Bradlow H, Bradlow S, Carragher B, Potter CS. A test-bed for optimizing high-resolution single particle reconstructions. J Struct Biol 2008; 163:29-39. [PMID: 18534866 DOI: 10.1016/j.jsb.2008.04.005] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2007] [Revised: 03/04/2008] [Accepted: 04/01/2008] [Indexed: 01/08/2023]
Abstract
It is becoming routine for cryoEM single particle reconstructions to result in 3D electron density maps with resolutions of approximately 10A, but maps with resolutions of 5A or better are still celebrated events. The electron microscope has a resolving power to better than 2A, and thus should not be a limiting factor; instead the practical limitations in resolution most likely arise from a combination of specimen preparation methods, data collection parameters, and data analysis procedures. With the aid of a highly automated system for acquiring images, coupled to a relational database to keep track of all processing parameters, we have taken a systematic approach to optimizing parameters affecting the resolution of single particle reconstructions. Using GroEL as a test-bed, we performed a series of 3D reconstructions where we systematically varied the number of particles used in computing the map, the accelerating voltage of the microscope, and the electron dose used to acquire the images. We also investigated methods for excluding unacceptable or "bad" particles from contributing to the final 3D map. Using relatively standard instrumentation (Tecnai F20, 4K x 4K CCD, side entry cold stage) and a completely automated approach, these approaches resulted in a map with a nominal resolution of 5.4A (FSC(0.5)) in which secondary structure is clearly discernable and the handedness of some of the alpha-helices in the GroEL structure can be determined.
Collapse
Affiliation(s)
- Scott M Stagg
- The National Resource for Automated Molecular Microscopy, Department of Cell Biology, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA 92037, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Chen DH, Jakana J, Liu X, Schmid MF, Chiu W. Achievable resolution from images of biological specimens acquired from a 4k x 4k CCD camera in a 300-kV electron cryomicroscope. J Struct Biol 2008; 163:45-52. [PMID: 18514542 DOI: 10.1016/j.jsb.2008.04.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2007] [Revised: 04/01/2008] [Accepted: 04/07/2008] [Indexed: 11/29/2022]
Abstract
Bacteriorhodopsin and epsilon 15 bacteriophage were used as biological test specimens to evaluate the potential structural resolution with images captured from a 4k x 4k charge-coupled device (CCD) camera in a 300-kV electron cryomicroscope. The phase residuals computed from the bacteriorhodopsin CCD images taken at 84,000x effective magnification averaged 15.7 degrees out to 5.8-A resolution relative to Henderson's published values. Using a single-particle reconstruction technique, we obtained an 8.2-A icosahedral structure of epsilon 15 bacteriophage with the CCD images collected at an effective magnification of 56,000x. These results demonstrate that it is feasible to retrieve biological structures to a resolution close to 2/3 of the Nyquist frequency from the CCD images recorded in a 300-kV electron cryomicroscope at a moderately high but practically acceptable microscope magnification.
Collapse
Affiliation(s)
- Dong-Hua Chen
- National Center for Macromolecular Imaging, Verna and Marrs McLean Department of Biochemistry and Molecular Biology, Baylor College of Medicine, One Baylor Plaza, Houston, TX 77030, USA
| | | | | | | | | |
Collapse
|
26
|
Downing KH, Mooney PE. A charge coupled device camera with electron decelerator for intermediate voltage electron microscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:043702. [PMID: 18447528 PMCID: PMC2678785 DOI: 10.1063/1.2902853] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2008] [Accepted: 03/06/2008] [Indexed: 05/26/2023]
Abstract
Electron microscopists are increasingly turning to intermediate voltage electron microscopes (IVEMs) operating at 300-400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions, CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single particle reconstruction of protein structures, tomographic studies of cell ultrastructure, and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels.
Collapse
Affiliation(s)
- Kenneth H Downing
- Life Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, USA.
| | | |
Collapse
|
27
|
Marsh MP, Chang JT, Booth CR, Liang NL, Schmid MF, Chiu W. Modular software platform for low-dose electron microscopy and tomography. J Microsc 2007; 228:384-9. [PMID: 18045333 PMCID: PMC4384816 DOI: 10.1111/j.1365-2818.2007.01856.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Transmission electron microscopy imaging protocols required by structural scientists vary widely and can be laborious without tailor-made applications. We present here the jeol automated microscopy expert system (james) api integrator, a programming library for computer control of transmission electron microscopy operations and equipment. james has been implemented on JEOL microscopes with Gatan CCDs but is designed to be modular so it can be adapted to run on different microscopes and detectors. We have used the james api integrator to develop two applications for low-dose digital imaging: james imaging application and the mr t tomographic imaging application. Both applications have been widely used within our NCRR-supported Center for routine data collection and are now made available for public download.
Collapse
Affiliation(s)
- Michael P Marsh
- Graduate Program in Structural and Computational Biology and Molecular Biophysics, and National Center for Macromolecular Imaging, #Verna and Marrs McLean Department of Biochemistry and Molecular Biology, Baylor College of Medicine, Houston, TX 77030, USA
| | | | | | | | | | | |
Collapse
|