1
|
Mansour MM, Moussa SM, Meheissen MA, Aboelseoud MR. Bacterial sealing ability of calcium silicate-based sealer for endodontic surgery: an in-vitro study. BMC Oral Health 2024; 24:584. [PMID: 38773504 PMCID: PMC11107006 DOI: 10.1186/s12903-024-04309-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Accepted: 04/29/2024] [Indexed: 05/23/2024] Open
Abstract
BACKGROUND Apical surgery with standard retrograde maneuvers may be challenging in certain cases. Simplifying apical surgery to reduce operating time and streamline retrograde manipulation is an emerging need in clinical endodontics. AIM OF THE STUDY The aim of the study was to compare the bacterial sealing ability of a calcium silicate-based sealer with the single cone technique combined with root end resection only, and calcium silicate-based sealer as a retrograde filling versus MTA retrofilling, and to analyze bacterial viability using confocal laser scanning microscope (CLSM). MATERIALS AND METHODS In this in vitro experimental study, 50 extracted human maxillary incisor teeth were instrumented and randomly divided into five groups: three experimental groups, a positive control group, and a negative control group (n = 10/group). In the experimental groups, the roots were obturated using the single cone technique (SCT) and a calcium silicate-based sealer. In group 1, the roots were resected 3 mm from the apex with no further retrograde preparation or filling. In groups 2 and 3, the roots were resected, retroprepared, and retrofilled with either a calcium silicate-based sealer or MTA, respectively. Group 4 (positive control) was filled with a single gutta-percha cone without any sealer. In group 5 (negative control), the canals were left empty, and the roots were sealed with wax and nail varnish. A bacterial leakage model using Enterococcus faecalis was employed to assess the sealing ability over a 30-day period, checking for turbidity and analyzing colony forming units (CFUs) per milliliter. Five specimens from each group were examined using CLSM for bacterial viability. Data for the bacterial sealing ability were statistically analyzed using chi-squared and Kruskal-Wallis tests. RESULTS The three experimental groups did not show significant differences in terms of bacterial leakage, or bacterial counts (CFUs) (P > 0.05). However, significant differences were observed when comparing the experimental groups to the positive control group. Notably, the calcium silicate-based sealer, when used as a retrofilling, yielded the best sealing ability. CLSM imaging revealed viable bacterial penetration in all the positive control group specimens while for the experimental groups, dead bacteria was the prominent feature seen. CONCLUSION Within the limitations of this study, it could be concluded that the bacterial sealing ability of calcium silicate-based sealer with the single cone technique combined with root end resection only and calcium silicate-based sealer as a retrograde filling were comparable with MTA retrofilling during endodontic surgical procedures.
Collapse
Affiliation(s)
- Mai M Mansour
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, 21527, Egypt.
| | - Sybel M Moussa
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, 21527, Egypt
| | - Marwa A Meheissen
- DMedical Microbiology & Immunology, Faculty of Medicine, Alexandria University, Alexandria, 21527, Egypt
| | - Mahmoud R Aboelseoud
- Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, 21527, Egypt
| |
Collapse
|
2
|
Zogheib C, Roumi R, Baldi A, Palopoli P, Pasqualini D, Berutti E, Alovisi M. The effect of ultrasonic access cavity preparation on dentinal inner walls: a micro-CT study on cadaveric samples. Oral Radiol 2023; 39:639-645. [PMID: 37000330 DOI: 10.1007/s11282-023-00680-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 03/02/2023] [Indexed: 04/01/2023]
Abstract
OBJECTIVE The objective of this study is to evaluate the occurrence of coronal dentinal micro-cracks after access cavity refinement using high-speed burs and ultrasonic tips by means of micro-computed tomography (micro-CT) analysis. METHODS In this study, 18 mandibular cadaveric incisors were divided into two groups according to the protocol of the preparation of the conventional access cavity. The diamond bur 802 # 12 was used until the perforation of the pulp roof. Then, the Endo-Z bur was used for the group #1 and the ultrasonic tip Start-X # 1 for the group #2 to finish and refine the access cavity. The preparation time of each access cavity has been recorded. The teeth underwent a micro-CT scan before and after the preparation of the access cavity. Fisher's exact test, the Chi-square test, the Kolmogorov-Smirnov test, the Mann-Whitney test, and the Student's test were used for statistical evaluation. RESULTS The percentage of teeth with new micro-cracks is not significantly different between the two groups (-p-value < 0.5). The number of newly formed micro-cracks and extension size were not significantly different between the two groups. The direction of extension of the micro- cracks was occluso-apical. The average duration of the access cavity is significantly smaller with the Endo-Z system (-p- value < 0.001). The roughness of walls surfaces has no statistically difference between the two groups. CONCLUSION The use of ultrasound, although slower, is considered safe in the creation of dentinal micro-cracks, in the preparation of the access cavity.
Collapse
Affiliation(s)
- C Zogheib
- Department of Endodontics, Saint Joseph University of Beirut, Beirut, Lebanon
| | - R Roumi
- Department of Endodontics, Saint Joseph University of Beirut, Beirut, Lebanon
| | - A Baldi
- Department of Surgical Sciences, Dental School, Endodontics, University of Turin, Turin, Italy
| | | | - D Pasqualini
- Department of Surgical Sciences, Dental School, Endodontics, University of Turin, Turin, Italy
| | - E Berutti
- Department of Surgical Sciences, Dental School, Endodontics, University of Turin, Turin, Italy
| | - M Alovisi
- Department of Surgical Sciences, Dental School, Endodontics, University of Turin, Turin, Italy
| |
Collapse
|
3
|
John J, Singh V P P, Karuveettil V, M R, Subramanian D, Haridas K. Comparison of crack formation induced by ultrasonic tips and burs during root-end preparation: a systematic review and meta-analysis. Evid Based Dent 2022:10.1038/s41432-022-0823-0. [PMID: 36434118 DOI: 10.1038/s41432-022-0823-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Accepted: 12/02/2021] [Indexed: 06/16/2023]
Abstract
Introduction The main objective of root canal treatment is to achieve apical seal. Crack formation during root-end preparation promotes bacterial penetration, thereby leading to failure. This systematic review aims to examine the literature and summarise studies that compare the crack formation induced by ultrasonic tips and burs during root-end preparation.Methods This systematic review and meta-analysis were reported and conducted according to the PRISMA guidelines. The online databases PubMed, Scopus, and Google Scholar were used for data search. In vitro and ex vivo studies conducted up to March 2021 in the English language were included in the review. The risk of bias in the present study was assessed using a customised tool. A random-effects model was used for meta-analysis, χ² values and I² values were used to assess statistical heterogeneity. Meta-analysis was performed using RevMan software Version 5.4.Results A total of 317 records were found from all of the databases and one article was added following hand-searching. Twelve articles were included in the study after the application of the eligibility criteria of which ten articles were included for the meta-analysis. Nine studies showed a medium risk of bias while three studies showed a high risk of bias. The analysis of the crack formation showed a statistically significant difference between the ultrasonic tip and the bur (P = 0.0002). The odds ratio was 2.72 (1.60, 4.65) with a confidence interval of 95% suggesting higher odds of crack formation in the ultrasonic group.Conclusion This review concludes that ultrasonic root-end preparation resulted in higher crack formation than burs.
Collapse
Affiliation(s)
- Jesseca John
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India.
| | - Prabath Singh V P
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Vineetha Karuveettil
- Department of Public Health Dentistry, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Remya M
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Deepthy Subramanian
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| | - Kaushik Haridas
- Department of Conservative Dentistry and Endodontics, Amrita School of Dentistry, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India
| |
Collapse
|
4
|
Setzer FC, Kratchman SI. Present Status and Future Directions - Surgical Endodontics. Int Endod J 2022; 55 Suppl 4:1020-1058. [PMID: 35670053 DOI: 10.1111/iej.13783] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/30/2022] [Accepted: 05/31/2022] [Indexed: 11/29/2022]
Abstract
Endodontic surgery encompasses several procedures for the treatment of teeth with a history of failed root canal treatment, such as root-end surgery, crown- and root resections, surgical perforation repair, and intentional replantation. Endodontic microsurgery is the evolution of the traditional apicoectomy techniques and incorporates high magnification, ultrasonic root-end preparation and root-end filling with biocompatible filling materials. Modern endodontic surgery uses the dental operating microscope, incorporates cone-beam computed tomography (CBCT) for preoperative diagnosis and treatment planning, and has adopted piezoelectric approaches to osteotomy and root manipulation. Crown- and root resection techniques have benefitted from the same technological advances. This review focuses on the current state of root-end surgery by comparing the techniques and materials applied during endodontic microsurgery to the most widely used earlier methods and materials. The most recent additions to the clinical protocol and technical improvements are discussed, and an outlook on future directions is given. While non-surgical retreatment remains the first choice to address most cases with a history of endodontic failure, modern endodontic microsurgery has become a predictable and minimally invasive alternative for the retention of natural teeth.
Collapse
Affiliation(s)
- F C Setzer
- Department of Endodontics, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| | - S I Kratchman
- Department of Endodontics, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States of America
| |
Collapse
|
5
|
Bijari S, Saberi E, Dinarvand R. Scanning electron microscopic evaluation of the effect of different root-end resection methods in the crack formation in root canals filled with mineral trioxide aggregate or calcium-enriched mixture cement. Dent Res J (Isfahan) 2022. [DOI: 10.4103/1735-3327.363569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
|
6
|
Heberer MT, Roggendorf HC, Faber FJ, Lawrenz NA, Frankenberger R, Roggendorf MJ. Longitudinal craze line propagation in human root dentin after instrumentation with NiTi rotary files of different instrument tapers after long-term chewing simulation. Clin Oral Investig 2021; 26:2671-2679. [PMID: 34787719 PMCID: PMC8898247 DOI: 10.1007/s00784-021-04238-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 10/15/2021] [Indexed: 11/26/2022]
Abstract
Objectives The aim of this study was to investigate whether file design and taper significantly influence microcrack initiation during machine preparation. Materials and methods Sixty extracted teeth with straight single canals were selected. The teeth were randomly assigned to four groups based on their root canal anatomy and the corresponding NiTi rotary file system (I, Mtwo; II, ProTaper Universal; III, F6 SkyTaper; control, no preparation and filling). The root canals of the experimental groups were filled using the single-cone technique. The tested teeth were all subjected to a mechanical chewing simulation with flat lead loading over a period of 3 years (corresponding to 150,000 cycles). The teeth were checked for dentinal defects (accumulative crack growth in length) under the digital microscope (Keyence VHX-5000) at time 0 (baseline prior to chewing simulation) and after 3, 6, 12, 24, and 36 months of loading. The cumulative crack increase was statistically analyzed using the Kruskal–Wallis test, Jonckheere–Terpstra test, and the Wilcoxon rank-sum test. The significance was set at p < 0.05. Results In contrast to preparation with greater-tapered instruments, ProTaper Universal (group II) and F6 SkyTaper (group III) instrumentation with the smaller tapered Mtwo files (group I) showed less accumulative propagation of craze lines (p < 0.05) at all time points. Conclusion Instruments with greater taper for root canal instrumentation should be used with care to avoid negative long-term effects in the form of propagation of dentinal defects over time. A positive cutting-edge angle and a smaller taper have a positive effect on a lower craze line development. Clinical relevance Instruments with a positive cutting-edge angle and a smaller taper are beneficial for the long-term preservation of dentinal tooth structure.
Collapse
Affiliation(s)
- Marie-Therese Heberer
- Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Philipps University Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg-Voigt-Straße 3, 35039, Marburg, Germany.
| | - Hubert C Roggendorf
- Interdisciplinary Department of Oral Surgery an Implantology, University of Cologne, Kerpener Straße 32, 50931, Cologne, Germany
| | - Franz-Josef Faber
- Pre-Clinical Department, University of Cologne, Kerpener Straße 32, 50931, Cologne, Germany
| | - Nicolai-Alexander Lawrenz
- Department of Mathematics and Computer Science, Philipps University of Marburg, Hans-Meerwein-Straße 6, 35043, Marburg, Germany
| | - Roland Frankenberger
- Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Philipps University Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg-Voigt-Straße 3, 35039, Marburg, Germany
| | - Matthias J Roggendorf
- Department of Operative Dentistry, Endodontics, and Pediatric Dentistry, Philipps University Marburg and University Hospital Giessen and Marburg, Campus Marburg, Georg-Voigt-Straße 3, 35039, Marburg, Germany
| |
Collapse
|
7
|
Zogheib C, Roumi R, Bourbouze G, Naaman A, Khalil I, Plotino G. Effects of ultrasonic refinement on endodontic access cavity walls: A microcomputed tomography analysis. J Conserv Dent 2021; 24:29-35. [PMID: 34475676 PMCID: PMC8378494 DOI: 10.4103/jcd.jcd_599_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 12/16/2020] [Accepted: 02/09/2021] [Indexed: 11/04/2022] Open
Abstract
Objectives The present study aimed in assessing the coronal defects after access cavity finishing and refinement by micro. Methods Access cavities on thirty molars were prepared using a diamond bur. To finish and refine the access cavity, the Endo-Z was used in group 1 (n=15) and Start X 1 in group 2. Preparation time was recorded. A micro-CT scan was done before and after access preparation. Formation and location of the new defects were registered, the extension of defects calculated and the direction of the extension registered, preparation time and surface roughness determined (P < 0.05). Results Preparation time was significantly higher with ultrasonics (P <0.001). Internal walls showed smoother surfaces for Endo-Z group. Newly counts and extension length of defects weren't significantly different between groups (P > .05). Conclusion Ultrasonic tips induced new cracks. Both instruments caused the extension of cracks. Ultrasonic tips requires more time and results in significantly rougher surfaces.
Collapse
Affiliation(s)
- Carla Zogheib
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, Beirut, Lebanon
| | - Reina Roumi
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, Beirut, Lebanon
| | | | - Alfred Naaman
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, Beirut, Lebanon
| | - Issam Khalil
- Department of Endodontics, Faculty of Dentistry, Saint Joseph University, Beirut, Lebanon
| | | |
Collapse
|
8
|
Campello AF, Marceliano-Alves MF, Provenzano JC, Loyola SC, Siqueira JF, Machado AG, Machado AL, Lopes RT, Paiva MM, Alves FRF. Accuracy of Microcomputed Tomography in Detecting Dentinal Cracks: A Correlative Study with Scanning Electron and Operative Microscopy. SCANNING 2021; 2021:5571123. [PMID: 34104287 PMCID: PMC8143888 DOI: 10.1155/2021/5571123] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Accepted: 05/03/2021] [Indexed: 05/13/2023]
Abstract
The aim of the study was to evaluate the accuracy of microcomputed tomography (mCT) to detect dentinal cracks when compared with scanning electron microscopy (SEM) and operating microscopy (OM). Different conditions of pixel size (10 or 17 μm), sample moisture (dry/moist), and transillumination (with/without) were evaluated. Additionally, the influence of the dentinal defect width on its detection was analyzed. The root canals of human mandibular incisors were prepared with the Reciproc R40 instrument (VDW, Munich, Germany). The roots were sectioned 5 and 10 mm from the apex, and mCT scans of middle and apical segments were performed at two pixel sizes: 10 μm and 17 μm, under dry and moist conditions (groups: 10dry, 10moist, 17dry, and 17moist). The operating microscope was used with and without transillumination (groups: OMTrans and OM). Findings showed that accuracy was moderate for the 10dry, 10moist, and OMTrans groups, poor for OM and very poor for 17dry and 17moist. The thickness of the dentin crack significantly influenced its detection by mCT using the resolution of 10 μm in both dry and wet conditions (P = .002), 17 μm in the dry condition (P = .002), and by the operating microscope using transillumination (P = .009). Some cracks visualized in SEM were not detected by mCT and an operating microscope. Not only the mCT resolution but also the sample moisture condition and the dentinal crack width can significantly influence its detection.
Collapse
Affiliation(s)
| | | | | | - Simone C. Loyola
- Faculty of Dentistry, Iguaçu University, Nova Iguaçu, RJ, Brazil
| | - José F. Siqueira
- Faculty of Dentistry, Iguaçu University, Nova Iguaçu, RJ, Brazil
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Duque de Caxias, RJ, Brazil
| | - André G. Machado
- Faculty of Dentistry, Iguaçu University, Nova Iguaçu, RJ, Brazil
| | - André L. Machado
- Faculty of Dentistry, Iguaçu University, Nova Iguaçu, RJ, Brazil
| | - Ricardo T. Lopes
- Department of Nuclear Energy, Rio de Janeiro Federal University, Rio de Janeiro, RJ, Brazil
| | | | - Flávio R. F. Alves
- Faculty of Dentistry, Iguaçu University, Nova Iguaçu, RJ, Brazil
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Duque de Caxias, RJ, Brazil
| |
Collapse
|
9
|
Sachdeva N, Nikhil V, Jha P. Effect of ultrasonic root-end cavity preparation on dentinal microcrack formation: A micro-computed tomography study. J Conserv Dent 2019; 22:362-366. [PMID: 31802820 PMCID: PMC6873600 DOI: 10.4103/jcd.jcd_67_19] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Background: Root-end preparation during surgical endodontics may produce dentinal microcrack formation and/or propagation, leading to vertical root fractures. Aim: This study aimed to evaluate and compare the microcrack formation and propagation during ultrasonic root-end cavity preparation, with diamond- and zirconium nitride-coated tips using micro-computed tomography (CT). Methodology: Twenty-eight extracted, mature, free-of-defect, mandibular premolars were decoronated and micro-CT scanned for the presence of preexisting microcracks. Samples were prepared till F4, were obturated, and were re-scanned to determine an increase in the number of microcracks. After 3 mm of root-end resection, the samples were randomly divided for ultrasonic root-end preparation into Group 1 (n = 12): preparation was done with ProUltra Surg tip, Group 2 (n = 12): preparation was done with KiS tip, and Group 3 (n = 4): no preparation was done. The samples were rescanned, and data collected were analyzed using ANOVA and Student's t-test. The level of significance was set at 5%. Results: Preexisting microcracks were observed in few samples. The mean percentage number increase of microcracks after root-end preparation in ProUltra Surg group was 1.25 and in KiS group, it was 0.5. The difference in mean percentage increase for the number of microcracks after root-end cavity preparation using ProUltra Surg tip and KiS tip was 0.75. However, this difference was not statistically significant (P = 0.34). Conclusion: Both diamond- and zirconium nitride-coated ultrasonic tips resulted in more number of dentinal crack formation and propagation when preexisting cracks were present.
Collapse
Affiliation(s)
- Naina Sachdeva
- Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| | - Vineeta Nikhil
- Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| | - Padmanabh Jha
- Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| |
Collapse
|
10
|
Rashed B, Iino Y, Ebihara A, Okiji T. Evaluation of Crack Formation and Propagation with Ultrasonic Root-End Preparation and Obturation Using a Digital Microscope and Optical Coherence Tomography. SCANNING 2019; 2019:5240430. [PMID: 31969970 PMCID: PMC6955132 DOI: 10.1155/2019/5240430] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 12/19/2019] [Indexed: 05/21/2023]
Abstract
OBJECTIVE This study is aimed at determining (1) the effect of root-end resection, ultrasonic root-end preparation, and root-end filling on the incidence of crack formation and propagation by using a digital microscope (DM) and optical coherence tomography (OCT) and (2) the performance of OCT on the detection of cracks by comparing with microcomputed tomography (micro-CT) as a reference standard. METHODOLOGY Thirty extracted lower incisors were endodontically treated and subjected to root-end resection and ultrasonic root-end cavity preparation. Then, the teeth were divided into three groups (n = 10, each), and the root-end cavity was either left unfilled or filled with mineral trioxide aggregate (MTA) or super-EBA. The resected surface was observed with OCT and DM after the root-end resection, ultrasonic root-end preparation, and root-end filling, and the frequency of incomplete and complete cracks were recorded. The observation was repeated after two weeks, one month, and two months, and micro-CT scans after two months were taken as the gold standard. RESULTS The DM results show dentinal crack formation in 47% of the samples following root-end resection and in 87% following ultrasonic preparation. After the ultrasonic preparation, no existing crack propagated to a complete crack, but new cracks were formed. MTA and super-EBA had no effect on crack formation. The Spearman correlation coefficient between OCT and DM was 0.186 (very weak correlation; p = 0.015). Sensitivity and specificity in comparison to micro-CT were 0.50 and 0.55 in OCT and 1.00 and 0.35 in DM, respectively. McNemar's test showed a significant difference between OCT and DM (p < 0.05). CONCLUSION Apical resection and ultrasonic preparation could form dentinal cracks. OCT and DM showed different detection frequencies of cracks with very weak correlation. DM showed superior sensitivity compared with OCT.
Collapse
Affiliation(s)
- Bayan Rashed
- Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
- King Abdul-Aziz Airbase Hospital, Dhahran, Saudi Arabia
| | - Yoshiko Iino
- Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - Arata Ebihara
- Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| | - Takashi Okiji
- Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan
| |
Collapse
|
11
|
Crack Formation Following Root-End Preparation in Roots with the Butterfly Effect. Eur Endod J 2018; 3:107-112. [PMID: 32161865 PMCID: PMC7006567 DOI: 10.14744/eej.2018.47965] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Revised: 06/18/2018] [Accepted: 06/16/2018] [Indexed: 11/20/2022] Open
Abstract
Objective: To investigate apical cracks in roots that exhibit the butterfly effect and that have undergone apical resection and ultrasonic root-end cavity preparation. The effect of the obturation material was also studied. Methods: Forty extracted single-rooted teeth were decoronated at the cemento-enamel junction. Roots were viewed under a light microscope and coded according to the presence or absence of the butterfly effect. Canals were prepared using ProTaper Next instruments to size X3 and assigned to two obturation groups (gutta-percha and AH Plus, and ProRoot MTA alone). Each contained twenty roots (10 with the butterfly effect and 10 without the butterfly effect). Roots were resected perpendicular to their long axis, 3 mm from the apex, and cavities were cut using ultrasonic retrotips. Resin replicas were used for crack imaging from scanning electron micrographs. Statistical analyses were performed using Stata 13.1 (StataCorp, College Station, TX, USA). Results: Cracks occurred more frequently in teeth with the butterfly effect (80%), with this difference being significant (P=0.001). Most cracks (73%) ran buccolingually. Teeth obturated with MTA developed fewer cracks compared to those obturated with GP and sealer. Conclusion: Root-ends with the butterfly effect had a significantly higher number of buccolingual cracks following resection and ultrasonic root-end preparation. This might explain the development of some vertical root fractures, which usually run buccolingually. Canal obturation with MTA may be protective.
Collapse
|
12
|
Li ML, Liao WL, Cai HX. A micro-computed tomographic evaluation of dentinal microcrack alterations during root canal preparation using single-file Ni-Ti systems. Exp Ther Med 2017; 15:494-499. [PMID: 29387202 PMCID: PMC5769226 DOI: 10.3892/etm.2017.5399] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Accepted: 10/26/2017] [Indexed: 12/05/2022] Open
Abstract
The aim of the present study was to evaluate the length of dentinal microcracks observed prior to and following root canal preparation with different single-file nickel-titanium (Ni-Ti) systems using micro-computed tomography (micro-CT) analysis. A total of 80 mesial roots of mandibular first molars presenting with type II Vertucci canal configurations were scanned at an isotropic resolution of 7.4 µm. The samples were randomly assigned into four groups (n=20 per group) according to the system used for root canal preparation, including the WaveOne (WO), OneShape (OS), Reciproc (RE) and control groups. A second micro-CT scan was conducted after the root canals were prepared with size 25 instruments. Pre- and postoperative cross-section images of the roots (n=237,760) were then screened to identify the lengths of the microcracks. The results indicated that the microcrack lengths were notably increased following root canal preparation (P<0.05). The alterations in microcrack length in the OS group were more significant compared with those in the WO, RE and control groups (P<0.05). In conclusion, the formation and development of dentinal microcracks may be associated with the movement caused by preparation rather than the taper of the files. Among the single-file Ni-Ti systems, WO and RE were not observed to cause notable microcracks, while the OS system resulted in evident microcracks.
Collapse
Affiliation(s)
- Mei-Lin Li
- Department of Oral Medicine, Haizhu Square Branch, Stomatological Hospital, Southern Medical University (Guangdong Provincial Stomatological Hospital), Guangzhou, Guangdong 510280, P.R. China
| | - Wei-Li Liao
- Zhujiang New Town Dental Clinic, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, Guangdong 510060, P.R. China
| | - Hua-Xiong Cai
- Zhujiang New Town Dental Clinic, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-Sen University, Guangzhou, Guangdong 510060, P.R. China
| |
Collapse
|
13
|
Aydemir S, Arukaslan G, Sarıdağ S, Kaya-Büyükbayram I, Ylıdıran Y. Comparing Fracture Resistance and the Time Required for Two Different Fiber Post Removal Systems. J Prosthodont 2017; 27:771-774. [DOI: 10.1111/jopr.12575] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/28/2016] [Indexed: 11/30/2022] Open
Affiliation(s)
- Seda Aydemir
- Department of Endodontics; Kocaeli University Faculty of Dentistry; Kocaeli Turkey
| | - Göze Arukaslan
- Department of Endodontics; Kocaeli University Faculty of Dentistry; Kocaeli Turkey
| | - Serkan Sarıdağ
- Department of Prosthodontics; Kocaeli University Faculty of Dentistry; Kocaeli Turkey
| | - Işıl Kaya-Büyükbayram
- Department of Endodontics; Istanbul Aydin University Faculty of Dentistry; Istanbul Turkey
| | - Yasemin Ylıdıran
- Department of Mechanical Engineering; Kocaeli University Faculty of Dentistry; Kocaeli Turkey
| |
Collapse
|
14
|
Hülsmann M, Tulus G. Non-surgical retreatment of teeth with persisting apical periodontitis following apicoectomy: decision making, treatment strategies and problems, and case reports. ACTA ACUST UNITED AC 2016. [DOI: 10.1111/etp.12098] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
15
|
Periapical Bone Healing after Apicectomy with and without Retrograde Root Filling with Mineral Trioxide Aggregate: A 6-year Follow-up of a Randomized Controlled Trial. J Endod 2016; 42:533-7. [DOI: 10.1016/j.joen.2016.01.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2015] [Revised: 01/11/2016] [Accepted: 01/12/2016] [Indexed: 01/26/2023]
|
16
|
Kwak SW, Moon YM, Yoo YJ, Baek SH, Lee W, Kim HC. Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study. Restor Dent Endod 2014; 39:276-81. [PMID: 25383346 PMCID: PMC4223097 DOI: 10.5395/rde.2014.39.4.276] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Accepted: 06/13/2014] [Indexed: 11/11/2022] Open
Abstract
Objectives The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods The apical 3-mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.
Collapse
Affiliation(s)
- Sang-Won Kwak
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| | - Young-Mi Moon
- Department of Conservative Dentistry, School of Dentistry, Daejeon Hospital, WonKwang University, Daejeon, Korea
| | - Yeon-Jee Yoo
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
| | - Seung-Ho Baek
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
| | - WooCheol Lee
- Department of Conservative Dentistry, School of Dentistry, Seoul National University, Dental Research Institute, Seoul, Korea
| | - Hyeon-Cheol Kim
- Department of Conservative Dentistry, School of Dentistry, Pusan National University, Dental Research Institute, Yangsan, Korea
| |
Collapse
|
17
|
Aydemir S, Cimilli H, Mumcu G, Chandler N, Kartal N. Crack Formation on Resected Root Surfaces Subjected to Conventional, Ultrasonic, and Laser Root-End Cavity Preparation. Photomed Laser Surg 2014; 32:351-5. [DOI: 10.1089/pho.2013.3696] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Seda Aydemir
- Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey
| | - Hale Cimilli
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey
| | - Gonca Mumcu
- Faculty of Health Sciences, Marmara University, Istanbul, Turkey
| | - Nicholas Chandler
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Nevin Kartal
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkey
| |
Collapse
|
18
|
Aydemir S, Cimilli H, Yoruç ABH, Kartal N. Evaluation of two different root-end cavity preparation techniques: A scanning electron microscope study. Eur J Dent 2013; 7:186-190. [PMID: 24883024 PMCID: PMC4023193 DOI: 10.4103/1305-7456.110168] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE In this study, we aimed to evaluate and compare the dentinal walls of root-end cavities for the presence of cracks after cavity preparation using US retrotips and Er: YAG laser. MATERIALS AND METHODS Fifty single-rooted teeth were prepared by Protaper NiTi rotary system and obturated by lateral condensation. Three milimeters of root-end was resected. Twenty teeth were prepared with US retrotip (Group 1), 20 teeth with Er: YAG laser (Group 2), and 10 teeth without retropreparation (control group). The root-end surfaces were examined under a scanning electron microscope (SEM). Then the cracks of the resected root surfaces were evaluated on microphotographs. RESULTS No statistically significant difference was detected between US Group and Laser Group for complete, incomplete, intradentinal, and total number of cracks (P = 0.47, P = 0.80, P = 0.69, P = 0.869, respectively). CONCLUSION Statistical analysis revealed no significant effect of retropreparation technique on the development of apical cracks (P > 0.05).
Collapse
Affiliation(s)
- Seda Aydemir
- Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkiye
| | - Hale Cimilli
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkiye
| | - Afife Binnaz Hazar Yoruç
- Department of Metallurgical and Materials Engineering, Yildiz Technical University, Istanbul, Turkiye
| | - Nevin Kartal
- Department of Restrorative Dentistry, Faculty of Dentistry, Marmara University, Istanbul, Turkiye
| |
Collapse
|
19
|
Rodríguez-Martos R, Torres-Lagares D, Castellanos-Cosano L, Serrera-Figallo MA, Segura-Egea JJ, Gutierrez-Perez JL. Evaluation of apical preparations performed with ultrasonic diamond and stainless steel tips at different intensities using a scanning electron microscope in endodontic surgery. Med Oral Patol Oral Cir Bucal 2012; 17:e988-93. [PMID: 22926471 PMCID: PMC3505721 DOI: 10.4317/medoral.17961] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2011] [Accepted: 03/18/2012] [Indexed: 11/22/2022] Open
Abstract
Objective: The objective of our study is to analyse (with the help of scanning electron microscopes) the quality of the dental root surface and the appearance of dental cracks after performing apical preparations using two diffe-rent types of ultrasonic tips.
Study design: We used 32 single-rooted teeth that underwent a root canal and apical resection. Afterwards, the teeth were divided into 4 groups of 8 teeth each, with preparations of the apical cavities in the following manner: Group 1: stainless steel ultrasonic tip at 33KHz. Group 2: stainless steel ultrasonic tip at 30KHz. Group 3: diamond ultrasonic tip at 30KHz. Group 4: diamond ultrasonic tip at 33 KHz. The quality of the root surface and the presence of cracks were evaluated by one single observer using a scanning electron microscope.
Results: All of the teeth in our study had cracks after the apical preparations. The mean number of cracks per tooth ranged between 6.1±1.9 (group 1) and 3.5±2.4 (group 4), with a significantly higher number found in the groups that used stainless steel tips (P=.03). The types of cracks produced involved: 8 complete cracks (4.5%), 167 incomplete cracks (94.4%), and 2 intradentinal cracks (1.1%), with no significant differences observed between the different frequencies used for each group.
Conclusions: Stainless steel ultrasonic tips provoked a larger number of cracks than diamond tips. The frequency of vibration used did not have any effect on the number of cracks found.
Key words:Apicoectomy, scanning electron microscope, therapeutic ultrasound, endodontic surgery, dentinal crack.
Collapse
|
20
|
Camargo Villela Berbert FL, de Faria-Júnior NB, Tanomaru-Filho M, Guerreiro-Tanomaru JM, Bonetti-Filho I, Leonardo RDT, Marcantonio RAC. An in vitro evaluation of apicoectomies and retropreparations using different methods. ORAL SURGERY, ORAL MEDICINE, ORAL PATHOLOGY, ORAL RADIOLOGY, AND ENDODONTICS 2010; 110:e57-63. [PMID: 20573528 DOI: 10.1016/j.tripleo.2010.03.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2009] [Revised: 03/02/2010] [Accepted: 03/03/2010] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate: 1) the apical root surface, gutta-percha interface, and preparation time of root-end resections made with burs, ultrasound, or laser; and 2) the thickness of surrounding dentin after laser or ultrasonic root-end cavity preparation. STUDY DESIGN 1) Thirty root-filled teeth were resected as follows: Zekrya bur in group I, Chemical Vapor Deposition (CVD) ultrasonic tip (9.5107-8) in group II, and ErCr:YSGG (Waterlase) in group III. The preparation time was recorded. Replicas of the resected root-ends were examined under a scanning electron microscope (SEM). 2) Thirty root-filled teeth were submitted to apicectomies and root-end cavities were prepared by using: CVD (6.1107-6) ultrasonic retrotips (group IV), EMS (DT-060) ultrasonic retrotips (group V), and ErCr:YSGG laser tips (group VI). Replicas of the root apices were examined under a SEM. RESULTS There were no fissures or fractures on root-end surfaces. The bur produced the smoothest surface (P < .05). Group I had the lowest preparation time (P < .05). The best adaptation between the filling and the root canals walls was observed in group III, but it was not significantly different from group II (P < .05). No resected root-ends had cracks after preparation. Group VI showed the least minimum dentin thickness (P < .05). CONCLUSIONS The 3 methods evaluated did not cause any injury to the root-end surface, but they harmed the apical adaptation. Laser tips removed more dentin than ultrasonic retrotips and should be used with care to avoid overpreparation.
Collapse
|
21
|
Batista de Faria-Junior N, Tanomaru-Filho M, Guerreiro-Tanomaru JM, de Toledo Leonardo R, Camargo Villela Berbert FL. Evaluation of Ultrasonic and ErCr:YSGG Laser Retrograde Cavity Preparation. J Endod 2009; 35:741-4. [DOI: 10.1016/j.joen.2009.02.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2008] [Revised: 02/01/2009] [Accepted: 02/17/2009] [Indexed: 10/20/2022]
|
22
|
de Lange J, Putters T, Baas EM, van Ingen JM. Ultrasonic root-end preparation in apical surgery: a prospective randomized study. ACTA ACUST UNITED AC 2007; 104:841-5. [PMID: 17900941 DOI: 10.1016/j.tripleo.2007.06.023] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2007] [Revised: 05/17/2007] [Accepted: 06/27/2007] [Indexed: 11/28/2022]
Abstract
OBJECTIVE The purpose of this study was to evaluate the potential benefit of an ultrasonic device in apical surgery on the outcome of treatment. STUDY DESIGN A randomized prospective design was used in a standardized treatment protocol. Patients were allocated to treatment with an ultrasonic device (P-Max Newtron) or treatment with a bur in an otherwise similar protocol. One year after treatment the results were evaluated by 2 oral and maxillofacial surgeons who were blinded for the therapy. RESULTS Out of a total group of 399 patients who were included in the study, adequate follow-up could be obtained in 290 patients. The overall success rate in the ultrasonic group was 80.5% and in the group treated with a bur 70.9% (P = .056). In molars, the difference in success rate was significant (P = .02). CONCLUSION The use of an ultrasonic device in apical surgery improved the outcome of treatment. In molars this effect was significant.
Collapse
Affiliation(s)
- Jan de Lange
- Department of Oral and Maxillofacial Surgery, Isala Klinieken, Zwolle, The Netherlands.
| | | | | | | |
Collapse
|
23
|
Wallace JA. Effect of Waterlase laser retrograde root-end cavity preparation on the integrity of root apices of extracted teeth as demonstrated by light microscopy. AUST ENDOD J 2006; 32:35-9. [PMID: 16603044 DOI: 10.1111/j.1747-4477.2006.00006.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Most endodontists use ultrasonic instruments for retrograde root-end cavity preparations even though they have been found to produce cracks. In this laboratory study, thirty-six randomly chosen roots had root-end cavity preparations made with the Waterlase laser and only one questionable intra-canal crack was found. It was concluded that the Waterlase laser when used to make endodontic root-end cavity preparations produces either no cracks, or a very low percentage (2.8%) of cracks.
Collapse
Affiliation(s)
- James A Wallace
- School of Dental Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, USA.
| |
Collapse
|
24
|
STROPKO JOHNJ, DOYON GLENE, GUTMANN JAMESL. Root-end management: resection, cavity preparation, and material placement. ACTA ACUST UNITED AC 2005. [DOI: 10.1111/j.1601-1546.2005.00158.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
25
|
|
26
|
Affiliation(s)
- Thomas von Arx
- Department of Oral Surgery and Stomatology, University of Berne, Switzerland.
| |
Collapse
|
27
|
De Bruyne MAA, De Moor RJG. SEM analysis of the integrity of resected root apices of cadaver and extracted teeth after ultrasonic root-end preparation at different intensities. Int Endod J 2005; 38:310-9. [PMID: 15876295 DOI: 10.1111/j.1365-2591.2005.00949.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
AIM To compare the integrity of root apices of cadaver and extracted teeth after resection, ultrasonic root-end cavity preparation at medium and low ultrasonic power settings and retrieval. METHODOLOGY Root canal treatment, perpendicular root-end resection and root-end preparation were performed on single-rooted anterior and premolar teeth (49 teeth in situ in maxillary and mandibular jaws from cadavers and 45 extracted teeth). Apical root-end cavities were prepared with the S12/90 degrees D tip and the Suni-Max ultrasonic unit (Satelec, Merignac, France) at the intensity prescribed by the manufacturer (power 7 at power mode S) (34 cadaver teeth, 30 extracted teeth) and at a lower intensity (power 4 at power mode S) (15 cadaver teeth, 15 extracted teeth). After ultrasonic preparation the cadaver teeth were retrieved from the jaws. Exaflex impressions (GC Corporation, Tokyo, Japan) were made of the root apices after resection, root-end preparation and retrieval. These impressions were processed for SEM analysis, and the recordings evaluated for cracks and marginal chipping. RESULTS In general, extracted teeth showed significantly more cracks and chipping than cadaver teeth. Lowering the ultrasonic power from medium to low intensity resulted in equal scores for cracks on extracted teeth and for chipping on cadaver teeth, in higher scores for cracks on cadavers and in lower scores for chipping on extracted teeth. Complete cracks and cracks originating from the root surface occurred only in extracted teeth. CONCLUSIONS The number of cracks and degree of chipping caused by ultrasonic root-end preparation was higher on extracted teeth than on cadaver teeth. Lowering the ultrasonic power from medium to low intensity cannot be recommended as it resulted in more cracks and equal chipping on cadaver teeth. Investigation of techniques and materials should be conducted in situ and not on extracted teeth.
Collapse
Affiliation(s)
- M A A De Bruyne
- Department of Operative Dentistry and Endodontology, Dental School, Ghent University, Ghent University Hospital, Gent, Belgium.
| | | |
Collapse
|
28
|
Taschieri S, Testori T, Francetti L, Del Fabbro M. Effects of ultrasonic root end preparation on resected root surfaces: SEM evaluation. ACTA ACUST UNITED AC 2004; 98:611-8. [PMID: 15529135 DOI: 10.1016/j.tripleo.2004.04.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The purpose of this study was to investigate the in vitro effect of ultrasonic retrotips on root end surfaces. STUDY DESIGN Root end resection was performed on 45 single-root teeth endodontically treated after extraction. Setting the ultrasonic device at full power, a retrograde cavity was made by a stainless steel tip in 9 specimens (SS-FP). In another 9 samples a diamond tip was used (D-FP). Setting the intensity of the ultrasonic device at half power, 9 specimens were treated using stainless steel tips (SS-HP) and 9 using diamond tip (D-HP). Nine teeth were only apically resected and used as controls. Histologic serial sections were examined by scanning electron microsope to assess the number of root-face cracking, the marginal quality, and the crack type. RESULTS No significant difference between diamond and stainless steel groups was found at a given power setting. Significant differences were found between SS-FP and SS-HP group for both the number of cracks and the marginal quality.
Collapse
Affiliation(s)
- Silvio Taschieri
- Section of Endodontics, Department of Odontology, Galeazzi Institute, University of Milano, Milan, Italy
| | | | | | | |
Collapse
|
29
|
Wright HM, Loushine RJ, Weller RN, Kimbrough WF, Waller J, Pashley DH. Identification of Resected Root-End Dentinal Cracks: A Comparative Study of Transillumination and Dyes. J Endod 2004; 30:712-5. [PMID: 15448465 DOI: 10.1097/01.don.0000125876.26495.20] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The dilemma of diagnosing and possibly treating dentinal cracks continues to present a challenge in endodontics. The purpose of this in vitro study was to compare the effectiveness of transillumination and dyes in identifying root-end dentinal cracks. Fifty maxillary central incisors were decoronated, and the canals were instrumented to an ISO size 50 at the working length. The apical 3 mm of the roots was resected, and cracks were artificially created in the apical dentin. Four independent examiners evaluated the root ends at x8 magnification with a surgical operating microscope using transillumination (group 1), sodium fluorescein dye (group 2), caries detect dye (group 3), methylene blue dye (group 4), and methylene blue plus transillumination (group 5). The examiners' ability to identify root ends correctly with and without cracks was analyzed by comparing the data with the predetermined standard (cracked and noncracked) using logistic regression analysis. All techniques used were shown to be more effective than random chance at diagnosing cracks. The areas under the curve of the different techniques were as follows: transillumination, 0.81 (95% confidence interval [CI], 0.69-0.93); sodium fluorescein, 0.72 (95% CI, 0.58-0.86); caries detector, 0.76 (95% CI, 0.63-0.89); methylene blue, 0.70 (95% CI, 0.55-0.84); and methylene blue plus transillumination, 0.82 (95% CI, 0.70-0.94). Thus, the crack assessment techniques that gave the best discrimination between cracked and noncracked specimens, regardless of rater, was methylene blue plus transillumination. This study emphasizes the usefulness of transillumination along with magnification in detecting dentinal cracks.
Collapse
Affiliation(s)
- Henry M Wright
- Department of Endodontics, School of Dentistry, Medical College of Georgia, Augusta, GA 30912-1244, USA
| | | | | | | | | | | |
Collapse
|
30
|
Esen E, Yoldas O, Kürkçü M, Doğan MC, Seydaoğlu G. Apical Microleakage of Root-End Cavities Prepared by CO2 Laser. J Endod 2004; 30:662-4. [PMID: 15329573 DOI: 10.1097/01.don.0000125316.89703.e2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This in vitro study in extracted human teeth was designed to compare the degree of dye penetration of root-end cavities prepared by CO2 laser, ultrasonic retrotip, or rotary instrument. Eighty-two human anterior teeth were prepared and obturated with laterally condensed gutta-percha and sealer. Root-end resection was performed at 90 degrees, 3 mm from apex. Root-end cavities were prepared by CO2 laser beam, ultrasonic retrotips, or bur and were filled with amalgam. The teeth were isolated and immersed in basic fuchsin at 36 degrees C for 48 hours. The roots were split longitudinally and examined by a stereomicroscope. Leakage was quantified by linear measurement of dye penetration with the aid of image-analyzing software. Apical leakage in the CO2 laser group was significantly less than in the ultrasonic retrotip and bur groups. The difference between the ultrasonic and bur groups was insignificant. Based on the results of this in vitro study, application of CO2 laser for root-end cavity preparation appears to decrease the apical leakage.
Collapse
Affiliation(s)
- Emin Esen
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Cukurova University, Adana, Turkey.
| | | | | | | | | |
Collapse
|
31
|
Gondim E, Zaia AA, Gomes BPFA, Ferraz CCR, Teixeira FB, Souza-Filho FJ. Investigation of the marginal adaptation of root-end filling materials in root-end cavities prepared with ultrasonic tips. Int Endod J 2003; 36:491-9. [PMID: 12823705 DOI: 10.1046/j.1365-2591.2003.00679.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIM To compare the surface topography of root apices following ultrasonic root-end preparation, and again after root-end fillings submitted to three different finishing techniques. METHODOLOGY Eighty-one root-end cavities prepared ultrasonically in human canines, were divided at random into three test groups of 27 each. The cavities were filled with Super-EBA, IRM, or ProRoot-MTA and finished by ball burnishing. Eighteen roots from each group received a final finish with either a 30-fluted tungsten carbide finishing bur, or a Zekrya carbide 28 mm bur after storage in water at 37 degrees C for 24 h. The root-end surface topographies were reproduced by means of polyvinylsiloxane impressions and epoxy resin replicas. Scanning electron micrography (SEM) images of each replica were taken prior to and after root-end filling. An image analysis system was used to compare the alteration of the marginal chipping areas and to calculate the gaps located in the dentine/root-end filling interface. RESULTS When a bur was used to finish the set materials, a significant (P < 0.05) area of marginal chipping was eliminated. The finishing technique did not significantly (P > 0.05) affect the incidence of gaps in groups root-end filled with MTA or IRM. Super-EBA and IRM retrofillings finished with a ball burnisher or a Zekrya bur displayed a significantly (P < 0.05) larger calculated gap area than roots filled with MTA. CONCLUSION Under this in vitro study, the marginal adaptation of MTA was good with or without finishing procedures. Applying a finishing bur over the condensed and set IRM and Super-EBA created better marginal adaptation.
Collapse
Affiliation(s)
- E Gondim
- Endodontic Unit, School of Dentistry of Piracicaba, State University of Campinas - UNICAMP, Piracicaba - SP, Brazil.
| | | | | | | | | | | |
Collapse
|
32
|
Gondim E, Gomes BPFAD, Ferraz CCR, Teixeira FB, Souza-Filho FJD. Effect of sonic and ultrasonic retrograde cavity preparation on the integrity of root apices of freshly extracted human teeth: scanning electron microscopy analysis. J Endod 2002; 28:646-50. [PMID: 12236308 DOI: 10.1097/00004770-200209000-00005] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Sonic and ultrasonic root-end preparation devices permit the preparation of conservative and straight cavities. However, microfractures and marginal chipping can occur due to the vibratory action of such instruments. The purpose of this study was to evaluate the effect of retrograde preparations by using sonic and ultrasonic tips on the integrity of root-end surfaces. Eighty, human anterior teeth were grouped according to size and treated as follows: treatment 1: root-end resection (RR) and root-end cavity preparation (RP) with KIS ultrasonic retrotip; treatment 2: RR and RP with Satelec S12/90 (no diamond coating) ultrasonic retrotip; treatment 3: RR and RP with a diamond-coated retrotip attached to a sonic device (Sonics); treatment 4: RR and RP with Satelec S12/90D (diamond coated) ultrasonic retrotip. The root-end surface topographies were assayed by means of polyvinylsiloxane impressions and epoxy resin replicas. SEM pictures of each sample were taken before and after preparation, and the images were evaluated by using an image processing and analysis system. The parameters evaluated were shape quality, presence of cracks, and marginal chipping. The results showed no statistically significant differences among anatomic groups, treatments, or tooth sizes (p > 0.05). Because treatment 3 removed more dental structure than the others did, its use on small teeth is inadvisable.
Collapse
Affiliation(s)
- Eudes Gondim
- Endodontic Unit, School of Dentistry of Piracicaba, State University of Campinas-UNICAMP-Piracicaba-SP, Brazil
| | | | | | | | | |
Collapse
|
33
|
Navarre SW, Steiman HR. Root-end fracture during retropreparation: a comparison between zirconium nitride-coated and stainless steel microsurgical ultrasonic instruments. J Endod 2002; 28:330-2. [PMID: 12043876 DOI: 10.1097/00004770-200204000-00018] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The purpose of this study was to evaluate a stainless steel (CT-5) and zirconium nitride coated (KiS) microsurgical ultrasonic instrument with regard to possible root-end fracture production during retropreparation. Forty extracted human central incisors were prepared in a crown-down fashion. Canals were obturated with gutta-percha by lateral condensation. Root-ends were resected. Teeth were placed in methylene blue for 48 h and evaluated by three independent evaluators under microscope. Teeth with existing fractures were eliminated from the study. The remaining teeth were randomly divided into two equal groups. Group A was prepared with the CT-5 tip and Group B with the KiS tip. Preparation time was recorded for all roots. The teeth were again immersed in methylene blue for 48 h and reevaluated. No root-end fractures were produced by either the KiS or CT-5 microsurgical ultrasonic instruments.
Collapse
|
34
|
Peters CI, Peters OA, Barbakow F. An in vitro study comparing root-end cavities prepared by diamond-coated and stainless steel ultrasonic retrotips. Int Endod J 2001; 34:142-8. [PMID: 11307263 DOI: 10.1046/j.1365-2591.2001.00367.x] [Citation(s) in RCA: 40] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIM This study compared the appearance of root-end cavity preparations and the time required to prepare them using prototype ultrasonic diamond-coated (DC) and stainless-steel (SS) retrotips. METHODOLOGY In 12 maxillary and 12 mandibular molar teeth 48 root-end cavities were prepared ultrasonically in the palatal, mesio-buccal, distal and mesial root-ends using DC and SS retrotips, alternately. Replicas of the resected root tips and the root-end cavities were examined under a scanning electron microscope (SEM), recording (i) incidence and extent of dentine cracks (ii) minimum remaining thickness of the dentine walls and (iii) surface quality of the resected root-ends. The time taken to complete the preparation was also recorded. Means of these parameters were compared for both types of retrotips using nonparametric tests. RESULTS No resected root-ends had cracks before preparation. However, after preparation one root-end cavity shaped by an SS retrotip had a microcrack visible at 23x magnification. Four and seven other root-ends had crazed surfaces in the DC and SS groups, respectively (P > 0.05). Remaining minimum dentine thickness was 0.56 +/- 0.28 mm and 0.71 +/- 0.24 for the DC and SS groups, respectively, and this difference was significant (P < 0.05). A root-end cavity in one specimen in the DC group was perforated. Preparation times ranged from 25 s to 361 s and were significantly lower for DC tips (P < 0.01) than the SS tips. The time required to prepare root-end cavities also differed between roots; root-end preparation in mandibular molars was more time consuming. CONCLUSIONS A better quality surface was produced by the prototype diamond-coated retrotips, in less time than the SS retrotips, which in turn caused fewer cracks than previously reported. DC retrotips removed more dentine than SS retrotips and should therefore be used with care to avoid overpreparation or perforation.
Collapse
Affiliation(s)
- C I Peters
- Endodontic Division, Department of Preventive Dentistry, Cariology and Periodontology, University of Zurich, Plattenstr. 11, CH-8028 Zurich, Switzerland.
| | | | | |
Collapse
|
35
|
Gray GJ, Hatton JF, Holtzmann DJ, Jenkins DB, Nielsen CJ. Quality of root-end preparations using ultrasonic and rotary instrumentation in cadavers. J Endod 2000; 26:281-3. [PMID: 11199736 DOI: 10.1097/00004770-200005000-00007] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Prior investigations have demonstrated dentinal cracking and chipping during ultrasonic preparation of the root-end. This study compared the frequency of cracking and chipping in two groups, cadaver and extracted teeth, using an indirect resin technique. Preparations were performed using either a 33 1/2 inverted cone bur in a high-speed handpiece, or with ultrasonics using a CT-2 tip at either high or low intensity. After replication of the root-end in epoxy resin, all teeth were evaluated for cracking and chipping under scanning electron microscopy. Statistical analysis using a general contingency table or ANOVA with Scheffé post-hoc analysis (p = 0.05) revealed no significant difference between all groups in terms of root-end cracking. In extracted teeth (n = 15), rotary instrumentation produced less chipping than either ultrasonic technique. Varying the intensity was not significant. There was no significant difference between any instrumentation group in cadaver teeth (n = 10) related to the amount of chipping.
Collapse
Affiliation(s)
- G J Gray
- Department of Applied Dental Medicine, Southern Illinois University School of Dental Medicine, 2800 College Avenue, Alton, IL 62002-4798, USA
| | | | | | | | | |
Collapse
|
36
|
Brent PD, Morgan LA, Marshall JG, Baumgartner JC. Evaluation of diamond-coated ultrasonic instruments for root-end preparation. J Endod 1999; 25:672-5. [PMID: 10687526 DOI: 10.1016/s0099-2399(99)80353-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Ultrasonic instrumentation has been associated with cracking of the dentin in the area of the root-end preparation. The purpose of this study was to evaluate root-end preparations for cracking and to describe cavosurface morphology after the use of diamond-coated instruments. Forty teeth were inspected for intradentin cracks, incomplete canal cracks, and complete canal cracks before and after preparation with a stainless steel CT-5 ultrasonic instrument and again after root-end preparation with an S12D/90 degrees diamond-coated instrument. Six teeth had polyvinylsiloxane impressions taken of the root ends after preparation with the CT-5 and again after preparation with the diamond-coated instrument. Replicas were made, split, sputter-coated, and inspected using the scanning electron microscope. This study indicates that use of the diamond-coated instrument for root-end preparation does not result in significant root-end cracking and that it can remove cracks created by a prior instrument's use. The use of the diamond-coated instrument resulted in a heavily abraded, debris-covered cavosurface that may affect the apical seal.
Collapse
Affiliation(s)
- P D Brent
- Department of Endodontology, Oregon Health Sciences University School of Dentistry, Portland 97201, USA
| | | | | | | |
Collapse
|
37
|
Abstract
The purpose of this in vivo study was to evaluate root-ends for cracks after root resection and again after ultrasonic root-end preparation in patients undergoing endodontic surgery. Endodontic surgery was performed on 25 roots from 20 patients. In vivo vinyl polysiloxane impressions were made after root resection and again after ultrasonic root-end preparations. Epoxy resin casts were made from the impressions and scanning electron micrographic examination of the root-end replicas was performed. There was no evidence of cracks after root resection. One incomplete canal crack was evident after ultrasonic root-end preparation.
Collapse
Affiliation(s)
- L A Morgan
- Oregon Health Sciences University School of Dentistry, Portland, OR
| | | |
Collapse
|
38
|
Kosa DA, Marshall G, Baumgartner JC. An analysis of canal centering using mechanical instrumentation techniques. J Endod 1999; 25:441-5. [PMID: 10530247 DOI: 10.1016/s0099-2399(99)80275-1] [Citation(s) in RCA: 48] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The purpose of this study was to compare canal transportation in moderately curved canals using mechanical instrumentation systems. Mesial roots of mandibular first or second molars were mounted in resin using a modified Bramante muffle system and divided into four groups. The roots were cross-sectioned 2 mm from the working length and at the height of root curvature. Tracings of the canal were made from preinstrumentation slides of the cross-sections. The canals were prepared using ProFile Series 29 rotary instruments, Quantec 2000 rotary instruments, Flex-R files in the Endo Gripper contra-angle handpiece, and Shaping Hedstrom files in the M4 contra-angle handpiece. Tracings of the prepared canals were made onto the originals from postinstrumentation slides. A canal centering ratio was calculated along the line of maximum transportation. Quantec 2000 rotary instruments yielded significantly greater transportation at the apical level when compared with the Profile Series 29 system. There were no other significant differences in transportation at either level. There were no differences in the direction of canal transportation between instrument systems, and the direction of canal transportation was not related to the direction of canal curvature. Canal preparation time was shortest with Profile Series 29 system followed by Flex-R files in the Endo Gripper, Quantec 2000, and Shaping Hedstrom files in the M4.
Collapse
Affiliation(s)
- D A Kosa
- Oregon Health Sciences University, School of Dentistry, Portland 97201, USA
| | | | | |
Collapse
|
39
|
Yatsushiro JD, Baumgartner JC, Tinkle JS. Longitudinal study of the microleakage of two root-end filling materials using a fluid conductive system. J Endod 1998; 24:716-9. [PMID: 9855820 DOI: 10.1016/s0099-2399(98)80160-x] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
A comparison of the microleakage of mineral trioxide aggregate (MTA) and a high copper admix amalgam (Valiant PhD) in root-end preparations was made using a fluid conductive device. Thirty-three bilaterally matched pairs of extracted, single-rooted teeth were prepared and obturated using lateral compaction of gutta-percha. The root-ends were resected and 3-mm-deep class I cavity preparations were made. The root-end preparations were filled with either amalgam or MTA. Guttapercha coronal to the root-end fillings was removed leaving only the amalgam or MTA present as a barrier to fluid movement. In the fluid-conductive device, the root canals were filled with a phosphate-buffered saline solution at a pressure of 10 psi. The flow of fluid was measured and compared at 1, 2, 3, 4, 8, 12, 16, 20, and 24 wk. The results showed amalgam to have significantly higher microleakage after 4 wk and higher variability compared with the MTA group.
Collapse
Affiliation(s)
- J D Yatsushiro
- Department of Endodontology, Oregon Health Sciences University, School of Dentistry, Portland, USA
| | | | | |
Collapse
|
40
|
Calzonetti KJ, Iwanowski T, Komorowski R, Friedman S. Ultrasonic root end cavity preparation assessed by an in situ impression technique. ORAL SURGERY, ORAL MEDICINE, ORAL PATHOLOGY, ORAL RADIOLOGY, AND ENDODONTICS 1998; 85:210-5. [PMID: 9503458 DOI: 10.1016/s1079-2104(98)90428-0] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PROBLEM In vitro studies have demonstrated microfractures in resected roots after root end cavity preparation with ultrasonic tips. Such microfractures are of concern; however, they may be artifacts. OBJECTIVES To assess the incidence of microfractures after ultrasonic root end cavity preparation in situ. STUDY DESIGN Fifty-two roots in two cadavers were endodontically treated, the soft tissues excised, and the root ends exposed and resected. The resected root surfaces were replicated with polyvinylsiloxane impressions. Root end cavities were prepared with ultrasonic tips, then impressed a second time. The roots were retrieved; 25 were processed for direct SEM examination as were both the impressions of each root. The specimens were examined by stereomicroscope and scanning electron microscope. RESULTS In the impressions, the resected and prepared surfaces appeared irregular, but none demonstrated microfractures. In contrast, 15 retrieved roots showed microfractures. CONCLUSIONS Ultrasonic root end cavity preparation in situ did not cause root microfractures, and the impression technique could be clinically usable with minor modifications.
Collapse
Affiliation(s)
- K J Calzonetti
- Department of Endodontics, Faculty of Dentistry, University of Toronto, Ontario, Canada
| | | | | | | |
Collapse
|
41
|
Thompson JY, Bayne SC, Swift EJ, Stamatiades P. Dental materials citations: Part A, January to June 1997. Dent Mater 1997; 13:270-85. [PMID: 11696907 DOI: 10.1016/s0109-5641(97)80039-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE A search was conducted in biomedical journals published from January 1997 to June 1997 to identify all dental materials publications and sort them into major categories. METHODS Tables of contents for 79 journals for the period of January to June, 1997 were inspected and divided into 17 categories. Citations were analyzed by both frequency in journals and in categories, as well as compared to frequencies for previous years. RESULTS A total of 445 citations were detected in 79 journals for the period January 1997 to June 1997. Certain journals (n = 19) demonstrated a higher citation frequency (> or = 10 citations for 6 months) and represented 77.8% of all citations. The greatest number of citations continued to involve bonding (n = 97), resin-based restorative materials (composites; glass ionomers) (n = 95), prosthodontic materials (n = 51), and pulp protection/luting materials (n = 48). Frequencies by category were very similar to those for the last four years. SIGNIFICANCE The compiled literature citations provide a supplement for researchers and academicians seeking information in existing electronic databases.
Collapse
Affiliation(s)
- J Y Thompson
- Department of Operative Dentistry, School of Dentistry, University of North Carolina, Chapel Hill, North Carolina, USA.
| | | | | | | |
Collapse
|