1
|
Cumbo E, Gallina G, Messina P, Bilello G, Isaqali Karobari M, Scardina GA. Soldering in Dentistry: An Updated Technical Review. J Clin Med 2024; 13:809. [PMID: 38337503 PMCID: PMC10856638 DOI: 10.3390/jcm13030809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/29/2023] [Accepted: 01/29/2024] [Indexed: 02/12/2024] Open
Abstract
INTRODUCTION The need to permanently join two or more pieces of metal using heat is a frequent condition in various fields of medicine such as dentistry. Welding, brazing and soldering are permanent joining techniques between different metals that require in-depth background knowledge in order to obtain predictable results. AIM This review examines the different methods of joining metals using heat and their fields of application. DISCUSSION It is possible to create permanent metal joints in various phases of the creation of final products that will be used on the patient. In several cases, welds are also made directly by the manufacturer during industrial processing. In dentistry, dental laboratories perform complex welds mainly on dental prostheses and orthodontic appliances during the production process. It is also possible to obtain intraoral welding carried out by the clinician inside the patient's oral cavity. Welding can be carried out using combustible gases, electric current, infrared light and laser light through different technical procedures which must be chosen according to the specific needs and the metals to be joined. CONCLUSIONS It is useful for the dentist and dental technician to know the different welding methods, including those carried out in the factory by the manufacturer, to better understand the physical properties and mechanical resistance of the components marketed for the construction of prostheses and orthodontic appliances. The enormous variety of conditions in which those who practice welding can find themselves therefore presupposes in-depth knowledge in this field in order to apply the most suitable technique.
Collapse
Affiliation(s)
- Enzo Cumbo
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, 90133 Palermo, Italy; (E.C.); (G.G.); (P.M.); (G.B.)
| | - Giuseppe Gallina
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, 90133 Palermo, Italy; (E.C.); (G.G.); (P.M.); (G.B.)
| | - Pietro Messina
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, 90133 Palermo, Italy; (E.C.); (G.G.); (P.M.); (G.B.)
| | - Giuseppa Bilello
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, 90133 Palermo, Italy; (E.C.); (G.G.); (P.M.); (G.B.)
| | - Mohmed Isaqali Karobari
- Dental Research Unit, Center for Global Health Research, Saveetha Medical College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai 600077, Tamil Nadu, India;
| | - Giuseppe Alessandro Scardina
- Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.), University of Palermo, 90133 Palermo, Italy; (E.C.); (G.G.); (P.M.); (G.B.)
| |
Collapse
|
2
|
Alhajhamoud M, Ozbey S, Ilgaz MA, Candan L, Cinar I, Vukotić M, Čorović S, Miljavec D, Kayahan E. Laser Welding of Ti6Al4V Titanium Alloy in Air and a Water Medium. MATERIALS (BASEL, SWITZERLAND) 2022; 15:9088. [PMID: 36556894 PMCID: PMC9782241 DOI: 10.3390/ma15249088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 12/07/2022] [Accepted: 12/13/2022] [Indexed: 06/17/2023]
Abstract
Ti6Al4V titanium alloys are widely used in a variety of scientific and industrial fields. Laser beam welding is one of the most effective techniques for the joining of titanium plates. The main objective of this study was to investigate the influence of the most important laser parameters on welding performance of titanium alloy in two different physical environments such as air and water (i.e., serum) media. Specifically, the laser beam welding of 2 mm thick Ti6Al4V samples was applied using an Nd:YAG laser in open-air welding using argon as a shielding gas, and in wet welding using a serum environment. The deepest penetration was achieved at -3 mm focal position with 11 J of laser energy in both investigated media (i.e., air and serum). The maximum hardness (1130 HV) was achieved for the focal position of -4 mm in serum medium while it was 795 HV for a focal position of -5 mm in air medium. The minimum (1200 μm and 800 μm) and maximum (1960 μm and 1900 μm) weld widths were observed for air and serum medium, respectively. After the welding process, martensite, massif martensite, and transformed martensite were observed in the microstructure of Ti6Al4V. To the best of our knowledge, the underwater wet welding of titanium alloy was carried out and reported for the first time in this study.
Collapse
Affiliation(s)
- Mohamad Alhajhamoud
- Biomedical Engineering, Natural and Applied Sciences, Kocaeli University, Umuttepe, Kocaeli 41380, Turkey
- Laser Technologies Research and Application Center (LATARUM), Kocaeli University, Yeniköy, Kocaeli 41275, Turkey
| | - Sayit Ozbey
- Laser Technologies Research and Application Center (LATARUM), Kocaeli University, Yeniköy, Kocaeli 41275, Turkey
- Maritime Faculty, Kocaeli University, Marine Eng. Karamürsel, Kocaeli 41500, Turkey
| | - Mehmet Alp Ilgaz
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Levent Candan
- Laser Technologies Research and Application Center (LATARUM), Kocaeli University, Yeniköy, Kocaeli 41275, Turkey
| | - Ibrahim Cinar
- Laser Technologies Research and Application Center (LATARUM), Kocaeli University, Yeniköy, Kocaeli 41275, Turkey
| | - Mario Vukotić
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Selma Čorović
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Damijan Miljavec
- Faculty of Electrical Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
| | - Ersin Kayahan
- Biomedical Engineering, Natural and Applied Sciences, Kocaeli University, Umuttepe, Kocaeli 41380, Turkey
- Laser Technologies Research and Application Center (LATARUM), Kocaeli University, Yeniköy, Kocaeli 41275, Turkey
- Maritime Faculty, Kocaeli University, Marine Eng. Karamürsel, Kocaeli 41500, Turkey
| |
Collapse
|
3
|
Kümbüloğlu Ö, Koyuncu B, Yerlioğlu G, Al-Haj Husain N, Özcan M. Stress Distribution on Various Implant-Retained Bar Overdentures. MATERIALS 2022; 15:ma15093248. [PMID: 35591581 PMCID: PMC9101733 DOI: 10.3390/ma15093248] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/24/2022] [Accepted: 04/27/2022] [Indexed: 02/01/2023]
Abstract
The purpose of this study was to evaluate the effects of various fabrication techniques and materials used in implant-supported mandibular overdentures with a Hader bar attachment over added stress distribution. Three-dimensional geometric solid models, consisting of two implants (3.3 mm × 12 mm) placed at the bone level on both mandibular canine regions and a Hader bar structure, were prepared. Model 1 simulated a bar retentive system made from Titanium Grade 5 material by Computer Numerical Control (CNC) milling technique without using any converting adapter/multi-unit element on the implants, while Model 2 simulated the same configuration, but with converting adapters on the implants. Model 3 simulated a bar retentive system made from Cobalt-Chromium material, made by using conventional casting technique with converting adapters on the implants. Static loads of 100 Newton were applied on test models from horizontal, vertical and oblique directions. ANSYS R15.0 Workbench Software was used to compare Von Mises stress distribution and minimum/maximum principal stress values, and the results were evaluated by using Finite Element Analysis method. As a result, the highest stress distribution values under static loading in three different directions were obtained in Model 1. Stress was observed intensely around the necks of the implants and the surrounding cortical bone areas in all models. In scope of the results obtained, using converting adapters on implants has been considered to decrease transmission of forces onto implants and surrounding bone structures, thus providing a better stress distribution. It has also been observed that the type of material used for bar fabrication has no significant influence on stress values in those models where converting adapters were used.
Collapse
Affiliation(s)
- Övül Kümbüloğlu
- Department of Prosthodontics, Ege University Faculty of Dentistry, Izmir 35040, Turkey; (Ö.K.); (G.Y.)
| | - Beril Koyuncu
- Department of Prosthodontics, Ege University Faculty of Dentistry, Izmir 35040, Turkey; (Ö.K.); (G.Y.)
- Correspondence: ; Tel.: +90-232-311-2877
| | - Gözde Yerlioğlu
- Department of Prosthodontics, Ege University Faculty of Dentistry, Izmir 35040, Turkey; (Ö.K.); (G.Y.)
- Private Practice at RadixDent, Hurriyet Road, Kordonboyu, No:60, Kartal 34860, Turkey
| | - Nadin Al-Haj Husain
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland;
- Division of Dental Biomaterials, Center of Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland;
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center of Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland;
| |
Collapse
|
4
|
Beyabanaki E, Memari Y, Tadayonfard A, Fayaz A. Fabrication of a customized impression metal jig for an implant-supported overdenture with a milled bar. Dent Res J (Isfahan) 2021. [DOI: 10.4103/1735-3327.313118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
5
|
|
6
|
Abstract
High-velocity impact welding is a kind of solid-state welding process that is one of the solutions for the joining of dissimilar materials that avoids intermetallics. Five main methods have been developed to date. These are gas gun welding (GGW), explosive welding (EXW), magnetic pulse welding (MPW), vaporizing foil actuator welding (VFAW), and laser impact welding (LIW). They all share a similar welding mechanism, but they also have different energy sources and different applications. This review mainly focuses on research related to the experimental setups of various welding methods, jet phenomenon, welding interface characteristics, and welding parameters. The introduction states the importance of high-velocity impact welding in the joining of dissimilar materials. The review of experimental setups provides the current situation and limitations of various welding processes. Jet phenomenon, welding interface characteristics, and welding parameters are all related to the welding mechanism. The conclusion and future work are summarized.
Collapse
|
7
|
Perveen A, Molardi C, Fornaini C. Applications of Laser Welding in Dentistry: A State-of-the-Art Review. MICROMACHINES 2018; 9:E209. [PMID: 30424142 PMCID: PMC6187655 DOI: 10.3390/mi9050209] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 04/23/2018] [Accepted: 04/25/2018] [Indexed: 12/13/2022]
Abstract
The dental industry without lasers is inconceivable right now. This captivating technology has outlasted other possible alternative technologies applied in dentistry in the past due to its precision, accuracy, minimal invasive effect as well as faster operating time. Other alternatives such as soldering, resistance (spot) welding, plasma (torch) welding, and single pulse tungsten inert gas welding have their pros and cons; nevertheless, laser welding remains the most suitable option so far for dental application. This paper attempts to give an insight into the laser principle and types of lasers used for dental purposes, types of dental alloys used by the dentist, and effect of laser parameters on prosthesis/implants. It is apparent from the literature review that laser assisted dental welding will continue to grow and will become an unparalleled technology for dental arena.
Collapse
Affiliation(s)
- Asma Perveen
- Mechanical Engineering, Nazarbayev University, Astana 010000, Kazakhstan.
| | - Carlo Molardi
- Electrical & Electronics Engineering, Nazarbayev University, Astana 010000, Kazakhstan; .
| | - Carlo Fornaini
- Department of Engineering and Architecture, University of Parma, Parma, I-43124, Italy.
| |
Collapse
|
8
|
Xu Z, Qiu C, Yang Y, Zhu Q, Jiang X, Zhang Y, Gao W, Su Y. Ultra-compact tunable silicon nanobeam cavity with an energy-efficient graphene micro-heater. OPTICS EXPRESS 2017; 25:19479-19486. [PMID: 29041141 DOI: 10.1364/oe.25.019479] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Accepted: 07/31/2017] [Indexed: 06/07/2023]
Abstract
We propose and experimentally demonstrate an ultra-compact silicon photonic crystal nanobeam (PCN) cavity with an energy-efficient graphene micro-heater. Owing to the PCN cavity with an ultra-small optical mode volume of 0.145 µm3, the light-matter interaction is greatly enhanced and the thermo-optic (TO) tuning efficiency is increased. The TO tuning efficiency is measured to be as high as 1.5 nm/mW, which can be further increased to 3.75 nm/mW based on numerical simulations with an optimized structure. The time constants with a rise time constant of τrise = 1.11 μs and a fall time constant of τfall = 1.47 μs are obtained in the experiment.
Collapse
|
9
|
Shah K, Lee DJ. An alternative approach for the management of fractured implant abutment screws on a mandibular implant-retained overdenture: A clinical report. J Prosthet Dent 2016; 115:402-5. [DOI: 10.1016/j.prosdent.2015.09.027] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2015] [Revised: 09/09/2015] [Accepted: 09/13/2015] [Indexed: 11/24/2022]
|
10
|
Lee JH, Choi SK, Hong MH. The metallurgical characteristics of non-precious alloys using Nd:YAG laser welding. Biomater Res 2015; 19:25. [PMID: 26635967 PMCID: PMC4668671 DOI: 10.1186/s40824-015-0047-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Accepted: 11/04/2015] [Indexed: 11/19/2022] Open
Abstract
Background This study aimed to determine the effect of hardness change according to penetration depth in the laser fusing zone and observed the correlation of the microstructure as an Nd:YAG laser was irradiated to Ni-Cr alloy for dental use by setting the spot diameter size with respect to defocusing distances. In all groups, the hardness depth profiles in the laser fusing zone and heat-affecteded zone (HAZ) had larger values than those of the base metal. In addition, the hardness values in places beyond the fusing zone and the HAZ were measured as being quantitatively lower. Methods The alloys used in this study were Verabond 2 V, Noritake Super, and Bellabond Plus, which are commercially used non-precious dental alloys. The specimens were cut to have a plate shape with a size of 0.5 × 3.0 × 2.5 mm. This was followed by setting the Nd:YAG laser output, pulse duration, and frequency to 60 W, 10 ms, and 5 Hz, respectively. The laser was then irradiated as the spot diameter condition varied between 0.5 mm and 1.4 mm in accordance with defocusing distance from 0.0 mm to 2.0 mm. After the laser irradiation, a cross-section of the fusing zone in the specimens was observed in terms of laser melted depth, hardness depth profile, and the microstructure of each alloy. Results The observation result of the diffusion of the constituent elements and microstructure using field emission scanning electron microscopy, energy dispersive spectroscopy (EDS), and electron probe micro-analyzer showed that the fusing zone revealed a much finer dendritic form than the base metal due to the self-quenching effect after laser melting, while no change in constituent elements was found although some evaporation of the main elements was observed. Conclusions These results suggest that each Mo and Si combined inter-metallic compounds were formed on the interdendritic area. Through this study, the laser fusing zone had better hardenability due to the inter-metallic compound and grain refinement effect.
Collapse
Affiliation(s)
- Jun-Hee Lee
- Department of Advanced Materials Engineering, Dong-A University, Busan, Korea
| | - Seok-Kyu Choi
- Department of Advanced Materials Engineering, Dong-A University, Busan, Korea
| | - Min-Ho Hong
- Department of Bio-medical Research Institute, Kyungpook National University Hospital, Daegu, Korea
| |
Collapse
|
11
|
Lencioni KA, Macedo AP, Silveira Rodrigues RC, Ribeiro RF, Almeida RP. Photoelastic comparison of as-cast and laser-welded implant frameworks. J Prosthet Dent 2015; 114:652-9. [DOI: 10.1016/j.prosdent.2015.06.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Revised: 06/01/2015] [Accepted: 06/04/2015] [Indexed: 11/28/2022]
|
12
|
Castro MG, Araújo CA, Menegaz GL, Silva JPL, Nóbilo MAA, Simamoto Júnior PC. Laser and plasma dental soldering techniques applied to Ti-6Al-4V alloy: Ultimate tensile strength and finite element analysis. J Prosthet Dent 2015; 113:460-6. [DOI: 10.1016/j.prosdent.2014.10.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Revised: 10/21/2014] [Accepted: 10/22/2014] [Indexed: 10/23/2022]
|
13
|
Simamoto Júnior PC, Resende Novais V, Rodrigues Machado A, Soares CJ, Araújo Raposo LH. Effect of joint design and welding type on the flexural strength and weld penetration of Ti-6Al-4V alloy bars. J Prosthet Dent 2015; 113:467-74. [PMID: 25749091 DOI: 10.1016/j.prosdent.2014.10.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2014] [Revised: 10/08/2014] [Accepted: 10/08/2014] [Indexed: 10/23/2022]
|
14
|
Bock JJ, Bailly J, Fuhrmann RA. Effects of different brazing and welding methods on the fracture load of various orthodontic joining configurations. J Orthod 2014; 36:78-84. [PMID: 19487737 DOI: 10.1179/14653120722986] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Affiliation(s)
- Jens J Bock
- Martin Luther University of Halle Wittenberg, Halle, Germany.
| | | | | |
Collapse
|
15
|
Mechanical properties of thin films of laser-welded titanium and their associated welding defects. Lasers Med Sci 2014; 29:1799-805. [PMID: 23636297 DOI: 10.1007/s10103-013-1334-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Accepted: 04/18/2013] [Indexed: 10/26/2022]
Abstract
The aim of this study was to evaluate the mechanical properties of thin films of laser-welded cast titanium using an interference strain/displacement gauge (ISDG) and to analyze factors that affect laser welding. Dog-bone-shaped small specimens of cast titanium were prepared by wire cutting after they were laser-welded. The specimens were divided into three groups according to the gap distance of the laser weld; the control was non-welded titanium. Small specimens without cast defects detected by X-ray screening were measured by a tensile test machine using ISDG, and stress-strain curves were drawn. Finally, the fracture texture was analyzed. The ultimate tensile strengths (UTSs) of specimens with a gap distance of 0.00, 0.25, and 0.50 mm were 492.16 ± 33.19, 488.09 ± 43.18, and 558.45 ± 10.80 MPa, respectively. There were no significant differences in UTS between the test groups and the control group (p > 0.05). However, the plastic deformation and the percent elongation increased as the gap distance increased. Incomplete penetration defects appeared in groups that had small gap distances, which may have affected the properties of the laser-welded titanium. However, the welding material was still pure titanium. These results suggest that an appropriate gap distance should be maintained to improve the application of dental laser welding.
Collapse
|
16
|
Alhashim A, Flinton RJ. Dental Gypsum Verification Jig to Verify Implant Positions: A Clinical Report. J ORAL IMPLANTOL 2014; 40:495-9. [DOI: 10.1563/aaid-joi-d-12-00196] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- Abdulmohsin Alhashim
- Department of Oral Rehabilitation, College of Dental Medicine, Georgia Health Sciences University, Augusta, Ga
| | - Robert J Flinton
- Department of Restorative Dentistry, University of Medicine and Dentistry of New Jersey – New Jersey Dental School, Newark, NJ
| |
Collapse
|
17
|
Atik E, Dursun CK, Akcan CA, El H, Tözüm TF, Ciğer S. The Comparison of Silver and Laser Soldering Techniques on Periodontal Tissues: A Preliminary Study. Turk J Orthod 2014. [DOI: 10.13076/tjo-d-14-00013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Mohunta VV, Stevenson JA, Lee DJ. Replacing worn overdenture abutments of an unknown implant system by using laser welding: a clinical report. J Prosthet Dent 2014; 112:686-8. [PMID: 24836281 DOI: 10.1016/j.prosdent.2014.04.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Revised: 04/08/2014] [Accepted: 04/08/2014] [Indexed: 11/26/2022]
Abstract
This clinical report describes a procedure for replacing worn ball abutments with low-profile resilient abutments by using laser welding when the implant system for a mandibular implant-supported overdenture could not be identified.
Collapse
Affiliation(s)
- Vrinda V Mohunta
- Resident, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
| | - James A Stevenson
- Dental laboratory supervisor, College of Dentistry, The Ohio State University, Columbus, Ohio
| | - Damian J Lee
- Assistant Professor, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.
| |
Collapse
|
19
|
Kim H, Prasad S, Dunford R, Monaco EA. Strength properties of preceramic brazed joints of a gold-palladium alloy with a microwave-assisted oven and gas/oxygen torch technique. J Prosthet Dent 2014; 112:606-12. [PMID: 24656408 DOI: 10.1016/j.prosdent.2014.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM The effect of microwave brazing on the strength properties of dental casting alloys is not yet known. PURPOSE The purpose of this study was to compare the strength properties of preceramic brazed joints obtained by using a microwave oven and a conventional torch flame for a high noble alloy (Au-Pd). MATERIAL AND METHODS A total of 18 tensile bars made of an Au-Pd ceramic alloy were fabricated. Six specimens were cut and joined with a high-fusing preceramic solder in a specially designed microwave oven, and 6 specimens were joined with a conventional natural gas/oxygen torch. The remaining 6 uncut specimens were tested as a control. All the specimens were subjected to testing with a universal testing machine. A 1-way ANOVA was performed for each strength property tested. RESULTS The tensile strength of the uncut group was the highest (745 ±19 MPa), followed by the microwave group (420 ±68 MPa) and the conventional torch group (348 ±103 MPa) (P<.001); however, no significant difference in tensile strength was found between the microwave group and gas torch group. The tensile strength of the microwave group exceeded ANSI/ADA Standard No. 88, Dental Brazing Alloys (a joint standard of the American National Standards Institute and the American Dental Association). CONCLUSIONS The microwave heating preceramic solder method demonstrated the excellent tensile strength of an Au-Pd alloy and may be an alternative way of joining alloys when a torch flame is contraindicated.
Collapse
Affiliation(s)
- Hyeongil Kim
- Associate Professor, Restorative Dentistry, University at Buffalo, State University of New York, Buffalo, NY.
| | - Soni Prasad
- Assistant Professor, General Dental Sciences, Marquette University, Milwaukee, Wis
| | - Robert Dunford
- Statistician, Department of Oral Sciences, University at Buffalo, State University of New York, Buffalo, NY
| | - Edward A Monaco
- Assistant Professor, Restorative Dentistry, University at Buffalo, State University of New York, Buffalo, NY
| |
Collapse
|
20
|
Al Jabbari YS, Koutsoukis T, Barmpagadaki X, El-Danaf EA, Fournelle RA, Zinelis S. Effect of Nd:YAG laser parameters on the penetration depth of a representative Ni-Cr dental casting alloy. Lasers Med Sci 2013; 30:909-14. [PMID: 24326743 DOI: 10.1007/s10103-013-1502-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2013] [Accepted: 11/25/2013] [Indexed: 11/26/2022]
Abstract
The effects of voltage and laser beam (spot) diameter on the penetration depth during laser beam welding in a representative nickel-chromium (Ni-Cr) dental alloy were the subject of this study. The cast alloy specimens were butted against each other and laser welded at their interface using various voltages (160-390 V) and spot diameters (0.2-1.8 mm) and a constant pulse duration of 10 ms. After welding, the laser beam penetration depths in the alloy were measured. The results were plotted and were statistically analyzed with a two-way ANOVA, employing voltage and spot diameter as the discriminating variables and using Holm-Sidak post hoc method (a = 0.05). The maximum penetration depth was 4.7 mm. The penetration depth increased as the spot diameter decreased at a fixed voltage and increased as the voltage increased at a fixed spot diameter. Varying the parameters of voltage and laser spot diameter significantly affected the depth of penetration of the dental cast Ni-Cr alloy. The penetration depth of laser-welded Ni-Cr dental alloys can be accurately adjusted based on the aforementioned results, leading to successfully joined/repaired dental restorations, saving manufacturing time, reducing final cost, and enhancing the longevity of dental prostheses.
Collapse
Affiliation(s)
- Youssef S Al Jabbari
- Dental Biomaterials Research and Development Chair, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh, 11545, Saudi Arabia,
| | | | | | | | | | | |
Collapse
|
21
|
Atoui JA, Felipucci DNB, Pagnano VO, Orsi IA, Nobilo MADA, Bezzon OL. Tensile and Flexural Strength of Commercially Pure Titanium Submitted to Laser and Tungsten Inert Gas Welds. Braz Dent J 2013; 24:630-4. [DOI: 10.1590/0103-6440201302241] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Accepted: 09/02/2013] [Indexed: 11/21/2022] Open
Abstract
This study evaluated the tensile and flexural strength of tungsten inert gas (TIG) welds in specimens made of commercially pure titanium (CP Ti) compared with laser welds. Sixty cylindrical specimens (2 mm diameter x 55 mm thick) were randomly assigned to 3 groups for each test (n=10): no welding (control), TIG welding (10 V, 36 A, 8 s) and Nd:YAG laser welding (380 V, 8 ms). The specimens were radiographed and subjected to tensile and flexural strength tests at a crosshead speed of 1.0 mm/min using a load cell of 500 kgf applied on the welded interface or at the middle point of the non-welded specimens. Tensile strength data were analyzed by ANOVA and Tukey's test, and flexural strength data by the Kruskal-Wallis test (α=0.05). Non-welded specimens presented significantly higher tensile strength (control=605.84±19.83) (p=0.015) and flexural strength (control=1908.75) (p=0.000) than TIG- and laser-welded ones. There were no significant differences (p>0.05) between the welding types for neither the tensile strength test (TIG=514.90±37.76; laser=515.85±62.07) nor the flexural strength test (TIG=1559.66; laser=1621.64). As far as tensile and flexural strengths are concerned, TIG was similar to laser and could be suitable to replace laser welding in implant-supported rehabilitations.
Collapse
|
22
|
Piveta ACG, Ricci WA, Montandon AAB, Nagle MM. Análise metalográfica do titânio puro submetido à soldagem laser Nd: YAG e TIG. REVISTA DE ODONTOLOGIA DA UNESP 2013. [DOI: 10.1590/s1807-25772013000100001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
INTRODUÇÃO: Os métodos de soldagem mais utilizados em Odontologia não podem ser aplicados ao titânio puro e às suas ligas em função da alta reatividade do titânio com elementos atmosféricos; dessa forma, o mesmo não deve ser soldado por processo comum. OBJETIVO: O objetivo deste trabalho foi avaliar a característica metalúrgica do titânio comercialmente puro sem solda e submetido aos processos de soldagem a laser e TIG. MATERIAL E MÉTODO: Foram confeccionados 15 corpos de prova em titânio comercialmente puro, cinco para cada condição, na forma de hastes cilíndricas, obtidas por fundição odontológica, sob atmosfera de gás argônio e vácuo, com calor produzido por um arco voltaico, com a injeção do titânio sob vácuo-pressão. Três grupos foram formados I: soldagem a laser; II: soldagem TIG, e III: sem solda. Os corpos de prova do grupo I e II foram seccionados ao meio e soldados por TIG e por laser, respectivamente; o grupo III foi mantido sem corte e sem solda, como controle. A análise metalográfica foi realizada sob aumentos de 50×, 100× e 200×, em microscópio. RESULTADO: Pelos resultados obtidos nas micrografias, o titânio comercialmente puro apresentou uma morfologia de grãos equiaxiais da fase α, o cordão de solda a laser apresentou estrutura martensítica e, na TIG, microestrutura Widmanstätten. CONCLUSÃO: A microestrutura martensítica é condizente com a alta taxa de resfriamento proveniente do processo de soldagem a laser. As estruturas martensítica e Widmansttäten são mais refinadas quando comparadas à microestrutura do metal base.
Collapse
|
23
|
Nuñez Pantoja JM, Farina AP, Vaz LG, Consani RL, de Arruda Nóbilo MA, Mesquita MF. Fatigue strength: effect of welding type and joint design executed in Ti-6Al-4V structures. Gerodontology 2011; 29:e1005-10. [DOI: 10.1111/j.1741-2358.2011.00598.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
24
|
Takayama Y, Nomoto R, Nakajima H, Ohkubo C. Comparison of joint designs for laser welding of cast metal plates and wrought wires. Odontology 2011; 101:34-42. [PMID: 22080283 DOI: 10.1007/s10266-011-0049-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2011] [Accepted: 10/24/2011] [Indexed: 11/29/2022]
Abstract
The purpose of the present study was to compare joint designs for the laser welding of cast metal plates and wrought wire, and to evaluate the welded area internally using X-ray micro-focus computerized tomography (micro-CT). Cast metal plates (Ti, Co-Cr) and wrought wires (Ti, Co-Cr) were welded using similar metals. The specimens were welded using four joint designs in which the wrought wires and the parent metals were welded directly (two designs) or the wrought wires were welded to the groove of the parent metal from one or both sides (n = 5). The porosity and gap in the welded area were evaluated by micro-CT, and the maximum tensile load of the welded specimens was measured with a universal testing machine. An element analysis was conducted using an electron probe X-ray microanalyzer. The statistical analysis of the results was performed using Bonferroni's multiple comparisons (α = 0.05). The results included that all the specimens fractured at the wrought wire when subjected to tensile testing, although there were specimens that exhibited gaps due to the joint design. The wrought wires were affected by laser irradiation and observed to melt together and onto the filler metal. Both Mo and Sn elements found in the wrought wire were detected in the filler metal of the Ti specimens, and Ni was detected in the filler metal of the Co-Cr specimens. The four joint designs simulating the designs used clinically were confirmed to have adequate joint strength provided by laser welding.
Collapse
Affiliation(s)
- Yasuko Takayama
- Department of Removable Prosthodontics, Tsurumi University School of Dental Medicine, 2-1-3 Tsurumi, Tsurumi-ku, Yokohama, Japan.
| | | | | | | |
Collapse
|
25
|
Watanabe E, Stigall G, Elshahawy W, Watanabe I. Deflection load characteristics of laser-welded orthodontic wires. Angle Orthod 2011; 82:698-702. [PMID: 22044117 DOI: 10.2319/061411-393.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To compare the deflection load characteristics of homogeneous and heterogeneous joints made by laser welding using various types of orthodontic wires. MATERIALS AND METHODS Four kinds of straight orthodontic rectangular wires (0.017 inch × 0.025 inch) were used: stainless-steel (SS), cobalt-chromium-nickel (Co-Cr-Ni), beta-titanium alloy (β-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (12 mm long each) were made by Nd:YAG laser welding. Two types of welding methods were used: two-point welding and four-point welding. Nonwelded wires were also used as a control. Deflection load (N) was measured by conducting the three-point bending test. The data (n = 5) were statistically analyzed using analysis of variance/Tukey test (P < .05). RESULTS The deflection loads for control wires measured were as follows: SS: 21.7 ± 0.8 N; Co-Cr-Ni: 20.0 ± 0.3 N; β-Ti: 13.9 ± 1.3 N; and Ni-Ti: 6.6 ± 0.4 N. All of the homogeneously welded specimens showed lower deflection loads compared to corresponding control wires and exhibited higher deflection loads compared to heterogeneously welded combinations. For homogeneous combinations, Co-Cr-Ni/Co-Cr-Ni showed a significantly (P < .05) higher deflection load than those of the remaining homogeneously welded groups. In heterogeneous combinations, SS/Co-Cr-Ni and β-Ti/Ni-Ti showed higher deflection loads than those of the remaining heterogeneously welded combinations (significantly higher for SS/Co-Cr-Ni). Significance (P < .01) was shown for the interaction between the two factors (materials combination and welding method). However, no significant difference in deflection load was found between four-point and two-point welding in each homogeneous or heterogeneous combination. CONCLUSION Heterogeneously laser-welded SS/Co-Cr-Ni and β-Ti/Ni-Ti wires provide a deflection load that is comparable to that of homogeneously welded orthodontic wires.
Collapse
Affiliation(s)
- Etsuko Watanabe
- Department of Dental and Biomedical Materials Science, Nagasaki University Graduate School of Biomedical Science, Nagasaki, Japan.
| | | | | | | |
Collapse
|
26
|
Augusta Orsi I, Raimundo LB, Luiz Bezzon O, Antonio de Arruda Nóbilo M, Kuri SE, Rovere CAD, Oliveira Pagnano V. Evaluation of Anodic Behavior of Commercially Pure Titanium in Tungsten Inert Gas and Laser Welds. J Prosthodont 2011; 20:628-31. [DOI: 10.1111/j.1532-849x.2011.00771.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
27
|
Kikuchi H, Kurotani T, Kaketani M, Hiraguchi H, Hirose H, Yoneyama T. Effect of laser irradiation conditions on the laser welding strength of cobalt-chromium and gold alloys. J Oral Sci 2011; 53:301-5. [PMID: 21959656 DOI: 10.2334/josnusd.53.301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Using tensile tests, this study investigated differences in the welding strength of casts of cobalt-chromium and gold alloys resulting from changes in the voltage and pulse duration in order to clarify the optimum conditions of laser irradiation for achieving favorable welding strength. Laser irradiation was performed at voltages of 150 V and 170 V with pulse durations of 4, 8, and 12 ms. For cobalt-chromium and gold alloys, it was found that a good welding strength could be achieved using a voltage of 170 V, a pulse duration of 8 ms, and a spot diameter of 0.5 mm. However, when the power density was set higher than this, defects tended to occur, suggesting the need for care when establishing welding conditions.
Collapse
Affiliation(s)
- Hisaji Kikuchi
- Department of Dental Materials, Nihon University School of Dentistry, Tokyo, Japan.
| | | | | | | | | | | |
Collapse
|
28
|
Nuñez-Pantoja JMC, Takahashi JMFK, Nóbilo MADA, Consani RLX, Mesquita MF. Radiographic inspection of porosity in Ti-6Al-4V laser-welded joints. Braz Oral Res 2011; 25:103-8. [DOI: 10.1590/s1806-83242011005000005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2010] [Accepted: 12/06/2010] [Indexed: 11/21/2022] Open
|
29
|
NUÑEZ-PANTOJA JMC, VAZ LG, NÓBILO MAA, HENRIQUES GEP, MESQUITA MF. Effects of laser-weld joint opening size on fatigue strength of Ti-6Al-4V structures with several diameters. J Oral Rehabil 2011; 38:196-201. [DOI: 10.1111/j.1365-2842.2010.02140.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
30
|
Hjalmarsson L, Örtorp A, Smedberg JI, Jemt T. Precision of Fit to Implants: A Comparison of Cresco™ and Procera® Implant Bridge Frameworks. Clin Implant Dent Relat Res 2010; 12:271-80. [DOI: 10.1111/j.1708-8208.2009.00171.x] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
31
|
Nomoto R, Takayama Y, Tsuchida F, Nakajima H. Non-destructive three-dimensional evaluation of pores at different welded joints and their effects on joints strength. Dent Mater 2010; 26:e246-52. [PMID: 20828805 DOI: 10.1016/j.dental.2010.08.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2009] [Revised: 03/12/2010] [Accepted: 08/09/2010] [Indexed: 10/19/2022]
Abstract
OBJECTIVES The purpose of this study was to measure the porosity in different laser welded cast alloys non-destructively using X-ray micro-focus computerized tomography (micro-CT) and to evaluate the effect of porosity on the tensile strength of the welded joints. MATERIALS AND METHODS The welding procedure was conducted in rectangular cast metals, CoCr, Ti and platinum added gold alloy (AuPt). The metal plates were butted CoCr to CoCr (CoCr/CoCr) or Ti to Ti (Ti/Ti) for welding of similar metals and Ti to AuPt (Ti/AuPt) for welding of dissimilar metals. Specimens were welded under several laser-welding conditions; with groove (normal), without groove (no groove), spatter, crack, or no overlapped welding (no overlap) (n=5). Porosity in the welded area was evaluated using a micro-CT. Tensile strength of the welded specimens was measured at a crosshead speed of 1mm/min. Multiple comparisons of the group means were performed using ANOVA and Fisher's multiple comparisons test (α=.05). The relationship between the porosity and the tensile strength was investigated with a regression analysis. RESULTS Three-dimensional images of Ti/AuPt could not be obtained due to metal artifacts and the tensile specimens of Ti/AuPt were debonded prior to the tensile test. All other welded specimens had porosity in the welded area and the porosities ranged from 0.01% to 0.17%. The fractures of most of the CoCr/CoCr and Ti/Ti specimens occurred in the parent metals. Joint strength had no relationship with the porosity in the welded area (R(2)=0.148 for CoCr/CoCr, R(2)=0.088 for Ti/Ti, respectively). SIGNIFICANCE The small amount of porosity caused by the laser-welding procedures did not affect the joint strength. The joint strength of Ti/AuPt was too weak to be used clinically.
Collapse
Affiliation(s)
- Rie Nomoto
- Department of Dental Engineering, Tsurumi University School of Dental Medicine, 2-1-3 Tsurumi, Tsurumi-ku, Yokohama 230-8501, Japan.
| | | | | | | |
Collapse
|
32
|
Fornaini C, Passaretti F, Villa E, Rocca JP, Merigo E, Vescovi P, Meleti M, Manfredi M, Nammour S. Intraoral laser welding: ultrastructural and mechanical analysis to compare laboratory laser and dental laser. Lasers Med Sci 2010; 26:415-20. [PMID: 20437262 DOI: 10.1007/s10103-010-0788-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2009] [Indexed: 10/19/2022]
Abstract
The Nd:YAG laser has been used since 1970 in dental laboratories to weld metals on dental prostheses. Recently in several clinical cases, we have suggested that the Nd:YAG laser device commonly utilized in the dental office could be used to repair broken fixed, removable and orthodontic prostheses and to weld metals directly in the mouth. The aim of this work was to evaluate, using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and dynamic mechanical analysis (DMA), the quality of the weld and its mechanical strength, comparing a device normally used in dental laboratory and a device normally used in the dental office for oral surgery, the same as that described for intraoral welding. Metal plates of a Co-Cr-Mo dental alloy and steel orthodontic wires were subjected to four welding procedures: welding without filler metal using the laboratory laser, welding with filler metal using the laboratory laser, welding without filler metal using the office laser, and welding with filler metal using the office laser. The welded materials were then analysed by SEM, EDS and DMA. SEM analysis did not show significant differences between the samples although the plates welded using the office laser without filler metal showed a greater number of fissures than the other samples. EDS microanalysis of the welding zone showed a homogeneous composition of the metals. Mechanical tests showed similar elastic behaviours of the samples, with minimal differences between the samples welded with the two devices. No wire broke even under the maximum force applied by the analyser. This study seems to demonstrate that the welds produced using the office Nd:YAG laser device and the laboratory Nd:YAG laser device, as analysed by SEM, EDS and DMA, showed minimal and nonsignificant differences, although these findings need to be confirmed using a greater number of samples.
Collapse
Affiliation(s)
- Carlo Fornaini
- Oral Medicine and Laser-Assisted Surgery Unit, Dental School, Faculty of Medicine, University of Parma, Parma, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Prasad S, Monaco EA. Repairing an implant titanium milled framework using laser welding technology: a clinical report. J Prosthet Dent 2009; 101:221-5. [PMID: 19328274 DOI: 10.1016/s0022-3913(09)00037-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
The application of laser welding technology allows titanium to be welded predictably and precisely to achieve accurate fit of a milled framework. Laser energy results in localized heat production, thereby reducing thermal expansion. Unlike soldering, laser energy can be directed to a small area, making it possible to laser weld close to acrylic resin or ceramic. This article describes the use of laser welding to repair an implant titanium milled fixed denture. A quick, cost-effective, accurate repair was accomplished, and the repaired framework possessed adequate strength and the same precise fit as the original framework.
Collapse
Affiliation(s)
- Soni Prasad
- Postgraduate Prosthodontics, School of Dental Medicine, State University of New York at Buffalo, Buffalo, NY 14214, USA.
| | | |
Collapse
|
34
|
Bock JJ, Bailly J, Gernhardt CR, Fuhrmann RAW. Fracture strength of different soldered and welded orthodontic joining configurations with and without filling material. J Appl Oral Sci 2009; 16:328-35. [PMID: 19089229 PMCID: PMC4327598 DOI: 10.1590/s1678-77572008000500005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2008] [Accepted: 04/18/2008] [Indexed: 11/22/2022] Open
Abstract
The aim of this study was to compare the mechanical strength of different joints made by conventional brazing, TIG and laser welding with and without filling material. Five standardized joining configurations of orthodontic wire in spring hard quality were used: round, cross, 3 mm length, 9 mm length and 7 mm to orthodontic band. The joints were made by five different methods: brazing, tungsten inert gas (TIG) and laser welding with and without filling material. For the original orthodontic wire and for each kind of joint configuration or connecting method 10 specimens were carefully produced, totalizing 240. The fracture strengths were measured with a universal testing machine (Zwick 005). Data were analyzed by ANOVA (p=0.05) and Bonferroni post hoc test (p=0.05). In all cases, brazing joints were ruptured on a low level of fracture strength (186-407 N). Significant differences between brazing and TIG or laser welding (p<0.05, Bonferroni post hoc test) were found in each joint configuration. The highest fracture strength means were observed for laser welding with filling material and 3 mm joint length (998 N). Using filling materials, there was a clear tendency to higher mean values of fracture strength in TIG and laser welding. However, statistically significant differences were found only in the 9-mm long joints (p<0.05, Bonferroni post hoc test). In conclusion, the fracture strength of welded joints was positively influenced by the additional use of filling material. TIG welding was comparable to laser welding except for the impossibility of joining orthodontic wire with orthodontic band.
Collapse
Affiliation(s)
- Jens Johannes Bock
- Department of Orthodontics, Martin-Luther-University Halle, Wittenberg, Germany
| | | | | | | |
Collapse
|
35
|
de Aguiar FA, Tiossi R, Rodrigues RCS, Mattos MDGC, Ribeiro RF. An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis. J Prosthodont 2009; 18:230-4. [PMID: 19141050 DOI: 10.1111/j.1532-849x.2008.00405.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
PURPOSE The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. MATERIALS AND METHODS Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N.cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer's test (p < 0.05). RESULTS When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mum) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 microm) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 microm). On the tightened side, no significant differences were found between the groups (p > 0.05). CONCLUSIONS Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.
Collapse
Affiliation(s)
- Fábio Afrânio de Aguiar
- University of São Paulo, Dental School of Ribeirão Preto, Department of Dental Materials and Prosthodontics, Sao Paulo, Brazil
| | | | | | | | | |
Collapse
|
36
|
Watanabe I, Wallace C. Bond strength of gold alloys laser welded to cobalt-chromium alloy. Open Dent J 2008; 2:109-13. [PMID: 19088892 PMCID: PMC2596600 DOI: 10.2174/1874210600802010109] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2008] [Revised: 07/14/2008] [Accepted: 09/01/2008] [Indexed: 11/22/2022] Open
Abstract
The objective of this study was to investigate the joint properties between cast gold alloys and Co-Cr alloy laser-welded by Nd:YAG laser. Cast plates were fabricated from three types of gold alloys (Type IV, Type II and low-gold) and a Co-Cr alloy. Each gold alloy was laser-welded to Co-Cr using a dental laser-welding machine. Homogeneously-welded and non-welded control specimens were also prepared. Tensile testing was conducted and data were statistically analyzed using ANOVA. The homogeneously-welded groups showed inferior fracture load compared to corresponding control groups, except for Co-Cr. In the specimens welded heterogeneously to Co-Cr, Type IV was the greatest, followed by low-gold and Type II. There was no statistical difference (P<0.05) in fracture load between Type II control and that welded to Co-Cr. Higher elongations were obtained for Type II in all conditions, whereas the lowest elongation occurred for low-gold welded to Co-Cr. This study indicated that, of the three gold alloys tested, the Type IV gold alloy was the most suitable alloy for laser-welding to Co-Cr.
Collapse
Affiliation(s)
- Ikuya Watanabe
- Department of Biomaterials Science, Baylor College of Dentistry, Texas A&M Health Science Center, Dallas, TX, 75246 USA
| | | |
Collapse
|
37
|
Bock JJ, Fraenzel W, Bailly J, Gernhardt CR, Fuhrmann RAW. Influence of different brazing and welding methods on tensile strength and microhardness of orthodontic stainless steel wire. Eur J Orthod 2008; 30:396-400. [PMID: 18617503 DOI: 10.1093/ejo/cjn022] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Jens Johannes Bock
- Department of Orthodontics, University School of Dental Medicine, Martin-Luther-University Halle-Wittenberg, Halle/Saale, Germany.
| | | | | | | | | |
Collapse
|
38
|
Srimaneepong V, Yoneyama T, Kobayashi E, Doi H, Hanawa T. Comparative study on torsional strength, ductility and fracture characteristics of laser-welded α+β Ti–6Al–7Nb alloy, CP Titanium and Co–Cr alloy dental castings. Dent Mater 2008; 24:839-45. [DOI: 10.1016/j.dental.2007.10.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2007] [Revised: 09/24/2007] [Accepted: 10/09/2007] [Indexed: 11/17/2022]
|
39
|
Iijima M, Brantley WA, Yuasa T, Kawashima I, Mizoguchi I. Joining characteristics of β-titanium wires with electrical resistance welding. J Biomed Mater Res B Appl Biomater 2008; 85:378-84. [DOI: 10.1002/jbm.b.30956] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
40
|
Lin MC, Lin SC, Wang YT, Hu SW, Lee TH, Chen LK, Huang HH. Fracture resistance of Nd:YAG laser-welded cast titanium joints with various clinical thicknesses and welding pulse energies. Dent Mater J 2007; 26:367-72. [PMID: 17694746 DOI: 10.4012/dmj.26.367] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to evaluate the fracture resistance of Nd:YAG laser-welded cast titanium (Ti) joints with various clinical thicknesses and welding pulse energies. A four-point bending test was used to assess the effects of various specimen thicknesses (1-3 mm) and welding pulse energies (11-24 J) on the fracture resistance of Nd:YAG laser-welded Ti dental joints. Fracture resistance was evaluated in terms of the ratio of the number of fractured specimens to the number of tested specimens. As for the fracture frequencies, they were compared using the Cochran-Mantel-Haenszel test. Morphology of the fractured Ti joints was observed using a scanning electron microscope. Results showed that decreasing the specimen thickness and/or increasing the welding pulse energy, i.e., increasing the welded area percentage, resulted in an increase in the fracture resistance of the Ti joint. Where fracture occurred, the fracture site would be at the center of the weld metal.
Collapse
Affiliation(s)
- Mau-Chin Lin
- Department of Dental Laboratory Technology, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
| | | | | | | | | | | | | |
Collapse
|
41
|
Iijima M, Brantley WA, Baba N, Alapati SB, Yuasa T, Ohno H, Mizoguchi I. Micro-XRD study of beta–titanium wires and infrared soldered joints. Dent Mater 2007; 23:1051-6. [PMID: 17178150 DOI: 10.1016/j.dental.2006.06.054] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2005] [Revised: 04/17/2006] [Accepted: 06/22/2006] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The purpose of this study was to investigate the metallurgical phases in beta-titanium soldered joints prepared by infrared soldering, using the Micro X-ray diffraction technique (Micro-XRD), and to characterize the Vickers hardness in the soldered beta-titanium wires. METHODS Beta-titanium wires with cross-section dimensions of 0.032in.x0.032in. (TMA, Ormco), and both titanium-based solder (Ti-30Ni-20Cu, Selec) and silver-based solder (Ag-22Cu-17Zn-5Sn, Tomy) were selected. Soldering was performed using infrared radiation (RS-1, Morita) under argon atmosphere. Micro-XRD analyses were performed at room temperature. Micro-XRD spectra were obtained for the boundary region of the soldered beta-titanium wires using 50microm and 10microm diameter analysis regions. Hardness was measured at 30microm intervals from boundary of the diffusion layer and beta-titanium wire. The Kruskal-Wallis test with the Bonferroni and Wilcoxson Mann-Whitney tests for nonparametric means were employed as statistical methods (P<0.05). RESULTS For both types of soldered beta-titanium samples, the Micro-XRD spectra contained four major peaks for body-centered cubic (bcc) beta-titanium. Additional peaks at about 41 and 45 degrees are attributed to Cu-Ti intermetallic phase(s), which may be metastable under soldering conditions. The diffusion layer had greater hardness than bulk beta-titanium for both types of soldered specimens (P<0.05). SIGNIFICANCE Soldering of beta-titanium orthodontic wire by infrared radiation may be acceptable for clinical use, since Micro-XRD spectra revealed that both types of soldered specimens largely retained the bcc beta-titanium structure. Further research is needed to investigate the mechanical properties and corrosion behavior of infrared-soldered beta-titanium wire.
Collapse
Affiliation(s)
- Masahiro Iijima
- Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido, 1757 Kanazawa, Ishikari-Tobetsu, Hokkaido 061-0293, Japan.
| | | | | | | | | | | | | |
Collapse
|
42
|
Watanabe I, Chang J, Chiu Y. Dimensional change of laser-welded gold alloy induced by heat treatment. J Prosthodont 2007; 16:365-9. [PMID: 17559532 DOI: 10.1111/j.1532-849x.2007.00210.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
PURPOSE This study examined the effects of laser welding and heat treatment on the dimensional change of cast gold alloy frameworks. MATERIALS AND METHODS Pairs of cast gold alloy plates were matched, fixed in a jig, and welded in a laser-welding machine at constant welding parameters. The specimens were welded unilaterally (on one surface) or bilaterally (on two surfaces) with five spots as follows: two ends fixed/unilaterally welded (A); two ends fixed/bilaterally welded (AA); one end fixed/unilaterally welded (B); two ends fixed/welded on one surface and then one end fixed/welded on the opposite surface (AB); or one end fixed/bilaterally welded (BB). The dimensional change was determined by measuring the gap between the jig base and one end of the specimen after each welding application. Dimensional change was also measured after two different heat treatments (softening and hardening). The results were analyzed using a two-way ANOVA and Duncan's test (p < 0.05). RESULTS The dimensional change of the specimens fixed at only one end on either surface (AB, B, and BB) was higher compared with the two ends-fixed specimens (A and AA) after laser welding. The heat treatments also increased the dimensional change in all groups except for the B group. The dimensional change was similar for each fixing method between the two types of heat treatment. CONCLUSIONS The method of fixing the specimens in the jig significantly affected the amount of dimensional change of the gold alloys. The heat treatments of the laser-welded specimens increased the dimensional change by releasing the residual stress.
Collapse
Affiliation(s)
- Ikuya Watanabe
- Department of Biomaterials Science, Baylor College of Dentistry, Texas A&M University System Health Science Center, Dallas, TX 75246, USA.
| | | | | |
Collapse
|
43
|
Watanabe I, Baba N, Chang J, Chiu Y. Nd:YAG laser penetration into cast titanium and gold alloy with different surface preparations. J Oral Rehabil 2007; 33:443-6. [PMID: 16671991 DOI: 10.1111/j.1365-2842.2006.01512.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
This study investigated the effect of surface preparation on the Nd:YAG laser penetration into cast titanium and gold alloy. Cast blocks of each metal were given four different surface preparations: (i) coloured with black marker; (ii) air-abraded with 50 microm Al2O3; (iii) ground with SiC points and (iv) polished with 1 microm Al2O3 (mirror-polished). Two blocks with each of the surface preparations were abutted and laser-welded at their interface using the voltages of 210-260 V in increments of 10 V. After the welded blocks were mechanically separated, the laser penetration was measured using computer graphics. Regardless of the surface preparation, an increase in voltage increased the laser penetration for both metals. The laser penetration into titanium prepared with black marker and air-abrasion was significantly deeper than into the titanium ground with SiC points and mirror-polished. Although there were no statistical differences in penetration among the surface preparations for the gold alloy, the penetration in the mirror-polished specimens was shallower than any of the other preparation methods at higher voltages of 240-260 V. The results obtained in this study suggested that broken metal frameworks with finished surfaces should be painted with black marker or air-abraded before laser welding.
Collapse
Affiliation(s)
- I Watanabe
- Department of Biomaterials Science, Baylor College of Dentistry, Texas A & M University System Health Science Center, Dallas, TX 75246, USA.
| | | | | | | |
Collapse
|
44
|
Iijima M, Brantley WA, Yuasa T, Muguruma T, Kawashima I, Mizoguchi I. Joining characteristics of orthodontic wires with laser welding. J Biomed Mater Res B Appl Biomater 2007; 84:147-53. [PMID: 17514661 DOI: 10.1002/jbm.b.30856] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Laser welding 0.016 x 0.022 in. beta-Ti, Ni-Ti, and Co-Cr-Ni orthodontic wires was investigated by measuring joint tensile strength, measuring laser penetration depth, determining metallurgical phases using micro X-ray diffraction (micro-XRD), and examining microstructures with an scanning electron microscope (SEM). Welding was performed from 150 to 230 V. Mean tensile strength for Ni-Ti groups was significantly lower (p < 0.05) than for most other groups of laser-welded specimens. Although mean tensile strength for beta-Ti and Co-Cr-Ni was significantly lower than for control specimens joined by silver soldering, it was sufficient for clinical use. The beta-Ti orthodontic wire showed deeper penetration depth from laser welding than the Ni-Ti and Co-Cr-Ni orthodontic wires. Micro-XRD patterns of laser-welded beta-Ti and Ni-Ti obtained 2 mm from the boundary were similar to as-received specimens, indicating that original microstructures were maintained. When output voltages of 190 V and higher were used, most peaks from joint areas disappeared or were much weaker, perhaps because of a directional solidification effect, evidenced by SEM observation of fine striations in welded beta-Ti. Laser welding beta-Ti and Co-Cr-Ni wires may be acceptable clinically, since joints had sufficient strength and metallurgical phases in the original wires were not greatly altered.
Collapse
Affiliation(s)
- Masahiro Iijima
- Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido, Ishikari-Tobetsu, Hokkaido, Japan.
| | | | | | | | | | | |
Collapse
|
45
|
Zupancic R, Legat A, Funduk N. Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints. J Prosthet Dent 2006; 96:273-82. [PMID: 17052472 DOI: 10.1016/j.prosdent.2006.08.006] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
STATEMENT OF PROBLEM The longevity of prosthodontic restorations is often limited due to the mechanical or corrosive failure occurring at the sites where segments of a metal framework are joined together. PURPOSE The purpose of this study was to determine which joining method offers the best properties to cobalt-chromium alloy frameworks. Brazed and 2 types of laser-welded joints were compared for their mechanical and corrosion characteristics. MATERIAL AND METHODS Sixty-eight cylindrical cobalt-chromium dental alloy specimens, 35 mm long and 2 mm in diameter, were cast. Sixteen specimens were selected for electrochemical measurements in an artificial saliva solution and divided into 4 groups (n=4). In the intact group, the specimens were left as cast. The specimens of the remaining 3 groups were sectioned at the center, perpendicular to the long-axis, and were subsequently rejoined by brazing (brazing group) or laser welding using an X- or I-shaped joint design (X laser and I laser groups, respectively). Another 16 specimens were selected for electrochemical measurements in a more acidic artificial saliva solution. These specimens were also divided into 4 groups (n=4) as described above. Electrochemical impedance spectroscopy and potentiodynamic polarization were used to assess corrosion potentials, breakdown potentials, corrosion current densities, total impedances at lowest frequency, and polarization charge-transfer resistances. The remaining 36 specimens were used for tensile testing. They were divided into 3 groups in which specimen pairs (n=6) were joined by brazing or laser welding to form 70-mm-long cylindrical rods. The tensile strength (MPa) was measured using a universal testing machine. Differences between groups were analyzed using 1-way analysis of variance (alpha=.05). The fracture surfaces and corrosion defects were examined with a scanning electron microscope. RESULTS The average tensile strength of brazed joints was 792 MPa and was significantly greater (P<.05) than the tensile strength of both types of laser-welded joints (404 MPa and 405 MPa). When laser welding was used, successful joining was limited to the peripheral aspects of the weld. The welding technique did not significantly affect the joint tensile strength. Electrochemical measurements indicated that the corrosion resistance of the laser-welded joints was better than of the brazed ones, primarily due to differences in passivation ability. CONCLUSION Laser welding provides excellent corrosion resistance to cobalt-chromium alloy joints, but strength is limited due to the shallow weld penetration. Brazed joints are less resistant to corrosion but have higher tensile strength than laser welds.
Collapse
Affiliation(s)
- Rok Zupancic
- Department of Prosthodontics, University of Ljubljana, Faculty of Medicine, Division of Dental Medicine, Slovenia.
| | | | | |
Collapse
|
46
|
Iijima M, Brantley WA, Kawashima I, Baba N, Alapati SB, Yuasa T, Ohno H, Mizoguchi I. Microstructures of beta-titanium orthodontic wires joined by infrared brazing. J Biomed Mater Res B Appl Biomater 2006; 79:137-41. [PMID: 16615071 DOI: 10.1002/jbm.b.30523] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The microstructures and interdiffusion in brazed beta-titanium orthodontic wires were investigated by scanning electron microscopy and electron probe microanalysis, respectively. Beta-titanium wire (Ti-11Mo-6Zr-4Sn) with cross-section dimensions of 0.032 in. x 0.032 in., titanium-based braze alloy (Ti-30Ni-20Cu), and silver-based braze alloy (Ag-22Cu-17Zn-5Sn) were selected for the study. Brazing was performed using infrared radiation (RS-1) under an argon atmosphere. Specimens were etched with two solutions (2.5% HF + 2.5% HNO(3) + 95% H(2)O; 25% HN(4)OH + 30% H(2)O(2) + 45%H(2)O). It was found that the silver-based braze alloy has a eutectic structure. In the diffusion layer between the beta-titanium wire and this silver-based braze alloy, Cu and Ti were enriched on the wire side, and Sn and Ti were enriched on the braze alloy side. The titanium-based braze alloy has a dendritic structure. Beta-titanium wire specimens brazed with the titanium-based braze alloy had a thicker intermediate area compared to the silver alloy; Ti in the diffusion layer had an irregular concentration gradient, and the braze alloy side had higher Ti concentration. The original microstructure of the beta-titanium wire was not altered with the use of either braze alloy. Infrared brazing of beta-titanium orthodontic wire is acceptable for clinical use, since the wire microstructure did not deteriorate with either the titanium-based or silver-based braze alloy. The differing microstructures of the joint regions for the two braze alloys suggest that the joint strengths may also differ.
Collapse
Affiliation(s)
- Masahiro Iijima
- Department of Orthodontics, School of Dentistry, Health Sciences University of Hokkaido, Ishikari-Tobetsu, Hokkaido, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
47
|
Hart CN, Wilson PR. Evaluation of welded titanium joints used with cantilevered implant-supported prostheses. J Prosthet Dent 2006; 96:25-32. [PMID: 16872927 DOI: 10.1016/j.prosdent.2006.05.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
STATEMENT OF PROBLEM Early failure of laser-welded titanium implant frameworks in clinical practice has prompted an investigation of the strength and durability of welded cantilevered titanium sections. PURPOSE The purpose of this study was to determine the effect that the use of filler wire in laser welding of titanium cantilever frameworks had on the flexural strength and fatigue resistance of the welded joints. MATERIAL AND METHODS Sixty titanium implant-supported frameworks with 12-mm cantilevers were fabricated in 4 groups (n=15), using 3 different laser welding protocols with 0, 1, and 2 weld passes with filler wire, and 1 conventional tungsten inert gas welding method. The volume of filler wire used (mean volumes 0, 1.7, 3.4, and 8.3 mm(3)) was determined by measurement of the length of wire before and after welding each joint. Ten frameworks from each group were tested for ultimate flexural strength by loading the cantilevers 10 mm from the abutment. The remaining 5 frameworks from each group were similarly tested under a simulated masticatory load of 200 N until failure, or to 1 million cycles. A 2-way analysis of variance was used to examine the flexural strengths, and log-rank statistics were applied to cyclic test data (alpha=.05). RESULTS There were significant differences between the 4 groups for ultimate flexural strength (P<.001) and resistance to cyclic loading (P=.002). The volume of filler wire added was a significant predictor of ultimate flexural strength (P=.03), and was a borderline determinant of the number of cycles to failure at 200 N (P=.05). Each laser weld pass with filler wire roughly doubled the ultimate flexural strength and fatigue resistance of the joint relative to the previous weld. Tungsten inert gas welding with efficient argon shielding deposited the most filler wire and produced the strongest and most fatigue-resistant joints. CONCLUSION The ultimate flexural strength and fatigue resistance of cantilevered joints in laser-welded titanium prostheses are improved by the use of filler wire. Tungsten inert gas welding with efficient argon shielding can be used in situations when a high-strength joint is required.
Collapse
Affiliation(s)
- Christopher N Hart
- School of Dental Science, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, 711 Elizabeth Street, Melbourne, Victoria 3000, Australia.
| | | |
Collapse
|
48
|
Abstract
PURPOSE This study investigated the effect of argon gas shielding on the strengths of laser-welded cast Ti and Ti-6Al-7Nb and compared the results to those of two dental casting alloys. MATERIALS AND METHODS Cast plates of Ti, Ti-6Al-7Nb, gold, and Co-Cr alloy were prepared. After polishing the surfaces to be welded, two plates were abutted and welded using Nd:YAG laser at a pulse duration of 10 ms, spot diameter of 1 mm, and voltage of 200 V. Five specimens were prepared for each metal by bilaterally welding them with three or five spots either with or without argon shielding. The failure load and percent elongation were measured at a crosshead speed of 1.0 mm/min. RESULTS The factor of argon shielding significantly affected the failure load and elongation of the laser-welded specimens. The failure loads of argon-shielded laser-welded CP Ti and Ti-6Al-7Nb were greater compared with the failure loads of specimens welded without argon shielding for both three- and five-spot welding. Regardless of argon shielding, the failure loads of the laser-welded gold alloy were approximately half that of the control specimens. In contrast, the failure loads of the nonshielded laser-welded Co-Cr alloy were greater. The percent elongations positively correlated with the failure loads. CONCLUSIONS The use of argon shielding is necessary for effective laser-welding of CP Ti and Ti-6Al-7Nb but not for gold and Co-Cr alloy.
Collapse
Affiliation(s)
- Ikuya Watanabe
- Department of Biomaterials Science, Baylor College of Dentistry, Texas A&M University System Health Science Center, Dallas, 75246, USA.
| | | |
Collapse
|
49
|
Baba N, Watanabe I. Penetration depth into dental casting alloys by Nd:YAG laser. J Biomed Mater Res B Appl Biomater 2005; 72:64-8. [PMID: 15389499 DOI: 10.1002/jbm.b.30117] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This study investigated the effect of laser-beam welding conditions [voltage (V) and spot diameter (mm)] on the penetration depth into dental casting alloys. Castings (3.0 mm x 8.0 mm x 50 mm) were prepared from the metals used in this study: commercially pure titanium (CP Ti), Ti-6Al-4V, Ti-6Al-7Nb, cobalt-chromium alloy (Co-Cr) and Type IV gold alloy. Two cast blocks of each metal were butted against one another at the 8.0 x 50-mm surfaces. They were then welded at their interface under the following conditions: voltage of 160-340 V, spot diameter of 0.4-1.6 mm, and pulse duration of 10 ms. After laser welding, the blocks were separated, and the penetration depth into each alloy was measured. The data were analyzed with the use of ANOVA at the p < 0.05 level of significance. The penetration depths were as follows: CP Ti (0.29-6.45 mm), Ti-6Al-4V (0.32-5.24 mm), Ti-6Al-7Nb (0.34-5.65 mm), Co-Cr (0.24-6.15 mm), and Type IV gold alloy (0.12-5.22 mm). The voltage and spot diameter affected the penetration depth into the metals tested. When the voltage increased and the spot diameter decreased, the penetration depth increased for each metal. Selecting suitable conditions for laser welding to obtain sufficient penetration depth for the optimal thickness of the metal is important when welding prostheses.
Collapse
Affiliation(s)
- N Baba
- Department of Developmental and Reconstructive Medicine, Division of Fixed Prosthodontics and Oral Rehabilitation, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan.
| | | |
Collapse
|
50
|
Uysal H, Kurtoglu C, Gurbuz R, Tutuncu N. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs. J Prosthet Dent 2005; 93:235-44. [PMID: 15775924 DOI: 10.1016/j.prosdent.2004.11.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
STATEMENT OF PROBLEM The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. PURPOSE This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. MATERIAL AND METHODS Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. RESULTS Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72 MPa, 4.8 +/- 0.7%, 353 +/- 23 KHN, respectively, for the test group. The differences between the groups were significant for all mechanical properties ( P <.05). For both models, the FEA revealed that maximum principal stresses were concentrated at the framework-weld junction but did not exceed the UTS of the weld joint. CONCLUSION Within the constraints of the finite element models, mechanical failure of the welded joint between the support and the framework may not be expected under biomechanical conditions simulated in this study.
Collapse
Affiliation(s)
- Hakan Uysal
- Department of Prosthodontics, Faculty of Dentistry, Cukurova University, Adana, Turkey.
| | | | | | | |
Collapse
|