1
|
Huang Y, Zhang F, Zhang Y, Chen R, Lü X. Combination of gene/protein and metabolite multiomics to reveal biomarkers of nickel ion cytotoxicity and the underlying mechanism. Regen Biomater 2024; 11:rbae079. [PMID: 39022125 PMCID: PMC11254314 DOI: 10.1093/rb/rbae079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 06/11/2024] [Accepted: 06/19/2024] [Indexed: 07/20/2024] Open
Abstract
Biomarkers have been applied for toxicity assessment of biomaterials due to their advantages. However, research on biomarkers for biomaterials is still in its early stages. There is a lack of integrated analysis in biomarker research based on multiomics studies. Herein, we report a new approach for combining of gene/protein and metabolite multiomics to reveal biomarkers of nickel ion (Ni2+) cytotoxicity and the underlying mechanism. Firstly, differentially expressed genes and proteins were compared to screen gene/protein pairs exhibiting consistent differential expression within the same Ni2+-treated groups. Next, metabolic pathway analysis was carried out to reveal pathways in which gene/protein pairs and metabolites showed upstream and downstream relationships. Important networks composed of gene/protein pairs, metabolites and metabolic pathways and candidate biomarkers were subsequently identified. Through expression level and function validation, the gene/protein/metabolite biomarkers were confirmed, and the underlying mechanism was revealed: Ni2+ influenced the expression of the Rrm2 gene biomarker, which subsequently affected the expression of the RRM2 protein biomarker. These changes in turn impacted the levels of uric acid and uridine metabolite biomarkers, ultimately inhibiting DNA synthesis, suppressing cell proliferation, increasing intracellular ROS levels and reducing ATP content.
Collapse
Affiliation(s)
- Yan Huang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Fudan Zhang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Yajing Zhang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Rong Chen
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Xiaoying Lü
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
2
|
Hasan J, Bright R, Hayles A, Palms D, Zilm P, Barker D, Vasilev K. Preventing Peri-implantitis: The Quest for a Next Generation of Titanium Dental Implants. ACS Biomater Sci Eng 2022; 8:4697-4737. [PMID: 36240391 DOI: 10.1021/acsbiomaterials.2c00540] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Titanium and its alloys are frequently the biomaterial of choice for dental implant applications. Although titanium dental implants have been utilized for decades, there are yet unresolved issues pertaining to implant failure. Dental implant failure can arise either through wear and fatigue of the implant itself or peri-implant disease and subsequent host inflammation. In the present report, we provide a comprehensive review of titanium and its alloys in the context of dental implant material, and how surface properties influence the rate of bacterial colonization and peri-implant disease. Details are provided on the various periodontal pathogens implicated in peri-implantitis, their adhesive behavior, and how this relationship is governed by the implant surface properties. Issues of osteointegration and immunomodulation are also discussed in relation to titanium dental implants. Some impediments in the commercial translation for a novel titanium-based dental implant from "bench to bedside" are discussed. Numerous in vitro studies on novel materials, processing techniques, and methodologies performed on dental implants have been highlighted. The present report review that comprehensively compares the in vitro, in vivo, and clinical studies of titanium and its alloys for dental implants.
Collapse
Affiliation(s)
- Jafar Hasan
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia
| | - Richard Bright
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Andrew Hayles
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Dennis Palms
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| | - Peter Zilm
- Adelaide Dental School, University of Adelaide, Adelaide, 5005, South Australia, Australia
| | - Dan Barker
- ANISOP Holdings, Pty. Ltd., 101 Collins St, Melbourne VIC, 3000 Australia
| | - Krasimir Vasilev
- Academic Unit of STEM, University of South Australia, Mawson Lakes, SA 5095, Australia.,College of Medicine and Public Health, Flinders University, Bedford Park 5042, South Australia, Australia
| |
Collapse
|
3
|
Kunrath MF, Muradás TC, Penha N, Campos MM. Innovative surfaces and alloys for dental implants: What about biointerface-safety concerns? Dent Mater 2021; 37:1447-1462. [PMID: 34426019 DOI: 10.1016/j.dental.2021.08.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 08/04/2021] [Accepted: 08/06/2021] [Indexed: 02/06/2023]
Abstract
OBJECTIVES The present review article aimed to discuss the recent technologies employed for the development of dental implants, mainly regarding innovative surface treatments and alternative alloys, emphasizing the bio-tribocorrosion processes. METHODS An electronic search applying specific MeSH terms was carried out in PubMed and Google Scholar databases to collect data until August 2021, considering basic, pre-clinical, clinical and review studies. The relevant articles (n=111), focused on innovative surface treatments for dental implants and their potential undesirable biological effects, were selected and explored. RESULTS Novel texturization methodologies for dental implants clearly provided superficial and structural atomic alterations in micro- and nanoscale, promoting different mechanical-chemical interactions when applied in the clinical set. Some particulate metals released from implant surfaces, their degradation products and/or contaminants exhibited local and systemic reactions after implant installation and osseointegration, contributing to unexpected treatment drawbacks and adverse effects. Therefore, there is an urgent need for development of pre-clinical and clinical platforms for screening dental implant devices, to predict the biointerface reactions as early as possible during the development phases. SIGNIFICANCE Modern surface treatments and innovative alloys developed for dental implants are not completely understood regarding their integrity during long-term clinical function, especially when considering the bio-tribocorrosion process. From this review, it is possible to assume that degradation and contamination of dental surfaces might be associated within peri-implant inflammation and cumulative long-lasting systemic toxicity. The in-depth comprehension of the biointerface modifications on these novel surface treatments might preclude unnecessary expenses and postoperative complications involving osseointegration failures.
Collapse
Affiliation(s)
- Marcel F Kunrath
- Programa de Pós-Graduação em Odontologia, Escola de Ciências da Saúde e da Vida, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil; Centro de Pesquisa em Toxicologia e Farmacologia, Escola de Ciências da Saúde e da Vida, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | - Thaís C Muradás
- Centro de Pesquisa em Toxicologia e Farmacologia, Escola de Ciências da Saúde e da Vida, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil; Programa de Pós-Graduação em Medicina e Ciências da Saúde, Escola de Medicina, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil
| | | | - Maria M Campos
- Programa de Pós-Graduação em Odontologia, Escola de Ciências da Saúde e da Vida, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil; Centro de Pesquisa em Toxicologia e Farmacologia, Escola de Ciências da Saúde e da Vida, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil; Programa de Pós-Graduação em Medicina e Ciências da Saúde, Escola de Medicina, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, RS, Brazil
| |
Collapse
|
4
|
Nimeri G, Curry J, Berzins D, Liu D, Ahuja B, Lobner D. Cytotoxic evaluation of two orthodontic silver solder materials on human periodontal ligament fibroblast cells and the effects of antioxidant and antiapoptotic reagents. Angle Orthod 2021; 91:349-355. [PMID: 33492364 DOI: 10.2319/050620-405.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 11/01/2020] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To evaluate the cytotoxicity effects of two different solder materials used for orthodontic appliances on human periodontal ligament fibroblast (HPLF) cells, and to determine whether the mechanism of toxicity may involve oxidative stress and apoptosis. MATERIALS AND METHODS The silver solder samples (Leone and Summit) were soldered to orthodontic stainless steel bands and exposed to HPLF cells via cell culture inserts for 48 hours. Cytotoxicity effect of the soldered materials on HPLF cells was measured via tetrazolium salt 3-(4,5-dimethylthiazol-2-yl)-2, 5-diphenyltetrazolium bromide (MTT) colorimetric assay (n = 10/sample) and morphological observation. In addition, the mechanism of cytotoxicity of the most toxic silver solder was investigated using both a caspase inhibitor Z-VAL-Ala-Asp-flu-oromethylketone (ZVAD-fmk) and the free radical scavenger Trolox (n = 8/sample). Statistical analysis was performed using one-way analysis of variance with a Bonferroni test. P < .05 was considered statistically significant. RESULTS Compared to the control (no treatment, cells only), both silver solders were cytotoxic (P < .001). The bands alone were significantly cytotoxic compared to the control. There was a significant difference in cytotoxicity between the stainless steel bands alone and the Summit silver solder (P < .001), but not the Leone silver solder. The Summit silver solder was more cytotoxic than the Leone silver solder (P < .05). MTT results were supported by the microscopic morphological changes of the HPLF cells. Neither ZVAD-fmk nor Trolox provided significant protection. CONCLUSIONS The two silver solder materials demonstrated different levels of cytotoxicity, and neither oxidative stress nor apoptosis is involved in the mechanism of cytotoxicity.
Collapse
|
5
|
Immunological Responses to Total Hip Arthroplasty. J Funct Biomater 2017; 8:jfb8030033. [PMID: 28762999 PMCID: PMC5618284 DOI: 10.3390/jfb8030033] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2017] [Revised: 07/19/2017] [Accepted: 07/25/2017] [Indexed: 12/12/2022] Open
Abstract
The use of total hip arthroplasties (THA) has been continuously rising to meet the demands of the increasingly ageing population. To date, this procedure has been highly successful in relieving pain and restoring the functionality of patients’ joints, and has significantly improved their quality of life. However, these implants are expected to eventually fail after 15–25 years in situ due to slow progressive inflammatory responses at the bone-implant interface. Such inflammatory responses are primarily mediated by immune cells such as macrophages, triggered by implant wear particles. As a result, aseptic loosening is the main cause for revision surgery over the mid and long-term and is responsible for more than 70% of hip revisions. In some patients with a metal-on-metal (MoM) implant, metallic implant wear particles can give rise to metal sensitivity. Therefore, engineering biomaterials, which are immunologically inert or support the healing process, require an in-depth understanding of the host inflammatory and wound-healing response to implanted materials. This review discusses the immunological response initiated by biomaterials extensively used in THA, ultra-high-molecular-weight polyethylene (UHMWPE), cobalt chromium (CoCr), and alumina ceramics. The biological responses of these biomaterials in bulk and particulate forms are also discussed. In conclusion, the immunological responses to bulk and particulate biomaterials vary greatly depending on the implant material types, the size of particulate and its volume, and where the response to bulk forms of differing biomaterials are relatively acute and similar, while wear particles can initiate a variety of responses such as osteolysis, metal sensitivity, and so on.
Collapse
|
6
|
Cytotoxic outcomes of orthodontic bands with and without silver solder in different cell lineages. Am J Orthod Dentofacial Orthop 2017; 151:957-963. [DOI: 10.1016/j.ajodo.2016.10.030] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Revised: 10/01/2016] [Accepted: 10/01/2016] [Indexed: 11/18/2022]
|
7
|
Cytotoxicity and anti-inflammatory effects of zinc ions and eugenol during setting of ZOE in immortalized human oral keratinocytes grown as three-dimensional spheroids. Dent Mater 2016; 32:e93-104. [DOI: 10.1016/j.dental.2016.01.003] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 10/22/2015] [Accepted: 01/15/2016] [Indexed: 11/22/2022]
|
8
|
Tewari BB. The stability constants of ML and ML2 complexes of Be(II) and Co(II)—isoleucine according to paper ionophoretic data. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A 2014. [DOI: 10.1134/s0036024414040281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
9
|
Amini F, Rahimi H, Morad G, Mollaei M. The effect of stress on salivary metal ion content in orthodontic patients. Biol Trace Elem Res 2013; 155:339-43. [PMID: 24026442 DOI: 10.1007/s12011-013-9812-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2013] [Accepted: 09/01/2013] [Indexed: 01/09/2023]
Abstract
Psychological stress can alter the environment in favor of corrosion of orthodontic alloys by changing the properties of saliva. This study aimed to assess the effect of stress induction on salivary nickel and chromium content in fixed orthodontic patients. Thirty patients were enrolled in this experiment. Saliva sample collection was performed at four time points: T1, before insertion of orthodontic appliances; T2, 3 months after the initiation of orthodontic treatment, before induction of stress; T3, 15 min following the induction of stress by Trier Social Stress Test; and T4, 30 min following the induction of stress. Ion content was measured by atomic absorption spectrophotometry. The obtained data were analyzed by repeated measures analysis of variance (ANOVA) and post hoc Bonferroni test. The mean amount of salivary nickel increased from 11.9 ± 5.1 μg/L at T1 to 14.1 ± 5.3 μg/L at T4. This increase was found significant only at T4 comparing to T1. The average salivary chromium content changed from 4.1 ± 2.3 μg/L at T1 to 5.1 ± 3.3 μg/L at T4. None of the differences were significant for chromium. In conclusion, induction of stress in this study led to a significant increase in nickel release from orthodontic appliances into saliva. The salivary chromium content however was not significantly altered, yet gradually increased.
Collapse
Affiliation(s)
- Fariborz Amini
- Department of Orthodontics, Islamic Azad University, Dental Branch, Tehran, Iran
| | | | | | | |
Collapse
|
10
|
Schröck K, Schneider H, Lutz J, Hacker MC, Mändl S, Kamprad M, Schulz-Siegmund M. Cytocompatibility of nitrogen plasma ion immersed medical cobalt-chromium alloys. J Biomed Mater Res A 2013; 102:1744-54. [DOI: 10.1002/jbm.a.34842] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2013] [Revised: 05/30/2013] [Accepted: 06/05/2013] [Indexed: 01/11/2023]
Affiliation(s)
- Kathleen Schröck
- Translational Centre for Regenerative Medicine (TRM), Universität Leipzig; 04103 Leipzig Germany
- Pharmaceutical Technology, Institute of Pharmacy; Universität Leipzig; 04317 Leipzig Germany
| | - Heike Schneider
- Translational Centre for Regenerative Medicine (TRM), Universität Leipzig; 04103 Leipzig Germany
| | - Johanna Lutz
- Translational Centre for Regenerative Medicine (TRM), Universität Leipzig; 04103 Leipzig Germany
- Leibniz-Institut für Oberflächenmodifizierung e.V. (IOM); 04318 Leipzig Germany
| | - Michael C. Hacker
- Pharmaceutical Technology, Institute of Pharmacy; Universität Leipzig; 04317 Leipzig Germany
| | - Stephan Mändl
- Leibniz-Institut für Oberflächenmodifizierung e.V. (IOM); 04318 Leipzig Germany
| | - Manja Kamprad
- Institute of Clinical Immunology and Transfusion Medicine, University Hospital Leipzig; 04103 Leipzig Germany
| | | |
Collapse
|
11
|
Qiao Y, Ma L. Quantification of metal ion induced DNA damage with single cell array based assay. Analyst 2013; 138:5713-8. [DOI: 10.1039/c3an00967j] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
12
|
D'Antò V, Valletta R, Amato M, Schweikl H, Simeone M, Paduano S, Rengo S, Spagnuolo G. Effect of nickel chloride on cell proliferation. Open Dent J 2012. [PMID: 23198004 PMCID: PMC3504722 DOI: 10.2174/1874210601206010177] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Objective: Metal alloys used in dentistry and in other biomedical fields may release nickel ions in the oral environment. The release of nickel might influence the normal biological and physiological processes, including tissue wound healing, cell growth and proliferation. The aim of this study was to evaluate in vitro the effects of nickel ions on cell cycle, viability and proliferation. Materials and Methods: Human osteosarcoma cells (U2OS) and human keratinocytes (HaCat) were exposed to different nickel chloride (NiCl2) concentrations (0 - 5mM) for various periods exposure. The viability of cultured cells was estimated by flow cytometry using Annexin V-FITC and Propidium Iodide (PI). Cell proliferation was evaluated by using carboxyfluorescein diacetate succinimidyl ester (CFDA-SE) and flow cytometry. Finally, the effects of NiCl2 on cell cycle were assessed and quantified by flow cytometry. Statistical analysis was performed by means of ANOVA followed by Tukey’s test. Results: NiCl2 induced a dose and time dependent decrease in cell viability. After 24h, 1mM NiCl2 caused a similar and significant reduction of viability in U2OS and HaCat cells, while higher NiCl2 concentrations and longer exposure times showed a reduced cytotoxic effect in HaCat as compared to U2OS cells. Exposure to NiCl2 caused a dose- and time-dependent inhibition of cell proliferation in both cell lines tested, with a prominent effect on U2OS cells. Furthermore, both cell lines exposed to NiCl2 exhibited significant changes in cell cycle distribution after 24h exposure 2mM NiCl2, as compared to untreated cells (p<0.05). Conclusion: Our results indicate that release of nickel ions may affect cell proliferation. The inhibition of cell growth by NiCl2 is mediated by both cell cycle arrest and by induction of cell death.
Collapse
Affiliation(s)
- Vincenzo D'Antò
- Department of Oral and Maxillofacial Sciences, University of Naples "Federico II", Napoli, Italy
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Galeone A, Vecchio G, Malvindi MA, Brunetti V, Cingolani R, Pompa PP. In vivo assessment of CdSe-ZnS quantum dots: coating dependent bioaccumulation and genotoxicity. NANOSCALE 2012; 4:6401-6407. [PMID: 22951747 DOI: 10.1039/c2nr31826a] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Semiconductor nanocrystals, or Quantum Dots (QDs), have gained considerable attention due to their unique size-dependent optical and electronic properties that make them attractive for a wide range of applications, including biology and nanomedicine. Their widespread use, however, poses urgent questions about their potential toxicity, especially because of their heavy metal composition that could cause harmful effects to human health and environment. In this work, we evaluated in vivo the long-term toxicity of CdSe-ZnS QDs with different surface coatings, probing oral administration in the model system Drosophila melanogaster. In particular, we found that all the differently coated QDs significantly affect the lifespan of treated Drosophila populations and induce a marked increase in reactive oxygen species (ROS) levels. Furthermore, we observed that these QDs induce severe genotoxic effects and increased rate of apoptosis in Drosophila haemocytes. These toxic effects were found to be mainly related to the in vivo degradation of QDs with consequent release of Cd(2+) ions, while the coating of QDs can modulate their bioaccumulation in the organism, partly decreasing their overall toxicity.
Collapse
Affiliation(s)
- A Galeone
- Istituto Italiano di Tecnologia (IIT), Center for Bio-Molecular Nanotechnologies@UniLe, Via Barsanti - 73010, Arnesano, Lecce, Italy
| | | | | | | | | | | |
Collapse
|
14
|
Molecular and immune toxicity of CoCr nanoparticles in MoM hip arthroplasty. Trends Mol Med 2012; 18:145-55. [PMID: 22245020 DOI: 10.1016/j.molmed.2011.12.002] [Citation(s) in RCA: 123] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Revised: 12/04/2011] [Accepted: 12/08/2011] [Indexed: 12/29/2022]
Abstract
Theoretical, desirable features of second-generation metal-on-metal (MoM) hip prostheses have led to their widespread use. However, the bearing surfaces, consisting of complex cobalt-chromium alloys, are subject to wear and the release of cobalt and chromium (CoCr) nanoparticles. These nanoparticles can reduce cellular viability, induce DNA damage, lead to chromosomal aberrations, and possibly stimulate increased metal hypersensitivity. Clinically, the effects can be both local (soft-tissue reactions) and systemic (arthroprosthetic cobaltism). This review assesses the literature concerning the in vitro and in vivo cytotoxic, genotoxic, and immunotoxic effects of CoCr wear particles, which is increasingly important in view of the large number of MoM arthroplasties performed.
Collapse
|
15
|
McGinley E, Moran G, Fleming G. Base-metal dental casting alloy biocompatibility assessment using a human-derived three-dimensional oral mucosal model. Acta Biomater 2012; 8:432-8. [PMID: 21889621 DOI: 10.1016/j.actbio.2011.08.017] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2011] [Revised: 08/15/2011] [Accepted: 08/17/2011] [Indexed: 02/02/2023]
Abstract
Nickel-chromium (Ni-Cr) alloys used in fixed prosthodontics have been associated with type IV Ni-induced hypersensitivity. We hypothesised that the full-thickness human-derived oral mucosa model employed for biocompatibility testing of base-metal dental alloys would provide insights into the mechanisms of Ni-induced toxicity. Primary oral keratinocytes and gingival fibroblasts were seeded onto Alloderm™ and maintained until full thickness was achieved prior to Ni-Cr and cobalt-chromium (Co-Cr) alloy disc exposure (2-72 h). Biocompatibility assessment involved histological analyses with cell viability measurements, oxidative stress responses, inflammatory cytokine expression and cellular toxicity analyses. Inductively coupled plasma mass spectrometry analysis determined elemental ion release levels. We detected adverse morphology with significant reductions in cell viability, significant increases in oxidative stress, inflammatory cytokine expression and cellular toxicity for the Ni-Cr alloy-treated oral mucosal models compared with untreated oral mucosal models, and adverse effects were increased for the Ni-Cr alloy that leached the most Ni. Co-Cr demonstrated significantly enhanced biocompatibility compared with Ni-Cr alloy-treated oral mucosal models. The human-derived full-thickness oral mucosal model discriminated between dental alloys and provided insights into the mechanisms of Ni-induced toxicity, highlighting potential clinical relevance.
Collapse
|
16
|
Development of a discriminatory biocompatibility testing model for non-precious dental casting alloys. Dent Mater 2011; 27:1295-306. [PMID: 21996445 DOI: 10.1016/j.dental.2011.09.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2011] [Revised: 08/31/2011] [Accepted: 09/21/2011] [Indexed: 11/24/2022]
Abstract
OBJECTIVES To develop an enhanced, reproducible and discriminatory biocompatibility testing model for non-precious dental casting alloys, prepared to a clinically relevant surface finishing condition, using TR146 oral keratinocyte cells. METHODS Comparative biocompatibility was determined following direct and indirect exposure of TR146 cells to two nickel-chromium (Ni-Cr) and a cobalt-chromium (Co-Cr) alloy-discs. The surface roughness of the discs was determined using a contact stylus profilometer and the elemental ion release by inductively coupled plasma mass spectrometry (ICP-MS). Subsequent biocompatibility analysis included cell morphology, cell density measurements with Trypan blue exclusion assay, inflammatory cytokine expression with ELISAs, cellular metabolic activity using XTT and cellular toxicity using lactate dehydrogenase (LDH) release assay. RESULTS TR146 cell morphology was altered following direct and indirect exposure to the Ni-Cr alloys but not the Co-Cr alloy. Significant reductions (all P<0.001) in viable cell density measurements, cellular metabolic activity, significant increases inflammatory cytokine expression and cellular toxicity were observed when TR146 cells were exposed to the Ni-Cr alloys. Significant decreases in cell density measurements, cellular metabolic activity, significant increases inflammatory cytokine expression and cellular toxicity for the Ni-Cr d.Sign(®)15 alloy compared with d.Sign(®)10 alloy were identifiable (all P<0.001). Cellular toxicity was attributed to nickel ion release levels in solution detected by ICP-MS analysis. DISCUSSION Nickel ions from the Ni-Cr alloys permeated the epithelial cells and activated a proinflammatory response, namely IL-1a, IL-8 and PGE2 expression. Further evidence of nickel ioninduced cell death was supported by the decreased biocompatibility of the highest nickel ion releasing alloy (d.Sign(®)15 compared with d.Sign(®)10) and the increased biocompatibility of the Co-Cr (d.Sign(®)30) alloy where nickel ions were absent.
Collapse
|
17
|
Louise McGinley E, Coleman DC, Moran GP, Fleming GJ. Effects of surface finishing conditions on the biocompatibility of a nickel–chromium dental casting alloy. Dent Mater 2011; 27:637-50. [DOI: 10.1016/j.dental.2011.03.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2010] [Revised: 03/23/2011] [Accepted: 03/28/2011] [Indexed: 10/18/2022]
|
18
|
Biocompatibility of orthodontic bands following exposure to dental plaque. J Orofac Orthop 2011; 72:133-40. [PMID: 21503853 DOI: 10.1007/s00056-011-0016-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2010] [Accepted: 12/07/2010] [Indexed: 10/18/2022]
Abstract
OBJECTIVE The aim of this study was to assess the biocompatibility of orthodontic bands following exposure to the human oral environment. METHODS Cell adherence and cell morphology of gingival fibroblasts grown on 32 orthodontic bands were tested. The bands were in place intraorally for 6 to 37 months. RESULTS We observed cell adherence in 76% of the previously plaque-free surfaces. Cell morphology was 50% spherical and 50% elongated. The surfaces that had had plaque attached demonstrated cell adherence in 84% of the given areas; those cells were spherical in 42% and elongated in 58%. CONCLUSION We conclude that individual oral hygiene habits during orthodontic treatment seem to have no effect on the biocompatibility of orthodontic bands, as we failed to discern a difference in either cell adherence or cell morphology in areas with and without prior plaque attachment.
Collapse
|
19
|
The connective tissue response to Ti, NiCr and AgPd alloys. Folia Histochem Cytobiol 2010; 48:339-45. [PMID: 21071336 DOI: 10.2478/v10042-10-0050-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The aim of the study was to compare the connective tissue response of Lewis rats to Ti, NiCr and AgPd alloys. It was found that implants were covered by collagen-rich, well vascularized capsules. Titanium was covered by the thinnest capsule (57 ± 20 μm) and AgPd alloy was covered by the thickest capsule (239 ± 50 μm). The PCNA+ cell prevalence in the capsules was lower for titanium than for AgPd and NiCr. Mast cells formed a gradient to a depth of 1200 μm only for titanium implants. Cells with brown to black silver granules in the cytoplasm were observed close to AgPd implants. The results suggest that titanium implants induce a weaker connective tissue response than implants made from NiCr and AgPd alloys.
Collapse
|
20
|
Wylie C, Davenport A, Cooper P, Shelton R. Oral Keratinocyte Responses to Nickel-based Dental Casting Alloys In Vitro. J Biomater Appl 2009; 25:251-67. [DOI: 10.1177/0885328209349870] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Adverse reactions of oral mucosa to nickel-based dental casting alloys are probably due to corrosion metal ion release. We exposed H400 oral keratinocytes to two Ni-based dental alloys (Matchmate and Dsign10) as well as NiCl 2 (1—40 μg/mL Ni2+). Alloy derived Ni2+ media concentrations were determined. Direct culture on both alloys resulted in inhibited growth with a greater effect observed for Dsign10 (higher ion release). Indirect exposure of cells to conditioned media from Dsign10 negatively affected cell numbers (~64% of control by 6 days) and morphology while Matchmate-derived media did not. Exposure to increasing NiCl2 negatively affected cell growth and morphology, and the Granulocyte-macrophage colony-stimulating factor (GM-CSF) transcript was significantly up-regulated in cells following direct and indirect exposure to Dsign10. NiCl2 exposure up-regulated all cytokine transcripts at 1 day. At day 6, IL-1β and IL-8 transcripts were suppressed while GM-CSF and IL-11 increased with Ni2+ dose. Accumulation of Ni2+ ions from alloys in oral tissues may affect keratinocyte viability and chronic inflammation.
Collapse
Affiliation(s)
- C.M. Wylie
- School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - A.J. Davenport
- School of Metallurgy and Materials, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK
| | - P.R. Cooper
- Biomaterials Unit, School of Dentistry, University of Birmingham, St Chads Queensway, Birmingham, B4 6NN, UK
| | - R.M. Shelton
- Biomaterials Unit, School of Dentistry, University of Birmingham, St Chads Queensway, Birmingham, B4 6NN, UK,
| |
Collapse
|
21
|
Stephan CH, Sauvé S, Fournier M, Brousseau P. Use of proliferation tests to evaluate the effects of complexing agents on beryllium toxicity. J Appl Toxicol 2008; 29:27-35. [PMID: 18785683 DOI: 10.1002/jat.1378] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Occupational exposure to beryllium may cause chronic beryllium disease (CBD), a granulomatous interstitial pneumonitis caused by a cell-mediated immune response with delayed hypersensitivity initiated by an electrostatic interaction with the MHC class II human leukocyte antigen (HLA). Increased research efforts focus on the development of a CBD treatment by chelation therapy. This work presents an in vitro evaluation of the beneficial effects of beryllium chelation with different organic substrates. We have used a standard beryllium lymphocyte proliferation test (BeLPT) adapted for mouse splenocytes. Three complexing agents, 4,5-dihydroxy-1,3-benzenedisulfonic acid (tiron), nitrilotripropionic acid (NTP) and nitrilotriacetic acid (NTA), were tested using different protocols of the splenocyte proliferation test (SPT). We studied their corrective effect (beryllium pre-exposed splenocytes), their protective effect (ligand pre-exposed splenocytes) and their combined effects at fixed Be:L ratio of 1:2, at fixed Be concentration and at fixed L concentration. We also studied the effect of tiron in preventing splenocyte sensitization to beryllium. All three complexing agents showed a corrective effect and proved efficient in the combined effects, except NTA in the fixed Be:L ratio. Only NTP and tiron showed a significant protection at lower beryllium concentrations, while NTA was not significant. Splenocytes pre-exposed to chelated beryllium did not show sensitization while splenocytes pre-exposed to beryllium were sensitized. We observed a strong correlation between the efficiency of the complexing agent and its affinity towards beryllium. Both tiron and NTP showed a similar affinity towards the beryllium ion that is 10(7) higher than that of NTA.
Collapse
Affiliation(s)
- Chadi H Stephan
- Department of Chemistry, Université de Montréal, succ. Centre-Ville, Montréal, QC, Canada H3C 3J7
| | | | | | | |
Collapse
|
22
|
Fu J, Liang X, Chen Y, Tang L, Zhang QH, Dong Q. Oxidative stress as a component of chromium-induced cytotoxicity in rat calvarial osteoblasts. Cell Biol Toxicol 2007; 24:201-12. [PMID: 18027092 DOI: 10.1007/s10565-007-9029-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2007] [Accepted: 05/17/2007] [Indexed: 11/26/2022]
Abstract
It has been documented that medical prosthetic alloys release metal ions into surrounding tissues and cause cytotoxicity, but the mechanisms remain undefined. In that regard the cellular oxidative stress may be a common pathway in cellular responses to metal ions. The objective of this study was to approach the hypothesis that oxidative stress mediates chromium-induced cytotoxicity in rat calvarial osteoblasts. Osteoblasts were exposed to different concentrations of Cr6+ or Cr3+ (5-20 microM) in the presence or absence of the antioxidant N-acetyl-cysteine (NAC; 1-5 mM). Cellular viability, differentiation, and intracellular ultrastructural alterations were evaluated by MTT assay, alkaline phosphatase (ALP) activity assay, and transmission electron microscopy. Cellular oxidative stress was evaluated by intracellular reactive oxygen species (ROS) production. ROS production was monitored by the oxidation-sensitive fluorescent probe 2'7'-dichlorofluorescin diacetate (DCFH-DA). A time- and concentration- dependent increased cytotoxicity, time-dependent increased intracellular ROS production were indicated on exposure to Cr6+. Pretreatment of osteoblasts with 1-5 mM NAC afforded dose-dependent cytoprotective effects against Cr6+-induced cytotoxicity in osteoblasts. NAC decreased the level of intracellular ROS induced by Cr6+, too. While Cr3+ and NAC did not have any significant effects on osteoblasts (5-20 microM). These results suggest that oxidative stress is involved in Cr6+-induced cytotoxicity in osteoblasts, and NAC can provide protection for osteoblasts against Cr6+-induced oxidative stress. Cr3+ (5-20 microM) have no significant cytotoxicity in osteoblasts based on the results of this study.
Collapse
Affiliation(s)
- Jun Fu
- Key Laboratory of Oral Biomedical Engineering of Chinese Ministry of Education, West China College of Stomatology, Sichuan University, Chengdu, Sichuan 610041, People's Republic of China
| | | | | | | | | | | |
Collapse
|
23
|
Wylie CM, Shelton RM, Fleming GJP, Davenport AJ. Corrosion of nickel-based dental casting alloys. Dent Mater 2007; 23:714-23. [PMID: 16949144 DOI: 10.1016/j.dental.2006.06.011] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2005] [Revised: 03/31/2006] [Accepted: 06/20/2006] [Indexed: 10/24/2022]
Abstract
OBJECTIVES To study the microstructure, corrosion behaviour and cell culture response of two nickel-based dental casting alloys before and after a heat treatment to simulate porcelain firing. METHODS The microstructure was studied using scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). Corrosion behaviour was evaluated by electrochemical measurements in artificial saliva at different values of pH in the presence of a crevice. 3T3 mouse fibroblasts were exposed indirectly to alloy specimens and the number of viable cells counted after 3 and 6 days compared to a control culture. RESULTS Small changes in microstructure were observed after heat treatment but had a negligible effect on the corrosion properties in the conditions tested. The alloy with a lower bulk level of Cr (12.6 wt.%) showed lower corrosion resistance, indicated by an increased passive current density and this stability was greatly reduced at pH 2.5, where crevice corrosion was observed. Selective dissolution occurred at regions within the microstructure containing lower levels of Cr and Mo. Furthermore, the proliferation of 3T3 mouse fibroblasts was reduced (p<0.05) when exposed indirectly to this alloy. The alloy containing a higher level of Cr (25 wt.%) showed superior corrosion resistance, which was associated with a more uniform distribution of Cr in the alloy microstructure. SIGNIFICANCE The presence of crevices combined with an inhomogeneous distribution of Cr in the microstructure can lead to accelerated corrosion of Ni-based alloys with lower Cr contents. This effect can be avoided by increasing the Cr content of the alloy.
Collapse
Affiliation(s)
- Christopher M Wylie
- Department of Metallurgy and Materials, University of Birmingham, Birmingham B15 2TT, UK
| | | | | | | |
Collapse
|
24
|
Messer RLW, Mickalonis J, Adams Y, Tseng WY. Corrosion rates of stainless steel under shear stress measured by a novel parallel-plate flow chamber. J Biomed Mater Res B Appl Biomater 2006; 76:273-80. [PMID: 16080202 DOI: 10.1002/jbm.b.30367] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A unique parallel-plate flow chamber has been engineered to assess the corrosion properties of implant materials in biological environments under shear flow. This parallel-plate flow chamber provides a novel approach to investigate hypotheses regarding cellular-material-mechanical-force interactions that influence the success or failure of implant devices. The results of the current study demonstrated that physiological stresses (0.5-50 dynes/cm2) from laminar flow from cell culture media did not significantly alter corrosion rates of stainless steel, providing baseline information for an extensive study of the cellular-material-mechanical-force interactions. Furthermore, this study demonstrated that this device is electrochemically stable and provides reproducible results within test parameters. In addition, the results were not significantly different from corrosion tests on bulk samples. Therefore, this system will be useful for investigating cell-material interactions under shear stress for implant alloys or other opaque materials. This information is currently lacking. The results of the present study also support further development of this test system to assess cellular responses to these materials under shear stresses.
Collapse
Affiliation(s)
- Regina L W Messer
- Department of Oral Biology and Maxillofacial Pathology, Medical College of Georgia, Augusta, Georgia, USA.
| | | | | | | |
Collapse
|
25
|
Trombetta D, Mondello MR, Cimino F, Cristani M, Pergolizzi S, Saija A. Toxic effect of nickel in an in vitro model of human oral epithelium. Toxicol Lett 2005; 159:219-25. [PMID: 16011880 DOI: 10.1016/j.toxlet.2005.05.019] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2004] [Revised: 05/11/2005] [Accepted: 05/17/2005] [Indexed: 11/17/2022]
Abstract
Nickel is a metal widely employed in dental alloys, and due to peculiar properties of certain nickel-based materials, it cannot be substituted with other metals in some applications. The release of nickel ions from dental alloys placed into long-term contact with mouth soft tissues is alarming because of the toxic, immunological and carcinogenic effects which have been well documented for some nickel compounds. Our study was focussed on the toxic effects induced "in vitro" on human oral epithelium by the exposure to low concentrations of nickel chloride. In view of this, we adopted a three-dimensional model of epithelial cultures, reconstituted from TR 146 cells, resembling the physiological environment of the oral cavity and useful for biocompatibility testing. The effects on cell viability, apoptosis, cellular content of reduced and oxidized glutathione (GSH and GSSG) and release of prostaglandin E(2) (PGE(2)), interleukin-8 (IL-8) and interleukin-6 (IL-6) were investigated following topical application of a NiCl(2) solution ranging from 7.6mM to 0.05 mM for 72 h. Our findings show that nickel concentrations, which do not significantly modify cell viability and inflammation mediator release, can affect the redox equilibrium and stimulate apoptosis in oral epithelium cells. Further studies are needed to demonstrate the hypothesis that the oxidative imbalance induced by nickel might be implicated in the induction of apoptosis.
Collapse
Affiliation(s)
- Domenico Trombetta
- Department Farmaco-Biologico, School of Pharmacy, University of Messina, Contrada Annunziata, 98168 Messina, Italy
| | | | | | | | | | | |
Collapse
|
26
|
Shrivastava HY, Ravikumar T, Shanmugasundaram N, Babu M, Unni Nair B. Cytotoxicity studies of chromium(III) complexes on human dermal fibroblasts. Free Radic Biol Med 2005; 38:58-69. [PMID: 15589372 DOI: 10.1016/j.freeradbiomed.2004.09.029] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2004] [Accepted: 09/22/2004] [Indexed: 10/26/2022]
Abstract
The cytotoxicity of certain Cr(III) complexes, such as [Cr(salen)(H(2)O)(2)](+), [Cr(edta)(H(2)O)](-), [Cr(en)(3)](3+), [Cr(ox)(3)](3-), [Cr(pic)(3)], and CrCl(3), which differ in ionic character and ligand environment in human dermal skin fibroblasts, has been studied. After 72 h of exposure to 100 microM doses of chromium(III) complexes, the order in which the complexes had an inhibitory effect on cell viability was [Cr(en)(3)](3+) > [Cr(salen)(H(2)O)(2)](+) > [Cr(ox)(3)](3-) > [Cr(edta)(H(2)O)](-) > [Cr(pic)(3)] > CrCl(3). Based on viability studies it was confirmed that [Cr(en)(3)](3+), a triply charged cation, inhibits cell proliferation, and therefore, it was chosen to carry out further investigations. [Cr(en)(3)](3+), at a dose of 50 microM, was found to bring about surface morphological changes, evidenced by cellular blebbing and spike formation accompanied by nuclear damage. TEM analysis revealed substantial intracellular damage to fibroblasts in terms of the formation of apoptotic bodies and chromatin condensation, thus reflecting cell death. FACS analysis further revealed DNA damage by formation of a sub-G(1) peak with 84.2% DNA as aneuploid DNA and arrest of the G(2) / M phase of the cell cycle. Cellular DNA damage was confirmed by agarose gel electrophoresis with the characteristic appearance of a DNA streak in DNA isolated from [Cr(en)(3)](3+)-treated fibroblasts. The proposed mechanism suggests the plausible role of Cr(V), formed as a result of oxidation of Cr(III) by cellular oxidative enzymes, in the cytotoxic response. Consequently, any Cr(III) complex that is absorbed by cells and can be oxidized to Cr(V) must be considered a potential carcinogen. This has potential implications for the increased use of Cr(III) complexes as dietary supplements and highlights the need to consider the cytotoxicity and genotoxicity of a variety of Cr(III) complexes and to understand the potential hazards of Cr(III) complexes encountered in research laboratories.
Collapse
Affiliation(s)
- H Yamini Shrivastava
- Chemical Laboratory, Central Leather Research Institute, Adyar, Chennai 600020, India
| | | | | | | | | |
Collapse
|
27
|
Eisenbarth E, Velten D, Müller M, Thull R, Breme J. Biocompatibility of β-stabilizing elements of titanium alloys. Biomaterials 2004; 25:5705-13. [PMID: 15147816 DOI: 10.1016/j.biomaterials.2004.01.021] [Citation(s) in RCA: 239] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2003] [Accepted: 01/17/2004] [Indexed: 11/19/2022]
Abstract
In comparison to the presently used alpha + beta titanium alloys for biomedical applications, beta-titanium alloys have many advantageous mechanical properties, such as an improved wear resistance, a high elasticity and an excellent cold and hot formability. This will promote their future increased application as materials for orthopaedic joint replacements. Not all elements with beta-stabilizing properties in titanium alloys are suitable for biomaterial applications-corrosion and wear processes cause a release of these alloying elements to the surrounding tissue. In this investigation, the biocompability of alloying elements for beta- and near beta-titanium alloys was tested in order to estimate their suitability for biomaterial components. Titanium (grade 2) and the implant steel X2CrNiMo18153 (AISI 316 L) were tested as reference materials. The investigation included the corrosion properties of the elements, proliferation, mitochondrial activity, cell morphology and the size of MC3T3-E1 cells and GM7373 cells after 7 days incubation in direct contact with polished slices of the metals. The statistical significance was considered by Weir-test and Lord-test (alpha = 0.05). The biocompatibility range of the investigated metals is (decreasing biocompatibility): niobium-tantalum, titanium, zirconium-aluminium-316 L-molybdenum.
Collapse
Affiliation(s)
- E Eisenbarth
- Universität des Saarlandes, Lehrstuhl für metallische Werkstoffe, D-66041 Saarbrücken, Germany.
| | | | | | | | | |
Collapse
|
28
|
Abstract
Metallic medical devices undergo degradation in vivo and the degradation products affect the chemistry and biological responses of cells and tissues in the immediate vicinity. The responses vary with the metal and cell type. In the current study, we examined the effects of several metals on a human monocytic cell line. Monocytes are important effector cells capable of responding rapidly to inflammatory and immune stimuli in a variety of ways, including production of inflammatory proteins, differential expression of surface adhesion molecules, enhanced phagocytic activity, and activation and differentiation to macrophages. Cells were exposed in the presence of (14)C-acetate to titanium, nickel, chromium, copper, or cobalt or vanadium at concentrations that were subinhibitory or inhibitory based on cellular mitochondrial dehydrogenase activity. Cell lipids were then extracted, separated by thin layer chromatography, and quantitated by liquid scintillation spectrometry. Total cell protein also was measured. Titanium reduced cell protein content at concentrations that were noninhibitory to mitochondrial dehydrogenase activity, whereas neither chromium nor cobalt affected protein amounts at dehydrogenase-inhibitory concentrations. In cells exposed to vanadium, the protein- and dehydrogenase-inhibitory concentrations were similar. The major effects on cell lipids appeared to occur in the neutral lipids, although chromium, cobalt, and titanium produced changes in some major phospholipids. These results suggest that metals differentially affect various metabolic pathways in THP-1 cells, perhaps related to their abilities to enter the cells or interact with the membrane. These alterations to the cells may affect the cells' abilities to respond to various stimuli that can damage the tissues.
Collapse
Affiliation(s)
- George S Schuster
- Department of Oral Biology and Maxillofacial Pathology, Medical College of Georgia, School of Dentistry, Augusta, Georgia 30912-1126, USA.
| | | |
Collapse
|
29
|
Noda M, Wataha JC, Lewis JB, Lockwood PE, Komatsu H, Sano H. Hg2+ and Ni2+ alter induction of heat shock protein-72 in THP-1 human monocytes. ACTA ACUST UNITED AC 2003; 67:240-5. [PMID: 14517882 DOI: 10.1002/jbm.a.10100] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The biological liabilities that result from the release of metal ions from biomedical alloys, particularly Ni(2+) and Hg(2+), continue to be a concern. Heat-shock proteins (HSP) are a class of molecular chaperones that may be induced under conditions of cellular stress, including oxidative stress. Our hypothesis was that because Hg(2+) and Ni(2+) alter other cellular stress responses such as glutathione levels and cytokine secretion, these metal ions may alter HSP induction in monocytes, which are key cells in the response of tissues to biomedical alloys. THP-1 monocytes were exposed to sublethal concentrations of Hg(2+) or Ni(2+) for 1 h with or without heat stress (43 degrees C), then allowed to recover at 37 degrees C for 2-6 h. HSP72 was measured using immunoblotting with phosphorimage quantification. Hg(2+) exposures of 2-10 micromol/L induced HSP72 without heat stress. With heat stress, HSP72 levels were altered by Hg(2+) versus heat stress alone. The response depended on the concentration of Hg(2+) and the recovery time. Hg(2+) at 10 micromol/L caused uniformly lower HSP72 levels. Ni(2+) exposures of 20-100 micromol/L did not induce HSP72 without heat stress, but significantly altered heat-induced HSP72 expression, with a significant increase in expression over heat alone at 40 and 100 micromol/L. Results from the current study support the hypothesis that these metal ions can, at concentrations relevant to those released from biomedical alloys, modulate HSP expression in human monocytes. The modulation of HSP expression indicates an early sign of cellular stress that may be important to the overall biological response to biomedical alloys containing and releasing these metal ions.
Collapse
Affiliation(s)
- M Noda
- Section of Cariology, Operative Dentistry, and Endodontology, Department of Oral Health Science, Hokkaido University Graduate School of Dental Medicine, Sapporo 060-8586, Japan
| | | | | | | | | | | |
Collapse
|
30
|
Bumgardner JD, Gerard PD, Geurtsen W, Leyhausen G. Cytotoxicity of precious and nonprecious alloys--experimental comparison of in vitro data from two laboratories. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2003; 63:214-9. [PMID: 11870656 DOI: 10.1002/jbm.10124] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The aim of this investigation was to evaluate and compare the reproducibility of cytotoxicity data generated in two different laboratories using the same testing protocols. A series of dental alloys that are widely used in both countries were chosen. These alloys (five precious, two nonprecious) were wet ground up to 1200 grit SiC, sterilized in 70% ethanol, and extracted in sterile culture medium for 7 days. Pure copper was used as a positive control and Teflonreg and media only were used as negative controls. Test and control samples were randomized and blinded to each laboratory. Cells, primary human gingival fibroblasts, and immortalized 3T3 fibroblasts, were exposed to the extracts for 24 h. Extract cytotoxicity was evaluated spectrophotometrically with the use of a mitochondrial enzyme activity assay. Data were collected from both laboratories, combined, and subjected to a mixed-model analysis of variance. No statistical difference was obtained for the immortalized 3T3 cells, except for two extracts in which differences between the two labs were significant but were still not cytotoxic. Furthermore, no statistical differences were found for the primary cells. These data strongly suggest that cytotoxicity tests performed in different laboratories with the use of the same test materials may lead to comparable results if sample preparation, cells, test procedures, and data analyses are carefully considered.
Collapse
Affiliation(s)
- Joel D Bumgardner
- Biomedical Engineering Program, Mississippi State University, Mississippi State, Mississippi 39762, USA.
| | | | | | | |
Collapse
|
31
|
Messer RLW, Lucas LC. Localization of metallic ions with gingival fibroblast subcellular fractions. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2002; 59:466-72. [PMID: 11774304 DOI: 10.1002/jbm.1262] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Nickel-based alloys have been in use since the 1930s; however, there are concerns regarding the release of metal ions (Be(+2), Cr(+6), Cr(+3), Ni(+2), Mo(+6)) from these alloys into surrounding tissues. Therefore, the objective of this study was to determine the cellular location and accumulation of ions using atomic absorption spectroscopy and correlate location with the cytotoxic, morphologic, and ultrastructural evaluations reported previously. Human gingival fibroblasts were exposed to the metal ions for 72 h. Controlled atomic absorption spectroscopy studies were used to determine the intracellular location of these ions reported as parts per million metal ions per milligram protein. Enzymatic markers were shown to correspond to the appropriate fraction indicating success in fractionation of the gingival fibroblasts. These results correspond with the cytotoxic, morphologic, and ultrastructural alterations reported previously for fibroblasts exposed to these ions. The highest concentration of beryllium ions occurred in the low-density molecule fraction, where lipofuscin granules were found, which has been shown to contain metal ions. The highest concentrations of hexavalent chromium ions occurred in the plasma membrane and nuclear fractions followed by the mitochondria fraction, which is supported by the ions' ability to oxidize to trivalent chromium accumulating at the membrane as well as the alterations in nuclear and mitochondrial function. For trivalent chromium, the highest concentrations occurred in the low-density molecule and the plasma membrane fractions, which correlates with the ions' inability to readily cross membranes. The highest concentration of molybdenum ions occurred in the plasma membrane fraction correlating with alterations in membrane morphology and increased numbers of myelin figures. The highest concentration of nickel ions was associated with the cytosol fraction where lipid droplets seen in the transmission electron micrographs were located. The current study demonstrates that a successful subcellular fractionation was obtained on gingival fibroblasts and that the location of metallic ions within the fractions correlated with cellular alterations reported previously.
Collapse
Affiliation(s)
- Regina L W Messer
- Medical College of Georgia, Department of Oral Biology and Maxillofacial Pathology, Augusta, Georgia 30912, USA.
| | | |
Collapse
|
32
|
Babich H, Sinensky MC. Indirect cytotoxicity of dental materials: a study with Transwell inserts and the neutral red uptake assay. Altern Lab Anim 2001; 29:9-13. [PMID: 11178571 DOI: 10.1177/026119290102900101] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A modification of the Transwell insert methodology was evaluated by using the neutral red uptake (NRU) assay in a cytotoxicity test. The Transwell insert methodology was developed to assess the biocompatibility of solid materials used in dentistry and, when initially designed, used the release of radiochromium ((51)Cr) in the cytotoxicity assay. Another aim of this study was to evaluate different exposure regimes with which to assess cytotoxicity. The exposure regimes included: a 1-hour exposure in buffer followed by a 24-hour incubation in growth medium; a 2-hour exposure in buffer followed by a 24-hour incubation in growth medium; a 24-hour exposure in serum-limited medium; and a 24-hour exposure in a serum-sufficient medium. The bioindicator target was the Smulow-Glickman (S-G) human gingival cell line and the biomaterials were dental restoratives. The Transwell insert methodology with the NRU cytotoxicity assay as the cytotoxicity endpoint was effective in differentiating the potencies of the dental restoratives; a 2-hour exposure in buffer and a 24-hour exposure in serum-limited medium were the exposure regimes that most clearly differentiated the test agents according to their potencies. The sequence of cytotoxicity of the dental restoratives to the S-G cells was Vitremer > Ketac-Molar Aplicap > Flow-It.
Collapse
Affiliation(s)
- H Babich
- Department of Biology, Stern College for Women, Yeshiva University, 245 Lexington Avenue, New York, NY 10016, USA
| | | |
Collapse
|
33
|
Messer RL, Doeller JE, Kraus DW, Lucas LC. An investigation of fibroblast mitochondria enzyme activity and respiration in response to metallic ions released from dental alloys. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH 2000; 50:598-604. [PMID: 10756319 DOI: 10.1002/(sici)1097-4636(20000615)50:4<598::aid-jbm16>3.0.co;2-#] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Most cellular functions evaluated for biocompatibility are high-energy processes such as proliferation and therefore are not usually affected before a decrease in energy production is observed. Several studies have shown that metabolic functions are altered at much lower concentrations than several normally used biocompatibility tests such as viability. Therefore, the purpose of this study was to provide an in-depth evaluation of metallic ion effects on mitochondria function and thereby biocompatibility. These studies evaluated the mitochondrial function of human gingival fibroblasts exposed to the salt solutions of ions released from nickel-based dental alloys, particularly beryllium (Be(2+)), chromium (Cr(6+) and Cr(3+)), nickel (Ni(2+)), and molybdenum (Mo(6+)). Mitochondrial function was examined by NADH:CoQ reductase activity, succinate dehydrogenase activity, and oxygen consumption.
Collapse
Affiliation(s)
- R L Messer
- Department of Biomedical Engineering, University of Alabama at Birmingham, 1075 13th Street South, 370 Hoehn, Birmingham, Alabama 35294-4440, USA
| | | | | | | |
Collapse
|