1
|
Calabretta MM, Lopreside A, Montali L, Zangheri M, Evangelisti L, D'Elia M, Michelini E. Portable light detectors for bioluminescence biosensing applications: A comprehensive review from the analytical chemist's perspective. Anal Chim Acta 2022; 1200:339583. [DOI: 10.1016/j.aca.2022.339583] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 02/02/2022] [Accepted: 02/04/2022] [Indexed: 12/11/2022]
|
2
|
Lopreside A, Calabretta MM, Montali L, Zangheri M, Guardigli M, Mirasoli M, Michelini E. Bioluminescence goes portable: recent advances in whole-cell and cell-free bioluminescence biosensors. LUMINESCENCE 2020; 36:278-293. [PMID: 32945075 DOI: 10.1002/bio.3948] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2020] [Revised: 09/03/2020] [Accepted: 09/07/2020] [Indexed: 12/24/2022]
Abstract
Recent advancements in synthetic biology, organic chemistry, and computational models have allowed the application of bioluminescence in several fields, ranging from well established methods for detecting microbial contamination to in vivo imaging to track cancer and stem cells, from cell-based assays to optogenetics. Moreover, thanks to recent technological progress in miniaturized and sensitive light detectors, such as photodiodes and imaging sensors, it is possible to implement laboratory-based assays, such as cell-based and enzymatic assays, into portable analytical devices for point-of-care and on-site applications. This review highlights some recent advances in the development of whole-cell and cell-free bioluminescence biosensors with a glance on current challenges and different strategies that have been used to turn bioassays into biosensors with the required analytical performance. Critical issues and unsolved technical problems are also highlighted, to give the reader a taste of this fascinating and challenging field.
Collapse
Affiliation(s)
- Antonia Lopreside
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy
| | | | - Laura Montali
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy
| | - Martina Zangheri
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy
| | - Massimo Guardigli
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy.,Interdepartmental Centre for Renewable Sources, Environment, Sea and Energy (CIRI FRAME), Alma Mater Studiorum - University of Bologna, Via Sant'Alberto 163, Ravenna, Italy
| | - Mara Mirasoli
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy.,Interdepartmental Centre for Renewable Sources, Environment, Sea and Energy (CIRI FRAME), Alma Mater Studiorum - University of Bologna, Via Sant'Alberto 163, Ravenna, Italy.,INBB, Istituto Nazionale di Biostrutture e Biosistemi, Via Medaglie d'Oro, Rome, Italy
| | - Elisa Michelini
- Department of Chemistry 'Giacomo Ciamician', University of Bologna, Via Selmi 2, Bologna, Italy.,Interdepartmental Centre for Renewable Sources, Environment, Sea and Energy (CIRI FRAME), Alma Mater Studiorum - University of Bologna, Via Sant'Alberto 163, Ravenna, Italy.,Health Sciences and Technologies-Interdepartmental Centre for Industrial Research (HST-ICIR), University of Bologna, via Tolara di Sopra 41/E 40064, Ozzano dell'Emilia, Bologna, Italy
| |
Collapse
|
3
|
Silverman AD, Akova U, Alam KK, Jewett MC, Lucks JB. Design and Optimization of a Cell-Free Atrazine Biosensor. ACS Synth Biol 2020; 9:671-677. [PMID: 32078765 DOI: 10.1021/acssynbio.9b00388] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Recent advances in cell-free synthetic biology have spurred the development of in vitro molecular diagnostics that serve as effective alternatives to whole-cell biosensors. However, cell-free sensors for detecting manmade organic water contaminants such as pesticides are sparse, partially because few characterized natural biological sensors can directly detect such pollutants. Here, we present a platform for the cell-free detection of one critical water contaminant, atrazine, by combining a previously characterized cyanuric acid biosensor with a reconstituted atrazine-to-cyanuric acid metabolic pathway composed of several protein-enriched bacterial extracts mixed in a one pot reaction. Our cell-free sensor detects atrazine within an hour of incubation at an activation ratio superior to previously reported whole-cell atrazine sensors. We also show that the response characteristics of the atrazine sensor can be tuned by manipulating the ratios of enriched extracts in the cell-free reaction mixture. Our approach of utilizing multiple metabolic steps, encoded in protein-enriched cell-free extracts, to convert a target of interest into a molecule that can be sensed by a transcription factor is modular. Our work thus serves as an effective proof-of-concept for a scheme of "metabolic biosensing", which should enable rapid, field-deployable detection of complex organic water contaminants.
Collapse
Affiliation(s)
| | | | | | - Michael C. Jewett
- Interdisciplinary Biological Sciences Program, Northwestern University, Evanston, Illinois 60208, United States
| | - Julius B. Lucks
- Interdisciplinary Biological Sciences Program, Northwestern University, Evanston, Illinois 60208, United States
- Center for Water Research, Northwestern University, Evanston, Illinois 60208, United States
- Center for Engineering Sustainability and Resilience, Northwestern University, Evanston, Illinois 60208, United States
| |
Collapse
|
4
|
Vigués N, Pujol-Vila F, Macanás J, Muñoz M, Muñoz-Berbel X, Mas J. Fast fabrication of reusable polyethersulfone microbial biosensors through biocompatible phase separation. Talanta 2020; 206:120192. [PMID: 31514850 DOI: 10.1016/j.talanta.2019.120192] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/18/2019] [Accepted: 07/28/2019] [Indexed: 10/26/2022]
Abstract
In biosensors fabrication, entrapment in polymeric matrices allows efficient immobilization of the biorecognition elements without compromising their structure and activity. When considering living cells, the biocompatibility of both the matrix and the polymerization procedure are additional critical factors. Bio-polymeric gels (e.g. alginate) are biocompatible and polymerize under mild conditions, but they have poor stability. Most synthetic polymers (e.g. PVA), on the other hand, present improved stability at the expense of complex protocols involving chemical/physical treatments that decrease their biological compatibility. In an attempt to explore new solutions to this problem we have developed a procedure for the immobilization of bacterial cells in polyethersulfone (PES) using phase separation. The technology has been tested successfully in the construction of a bacterial biosensor for toxicity assessment. Biosensors were coated with a 300 μm bacteria-containing PES membrane, using non-solvent induced phase separation (membrane thickness ≈ 300 μm). With this method, up to 2.3 × 106 cells were immobilized in the electrode surface with an entrapment efficiency of 8.2%, without compromising cell integrity or viability. Biosensing was performed electrochemically through ferricyanide respirometry, with metabolically-active entrapped bacteria reducing ferricyanide in the presence of glucose. PES biosensors showed good stability and reusability during dry frozen storage for up to 1 month. The analytical performance of the sensors was assessed carrying out a toxicity assay in which 3,5-dichlorophenol (DCP) was used as a model toxic compound. The biosensor provided a concentration-dependent response to DCP with half-maximal effective concentration (EC50) of 9.2 ppm, well in agreement with reported values. This entrapment methodology is susceptible of mass production and allows easy and repetitive production of robust and sensitive bacterial biosensors.
Collapse
Affiliation(s)
- N Vigués
- Department of Genetics and Microbiology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Barcelona, Spain.
| | - F Pujol-Vila
- Department of Genetics and Microbiology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Barcelona, Spain
| | - J Macanás
- Department of Chemical Engineering, Universitat Politècnica de Catalunya, Spain
| | - M Muñoz
- Department of Chemistry, Universitat Autònoma de Barcelona, UAB, Spain
| | - X Muñoz-Berbel
- Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Bellaterra, Barcelona, Spain
| | - J Mas
- Department of Genetics and Microbiology, Universitat Autònoma de Barcelona (UAB), Bellaterra, Barcelona, Spain
| |
Collapse
|
5
|
New methodologies in screening of antibiotic residues in animal-derived foods: Biosensors. Talanta 2017; 175:435-442. [PMID: 28842013 DOI: 10.1016/j.talanta.2017.07.044] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2017] [Revised: 05/15/2017] [Accepted: 07/13/2017] [Indexed: 01/05/2023]
Abstract
Antibiotics are leading medicine asset for fighting against microbial infection, but also one of the important causes of death worldwide. Many antibiotics used as therapeutics and growth promotion agents in animals can lead to antibiotic residues in animal-derived food which harm the health of people. Hence, it is vital to screen antibiotic residues in animal derived foods. Typical methods for screening antibiotic residues are based on microbiological growth inhibition and immunological analyses. However these two methods have some disadvantages, such as poor sensitive, lack of specificity and etc. Therefore, it is necessary to develop simple, more efficient and high sensitive screening methods of antibiotic residues. These assays have been introduced for the screening of numerous food samples. Biosensors are emerging methods, applied in screening antibiotic residues in animal-derived foods. Two types of biosensors, whole-cell based biosensors and surface plasmon resonance-based sensors have been extensively used. Their advantages include portability, small sample requirement, high sensitivity and good specificity over the traditional screening methods.
Collapse
|
6
|
Abstract
There is a growing need to enhance our capabilities in medical and environmental diagnostics. Synthetic biologists have begun to focus their biomolecular engineering approaches toward this goal, offering promising results that could lead to the development of new classes of inexpensive, rapidly deployable diagnostics. Many conventional diagnostics rely on antibody-based platforms that, although exquisitely sensitive, are slow and costly to generate and cannot readily confront rapidly emerging pathogens or be applied to orphan diseases. Synthetic biology, with its rational and short design-to-production cycles, has the potential to overcome many of these limitations. Synthetic biology devices, such as engineered gene circuits, bring new capabilities to molecular diagnostics, expanding the molecular detection palette, creating dynamic sensors, and untethering reactions from laboratory equipment. The field is also beginning to move toward in vivo diagnostics, which could provide near real-time surveillance of multiple pathological conditions. Here, we describe current efforts in synthetic biology, focusing on the translation of promising technologies into pragmatic diagnostic tools and platforms.
Collapse
|
7
|
|
8
|
Jouanneau S, Durand MJ, Lahmar A, Thouand G. Main Technological Advancements in Bacterial Bioluminescent Biosensors Over the Last Two Decades. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2015:101-116. [PMID: 26475467 DOI: 10.1007/10_2015_333] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Environmental quality assessment is an extensive field of research due to the permanent increase of the stringency imposed by the legislative framework. To complete the wide panel of measurement methods, essentially based on physicochemical tools, some scientists focused on the development of alternative biological methods such as those based on the use of bioluminescent bacteria biosensors. The first report dedicated to the development of such biosensors dates back to 1967 and describes an analytical system designed to address the problem of air toxicity assessment. Nevertheless the available technologies in the photosensitive sensors field were not mature enough and, as a result, limited biosensor development possibilities. For about 20 years, the wide democratisation of photosensors coupled with advances in the genetic engineering field have allowed the expansion of the scope of possibilities of bioluminescent bacterial biosensors, allowing a significant emergence of these biotechnologies. This chapter retraces the history of the main technological evolutions that bacterial bioluminescent biosensors have known over the last two decades. Graphical Abstract.
Collapse
Affiliation(s)
- S Jouanneau
- University of Nantes, UMR CNRS GEPEA 6144, 18 Bd Gaston Defferre, Nantes, 85000, La Roche sur Yon, France.
| | - M J Durand
- University of Nantes, UMR CNRS GEPEA 6144, 18 Bd Gaston Defferre, Nantes, 85000, La Roche sur Yon, France
| | - A Lahmar
- University of Nantes, UMR CNRS GEPEA 6144, 18 Bd Gaston Defferre, Nantes, 85000, La Roche sur Yon, France
| | - G Thouand
- University of Nantes, UMR CNRS GEPEA 6144, 18 Bd Gaston Defferre, Nantes, 85000, La Roche sur Yon, France
| |
Collapse
|
9
|
Jia K, Ionescu RE. Measurement of Bacterial Bioluminescence Intensity and Spectrum: Current Physical Techniques and Principles. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2015; 154:19-45. [PMID: 25981856 DOI: 10.1007/10_2015_324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/22/2023]
Abstract
: Bioluminescence is light production by living organisms, which can be observed in numerous marine creatures and some terrestrial invertebrates. More specifically, bacterial bioluminescence is the "cold light" produced and emitted by bacterial cells, including both wild-type luminescent and genetically engineered bacteria. Because of the lively interplay of synthetic biology, microbiology, toxicology, and biophysics, different configurations of whole-cell biosensors based on bacterial bioluminescence have been designed and are widely used in different fields, such as ecotoxicology, food toxicity, and environmental pollution. This chapter first discusses the background of the bioluminescence phenomenon in terms of optical spectrum. Platforms for bacterial bioluminescence detection using various techniques are then introduced, such as a photomultiplier tube, charge-coupled device (CCD) camera, micro-electro-mechanical systems (MEMS), and complementary metal-oxide-semiconductor (CMOS) based integrated circuit. Furthermore, some typical biochemical methods to optimize the analytical performances of bacterial bioluminescent biosensors/assays are reviewed, followed by a presentation of author's recent work concerning the improved sensitivity of a bioluminescent assay for pesticides. Finally, bacterial bioluminescence as implemented in eukaryotic cells, bioluminescent imaging, and cancer cell therapies is discussed.
Collapse
Affiliation(s)
- Kun Jia
- Laboratoire de Nanotechnologie et d'Instrumentation Optique, Institut Charles Delaunay, Université de Technologie de Troyes, UMR CNRS 6281, 12 rue Marie Curie CS 42060, TROYES, 10004 Cedex, France
| | - Rodica Elena Ionescu
- Laboratoire de Nanotechnologie et d'Instrumentation Optique, Institut Charles Delaunay, Université de Technologie de Troyes, UMR CNRS 6281, 12 rue Marie Curie CS 42060, TROYES, 10004 Cedex, France.
| |
Collapse
|
10
|
Tsai HF, Tsai YC, Yagur-Kroll S, Palevsky N, Belkin S, Cheng JY. Water pollutant monitoring by a whole cell array through lens-free detection on CCD. LAB ON A CHIP 2015; 15:1472-1480. [PMID: 25608666 DOI: 10.1039/c4lc01189a] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Environmental contamination has become a serious problem to human and environmental health, as exposure to a wide range of possible contaminants continuously increases due to industrial and agricultural activities. Whole cell sensors have been proposed as a powerful tool to detect class-specific toxicants based upon their biological activity and bioavailability. We demonstrated a robust toxicant detection platform based on a bioluminescence whole cell sensor array biochip (LumiChip). LumiChip harbors an integrated temperature control and a 16-member sensor array, as well as a simple but highly efficient luminescence collection setup. On LumiChip, samples were infused in an oxygen-permeable microfluidic flow channel to reach the sensor array. Time-lapse changes in bioluminescence emitted by the array members were measured on a single window-removed linear charge-coupled device (CCD) commonly used in commercial industrial process control or in barcode readers. Removal of the protective window on the linear CCD allowed lens-free direct interfacing of LumiChip to the CCD surface for measurement with high light collection efficiency. Bioluminescence induced by simulated contamination events was detected within 15 to 45 minutes. The portable LumiSense system utilizing the linear CCD in combination with the miniaturized LumiChip is a promising potential platform for on-site environmental monitoring of toxicant contamination.
Collapse
Affiliation(s)
- Hsieh-Fu Tsai
- Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan.
| | | | | | | | | | | |
Collapse
|
11
|
Cho JH, Lee DY, Lim WK, Shin HJ. A RECOMBINANTEscherichia coliBIOSENSOR FOR DETECTING POLYCYCLIC AROMATIC HYDROCARBONS IN GAS AND AQUEOUS PHASES. Prep Biochem Biotechnol 2014; 44:849-60. [DOI: 10.1080/10826068.2014.887577] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
12
|
Chan AC, Ager D, Thompson IP. Resolving the mechanism of bacterial inhibition by plant secondary metabolites employing a combination of whole-cell biosensors. J Microbiol Methods 2013; 93:209-17. [PMID: 23566822 DOI: 10.1016/j.mimet.2013.03.021] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2013] [Revised: 03/26/2013] [Accepted: 03/26/2013] [Indexed: 11/30/2022]
Abstract
Tightening regulations regarding the use of biocides have stimulated interest in investigating alternatives to current antimicrobial strategies. Plant essential oils and their constituent compounds are promising candidates as novel antimicrobial agents because of their excellent ability in killing microbes while being non-toxic to humans at antimicrobially-active concentrations. Allyl isothiocyanate (AIT), carvacrol, cinnamaldehyde (CNAD), citral, and thymol were investigated for their antibacterial activity against Bacillus subtilis, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. The five compounds were screened via disc diffusion assay and broth microdilution method, by which inhibition zone diameters, minimum inhibitory concentrations (MICs), and minimum bactericidal concentrations (MBCs) were determined. AIT and CNAD displayed the greatest inhibitory effects against all species tested, with AIT yielding MICs of 156.25mg/L and MBCs of 156.25 to 312.5mg/L, and CNAD yielding MICs of 78.125 to 156.25mg/L and MBCs of 78.125 to 312.5mg/L. Based on these results, AIT and CNAD were selected for closer examination of their toxic effects. Two complementary bioluminescence-based bacterial biosensors, E. coli HB101_pUCD607_lux and Acinetobacter baylyi ADP1_recA_lux, were employed to examine the dose-response relationships and mechanism of action of AIT and CNAD. This is the first reported study to employ a lux-based biosensor assay coupled with parallel plate count experiments to demonstrate that AIT and CNAD not only damaged cell membranes, but also disrupted cellular metabolism and energy production in bacteria. It is also the first to use genotoxicity-sensing whole-cell bioreporters to demonstrate that neither AIT nor CNAD induced expression of the universal DNA repair gene, recA. This suggests that AIT and CNAD were not genotoxic. As an antimicrobial agent, it is advantageous that the compound be genetically non-damaging so that toxicity towards higher multicellular organisms and resistance development can be minimized. Thus, AIT and CNAD may be of high value as novel antimicrobial agents.
Collapse
Affiliation(s)
- Andrea C Chan
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK.
| | | | | |
Collapse
|
13
|
Walawalkar YD, Phadke R, Noronha S, Patankar S, Pillai B. Engineering whole-cell biosensors to evaluate the effect of osmotic conditions on bacteria. ANN MICROBIOL 2012. [DOI: 10.1007/s13213-012-0587-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
14
|
Narsaiah K, Jha SN, Bhardwaj R, Sharma R, Kumar R. Optical biosensors for food quality and safety assurance-a review. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY 2012; 49:383-406. [PMID: 23904648 PMCID: PMC3550887 DOI: 10.1007/s13197-011-0437-6] [Citation(s) in RCA: 116] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 06/08/2011] [Accepted: 06/14/2011] [Indexed: 01/18/2023]
Abstract
Food quality and safety is a scientific discipline describing handling, preparation and storage of food in ways that prevent food borne illness. Food serves as a growth medium for microorganisms that can be pathogenic or cause food spoilage. Therefore, it is imperative to have stringent laws and standards for the preparation, packaging and transportation of food. The conventional methods for detection of food contamination based on culturing, colony counting, chromatography and immunoassay are tedious and time consuming while biosensors have overcome some of these disadvantages. There is growing interest in biosensors due to high specificity, convenience and quick response. Optical biosensors show greater potential for the detection of pathogens, pesticide and drug residues, hygiene monitoring, heavy metals and other toxic substances in the food to check whether it is safe for consumption or not. This review focuses on optical biosensors, the recent developments in the associated instrumentation with emphasis on fiber optic and surface plasmon resonance (SPR) based biosensors for detecting a range of analytes in food samples, the major advantages and challenges associated with optical biosensors. It also briefly covers the different methods employed for the immobilization of bio-molecules used in developing biosensors.
Collapse
Affiliation(s)
- K. Narsaiah
- Agricultural Structures and Environmental Control Division, Central Institute of Post-harvest Engineering and Technology, Ludhiana, 141004 India
| | - Shyam Narayan Jha
- Agricultural Structures and Environmental Control Division, Central Institute of Post-harvest Engineering and Technology, Ludhiana, 141004 India
| | - Rishi Bhardwaj
- Agricultural Structures and Environmental Control Division, Central Institute of Post-harvest Engineering and Technology, Ludhiana, 141004 India
| | - Rajiv Sharma
- Agricultural Structures and Environmental Control Division, Central Institute of Post-harvest Engineering and Technology, Ludhiana, 141004 India
| | - Ramesh Kumar
- Agricultural Structures and Environmental Control Division, Central Institute of Post-harvest Engineering and Technology, Ludhiana, 141004 India
| |
Collapse
|
15
|
Adiguzel Y, Kulah H. CMOS cell sensors for point-of-care diagnostics. SENSORS (BASEL, SWITZERLAND) 2012; 12:10042-66. [PMID: 23112587 PMCID: PMC3472815 DOI: 10.3390/s120810042] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2012] [Revised: 07/06/2012] [Accepted: 07/21/2012] [Indexed: 12/12/2022]
Abstract
The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies.
Collapse
Affiliation(s)
- Yekbun Adiguzel
- METU-MEMS Research and Application Center, Middle East Technical University, Ankara 06800, Turkey
| | - Haluk Kulah
- METU-MEMS Research and Application Center, Middle East Technical University, Ankara 06800, Turkey
- Department of Electrical and Electronics Engineering, Middle East Technical University, Ankara 06800, Turkey; E-Mail:
| |
Collapse
|
16
|
Pseudomonas fluorescens HK44: lessons learned from a model whole-cell bioreporter with a broad application history. SENSORS 2012; 12:1544-71. [PMID: 22438725 PMCID: PMC3304127 DOI: 10.3390/s120201544] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2011] [Revised: 01/24/2012] [Accepted: 02/03/2012] [Indexed: 11/21/2022]
Abstract
Initially described in 1990, Pseudomonas fluorescens HK44 served as the first whole-cell bioreporter genetically endowed with a bioluminescent (luxCDABE) phenotype directly linked to a catabolic (naphthalene degradative) pathway. HK44 was the first genetically engineered microorganism to be released in the field to monitor bioremediation potential. Subsequent to that release, strain HK44 had been introduced into other solids (soils, sands), liquid (water, wastewater), and volatile environments. In these matrices, it has functioned as one of the best characterized chemically-responsive environmental bioreporters and as a model organism for understanding bacterial colonization and transport, cell immobilization strategies, and the kinetics of cellular bioluminescent emission. This review summarizes the characteristics of P. fluorescens HK44 and the extensive range of its applications with special focus on the monitoring of bioremediation processes and biosensing of environmental pollution.
Collapse
|
17
|
The evolution of the bacterial luciferase gene cassette (lux) as a real-time bioreporter. SENSORS 2012; 12:732-52. [PMID: 22368493 PMCID: PMC3279237 DOI: 10.3390/s120100732] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/26/2011] [Revised: 12/30/2011] [Accepted: 01/09/2012] [Indexed: 01/23/2023]
Abstract
The bacterial luciferase gene cassette (lux) is unique among bioluminescent bioreporter systems due to its ability to synthesize and/or scavenge all of the substrate compounds required for its production of light. As a result, the lux system has the unique ability to autonomously produce a luminescent signal, either continuously or in response to the presence of a specific trigger, across a wide array of organismal hosts. While originally employed extensively as a bacterial bioreporter system for the detection of specific chemical signals in environmental samples, the use of lux as a bioreporter technology has continuously expanded over the last 30 years to include expression in eukaryotic cells such as Saccharomyces cerevisiae and even human cell lines as well. Under these conditions, the lux system has been developed for use as a biomedical detection tool for toxicity screening and visualization of tumors in small animal models. As the technologies for lux signal detection continue to improve, it is poised to become one of the first fully implantable detection systems for intra-organismal optical detection through direct marriage to an implantable photon-detecting digital chip. This review presents the basic biochemical background that allows the lux system to continuously autobioluminesce and highlights the important milestones in the use of lux-based bioreporters as they have evolved from chemical detection platforms in prokaryotic bacteria to rodent-based tumorigenesis study targets. In addition, the future of lux imaging using integrated circuit microluminometry to image directly within a living host in real-time will be introduced and its role in the development of dose/response therapeutic systems will be highlighted.
Collapse
|
18
|
Karig DK, Iyer S, Simpson ML, Doktycz MJ. Expression optimization and synthetic gene networks in cell-free systems. Nucleic Acids Res 2011; 40:3763-74. [PMID: 22180537 PMCID: PMC3333853 DOI: 10.1093/nar/gkr1191] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Synthetic biology offers great promise to a variety of applications through the forward engineering of biological function. Most efforts in this field have focused on employing living cells, yet cell-free approaches offer simpler and more flexible contexts. Here, we evaluate cell-free regulatory systems based on T7 promoter-driven expression by characterizing variants of TetR and LacI repressible T7 promoters in a cell-free context and examining sequence elements that determine expression efficiency. Using the resulting constructs, we then explore different approaches for composing regulatory systems, leading to the implementation of inducible negative feedback in Escherichia coli extracts and in the minimal PURE system, which consists of purified proteins necessary for transcription and translation. Despite the fact that negative feedback motifs are common and essential to many natural and engineered systems, this simple building block has not previously been implemented in a cell-free context. As a final step, we then demonstrate that the feedback systems developed using our cell-free approach can be implemented in live E. coli as well, illustrating the potential for using cell-free expression to fast track the development of live cell systems in synthetic biology. Our quantitative cell-free component characterizations and demonstration of negative feedback embody important steps on the path to harnessing biological function in a bottom-up fashion.
Collapse
Affiliation(s)
- David K Karig
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Bethel Valley Road, Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA.
| | | | | | | |
Collapse
|
19
|
Ahn JM, Kim JH, Kim JH, Gu MB. Randomly distributed arrays of optically coded functional microbeads for toxicity screening and monitoring. LAB ON A CHIP 2010; 10:2695-2701. [PMID: 20664847 DOI: 10.1039/c004942e] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We have successfully developed optically coded functional microbeads by co-encapsulating both bioluminescent reporter bacterial cells and fluorescent microspheres within a common alginate microbead. These microbeads harboring an individual self-identification code using fluorescent microspheres could be randomly scattered on any multi-well chip plate as long as the size of the microbeads are made to fit on it with the result that, since cell types are identified on the basis of fluorescent color, microbead arrays were fabricated without pre-designation of an individual well. As an example of this method, five different stress specific bioluminescent bacterial strains, each with a different optical code, were successfully implemented to make five different types of optically coded functional microbeads, with a speed of about 30 microbeads/min. Each functional microbead has a specific stress-specific bacterial strain and, as an identification optical code, one of five optical codes generated from fluorescence microspheres such as yellow, green, red, yellow + green, or no fluorescence. This final randomly scattered functional microbeads array biochip, with a fast fabrication of each chip at every 2 min, successfully demonstrated its ability in toxicity screening and monitoring for samples with a few examples for five different stress chemicals. This simple and fast, but not tedious and complicated procedure should be widely and practically used in making cell array chips for the monitoring of environmental toxicity, new-borne chemicals, pharmaceutical drugs and cosmic rays in the space station or spaceships in future.
Collapse
Affiliation(s)
- Joo-Myung Ahn
- School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul, 136-701, Republic of Korea
| | | | | | | |
Collapse
|
20
|
Where microbiology meets microengineering: design and applications of reporter bacteria. Nat Rev Microbiol 2010; 8:511-22. [DOI: 10.1038/nrmicro2392] [Citation(s) in RCA: 404] [Impact Index Per Article: 28.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
Liu X, Germaine KJ, Ryan D, Dowling DN. Whole-cell fluorescent biosensors for bioavailability and biodegradation of polychlorinated biphenyls. SENSORS 2010; 10:1377-98. [PMID: 22205873 PMCID: PMC3244019 DOI: 10.3390/s100201377] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2009] [Revised: 01/14/2010] [Accepted: 01/29/2010] [Indexed: 11/30/2022]
Abstract
Whole-cell microbial biosensors are one of the newest molecular tools used in environmental monitoring. Such biosensors are constructed through fusing a reporter gene such as lux, gfp or lacZ, to a responsive promoter. There have been many reports of the applications of biosensors, particularly their use in assaying pollutant toxicity and bioavailability. This paper reviews the basic concepts behind the construction of whole-cell microbial biosensors for pollutant monitoring, and describes the applications of two such biosensors for detecting the bioavailability and biodegradation of Polychlorinated Biphenyls (PCBs).
Collapse
Affiliation(s)
- Xuemei Liu
- Department of Science and Health, Institute of Technology Carlow, Kilkenny Road, Carlow, Ireland.
| | | | | | | |
Collapse
|
22
|
Martineau R, Stout V, Towe B. Whole cell biosensing via recA::mCherry and LED-based flow-through fluorometry. Biosens Bioelectron 2009; 25:759-66. [DOI: 10.1016/j.bios.2009.08.042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2009] [Revised: 08/14/2009] [Accepted: 08/15/2009] [Indexed: 10/20/2022]
|
23
|
Wireless endoscopy: technology and design. Methods Mol Biol 2009. [PMID: 19763467 DOI: 10.1007/978-1-60327-106-6_10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
In this chapter we review the current capsule technology and the more conventional "gold standard" technologies against which the wireless devices are compared. Over the years there have been several implementations of capsule devices of growing sophistication as new technology has become available. A notable feature is the extent to which the devices available at any given time have relied upon other more mainstream technologies from which capsule builders have been able to borrow. As an inevitable consequence, device complexity and functionality have increased.
Collapse
|
24
|
Ben-Yoav H, Elad T, Shlomovits O, Belkin S, Shacham-Diamand Y. Optical modeling of bioluminescence in whole cell biosensors. Biosens Bioelectron 2009; 24:1969-73. [DOI: 10.1016/j.bios.2008.10.035] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2008] [Revised: 10/02/2008] [Accepted: 10/06/2008] [Indexed: 11/30/2022]
|
25
|
Detecting AhR ligands in sediments using bioluminescent reporter yeast. Biosens Bioelectron 2008; 23:1850-5. [DOI: 10.1016/j.bios.2008.02.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2007] [Revised: 02/27/2008] [Accepted: 02/28/2008] [Indexed: 11/24/2022]
|
26
|
Elman NM, Ben-Yoav H, Sternheim M, Rosen R, Krylov S, Shacham-Diamand Y. Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors. Biosens Bioelectron 2008; 23:1631-6. [DOI: 10.1016/j.bios.2008.01.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2007] [Revised: 01/09/2008] [Accepted: 01/29/2008] [Indexed: 12/01/2022]
|
27
|
Field methods in the study of toxic cyanobacterial blooms: results and insights from Lake Erie Research. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2008; 619:501-12. [DOI: 10.1007/978-0-387-75865-7_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
28
|
Mota M, Yelshin A, Fidaleo M, Flickinger MC. Modelling diffusivity in porous polymeric membranes with an intermediate layer containing microbial cells. Biochem Eng J 2007. [DOI: 10.1016/j.bej.2007.05.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
29
|
Ron EZ. Biosensing environmental pollution. Curr Opin Biotechnol 2007; 18:252-6. [PMID: 17532203 DOI: 10.1016/j.copbio.2007.05.005] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2007] [Revised: 04/09/2007] [Accepted: 05/11/2007] [Indexed: 11/18/2022]
Abstract
Whole-cell biosensors are finding increasing use for the detection of environmental pollution and toxicity. These biosensors are constructed through the fusion of promoters, responsive to the relevant environmental conditions, to easily monitored reporter genes. Depending on the choice of reporter gene, expression can be monitored by the production of colour, light, fluorescence or electrochemical reactions. Recent advances in this area have included the development of biosensors of compact size that enable the on-line and in situ monitoring of a large number of environmental parameters.
Collapse
Affiliation(s)
- Eliora Z Ron
- Department of Molecular Microbiology and Biotechnology, Tel Aviv University, Tel Aviv 69978, Israel.
| |
Collapse
|
30
|
|
31
|
Islam SK, Vijayaraghavan R, Zhang M, Ripp S, Caylor SD, Weathers B, Moser S, Terry S, Blalock BJ, Sayler GS. Integrated Circuit Biosensors Using Living Whole-Cell Bioreporters. ACTA ACUST UNITED AC 2007. [DOI: 10.1109/tcsi.2006.887982] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
32
|
Live bacterial cells as analytical tools for speciation analysis: Hypothetical or practical? Trends Analyt Chem 2006. [DOI: 10.1016/j.trac.2006.03.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
33
|
Paitan Y, Biran I, Shechter N, Biran D, Rishpon J, Ron EZ. Monitoring aromatic hydrocarbons by whole cell electrochemical biosensors. Anal Biochem 2005; 335:175-83. [PMID: 15556555 DOI: 10.1016/j.ab.2004.08.032] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2004] [Indexed: 10/26/2022]
Abstract
In this article, we describe a bacterial whole cell electrochemical biosensors system that can be used for monitoring aromatic hydrocarbons. These bacterial biosensors are based on fusions of a promoter that is sensitive to aromatic compounds (the promoter region of the xylS gene and the xylR gene coding for the transcriptional regulator of the xyl operon) to reporter genes that can be monitored electrochemically at real-time and on-line. The xylS promoter was fused upstream of two promoterless genes coding the lacZ gene and phoA. These constructs reacted specifically to aromatic compounds but not to nonaromatic compounds, and we could detect, within minutes, micromolar concentrations of different aromatic hydrocarbons such as xylene and toluene. The use of two different reporter genes allows the future construction of a multianalyte detection system for simultaneous monitoring of several pollutants. These whole cell biosensors are potentially useful for on-line and in situ detection of aromatic compounds and as early warning systems of environmental hazards.
Collapse
Affiliation(s)
- Yossi Paitan
- Department of Molecular Microbiology and Biotechnology, George S. Wise Faculty of Life Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | | | | | | | | | | |
Collapse
|
34
|
Shin HJ, Park HH, Lim WK. Freeze-dried recombinant bacteria for on-site detection of phenolic compounds by color change. J Biotechnol 2005; 119:36-43. [PMID: 16051389 DOI: 10.1016/j.jbiotec.2005.06.002] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2004] [Revised: 05/24/2005] [Accepted: 06/01/2005] [Indexed: 11/16/2022]
Abstract
We herein report the development of a recombinant bacterial biosensor for the rapid and easy detection of phenolic compounds in the field. A plasmid was designed to encode a beta-galactosidase reporter gene under the control of capR, an activator involved in phenolic compound degradation. The construct was transformed into Escherichia coli, and transformed cells were stored after being freeze-dried in the presence of sucrose. For detection of phenolic compounds, the cells were rehydrated, and used instantly, without any growth step. In the presence of 0.1 microM-10mM phenol, we observed a red color from hydrolysis of chlorophenol red beta-D-galactopyranoside (CPRG) or an indigo color from hydrolysis of X-galactopyranoside (X-gal). Other phenolic compounds could be detected by this system, including catechol, 2-methylphenol, 2-chlorophenol, 3-methylphenol, 2-nitrophenol, and 4-chlorophenol. These results suggest that this novel bacteria biosensor may be useful for easy, on-site detection of phenolic compounds without the need for unwieldy equipment or sample pretreatment. Indeed, biosensor systems involving beta-galactosidase-expressing freeze-dried recombinant bacteria could prove useful for the in situ detection of many more compounds in the future.
Collapse
Affiliation(s)
- Hae Ja Shin
- Environmental Engineering Major, Division of Applied Bioengineering, Dongseo University, Busan 617-716, Republic of Korea.
| | | | | |
Collapse
|
35
|
Kim MN, Park HH, Lim WK, Shin HJ. Construction and comparison of Escherichia coli whole-cell biosensors capable of detecting aromatic compounds. J Microbiol Methods 2005; 60:235-45. [PMID: 15590098 DOI: 10.1016/j.mimet.2004.09.018] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2004] [Revised: 08/31/2004] [Accepted: 09/28/2004] [Indexed: 11/28/2022]
Abstract
The XylR regulatory protein is a transcription factor involved in the BTEX (benzene, toluene, ethylbenzene, and xylene) degradation pathway in Pseudomonas species. When XylR-dependent stimulation of transcription from a plasmid containing XylR and its cognate promoters Pr and Pu was monitored as firefly luciferase activities in Escherichia coli, a notably high level of basal activity was observed in the absence of inducers. To improve the response specificity of XylR in this system, two related but different promoters were tested for their activities; the XylS activator promoter Ps and the DmpR activator promoter Po. Po with the deletion of its own upstream activating sequences (UASs; Po') showed a very low level of basal activity compared to Pu and Ps. The maximum level with the addition of inducers was increased 3151-fold by o-xylene with Po', while it was 31.5 and 74.1 fold by m-xylene with Pu and Ps, respectively. Gel mobility shift assay showed that the purified XylR without inducers can bind to Pr/Pu but not to Pr/Po', implying that XylR multimerization with Pr/Pu could be formed for initiation of transcription in this system. The data suggest that Po' can be an excellent alternative in constructing a signal-intensified, whole-cell biosensor in response to the xenobiotics.
Collapse
Affiliation(s)
- Mi Na Kim
- Department of Molecular Biology, College of Natural Sciences, Pusan National University, Busan 609-735, Republic of Korea
| | | | | | | |
Collapse
|
36
|
Koutsopoulos S, Tjeerdsma AM, Lieshout JFT, van der Oost J, Norde W. In Situ Structure and Activity Studies of an Enzyme Adsorbed on Spectroscopically Undetectable Particles. Biomacromolecules 2005; 6:1176-84. [PMID: 15877331 DOI: 10.1021/bm049471u] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The structural characteristics and the activity of a hyperthermophilic endoglucanase were investigated upon adsorption. Silica (hydrophilic) and Teflon (hydrophobic) surfaces were selected for the study. The materials were specially designed so that the interaction of the particles with light was negligible, and the enzyme conformation in the adsorbed state was monitored in situ. The adsorption isotherms were determined, and the adsorbed endoglucanase was studied using a number of spectroscopic techniques, enzymatic activity tests, and dynamic light scattering. Experiments were performed at pH values below, at, and above the isoelectric point of the enzyme. It was shown that the enzyme adsorbed on the hydrophobic surface of Teflon with higher affinity as compared to the hydrophilic silica nanoparticles. In all cases, adsorption was followed by (slight) changes in the secondary structure resulting in decreased beta-structural content. The changes were more profound upon adsorption on Teflon. The adsorbed enzyme remained active in the adsorbed state in spite of the structural changes induced when interacting with the surfaces.
Collapse
Affiliation(s)
- Sotirios Koutsopoulos
- Laboratory of Physical Chemistry and Colloid Science, Wageningen University, Dreijenplein 6, 6703 HB Wageningen, The Netherlands.
| | | | | | | | | |
Collapse
|
37
|
Abstract
The delicate and dynamic balance of the physiological steady state and its maintenance is well characterized by studies of bacterial stress response. Through the use of genetic analysis, numerous stress regulons, their physiological regulators and their biochemical processes have been delineated. In particular, transcriptionally activated stress regulons are subjects of study and application. These regulons include those that respond to macromolecular damage and toxicity as well as to nutrient starvation. The convenience of reporter gene fusions has allowed the creation of biosensor strains, resulting from the fusion of stress-responsive promoters with a variety of reporter genes. Such cellular biosensors are being used for monitoring dynamic systems and can report the presence of environmental stressors in real time. They provide a greater range of sensitivity, e.g. to sub-lethal concentrations of toxicants, than the simple assessment of cell viability. The underlying physiological context of the reporter strains results in the detection of bioavailable concentrations of both toxicants and nutrients. Culture conditions and host strain genotypes can be customized so as to maximize the sensitivity of the strain for a particular application. Collections of specific strains that are grouped in panels are used to diagnose targets or mode of action for unknown toxicants. Further application in massive by parallel DNA and gene fusion arrays greatly extends the information available for diagnosis of modes of action and may lead to development of novel high-throughput screens. Future studies will include more panels, arrays, as well as single reporter cell detection for a better understanding of the population heterogeneity during stress response. New knowledge of physiology gained from further studies of novel systems, or using innovative methods of analysis, will undoubtedly yield still more useful and informative environmental biosensors.
Collapse
Affiliation(s)
- Amy Cheng Vollmer
- Department of Biology, Swarthmore College, 500 College Avenue, Swarthmore, PA 19081, USA.
| | | |
Collapse
|
38
|
Abstract
Engineering bacteria for measuring chemicals of environmental or toxicological concern (bioreporter bacteria) has grown slowly into a mature research area. Despite many potential advantages, current bioreporters do not perform well enough to comply with environmental detection standards. Basically, the reasons for this are the lack of engineering principles in the detection chain in the bioreporters. Here, we dissect critical steps in the detection chain and illustrate how bioreporter design could be improved by mutagenizing specificity and selectivity of the sensing and regulatory proteins, by newer expression strategies and application of different signalling networks. Furthermore, we describe how redesigning bioreporter assays with respect to pollutant transport into the cells and application of other detection devices can decrease detection limits and increase the speed of detection.
Collapse
Affiliation(s)
- Jan Roelof van der Meer
- Department of Fundamental Microbiology, Bâtiment de Biologie, University of Lausanne, 1015 Lausanne, Switzerland.
| | | | | |
Collapse
|
39
|
Valdman E, Valdman B, Battaglini F, Leite S. On-line detection of low naphthalene concentrations with a bioluminescent sensor. Process Biochem 2004. [DOI: 10.1016/s0032-9592(03)00248-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
40
|
Werlen C, Jaspers MCM, van der Meer JR. Measurement of biologically available naphthalene in gas and aqueous phases by use of a Pseudomonas putida biosensor. Appl Environ Microbiol 2004; 70:43-51. [PMID: 14711624 PMCID: PMC321291 DOI: 10.1128/aem.70.1.43-51.2004] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 micro M). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices.
Collapse
Affiliation(s)
- Christoph Werlen
- Process of Environmental Microbiology and Molecular Ecotoxicology, Swiss Federal Institute for Environmental Science and Technology (EAWAG), CH 8600 Dübendorf, Switzerland
| | | | | |
Collapse
|
41
|
Nivens DE, McKnight TE, Moser SA, Osbourn SJ, Simpson ML, Sayler GS. Bioluminescent bioreporter integrated circuits: potentially small, rugged and inexpensive whole-cell biosensors for remote environmental monitoring. J Appl Microbiol 2004; 96:33-46. [PMID: 14678157 DOI: 10.1046/j.1365-2672.2003.02114.x] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- D E Nivens
- Center for Environmental Biotechnology, University of Tennessee, Knoxville, TN 37996, USA
| | | | | | | | | | | |
Collapse
|
42
|
Abstract
Recent advances in molecular biology have extended our understanding of the metabolic processes related to microbial transformation of petroleum hydrocarbons. The physiological responses of microorganisms to the presence of hydrocarbons, including cell surface alterations and adaptive mechanisms for uptake and efflux of these substrates, have been characterized. New molecular techniques have enhanced our ability to investigate the dynamics of microbial communities in petroleum-impacted ecosystems. By establishing conditions which maximize rates and extents of microbial growth, hydrocarbon access, and transformation, highly accelerated and bioreactor-based petroleum waste degradation processes have been implemented. Biofilters capable of removing and biodegrading volatile petroleum contaminants in air streams with short substrate-microbe contact times (<60 s) are being used effectively. Microbes are being injected into partially spent petroleum reservoirs to enhance oil recovery. However, these microbial processes have not exhibited consistent and effective performance, primarily because of our inability to control conditions in the subsurface environment. Microbes may be exploited to break stable oilfield emulsions to produce pipeline quality oil. There is interest in replacing physical oil desulfurization processes with biodesulfurization methods through promotion of selective sulfur removal without degradation of associated carbon moieties. However, since microbes require an environment containing some water, a two-phase oil-water system must be established to optimize contact between the microbes and the hydrocarbon, and such an emulsion is not easily created with viscous crude oil. This challenge may be circumvented by application of the technology to more refined gasoline and diesel substrates, where aqueous-hydrocarbon emulsions are more easily generated. Molecular approaches are being used to broaden the substrate specificity and increase the rates and extents of desulfurization. Bacterial processes are being commercialized for removal of H(2)S and sulfoxides from petrochemical waste streams. Microbes also have potential for use in removal of nitrogen from crude oil leading to reduced nitric oxide emissions provided that technical problems similar to those experienced in biodesulfurization can be solved. Enzymes are being exploited to produce added-value products from petroleum substrates, and bacterial biosensors are being used to analyze petroleum-contaminated environments.
Collapse
Affiliation(s)
- Jonathan D Van Hamme
- Department of Biological Sciences, The University College of the Cariboo, Kamloops, British Columbia V2C 5N3
| | | | | |
Collapse
|
43
|
Park SM, Park HH, Lim WK, Shin HJ. A new variant activator involved in the degradation of phenolic compounds from a strain of Pseudomonas putida. J Biotechnol 2003; 103:227-36. [PMID: 12890609 DOI: 10.1016/s0168-1656(03)00122-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A new variant type of regulatory activator and relevant promoters (designated capR, Pr and Po) involved in the metabolism of phenolic compounds were cloned from Pseudomonas putida KCTC1452 by using PCR. The deduced amino acid sequence of CapR revealed a difference in nine amino acids from the effector binding domain of DmpR. To measure effector specificity, plasmids were constructed in such a way that the expression of luc gene for firefly luciferase or lacZ for beta-galactosidase as a reporter was under the control of capR. When Escherichia coli transformed with the plasmids was exposed to phenol, dramatic increases in the activity of luciferase or beta-galactosidase were observed in a range of 0.01-1 mM. Among various phenolic compounds tested, other effective compounds included catechol, 2-methylphenol, 3-methylphenol, 4-methylphenol, 2-chlorophenol, 4-chlorophenol, 2-nitrophenol, resorcinol, and 2, 5-dimethylphenol. The results indicate that CapR has effector specificity different from other related activators, CatR and DmpR. Waste water and soil potentially containing phenolic compounds were also tested by this system and the results were compared with chemical and GC data. The present results indicate that the biosensor consisting of capR and the promoters may be utilized for the development of a phenolic compounds-specific biosensor in monitoring the environmental pollutant.
Collapse
Affiliation(s)
- Seun Mi Park
- Department of Molecular Biology, College of Natural Sciences, Pusan National University, Busan 609-735, South Korea
| | | | | | | |
Collapse
|
44
|
Abstract
A live cell array biosensor was fabricated by immobilizing bacterial cells on the face of an optical imaging fiber containing a high-density array of microwells. Each microwell accommodates a single bacterium that was genetically engineered to respond to a specific analyte. A genetically modified Escherichia coli strain, containing the lacZ reporter gene fused to the heavy metal-responsive gene promoter zntA, was used to fabricate a mercury biosensor. A plasmid carrying the gene coding for the enhanced cyan fluorescent protein (ECFP) was also introduced into this sensing strain to identify the cell locations in the array. Single cell lacZ expression was measured when the array was exposed to mercury and a response to 100nM Hg(2+) could be detected after a 1-h incubation time. The optical imaging fiber-based single bacterial cell array is a flexible and sensitive biosensor platform that can be used to monitor the expression of different reporter genes and accommodate a variety of sensing strains.
Collapse
Affiliation(s)
- Israel Biran
- The Max Tishler Laboratory for Organic Chemistry, Department of Chemistry, Tufts University, Medford, MA 02155, USA
| | | | | | | |
Collapse
|
45
|
Rhodius V, Van Dyk TK, Gross C, LaRossa RA. Impact of genomic technologies on studies of bacterial gene expression. Annu Rev Microbiol 2003; 56:599-624. [PMID: 12142487 DOI: 10.1146/annurev.micro.56.012302.160925] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The ability to simultaneously monitor expression of all genes in any bacterium whose genome has been sequenced has only recently become available. This requires not only careful experimentation but also that voluminous data be organized and interpreted. Here we review the emerging technologies that are impacting the study of bacterial global regulatory mechanisms with a view toward discussing both perceived best practices and the current state of the art. To do this, we concentrate upon examples using Escherichia coli and Bacillus subtilis because prior work in these organisms provides a sound basis for comparison.
Collapse
Affiliation(s)
- Virgil Rhodius
- Department of Stomatology, University of California, San Francisco, 94143, USA.
| | | | | | | |
Collapse
|
46
|
Bioreporter pseudomonas fluorescens HK44 immobilized in a silica matrix. HEMIJSKA INDUSTRIJA 2003. [DOI: 10.2298/hemind0312596t] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The bioluminescent bioreporter Pseudomonas fluorescens HK44, the whole cell bacterial biosensor that responds to naphthalene and its metabolites via the production of visible light, was immobilized into a silica matrix by the sol-gel technique. The bioluminescence intensities were measured in the maximum of the bioluminescence band at X = 500 nm. The immobilized cells (>105 cells per g silica matrix) produced light after induction by salicylate (cone. > 10 g/l), naphthalene and aminobenzoic acid. The bioluminescence intensities induced by 2,3-dihydroxynaphthalene 3-hydroxybenzoic acid and 4-hydroxybenzoic acid were comparable to a negative control. The cells in the silica layers on glass slides produced light in response to the presence of an inductor at least 8 months after immobilization, and >50 induction cycles. The results showed that these test slides could be used as assays for the multiple determination of water pollution.
Collapse
|
47
|
Characterization of agarose as immobilization matrix model for a microbial biosensor. HEMIJSKA INDUSTRIJA 2003. [DOI: 10.2298/hemind0312600p] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Microbial biosensors are promising tools for the detection of specific substances in different fields, such as environmental, biomedical, food or agricultural. They allow rapid measurements, no need for complex sample preparation or specialized personnel and easy handling. In order to enhance the managing, miniaturization and stability of the biosensor and to prevent cell leaching, bacteria immobilization is desirable. A systematic characterization procedure to choose a suitable immobilization method and matrix, was proposed in this study. Physical properties, storage stability mass transport phenomena and biocompatibility were evaluated, employing agarose as the model matrix. Preliminary essays with bioluminescent bacteria detecting Tributyltin were also carried out.
Collapse
|
48
|
Bolton EK, Sayler GS, Nivens DE, Rochelle JM, Ripp S, Simpson ML. Integrated CMOS photodetectors and signal processing for very low-level chemical sensing with the bioluminescent bioreporter integrated circuit. SENSORS AND ACTUATORS. B, CHEMICAL 2002; 85:179-185. [PMID: 12238524 DOI: 10.1016/s0925-4005(02)00106-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We report an integrated CMOS microluminometer optimized for the detection of low-level bioluminescence as part of the bioluminescent bioreporter integrated circuit (BBIC). This microluminometer improves on previous devices through careful management of the sub-femtoampere currents, both signal and leakage, that flow in the front-end processing circuitry. In particular, the photodiode is operated with a reverse bias of only a few mV, requiring special attention to the reset circuitry of the current-to-frequency converter (CFC) that forms the front-end circuit. We report a sub-femtoampere leakage current and a minimum detectable signal (MDS) of 0.15 fA (1510 s integration time) using a room temperature 1.47 mm2 CMOS photodiode. This microluminometer can detect luminescence from as few as 5000 fully induced Pseudomonas fluorescens 5RL bacterial cells.
Collapse
Affiliation(s)
- Eric K Bolton
- Department of Electrical and Computer Engineering, University of Tennessee, Knoxville, TN 37916, USA
| | | | | | | | | | | |
Collapse
|
49
|
Stiner L, Halverson LJ. Development and characterization of a green fluorescent protein-based bacterial biosensor for bioavailable toluene and related compounds. Appl Environ Microbiol 2002; 68:1962-71. [PMID: 11916719 PMCID: PMC123894 DOI: 10.1128/aem.68.4.1962-1971.2002] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
A green fluorescent protein-based Pseudomonas fluorescens strain A506 biosensor was constructed and characterized for its potential to measure benzene, toluene, ethylbenzene, and related compounds in aqueous solutions. The biosensor is based on a plasmid carrying the toluene-benzene utilization (tbu) pathway transcriptional activator TbuT from Ralstonia pickettii PKO1 and a transcriptional fusion of its promoter PtbuA1 with a promoterless gfp gene on a broad-host-range promoter probe vector. TbuT was not limiting, since it was constitutively expressed by being fused to the neomycin phosphotransferase (nptII) promoter. The biosensor cells were readily induced, and fluorescence emission after induction periods of 3 h correlated well with toluene, benzene, ethylbenzene, and trichloroethylene concentrations. Our experiments using flow cytometry show that intermediate levels of gfp expression in response to toluene reflect uniform induction of cells. As the toluene concentration increases, the level of gfp expression per cell increases until saturation kinetics of the TbuT-PtbuA1 system are observed. Each inducer had a unique minimum concentration that was necessary for induction, with K(app) values that ranged from 3.3 +/- 1.8 microM for toluene to 35.6 +/- 16.6 microM for trichloroethylene (means +/- standard errors of the means), and maximal fluorescence response. The fluorescence response was specific for alkyl-substituted benzene derivatives and branched alkenes (di- and trichloroethylene, 2-methyl-2-butene). The biosensor responded in an additive fashion to the presence of multiple inducers and was unaffected by the presence of compounds that were not inducers, such as those present in gasoline. Flow cytometry revealed that, in response to toxic concentrations of gasoline, there was a small uninduced population and another larger fully induced population whose levels of fluorescence corresponded to the amount of effectors present in the sample. These results demonstrate the potential for green fluorescent protein-based bacterial biosensors to measure environmental contaminants.
Collapse
Affiliation(s)
- Lawrence Stiner
- Department of Microbiology, Iowa State University, Ames, Iowa 50011-1010, USA
| | | |
Collapse
|
50
|
Abstract
There is a continuing need for monitoring the health of the environment due to the presence of pollutants. Here, we review the development and attributes of biosensors by which bacteria have been genetically modified to express the luminescence genes, i.e. to glow, in a quantified manner, in response to pollutants. We have concentrated on the detection of organic hydrocarbon pollutants and discussed the molecular mechanisms by which some of these chemicals act as effector molecules on the respective regulatory systems. The future of environmental biosensors is predictably bright. As more knowledge is gathered on the sensing regulatory component, the possibility of developing targeted or pollutant-specific biosensors is promising. Moreover, the repertoire of biosensors for culprit organic pollutants is expected to be enlarged through advances in genomics technology and identification of new sensory or receptor molecules. The need for pollutant detection at concentrations in the parts per trillion range or biosensors configured in a nanoscale is anticipated.
Collapse
Affiliation(s)
- Angela Keane
- Department of Civil Engineering and Applied Mechanics, McGill University, Montreal, Quebec, Canada
| | | | | | | |
Collapse
|