Wolf J, Buckley GJ, Rozanski EA, Fletcher DJ, Boller M, Burkitt-Creedon JM, Weigand KA, Crews M, Fausak ED. 2024 RECOVER Guidelines: Advanced Life Support. Evidence and knowledge gap analysis with treatment recommendations for small animal CPR. J Vet Emerg Crit Care (San Antonio) 2024; 34 Suppl 1:44-75. [PMID: 38924633 DOI: 10.1111/vec.13389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 04/25/2024] [Indexed: 06/28/2024]
Abstract
OBJECTIVE To systematically review the evidence and devise clinical recommendations on advanced life support (ALS) in dogs and cats and to identify critical knowledge gaps. DESIGN Standardized, systematic evaluation of literature pertinent to ALS following Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology. Prioritized questions were each reviewed by Evidence Evaluators, and findings were reconciled by ALS Domain Chairs and Reassessment Campaign on Veterinary Resuscitation (RECOVER) Co-Chairs to arrive at treatment recommendations commensurate to quality of evidence, risk:benefit relationship, and clinical feasibility. This process was implemented using an Evidence Profile Worksheet for each question that included an introduction, consensus on science, treatment recommendations, justification for these recommendations, and important knowledge gaps. A draft of these worksheets was distributed to veterinary professionals for comment for 4 weeks prior to finalization. SETTING Transdisciplinary, international collaboration in university, specialty, and emergency practice. RESULTS Seventeen questions pertaining to vascular access, vasopressors in shockable and nonshockable rhythms, anticholinergics, defibrillation, antiarrhythmics, and adjunct drug therapy as well as open-chest CPR were reviewed. Of the 33 treatment recommendations formulated, 6 recommendations addressed the management of patients with nonshockable arrest rhythms, 10 addressed shockable rhythms, and 6 provided guidance on open-chest CPR. We recommend against high-dose epinephrine even after prolonged CPR and suggest that atropine, when indicated, is used only once. In animals with a shockable rhythm in which initial defibrillation was unsuccessful, we recommend doubling the defibrillator dose once and suggest vasopressin (or epinephrine if vasopressin is not available), esmolol, lidocaine in dogs, and/or amiodarone in cats. CONCLUSIONS These updated RECOVER ALS guidelines clarify the approach to refractory shockable rhythms and prolonged CPR. Very low quality of evidence due to absence of clinical data in dogs and cats continues to compromise the certainty with which recommendations can be made.
Collapse
Affiliation(s)
- Jacob Wolf
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, USA
| | | | - Elizabeth A Rozanski
- Department of Clinical Sciences, Tufts University School of Veterinary Medicine, North Grafton, Massachusetts, USA
| | - Daniel J Fletcher
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA
| | - Manuel Boller
- VCA Canada Central Victoria Veterinary Hospital, Victoria, British Columbia, Canada
- Faculty of Veterinary Medicine, Department of Veterinary Clinical and Diagnostic Sciences, University of Calgary, Calgary, Alberta, Canada
| | - Jamie M Burkitt-Creedon
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, Davis, California, USA
| | - Kelly A Weigand
- Cary Veterinary Medical Library, Auburn University, Auburn, Alabama, USA
- Flower-Sprecher Veterinary Library, Cornell University, Ithaca, New York, USA
| | - Molly Crews
- Department of Small Animal Clinical Sciences, Texas A&M University College of Veterinary Medicine & Biomedical Sciences, College Station, Texas, USA
| | - Erik D Fausak
- University Library, University of California, Davis, Davis, California, USA
| |
Collapse
|
2
|
Dreyfuss A, Carlson GK. Defibrillation in the Cardiac Arrest Patient. Emerg Med Clin North Am 2023; 41:529-542. [PMID: 37391248 DOI: 10.1016/j.emc.2023.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/02/2023]
Abstract
Defibrillation is one of the few interventions known to favorably impact survival in cardiac arrest. In witnessed arrest, survival improves with defibrillation as early as possible, whereas it may improve outcomes to administer high-quality chest compressions for 90 seconds before defibrillation in unwitnessed arrest. Minimizing pre-, peri-, and post-shock pauses has been shown to have mortality benefits. Refractory ventricular fibrillation has high mortality rates, and there is ongoing research into promising adjunctive treatment modalities. There remains no consensus on optimal pad positioning and defibrillation energy level, however, recent data suggest anteroposterior pad placement may be superior to anterolateral placement.
Collapse
Affiliation(s)
- Andrea Dreyfuss
- Department of Emergency Medicine, Hennepin Hospital, 701 Park Avenue, Minneapolis, MN 55415, USA.
| | | |
Collapse
|
3
|
Pocock H, Deakin CD, Lall R, Smith CM, Perkins GD. Effectiveness of alternative shock strategies for out-of-hospital cardiac arrest: A systematic review. Resusc Plus 2022; 10:100232. [PMID: 35602465 PMCID: PMC9114679 DOI: 10.1016/j.resplu.2022.100232] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 03/18/2022] [Accepted: 04/02/2022] [Indexed: 11/24/2022] Open
Abstract
Aim To determine the optimal first-shock energy level for biphasic defibrillation and whether fixed or escalating protocols for subsequent shocks are most effective. Methods We searched Medline, Embase, Cochrane CENTRAL, CINAHL, the Web of Science and national and international trial registry databases for papers published from database inception to January 2022. We reviewed reference lists of key papers to identify additional references. The population included adults sustaining non traumatic out-of-hospital cardiac arrest subject to attempted defibrillation. Studies of internal or monophasic defibrillation and studies other than randomised controlled trials or prospective cohorts were excluded. Two reviewers assessed study relevance. Data extraction and risk of bias assessment, using the ROBINS-I tool, were conducted by one reviewer and checked by a second reviewer. Data underwent intention-to-treat analysis. Results We identified no studies evaluating first shock energy. Only one study (n = 738) comparing fixed versus escalating energy met eligibility criteria: a prospective cohort analysis of a randomised controlled trial of manual versus mechanical CPR. High fixed (360 J) energy was compared with an escalating (200-200/300-360 J) strategy. Researchers found 27.5% (70/255) of patients in the escalating energy group and 27.61% (132/478) in the fixed high energy group survived to hospital discharge (unadjusted risk ratio 0.99, 95% CI 0.73, 1.23). Results were of very low certainty as the study was at serious risk of bias. Conclusion This systematic review did not identify an optimal first-shock energy for biphasic defibrillation. We identified no survival advantage at 30 days when comparing 360 J fixed with 200 J escalating strategy.
Collapse
Affiliation(s)
- Helen Pocock
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
- South Central Ambulance Service NHS Foundation Trust, Southern House, Sparrowgrove, Otterbourne, Winchester SO21 2RU, United Kingdom
| | - Charles D Deakin
- South Central Ambulance Service NHS Foundation Trust, Southern House, Sparrowgrove, Otterbourne, Winchester SO21 2RU, United Kingdom
- University Hospital Southampton NHS Foundation Trust, Tremona Road, Southampton, SO16 6YD, United Kingdom
| | - Ranjit Lall
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
| | - Christopher M Smith
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
| | - Gavin D Perkins
- Warwick Clinical Trials Unit, Warwick Medical School, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, United Kingdom
- University Hospitals Birmingham NHS Foundation Trust, Birmingham Heartlands Hospital, Bordesley Green East, Birmingham B9 5SS, United Kingdom
| |
Collapse
|
4
|
Mercier E, Laroche E, Beck B, Le Sage N, Cameron PA, Émond M, Berthelot S, Mitra B, Ouellet-Pelletier J. Defibrillation energy dose during pediatric cardiac arrest: Systematic review of human and animal model studies. Resuscitation 2019; 139:241-252. [DOI: 10.1016/j.resuscitation.2019.04.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 03/25/2019] [Accepted: 04/16/2019] [Indexed: 10/27/2022]
|
5
|
|
6
|
|
7
|
Maconochie IK, Bingham R, Eich C, López-Herce J, Rodríguez-Núñez A, Rajka T, Van de Voorde P, Zideman DA, Biarent D, Monsieurs KG, Nolan JP. European Resuscitation Council Guidelines for Resuscitation 2015. Resuscitation 2015; 95:223-48. [DOI: 10.1016/j.resuscitation.2015.07.028] [Citation(s) in RCA: 217] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
8
|
The Use of Automated External Defibrillators in Infants: A Report From the American Red Cross Scientific Advisory Council. Pediatr Emerg Care 2015; 31:526-30. [PMID: 26148104 DOI: 10.1097/pec.0000000000000490] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Automated external defibrillators (AEDs) have been used successfully in many populations to improve survival for out-of-hospital cardiac arrest. While ventricular fibrillation and pulseless ventricular tachycardia are more prevalent in adults, these arrhythmias do occur in infants. The Scientific Advisory Council of the American Red Cross reviewed the literature on the use of AEDs in infants in order to make recommendations on use in the population. METHODS The Cochrane library and PubMed were searched for studies that included AEDs in infants, any external defibrillation in infants, and simulation studies of algorithms used by AEDs on pediatric arrhythmias. RESULTS There were 4 studies on the accuracy of AEDs in recognizing pediatric arrhythmias. Case reports (n = 2) demonstrated successful use of AED in infants, and a retrospective review (n = 1) of pediatric pads for AEDs included infants. Six studies addressed defibrillation dosages used. The algorithms used by AEDs had high sensitivity and specificity for pediatric arrhythmias and very rarely recommended a shock inappropriately. The energy doses delivered by AEDs were high, although in the range that have been used in out-of-hospital arrest. In addition, there are data to suggest that 2 to 4 J/kg may not be effective defibrillation doses for many children. CONCLUSIONS In the absence of prompt defibrillation for ventricular fibrillation or pulseless ventricular tachycardia, survival is unlikely. Automated external defibrillators should be used in infants with suspected cardiac arrest, if a manual defibrillator with a trained rescuer is not immediately available. Automated external defibrillators that attenuate the energy dose (eg, via application of pediatric pads) are recommended for infants. If an AED with pediatric pads is not available, the AED with adult pads should be used.
Collapse
|
9
|
Tanabe S, Yasunaga H, Koike S, Akahane M, Ogawa T, Horiguchi H, Hatanaka T, Yokota H, Imamura T. Monophasic versus biphasic defibrillation for pediatric out-of-hospital cardiac arrest patients: a nationwide population-based study in Japan. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2012; 16:R219. [PMID: 23148767 PMCID: PMC3672598 DOI: 10.1186/cc11864] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/10/2012] [Accepted: 11/09/2012] [Indexed: 01/11/2023]
Abstract
Introduction Conventional monophasic defibrillators for out-of-hospital cardiac-arrest patients have been replaced with biphasic defibrillators. However, the advantage of biphasic over monophasic defibrillation for pediatric out-of-hospital cardiac-arrest patients remains unknown. This study aimed to compare the survival outcomes of pediatric out-of-hospital cardiac-arrest patients who underwent monophasic defibrillation with those who underwent biphasic defibrillation. Methods This prospective, nationwide, population-based observational study included pediatric out-of-hospital cardiac-arrest patients from January 1, 2005, to December 31, 2009. The primary outcome measure was survival at 1 month with minimal neurologic impairment. The secondary outcome measures were survival at 1 month and the return of spontaneous circulation before hospital arrival. Multivariable logistic regression analysis was performed to identify the independent association between defibrillator type (monophasic or biphasic) and outcomes. Results Among 5,628 pediatric out-of-hospital cardiac-arrest patients (1 through 17 years old), 430 who received defibrillation shock with monophasic or biphasic defibrillator were analyzed. The number of patients who received defibrillation shock with monophasic defibrillator was 127 (30%), and 303 (70%) received defibrillation shock with biphasic defibrillator. The survival rates at 1 month with minimal neurologic impairment were 17.5% and 24.4%, the survival rates at 1 month were 32.3% and 35.6%, and the rates of return of spontaneous circulation before hospital arrival were 24.4% and 27.4% in the monophasic and biphasic defibrillator groups, respectively. Hierarchic logistic regression analyses by using generalized estimation equations found no significant difference between the two groups in terms of 1-month survival with minimal neurologic impairment (odds ratio (OR), 1.57; 95% confidence interval (CI), 0.87 to 2.83; P = 0.14) and 1-month survival (OR, 1.38; 95% CI, 0.87 to 2.18; P = 0.17). Conclusions The present nationwide population-based observational study could not confirm an advantage of biphasic over monophasic defibrillators for pediatric OHCA patients.
Collapse
|
10
|
Haskell SE, Atkins DL. Defibrillation in children. J Emerg Trauma Shock 2011; 3:261-6. [PMID: 20930970 PMCID: PMC2938491 DOI: 10.4103/0974-2700.66526] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2009] [Accepted: 04/24/2010] [Indexed: 12/04/2022] Open
Abstract
Defibrillation is the only effective treatment for ventricular fibrillation (VF). Optimal methods for defibrillation in children are derived and extrapolated from adult data. VF occurs as the initial rhythm in 8-20% of pediatric cardiac arrests. This has fostered a new interest in determining the optimal technique for pediatric defibrillation. This review will provide a brief background of the history of defibrillation and a review of the current literature on pediatric defibrillation. The literature search was performed through PubMed, using the MeSH headings of cardiopulmonary resuscitation, defibrillation and electric countershock. The authors’ personal bibliographic files were also searched. Only published articles were chosen. The recommended energy dose has been 2 J/kg for 30 years, but recent reports may indicate that higher dosages may be more effective and safe. In 2005, the European Resuscitation Council recommended 4 J/kg as the initial dose, without escalation for subsequent shocks. Automated external defibrillators are increasingly used for pediatric cardiac arrest, and available reports indicate high success rates. Additional research on pediatric defibrillation is critical in order to be able to provide an equivalent standard of care for children in cardiac arrest and improve outcomes.
Collapse
Affiliation(s)
- Sarah E Haskell
- Department of Pediatrics, University of Iowa Children's Hospital, University of Iowa Carver College of Medicine, 200 Hawks Drive, Iowa City, IA 52242, USA
| | | |
Collapse
|
11
|
Biarent D, Bingham R, Eich C, López-Herce J, Maconochie I, Rodríguez-Núñez A, Rajka T, Zideman D. European Resuscitation Council Guidelines for Resuscitation 2010 Section 6. Paediatric life support. Resuscitation 2011; 81:1364-88. [PMID: 20956047 DOI: 10.1016/j.resuscitation.2010.08.012] [Citation(s) in RCA: 151] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Dominique Biarent
- Paediatric Intensive Care, Hôpital Universitaire des Enfants, 15 av JJ Crocq, Brussels, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
de Caen AR, Kleinman ME, Chameides L, Atkins DL, Berg RA, Berg MD, Bhanji F, Biarent D, Bingham R, Coovadia AH, Hazinski MF, Hickey RW, Nadkarni VM, Reis AG, Rodriguez-Nunez A, Tibballs J, Zaritsky AL, Zideman D. Part 10: Paediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Resuscitation 2011; 81 Suppl 1:e213-59. [PMID: 20956041 DOI: 10.1016/j.resuscitation.2010.08.028] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Affiliation(s)
- Allan R de Caen
- Stollery Children's Hospital, University of Alberta, Canada.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
External and internal biphasic direct current shock doses for pediatric ventricular fibrillation and pulseless ventricular tachycardia. Pediatr Crit Care Med 2011; 12:14-20. [PMID: 20308928 DOI: 10.1097/pcc.0b013e3181dbb4fc] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To determine energy dose and number of biphasic direct current shocks for pediatric ventricular fibrillation (VF) and pulseless ventricular tachycardia (VT). DESIGN Observation of preshock and postshock rhythms, energy doses, and number of shocks. SETTING Pediatric hospital. PATIENTS Shockable ventricular dysrhythmias. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Forty-eight patients with VF or pulseless VT received external shock at 1.7 ± 0.8 (mean ± SD) J/kg. Return of spontaneous circulation (ROSC) occurred in 23 (48%) patients with 2.0 ± 1.0 J/kg, but 25 (52%) patients remained in VF after 1.5 ± 0.7 J/kg (p = .05). In 24 non-responding patients, additional 1-8 shocks (final dose, 2.8 ± 1.2 J/kg) achieved ROSC in 14 (58%) with 2.6 ± 1.1 J/kg but not in 10 (42%) with 3.2 ± 1.2 J/kg (not significant). Overall, 37 (77%) patients achieved ROSC with 2.2 ± 1.1 J/kg (range, 0.5-5.0 J/kg). Eight patients without ROSC recovered with cardiopulmonary bypass and internal direct current shock. At 13 subsequent episodes of VF or VT among eight patients, five achieved ROSC and survived. In combined first and subsequent resuscitative episodes, doses in the range of 2.5 to < 3 J/kg achieved most cases of ROSC. Survival for > 1 yr was seen in 28 (78%) of 36 patients with VF and seven (58%) of 11 patients with VT, with 35 (73%) overall. Lack of ROSC was associated with multiple shocks (p = .003). Repeated shocks with adhesive pads had significantly less impedance (p < .001). Pads in an anteroposterior position achieved highest ROSC rate. Internal shock for another 48 patients with VF or VT achieved ROSC in 28 (58%) patients with 0.7 ± 0.4 J/kg but not in 20 patients with 0.4 ± 0.3 J/kg (p = .01). Nineteen of the nonresponders who received additional internal 1-9 shocks at 0.6 ± 0.5 J/kg and one patient given extracorporeal membrane oxygenation all recovered, yielding 100% ROSC, but 1-yr survival tallied 43 (90%) patients. CONCLUSIONS The initial biphasic direct current external shock dose of 2 J/kg for VF or pulseless VT is inadequate. Appropriate doses for initial and subsequent shocks seem to be in the range of 3-5 J/kg. Multiple shocks do not favor ROSC. The dose for internal shock is 0.6-0.7 J/kg.
Collapse
|
14
|
Meaney PA, Nadkarni VM, Atkins DL, Berg MD, Samson RA, Hazinski MF, Berg RA. Effect of defibrillation energy dose during in-hospital pediatric cardiac arrest. Pediatrics 2011; 127:e16-23. [PMID: 21172997 DOI: 10.1542/peds.2010-1617] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To examine the effectiveness of initial defibrillation attempts. We hypothesized that (1) an initial shock dose of 2 ± 10 J/kg would be less effective for terminating fibrillation than suggested in published historical data and (2) a 4 J/kg shock dose would be more effective. PATIENTS AND METHODS This was a National Registry of Cardiopulmonary Resuscitation prospective, multisite, observational study of in-hospital pediatric (aged ≤18 years) ventricular fibrillation or pulseless ventricular tachycardia cardiac arrests from 2000-2008. Termination of ventricular fibrillation or pulseless ventricular tachycardia and event survival after initial shocks of 2 J/kg were compared with historic controls and a 4 J/kg shock dose. RESULTS Of 266 children with 285 events, 173 of 285 (61%) survived the event and 61 of 266 (23%) survived to discharge. Termination of fibrillation after initial shock was achieved for 152 of 285 (53%) events. Termination of fibrillation with 2 ± 10 J/kg was much less frequent than that seen among historic control subjects (56% vs 91%; P < .001), but not different than 4 J/kg. Compared with 2 J/kg, an initial shock dose of 4 J/kg was associated with lower rates of return of spontaneous circulation (odds ratio: 0.41 [95% confidence interval: 0.21-0.81]) and event survival (odds ratio: 0.42 [95% confidence interval: 0.18-0.98]). CONCLUSIONS The currently recommended 2 J/kg initial shock dose for in-hospital cardiac arrest was substantially less effective than previously published. A higher initial shock dose (4 J/kg) was not associated with superior termination of ventricular fibrillation or pulseless ventricular tachycardia or improved survival rates. The optimal pediatric defibrillation dose remains unknown.
Collapse
Affiliation(s)
- Peter A Meaney
- Department of Anesthesiology, Children's Hospital of Philadelphia, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania, USA
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Biarent D, Bingham R, Eich C, López-Herce J, Maconochie I, Rodrίguez-Núñez A, Rajka T, Zideman D. Lebensrettende Maßnahmen bei Kindern („paediatric life support“). Notf Rett Med 2010. [DOI: 10.1007/s10049-010-1372-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
16
|
Kleinman ME, Chameides L, Schexnayder SM, Samson RA, Hazinski MF, Atkins DL, Berg MD, de Caen AR, Fink EL, Freid EB, Hickey RW, Marino BS, Nadkarni VM, Proctor LT, Qureshi FA, Sartorelli K, Topjian A, van der Jagt EW, Zaritsky AL. Part 14: Pediatric Advanced Life Support. Circulation 2010; 122:S876-908. [DOI: 10.1161/circulationaha.110.971101] [Citation(s) in RCA: 473] [Impact Index Per Article: 31.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
17
|
Link MS, Atkins DL, Passman RS, Halperin HR, Samson RA, White RD, Cudnik MT, Berg MD, Kudenchuk PJ, Kerber RE. Part 6: Electrical Therapies. Circulation 2010; 122:S706-19. [DOI: 10.1161/circulationaha.110.970954] [Citation(s) in RCA: 223] [Impact Index Per Article: 14.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
18
|
Elektrotherapie: automatisierte externe Defibrillatoren, Defibrillation, Kardioversion und Schrittmachertherapie. Notf Rett Med 2010. [DOI: 10.1007/s10049-010-1369-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
19
|
Kleinman ME, de Caen AR, Chameides L, Atkins DL, Berg RA, Berg MD, Bhanji F, Biarent D, Bingham R, Coovadia AH, Hazinski MF, Hickey RW, Nadkarni VM, Reis AG, Rodriguez-Nunez A, Tibballs J, Zaritsky AL, Zideman D. Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Pediatrics 2010; 126:e1261-318. [PMID: 20956433 PMCID: PMC3784274 DOI: 10.1542/peds.2010-2972a] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
20
|
Kleinman ME, de Caen AR, Chameides L, Atkins DL, Berg RA, Berg MD, Bhanji F, Biarent D, Bingham R, Coovadia AH, Hazinski MF, Hickey RW, Nadkarni VM, Reis AG, Rodriguez-Nunez A, Tibballs J, Zaritsky AL, Zideman D. Part 10: Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Circulation 2010; 122:S466-515. [PMID: 20956258 PMCID: PMC3748977 DOI: 10.1161/circulationaha.110.971093] [Citation(s) in RCA: 143] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Note From the Writing Group: Throughout this article, the reader will notice combinations of superscripted letters and numbers (eg, “Family Presence During ResuscitationPeds-003”). These callouts are hyperlinked to evidence-based worksheets, which were used in the development of this article. An appendix of worksheets, applicable to this article, is located at the end of the text. The worksheets are available in PDF format and are open access.
Collapse
|
21
|
Deakin CD, Nolan JP, Sunde K, Koster RW. European Resuscitation Council Guidelines for Resuscitation 2010 Section 3. Electrical therapies: Automated external defibrillators, defibrillation, cardioversion and pacing. Resuscitation 2010; 81:1293-304. [DOI: 10.1016/j.resuscitation.2010.08.008] [Citation(s) in RCA: 101] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
22
|
Sahu S, Kishore K, Lata I. Better outcome after pediatric resuscitation is still a dilemma. J Emerg Trauma Shock 2010; 3:243-50. [PMID: 20930968 PMCID: PMC2938489 DOI: 10.4103/0974-2700.66524] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2009] [Accepted: 04/24/2010] [Indexed: 11/04/2022] Open
Abstract
Pediatric cardiac arrest is not a single problem. Although most episodes of pediatric cardiac arrest occur as complications and progression of respiratory failure and shock. Sudden cardiac arrest may result from abrupt and unexpected arrhythmias. With a better-tailored therapy, we can optimize the outcome. In the hospital, cardiac arrest often develops as a progression of respiratory failure and shock. Typically half or more of pediatric victims of in-hospital arrest have pre-existing respiratory failure and one-third or more have shock, although these figures vary somewhat among reporting hospitals. When in-hospital respiratory arrest or failure is treated before the development of cardiac arrest, survival ranges from 60% to 97%. Bradyarrthmia, asystole or pulseless electric activity (PEA) were recorded as an initial rhythm in half or more of the recent reports of in-hospital cardiac arrest, with survival to hospital discharge ranging from 22% to 40%. Data allowing characterization of out of hospital pediatric arrest are limited, although existing data support the long-held belief that as with hospitalized children, cardiac arrest most often occurs as a progression of respiratory failure or shock to cardiac arrest with bradyasystole rhythm. Although VF (Ventricular fibrillation, is a very rapid, uncoordinated, ineffective series of contractions throughout the lower chambers of the heart. Unless stopped, these chaotic impulses are fatal) and VT (Ventricular tachycardia is a rapid heartbeat that originates in one of the ventricles of the heart. To be classified as tachycardia, the heart rate is usually at least 100 beats per minute) are not common out-of-cardiac arrest in children, they are more likely to be present with sudden, witnessed collapse, particularly among adolescents. Pre-hospital care till the late 1980s was mainly concerned with adult care, and the initial focus for pediatric resuscitation was provision of oxygen and ventilation, with initial rhythm at the time of emergency medical services arrival being infrequently recorded. In the 1987 series, pre-hospital pediatric cardiac arrest demonstrated asystole in 80%, PEA in 10.5% and VF or VT in 9.6%. Only 29% arrests were witnessed, however, and death in many victims was caused by sudden infant death syndrome.
Collapse
Affiliation(s)
- Sandeep Sahu
- Department of Anaesthesiology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, UP, India
| | - Kamal Kishore
- Department of Anaesthesiology, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, UP, India
| | - Indu Lata
- Maternal & Reproductive Health, Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow, UP, India
| |
Collapse
|
23
|
Abstract
Although cardiac arrhythmias less commonly cause hemodynamic compromise in children than in adults, prompt recognition and treatment of arrhythmias remain an important part of pediatric resuscitation because of the availability of specific, effective therapies. This article summarizes the 2005 American Heart Association Guidelines for Pediatric Advanced Life Support regarding tachyarrhythmias, including treatment with antiarrhythmics and direct current countershock therapy, and provides an update of recent literature since the guidelines were published.
Collapse
|
24
|
Berg MD, Banville IL, Chapman FW, Walker RG, Gaballa MA, Hilwig RW, Samson RA, Kern KB, Berg RA. Attenuating the defibrillation dosage decreases postresuscitation myocardial dysfunction in a swine model of pediatric ventricular fibrillation. Pediatr Crit Care Med 2008; 9:429-34. [PMID: 18496405 PMCID: PMC2724893 DOI: 10.1097/pcc.0b013e318172e9f8] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The optimal biphasic defibrillation dose for children is unknown. Postresuscitation myocardial dysfunction is common and may be worsened by higher defibrillation doses. Adult-dose automated external defibrillators are commonly available; pediatric doses can be delivered by attenuating the adult defibrillation dose through a pediatric pads/cable system. The objective was to investigate whether unattenuated (adult) dose biphasic defibrillation results in greater postresuscitation myocardial dysfunction and damage than attenuated (pediatric) defibrillation. DESIGN Laboratory animal experiment. SETTING University animal laboratory. SUBJECTS Domestic swine weighing 19 +/- 3.6 kg. INTERVENTIONS Fifty-two piglets were randomized to receive biphasic defibrillation using either adult-dose shocks of 200, 300, and 360 J or pediatric-dose shocks of approximately 50, 75, and 85 J after 7 mins of untreated ventricular fibrillation. Contrast left ventriculograms were obtained at baseline and then at 1, 2, 3, and 4 hrs postresuscitation. Postresuscitation left ventricular ejection fraction and cardiac troponins were evaluated. MEASUREMENTS AND MAIN RESULTS By design, piglets in the adult-dose group received shocks with more energy (261 +/- 65 J vs. 72 +/- 12 J, p < .001) and higher peak current (37 +/- 8 A vs. 13 +/- 2 A, p < .001) at the largest defibrillation dose needed. In both groups, left ventricular ejection fraction was reduced significantly at 1, 2, and 4 hrs from baseline and improved during the 4 hrs postresuscitation. The decrease in left ventricular ejection fraction from baseline was greater after adult-dose defibrillation. Plasma cardiac troponin levels were elevated 4 hrs postresuscitation in 11 of 19 adult-dose piglets vs. four of 20 pediatric-dose piglets (p = .02). CONCLUSIONS Unattenuated adult-dose defibrillation results in a greater frequency of myocardial damage and worse postresuscitation myocardial function than pediatric doses in a swine model of prolonged out-of-hospital pediatric ventricular fibrillation cardiac arrest. These data support the use of pediatric attenuating electrodes with adult biphasic automated external defibrillators to defibrillate children.
Collapse
Affiliation(s)
- Marc D Berg
- University of Arizona Steele Children's Research Center, Tucson, AZ, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Wang J, Tang W, Brewer JE, Freeman G, Chang YT, Weil MH. Comparison of rectilinear biphasic waveform with biphasic truncated exponential waveform in a pediatric defibrillation model. Crit Care Med 2007; 35:1961-5. [PMID: 17581484 DOI: 10.1097/01.ccm.0000277505.00407.5d] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To compare the rectilinear biphasic waveform with a biphasic truncated exponential waveform for pediatric defibrillation. DESIGN Prospective, randomized study. SETTING Experimental laboratory of a university-affiliated research institute. SUBJECTS Male domestic piglets (4-24 kg). INTERVENTIONS Eleven piglets (4-8 kg), which represented a patient <1 yr old, and ten piglets (16-24 kg), which represented a pediatric patient between the ages of 2 and 8 yrs, were anesthetized, intubated, and mechanically ventilated. Ventricular fibrillation was induced and maintained for 30 secs, and a predetermined shock was then delivered to defibrillate. Following defibrillation, the animal was permitted to stabilize hemodynamically for 4 mins. Fifty shocks were applied to each animal using a randomization schedule based on a predetermined permutation of 50. The 50 shocks were 25 shocks for each rectilinear biphasic and biphasic truncated exponential waveforms, comprising five shocks at five energy settings. Each group of five shocks was fixed at a predetermined energy value, depending on the body weight of the animal. Dose-response curves were constructed using logistic regression. Aortic pressure, electrocardiogram, left ventricular pressure, and left ventricular pressure value of 40 mm Hg were continually measured. MEASUREMENTS AND MAIN RESULTS Dose-response curves determined defibrillation thresholds at 50% (D50) and 90% (D90) probability of success. The rectilinear biphasic waveform defibrillated with <90% of the D50 and D90 energies required for a biphasic truncated exponential waveform. The rectilinear biphasic waveform also successfully defibrillated with significantly less energy per body weight and per heart weight compared with a biphasic truncated exponential waveform. CONCLUSIONS The rectilinear biphasic waveform has superior defibrillation performance compared with a biphasic truncated exponential waveform in a piglet defibrillation model for young children.
Collapse
Affiliation(s)
- Jinglan Wang
- Weil Institute of Critical Care Medicine, Rancho Mirage, CA, USA
| | | | | | | | | | | |
Collapse
|
26
|
Markenson D, Pyles L, Neish S. Ventricular fibrillation and the use of automated external defibrillators on children. Pediatrics 2007; 120:e1368-79. [PMID: 17967922 DOI: 10.1542/peds.2007-2679] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The use of automated external defibrillators (AEDs) has been advocated in recent years as a part of the chain of survival to improve outcomes for adult cardiac arrest victims. When AEDs first entered the market, they were not tested for pediatric usage and rhythm interpretation. In addition, the presumption was that children do not experience ventricular fibrillation, so they would not benefit from use of AEDs. Recent literature has shown that children do experience ventricular fibrillation, and this rhythm has a better outcome than do other cardiac arrest rhythms. At the same time, the arrhythmia software on AEDs has become more extensive and validated for children, and attenuation devices have become available to downregulate the energy delivered by AEDs to allow their use in children. Pediatricians are now being asked whether AED programs should be implemented, and where they are being implemented, pediatricians are being asked to provide guidance on the use of AEDs in children. As AED programs expand, pediatricians must advocate on behalf of children so that their needs are accounted for in these programs. For pediatricians to be able to provide guidance and ensure that children are included in AED programs, it is important for pediatricians to know how AEDs work, be up-to-date on the literature regarding pediatric fibrillation and energy delivery, and understand the role of AEDs as life-saving interventions for children.
Collapse
|
27
|
Abstract
Cardiac arrest in children is not often due to a disturbance in rhythm that is amenable to electrical defibrillation, contrary to the situation in adults. When a shockable rhythm is present, defibrillation using an external electric shock applied at an early stage after pre-oxygenation and chest compressions is of proven efficacy. Success at conversion of ventricular fibrillation is dependent on the delay before delivering the shock and defibrillation efficiency, which is itself a function of thoracic impedance, energy dose and waveform.
Collapse
Affiliation(s)
- P Jones
- SMUR Pédiatrique, Réanimation Polyvalente (Paediatric Intensive Care), Hôpital Robert Debré APHP, 48 Boulevard Sérurier, 75935 Paris Cedex 19, France.
| | | |
Collapse
|
28
|
|
29
|
Liberman L, Hordof AJ, Altmann K, Pass RH. Low Energy Biphasic Waveform Cardioversion of Atrial Arrhythmias in Pediatric Patients and Young Adults. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 29:1383-6. [PMID: 17201846 DOI: 10.1111/j.1540-8159.2006.00551.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Low-dose biphasic waveform cardioversion has been used for the termination of atrial arrhythmias in adult patients. The energy required for termination of atrial arrhythmias in pediatric patients is not known. The objective of this study is to determine the minimum energy required for successful external cardioversion of atrial arrhythmias in pediatric patients using biphasic waveform current. METHODS Prospective study of all patients less than 24 years of age with and without congenital heart disease undergoing synchronized cardioversion for atrial arrhythmias. Patients were assigned to receive an initial biphasic energy shock of 0.2-0.5 J/kg and if unsuccessful in terminating the arrhythmia, subsequent sequential shocks of 1 and 2 J/kg would be administered until cardioversion was achieved. The end point of the cardioversion protocol was successful cardioversion or delivery of three shocks. RESULTS Between June 2005 and June 2006, 16 patients underwent biphasic cardioversion for atrial flutter or fibrillation. The mean age was 14.7 +/- 6.4 years (range: 2 weeks to 24 years). The mean weight was 51 +/- 21 kg (range: 3.8-82 kg). Seven patients had normal cardiac anatomy, three had a single ventricle (Fontan), two had a Senning operation; the remaining four patients had varied forms of congenital heart disease. The median length of time that the patients were in tachycardia was 12 hours (range: 5 minutes to 2 months). Using either transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE), no thrombi were identified in any patient. All patients were successfully cardioverted with biphasic waveform energy. The successful energy shock was 0.35 +/- 0.19 J/kg (range: 0.2-0.9 J/kg). All but one patient were successfully cardioverted with less than 0.5 J/kg. The transthoracic impedance range was between 41 and 144 Omega; one patient had an impedance of 506 Omega (2-week-old infant with a weight of 3.8 kg). The mean current delivered was 5.4 +/- 2.2 A (range: 1-11 A). CONCLUSION Low-dose energy using biphasic waveform shocks can be used for successful termination of atrial arrhythmias in pediatric patients with and without congenital heart disease.
Collapse
Affiliation(s)
- Leonardo Liberman
- Pediatric Arrhythmia Service, Department of Pediatrics, New York Presbyterian Hospital, Columbia University, New York, New York, USA.
| | | | | | | |
Collapse
|
30
|
Rossano JW, Quan L, Kenney MA, Rea TD, Atkins DL. Energy doses for treatment of out-of-hospital pediatric ventricular fibrillation. Resuscitation 2006; 70:80-9. [PMID: 16762479 DOI: 10.1016/j.resuscitation.2005.10.031] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2005] [Revised: 10/17/2005] [Accepted: 10/17/2005] [Indexed: 11/23/2022]
Abstract
AIM To investigate the energy dose used to treat out-of-hospital pediatric ventricular fibrillation and the survival rates of these patients. METHODS We reviewed three emergency medical systems (EMS) for their reports of patients under 1 month to 18 years who received shocks for ventricular fibrillation to determine the energy of each shock as well as other patient and care characteristics. Each patient's weight was estimated at the age-appropriate 50th and 95th percentiles. Patients were then grouped as receiving recommended energy doses (2 to < or = 4 J/kg), moderately high energy doses (> 4-6 J/kg), and high energy doses (> 6 J/kg). RESULTS Of 57 patients identified, 54% were male, with a mean age of 11 years, range 2 months to 17 years. Ventricular fibrillation was the initial rhythm in 80% (43/54) of patients. The mean number of shocks delivered was 3, with < or = 2 shocks delivered to 28 (49%) and > or = 5 shocks delivered to 10 (18%) patients. When evaluating all 185 shocks using the 50th percentile estimated weight, 45 (24%) shocks were at recommended doses, 56 (30%) were at moderately high energy doses, and 84 (45%) were high energy doses. Elevated energy dose was associated with an increasing number of shocks and lack of bystander CPR (p < .05). Nineteen (33%) patients survived to hospital discharge having received total doses up to 73 J/kg. Energy dose was not related to survival. CONCLUSION In this observational, multicenter out of hospital experience, children received a wide range of defibrillation doses, often exceeding recommended doses and equivalent to adult energy levels. Survival occurred at low and very high energy doses.
Collapse
Affiliation(s)
- Joseph W Rossano
- Department of Pediatrics, Baylor College of Medicine, Houston, TX, USA
| | | | | | | | | |
Collapse
|
31
|
2005 American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) of pediatric and neonatal patients: pediatric advanced life support. Pediatrics 2006; 117:e1005-28. [PMID: 16651281 DOI: 10.1542/peds.2006-0346] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
32
|
The International Liaison Committee on Resuscitation (ILCOR) consensus on science with treatment recommendations for pediatric and neonatal patients: pediatric basic and advanced life support. Pediatrics 2006; 117:e955-77. [PMID: 16618790 DOI: 10.1542/peds.2006-0206] [Citation(s) in RCA: 151] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
This publication contains the pediatric and neonatal sections of the 2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations (COSTR). The consensus process that produced this document was sponsored by the International Liaison Committee on Resuscitation (ILCOR). ILCOR was formed in 1993 and consists of representatives of resuscitation councils from all over the world. Its mission is to identify and review international science and knowledge relevant to cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) and to generate consensus on treatment recommendations. ECC includes all responses necessary to treat life-threatening cardiovascular and respiratory events. The COSTR document presents international consensus statements on the science of resuscitation. ILCOR member organizations are each publishing resuscitation guidelines that are consistent with the science in this consensus document, but they also take into consideration geographic, economic, and system differences in practice and the regional availability of medical devices and drugs. The American Heart Association (AHA) pediatric and the American Academy of Pediatrics/AHA neonatal sections of the resuscitation guidelines are reprinted in this issue of Pediatrics (see pages e978-e988). The 2005 evidence evaluation process began shortly after publication of the 2000 International Guidelines for CPR and ECC. The process included topic identification, expert topic review, discussion and debate at 6 international meetings, further review, and debate within ILCOR member organizations and ultimate approval by the member organizations, an Editorial Board, and peer reviewers. The complete COSTR document was published simultaneously in Circulation (International Liaison Committee on Resuscitation. 2005 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Circulation. 2005;112(suppl):73-90) and Resuscitation (International Liaison Committee on Resuscitation. 2005 International Consensus Conference on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Resuscitation. 2005;67:271-291). Readers are encouraged to review the 2005 COSTR document in its entirety. It can be accessed through the CPR and ECC link at the AHA Web site: www.americanheart.org. The complete publication represents the largest evaluation of resuscitation literature ever published and contains electronic links to more detailed information about the international collaborative process. To organize the evidence evaluation, ILCOR representatives established 6 task forces: basic life support, advanced life support, acute coronary syndromes, pediatric life support, neonatal life support, and an interdisciplinary task force to consider overlapping topics such as educational issues. The AHA established additional task forces on stroke and, in collaboration with the American Red Cross, a task force on first aid. Each task force identified topics requiring evaluation and appointed international experts to review them. A detailed worksheet template was created to help the experts document their literature review, evaluate studies, determine levels of evidence, develop treatment recommendations, and disclose conflicts of interest. Two evidence evaluation experts reviewed all worksheets and assisted the worksheet reviewers to ensure that the worksheets met a consistently high standard. A total of 281 experts completed 403 worksheets on 275 topics, reviewing more than 22000 published studies. In December 2004 the evidence review and summary portions of the evidence evaluation worksheets, with worksheet author conflict of interest statements, were posted on the Internet at www.C2005.org, where readers can continue to access them. Journal advertisements and e-mails invited public comment. Two hundred forty-nine worksheet authors (141 from the United States and 108 from 17 other countries) and additional invited experts and reviewers attended the 2005 International Consensus Conference for presentation, discussion, and debate of the evidence. All 380 participants at the conference received electronic copies of the worksheets. Internet access was available to all conference participants during the conference to facilitate real-time verification of the literature. Expert reviewers presented topics in plenary, concurrent, and poster conference sessions with strict adherence to a novel and rigorous conflict of interest process. Presenters and participants then debated the evidence, conclusions, and draft summary statements. Wording of science statements and treatment recommendations was refined after further review by ILCOR member organizations and the international editorial board. This format ensured that the final document represented a truly international consensus process. The COSTR manuscript was ultimately approved by all ILCOR member organizations and by an international editorial board. The AHA Science Advisory and Coordinating Committee and the editor of Circulation obtained peer reviews of this document before it was accepted for publication. The most important changes in recommendations for pediatric resuscitation since the last ILCOR review in 2000 include: Increased emphasis on performing high quality CPR: "Push hard, push fast, minimize interruptions of chest compression; allow full chest recoil, and don't provide excessive ventilation" Recommended chest compression-ventilation ratio: For lone rescuers with victims of all ages: 30:2 For health care providers performing 2-rescuer CPR for infants and children: 15:2 (except 3:1 for neonates) Either a 2- or 1-hand technique is acceptable for chest compressions in children Use of 1 shock followed by immediate CPR is recommended for each defibrillation attempt, instead of 3 stacked shocks Biphasic shocks with an automated external defibrillator (AED) are acceptable for children 1 year of age. Attenuated shocks using child cables or activation of a key or switch are recommended in children <8 years old. Routine use of high-dose intravenous (IV) epinephrine is no longer recommended. Intravascular (IV and intraosseous) route of drug administration is preferred to the endotracheal route. Cuffed endotracheal tubes can be used in infants and children provided correct tube size and cuff inflation pressure are used. Exhaled CO2 detection is recommended for confirmation of endotracheal tube placement. Consider induced hypothermia for 12 to 24 hours in patients who remain comatose following resuscitation. Some of the most important changes in recommendations for neonatal resuscitation since the last ILCOR review in 2000 include less emphasis on using 100% oxygen when initiating resuscitation, de-emphasis of the need for routine intrapartum oropharyngeal and nasopharyngeal suctioning for infants born to mothers with meconium staining of amniotic fluid, proven value of occlusive wrapping of very low birth weight infants <28 weeks' gestation to reduce heat loss, preference for the IV versus the endotracheal route for epinephrine, and an increased emphasis on parental autonomy at the threshold of viability. The scientific evidence supporting these recommendations is summarized in the neonatal document (see pages e978-e988).
Collapse
|
33
|
Batra AS, Hasan BS, Hurwitz RA. Efficacy of biphasic waveform compared to monophasic waveform for cardioversion of atrial flutter in pediatric patients. Pediatr Cardiol 2006; 27:230-3. [PMID: 16391991 DOI: 10.1007/s00246-005-1112-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The efficacy of biphasic waveform cardioversion of atrial flutter in pediatric patients has not previously been demonstrated. Cardioversion outcomes were compared in two sequential groups of patients with atrial flutter undergoing transthoracic cardioversion using monophasic and biphasic waveforms at a single pediatric institution. The mean energy required for procedural success was 1.7 +/- 1.2 J/kg in the monophasic group compared to 0.9 +/- 0.6 J/kg in the biphasic group (p = 0.002). The mean number of attempts before achieving procedural success was 1.9 +/- 1.2 for the monophasic group and 1.3 +/- 1.0 for the biphasic group (p = 0.019). Procedure success rate was 89.5% (33/38) in the monophasic group compared to 100% (27/27) in the biphasic group (p = 0.13). Success rate for biphasic waveform cardioversion was 83% (5/6) when using energy less than 0.5 J/kg. These findings provide the impetus for lower starting energies and more widespread use of devices utilizing biphasic waveforms in pediatric patients.
Collapse
Affiliation(s)
- A S Batra
- Division of Cardiology, Department of Pediatrics, Indiana University School of Medicine, Indianapolis, IN 46202, USA.
| | | | | |
Collapse
|
34
|
Elektrische Therapie: automatisierte externe Defibrillatoren, Defibrillation, Kardioversion und Schrittmachertherapie. Notf Rett Med 2006. [DOI: 10.1007/s10049-006-0793-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
35
|
|
36
|
Hammill WW, Butler J. Pediatric Advanced Life Support Update for Emergency Department Physicians. CLINICAL PEDIATRIC EMERGENCY MEDICINE 2005. [DOI: 10.1016/j.cpem.2005.09.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
37
|
|
38
|
Biarent D, Bingham R, Richmond S, Maconochie I, Wyllie J, Simpson S, Nunez AR, Zideman D. European Resuscitation Council Guidelines for Resuscitation 2005. Resuscitation 2005; 67 Suppl 1:S97-133. [PMID: 16321719 DOI: 10.1016/j.resuscitation.2005.10.010] [Citation(s) in RCA: 172] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
39
|
Atkins DL, Jorgenson DB. Attenuated pediatric electrode pads for automated external defibrillator use in children. Resuscitation 2005; 66:31-7. [PMID: 15993727 DOI: 10.1016/j.resuscitation.2004.12.025] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2004] [Revised: 12/17/2004] [Accepted: 12/17/2004] [Indexed: 10/25/2022]
Abstract
OBJECTIVE This post-market, observational study is intended to evaluate reported uses of pediatric pads that reduce the energy delivered by some adult automated external defibrillators (AEDs) so that they may be used with pediatric patients. METHODS Users of the pediatric pads were asked to report any use of the pads, even if no shock was delivered and to provide detailed information about the event, caregiver and the patient. RESULTS Reports of the use of pediatric pads have been received and confirmed for 27 patients, age range 0 days to 23 years, median 2 years. Ventricular fibrillation (VF) was reported in eight cases, age range 4.5 months to 10 years, median 3 years. Shocks were delivered to all VF patients, the average shock number was 1.9, range 1-4. All patients had termination of VF, were admitted to the hospital and five survived to hospital discharge. Non-shockable rhythms were reported in 16 patients, and the AED appropriately did not advise a shock. Eleven of these patients had asystole or PEA as their initial rhythm and did not survive to hospital discharge. One report contained no additional information other than that the patient did not survive, and in two other reports, the pads were not applied to patients. CONCLUSIONS Voluntary reports of the use of attenuated pediatric defibrillation pads indicate the devices performed appropriately. All eight VF patients had termination of VF and five survived to hospital discharge. These data support the rapid deployment of AEDs for young children as well as adolescents and adults. Since the pediatric pads are available and deliver an appropriate dose for children, their use should be strongly encouraged.
Collapse
Affiliation(s)
- Dianne L Atkins
- The Children's Hospital of Iowa, Department of Pediatrics, The University of Iowa, Carver College of Medicine, Iowa City, IA 52240, USA.
| | | |
Collapse
|
40
|
|
41
|
Berg RA, Samson RA, Berg MD, Chapman FW, Hilwig RW, Banville I, Walker RG, Nova RC, Anavy N, Kern KB. Better outcome after pediatric defibrillation dosage than adult dosage in a swine model of pediatric ventricular fibrillation. J Am Coll Cardiol 2005; 45:786-9. [PMID: 15734626 DOI: 10.1016/j.jacc.2004.11.040] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2004] [Revised: 11/03/2004] [Accepted: 11/11/2004] [Indexed: 10/25/2022]
Abstract
OBJECTIVES This study was designed to compare outcome after adult defibrillation dosing versus pediatric dosing in a piglet model of prolonged prehospital ventricular fibrillation (VF). BACKGROUND Weight-based 2 to 4 J/kg monophasic defibrillation dosing is recommended for children in VF, but impractical for automated external defibrillator (AED) use. Present AEDs can only provide adult shock doses or newly developed attenuated adult doses intended for children. A single escalating energy sequence (50/75/86 J) of attenuated adult-dose biphasic shocks (pediatric dosing) is at least as effective as escalating monophasic weight-based dosing for prolonged VF in piglets, but this approach has not been compared to standard adult biphasic dosing. METHODS Following 7 min of untreated VF, piglets weighing 13 to 26 kg (19 +/- 1 kg) received either biphasic 50/75/86 J (pediatric dose) or biphasic 200/300/360 J (adult dose) therapies during simulated prehospital life support. RESULTS Return of spontaneous circulation was attained in 15 of 16 pediatric-dose piglets and 14 of 16 adult-dose piglets. Four hours postresuscitation, pediatric dosing resulted in fewer elevations of cardiac troponin T (0 of 12 piglets vs. 6 of 11 piglets, p = 0.005) and less depression of left ventricular ejection fraction (p < 0.05). Most importantly, more piglets survived to 24 h with good neurologic scores after pediatric shocks than adult shocks (13 of 16 piglets vs. 4 of 16 piglets, p = 0.004). CONCLUSIONS In this model, pediatric shocks resulted in superior outcome compared with adult shocks. These data suggest that adult defibrillation dosing may be harmful to pediatric patients with VF and support the use of attenuating electrodes with adult biphasic AEDs to defibrillate children.
Collapse
Affiliation(s)
- Robert A Berg
- University of Arizona Steele Memorial Children's Research Center, Tucson, Arizona, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Berg RA. Attenuated adult biphasic shocks for prolonged pediatric ventricular fibrillation: support for pediatric automated defibrillators. Crit Care Med 2004; 32:S352-5. [PMID: 15508658 DOI: 10.1097/01.ccm.0000134225.42482.dc] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate published data regarding the treatment of prolonged pediatric defibrillation, with special emphasis on the use of attenuated adult biphasic shocks for pediatric defibrillation. DESIGN Review relevant human and animal literature. RESULTS Rhythm analysis algorithms from two manufacturers of automated external defibrillators can accurately distinguish shockable from nonshockable rhythms in children. Theoretical considerations and transthoracic impedance data from animals and children suggest that pediatric defibrillation doses should not necessarily vary in a simple weight-based manner. Two piglet studies have established that an attenuated adult biphasic dosage can be successfully used for 3.5- to 24-kg animals in ventricular fibrillation. One study established that the attenuated adult biphasic dosage was at least as safe and effective as the standard monophasic weight-based dosing. CONCLUSION This review supports the American Heart Association's new guidelines for pediatric automated external defibrillator usage: "Automated external defibrillators may be used for children 1 to 8 yrs of age who have no signs of circulation. Ideally the device should deliver a pediatric dose. The arrhythmia detection system used in the device should demonstrate high specificity for pediatric shockable rhythms, i.e., it will not recommend delivery of a shock for nonshockable rhythms."
Collapse
Affiliation(s)
- Robert A Berg
- University of Arizona Steele Memorial Children's Research Center and Sarver Heart Center, Department of Pediatrics, Tucson, AZ, USA
| |
Collapse
|
43
|
Atkins DL, Kenney MA. Automated external defibrillators: safety and efficacy in children and adolescents. Pediatr Clin North Am 2004; 51:1443-62. [PMID: 15331293 DOI: 10.1016/j.pcl.2004.04.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Although children do not suffer from ventricular fibrillation (VF) as frequently as adults, it does occur in 10% to 20% of pediatric cardiac arrests. The technology is available to recognize and treat ventricular fibrillation in children as quickly as we can for adults. This article discusses the evidence to support automated external defibrillator use in young children. As this technology gains increased acceptance, resuscitation rates and outcomes for VF in children should approach those that are seen in adults.
Collapse
Affiliation(s)
- Dianne L Atkins
- Division of Pediatric Cardiology, Roy J. and Lucille A. Carver College of Medicine, 200 Hawkins Drive, University of Iowa, Iowa City, IA 52242, USA.
| | | |
Collapse
|
44
|
Berg RA, Chapman FW, Berg MD, Hilwig RW, Banville I, Walker RG, Nova RC, Sherrill D, Kern KB. Attenuated adult biphasic shocks compared with weight-based monophasic shocks in a swine model of prolonged pediatric ventricular fibrillation. Resuscitation 2004; 61:189-97. [PMID: 15135196 DOI: 10.1016/j.resuscitation.2003.12.021] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2003] [Revised: 12/18/2003] [Accepted: 12/18/2003] [Indexed: 10/26/2022]
Abstract
AIM To compare the safety and efficacy of attenuated adult biphasic shocks with standard monophasic weight-based shocks in a piglet model of prolonged prehospital ventricular fibrillation (VF). BACKGROUND If attenuated adult shocks are safe and effective for prehospital pediatric VF, automated external defibrillators (AEDs) can be easily adapted for pediatric use. METHODS After 7 min of untreated VF, piglets were randomized to treatment with attenuated adult biphasic shocks or weight-based monophasic shocks. The attenuated adult biphasic group received 200/300/360 J shocks, attenuated by specialized pediatric electrodes to 51/78/81 J and the monophasic weight-based control group received 2/4/4 J/kg shocks. Forty-eight female piglets were studied, 16 in each of three weight categories: 4 kg (neonatal), 14 kg (younger child) and 24 kg (older child). The primary outcome measures of efficacy and safety were 24h survival with good neurological outcome and post-resuscitation left ventricular ejection fraction (LVEF), respectively. RESULTS For the 24 kg piglets, attenuated adult biphasic shocks resulted in superior 24 h survival with good neurological outcome (6/8 versus 0/8, P < 0.001) and greater LVEF 4 h post-resuscitation (34 +/- 4% versus 18 +/- 5%, P < 0.05). For the 14 and 4 kg piglets, 24 h survival with good neurological outcome occurred in 7/8 versus 5/8 and 7/8 versus 3/8, respectively, and LVEF 4 h post-resuscitation was 30 +/- 3% versus 36 +/- 6% and 30 +/- 3% versus 22 +/- 4%, respectively. CONCLUSIONS The escalating attenuated adult biphasic dosage strategy was at least as safe and effective as the standard weight-based monophasic dose over a wide range of weights in this piglet model of prehospital VF. This work supports the concept of using an attenuated adult biphasic dosage in children.
Collapse
Affiliation(s)
- Robert A Berg
- The University of Arizona Steele Memorial Children's Research Center, Tuscon, AZ 85724-5073, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Jacobs IG, Tibballs J, Morley PT, Dennett J, Wassertheil J, Callanan V, Hall J. Energy levels for biphasic defibrillation. Med J Aust 2003; 179:451. [PMID: 14558874 DOI: 10.5694/j.1326-5377.2003.tb05631.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2003] [Accepted: 07/17/2003] [Indexed: 11/17/2022]
|
46
|
Samson RA, Berg RA, Bingham R. Use of automated external defibrillators for children: an update--an advisory statement from the Pediatric Advanced Life Support Task Force, International Liaison Committee on Resuscitation. Pediatrics 2003; 112:163-8. [PMID: 12837882 DOI: 10.1542/peds.112.1.163] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Affiliation(s)
- Ricardo A Samson
- Department of Pediatrics, 1501 N Campbell, Tucson, AZ 85724-5073, USA.
| | | | | |
Collapse
|
47
|
Samson RA, Berg RA, Bingham R, Biarent D, Coovadia A, Hazinski MF, Hickey RW, Nadkarni V, Nichol G, Tibballs J, Reis AG, Tse S, Zideman D, Potts J, Uzark K, Atkins D. Use of automated external defibrillators for children: an update: an advisory statement from the pediatric advanced life support task force, International Liaison Committee on Resuscitation. Circulation 2003; 107:3250-5. [PMID: 12835409 DOI: 10.1161/01.cir.0000074201.73984.fd] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
48
|
Samson R, Berg R, Bingham R. Use of automated external defibrillators for children: an update. An advisory statement from the Pediatric Advanced Life Support Task Force, International Liaison Committee on Resuscitation. Resuscitation 2003; 57:237-43. [PMID: 12858859 DOI: 10.1016/s0300-9572(03)00202-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
49
|
Link MS, Maron BJ, Stickney RE, Vanderbrink BA, Zhu W, Pandian NG, Wang PJ, Estes NAM. Automated external defibrillator arrhythmia detection in a model of cardiac arrest due to commotio cordis. J Cardiovasc Electrophysiol 2003; 14:83-7. [PMID: 12625616 DOI: 10.1046/j.1540-8167.2003.02017.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Cardiac arrest due to chest wall blows (commotio cordis) has been reported with increasing frequency in children, and only about 15% of victims survive. Automated external defibrillators (AEDs) have been shown to be life saving in adults with cardiac arrest, but data on their use in children are limited. In a swine model of commotio cordis designed to be most relevant to young children, we assessed the efficacy of a commercially available AED for recognition and termination of ventricular fibrillation. METHODS AND RESULTS Ventricular fibrillation was produced in anesthetized juvenile swine by precordial impact from a baseball under controlled conditions. Animals were randomized to defibrillation after 1, 2, 4, or 6 minutes of ventricular fibrillation. Twenty-six swine underwent 50 ventricular fibrillation inductions. Sensitivity of the AED for recognition of ventricular fibrillation was 98%, and specificity for nonshockable episodes was 100%. All episodes of ventricular fibrillation were successfully terminated by the AED. CONCLUSION In this experimental model of commotio cordis, the AED proved to be highly sensitive and specific for recognition of ventricular fibrillation and effective in terminating the arrhythmia and restoring sinus rhythm. These findings suggest that early defibrillation with the AED could save young lives on the athletic field.
Collapse
Affiliation(s)
- Mark S Link
- Tufts University School of Medicine and New England Medical Center, Boston, Massachusetts 02111, USA.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Killingsworth CR, Melnick SB, Chapman FW, Walker RG, Smith WM, Ideker RE, Walcott GP. Defibrillation threshold and cardiac responses using an external biphasic defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets. Resuscitation 2002; 55:177-85. [PMID: 12413756 DOI: 10.1016/s0300-9572(02)00157-0] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Before recommendations for using an automatic external defibrillator on pediatric patients can be made, a protocol for the energy of a biphasic waveform energy dosing needs to be determined that will allow ventricular defibrillation of 8 year olds while causing only a minimal amount of cardiac damage to infants. Pediatric- and adult-sized electrode patches were alternately applied to 10 isoflurane-anesthetized piglets weighing 3.8-20.1 kg to approximate the body weights of newborns to children < 8 years old. The defibrillation threshold (DFT) was determined for biphasic truncated exponential waveform shocks. Additional shocks, varying from the DFT to 360 Joules (J), were delivered during sinus rhythm or following 30 s of ventricular fibrillation (VF). The DFT was 2.4+/-0.81 and 2.1+/-0.65 J/kg for pediatric and adult patches, respectively (P = N.S.). The change in left ventricular (LV) dP/dt from baseline as a function of shock strength was significantly different at 1 and 10 s after shocks of increasing energy that were delivered in sinus rhythm, and 1, 10, 20, and 30 s after defibrillation shocks. There was no significant difference in LV dP/dt with increasing shock energy at 60 s with either patch size. The time to return of sinus rhythm, ST-segment deviation, and cardiac output were also not significantly different from baseline 60 s following shocks of up to 360 J delivered during sinus rhythm or VF with either patch. The same amount of energy delivered with a biphasic external defibrillator successfully defibrillated VF whether adult or pediatric patches were used. Cardiac rhythm and hemodynamic variables were unaltered at 60 s after shocks delivered at energies of up to 360 J. These data suggest that there is a substantial safety margin above a DFT strength shock for this biphasic waveform in piglets.
Collapse
Affiliation(s)
- Cheryl R Killingsworth
- Cardiac Rhythm Management Laboratory, Department of Medicine, Division of Cardiovascular Diseases, University of Alabama at Birmingham, 1670 University Boulevard, B140 Volker Hall, Birmingham, AL 35294, USA.
| | | | | | | | | | | | | |
Collapse
|