1
|
Li C, Guo Y, Lin X, Feng X, Xu D, Yang R. Deep reinforcement learning in radiation therapy planning optimization: A comprehensive review. Phys Med 2024; 125:104498. [PMID: 39163802 DOI: 10.1016/j.ejmp.2024.104498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 07/08/2024] [Accepted: 08/06/2024] [Indexed: 08/22/2024] Open
Abstract
PURPOSE The formulation and optimization of radiation therapy plans are complex and time-consuming processes that heavily rely on the expertise of medical physicists. Consequently, there is an urgent need for automated optimization methods. Recent advancements in reinforcement learning, particularly deep reinforcement learning (DRL), show great promise for automating radiotherapy planning. This review summarizes the current state of DRL applications in this field, evaluates their effectiveness, and identifies challenges and future directions. METHODS A systematic search was conducted in Google Scholar, PubMed, IEEE Xplore, and Scopus using keywords such as "deep reinforcement learning", "radiation therapy", and "treatment planning". The extracted data were synthesized for an overview and critical analysis. RESULTS The application of deep reinforcement learning in radiation therapy plan optimization can generally be divided into three categories: optimizing treatment planning parameters, directly optimizing machine parameters, and adaptive radiotherapy. From the perspective of disease sites, DRL has been applied to cervical cancer, prostate cancer, vestibular schwannoma, and lung cancer. Regarding types of radiation therapy, it has been used in HDRBT, IMRT, SBRT, VMAT, GK, and Cyberknife. CONCLUSIONS Deep reinforcement learning technology has played a significant role in advancing the automated optimization of radiation therapy plans. However, there is still a considerable gap before it can be widely applied in clinical settings due to three main reasons: inefficiency, limited methods for quality assessment, and poor interpretability. To address these challenges, significant research opportunities exist in the future, such as constructing evaluators, parallelized training, and exploring continuous action spaces.
Collapse
Affiliation(s)
- Can Li
- Institute of Operations Research and Information Engineering, Beijing University of Technology, Beijing 100124, PR China
| | - Yuqi Guo
- Institute of Operations Research and Information Engineering, Beijing University of Technology, Beijing 100124, PR China
| | - Xinyan Lin
- Department of Radiation Oncology, Cancer Center, Peking University Third Hospital, Beijing, 100191, China; School of Physics, Beihang University, Beijing, 102206, China
| | - Xuezhen Feng
- Department of Radiation Oncology, Cancer Center, Peking University Third Hospital, Beijing, 100191, China; School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China
| | - Dachuan Xu
- Institute of Operations Research and Information Engineering, Beijing University of Technology, Beijing 100124, PR China.
| | - Ruijie Yang
- Department of Radiation Oncology, Cancer Center, Peking University Third Hospital, Beijing, 100191, China.
| |
Collapse
|
2
|
Timakova E, Zavgorodni SF. Effect of modulation factor and low dose threshold level on gamma pass rates of single isocenter multi-target SRT treatment plans. J Appl Clin Med Phys 2024; 25:e14459. [PMID: 39053489 PMCID: PMC11492356 DOI: 10.1002/acm2.14459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 04/16/2024] [Accepted: 06/19/2024] [Indexed: 07/27/2024] Open
Abstract
PURPOSE SRS MapCHECK (SMC) is a commercially available patient-specific quality assurance (PSQA) tool for stereotactic radiosurgery (SRS) applications. This study investigates the effects of degree of modulation, location off-axis, and low dose threshold (LDT) selection on gamma pass rates (GPRs) between SMC and treatment planning system, Analytical Anisotropic Algorithm (AAA), or Vancouver Island Monte Carlo (VMC++ algorithm) system calculated dose distributions. METHODS Volumetric-modulated arc therapy (VMAT) plans with modulation factors (MFs) ranging from 2.7 to 10.2 MU/cGy were delivered to SMC at isocenter and 6 cm off-axis. SMC measured dose distributions were compared against AAA and VMC++ via gamma analysis (3%/1 mm) with LDT of 10% to 80% using SNC Patient software. RESULTS Comparing on-axis SMC dose against AAA and VMC++ with LDT of 10%, all AAA-calculated plans met the acceptance criteria of GPR ≥ 90%, and only one VMC++ calculated plan was marginally outside the acceptance criteria with pass rate of 89.1%. Using LDT of 80% revealed decreasing GPR with increasing MF. For AAA, GPRs reduced from 100% at MF of 2.7 MU/cGy to 57% at MF of 10.2 MU/cGy, and for VMC++ calculated plans, the GPRs reduced from 89% to 60% in the same MF range. Comparison of SMC dose off-axis against AAA and VMC++ showed more pronounced reduction of GPR with increasing MF. For LDT of 10%, AAA GPRs reduced from 100% to 83% in the MF range of 2.7 to 9.8 MU/cGy, and VMC++ GPR reduced from 100% to 91% in the same range. With 80% LDT, GPRs dropped from 100% to 42% for both algorithms. CONCLUSIONS MF, dose calculation algorithm, and LDT selections are vital in VMAT-based SRT PSQA. LDT of 80% enhances sensitivity of gamma analysis for detecting dose differences compared to 10% LDT. To achieve better agreement between calculated and SMC dose, it is recommended to limit the MF to 4.6 MU/cGy on-axis and 3.6 MU/cGy off-axis.
Collapse
Affiliation(s)
- Elena Timakova
- University of VictoriaVictoriaBritish ColumbiaCanada
- BC Cancer AgencyVancouver Island CentreVictoriaBritish ColumbiaCanada
| | - Sergei F. Zavgorodni
- University of VictoriaVictoriaBritish ColumbiaCanada
- BC Cancer AgencyVancouver Island CentreVictoriaBritish ColumbiaCanada
| |
Collapse
|
3
|
Mishra V, Chaudhary S, Singh P, Pandey L, Pandey A, Chatterjee R. Comparing Dosimetry of Heart and Left Anterior Descending Artery Exposure in Carcinoma Esophagus Patients: Volumetric Arc Therapy Versus Intensity-Modulated Radiotherapy. Cureus 2024; 16:e68182. [PMID: 39347339 PMCID: PMC11439471 DOI: 10.7759/cureus.68182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/29/2024] [Indexed: 10/01/2024] Open
Abstract
Introduction Esophageal cancer remains a leading cause of cancer-related mortality worldwide, with chemoradiotherapy being a cornerstone of its treatment. Ensuring precise radiation delivery is critical, as it minimizes exposure to surrounding healthy tissues, particularly vital structures like the heart and the left anterior descending artery (LAD). Volumetric arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) are two advanced radiotherapy techniques that offer enhanced dose conformity and reduced toxicity. This study conducts a retrospective dosimetric analysis to compare the effectiveness of VMAT and IMRT in sparing cardiac substructures and the LAD in patients with carcinoma of the esophagus. Methods Ten patients with middle-third esophageal cancer were treated using the VMAT technique with two coplanar arcs. These patients were retrospectively re-planned with IMRT using 7-9 fields on the Varian TrueBeam linear accelerator between June 2023 and December 2023. VMAT planning involved a two-phase approach: 45 Gy in 25 fractions followed by a boost of 5.4 Gy in three fractions. Dose-volume histograms were analyzed and compared for the planning target volume (PTV), heart and its substructures (including the right atrium, right ventricle, left atrium, and left ventricle), and the LAD. Statistical significance was determined using paired t-tests with a significance level set at P < 0.05. Results PTV coverage was comparable between VMAT and IMRT. VMAT resulted in higher low-dose exposure (V5 and V10) but offered better sparing at moderate doses (V20 and V40) for the heart. The LAD benefited from reduced high-dose exposure with VMAT. For other cardiac substructures, VMAT generally showed higher low-dose exposure but provided superior sparing at moderate doses compared to IMRT. Conclusions VMAT offers notable dosimetric advantages in sparing critical cardiac structures compared to IMRT for treating patients with middle third esophageal cancer. Long-term follow-up studies are needed to assess how these dosimetric benefits influence coronary artery disease and other cardiac complications.
Collapse
Affiliation(s)
- Vishwadeep Mishra
- Radiation Oncology, All India Institute of Medical Sciences, Gorakhpur, Gorakhpur, IND
| | - Shwetima Chaudhary
- Radiation Oncology, T.S Misra Medical College and Hospital, Lucknow, IND
| | - Prarabdh Singh
- Radiation Oncology, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Varanasi, Varanasi, IND
| | - Laxman Pandey
- Radiation Oncology, Rohilkhand Medical College and Hospital, Bareilly, IND
| | - Archana Pandey
- Radiation Oncology, Rohilkhand Medical College and Hospital, Bareilly, IND
| | - Rachita Chatterjee
- Pediatric Medicine, Baba Raghav Das (BRD) Medical College, Gorakhpur, IND
| |
Collapse
|
4
|
Roman RC, Moldovan MA, Pop LS, Megieșan S, Faur CI. Platelet-Rich Fibrin Treatment Evaluation in Patients with Medication-Related Osteonecrosis of the Jaw and Osteoradionecrosis. J Clin Med 2024; 13:3473. [PMID: 38930013 PMCID: PMC11204677 DOI: 10.3390/jcm13123473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 06/08/2024] [Accepted: 06/10/2024] [Indexed: 06/28/2024] Open
Abstract
Background. Medication-related osteonecrosis of the jaw (MRONJ) and osteoradionecrosis (ORN) are associated with severe disability and continuous pain, both of which are very difficult to control. This study aims to evaluate the outcome of platelet-rich fibrin (PRF) treatment compared to iodoform gauze packing and the primary suture of oral mucosa in patients with both MRONJ and ORN. Methods. Patients suffering from MRONJ and ORN who were treated in the Oral and Maxillofacial Surgery Clinic of Cluj-Napoca in the last 10 years were selected for this study from the hospital database. Results. PRF treatment proved to be a reliable method to help heal the necrotic bone sites. High-ASA risk patients and immunosuppressed patients are more prone to recurrence and persistent signs and symptoms. Intravenous bisphosphonates produce more intense symptomatology compared to oral administration. The posterior mandible is more difficult to treat compared to other sites. Conclusions. The quality of life of MRONJ and ORN patients may be improved by a protocol that reduces pain and hospitalization.
Collapse
Affiliation(s)
- Rareș Călin Roman
- Department of Oral and Maxillofacial Surgery and Implantology, Iuliu Hatieganu University of Medicine and Pharmacy Cluj-Napoca, 400006 Cluj-Napoca, Romania;
| | - Mădălina Anca Moldovan
- Department of Oral and Maxillofacial Surgery and Implantology, Iuliu Hatieganu University of Medicine and Pharmacy Cluj-Napoca, 400006 Cluj-Napoca, Romania;
| | - Loredana Sabrina Pop
- Faculty of Dental Medicine, Iuliu Hatieganu University of Medicine and Pharmacy Cluj-Napoca, 400006 Cluj-Napoca, Romania;
| | - Sergiu Megieșan
- Department of Mathematics, Imperial College London Alumni, London SW7 2AZ, UK;
| | - Cosmin Ioan Faur
- Department of Oral Radiology, Iuliu Hatieganu University of Medicine and Pharmacy Cluj-Napoca, 400006 Cluj-Napoca, Romania;
| |
Collapse
|
5
|
SHIRATO H. Biomedical advances and future prospects of high-precision three-dimensional radiotherapy and four-dimensional radiotherapy. PROCEEDINGS OF THE JAPAN ACADEMY. SERIES B, PHYSICAL AND BIOLOGICAL SCIENCES 2023; 99:389-426. [PMID: 37821390 PMCID: PMC10749389 DOI: 10.2183/pjab.99.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 09/13/2023] [Indexed: 10/13/2023]
Abstract
Biomedical advances of external-beam radiotherapy (EBRT) with improvements in physical accuracy are reviewed. High-precision (±1 mm) three-dimensional radiotherapy (3DRT) can utilize respective therapeutic open doors in the tumor control probability curve and in the normal tissue complication probability curve instead of the one single therapeutic window in two-dimensional EBRT. High-precision 3DRT achieved higher tumor control and probable survival rates for patients with small peripheral lung and liver cancers. Four-dimensional radiotherapy (4DRT), which can reduce uncertainties in 3DRT due to organ motion by real-time (every 0.1-1 s) tumor-tracking and immediate (0.1-1 s) irradiation, have achieved reduced adverse effects for prostate and pancreatic tumors near the digestive tract and with similar or better tumor control. Particle beam therapy improved tumor control and probable survival for patients with large liver tumors. The clinical outcomes of locally advanced or multiple tumors located near serial-type organs can theoretically be improved further by integrating the 4DRT concept with particle beams.
Collapse
Affiliation(s)
- Hiroki SHIRATO
- Global Center for Biomedical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| |
Collapse
|
6
|
Jang WI, Jo S, Moon JE, Bae SH, Park HC. The Current Evidence of Intensity-Modulated Radiotherapy for Hepatocellular Carcinoma: A Systematic Review and Meta-Analysis. Cancers (Basel) 2023; 15:4914. [PMID: 37894281 PMCID: PMC10605127 DOI: 10.3390/cancers15204914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/02/2023] [Accepted: 10/04/2023] [Indexed: 10/29/2023] Open
Abstract
Intensity-modulated radiotherapy (IMRT), an advanced RT technique, is a considerable treatment option for hepatocellular carcinoma (HCC). However, the distinguishing features of IMRT for HCC have not yet been clearly defined. A systematic review was performed according to the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. The PubMed/MedLine, Embase, Cochrane Library, Web of Science, and KoreaMed were used to screen eligible studies focusing on treatment outcomes after IMRT for HCC until 18 April 2023. A total of 1755 HCC patients receiving IMRT among 29 studies from 2009 to 2023 were selected for the meta-analysis. The median proportion of Barcelona Clinic Liver Cancer stage C was 100% (range: 38-100%). Nineteen studies used combined treatment. Pooled rates of response and 1-year local control were 58% (95% confidence interval [CI], 50-65%) and 84% (95% CI, 70-94%), respectively. The median overall survival (OS) was 13 months (range: 5-45 months), and pooled 1- and 3-year OS rates were 59% (95% CI, 52-66%), and 23% (95% CI, 14-33%), respectively. Pooled rates of classic radiation-induced liver disease (RILD), nonclassic RILD, and hepatic toxicity ≥ grade 3 were 2%, 4%, and 4%, respectively. Although most patients had advanced-stage HCC and combined treatment was commonly used, IMRT for HCC showed similar survival to existing RT modalities and relatively low severe toxicity.
Collapse
Affiliation(s)
- Won Il Jang
- Department of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, 75, Nowon-ro, Nowon-gu, Seoul 01812, Republic of Korea;
| | - Sunmi Jo
- Department of Radiation Oncology, Haeundae Paik Hospital, Inje University School of Medicine, 875, Haeun-daero, Haeundae-gu, Busan 48108, Republic of Korea;
| | - Ji Eun Moon
- Department of Biostatistics, Soonchunhyang University College of Medicine, Bucheon, 170 Jomaru-ro, Wongmi-gu, Bucheon-si 14584, Gyeonggi-do, Republic of Korea;
| | - Sun Hyun Bae
- Department of Radiation Oncology, Soonchunhyang University College of Medicine, Bucheon, 170 Jomaru-ro, Wongmi-gu, Bucheon-si 14584, Gyeonggi-do, Republic of Korea
| | - Hee Chul Park
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul 06351, Republic of Korea
| |
Collapse
|
7
|
Katsuta T, Murakami Y, Kawahara D, Miyoshi S, Imano N, Hirokawa J, Nishibuchi I, Nagata Y. Novel simulation for dosimetry impact of diaphragm respiratory motion in four-dimensional volumetric modulated arc therapy for esophageal cancer. Radiother Oncol 2023; 187:109849. [PMID: 37562552 DOI: 10.1016/j.radonc.2023.109849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 07/28/2023] [Accepted: 08/01/2023] [Indexed: 08/12/2023]
Abstract
BACKGROUND AND PURPOSE The diaphragm respiratory motion (RM) could impact the target dose robustness in the lower esophageal cancer (EC). We aimed to develop a framework evaluating the impact of different RM patterns quantitatively in one patient, by creating virtual four-dimensional computed-tomography (v4DCT) images, which could lead to tailored treatment for the breathing pattern. We validated virtual 4D radiotherapy (v4DRT) along with exploring the acceptability of free-breathing volumetric modulated arc therapy (FB-VMAT). METHODS AND MATERIALS We assessed 10 patients with superficial EC through their real 4DCT (r4DCT) scans. v4DCT images were derived from the end-inhalation computed tomography (CT) image (reference CT) and the v4DRT dose was accumulated dose over all phases. r4DRT diaphragm shifts were applied with magnitudes derived from r4DCT scans; clinical target volume (CTV) dose of v4DRT was compared with that of r4DRT to validate v4DRT. CTV dosage modifications and planning organ at risk volume (PRV) margins of the spinal cord were examined with the diaphragm movement. The percentage dose differences (ΔDx) were determined between the v4DRT and the dose calculated on the reference CT image. RESULTS The CTV ΔDx between the r4DRT and v4DRT were within 1% in cases with RM ≦ 15 mm. The average ΔD100% and ΔDmean of the CTV ranging from 5 to 15 mm of diaphragm motion was 0.3% to 1.7% and 0.1% to 0.4%, respectively. All CTV index changes were within 3% and ΔD1cc and ΔD2cc of Cord PRV were within 1%. CONCLUSION We postulate a novel method for evaluating the CTV robustness, comparable to the conventional r4DCT method under the diaphragm RM ≦ 15 mm permitting an impact of within 3% in FB-VMAT for EC on the CTV dose distribution.
Collapse
Affiliation(s)
- Tsuyoshi Katsuta
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yuji Murakami
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.
| | - Daisuke Kawahara
- Section of Radiation Therapy, Department of Clinical Practice and Support, Hiroshima University Hospital, Hiroshima 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Shota Miyoshi
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Nobuki Imano
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Junichi Hirokawa
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Ikuno Nishibuchi
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| | - Yasushi Nagata
- Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
8
|
Krishnapriya P, Sivanandan CD, Roshni S, Sarin B, Geethi MH, Jagathnath Krishna KM. Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus. J Cancer Res Ther 2023; 19:1844-1851. [PMID: 38376288 DOI: 10.4103/jcrt.jcrt_1664_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 02/09/2022] [Indexed: 02/21/2024]
Abstract
BACKGROUND Radical chemoradiation is the standard of treatment for locally advanced squamous cell carcinoma of esophagus and for patients with operable disease, but who are medically unfit or unwilling for surgery. As the esophagus is a central organ, the planning target volume (PTV) is central, lies close to the spinal cord and heart, and is surrounded by the lung, which is a radiosensitive organ. Irradiation of these critical structures is reduced by the use of three-dimensional conformal radiation therapy (3DCRT). Intensity-modulated radiation therapy (IMRT) has the potential to improve the uniformity of dose distribution to the tumor and reduce the dose received by surrounding normal tissues. AIM AND OBJECTIVES 1. To compare the dose distribution, conformity, and homogeneity indices in radical radiotherapy of squamous cell carcinoma of esophagus using 3DCRT and IMRT techniques 2. To compare the doses received by critical structures such as heart, lung, spinal cord, and liver. MATERIALS AND METHODS All cases of squamous cell carcinoma esophagus treated with radical chemoradiation to a dose of 50 Gy in 25 fractions using 3DCRT technique from January 2018 to July 2019 were included. IMRT plans were generated for these cases.The parameters that represent dose distribution to the target volume and the dose received by the organs at risk were obtained from the dose-volume histogram. The difference in the mean values of the parameters between the two techniques was calculated. The statistical significance of the difference was determined using Student's t-test and Wilcoxon signed-rank test. RESULTS The volume of PTV receiving 105% and 107% of prescribed dose was significantly lower with IMRT (3.540% and 0.008%, respectively) compared to 3DCRT (7.654% and 0.623%). The homogeneity index was better with IMRT (0.088 vs. 0.107) than 3DCRT. Conformity index was found to be better with IMRT (1.149 vs. 1.573). Mean heart dose (18.216 vs. 24.591 Gy) and the volume of heart receiving 30 Gy were reduced with IMRT. The volume of lung receiving 20 Gy and the volume receiving 5 Gy were not significantly different between 3DCRT and IMRT. Maximum dose to spinal cord was similar with 3DCRT and IMRT. CONCLUSIONS IMRT avoids areas of excessive irradiation within the PTV. IMRT improves dose conformity to the target volume and homogeneity of dose distribution within the PTV. The cardiac dose is significantly reduced with IMRT. The mean lung dose remains similar to 3DCRT. There is no significant increase in the volume of lung receiving low-dose radiation with IMRT.
Collapse
Affiliation(s)
- P Krishnapriya
- Department of Radiation Oncology, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - C D Sivanandan
- Department of Radiation Oncology, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - S Roshni
- Department of Radiation Oncology, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - B Sarin
- Department of Radiation Physics, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - M H Geethi
- Department of Radiation Oncology, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| | - K M Jagathnath Krishna
- Department of Epidemiology and Biostatistics, Regional Cancer Centre, Thiruvananthapuram, Kerala, India
| |
Collapse
|
9
|
Ansinelli H, Gay C, Nguyen S, Morrison CM, Robbins JR. Personalized precision radiotherapy and its evolving role for human papillomavirus-positive oropharyngeal cancer. JOURNAL OF THE NATIONAL CANCER CENTER 2023; 3:72-82. [PMID: 39036313 PMCID: PMC11256722 DOI: 10.1016/j.jncc.2022.11.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/19/2022] [Accepted: 11/30/2022] [Indexed: 12/31/2022] Open
Abstract
Human papilloma virus (HPV)-associated oropharyngeal cancer (OPC) is a unique entity with increased responsiveness to treatment and excellent oncologic outcomes. The purpose of this narrative review is to highlight how an improved prognosis for HPV (+) tumors and an ever-increasing understanding of the risk factors, risk stratification, and areas of potential spread are shaping management options. Additionally, we aim to detail how advances in treatment technology on both the surgical and radiation fronts are facilitating the delivery of increasingly personalized and precise treatments. This review will describe key aspects of recent and currently-ongoing trials investigating the de-escalation and individualization of treatment in this patient cohort, and how they are building a foundation for distinct treatment paradigms for HPV (+) tumors. Further studies into the integration of biomarker-guided treatments combined with clinical trial enrollment will help ensure a future of personalized treatments and improved outcomes, both in terms of oncologic outcomes and toxicity, for patients with HPV (+) OPC.
Collapse
Affiliation(s)
- Hayden Ansinelli
- University of Arizona College of Medicine, Department of Radiation Oncology, Tucson, United States
| | - Chris Gay
- University of Arizona College of Medicine, Department of Radiation Oncology, Tucson, United States
| | - Steven Nguyen
- University of Arizona College of Medicine, Department of Radiation Oncology, Tucson, United States
| | - Christopher M. Morrison
- University of Arizona College of Medicine, Department of Radiation Oncology, Tucson, United States
| | - Jared R. Robbins
- University of Arizona College of Medicine, Department of Radiation Oncology, Tucson, United States
| |
Collapse
|
10
|
Dei D, Lambri N, Stefanini S, Vernier V, Brioso RC, Crespi L, Clerici E, Bellu L, De Philippis C, Loiacono D, Navarria P, Reggiori G, Bramanti S, Rodari M, Tomatis S, Chiti A, Carlo-Stella C, Scorsetti M, Mancosu P. Internal Guidelines for Reducing Lymph Node Contour Variability in Total Marrow and Lymph Node Irradiation. Cancers (Basel) 2023; 15:1536. [PMID: 36900326 PMCID: PMC10000500 DOI: 10.3390/cancers15051536] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 02/21/2023] [Accepted: 02/24/2023] [Indexed: 03/05/2023] Open
Abstract
BACKGROUND The total marrow and lymph node irradiation (TMLI) target includes the bones, spleen, and lymph node chains, with the latter being the most challenging structures to contour. We evaluated the impact of introducing internal contour guidelines to reduce the inter- and intraobserver lymph node delineation variability in TMLI treatments. METHODS A total of 10 patients were randomly selected from our database of 104 TMLI patients so as to evaluate the guidelines' efficacy. The lymph node clinical target volume (CTV_LN) was recontoured according to the guidelines (CTV_LN_GL_RO1) and compared to the historical guidelines (CTV_LN_Old). Both topological (i.e., Dice similarity coefficient (DSC)) and dosimetric (i.e., V95 (the volume receiving 95% of the prescription dose) metrics were calculated for all paired contours. RESULTS The mean DSCs were 0.82 ± 0.09, 0.97 ± 0.01, and 0.98 ± 0.02, respectively, for CTV_LN_Old vs. CTV_LN_GL_RO1, and between the inter- and intraobserver contours following the guidelines. Correspondingly, the mean CTV_LN-V95 dose differences were 4.8 ± 4.7%, 0.03 ± 0.5%, and 0.1 ± 0.1%. CONCLUSIONS The guidelines reduced the CTV_LN contour variability. The high target coverage agreement revealed that historical CTV-to-planning-target-volume margins were safe, even if a relatively low DSC was observed.
Collapse
Affiliation(s)
- Damiano Dei
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Nicola Lambri
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Sara Stefanini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Veronica Vernier
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Ricardo Coimbra Brioso
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milan, Italy
| | - Leonardo Crespi
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milan, Italy
- Health Data Science Centre, Human Technopole, 20157 Milan, Italy
| | - Elena Clerici
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Luisa Bellu
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Chiara De Philippis
- Department of Oncology and Hematology, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Daniele Loiacono
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milan, Italy
| | - Pierina Navarria
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Giacomo Reggiori
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Stefania Bramanti
- Department of Oncology and Hematology, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Marcello Rodari
- Department of Nuclear Medicine, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Stefano Tomatis
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Arturo Chiti
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Nuclear Medicine, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Carmelo Carlo-Stella
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Oncology and Hematology, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Marta Scorsetti
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| | - Pietro Mancosu
- Department of Radiotherapy and Radiosurgery, IRCCS Humanitas Research Hospital, via Manzoni 56, Rozzano, 20089 Milan, Italy
| |
Collapse
|
11
|
Wang H, Bai X, Wang Y, Lu Y, Wang B. An integrated solution of deep reinforcement learning for automatic IMRT treatment planning in non-small-cell lung cancer. Front Oncol 2023; 13:1124458. [PMID: 36816929 PMCID: PMC9936236 DOI: 10.3389/fonc.2023.1124458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 01/20/2023] [Indexed: 02/05/2023] Open
Abstract
Purpose To develop and evaluate an integrated solution for automatic intensity-modulated radiation therapy (IMRT) planning in non-small-cell lung cancer (NSCLC) cases. Methods A novel algorithm named as multi-objectives adjustment policy network (MOAPN) was proposed and trained to learn how to adjust multiple optimization objectives in commercial Eclipse treatment planning system (TPS), based on the multi-agent deep reinforcement learning (DRL) scheme. Furthermore, a three-dimensional (3D) dose prediction module was developed to generate the patient-specific initial optimization objectives to reduce the overall exploration space during MOAPN training. 114 previously treated NSCLC cases suitable for stereotactic body radiotherapy (SBRT) were selected from the clinical database. 87 cases were used for the model training, and the remaining 27 cases for evaluating the feasibility and effectiveness of MOAPN in automatic treatment planning. Results For all tested cases, the average number of adjustment steps was 21 ± 5.9 (mean ± 1 standard deviation). Compared with the MOAPN initial plans, the actual dose of chest wall, spinal cord, heart, lung (affected side), esophagus and bronchus in the MOAPN final plans reduced by 14.5%, 11.6%, 4.7%, 16.7%, 1.6% and 7.7%, respectively. The dose result of OARs in the MOAPN final plans was similar to those in the clinical plans. The complete automatic treatment plan for a new case was generated based on the integrated solution, with about 5-6 min. Conclusion We successfully developed an integrated solution for automatic treatment planning. Using the 3D dose prediction module to obtain the patient-specific optimization objectives, MOAPN formed action-value policy can simultaneously adjust multiple objectives to obtain a high-quality plan in a shorter time. This integrated solution contributes to improving the efficiency of the overall planning workflow and reducing the variation of plan quality in different regions and treatment centers. Although improvement is warranted, this proof-of-concept study has demonstrated the feasibility of this integrated solution in automatic treatment planning based on the Eclipse TPS.
Collapse
|
12
|
Ng J, Gregucci F, Pennell RT, Nagar H, Golden EB, Knisely JPS, Sanfilippo NJ, Formenti SC. MRI-LINAC: A transformative technology in radiation oncology. Front Oncol 2023; 13:1117874. [PMID: 36776309 PMCID: PMC9911688 DOI: 10.3389/fonc.2023.1117874] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/16/2023] [Indexed: 01/28/2023] Open
Abstract
Advances in radiotherapy technologies have enabled more precise target guidance, improved treatment verification, and greater control and versatility in radiation delivery. Amongst the recent novel technologies, Magnetic Resonance Imaging (MRI) guided radiotherapy (MRgRT) may hold the greatest potential to improve the therapeutic gains of image-guided delivery of radiation dose. The ability of the MRI linear accelerator (LINAC) to image tumors and organs with on-table MRI, to manage organ motion and dose delivery in real-time, and to adapt the radiotherapy plan on the day of treatment while the patient is on the table are major advances relative to current conventional radiation treatments. These advanced techniques demand efficient coordination and communication between members of the treatment team. MRgRT could fundamentally transform the radiotherapy delivery process within radiation oncology centers through the reorganization of the patient and treatment team workflow process. However, the MRgRT technology currently is limited by accessibility due to the cost of capital investment and the time and personnel allocation needed for each fractional treatment and the unclear clinical benefit compared to conventional radiotherapy platforms. As the technology evolves and becomes more widely available, we present the case that MRgRT has the potential to become a widely utilized treatment platform and transform the radiation oncology treatment process just as earlier disruptive radiation therapy technologies have done.
Collapse
Affiliation(s)
- John Ng
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States,*Correspondence: John Ng,
| | - Fabiana Gregucci
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States,Department of Radiation Oncology, Miulli General Regional Hospital, Acquaviva delle Fonti, Bari, Italy
| | - Ryan T. Pennell
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | - Himanshu Nagar
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | - Encouse B. Golden
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| | | | | | - Silvia C. Formenti
- Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States
| |
Collapse
|
13
|
Sasaki M, Nakaguchi Y, Kamomae T, Ueda S, Endo Y, Sato D, Ikushima H. Predicting the complexity of head-and-neck volumetric-modulated arc therapy planning using a radiation therapy planning quality assurance software. Rep Pract Oncol Radiother 2022; 27:963-972. [PMID: 36632304 PMCID: PMC9826646 DOI: 10.5603/rpor.a2022.0122] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 11/18/2022] [Indexed: 12/31/2022] Open
Abstract
Background/Aim The more complex the treatment plan, the higher the possibility of errors in dose verification. Recently, a treatment planning quality assurance (QA) software (PlanIQ) with a function to objectively evaluate the quality of volumetric-modulated arc therapy (VMAT) treatment plans by scoring and calculating the ideal dose-volume histogram has been marketed. This study aimed to assess the association between the scores of ideal treatment plans identified using PlanIQ and the results of dose verification and to investigate whether the results of dose verification can be predicted based on the complexity of treatment plans. Materials and methods Dose verification was performed using an ionization chamber dosimeter, a radiochromic film, and a three-dimensional dose verification system, Delta4 PT. Correlations between the ideal treatment plan scores obtained by PlanIQ and the results of the absolute dose verification and dose distribution verification were obtained, and it was examined whether dose verifications could be predicted from the complexity of the treatment plans. Results Even when the score from the ideal treatment plan was high, the results of absolute dose verification and dose distribution verification were sometimes poor. However, even when the score from the ideal treatment plan was low, the absolute volume verification and dose distribution verification sometimes yielded good results. Conclusions Treatment plan complexity can be determined in advance from the ideal treatment plan score calculated by PlanIQ. However, it is difficult to predict the results of dose verification using an ideal treatment plan.
Collapse
Affiliation(s)
- Motoharu Sasaki
- Department of Therapeutic Radiology, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
| | | | - Takeshi Kamomae
- Department of Radiology, Nagoya University Graduate School of Medicine, Aichi, Japan
| | - Shoji Ueda
- Department of Radiological Technology, Yawatahama City General Hospital, Ehime, Japan
| | - Yuto Endo
- Graduate School Medical Sciences, Tokushima University, Tokushima, Japan
| | - Daisuke Sato
- Graduate School of Health Sciences, Tokushima University, Tokushima, Japan
| | - Hitoshi Ikushima
- Department of Therapeutic Radiology, Institute of Biomedical Sciences, Tokushima University Graduate School, Tokushima, Japan
| |
Collapse
|
14
|
Kantemiris I, Pappas EP, Lymperopoulou G, Thanasas D, Karaiskos P. Monte Carlo-Based Radiobiological Investigation of the Most Optimal Ion Beam Forming SOBP for Particle Therapy. J Pers Med 2022; 13:jpm13010023. [PMID: 36675684 PMCID: PMC9864401 DOI: 10.3390/jpm13010023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 12/13/2022] [Accepted: 12/21/2022] [Indexed: 12/25/2022] Open
Abstract
Proton (p) and carbon (C) ion beams are in clinical use for cancer treatment, although other particles such as He, Be, and B ions have more recently gained attention. Identification of the most optimal ion beam for radiotherapy is a challenging task involving, among others, radiobiological characterization of a beam, which is depth-, energy-, and cell type- dependent. This study uses the FLUKA and MCDS Monte Carlo codes in order to estimate the relative biological effectiveness (RBE) for several ions of potential clinical interest such as p, 4He, 7Li, 10Be, 10B, and 12C forming a spread-out Bragg peak (SOBP). More specifically, an energy spectrum of the projectiles corresponding to a 5-cm SOBP at a depth of 8 cm was used. All secondary particles produced by the projectiles were considered and RBE was determined based on radiation-induced Double Strand Breaks (DSBs), as calculated by MCDS. In an attempt to identify the most optimal ion beam, using the latter data, biological optimization was performed and the obtained depth-dose distributions were inter-compared. The results showed that 12C ions are more effective inside the SOBP region, which comes at the expense of higher dose values at the tail (i.e., after the SOBP). In contrast, p beams exhibit a higher DSOPB/DEntrance ratio, if physical doses are considered. By performing a biological optimization in order to obtain a homogeneous biological dose (i.e., dose × RBE) in the SOBP, the corresponding advantages of p and 12C ions are moderated. 7Li ions conveniently combine a considerably lower dose tail and a DSOPB/DEntrance ratio similar to 12C. This work contributes towards identification of the most optimal ion beam for cancer therapy. The overall results of this work suggest that 7Li ions are of potential interest, although more studies are needed to demonstrate the relevant advantages. Future work will focus on studying more complex beam configurations.
Collapse
Affiliation(s)
- Ioannis Kantemiris
- Medical Physics Department, Metropolitan Hospital, 18547 Neo Faliro, Greece
| | - Eleftherios P. Pappas
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Georgia Lymperopoulou
- 1st Department of Radiology, Medical School, National and Kapodistrian University of Athens, 11528 Athens, Greece
| | - Dimitrios Thanasas
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
| | - Pantelis Karaiskos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 11527 Athens, Greece
- Correspondence:
| |
Collapse
|
15
|
Gurusamy VM, Al-Hammadi N, Caparrotti P, Divakar SR, Hammoud RW, Shaikh G. Real-world clinical outcomes with daily image-guided IMRT in extremity soft tissue sarcomas. Cancer Treat Res Commun 2022; 33:100655. [PMID: 36356354 DOI: 10.1016/j.ctarc.2022.100655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/24/2022] [Accepted: 10/25/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE We report the clinical outcomes of patients with soft tissue sarcomas (STS) arising in extremities treated with image-guided intensity modulated radiotherapy (IG-IMRT) at our institute. Local control of the tumors treated with RT was the primary end point of this study. Analyzing overall survival and long-term toxicities were the secondary objectives. METHODS AND MATERIALS The database of the patients with STS who received wide local excision and IG-IMRT at our institution from January 2012 to December 2020 was reviewed. Radiation was offered either preoperatively or postoperatively as part of multi-modality treatment. RESULTS Thirty-three consecutive patients were identified and included for analysis. Twenty-eight patients (84.8%) received postoperative adjuvant radiotherapy. Dedicated MRI simulation studies were performed in 31 patients (93.9%) in the treatment position. RapidArc IMRT technique was used in 31 patients (93.9%). A total of 2954 images were acquired during 991 treatment sessions. Errors exceeding 1 mm in the x, y and z directions were corrected online before the treatment. With a median follow-up of 36 months, two patients (6.1%) developed local recurrence. The 3-year local control was 90.9% (95% CI, 0.76 - 0.98), and the 5-year overall survival was 71.7% (95% CI, 0.44 - 0.88). One patient (3.03%) sustained a pathological fracture during the follow-up period. CONCLUSION Our results showed that IMRT with daily imaging offered excellent local control with acceptable long-term toxicity, as well as being feasible and practical to implement in our routine clinical practice.
Collapse
Affiliation(s)
- Venkada Manickam Gurusamy
- Department of Radiation Oncology, National Center for Cancer Care and Research (NCCCR), Hamad Medical Corporation, Doha, Qatar.
| | - Noora Al-Hammadi
- Department of Radiation Oncology, National Center for Cancer Care and Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Palmira Caparrotti
- Department of Radiation Oncology, National Center for Cancer Care and Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Saju Raveendran Divakar
- Department of Radiation Oncology, National Center for Cancer Care and Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Rabih Wafiq Hammoud
- Department of Radiation Oncology, National Center for Cancer Care and Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| | - Ghazia Shaikh
- Department of Radiation Oncology, National Center for Cancer Care and Research (NCCCR), Hamad Medical Corporation, Doha, Qatar
| |
Collapse
|
16
|
Yin X, You L, Hu X. Role of Radiation Therapy in Mortality among Adolescents and Young Adults with Lymphoma: Differences According to Cause of Death. Cancers (Basel) 2022; 14:cancers14205067. [PMID: 36291852 PMCID: PMC9599966 DOI: 10.3390/cancers14205067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 10/05/2022] [Accepted: 10/14/2022] [Indexed: 11/16/2022] Open
Abstract
Simple Summary Despite its efficacy, emerging concerns exist regarding radiation therapy (RT)-associated toxicity in adolescent and young adult (AYA) lymphoma patients. However, the most current research studying the association between RT and outcome is based only on groups of lymphoma patients and is not compared with the general population, which could more accurately reveal the impact of RT on outcomes. This population-based analysis showed that after adjusting for potential confounders, RT administration is associated with a low risk of cause-specific mortality, including death due to the original diagnosis, second malignant neoplasms (SMNs), and noncancer causes, among AYA patients with lymphoma. This analysis may play a guiding role in the design of future lymphoma studies and the formulation of healthcare policies regarding the widespread use of RT, especially for AYA survivors. Abstract Background: Despite its efficacy, emerging concerns exist regarding radiation therapy (RT)-associated toxicity in adolescent and young adult (AYA) lymphoma patients. Few long-term follow-up studies have examined the association between RT and outcomes. Methods: Lymphoma patients aged 15–39 years were identified in the Surveillance, Epidemiology and End Results (SEER) database from 1992 to 2016. Mortality was assessed by comparing those with and without RT using the Fine–Gray competing risk model. Standardized mortality ratios (SMRs) were used to assess the relative risk of death compared with the general U.S. population. Results: In total, 29,686 patients were included; 10,708 (36.07%) received RT. Cause-specific mortality was compared between patients with and without RT while considering other competing events, including death due to index cancer, second malignant neoplasms (SMNs), and noncancer causes. Patients with RT had a lower probability of death and crude 5-year cumulative incidence of death. Moreover, there were significantly lower SMRs in patients with RT than in patients without RT. Differences between the two groups were greatest for mortality due to hematological malignancies and infections. Additionally, in the RT cohort, the SMR for index-cancer-related death was highest in the first year after diagnosis and gradually decreased. Hematological malignancies and infections were the most common specific SMN and noncancer causes of death, respectively. Conclusions: RT did not increase mortality from index cancer, SMNs, or noncancer causes in AYA patients with lymphoid malignancies. The current analysis may serve as a reference for healthcare providers monitoring RT application for AYA lymphoid malignancy survivors.
Collapse
Affiliation(s)
- Xuejiao Yin
- Department of Hematology, The First Affiliated Hospital, Zhejiang University School of Medicine, #79 Qingchun Road, Hangzhou 310003, China
- Zhejiang Province Key Laboratory of Hematology Oncology Diagnosis and Treatment, Hangzhou 310003, China
| | - Liangshun You
- Department of Hematology, The First Affiliated Hospital, Zhejiang University School of Medicine, #79 Qingchun Road, Hangzhou 310003, China
- Zhejiang Province Key Laboratory of Hematology Oncology Diagnosis and Treatment, Hangzhou 310003, China
- Correspondence: (L.Y.); (X.H.); Tel./Fax: +86-571-87236702 (L.Y. & X.H.)
| | - Xuelian Hu
- Department of Hematology, The First Affiliated Hospital, Zhejiang University School of Medicine, #79 Qingchun Road, Hangzhou 310003, China
- Zhejiang Province Key Laboratory of Hematology Oncology Diagnosis and Treatment, Hangzhou 310003, China
- Correspondence: (L.Y.); (X.H.); Tel./Fax: +86-571-87236702 (L.Y. & X.H.)
| |
Collapse
|
17
|
Krauleidis A, Adliene D, Rutkuniene Z. The Impact of Temporal Changes in Irradiated nMAG Polymer Gels on Their Applicability in Small Field Dosimetry in Radiotherapy. Gels 2022; 8:629. [PMID: 36286130 PMCID: PMC9601347 DOI: 10.3390/gels8100629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/26/2022] [Accepted: 09/27/2022] [Indexed: 11/16/2022] Open
Abstract
As advanced radiotherapy techniques progress to deliver a high absorbed dose to the target volume while minimizing the dose to normal tissues using intensity-modulated beams, arcs or stereotactic radiosurgery, new challenges occur to assure that the high treatment dose is delivered homogeneously to the tumor. Small irradiation field sizes (≤1 cm2) that tightly conform to precise target regions and allow for the deliverance of doses with a high therapeutic ratio, are of particular interest. However, the small field dosimetry using conventional dosimeters is limited by the relative large size of the detector. Radiation-sensitive polymer gels have the potential to meet this dosimetry challenge due to their almost unlimited ability in resolving three-dimensional dose distributions of any shape and makes them unique and suitable for the evaluation of dose profiles and the verification of complex doses. In this work, dose distributions in nMAG gels that have been irradiated to different doses by applying a 6 MV FFF photon beam collimated to 1 cm2, were analyzed and the dose profiles were evaluated by applying a gamma passing rate criteria of 3%/3 mm and considering different post-irradiation time intervals between the irradiation and the gels read out process. X-ray CT and NMR imaging procedures were used for the dose evaluation. It was found that the shape and uniformity of the dose profiles were changing due to post-irradiation polymerization and gelation processes, indicating time dependent growing uniformity which was better expressed for the higher delivered doses. It was estimated that in order to obtain acceptably symmetric small field dose profiles, a longer post-irradiation time is needed for getting the full scope of the polymerization as compared with the recently recommended 24 h period between irradiation and the read out processes of the dose gels. An estimated overall uncertainty (double standard deviation, 95% confidence level) of 3.66% was achieved by applying R2 measurements (NMR read out), and a 3.81-applying X-ray CT read out for 12 Gy irradiated gels 56 h post-irradiation. An increasing tendency for the uncertainty was observed with a decreasing post-irradiation time. A gamma passing rate of 90.3% was estimated for the 12 Gy irradiated gels and, 56 h post-irradiation, the X-ray CT evaluated gels as well as a gamma passing rate of 92.7% was obtained for the NMR evaluated gels applying a 3%/3 mm passing criteria.
Collapse
Affiliation(s)
| | - Diana Adliene
- Physics Department, Kaunas University of Technology, Studentu Str. 50, 51368 Kaunas, Lithuania
| | | |
Collapse
|
18
|
Addo DA, Kaufmann EE, Tagoe SN, Kyere AK. Characterization of GafChromic EBT2 film dose measurements using a tissue-equivalent water phantom for a Theratron® Equinox Cobalt-60 teletherapy machine. PLoS One 2022; 17:e0271000. [PMID: 35984784 PMCID: PMC9390906 DOI: 10.1371/journal.pone.0271000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 06/21/2022] [Indexed: 11/19/2022] Open
Abstract
PURPOSE In vivo dosimetry is a quality assurance tool that provides post-treatment measurement of the absorbed dose as delivered to the patient. This dosimetry compares the prescribed and measured dose delivered to the target volume. In this study, a tissue-equivalent water phantom provided the simulation of the human environment. The skin and entrance doses were measured using GafChromic EBT2 film for a Theratron® Equinox Cobalt-60 teletherapy machine. METHODS We examined the behaviors of unencapsulated films and custom-made film encapsulation. Films were cut to 1 cm × 1 cm, calibrated, and used to assess skin dose depositions and entrance dose. We examined the response of the film for variations in field size, source to skin distance (SSD), gantry angle and wedge angle. RESULTS The estimated uncertainty in EBT2 film for absorbed dose measurement in phantom was ±1.72%. Comparison of the measurements of the two film configurations for the various irradiation parameters were field size (p = 0.0193, α = 0.05, n = 11), gantry angle (p = 0.0018, α = 0.05, n = 24), SSD (p = 0.1802, α = 0.05, n = 11) and wedge angle (p = 0.6834, α = 0.05, n = 4). For a prescribed dose of 200 cGy and at reference conditions (open field 10 cm x 10 cm, SSD = 100 cm, and gantry angle = 0º), the measured skin dose using the encapsulation material was 70% while that measured with the unencapsulated film was 24%. At reference irradiation conditions, the measured skin dose using the unencapsulated film was higher for open field configurations (24%) than wedged field configurations (19%). Estimation of the entrance dose using the unencapsulated film was within 3% of the prescribed dose. CONCLUSIONS GafChromic EBT2 film measurements were significantly affected at larger field sizes and gantry angles. Furthermore, we determined a high accuracy in entrance dose estimations using the film.
Collapse
Affiliation(s)
- Daniel Akwei Addo
- Department of Computer Engineering, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana
| | - Elsie Effah Kaufmann
- Department of Biomedical Engineering, School of Engineering Sciences, University of Ghana, Legon, Accra, Ghana
| | - Samuel Nii Tagoe
- National Radiotherapy Oncology and Nuclear Medicine Centre, Korle-Bu, Accra, Ghana
- School of Biomedical and Allied health Sciences, University of Ghana, Accra, Ghana
| | - Augustine Kwame Kyere
- Medical Physics Department, Graduate School of Nuclear and Allied Sciences, University of Ghana, Atomic, Accra, Ghana
| |
Collapse
|
19
|
Sprouts D, Gao Y, Wang C, Jia X, Shen C, Chi Y. The development of a deep reinforcement learning network for dose-volume-constrained treatment planning in prostate cancer intensity modulated radiotherapy. Biomed Phys Eng Express 2022; 8. [PMID: 35523130 DOI: 10.1088/2057-1976/ac6d82] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 05/06/2022] [Indexed: 11/11/2022]
Abstract
Although commercial treatment planning systems (TPSs) can automatically solve the optimization problem for treatment planning, human planners need to define and adjust the planning objectives/constraints to obtain clinically acceptable plans. Such a process is labor-intensive and time-consuming. In this work, we show an end-to-end study to train a deep reinforcement learning (DRL) based virtual treatment planner (VTP) that can behave like a human to operate a dose-volume constrained treatment plan optimization engine following the parameters used in Eclipse TPS for high-quality treatment planning. We considered the prostate cancer IMRT treatment plan as the testbed. The VTP took the dose-volume histogram (DVH) of a plan as input and predicted the optimal strategy for constraint adjustment to improve the plan quality. The training of VTP followed the state-of-the-art Q-learning framework. Experience replay was implemented with epsilon-greedy search to explore the impacts of taking different actions on a large number of automatically generated plans, from which an optimal policy can be learned. Since a major computational cost in training was to solve the plan optimization problem repeatedly, we implemented a graphical processing unit (GPU)-based technique to improve the efficiency by 2-fold. Upon the completion of training, the established VTP was deployed to plan for an independent set of 50 testing patient cases. Connecting the established VTP with the Eclipse workstation via the application programming interface, we tested the performance the VTP in operating Eclipse TPS for automatic treatment planning with another two independent patient cases. Like a human planner, VTP kept adjusting the planning objectives/constraints to improve plan quality until the plan was acceptable or the maximum number of adjustment steps was reached under both scenarios. The generated plans were evaluated using the ProKnow scoring system. The mean plan score (± standard deviation) of the 50 testing cases were improved from 6.18 ± 1.75 to 8.14 ± 1.27 by the VTP, with 9 being the maximal score. As for the two cases under Eclipse dose optimization, the plan scores were improved from 8 to 8.4 and 8.7 respectively by the VTP. These results indicated that the proposed DRL-based VTP was able to operate the in-house dose-volume constrained TPS and Eclipse TPS to automatically generate high-quality treatment plans for prostate cancer IMRT.
Collapse
Affiliation(s)
- Damon Sprouts
- Department of Physics, The University of Texas at Arlington, Arlington, TX 76019, United States of America
| | - Yin Gao
- Innovative Technology of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75287, United States of America
| | - Chao Wang
- Innovative Technology of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75287, United States of America
| | - Xun Jia
- Innovative Technology of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75287, United States of America
| | - Chenyang Shen
- Innovative Technology of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75287, United States of America
| | - Yujie Chi
- Department of Physics, The University of Texas at Arlington, Arlington, TX 76019, United States of America
| |
Collapse
|
20
|
Gangwar VK, Gurjar OP, Kumar L, Agarwal A, Mishra VK, Prasad Mishra S, Pandey S. Dosimetric Evaluation of the Treatment Plan on Indigenous Heterogeneous Phantoms using Analytical Anisotropic Algorithm and Acuros-XB Algorithm for Different Photon Energies. J Biomed Phys Eng 2022; 12:237-244. [PMID: 35698542 PMCID: PMC9175120 DOI: 10.31661/jbpe.v0i0.2012-1246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Accepted: 05/19/2021] [Indexed: 06/15/2023]
Abstract
BACKGROUND Modern radiotherapy techniques are using advanced algorithms; however, phantoms used for quality assurance have homogeneous density; accordingly, the development of heterogeneous phantom mimicking human body sites is imperative to examine variation between planned and delivered doses. OBJECTIVE This study aimed to analyze the accuracy of planned dose by different algorithms using indigenously developed heterogeneous thoracic phantom (HT). MATERIAL AND METHODS In this experimental study, computed tomography (CT) of HT was done, and the density of different parts was measured. The plan was generated on CT images of HCP with 6 and 15 Megavoltage (MV) photon beams using different treatment techniques, including three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). Plans were delivered by the linear accelerator, and the dose was measured using the ion chamber (IC) placed in HT; planned and measured doses were compared. RESULTS Density patterns for different parts of the fabricated phantom, including rib, spine, scapula, lung, chest wall, and heart were 1.849, 1.976, 1.983, 0.173, 0.855, and 0.833 g/cc, respectively. Variation between planned and IC estimated doses with the tolerance (±5%) for all photon energies using different techniques. Acuros-XB (AXB) showed a slightly higher variation between computed and IC estimated doses using HCP compared to the analytical anisotropic algorithm (AAA). CONCLUSION The indigenous heterogeneous phantom can accurately simulate the dosimetric scenario for different algorithms (AXB or AAA) and be also utilized for routine patient-specific QA.
Collapse
Affiliation(s)
- Vinod Kumar Gangwar
- PhD Candidate, Department of Physics, M.J.P. Rohilkhand University, Bareilly Uttar Pradesh, India
| | - Om Prakash Gurjar
- PhD, Government Cancer Hospital, Mahatma Gandhi Memorial Medical College, Indore-452001, India
| | - Lalit Kumar
- PhD, Department of Applied Science & Humanities, Dr. A.P.J Abdul Kalam Technical University, Lucknow, India
- PhD, Medical Physics Division & Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
| | - Avinash Agarwal
- PhD, Department of Physics Bareilly College Bareilly, Uttar Pradesh, India
| | | | - Surendra Prasad Mishra
- PhD, Department of Radiation Oncology, Ram Manohar Lohia Medical sciences Lucknow, India
| | - Saket Pandey
- MD, Medical Physics Division amp Department of Radiation Oncology, Apollomedics Hospital, Lucknow, India
| |
Collapse
|
21
|
Dosimetric sensitivity of leaf width on volumetric modulated arc therapy plan quality: an objective approach. Rep Pract Oncol Radiother 2022; 27:76-85. [PMID: 35402026 PMCID: PMC8989436 DOI: 10.5603/rpor.a2022.0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 12/27/2021] [Indexed: 11/25/2022] Open
Abstract
Background Several authors investigated a dosimetric impact of leaf width on radiotherapy plan quality subjectively, and concluded that thinner leaf-width multileaf collimators (MLC) are beneficial because of their better coverage of clinically relevant structures. Study aimed to investigate the dosimetric effect of MLC leaf width on volumetric modulated arc therapy plan quality by objective approach. Materials and methods Twelve of each prostate and head-and-neck patients were planned for volumetric modulated arc therapy (VMAT) treatments for MLC leaf widths of 4 mm and 10 mm. Three different VMAT schemes single-arc, dual-arc and two combined independent single-arcs were optimized. Dose volume histogram and Isodose distribution were used for quantitative and qualitative comparison of the treatment plan, respectively. Dose-volume-indices of the planning target volume, organs at risk and number of delivered monitor units were compared. The 4 mm leaf width being reference over 10 mm and results were noted as statistically significant if p ≤ 0.05 using student t-test. Results All VMAT schemes for both tumor sites showed a gain in target coverage, similar organs at risk doses and higher monitor units to be delivered, when changing leaf width from 10 mm to 4 mm. The p-values were significant for majority of head-and-neck dose indices. Conclusion The thinner-leaf MLCs, owing to their better spatial resolution, result in an overall gain for target coverage, while maintaining permissible doses to the organs at risk.
Collapse
|
22
|
Han MC, Kim J, Hong CS, Chang KH, Han SC, Park K, Kim DW, Kim H, Chang JS, Kim J, Kye S, Park RH, Chung Y, Kim JS. Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases. Technol Cancer Res Treat 2022; 21:15330338221078464. [PMID: 35167403 PMCID: PMC9099354 DOI: 10.1177/15330338221078464] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Purpose: Various deformable image registration (DIR) methods have
been used to evaluate organ deformations in 4-dimensional computed tomography
(4D CT) images scanned during the respiratory motions of a patient. This study
assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients
with fiducial markers (FMs) implanted during the postoperative radiosurgery of
multiple lung metastases. Methods: To evaluate DIR algorithms, 4D
CT images of 5 patients were used, and ground-truths of FMs and tumors were
generated by physicians based on their medical expertise. The positions of FMs
and tumors in each 4D CT phase image were determined using 10 DIR algorithms,
and the deformed results were compared with ground-truth data.
Results: The target registration errors (TREs) between the FM
positions estimated by optical flow algorithms and the ground-truth ranged from
1.82 ± 1.05 to 1.98 ± 1.17 mm, which is within the uncertainty of the
ground-truth position. Two algorithm groups, namely, optical flow and demons,
were used to estimate tumor positions with TREs ranging from 1.29 ± 1.21 to
1.78 ± 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR
algorithm groups, the maximum differences of the deformed positions for gross
tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean
differences. Errors caused by the aforementioned difference in the Hounsfield
unit values were also observed. Conclusions: We quantitatively
evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the
results with ground-truth data. The optical flow algorithms showed reasonable
FM-tracking results in patient 4D CT images. The iterative optical flow method
delivered the best performance in this study. With respect to the tumor volume,
the optical flow and demons algorithms delivered the best performance.
Collapse
Affiliation(s)
- Min Cheol Han
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jihun Kim
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chae-Seon Hong
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | | | - Su Chul Han
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kwangwoo Park
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Dong Wook Kim
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hojin Kim
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jee Suk Chang
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jina Kim
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Sunsuk Kye
- 65661Yonsei Cancer Center, Seoul, Republic of Korea
| | | | | | - Jin Sung Kim
- 37991Yonsei University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
23
|
Sharma N, Gupta M, Joseph D, Gupta S, Pasricha R, Ahuja R, Krishnan AS, T S A, Raut S, Sikdar D. A Prospective Randomized Study of Intensity-Modulated Radiation Therapy Versus Three-Dimensional Conformal Radiation Therapy With Concurrent Chemotherapy in Locally Advanced Carcinoma Cervix. Cureus 2022; 14:e21000. [PMID: 35154974 PMCID: PMC8818092 DOI: 10.7759/cureus.21000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/06/2022] [Indexed: 11/05/2022] Open
Abstract
Background: External Beam Radiotherapy is the treatment of choice of locally advanced carcinoma cervix (LACC). The two techniques, three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), have been compared previously in terms of outcomes and toxicities. IMRT has still not shown any benefit over 3DCRT in terms of local control and survival. Hence, the present study was conducted to compare local control and toxicities among both techniques. Material & Methods: Fifty-four patients of LACC (FIGO IB2-IVA) were randomized to receive 50 Gray in 25 fractions by either 3DCRT or IMRT with concurrent cisplatin-based chemotherapy followed by brachytherapy. Plans were compared for planning target volume (PTV) coverage, dose to organs at risk (OAR), homogeneity index (HI), and conformity index (CI). Patients were assessed for acute toxicity and local control for three months. Results: Out of 54 patients, 27 received treatment by 3DCRT and 27 by IMRT technique. Dosimetric evaluation for PTV coverage was similar in both arms. D15, D35, and D50 (dose to 15%, 35%, and 50% volume, respectively) for bladder were significantly reduced in the IMRT arm. Dosimetry for rectum and bowel bag was similar in both. There was a significantly decreased dose to femoral heads in the IMRT arm. Patients in the 3DCRT arm had significant grade 1 and 2 anemia and neutropenia compared to the IMRT arm. Local control for three months was similar in both the arms. Conclusion: IMRT is associated with decreased acute hematological toxicity compared to 3DCRT with similar local control. Long-term follow-up is needed to assess any difference in long-term toxicity and survival between the two arms.
Collapse
|
24
|
Zhang Z, Zhang HJ. Glycometabolic rearrangements-aerobic glycolysis in pancreatic ductal adenocarcinoma (PDAC): roles, regulatory networks, and therapeutic potential. Expert Opin Ther Targets 2021; 25:1077-1093. [PMID: 34874212 DOI: 10.1080/14728222.2021.2015321] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
INTRODUCTION Glycometabolic rearrangements (aerobic glycolysis) is a hallmark of pancreatic ductal adenocarcinoma (PDAC) and contributes to tumorigenesis and progression through numerous mechanisms. The targeting of aerobic glycolysis is recognized as a potential therapeutic strategy which offers the possibility of improving treatment outcomes for PDAC patients. AREAS COVERED In this review, the role of aerobic glycolysis and its regulatory networks in PDAC are discussed. The targeting of aerobic glycolysis in PDAC is examined, and its therapeutic potential is evaluated. The relevant literature published from 2001 to 2021 was searched in databases including PubMed, Scopus, and Embase. EXPERT OPINION Regulatory networks of aerobic glycolysis in PDAC are based on key factors such as c-Myc, hypoxia-inducible factor 1α, the mammalian target of rapamycin pathway, and non-coding RNAs. Experimental evidence suggests that modulators or inhibitors of aerobic glycolysis promote therapeutic effects in preclinical tumor models. Nevertheless, successful clinical translation of drugs that target aerobic glycolysis in PDAC is an obstacle. Moreover, it is necessary to identify the potential targets for future interventions from regulatory networks to design efficacious and safer agents.
Collapse
Affiliation(s)
- Zhong Zhang
- Department of Oncology, Zhongda Hospital, Medical School of Southeast University, Nanjing, People's Republic of China
| | - Hai-Jun Zhang
- Department of Oncology, Zhongda Hospital, Medical School of Southeast University, Nanjing, People's Republic of China
| |
Collapse
|
25
|
Development of an x-ray-opaque-marker system for quantitative phantom positioning in patient-specific quality assurance. Phys Med 2021; 91:121-130. [PMID: 34785490 DOI: 10.1016/j.ejmp.2021.10.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 10/10/2021] [Accepted: 10/30/2021] [Indexed: 11/21/2022] Open
Abstract
PURPOSE We developed an x-ray-opaque-marker (XOM) system with inserted fiducial markers for patient-specific quality assurance (QA) in CyberKnife (Accuray) and a general-purpose linear accelerator (linac). The XOM system can be easily inserted or removed from the existing patient-specific QA phantom. Our study aimed to assess the utility of the XOM system by evaluating the recognition accuracy of the phantom position error and estimating the dose perturbation around a marker. METHODS The recognition accuracy of the phantom position error was evaluated by comparing the known error values of the phantom position with the values measured by matching the images with target locating system (TLS; Accuray) and on-board imager (OBI; Varian). The dose perturbation was evaluated for 6 and 10 MV single-photon beams through experimental measurements and Monte Carlo simulations. RESULTS The root mean squares (RMSs) of the residual position errors for the recognition accuracy evaluation in translations were 0.07 mm with TLS and 0.30 mm with OBI, and those in rotations were 0.13° with TLS and 0.15° with OBI. The dose perturbation was observed within 1.5 mm for 6 MV and 2.0 mm for 10 MV from the marker. CONCLUSIONS Sufficient recognition accuracy of the phantom position error was achieved using our system. It is unnecessary to consider the dose perturbation in actual patient-specific QA. We concluded that the XOM system can be utilized to ensure quantitative and accurate phantom positioning in patient-specific QA with CyberKnife and a general-purpose linac.
Collapse
|
26
|
Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109564] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
27
|
Mao W, Liu C, Gardner SJ, Elshaikh M, Aref I, Lee JK, Pradhan D, Siddiqui F, Snyder KC, Kumarasiri A, Zhao B, Kim J, Li H, Wen NW, Movsas B, Chetty IJ. How does CBCT reconstruction algorithm impact on deformably mapped targets and accumulated dose distributions? J Appl Clin Med Phys 2021; 22:37-48. [PMID: 34378308 PMCID: PMC8425863 DOI: 10.1002/acm2.13328] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 05/17/2021] [Accepted: 05/26/2021] [Indexed: 01/20/2023] Open
Abstract
PURPOSE We performed quantitative analysis of differences in deformable image registration (DIR) and deformable dose accumulation (DDA) computed on CBCT datasets reconstructed using the standard (Feldkamp-Davis-Kress: FDK_CBCT) and a novel iterative (iterative_CBCT) CBCT reconstruction algorithms. METHODS Both FDK_CBCT and iterative_CBCT images were reconstructed for 323 fractions of treatment for 10 prostate cancer patients. Planning CT images were deformably registered to each CBCT image data set. After daily dose distributions were computed, they were mapped to planning CT to obtain deformed doses. Dosimetric and image registration results based CBCT images reconstructed by two algorithms were compared at three levels: (A) voxel doses over entire dose calculation volume, (B) clinical constraint results on targets and sensitive structures, and (C) contours propagated to CBCT images using DIR results based on three algorithms (SmartAdapt, Velocity, and Elastix) were compared with manually delineated contours as ground truth. RESULTS (A) Average daily dose differences and average normalized DDA differences between FDK_CBCT and iterative_CBCT were ≤1 cGy. Maximum daily point dose differences increased from 0.22 ± 0.06 Gy (before the deformable dose mapping operation) to 1.33 ± 0.38 Gy after the deformable dose mapping. Maximum differences of normalized DDA per fraction were up to 0.80 Gy (0.42 ± 0.19 Gy). (B) Differences in target minimum doses were up to 8.31 Gy (-0.62 ± 4.60 Gy) and differences in critical structure doses were 0.70 ± 1.49 Gy. (C) For mapped prostate contours based on iterative_CBCT (relative to standard FDK_CBCT), dice similarity coefficient increased by 0.10 ± 0.09 (p < 0.0001), mass center distances decreased by 2.5 ± 3.0 mm (p < 0.00005), and Hausdorff distances decreased by 3.3 ± 4.4 mm (p < 0.00015). CONCLUSIONS The new iterative CBCT reconstruction algorithm leads to different mapped volumes of interest, deformed and cumulative doses than results based on conventional FDK_CBCT.
Collapse
Affiliation(s)
- Weihua Mao
- Henry Ford Health System, Detroit, MI, USA
| | - Chang Liu
- Henry Ford Health System, Detroit, MI, USA
| | | | | | | | - Joon K Lee
- Henry Ford Health System, Detroit, MI, USA
| | | | | | | | | | - Bo Zhao
- Henry Ford Health System, Detroit, MI, USA
| | - Joshua Kim
- Henry Ford Health System, Detroit, MI, USA
| | - Haisen Li
- Henry Ford Health System, Detroit, MI, USA
| | | | | | | |
Collapse
|
28
|
Nakamura K, Okuhata K, Tamura M, Otsuka M, Kubo K, Ueda Y, Nakamura Y, Nakamatsu K, Tanooka M, Monzen H, Nishimura Y. An updating approach for knowledge-based planning models to improve plan quality and variability in volumetric-modulated arc therapy for prostate cancer. J Appl Clin Med Phys 2021; 22:113-122. [PMID: 34338435 PMCID: PMC8425874 DOI: 10.1002/acm2.13353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 06/22/2021] [Accepted: 06/23/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The purpose of this study was to compare the dose-volume parameters and regression scatter plots of the iteratively improved RapidPlan (RP) models, specific knowledge-based planning (KBP) models, in volumetric-modulated arc therapy (VMAT) for prostate cancer over three periods. METHODS A RP1 model was created from 47 clinical intensity-modulated radiation therapy (IMRT)/VMAT plans. A RP2 model was created to exceed dosimetric goals which set as the mean values +1SD of the dose-volume parameters of RP1 (50 consecutive new clinical VMAT plans). A RP3 model was created with more strict dose constraints for organs at risks (OARs) than RP1 and RP2 models (50 consecutive anew clinical VMAT plans). Each RP model was validated against 30 validation plans (RP1, RP2, and RP3) that were not used for model configuration, and the dose-volume parameters were compared. The Cook's distances of regression scatterplots of each model were also evaluated. RESULTS Significant differences (p < 0.05) between RP1 and RP2 were found in Dmean (101.5% vs. 101.9%), homogeneity index (3.90 vs. 4.44), 95% isodose conformity index (1.22 vs. 1.20) for the target, V40Gy (47.3% vs. 45.7%), V60Gy (27.9% vs. 27.1%), V70Gy (16.4% vs. 15.2%), and V78Gy (0.4% vs. 0.2%) for the rectal wall, and V40Gy (43.8% vs. 41.8%) and V70Gy (21.3% vs. 20.5%) for the bladder wall, whereas only V70Gy (15.2% vs. 15.8%) of the rectal wall differed significantly between RP2 and RP3. The proportions of cases with a Cook's distance of <1.0 (RP1, RP2, and RP3 models) were 55%, 78%, and 84% for the rectal wall, and 77%, 68%, and 76% for the bladder wall, respectively. CONCLUSIONS The iteratively improved RP models, reflecting the clear dosimetric goals based on the RP feedback (dose-volume parameters) and more strict dose constraints for the OARs, generated superior dose-volume parameters and the regression scatterplots in the model converged. This approach could be used to standardize the inverse planning strategies.
Collapse
Affiliation(s)
- Kenji Nakamura
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan.,Department of Radiotherapy, Takarazuka City Hospital, Kohama, Takarazuka, Japan
| | - Katsuya Okuhata
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan
| | - Mikoto Tamura
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan
| | - Masakazu Otsuka
- Department of Radiology, Kindai University Hospital, Osakasayama, Japan
| | - Kazuki Kubo
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Chuo-ku, Japan
| | - Yasunori Nakamura
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan
| | - Kiyoshi Nakamatsu
- Department of Radiation Oncology, Faculty of Medicine, Kindai University, Osakasayama, Japan
| | - Masao Tanooka
- Department of Radiotherapy, Takarazuka City Hospital, Kohama, Takarazuka, Japan
| | - Hajime Monzen
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osakasayama, Japan
| | - Yasumasa Nishimura
- Department of Radiation Oncology, Faculty of Medicine, Kindai University, Osakasayama, Japan
| |
Collapse
|
29
|
Zhu TC, Stathakis S, Clark JR, Feng W, Georg D, Holmes SM, Kry SF, Ma CMC, Miften M, Mihailidis D, Moran JM, Papanikolaou N, Poppe B, Xiao Y. Report of AAPM Task Group 219 on independent calculation-based dose/MU verification for IMRT. Med Phys 2021; 48:e808-e829. [PMID: 34213772 DOI: 10.1002/mp.15069] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/25/2021] [Accepted: 06/21/2021] [Indexed: 11/06/2022] Open
Abstract
Independent verification of the dose per monitor unit (MU) to deliver the prescribed dose to a patient has been a mainstay of radiation oncology quality assurance (QA). We discuss the role of secondary dose/MU calculation programs as part of a comprehensive QA program. This report provides guidelines on calculation-based dose/MU verification for intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) provided by various modalities. We provide a review of various algorithms for "independent/second check" of monitor unit calculations for IMRT/VMAT. The report makes recommendations on the clinical implementation of secondary dose/MU calculation programs; on commissioning and acceptance of various commercially available secondary dose/MU calculation programs; on benchmark QA and periodic QA; and on clinically reasonable action levels for agreement of secondary dose/MU calculation programs.
Collapse
Affiliation(s)
- Timothy C Zhu
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | | | | | - Wenzheng Feng
- Department of Radiation Oncology, Columbia University, New York, NY, USA
| | - Dietmar Georg
- Department of Radiation Oncology, Medical University Vienna, Vienna, Austria
| | | | - Stephen F Kry
- IROC, UT MD Anderson Cancer Center, Houston, TX, USA
| | | | - Moyed Miften
- Department of Radiation Oncology, University of Colorado Denver, Aurora, CO, USA
| | - Dimitris Mihailidis
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Jean M Moran
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | | | - Bjorn Poppe
- Pius Hospital & Carl von Ossietzky University, Oldenburg, Germany
| | - Ying Xiao
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
30
|
Guillemin F, Berger L, Lapeyre M, Bellière-Calandry A. [Dosimetric and toxicity comparison of IMRT and 3D-CRT of non-small cell lung cancer]. Cancer Radiother 2021; 25:747-754. [PMID: 34183268 DOI: 10.1016/j.canrad.2021.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 02/25/2021] [Accepted: 03/02/2021] [Indexed: 12/25/2022]
Abstract
PURPOSE Although three-dimensional conformal radiotherapy (3D-CRT) remains the gold standard as a curative treatment for NSCLC when surgery is not possible, intensity modulated radiotherapy (IMRT) is increasingly used routinely. The purpose of this study was to assess the clinical (immediate toxicities) and dosimetric impact of IMRT compared to 3D-CRT in the treatment of locally advanced (stages IIIA to IIIC) non-small cell lung cancer (NSCLC) treated with concomitant radiochemotherapy, while IMRT in lung cancer was implemented in the radiotherapy department of the Jean-Perrin Center. PATIENTS AND METHODS Between March 2015 and October 2019, 64 patients treated with concomitant radiochemotherapy were retrospectively included. Thirty-two received 3D-CRT and 32 IMRT. The radiotherapy prescription was 66Gy in 33 fractions of 2Gy. RESULTS IMRT has improved coverage of target volumes (V95 increased by 14.81% in IMRT; P<0.001) without increasing doses to OARs and reducing dysphagia (RR=0.67; P=0.027). Low doses to the lung were not significantly increased in IMRT (pulmonary V5 increased by 7.46% in IMRT). CONCLUSION Intensity modulated radiotherapy, compared with the standard RC3D technique, improve the coverage of target volumes without increasing the dose to the OARs. It also improves the immediate tolerance of the treatment by reducing the number of dysphagia.
Collapse
Affiliation(s)
- F Guillemin
- Département de radiothérapie, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1, France.
| | - L Berger
- Département de radiothérapie, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1, France
| | - M Lapeyre
- Département de radiothérapie, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1, France
| | - A Bellière-Calandry
- Département de radiothérapie, centre Jean-Perrin, 58, rue Montalembert, BP 5026, 63011 Clermont-Ferrand cedex 1, France
| |
Collapse
|
31
|
Yu L, Zhao J, Zhang Z, Wang J, Hu W. Commissioning of and preliminary experience with a new fully integrated computed tomography linac. J Appl Clin Med Phys 2021; 22:208-223. [PMID: 34151504 PMCID: PMC8292712 DOI: 10.1002/acm2.13313] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 04/27/2021] [Accepted: 05/13/2021] [Indexed: 12/05/2022] Open
Abstract
Purpose A new medical linear accelerator (linac) platform integrated with helical computed tomography (CT), the uRT‐linac 506c, was introduced into clinical application in 2019 by United Imaging Healthcare (UIH) Co., Ltd. (Shanghai, China). It combines a Carm linac with a diagnostic‐quality 16‐slice CT imager, providing seamless workflow from simulation to treatment. The aim of this report is to assess the technical characteristics, commissioning results and preliminary experiences stemming from clinical usage. Methods The mechanical and imaging test procedures, commissioning data collection and TPS validation were summarized. CTIGRT accuracy was investigated with different loads and couch extensions. A series of end‐to‐end cases for different treatment sites and delivery techniques were tested preclinically to estimate the overall accuracy for the entire treatment scheme. The results of patient‐specific QA and machine stability during a one‐year operation are also reported. Results Gantry/couch/collimator isocentricity was measured as 0.63 mm in radius. The TPS models were in agreement with the beam commissioning data within a deviation of 2%. An overall submillimeter accuracy was demonstrated for the CT‐IGRT process under all conditions. The absolute point dose difference for all the preclinical end‐to‐end tests was within 3%, and the gamma passing rate of the 2D dose distribution measured by EBT3 film was better than 90% (3% DD, 3 mm DTA and 10% threshold). Pretreatment QA of clinical cases resulted with better than 3% point dose difference and more than 99% gamma passing rate (3% DD/2 mm DTA/10% threshold) tested with Delta4. The output of the linac was mostly within 1% of variation in a one‐year operation. Conclusion The commissioning results and clinical QA results show that the uRT‐linac 506c platform exhibits good and stable performance in mechanical and dosimetric accuracy. The integrated CT system provides an efficient workflow for image guidance with submillimeter localization precision, and will be a good starting point to proceed advanced adaptive radiotherapy.
Collapse
Affiliation(s)
- Lei Yu
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Jun Zhao
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Zhen Zhang
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Jiazhou Wang
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| | - Weigang Hu
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China.,Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China
| |
Collapse
|
32
|
Cavinato S, Felser T, Fusella M, Paiusco M, Montangero S. Optimizing radiotherapy plans for cancer treatment with Tensor Networks. Phys Med Biol 2021; 66. [PMID: 34140431 DOI: 10.1088/1361-6560/ac01f2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Accepted: 05/17/2021] [Indexed: 11/12/2022]
Abstract
We present a novel application of Tensor Network methods in cancer treatment as a potential tool to solve the dose optimization problem in radiotherapy. In particular, the intensity-modulated radiation therapy technique-that allows treating irregular and inhomogeneous tumors while reducing the radiation toxicity on healthy organs-is based on the optimization problem of the beamlets intensities that shall result in a maximal delivery of the therapy dose to cancer while avoiding the organs at risk of being damaged by the radiation. The resulting optimization problem is expressed as a cost function to be optimized. Here, we map the cost function into an Ising-like Hamiltonian, describing a system of long-range interacting qubits. Finally, we solve the dose optimization problem by finding the ground-state of the Hamiltonian using a Tree Tensor Network algorithm. In particular, we present an anatomical scenario exemplifying a prostate cancer treatment. A similar approach can be applied to future hybrid classical-quantum algorithms, paving the way for the use of quantum technologies in future medical treatments.
Collapse
Affiliation(s)
- Samuele Cavinato
- Dipartimento di Fisica e Astronomia 'G. Galilei', Università degli Studi di Padova, I-35131 Padova, Italy.,Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, I-35128 Padua, Italy
| | - Timo Felser
- Dipartimento di Fisica e Astronomia 'G. Galilei', Università degli Studi di Padova, I-35131 Padova, Italy.,INFN, Sezione di Padova, I-35131 Padova, Italy.,Theoretische Physik, Universität des Saarlandes, D-66123 Saarbrücken, Germany.,Tensor Solutions, Institute for Complex Quantum Systems, University of Ulm, D-89069 Ulm, Germany
| | - Marco Fusella
- Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, I-35128 Padua, Italy
| | - Marta Paiusco
- Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, I-35128 Padua, Italy
| | - Simone Montangero
- Dipartimento di Fisica e Astronomia 'G. Galilei', Università degli Studi di Padova, I-35131 Padova, Italy.,INFN, Sezione di Padova, I-35131 Padova, Italy.,Padua Quantum Technologies Research Center, Università degli Studi di Padova, I-35131 Padova, Italy
| |
Collapse
|
33
|
Das IJ, Francescon P, Moran JM, Ahnesjö A, Aspradakis MM, Cheng CW, Ding GX, Fenwick JD, Saiful Huq M, Oldham M, Reft CS, Sauer OA. Report of AAPM Task Group 155: Megavoltage photon beam dosimetry in small fields and non-equilibrium conditions. Med Phys 2021; 48:e886-e921. [PMID: 34101836 DOI: 10.1002/mp.15030] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/06/2021] [Accepted: 06/02/2021] [Indexed: 12/14/2022] Open
Abstract
Small-field dosimetry used in advance treatment technologies poses challenges due to loss of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and the limited choice of suitable radiation detectors. These challenges greatly influence dosimetric accuracy. Many high-profile radiation incidents have demonstrated a poor understanding of appropriate methodology for small-field dosimetry. These incidents are a cause for concern because the use of small fields in various specialized radiation treatment techniques continues to grow rapidly. Reference and relative dosimetry in small and composite fields are the subject of the International Atomic Energy Agency (IAEA) dosimetry code of practice that has been published as TRS-483 and an AAPM summary publication (IAEA TRS 483; Dosimetry of small static fields used in external beam radiotherapy: An IAEA/AAPM International Code of Practice for reference and relative dose determination, Technical Report Series No. 483; Palmans et al., Med Phys 45(11):e1123, 2018). The charge of AAPM task group 155 (TG-155) is to summarize current knowledge on small-field dosimetry and to provide recommendations of best practices for relative dose determination in small megavoltage photon beams. An overview of the issue of LCPE and the changes in photon beam perturbations with decreasing field size is provided. Recommendations are included on appropriate detector systems and measurement methodologies. Existing published data on dosimetric parameters in small photon fields (e.g., percentage depth dose, tissue phantom ratio/tissue maximum ratio, off-axis ratios, and field output factors) together with the necessary perturbation corrections for various detectors are reviewed. A discussion on errors and an uncertainty analysis in measurements is provided. The design of beam models in treatment planning systems to simulate small fields necessitates special attention on the influence of the primary beam source and collimating devices in the computation of energy fluence and dose. The general requirements for fluence and dose calculation engines suitable for modeling dose in small fields are reviewed. Implementations in commercial treatment planning systems vary widely, and the aims of this report are to provide insight for the medical physicist and guidance to developers of beams models for radiotherapy treatment planning systems.
Collapse
Affiliation(s)
- Indra J Das
- Department of Radiation Oncology, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Paolo Francescon
- Department of Radiation Oncology, Ospedale Di Vicenza, Vicenza, Italy
| | - Jean M Moran
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA
| | - Anders Ahnesjö
- Medical Radiation Sciences, Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden
| | - Maria M Aspradakis
- Institute of Radiation Oncology, Cantonal Hospital of Graubünden, Chur, Switzerland
| | - Chee-Wai Cheng
- Department of Radiation Oncology, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - George X Ding
- Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN, USA
| | - John D Fenwick
- Molecular and Clinical Cancer Medicine, Institute of Systems, Molecular and Integrative Biology, University of Liverpool, Liverpool, UK
| | - M Saiful Huq
- Department of Radiation Oncology, University of Pittsburgh, School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, PA, USA
| | - Mark Oldham
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA
| | - Chester S Reft
- Department of Radiation Oncology, University of Chicago, Chicago, IL, USA
| | - Otto A Sauer
- Department of Radiation Oncology, Klinik fur Strahlentherapie, University of Würzburg, Würzburg, Germany
| |
Collapse
|
34
|
Acurio ESR, Lizar JC, Arruda GV, Pavoni JF. Technical Note: Three-dimensional QA of simultaneous integrated boost radiotherapy treatments by a dose-volume histogram methodology and its comparison with 3D gamma results. Med Phys 2021; 48:3208-3215. [PMID: 33768577 DOI: 10.1002/mp.14859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 02/22/2021] [Accepted: 03/18/2021] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Intensity-modulated radiotherapy with simultaneous integrated boost (SIB) presents several attractive advantages to be employed in clinical practice. Its secure application demands a rigorous quality assurance (QA) procedure, ideal for three-dimensional (3D) dose distribution measurements. Thus, a gel dosimetry methodology to evaluate the dose delivery of SIB treatments is presented and compared to conventional gamma evaluation. METHODS MAGIC-f gel dosimeter with magnetic resonance images for dose reading were used following its standard procedures. Four SIB QA plans created in gel dosimeter phantoms were used. The gel measured and treatment planning system (TPS) calculated doses were compared using 3D gamma analyses (3%/3mm/15% threshold). Two structures were artificially on the TPS dose distribution expected on the phantom by converting the 1.7 and 2.0 Gy isodose levels into structures to represent the treatment. The gel and TPS dose-volume histogram (DVH) were compared based on five dose points: D95%, D90%, D50%, D10%, and D5%. RESULTS Approvals of 93%, 96%, 98%, and 92% were achieved in the 3D gamma analyses for the plans QA 1, 2, 3, and 4. In the DVH analyses, QA plan 1 measured and expected curves showed a good agreement. QA plan 2 showed deviations in the highest doses for both structures with a maximum deviation (Δmáx ) of 8.0%. QA plans 3 and 4 showed the highest dose variation between the gel and TPS in the smaller doses of the DVH (Δmáx of 7.2% and -8.9%, respectively). For QA plan 4, the curves of the 1.7 Gy structure presented a good agreement, but deviations in the smaller dose region of the DVH occurred for the 2 Gy structure (Δmáx of 7.7%). CONCLUSIONS A methodology for 3D dose evaluation of complex SIB treatments was proposed. It provided an important overview of the dose distributions. Their results significantly complemented the usual gamma analysis results.
Collapse
Affiliation(s)
| | - Jéssica Caroline Lizar
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Av. Bandeirantes 3900, Monte Alegre, Ribeirão Preto, 14040-900, São Paulo, Brazil
| | - Gustavo Viani Arruda
- Radiotherapy Department, Ribeirão Preto Medical School Hospital and Clinics, University of São Paulo, Av. Bandeirantes 3900, Monte Alegre, Ribeirão Preto, 14040-900, São Paulo, Brazil
| | - Juliana Fernandes Pavoni
- Department of Physics, Faculty of Philosophy, Sciences and Letters at Ribeirão Preto, University of São Paulo, Av. Bandeirantes 3900, Monte Alegre, Ribeirão Preto, 14040-900, São Paulo, Brazil.,Radiotherapy Department, Ribeirão Preto Medical School Hospital and Clinics, University of São Paulo, Av. Bandeirantes 3900, Monte Alegre, Ribeirão Preto, 14040-900, São Paulo, Brazil
| |
Collapse
|
35
|
Evaluation of treatment plan quality for head and neck IMRT: a multicenter study. Med Dosim 2021; 46:310-317. [PMID: 33838998 DOI: 10.1016/j.meddos.2021.03.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 01/06/2021] [Accepted: 03/05/2021] [Indexed: 11/23/2022]
Abstract
Intensity-modulated radiotherapy (IMRT) treatment planning for head and neck cancer is challenging and complex due to many organs at risk (OAR) in this region. The experience and skills of planners may result in substantial variability of treatment plan quality. This study assessed the performance of IMRT planning in Malaysia and observed plan quality variation among participating centers. The computed tomography dataset containing contoured target volumes and OAR was provided to participating centers. This is to control variations in contouring the target volumes and OARs by oncologists. The planner at each center was instructed to complete the treatment plan based on clinical practice with a given prescription, and the plan was analyzed against the planning goals provided. The quality of completed treatment plans was analyzed using the plan quality index (PQI), in which a score of 0 indicated that all dose objectives and constraints were achieved. A total of 23 plans were received from all participating centers comprising 14 VMAT, 7 IMRT, and 2 tomotherapy plans. The PQI indexes of these plans ranged from 0 to 0.65, indicating a wide variation of plan quality nationwide. Results also reported 5 out of 21 plans achieved all dose objectives and constraints showing more professional training is needed for planners in Malaysia. Understanding of treatment planning system and computational physics could also help in improving the quality of treatment plans for IMRT delivery.
Collapse
|
36
|
Iwamoto KS, Sandstrom RE, Bryan M, Liu Y, Elgart SR, Sheng K, Steinberg ML, McBride WH, Low DA. Weak Magnetic Fields Enhance the Efficacy of Radiation Therapy. Adv Radiat Oncol 2021; 6:100645. [PMID: 33748547 PMCID: PMC7966835 DOI: 10.1016/j.adro.2021.100645] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 12/02/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose The clinical efficacy of radiation therapy is mechanistically linked to ionization-induced free radicals that cause cell and tissue injury through direct and indirect mechanisms. Free radical reaction dynamics are influenced by many factors and can be manipulated by static weak magnetic fields (WMF) that perturb singlet-triplet state interconversion. Our study exploits this phenomenon to directly increase ionizing radiation (IR) dose absorption in tumors by combining WMF with radiation therapy as a new and effective method to improve treatment. Methods and Materials Coils were custom made to produce both homogeneous and gradient magnetic fields. The gradient coil enabled simultaneous in vitro assessment of free radical/reactive oxygen species reactivity across multiple field strengths from 6 to 66 G. First, increases in IR-induced free radical concentrations using oxidant-sensitive fluorescent dyes in a cell-free system were measured and verified. Next, human and murine cancer cell lines were evaluated in in vitro and in vivo models after exposure to clinically relevant doses of IR in combination with WMF. Results Cellular responses to IR and WMF were field strength and cell line dependent. WMF was able to enhance IR effects on reactive oxygen species formation, DNA double-strand break formation, cell death, and tumor growth. Conclusions We demonstrate that the external presence of a magnetic field enhances radiation-induced cancer cell injury and death in vitro and in vivo. The effect extends beyond the timeframe when free radicals are induced in the presence of radiation into the window when endogenous free radicals are produced and therefore extends the applicability of this novel adjunct to cancer therapy in the context of radiation treatment.
Collapse
Affiliation(s)
- Keisuke S Iwamoto
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | | | - Mark Bryan
- Mark Bryan & Company LLC, Arcadia, California
| | - Yue Liu
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - S Robin Elgart
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Ke Sheng
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Michael L Steinberg
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - William H McBride
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Daniel A Low
- Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, California
| |
Collapse
|
37
|
Toomeh D, Gadoue SM, Fong N, Subrahmanyam GV, Govindarajan K, Ford EC. Affordable compensator for IMRT delivery designed for low-and-middle income countries, a Monte Carlo study. Phys Med 2021; 82:211-218. [PMID: 33652204 DOI: 10.1016/j.ejmp.2021.01.078] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 11/09/2020] [Accepted: 01/29/2021] [Indexed: 10/22/2022] Open
Abstract
We propose a novel cost-effective compensator that can be used to facilitate access to IMRT in low-and-middle income countries. The compensator has the advantages of simplicity, less downtime, increased reliability and less impact on treatment quality from patient motion during treatment. Moreover, the system can be used with either a cobalt-60 unit or linear accelerator. In this Monte Carlo study, the dosimetric properties of the new compensator design have been evaluated. Results were obtained for different field sizes of cobalt teletherapy machine, and the dose was scored at 0.5 cm depth in a water phantom. The effects of compensator thickness, filling material type and shape, and field size were identified. Furthermore, the percentage depth dose and beam profiles for various field sizes and at different depths were obtained. Beam profiles show no significant signature of the beads relative to a solid compensator; in addition, they exhibit a better flatness while preserving symmetry for all field sizes. A reusable bead-based compensator appears to be feasible, and provides dose distribution similar to a solid compensator with low cost and no hazards. Our results avail the ongoing efforts to expand the reach to IMRT in low- and middle-income countries.
Collapse
Affiliation(s)
- Dolla Toomeh
- University of Washington, Department of Radiation Oncology, Seattle, WA, USA; University of Miami, Department of Radiation Oncology, Miami, FL, USA.
| | | | - Nicholas Fong
- University of Washington, Department of Radiation Oncology, Seattle, WA, USA
| | | | | | - Eric C Ford
- University of Washington, Department of Radiation Oncology, Seattle, WA, USA
| |
Collapse
|
38
|
Rashid A, Ahmad Z, Memon MA, Hashim ASM. Volumetric Modulated Arc Therapy (VMAT): A modern radiotherapy technique - A single institutional experience. Pak J Med Sci 2021; 37:355-361. [PMID: 33679913 PMCID: PMC7931288 DOI: 10.12669/pjms.37.2.2647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 09/12/2020] [Accepted: 11/29/2020] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To evaluate VMAT plans for conformity and homogeneity of radiation dose to the target in order to share our experience as a pioneering institute to use VMAT technology in Pakistan. METHODS Since December 2014 to January 2018, 530 patients of various anatomical sites were treated by VMAT technique at Neurospinal Cancer Care Institute (NCCI) Karachi Pakistan. ERGO++ planning system (Version 1.7.2) was used to develop VMAT plans with single or multiple arcs by the rotation of couch and gantry. The plans were evaluated by calculating Conformity Index (CI) and Homogeneity Index (HI) and critical organ (OARs) doses of individual tumor sites. RESULTS The average CI of various sites was 1.4 (range: 1.0-2.0) and average HI of various sites was 1.20 (range: 1.07-1.374), respective critical organ doses were adequately achieved. CONCLUSIONS VMAT treatment planning technique showed good conformal and homogeneous target coverage with sparing of organs at risk and reduced treatment delivery time. With these features, safety of VMAT technique may allow its routine clinical use, though it is still under investigation in many areas.
Collapse
Affiliation(s)
- Azhar Rashid
- Dr. Azhar Rashid, MBBS, FCPS, MSc. Clinical & Radiation Oncologist, Department of Radiation Oncology (Stereotactic Radiosurgery), Neurospinal & Cancer Care Institute (NCCI), M.A Jinnah Road, Saddar, Karachi, Pakistan
| | - Zaeem Ahmad
- Mr. Zaeem Ahmed, MSc Physics Medical Physicist, Department of Radiation Oncology (Stereotactic Radiosurgery), Neurospinal & Cancer Care Institute (NCCI), M.A Jinnah Road, Saddar, Karachi, Pakistan
| | - Muhammad Ali Memon
- Dr. Muhammad Ali Memom, MBBS, FCPS. Clinical & Radiation Oncologist, Department of Radiation Oncology (Stereotactic Radiosurgery), Neurospinal & Cancer Care Institute (NCCI), M.A Jinnah Road, Saddar, Karachi, Pakistan
| | - Abdul Sattar M Hashim
- Dr. Abdul Sattar M Hashim, MBBS, MD, PhD. Chief Neurosurgeon, Department of Stereotactic Radiosurgery/Neurosurgery, Neurospinal & Cancer Care Institute (NCCI), M.A Jinnah Road, Saddar, Karachi, Pakistan
| |
Collapse
|
39
|
Ito T, Tamura M, Monzen H, Matsumoto K, Nakamatsu K, Harada T, Fukui T. [Impact of Aperture Shape Controller on Knowledge-based VMAT Planning of Prostate Cancer]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:23-31. [PMID: 33473076 DOI: 10.6009/jjrt.2021_jsrt_77.1.23] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE Knowledge-based planning (KBP) has disadvantages of high monitor unit (MU) and complex multi-leaf collimator (MLC) motion. We investigated the optimal aperture shape controller (ASC) level for the KBP to reduce these factors in volumetric modulated arc therapy (VMAT) for prostate cancer. METHODS The KBP model was created based on 51 clinical plans (CPs) of patients who underwent the VMAT for prostate cancer. Another 10 CPs were selected randomly, and the KBPs with/without ASC, changed stepwise from very low (KBP-VL) to very high (KBP-VH), were performed with a single auto-optimization. The parameters of dose-volume histograms (DVHs) and MLC performance metrics were evaluated. We obtained the modulation complexity score for VMAT (MCSv), closed leaf score (CLS), small aperture score (SAS), leaf travel (LT), and total MU. RESULTS The ASC did not affect the DVH parameters negatively. The following comparisons of MLC performance were obtained (KBP vs. KBP-VL vs. KBP-VH, respectively): 0.25 vs. 0.27 vs. 0.30 (MCSv), 0.19 vs. 0.18 vs. 0.16 (CLS), 0.50 vs. 0.45 vs. 0.40 (SAS10 mm), 0.73 vs. 0.68 vs. 0.63 (SAS20 mm), 768.35 mm vs. 671.50 mm vs. 551.32 mm (LT), and 672.87 vs. 642.36 vs. 607.59 (MU). There were significant differences between KBP and KBP-VH for MCSv and LT (p<0.05). CONCLUSIONS The KBP using an ASC set to the very high level could reduce the complexity of MLC motion significantly more without deterioration of the DVH parameters compared with the KBP in VMAT for prostate cancer.
Collapse
Affiliation(s)
- Takaaki Ito
- Department of Radiological Technology, Kobe City Nishi-Kobe Medical Center
| | - Mikoto Tamura
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University
| | - Hajime Monzen
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University
| | - Kenji Matsumoto
- Department of Medical Physics, Graduate School of Medical Sciences, Kindai University.,Department of Radiology, Kindai University Hospital
| | - Kiyoshi Nakamatsu
- Department of Radiation Oncology, Faculty of Medicine, Kindai University
| | - Tomoko Harada
- Department of Radiological Technology, Kobe City Nishi-Kobe Medical Center
| | - Tatsuya Fukui
- Department of Radiological Technology, Kobe City Nishi-Kobe Medical Center
| |
Collapse
|
40
|
Zhang J, Lv Y, Chen F, Wang X, Zhang L, Zhang X. Doses of intensity-modulated radiotherapy and its association with cardiac disease in esophageal cancer patients. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:166. [PMID: 33569468 PMCID: PMC7867929 DOI: 10.21037/atm-21-184] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background No clear guidelines or available studies exist regarding the effects of intensity-modulated radiotherapy (IMRT) of esophageal cancer (EC) on the cardiovascular system. We therefore analyzed a wide range of cardiac vascular dosimetric parameters and clinical characteristics to assess the prognostic factors for EC patients treated with IMRT. Methods A total of 112 patients receiving IMRT at the Qianfoshan Hospital between July 2012 and May 2017 were retrospectively reviewed. The dose per fraction was 1.8-2.0 Gy, and the total dose range was 54-66 Gy. Kaplan-Meier analysis was used to estimate death due to heart disease. Univariate and multivariate logistic regression models were calculated to test for associations between patient characteristics and dose-volume histogram (DVH) parameters. A t-test and chi-squared or Fisher's exact test was used to analyze the comparisons. Results The maximum and mean doses received by the heart were 57.34±13.51 and 24.83±11.40 Gy, respectively. Among the parameters examined, which included the maximum dose received by the heart, the mean dose received by the right and left ventricle (RV and LV), and the maximum dose received by the right atrium (RA), the mean dose received by the RV predicted survival and was included in our multivariate analysis. The results indicated that patients with basic heart disease who were undergoing concurrent radiochemotherapy were more likely to have cardiac disease. Conclusions This is first study to examine the prognosis of cardiovascular vessels exposed to various radiation doses during the treatment of EC, the findings of which suggest that limiting radiation exposure may be an important measure in IMRT application. These findings of this study may provide theoretical support for prediction of radiation-induced heart disease (RIHD). Furthermore, to curb the risk of RIHD, the modality of chemotherapy also needs to be attentively monitored and managed.
Collapse
Affiliation(s)
- Jiandong Zhang
- Department of Radiation Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Yajuan Lv
- Department of Oncology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China
| | - Fangjie Chen
- Department of Oncology, Renji Hospital Affiliated with Shanghai Jiao Tong University, Shanghai, China
| | | | - Li Zhang
- Department of Oncology, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China
| | - Xiaozhi Zhang
- Department of Radiation Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| |
Collapse
|
41
|
Treatment planning for non-small cell lung tumours: VMAT versus 3DCRT a quantitative dosimetric study. JOURNAL OF RADIOTHERAPY IN PRACTICE 2020. [DOI: 10.1017/s1460396919000864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractPurpose:The dosimetric impact of volumetric modulated arc therapy (VMAT) in lung cancer compared with 3D conformal radiotherapy (3DCRT) is well known. However, this improvement is often associated with an increase in low doses. The aim of this study is to quantify these results more accurately.Methods:For each patient treated with 3DCRT, a second VMAT treatment plan was calculated. Usual dosimetric parameters such as target coverage or dose to the organs at risk were used to achieve the comparisons.Results:For planning target volume, homogeneity and conformity indices showed superiority of VMAT (respectively 0·07 and 0·87) compared to 3DCRT (0·11 and 0·57). For spinal cord planning organ at risk volume, the median maximum dose was 45·6 Gy in 3DCRT against 19·3 Gy in VMAT. Heart volume receiving at least 35 Gy (V35) decreased from 15·64% in 3DCRT to 8·28% in VMAT. Oesophagus V50 was higher in 3DCRT (25·45%) than in VMAT (14·03%). The mean lung dose was 17·9 Gy in 3DCRT versus 15·5 Gy in VMAT. Moreover, volumes receiving 5, 10 and 15 Gy were not significantly different between the two techniques when VMAT was performed with partial arcs.Conclusion:All the dosimetric parameters were improved with VMAT compared to the 3DCRT without increasing low doses when using partial arcs.
Collapse
|
42
|
Abstract
External beam radiotherapy (EBRT) has improved efficacy and safety with advancements in technology and techniques. EBRT plays an important role in management of hepatocellular carcinoma (HCC). In resectable cases, EBRT serves as a bridge to transplantation or improves local control through adjuvant radiotherapy. In unresectable patients, EBRT offers high local control rates. In metastatic settings, EBRT provides effective palliation. This review presents an overview of radiotherapy treatment modalities used for HCC, current treatment guidelines for the role of EBRT in HCC, clinical outcomes between various EBRT approaches and other locoregional treatments for HCC, and the future role of EBRT for HCC.
Collapse
Affiliation(s)
- Chien Peter Chen
- Department of Radiation Oncology, Scripps Radiation Therapy Center, 10670 John Jay Hopkins Drive, San Diego, CA 92121, USA.
| |
Collapse
|
43
|
Salfelder MEA, Kessel KA, Thiel U, Burdach S, Kampfer S, Combs SE. Prospective evaluation of multitarget treatment of pediatric patients with helical intensity-modulated radiotherapy. Strahlenther Onkol 2020; 196:1103-1115. [PMID: 32748147 PMCID: PMC7686189 DOI: 10.1007/s00066-020-01670-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 07/07/2020] [Indexed: 02/06/2023]
Abstract
Background and purpose Radiotherapy (RT) is persistently gaining significance in the treatment of pediatric tumors. However, individual features of a growing body and multifocal stages complicate this approach. Tomotherapy offers advantages in the treatment of anatomically complex tumors with low risks of side effects. Here we report on toxicity incidence and outcome of tomotherapy with a focus on multitarget RT (mtRT). Materials and methods From 2008 to 2017, 38 children diagnosed with sarcoma were treated with tomotherapy. The median age was 15 years (6–19 years). Toxicity was graded according to the Common Terminology Criteria for Adverse Events v.4.03 and classified into symptoms during RT, acutely (0–6 months) and late (>6 months) after RT, and long-term sideeffects (>24 months). Results The main histologies were Ewing sarcoma (n = 23 [61%]) and alveolar rhabdomyosarcoma (n = 5 [13%]). RT was performed with a median total dose of 54 Gy (40.5–66.0 Gy) and a single dose of 2 Gy (1.80–2.27 Gy). Twenty patients (53%) received mtRT. Median follow-up was 29.7 months (95% confidence interval 15.3–48.2 months) with a 5-year survival of 55.2% (±9.5%). The 5‑year survival rate of patients with mtRT (n = 20) was 37.1 ± 13.2%, while patients who received single-target RT (n = 18) had a 5-year survival rate of 75 ± 10.8%. Severe toxicities (grade 3 and 4) emerged in 14 patients (70%) with mtRT and 7 patients (39%) with single-target RT. Two non-hematological grade 4 toxicities occurred during RT: one mucositis and one radiodermatitis. After mtRT 5 patients had grade 3 toxicities acute and after single-target RT 4 patients. One patient had acute non-hematological grade 4 toxicities (gastritis, pericarditis, and pericardial effusion) after mtRT. Severe late effects of RT occurred in 2 patients after mtRT and in none of the single-target RT patients. No severe long-term side effects appeared. Conclusion Our results showed acceptable levels of acute and late toxicities, considering the highly advanced diseases and multimodal treatment. Hence, tomotherapy is a feasible treatment method for young patients with anatomically complex tumors or multiple targets. Especially mtRT is a promising and innovative treatment approach for pediatric sarcomas, delivering unexpectedly high survival rates for patients with multifocal Ewing sarcomas in this study, whereby the limited number of patients should invariably be considered in the interpretation. Electronic supplementary material The online version of this article (10.1007/s00066-020-01670-4) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Maria-Elena A. Salfelder
- Department of Radiation Oncology, Technical University Munich (TUM), Ismaninger Straße 22, 81675 Munich, Germany
| | - Kerstin A. Kessel
- Department of Radiation Oncology, Technical University Munich (TUM), Ismaninger Straße 22, 81675 Munich, Germany
- DKTK Partner Site Munich, Deutsches Konsortium für Translationale Krebsforschung (DKTK), Munich, Germany
- Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Ingolstädter Landstraße 1, Neuherberg, Germany
| | - Uwe Thiel
- Department of Pediatrics and Children’s Cancer Research Center, Kinderklinik München Schwabing, Technical University of Munich School for Medicine, Munich, Germany
| | - Stefan Burdach
- Department of Pediatrics and Children’s Cancer Research Center, Kinderklinik München Schwabing, Technical University of Munich School for Medicine, Munich, Germany
| | - Severin Kampfer
- Department of Radiation Oncology, Technical University Munich (TUM), Ismaninger Straße 22, 81675 Munich, Germany
| | - Stephanie E. Combs
- Department of Radiation Oncology, Technical University Munich (TUM), Ismaninger Straße 22, 81675 Munich, Germany
- DKTK Partner Site Munich, Deutsches Konsortium für Translationale Krebsforschung (DKTK), Munich, Germany
- Institute of Radiation Medicine (IRM), Helmholtz Zentrum München, Ingolstädter Landstraße 1, Neuherberg, Germany
| |
Collapse
|
44
|
Lee J, Kim TH, Kim YS, Kim M, Park JW, Kim SH, Kim HJ, Lee CG. Intensity-Modulated Radiotherapy-Based Reirradiation for Head and Neck Cancer: A Multi-institutional Study by Korean Radiation Oncology Group (KROG 1707). Cancer Res Treat 2020; 52:1031-1040. [PMID: 32632081 PMCID: PMC7577818 DOI: 10.4143/crt.2020.310] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 07/06/2020] [Indexed: 12/22/2022] Open
Abstract
Purpose The benefits of reirradiation for head and neck cancer (HNC) have not been determined. This study evaluated the efficacy of reirradiation using intensity-modulated radiotherapy (IMRT) for recurrent or second primary HNC (RSPHNC) and identified subgroups for whom reirradiation for RSPHNC is beneficial. Materials and Methods A total of 118 patients from seven Korean institutions with RSPHNC who underwent IMRT-based reirradiation between 2006 and 2015 were evaluated through retrospective review of medical records. We assessed overall survival (OS) and local control (LC) within the radiotherapy (RT) field following IMRT-based reirradiation. Additionally, the OS curve according to the recursive partitioning analysis (RPA) suggested by the Multi-Institution Reirradiation (MIRI) Collaborative was determined. Results At a median follow-up period of 18.5 months, OS at 2 years was 43.1%. In multivariate analysis, primary subsite, recurrent tumor size, interval between RT courses, and salvage surgery were associated with OS. With regard to the MIRI RPA model, the class I subgroup had a significantly higher OS than class II or III subgroups. LC at 2 years was 53.5%. Multivariate analyses revealed that both intervals between RT courses and salvage surgery were prognostic factors affecting LC. Grade 3 or more toxicity and grade 5 toxicity rates were 8.5% and 0.8%, respectively. Conclusion IMRT-based reirradiation was an effective therapeutic option for patients with RSPHNC, especially those with resectable tumors and a long interval between RT courses. Further, our patients' population validated the MIRI RPA classification by showing the difference of OS according to MIRI RPA class.
Collapse
Affiliation(s)
- Jeongshim Lee
- Department of Radiation Oncology, Inha University Hospital, Inha University College of Medicine, Incheon, Korea
| | - Tae Hyung Kim
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Korea
| | - Yeon-Sil Kim
- Department of Radiation Oncology, St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Myungsoo Kim
- Department of Radiation Oncology, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Jae Won Park
- Department of Radiation Oncology, Yeungnam University Medical Center, Yeungnam University College of Medicine, Daegu, Korea
| | - Sung Hyun Kim
- Department of Radiation Oncology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea
| | - Hyun Ju Kim
- Department of Radiation Oncology, Gachon University Gil Medical Center, Incheon, Korea
| | - Chang Geol Lee
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
45
|
Application of auto-planning in radiotherapy for breast cancer after breast-conserving surgery. Sci Rep 2020; 10:10927. [PMID: 32616839 PMCID: PMC7331687 DOI: 10.1038/s41598-020-68035-w] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Accepted: 06/02/2020] [Indexed: 12/24/2022] Open
Abstract
To evaluate the quality of planning target volume (PTV) and organs at risk (OAR) generated by the manual Pinnacle planning (manP) and Auto-Planning (AP) modules and discuss the feasibility of AP in the application of radiotherapy for patients with breast cancer. Thirty patients who underwent breast-conserving therapy were randomly selected. The Philips Pinnacle 9.10 treatment planning system was used to design the manP and AP modules for PTV and OAR distribution on the same computed tomography. A physician compared the plans in terms of dosimetric parameters and monitor units (MUs) using blind qualitative scoring. Statistical differences were evaluated using paired two-sided Wilcoxon's signed-rank test. On comparing the plans of AP and manP modules, the conformal index (P < 0.01) and D50 (P = 0.04) of PTV in the AP group was lower than those in the manP group, while D1 was higher (P = 0.03). In terms of dosimetry of OAR, ipsilateral lung V20 Gy (P < 0.01), V10 Gy (P < 0.01), V5 Gy (P < 0.05), and Dmean (P < 0.01) of the AP group were better than those of the manP group. Heart V40 Gy and Dmean of all patients with breast cancer in the AP group were lower than those in the manP group (P < 0.01). Moreover, 12 patients with left breast cancer had the same results (P < 0.01). The MU value of the intensity-modulated radiation therapy module designed using two different methods was higher in the AP group than in the manP group (P = 0.32), although there was no statistical significance. The AP module almost had an equal quality of PTV and dose distribution as the manP module, and its OAR was less irradiated.
Collapse
|
46
|
Rijken J, Crowe S, Trapp J, Kairn T. A review of stereotactic body radiotherapy for the spine. Phys Eng Sci Med 2020; 43:799-824. [DOI: 10.1007/s13246-020-00889-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Accepted: 06/11/2020] [Indexed: 12/11/2022]
|
47
|
Chavda V, Patel V, Yadav D, Shah J, Patel S, Jin JO. Therapeutics and Research Related to Glioblastoma: Advancements and Future Targets. Curr Drug Metab 2020; 21:186-198. [DOI: 10.2174/1389200221666200408083950] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 11/28/2019] [Accepted: 03/27/2020] [Indexed: 12/19/2022]
Abstract
Glioblastoma, the most common primary brain tumor, has been recognized as one of the most lethal and
fatal human tumors. It has a dismal prognosis, and survival after diagnosis is less than 15 months. Surgery and radiotherapy
are the only available treatment options at present. However, numerous approaches have been made to upgrade
in vivo and in vitro models with the primary goal of assessing abnormal molecular pathways that would be
suitable targets for novel therapeutic approaches. Novel drugs, delivery systems, and immunotherapy strategies to
establish new multimodal therapies that target the molecular pathways involved in tumor initiation and progression in
glioblastoma are being studied. The goal of this review was to describe the pathophysiology, neurodegeneration
mechanisms, signaling pathways, and future therapeutic targets associated with glioblastomas. The key features have
been detailed to provide an up-to-date summary of the advancement required in current diagnosis and therapeutics
for glioblastoma. The role of nanoparticulate system graphene quantum dots as suitable therapy for glioblastoma has
also been discussed.
Collapse
Affiliation(s)
- Vishal Chavda
- Department of Pharmacology, Nirma University, Ahmadabad, Gujarat, 382481, India
| | - Vimal Patel
- Department of Pharmaceutics, Nirma University, Ahmadabad, Gujarat, 382481, India
| | - Dhananjay Yadav
- Department of Medical Biotechnology, Yeungnam University, Gyeongsan, 712-749, Korea
| | - Jigar Shah
- Department of Pharmaceutics, Nirma University, Ahmadabad, Gujarat, 382481, India
| | - Snehal Patel
- Department of Pharmacology, Nirma University, Ahmadabad, Gujarat, 382481, India
| | - Jun-O Jin
- Department of Medical Biotechnology, Yeungnam University, Gyeongsan, 712-749, Korea
| |
Collapse
|
48
|
|
49
|
Shen C, Nguyen D, Chen L, Gonzalez Y, McBeth R, Qin N, Jiang SB, Jia X. Operating a treatment planning system using a deep-reinforcement learning-based virtual treatment planner for prostate cancer intensity-modulated radiation therapy treatment planning. Med Phys 2020; 47:2329-2336. [PMID: 32141086 PMCID: PMC7903320 DOI: 10.1002/mp.14114] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 01/21/2020] [Accepted: 02/22/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In the treatment planning process of intensity-modulated radiation therapy (IMRT), a human planner operates the treatment planning system (TPS) to adjust treatment planning parameters, for example, dose volume histogram (DVH) constraints' locations and weights, to achieve a satisfactory plan for each patient. This process is usually time-consuming, and the plan quality depends on planer's experience and available planning time. In this study, we proposed to model the behaviors of human planners in treatment planning by a deep reinforcement learning (DRL)-based virtual treatment planner network (VTPN), such that it can operate the TPS in a human-like manner for treatment planning. METHODS AND MATERIALS Using prostate cancer IMRT as an example, we established the VTPN using a deep neural network developed. We considered an in-house optimization engine with a weighted quadratic objective function. Virtual treatment planner network was designed to observe an intermediate plan DVHs and decide the action to improve the plan by changing weights and threshold dose in the objective function. We trained the VTPN in an end-to-end DRL process in 10 patient cases. A plan score was used to measure plan quality. We demonstrated the feasibility and effectiveness of the trained VTPN in another 64 patient cases. RESULTS Virtual treatment planner network was trained to spontaneously learn how to adjust treatment planning parameters to generate high-quality treatment plans. In the 64 testing cases, with initialized parameters, quality score was 4.97 (±2.02), with 9.0 being the highest possible score. Using VTPN to perform treatment planning improved quality score to 8.44 (±0.48). CONCLUSIONS To our knowledge, this was the first time that intelligent treatment planning behaviors of human planner in external beam IMRT are autonomously encoded in an artificial intelligence system. The trained VTPN is capable of behaving in a human-like way to produce high-quality plans.
Collapse
Affiliation(s)
- Chenyang Shen
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- innovative Technology Of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Dan Nguyen
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Liyuan Chen
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Yesenia Gonzalez
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- innovative Technology Of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Rafe McBeth
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Nan Qin
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- innovative Technology Of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Steve B. Jiang
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| | - Xun Jia
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- innovative Technology Of Radiotherapy Computation and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
| |
Collapse
|
50
|
Lee J, Shin IS, Kim WC, Yoon WS, Koom WS, Rim CH. Reirradiation with intensity-modulated radiation therapy for recurrent or secondary head and neck cancer: Meta-analysis and systematic review. Head Neck 2020; 42:2473-2485. [PMID: 32437021 DOI: 10.1002/hed.26264] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 03/14/2020] [Accepted: 05/05/2020] [Indexed: 12/18/2022] Open
Abstract
BACKGROUND To summarize outcomes of reirradiation with intensity-modulated radiotherapy (IMRT) for recurrent or secondary head and neck cancer (HNC). METHODS Primary endpoints were 2-year local control (LC) and overall survival (OS). Studies involving only recurrent nasopharyngeal patients with cancer were excluded. RESULTS A total of 17 studies involving 1635 patients were included. Fourteen (82%) of those were retrospective, and 15 (88%) were from single institution. Reirradiation with IMRT produced pooled 2-year LC and OS rates of 52% (95% confidence interval [CI], 46%-57%) and 46% (95% CI, 41%-50%), respectively. In subgroup analyses, the rate of salvage surgery (<42% vs ≥42%) influenced the pooled 2-year LC rate (45.9% vs 58.5%, P = .011). The pooled rates of late grade ≥ 3 and grade 5 toxicities were 26% (95% CI, 20%-32%) and 3.1% (95% CI, 2%-5%), respectively. CONCLUSIONS Reirradiation with IMRT was an effective modality compared to historical outcomes in the pre-IMRT era.
Collapse
Affiliation(s)
- Jeongshim Lee
- Department of Radiation Oncology, Inha University Hospital, Inha University College of Medicine, Incheon, South Korea.,Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, South Korea
| | - In-Soo Shin
- Graduate School of Education, Dongguk University, Seoul, South Korea
| | - Woo Chul Kim
- Department of Radiation Oncology, Inha University Hospital, Inha University College of Medicine, Incheon, South Korea
| | - Won Sup Yoon
- Department of Radiation Oncology, Ansan Hospital, Korea University Medical College, Ansan, South Korea
| | - Woong Sub Koom
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, South Korea
| | - Chai Hong Rim
- Department of Radiation Oncology, Ansan Hospital, Korea University Medical College, Ansan, South Korea
| |
Collapse
|