1
|
Yamamoto Y, Ohira S, Kanayama N, Inui S, Ueda Y, Koike Y, Miyazaki M, Nishio T, Koizumi M, Konishi K. Comparison of dosimetric parameters and robustness for rotational errors in fractionated stereotactic irradiation using automated noncoplanar volumetric modulated arc therapy for patients with brain metastases: single- versus multi-isocentric technique. Radiol Phys Technol 2023; 16:310-318. [PMID: 37093409 DOI: 10.1007/s12194-023-00720-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 04/10/2023] [Accepted: 04/11/2023] [Indexed: 04/25/2023]
Abstract
To compare the dosimetric parameters of automated noncoplanar volumetric modulated arc therapy plans using single-isocentric (SIC) and multi-isocentric (MIC) techniques for patients with two brain metastases (BMs) in stereotactic irradiation and to evaluate the robustness of rotational errors. The SIC and MIC plans were retrospectively generated (35 Gy/five fractions) for 58 patients. Subsequently, a receiver operating characteristic curve analysis between the tumor surface distance (TSD) and V25Gy was performed to determine the thresholds for the brain tissue. The SIC and MIC plans were recalculated based on the rotational images to evaluate the dosimetric impact of rotational error. The MIC plans showed better brain tissue sparing for TSD > 6.6 cm. The SIC plans provided a significantly better conformity index for TSD ≤ 6.6 cm, while significantly lower gradient index was obtained (3.22 ± 0.56vs. 3.30 ± 0.57, p < 0.05) in the MIC plans with TSD > 6.6 cm. For organs at risk (OARs) (brainstem, chiasm, lens, optic nerves, and retinas), D0.1 cc was significantly lower (p < 0.05) in the MIC plans than in the SIC plans. The prescription dose could be delivered (D99%) to the gross tumor volume (GTV) for patients with TSD ≤ 6.6 cm when the rotational error was < 1°, whereas 31% of the D99% of GTV fell below the prescription dose with TSD > 6.6 cm. MIC plans can be an optimal approach for reducing doses to OARs and providing robustness against rotational errors in BMs with TSD > 6.6 cm.
Collapse
Affiliation(s)
- Yuki Yamamoto
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan.
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Shoki Inui
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Yuhei Koike
- Department of Radiology, Kansai Medical University, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, Osaka, 537-8567, Japan
| |
Collapse
|
2
|
Rong Y, Ding X, Daly ME. Hypofractionation and SABR: 25 years of evolution in medical physics and a glimpse of the future. Med Phys 2023. [PMID: 36756953 DOI: 10.1002/mp.16270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 12/13/2022] [Accepted: 01/30/2023] [Indexed: 02/10/2023] Open
Abstract
As we were invited to write an article for celebrating the 50th Anniversary of Medical Physics journal, on something historically significant, commemorative, and exciting happening in the past decades, the first idea came to our mind is the fascinating radiotherapy paradigm shift from conventional fractionation to hypofractionation and stereotactic ablative radiotherapy (SABR). It is historically and clinically significant since as we all know this RT treatment revolution not only reduces treatment duration for patients, but also improves tumor control and cancer treatment outcomes. It is also commemorative and exciting for us medical physicists since the technology development in medical physics has been the main driver for the success of this treatment regimen which requires high precision and accuracy throughout the entire treatment planning and delivery. This article provides an overview of the technological development and clinical trials evolvement in the past 25 years for hypofractionation and SABR, with an outlook to the future improvement.
Collapse
Affiliation(s)
- Yi Rong
- Department of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA
| | - Xuanfeng Ding
- Department of Radiation Oncology, Corewell Health, William Beaumont University Hospital, Royal Oak, Michigan, USA
| | - Megan E Daly
- Department of Radiation Oncology, University of California Davis Comprehensive Cancer Center, Sacramento, California, USA
| |
Collapse
|
3
|
Perlow HK, Dibs K, Liu K, Jiang W, Rajappa P, Blakaj DM, Palmer J, Raval RR. Whole-Brain Radiation Therapy Versus Stereotactic Radiosurgery for Cerebral Metastases. Neurosurg Clin N Am 2020; 31:565-573. [PMID: 32921352 DOI: 10.1016/j.nec.2020.06.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Whole-brain radiation therapy (WBRT) was frequently used to treat brain metastases in the past. Stereotactic radiosurgery (SRS) is now generally preferred to WBRT for patients with limited brain metastases. SRS can also be used to treat extensive brain metastases (>10-15 metastases), and clinical trials are currently comparing WBRT with SRS for extensive disease. SRS may allow for an increased risk of radiation necrosis or leptomeningeal disease dissemination after treatment. Preoperative SRS and multifraction radiotherapy decrease the risk of these side effects and may soon become standard of care. Combining SRS with immune checkpoint inhibitors may improve patient outcomes.
Collapse
Affiliation(s)
- Haley K Perlow
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA
| | - Khaled Dibs
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA
| | - Kevin Liu
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA
| | - William Jiang
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA
| | - Prajwal Rajappa
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA; Department of Neurological Surgery, Nationwide Children's Hospital, Columbus, OH, USA; Department of Pediatrics, Nationwide Children's Hospital, Columbus, OH, USA
| | - Dukagjin M Blakaj
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA
| | - Joshua Palmer
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA
| | - Raju R Raval
- Department of Radiation Oncology, The James Cancer Hospital & Solove Research Institute Ohio State University Wexner Medical Center, 460 West 10th Avenue, Suite D252, Columbus, OH 43210, USA.
| |
Collapse
|
4
|
Wada Y, Hashimoto M. Modern evidence and future prospects of external body radiation therapy for lung oligometastases of breast cancer. Transl Cancer Res 2020; 9:5077-5086. [PMID: 35117873 PMCID: PMC8799217 DOI: 10.21037/tcr.2020.02.55] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Accepted: 02/12/2020] [Indexed: 12/25/2022]
Abstract
After Hellman and Weichselbaum defined "Oligometastasis" in 1995, several local therapies for lung oligometastases including surgical resection and external body radiation therapy were reported that improved local control (LC) and progression-free survival, overall survival, and quality of life. This suggests that oligometastases is a potentially curable state. Modern advances in radiation therapy such as stereotactic body radiation therapy (SBRT) in which high dose coverage of target lesion without exposure of normal organ is possible, and are widely used to treat solitary or a limited number of primary lung cancer and metastases. Several reports showed that SBRT was a useful treatment method for lung oligometastases, and the LC rate of SBRT was 80-90% in 2 years and less invasive than surgical resection. SBRT is a safe and effective especially for small and peripheral lung metastases. However, if the metastatic lesion is big or centrally located, careful treatment is necessary to prevent radiation pneumonitis. After SBRT, it is sometimes difficult to differentiate local recurrence and pulmonary injury, especially in the early phase. However, it is important to detect local recurrence especially in patients who require further local therapy such as surgical resection and re-irradiation or systemic therapy. The diagnosis can be improved by determining the natural course after SBRT and local recurrence with computed tomography imaging and 18F-fluorodeoxyglucose positron emission tomography, respectively. Moreover, radiation therapy may have both local and systemic effects that are related to the enhancement of immune-response after radiation. Currently, several trials evaluating the benefits of SBRT for oligometastatic breast cancer are underway. However, the adaption of SBRT for lung metastases including other treatment strategies should be carefully discussed by the radiation oncologist and a multi-disciplinary team comprising a breast surgeon, medical oncologist, diagnostic radiologist, and radiation oncologist, among others.
Collapse
Affiliation(s)
- Yuki Wada
- Department of Radiology, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita, Akita 010-8543, Japan
| | - Manabu Hashimoto
- Department of Radiology, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita, Akita 010-8543, Japan
| |
Collapse
|
5
|
Kohyama S, Uematsu M, Ishihara S, Shima K, Tamai S, Kusano S. An Experience of Stereotactic Radiation Therapy for Primary Intracranial Choriocarcinoma. TUMORI JOURNAL 2018; 87:162-5. [PMID: 11504371 DOI: 10.1177/030089160108700310] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We report on a patient with choriocarcinoma in the pineal region who was successfully treated with stereotactic radiation therapy (SRT). The increased level of serum human chorionic gonadotropin (HCG) was lowered during chemotherapy with etoposide, cisplatin, and ifosfamide. However, HCG was not normalized and magnetic resonance images still showed an enhanced tumor mass with gadolinium. The patient underwent SRT of 40 Gy at an 80% isodose line per 10 fractions over'two weeks, followed by conventional craniospinal irradiation of 32.4 Gy. The level of HCG dropped below the detection limit. The patient has been in good condition for more than four years after the completion of treatment, without any signs of recurrence. We propose SRT as a valid treatment option for malignant germ cell tumors in the pineal region.
Collapse
Affiliation(s)
- S Kohyama
- Department of Radiology, National Defense Medical College, Tokorozawa, Saitama, Japan.
| | | | | | | | | | | |
Collapse
|
6
|
Ding GX, Alaei P, Curran B, Flynn R, Gossman M, Mackie TR, Miften M, Morin R, Xu XG, Zhu TC. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180. Med Phys 2018; 45:e84-e99. [PMID: 29468678 DOI: 10.1002/mp.12824] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 01/10/2018] [Accepted: 01/10/2018] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND With radiotherapy having entered the era of image guidance, or image-guided radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning and target localization. The imaging dose delivered may result in excessive dose to sensitive organs and potentially increase the chance of secondary cancers and, therefore, needs to be managed. AIMS This task group was charged with: a) providing an overview on imaging dose, including megavoltage electronic portal imaging (MV EPI), kilovoltage digital radiography (kV DR), Tomotherapy MV-CT, megavoltage cone-beam CT (MV-CBCT) and kilovoltage cone-beam CT (kV-CBCT), and b) providing general guidelines for commissioning dose calculation methods and managing imaging dose to patients. MATERIALS & METHODS We briefly review the dose to radiotherapy (RT) patients resulting from different image guidance procedures and list typical organ doses resulting from MV and kV image acquisition procedures. RESULTS We provide recommendations for managing the imaging dose, including different methods for its calculation, and techniques for reducing it. The recommended threshold beyond which imaging dose should be considered in the treatment planning process is 5% of the therapeutic target dose. DISCUSSION Although the imaging dose resulting from current kV acquisition procedures is generally below this threshold, the ALARA principle should always be applied in practice. Medical physicists should make radiation oncologists aware of the imaging doses delivered to patients under their care. CONCLUSION Balancing ALARA with the requirement for effective target localization requires that imaging dose be managed based on the consideration of weighing risks and benefits to the patient.
Collapse
Affiliation(s)
- George X Ding
- Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN, 37232, USA
| | - Parham Alaei
- University of Minnesota, Minneapolis, MN, 55455, USA
| | - Bruce Curran
- Virginia Commonwealth University, Richmond, VA, 23284, USA
| | - Ryan Flynn
- University of Iowa, Iowa City, IA, 52242, USA
| | | | | | | | | | - X George Xu
- Rensselaer Polytechnic Institute, Troy, NY, 12180, USA
| | - Timothy C Zhu
- University of Pennsylvania, Philadelphia, PA, 19104, USA
| |
Collapse
|
7
|
Shirato H, Le QT, Kobashi K, Prayongrat A, Takao S, Shimizu S, Giaccia A, Xing L, Umegaki K. Selection of external beam radiotherapy approaches for precise and accurate cancer treatment. JOURNAL OF RADIATION RESEARCH 2018; 59:i2-i10. [PMID: 29373709 PMCID: PMC5868193 DOI: 10.1093/jrr/rrx092] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Indexed: 05/05/2023]
Abstract
Physically precise external-beam radiotherapy (EBRT) technologies may not translate to the best outcome in individual patients. On the other hand, clinical considerations alone are often insufficient to guide the selection of a specific EBRT approach in patients. We examine the ways in which to compare different EBRT approaches based on physical, biological and clinical considerations, and how they can be enhanced with the addition of biophysical models and machine-learning strategies. The process of selecting an EBRT modality is expected to improve in tandem with knowledge-based treatment planning.
Collapse
Affiliation(s)
- Hiroki Shirato
- Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Corresponding author. Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan. Tel: +81-11-706-5977; Fax: +81-11-706-7876;
| | - Quynh-Thu Le
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA, USA
| | - Keiji Kobashi
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Anussara Prayongrat
- Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
| | - Seishin Takao
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| | - Shinichi Shimizu
- Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
| | - Amato Giaccia
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA, USA
| | - Lei Xing
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA, USA
| | - Kikuo Umegaki
- Global Station for Quantum Medical Science and Engineering, Global Institute for Cooperative Research and Education, Hokkaido University, North-15 West-7, Kita-ku, 0608638, Sapporo, Hokkaido, Japan
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
| |
Collapse
|
8
|
Hua C, Yao W, Kidani T, Tomida K, Ozawa S, Nishimura T, Fujisawa T, Shinagawa R, Merchant TE. A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance. Br J Radiol 2017; 90:20170266. [PMID: 28830239 DOI: 10.1259/bjr.20170266] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVE A ceiling-mounted robotic C-arm cone beam CT (CBCT) system was developed for use with a 190° proton gantry system and a 6-degree-of-freedom robotic patient positioner. We report on the mechanical design, system accuracy, image quality, image guidance accuracy, imaging dose, workflow, safety and collision-avoidance. METHODS The robotic CBCT system couples a rotating C-ring to the C-arm concentrically with a kV X-ray tube and a flat-panel imager mounted to the C-ring. CBCT images are acquired with flex correction and maximally 360° rotation for a 53 cm field of view. The system was designed for clinical use with three imaging locations. Anthropomorphic phantoms were imaged to evaluate the image guidance accuracy. RESULTS The position accuracy and repeatability of the robotic C-arm was high (<0.5 mm), as measured with a high-accuracy laser tracker. The isocentric accuracy of the C-ring rotation was within 0.7 mm. The coincidence of CBCT imaging and radiation isocentre was better than 1 mm. The average image guidance accuracy was within 1 mm and 1° for the anthropomorphic phantoms tested. Daily volumetric imaging for proton patient positioning was specified for routine clinical practice. CONCLUSION Our novel gantry-independent robotic CBCT system provides high-accuracy volumetric image guidance for proton therapy. Advances in knowledge: Ceiling-mounted robotic CBCT provides a viable option than CT on-rails for partial gantry and fixed-beam proton systems with the added advantage of acquiring images at the treatment isocentre.
Collapse
Affiliation(s)
- Chiaho Hua
- 1 Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Weiguang Yao
- 1 Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Takao Kidani
- 2 Proton Therapy Systems Design Department, Hitachi Ltd, Hitachi-shi, Japan
| | - Kazuo Tomida
- 2 Proton Therapy Systems Design Department, Hitachi Ltd, Hitachi-shi, Japan
| | - Saori Ozawa
- 2 Proton Therapy Systems Design Department, Hitachi Ltd, Hitachi-shi, Japan
| | - Takenori Nishimura
- 2 Proton Therapy Systems Design Department, Hitachi Ltd, Hitachi-shi, Japan
| | - Tatsuya Fujisawa
- 2 Proton Therapy Systems Design Department, Hitachi Ltd, Hitachi-shi, Japan
| | - Ryousuke Shinagawa
- 2 Proton Therapy Systems Design Department, Hitachi Ltd, Hitachi-shi, Japan
| | - Thomas E Merchant
- 1 Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, USA
| |
Collapse
|
9
|
Papalazarou C, Klop GJ, Milder MT, Marijnissen JP, Gupta V, Heijmen BJ, Nuyttens JJ, Hoogeman MS. CyberKnife with integrated CT-on-rails: System description and first clinical application for pancreas SBRT. Med Phys 2017; 44:4816-4827. [DOI: 10.1002/mp.12432] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Revised: 06/05/2017] [Accepted: 06/15/2017] [Indexed: 12/16/2022] Open
Affiliation(s)
- Chrysi Papalazarou
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Gijsbert J. Klop
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Maaike T.W. Milder
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Johannes P.A. Marijnissen
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Vikas Gupta
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Ben J.M. Heijmen
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Joost J.M.E. Nuyttens
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| | - Mischa S. Hoogeman
- Department of Radiation Oncology; Erasmus MC Cancer Institute; Groene Hilledijk 301 Rotterdam 3075 EA The Netherlands
| |
Collapse
|
10
|
Dan T, Williams NL. Management of Stage I Lung Cancer with Stereotactic Ablative Radiation Therapy. Surg Oncol Clin N Am 2017; 26:393-403. [PMID: 28576179 DOI: 10.1016/j.soc.2017.01.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Early stage non-small cell lung cancer is a growing clinical entity with evolving standards of care. With the adoption of lung screening guidelines, the incidence of early stage disease is expected to increase. Surgical resection for early stage disease has been considered standard of care; however, there is evidence that stereotactic ablative radiation therapy (SABR) may be a viable alternate to surgery. In the last decade, advances in image guidance, treatment planning systems, and improved spatial accuracy of treatment delivery have converged to result in the effective use of SABR in the treatment of early stage lung cancer.
Collapse
Affiliation(s)
- Tu Dan
- Department of Radiation Oncology, UT Southwestern, 5323 Harry Hines Boulevard, Dallas, TX 75390, USA.
| | - Noelle L Williams
- Department of Radiation Oncology, Thomas Jefferson University, 111 South 11th Street, Philadelphia, PA 19107, USA
| |
Collapse
|
11
|
Camps S, van der Meer S, Verhaegen F, Fontanarosa D. Various approaches for pseudo-CT scan creation based on ultrasound to ultrasound deformable image registration between different treatment time points for radiotherapy treatment plan adaptation in prostate cancer patients. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/3/035018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
12
|
Kim J, Li S, Pradhan D, Hammoud R, Chen Q, Yin FF, Zhao Y, Kim JH, Movsas B. Comparison of Similarity Measures for Rigid-body CT/Dual X-ray Image Registrations. Technol Cancer Res Treat 2016; 6:337-46. [PMID: 17668942 DOI: 10.1177/153303460700600411] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
A set of experiments were conducted to evaluate six similarity measures for intensity-based rigid-body 3D/2D image registration. Similarity measure is an index that measures the similarity between a digitally reconstructed radiograph (DRR) and an x-ray planar image. The registration is accomplished by maximizing the sum of the similarity measures between biplane x-ray images and the corresponding DRRs in an iterative fashion. We have evaluated the accuracy and attraction ranges of the registrations using six different similarity measures on phantom experiments for head, thorax, and pelvis. The images were acquired using Varian Medial System On-Board Imager. Our results indicated that normalized cross correlation and entropy of difference showed a wide attraction range (62 deg and 83 mm mean attraction range, ωmean), but the worst accuracy (4.2 mm maximum error, emax). The gradient-based similarity measures, gradient correlation and gradient difference, and the pattern intensity showed sub-millimeter accuracy, but narrow attraction ranges ( ωmean=29 deg, 31 mm). Mutual information was in-between of these two groups ( emax=2.5 mm, ωmean= 48 deg, 52 mm). On the data of 120 x-ray pairs from eight IRB approved prostate patients, the gradient difference showed the best accuracy. In the clinical applications, registrations starting with the mutual information followed by the gradient difference may provide the best accuracy and the most robustness.
Collapse
Affiliation(s)
- Jinkoo Kim
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI 48202, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
13
|
van Vulpen M, Wang L, Orton CG. Within the next five years, adaptive hypofractionation will become the most common form of radiotherapy. Med Phys 2016; 43:3941. [DOI: 10.1118/1.4951735] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
|
14
|
Fontanarosa D, van der Meer S, Bamber J, Harris E, O'Shea T, Verhaegen F. Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management. Phys Med Biol 2015; 60:R77-114. [PMID: 25592664 DOI: 10.1088/0031-9155/60/3/r77] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
In modern radiotherapy, verification of the treatment to ensure the target receives the prescribed dose and normal tissues are optimally spared has become essential. Several forms of image guidance are available for this purpose. The most commonly used forms of image guidance are based on kilovolt or megavolt x-ray imaging. Image guidance can also be performed with non-harmful ultrasound (US) waves. This increasingly used technique has the potential to offer both anatomical and functional information.This review presents an overview of the historical and current use of two-dimensional and three-dimensional US imaging for treatment verification in radiotherapy. The US technology and the implementation in the radiotherapy workflow are described. The use of US guidance in the treatment planning process is discussed. The role of US technology in inter-fraction motion monitoring and management is explained, and clinical studies of applications in areas such as the pelvis, abdomen and breast are reviewed. A companion review paper (O'Shea et al 2015 Phys. Med. Biol. submitted) will extensively discuss the use of US imaging for intra-fraction motion quantification and novel applications of US technology to RT.
Collapse
Affiliation(s)
- Davide Fontanarosa
- Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center (MUMC), Maastricht 6201 BN, the Netherlands. Oncology Solutions Department, Philips Research, High Tech Campus 34, Eindhoven 5656 AE, the Netherlands
| | | | | | | | | | | |
Collapse
|
15
|
Nishio T, Shirato H, Ishikawa M, Miyabe Y, Kito S, Narita Y, Onimaru R, Ishikura S, Ito Y, Hiraoka M. Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702). JOURNAL OF RADIATION RESEARCH 2014; 55:600-7. [PMID: 24385469 PMCID: PMC4014158 DOI: 10.1093/jrr/rrt135] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 08/31/2013] [Accepted: 10/24/2013] [Indexed: 05/27/2023]
Abstract
A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institutions, and differences in the irradiating dose between the institutions were investigated. We developed a water tank-type lung phantom appropriate for verification of the exposure dose in lung SBRT. Using this water tank-type lung phantom, the dose calculated in the radiation treatment-planning system and the measured dose using a free air ionization chamber and dosimetric film were compared in a visiting survey of the seven institutions participating in the clinical study. In all participating institutions, differences between the calculated and the measured dose in the irradiation plan were as follows: the accuracy of the absolute dose in the center of the simulated tumor measured using a free air ionization chamber was within 2%, the mean gamma value was ≤ 0.47 on gamma analysis following the local dose criteria, and the pass rate was >87% for 3%/3 mm from measurement of dose distribution with dosimetric film. These findings confirmed the accuracy of delivery doses in the institutions participating in the clinical study, so that a study with integration of the institutions could be initiated.
Collapse
Affiliation(s)
- Teiji Nishio
- Particle Therapy Division, Research Center for Innovative Oncology, National Cancer Center, 6-5-1, Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| | - Hiroki Shirato
- Department of Radiation Medicine, Graduate School of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Masayori Ishikawa
- Department of Medical Physics and Engineering, Graduate School of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Yuki Miyabe
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Yoshida-Konoe-cho, Sakyo-ku, Kyoto, 606-8501, Japan
| | - Satoshi Kito
- Department of Radiotherapy, Tokyo Metropolitan Cancer and Infectious Diseases Center, Komagome Hospital, 18-22, Honkomagome 3chome, Bunkyo-ku, Tokyo, 113-8677, Japan
| | - Yuichirou Narita
- Department of Radiology and Radiation Oncology, Graduate School of Medicine, Hirosaki University, 5, Zaifu-cho, Hirosaki, Aomori, 036-8563, Japan
| | - Rikiya Onimaru
- Department of Radiation Medicine, Graduate School of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido, 060-8638, Japan
| | - Satoshi Ishikura
- Department of Radiation Oncology, Juntendo University, 3-1-3, Hongo, Bunkyo-ku, 113-8431, Tokyo, Japan
| | - Yoshinori Ito
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo, 104-1145, Japan
| | - Masahiro Hiraoka
- Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Yoshida-Konoe-cho, Sakyo-ku, Kyoto, 606-8501, Japan
| |
Collapse
|
16
|
Jaffray D, Kupelian P, Djemil T, Macklis RM. Review of image-guided radiation therapy. Expert Rev Anticancer Ther 2014; 7:89-103. [PMID: 17187523 DOI: 10.1586/14737140.7.1.89] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Image-guided radiation therapy represents a new paradigm in the field of high-precision radiation medicine. A synthesis of recent technological advances in medical imaging and conformal radiation therapy, image-guided radiation therapy represents a further expansion in the recent push for maximizing targeting capabilities with high-intensity radiation dose deposition limited to the true target structures, while minimizing radiation dose deposited in collateral normal tissues. By improving this targeting discrimination, the therapeutic ratio may be enhanced significantly. The principle behind image-guided radiation therapy relies heavily on the acquisition of serial image datasets using a variety of medical imaging platforms, including computed tomography, ultrasound and magnetic resonance imaging. These anatomic and volumetric image datasets are now being augmented through the addition of functional imaging. The current interest in positron-emitted tomography represents a good example of this sort of functional information now being correlated with anatomic localization. As the sophistication of imaging datasets grows, the precise 3D and 4D positions of the target and normal structures become of great relevance, leading to a recent exploration of real- or near-real-time positional replanning of the radiation treatment localization coordinates. This 'adaptive' radiotherapy explicitly recognizes that both tumors and normal tissues change position in time and space during a multiweek course of treatment, and even within a single treatment fraction. As targets and normal tissues change, the attenuation of radiation beams passing through these structures will also change, thus adding an additional level of imprecision in targeting unless these changes are taken into account. All in all, image-guided radiation therapy can be seen as further progress in the development of minimally invasive highly targeted cytotoxic therapies with the goal of substituting remote technologies for direct contact on the part of an operator or surgeon. Although data demonstrating clear-cut superiority of this new high-tech paradigm compared with more conventional radiation treatment approaches are scant, the emergence of preliminary data from several early studies shows that interest in this field is broad based and robust. As outcomes data accumulate, it is very likely that this field will continue to expand greatly. Although at present most of the work is being performed at major academic centers, the enthusiastic adoption of many of the devices and approaches being developed for this field suggest a rapid penetration into the community and the use of the technology by teams of specialists in the fields of radiation medicine, radiation physics and various branches of surgery. A recent survey of practitioners predicted very widespread adoption within the next 10 years.
Collapse
Affiliation(s)
- David Jaffray
- Princess Margaret Hospital /University of Toronto, Radiation Medicine Program, Toronto, Ontario, Canada.
| | | | | | | |
Collapse
|
17
|
De Los Santos J, Popple R, Agazaryan N, Bayouth JE, Bissonnette JP, Bucci MK, Dieterich S, Dong L, Forster KM, Indelicato D, Langen K, Lehmann J, Mayr N, Parsai I, Salter W, Tomblyn M, Yuh WTC, Chetty IJ. Image guided radiation therapy (IGRT) technologies for radiation therapy localization and delivery. Int J Radiat Oncol Biol Phys 2013; 87:33-45. [PMID: 23664076 DOI: 10.1016/j.ijrobp.2013.02.021] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2012] [Revised: 02/14/2013] [Accepted: 02/16/2013] [Indexed: 12/27/2022]
Affiliation(s)
- Jennifer De Los Santos
- Department of Radiation Oncology, University of Alabama at Birmingham, Birmingham, Alabama, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Reproducibility of diaphragm position assessed with a voluntary breath-holding device. Jpn J Radiol 2013; 31:357-63. [PMID: 23526485 DOI: 10.1007/s11604-013-0199-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2012] [Accepted: 03/03/2013] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate the reproducibility of diaphragm position in our new breath-holding radiotherapy for abdominal tumors using image-guided radiation therapy (IGRT) and a voluntary breath-holding device, Abches. MATERIALS AND METHODS Patients treated with abdominal tumors using IGRT with Abches were enrolled. Twenty patients without dementia or severe lung disease were analyzed. Each fraction of all patients was set up with kV cone-beam CT with reference to the vertebral bodies. Before daily treatment, electronic portal imaging device (EPID) images of the diaphragm at breath-holding exhale phase were acquired. The difference in the diaphragm position relative to the vertebral body was analyzed by comparing EPID images and the digitally reconstructed radiograph of the planning CT. We evaluated the reproducibility of two axes: superior-inferior (S-I) and right-left (R-L) with the EPID measurements. RESULTS The 443 irradiation data sets were analyzed. The interfractional reproducibility of the diaphragm relative to vertebral bodies was 1.7 ± 1.4 mm in the S-I and 1.4 ± 1.2 mm in the R-L direction. CONCLUSION This technique has good interfractional reproducibility and visibility of the diaphragm during irradiation. Its use is feasible in the routine clinical setting and irradiation.
Collapse
|
19
|
Onishi H, Araki T. Stereotactic body radiation therapy for stage I non-small-cell lung cancer: a historical overview of clinical studies. Jpn J Clin Oncol 2013; 43:345-50. [PMID: 23436937 DOI: 10.1093/jjco/hyt014] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Because of difficulties with stabilization, breathing motion and dosimetry, stereotactic body radiotherapy for lung cancer has only been practiced for the past 15 years. However, a large amount of case data has rapidly been accumulated in recent years. Stereotactic body radiotherapy for Stage I non-small-cell lung cancer has been actively investigated in inoperable patients since around 1995, and a number of clinical trials have been undertaken. Early studies from 2001 presented a 3-year local control rate of 94% and a 3-year overall survival rate of 66% for patients receiving 50-60 Gy in 10 fractions. Another study in 2005, using 48 Gy in four fractions, presented a 3-year local control rate of 98% and 3-year overall survival rates of 83% for Stage IA patients and 72% for Stage IB patients. A multi-institutional study showed favorable local control and survival rates in a group receiving a biologically effective dose of 100 Gy. A dose-escalation study in the USA suggested a maximum tolerated dose of 60 Gy in three fractions. A Phase II clinical trial (RTOG0236) followed, with a reported 3-year local control rate of 98% and a 3-year overall survival rate of 56% for patients who received 60 Gy in three fractions. A Japanese Phase II clinical trial (JCOG0403) investigated a dose of 48 Gy in four fractions among 165 Stage IA patients, showing a 3-year survival rate of 76% and a 3-year locally progression-free survival rate of 69% for the operable group. An overview of past clinical trials in stereotactic body radiotherapy for Stage I non-small-cell lung cancer and current issues is presented and discussed.
Collapse
Affiliation(s)
- Hiroshi Onishi
- Department of Radiology, Yamanashi University, Yamanashi, Japan.
| | | |
Collapse
|
20
|
Dhabaan A, Schreibmann E, Siddiqi A, Elder E, Fox T, Ogunleye T, Esiashvili N, Curran W, Crocker I, Shu HK. Six degrees of freedom CBCT-based positioning for intracranial targets treated with frameless stereotactic radiosurgery. J Appl Clin Med Phys 2012; 13:3916. [PMID: 23149782 PMCID: PMC5718543 DOI: 10.1120/jacmp.v13i6.3916] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2012] [Revised: 06/22/2012] [Accepted: 06/29/2012] [Indexed: 11/23/2022] Open
Abstract
Frameless radiosurgery is an attractive alternative to the framed procedure if it can be performed with comparable precision in a reasonable time frame. Here, we present a positioning approach for frameless radiosurgery based on in-room volumetric imaging coupled with an advanced six-degrees-of-freedom (6 DOF) image registration technique which avoids use of a bite block. Patient motion is restricted with a custom thermoplastic mask. Accurate positioning is achieved by registering a cone-beam CT to the planning CT scan and applying all translational and rotational shifts using a custom couch mount. System accuracy was initially verified on an anthropomorphic phantom. Isocenters of delineated targets in the phantom were computed and aligned by our system with an average accuracy of 0.2 mm, 0.3 mm, and 0.4 mm in the lateral, vertical, and longitudinal directions, respectively. The accuracy in the rotational directions was 0.1°, 0.2°, and 0.1° in the pitch, roll, and yaw, respectively. An additional test was performed using the phantom in which known shifts were introduced. Misalignments up to 10 mm and 3° in all directions/rotations were introduced in our phantom and recovered to an ideal alignment within 0.2 mm, 0.3 mm, and 0.4 mm in the lateral, vertical, and longitudinal directions, respectively, and within 0.3° in any rotational axis. These values are less than couch motion precision. Our first 28 patients with 38 targets treated over 63 fractions are analyzed in the patient positioning phase of the study. Mean error in the shifts predicted by the system were less than 0.5 mm in any translational direction and less than 0.3° in any rotation, as assessed by a confirmation CBCT scan. We conclude that accurate and efficient frameless radiosurgery positioning is achievable without the need for a bite block by using our 6DOF registration method. This system is inexpensive compared to a couch-based 6 DOF system, improves patient comfort compared to systems that utilize a bite block, and is ideal for the treatment of pediatric patients with or without general anesthesia, as well as of patients with dental issues. From this study, it is clear that only adjusting for 4 DOF may, in some cases, lead to significant compromise in PTV coverage. Since performing the additional match with 6 DOF in our registration system only adds a relatively short amount of time to the overall process, we advocate making the precise match in all cases.
Collapse
Affiliation(s)
- Anees Dhabaan
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Stereotactic body radiotherapy for metachronous multisite oligo-recurrence: a long-surviving case with sequential oligo-recurrence in four different organs treated using locally radical radiotherapy and a review of the literature. Pulm Med 2012; 2012:713073. [PMID: 23150822 PMCID: PMC3486341 DOI: 10.1155/2012/713073] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2012] [Accepted: 09/13/2012] [Indexed: 12/12/2022] Open
Abstract
Stereotactic body radiotherapy (SBRT) for oligometastases represents a recent trend in radiation oncology. While abundant data are available regarding the use of SBRT for the treatment of lung or liver oligometastases from various retrospective series and prospective trials, relatively little information has been accumulated for the treatment of oligometastases at sites other than the lungs and liver, particularly for sequential oligometastases in multiple organs. Oligometastases with primary lesions controlled is called “oligo-recurrence.” We describe herein the case of a lung cancer patient who developed repeated oligo-recurrence at multiple sites that were each controlled by radical radiotherapy and achieved long-term survival and discuss the merits of locally aggressive radiotherapy for this type of disease condition with reviewing the literature. Although further investigation should be undertaken to clarify the benefits, objectives, and methods of SBRT for the treatment of oligometastases, we believe utilization of SBRT may be worthwhile for patients with remote metastases who hope for treatment to acquire better local control and possible longer survival.
Collapse
|
22
|
Bissonnette JP, Balter PA, Dong L, Langen KM, Lovelock DM, Miften M, Moseley DJ, Pouliot J, Sonke JJ, Yoo S. Quality assurance for image-guided radiation therapy utilizing CT-based technologies: A report of the AAPM TG-179. Med Phys 2012; 39:1946-63. [PMID: 22482616 DOI: 10.1118/1.3690466] [Citation(s) in RCA: 199] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
23
|
Alexander EJ, Harris VA, Sohaib A, Dearnaley D. Reducing the side effects of external beam radiotherapy in prostate cancer: role of imaging techniques. ACTA ACUST UNITED AC 2012. [DOI: 10.2217/iim.11.65] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
24
|
Yi BSK, Perks J, Houston R, Stern R, Purdy JA, Chen AM. Changes in position and volume of lung cancer target volumes during stereotactic body radiotherapy (SBRT): is image guidance necessary? Technol Cancer Res Treat 2012; 10:495-504. [PMID: 21895034 DOI: 10.7785/tcrt.2012.500226] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
The purpose of this study was to analyze inter- and intra-fractional changes in tumor volume with respect to both spatial and volumetric parameters among patients treated by SBRT for lung cancer. Twelve patients (13 tumors) were treated by SBRT with abdominal compression in 3-5 fractions over a 2 week period to a median dose of 60 Gy (range, 48 to 60 Gy). Kilovoltage cone-beam CT (CBCT) was obtained prior to the delivery of each fraction as well as intra-fractionally yielding a total of 55 CBCT scans. All CBCT scans were registered with the planning CT for target alignment and shifts were recorded and analyzed. Retrospectively, gross tumor volume (GTV) was contoured on all CBCT images and compared to initial planning volumes; positional differences were evaluated utilizing directional and vector analysis. Shifts greater than 5 mm were applied inter-fractionally in 6.8% (lateral), 29.5% (longitudinal), and 6.8% (vertical) of all delivered treatments. Using a 10 mm threshold, the corresponding percentages were 2.3%, 13.6%, and 2.3%, respectively. Across all fractions, the calculated inter-fractional shift vectors ranged from 0 to 31.2 mm, with 40.9%, 15.9%, and 11.4% of all fractions having shift vectors≥5 mm, ≥10 mm, and ≥20 mm, respectively. Intra-fractional shifts were also evaluated and found negligible in a small portion of patients evaluated. The mean overall reduction in GTV was 21.1% during SBRT. Significant changes in both position and volume occur during SBRT for lung cancer. Shifts (particularly in the superior-inferior axis) may exceed applied margins and compromise target coverage. Due to the extreme hypofractionation associated with SBRT, inter-fractional image guidance is necessary.
Collapse
Affiliation(s)
- B S K Yi
- Department of Radiation Oncology, University of California, Davis Cancer Center 4501 "X" St, G-140 Sacramento, CA 95817, USA
| | | | | | | | | | | |
Collapse
|
25
|
Historical Development of Stereotactic Ablative Radiotherapy. STEREOTACTIC BODY RADIATION THERAPY 2012. [DOI: 10.1007/174_2012_540] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
26
|
Price GJ, Parkhurst JM, Sharrock PJ, Moore CJ. Real-time optical measurement of the dynamic body surface for use in guided radiotherapy. Phys Med Biol 2011; 57:415-36. [PMID: 22173038 DOI: 10.1088/0031-9155/57/2/415] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Optical measurements are increasingly used in radiotherapy. In this paper we present, in detail, the design and implementation of a multi-channel optical system optimized for fast, high spatial resolution, dynamic body surface measurement in guided therapy. We include all algorithmic modifications and calibration procedures required to create a robust, practical system for clinical use. Comprehensive static and dynamic phantom validation measurements in the radiotherapy treatment room show: conformance with simultaneously measured cone beam CT data to within 1 mm over 62% ± 8% of the surface and 2 mm over 90% ± 3%; agreement with the measured radius of a precision geometrical phantom to within 1 mm; and true real-time performance with image capture through to surface display at 23 Hz. An example patient dataset is additionally included, indicating similar performance in the clinic.
Collapse
Affiliation(s)
- G J Price
- Developing Technologies, Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK.
| | | | | | | |
Collapse
|
27
|
Kron T, Eyles D, Schreiner LJ, Battista J. Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal. J Med Phys 2011; 31:242-54. [PMID: 21206640 PMCID: PMC3004099 DOI: 10.4103/0971-6203.29194] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2006] [Accepted: 08/01/2006] [Indexed: 11/04/2022] Open
Abstract
Magnetic resonance imaging (MRI) provides excellent soft tissue contrast for oncology applications. We propose to combine a MRI scanner with a helical tomotherapy (HT) system to enable daily target imaging for improved conformal radiation dose delivery to a patient. HT uses an intensity-modulated fan-beam that revolves around a patient, while the patient slowly advances through the plane of rotation, yielding a helical beam trajectory. Since the use of a linear accelerator to produce radiation may be incompatible with the pulsed radiofrequency and the high and pulsed magnetic fields required for MRI, it is proposed that a radioactive Cobalt-60 ((60)Co) source be used instead to provide the radiation. An open low field (0.25 T) MRI system is proposed where the tomotherapy ring gantry is located between two sets of Helmholtz coils that can generate a sufficiently homogenous main magnetic field.It is shown that the two major challenges with the design, namely acceptable radiation dose rate (and therefore treatment duration) and moving parts in strong magnetic field, can be addressed. The high dose rate desired for helical tomotherapy delivery can be achieved using two radiation sources of 220TBq (6000Ci) each on a ring gantry with a source to axis-of-rotation distance of 75 cm. In addition to this, a dual row multi-leaf collimator (MLC) system with 15 mm leaf width at isocentre and relatively large fan beam widths between 15 and 30 mm per row shall be employed. In this configuration, the unit would be well-suited for most pelvic radiotherapy applications where the soft tissue contrast of MRI will be particularly beneficial. Non-magnetic MRI compatible materials must be used for the rotating gantry. Tungsten, which is non-magnetic, can be used for primary collimation of the fan-beam as well as for the MLC, which allows intensity modulated radiation delivery. We propose to employ a low magnetic Cobalt compound, sycoporite (CoS) for the Cobalt source material itself.Rotational delivery is less susceptible to problems related to the use of a low energy megavoltage photon source while the helical delivery reduces the negative impact of the relatively large penumbra inherent in the use of Cobalt sources for radiotherapy. On the other hand, the use of a (60)Co source ensures constant dose rate with gantry rotation and makes dose calculation in a magnetic field as easy as the range of secondary electrons is limited.The MR-integrated Cobalt tomotherapy unit, dubbed 'MiCoTo,' uses two independent physical principles for image acquisition and treatment delivery. It would offer excellent target definition and will allow following target motion during treatment using fast imaging techniques thus providing the best possible input for adaptive radiotherapy. As an additional bonus, quality assurance of the radiation delivery can be performed in situ using radiation sensitive gels imaged by MRI.
Collapse
Affiliation(s)
- Tomas Kron
- Peter MacCallum Cancer Centre, Melbourne, Australia
| | | | | | | |
Collapse
|
28
|
Ding GX, Munro P, Pawlowski J, Malcolm A, Coffey CW. Reducing radiation exposure to patients from kV-CBCT imaging. Radiother Oncol 2010; 97:585-92. [DOI: 10.1016/j.radonc.2010.08.005] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2009] [Revised: 07/29/2010] [Accepted: 08/03/2010] [Indexed: 10/19/2022]
|
29
|
Abstract
This paper reviews the integration of imaging and radiation oncology, and discusses challenges and opportunities for improving the practice of radiation oncology with imaging. An inherent goal of radiation therapy is to deliver enough dose to the tumor to eradicate all cancer cells or to palliate symptoms, while avoiding normal tissue injury. Imaging for cancer diagnosis, staging, treatment planning, and radiation targeting has been integrated in various ways to improve the chance of this occurring. A large spectrum of imaging strategies and technologies has evolved in parallel to advances in radiation delivery. The types of imaging can be categorized into offline imaging (outside the treatment room) and online imaging (inside the treatment room, conventionally termed image-guided radiation therapy). The direct integration of images in the radiotherapy planning process (physically or computationally) often entails trade-offs in imaging performance. Although such compromises may be acceptable given specific clinical objectives, general requirements for imaging performance are expected to increase as paradigms for radiation delivery evolve to address underlying biology and adapt to radiation responses. This paper reviews the integration of imaging and radiation oncology, and discusses challenges and opportunities for improving the practice of radiation oncology with imaging.
Collapse
Affiliation(s)
- Laura A Dawson
- Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, Toronto, Ontario, Canada.
| | | |
Collapse
|
30
|
Ding GX, Coffey CW. Beam characteristics and radiation output of a kilovoltage cone-beam CT. Phys Med Biol 2010; 55:5231-48. [DOI: 10.1088/0031-9155/55/17/022] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
31
|
Onishi H, Shirato H, Nagata Y, Hiraoka M, Fujino M, Gomi K, Karasawa K, Hayakawa K, Niibe Y, Takai Y, Kimura T, Takeda A, Ouchi A, Hareyama M, Kokubo M, Kozuka T, Arimoto T, Hara R, Itami J, Araki T. Stereotactic body radiotherapy (SBRT) for operable stage I non-small-cell lung cancer: can SBRT be comparable to surgery? Int J Radiat Oncol Biol Phys 2010; 81:1352-8. [PMID: 20638194 DOI: 10.1016/j.ijrobp.2009.07.1751] [Citation(s) in RCA: 436] [Impact Index Per Article: 31.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2009] [Revised: 07/21/2009] [Accepted: 07/22/2009] [Indexed: 12/11/2022]
Abstract
PURPOSE To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non-small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. PATIENTS AND METHODS Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n=65; T2N0M0, n=22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45-72.5 Gy at the isocenter, administered in 3-10 fractions. Median calculated biological effective dose was 116 Gy (range, 100-141 Gy). Data were collected and analyzed retrospectively. RESULTS During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. CONCLUSION Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery.
Collapse
Affiliation(s)
- Hiroshi Onishi
- Department of Radiology, School of Medicine, Yamanashi University, Yamanashi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Bose S, Shukla H, Maltz J. Beam-centric algorithm for pretreatment patient position correction in external beam radiation therapy. Med Phys 2010; 37:2004-16. [PMID: 20527534 DOI: 10.1118/1.3327457] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In current image guided pretreatment patient position adjustment methods, image registration is used to determine alignment parameters. Since most positioning hardware lacks the full six degrees of freedom (DOF), accuracy is compromised. The authors show that such compromises are often unnecessary when one models the planned treatment beams as part of the adjustment calculation process. The authors present a flexible algorithm for determining optimal realizable adjustments for both step-and-shoot and arc delivery methods. METHODS The beam shape model is based on the polygonal intersection of each beam segment with the plane in pretreatment image volume that passes through machine isocenter perpendicular to the central axis of the beam. Under a virtual six-DOF correction, ideal positions of these polygon vertices are computed. The proposed method determines the couch, gantry, and collimator adjustments that minimize the total mismatch of all vertices over all segments with respect to their ideal positions. Using this geometric error metric as a function of the number of available DOF, the user may select the most desirable correction regime. RESULTS For a simulated treatment plan consisting of three equally weighted coplanar fixed beams, the authors achieve a 7% residual geometric error (with respect to the ideal correction, considered 0% error) by applying gantry rotation as well as translation and isocentric rotation of the couch. For a clinical head-and-neck intensity modulated radiotherapy plan with seven beams and five segments per beam, the corresponding error is 6%. Correction involving only couch translation (typical clinical practice) leads to a much larger 18% mismatch. Clinically significant consequences of more accurate adjustment are apparent in the dose volume histograms of target and critical structures. CONCLUSIONS The algorithm achieves improvements in delivery accuracy using standard delivery hardware without significantly increasing total treatment session duration. It encourages parsimonious utilization of all available DOF. Finally, in certain cases, it obviates the need of a robotic couch having six DOF for the correction of patient displacement and rotations.
Collapse
Affiliation(s)
- Supratik Bose
- Oncology Care Systems Group, Siemens Medical Solutions, 4040 Nelson Avenue, Concord, California 94520, USA.
| | | | | |
Collapse
|
33
|
Chow JCL. Cone-beam CT dosimetry for the positional variation in isocenter: A Monte Carlo study. Med Phys 2009; 36:3512-20. [DOI: 10.1118/1.3166934] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
34
|
ZIELIŃSKA-DĄBROWSKA S, KUKOŁOWICZ PF, CZEBEK-SZEBEK P. Comparison of image registration performed with MV cone beam CT and CT on rails and Syngo™ Adaptive Targeting software. Rep Pract Oncol Radiother 2009. [DOI: 10.1016/s1507-1367(10)60027-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
35
|
Walters BRB, Ding GX, Kramer R, Kawrakow I. Skeletal dosimetry in cone beam computed tomography. Med Phys 2009; 36:2915-22. [DOI: 10.1118/1.3147143] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
36
|
Ding GX, Coffey CW. Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. Int J Radiat Oncol Biol Phys 2009; 73:610-7. [PMID: 19147025 DOI: 10.1016/j.ijrobp.2008.10.006] [Citation(s) in RCA: 124] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2008] [Revised: 09/02/2008] [Accepted: 10/02/2008] [Indexed: 10/21/2022]
Abstract
PURPOSE Image-guided radiation therapy has emerged as the new paradigm in radiotherapy. This work is to provide detailed information concerning the additional imaging doses to patients' radiosensitive organs from a kilovoltage cone beam computed tomography (kV CBCT) scan procedure. METHODS AND MATERIALS The Vanderbilt-Monte-Carlo-Beam-Calibration (VMCBC; Vanderbilt University, Nashville, TN) algorithm was used to calculate radiation dose to organs resulting from a kV CBCT imaging guidance procedure. Eight patients, including 3 pediatric and 5 adult patients, were investigated. The CBCT scans in both full- and half-fan modes were studied. RESULTS For a head-and-neck scan in half-fan mode, dose-volume histogram analyses show mean doses of 7 and 8 cGy to the eyes, 5 and 6 cGy to the spinal cord, 5 and 6 cGy to the brain, and 18 and 23 cGy to the cervical vertebrae for an adult and a 29-month-old child, respectively. The dose from a scan in full-fan mode is 10-20% lower than that in half-fan mode. For an abdominal scan, mean doses are 3 and 7 cGy to prostate and 7 and 17 cGy to femoral heads for a large adult patient and a 31-month-old pediatric patient, respectively. CONCLUSIONS Doses to radiosensitive organs can total 300 cGy accrued over an entire treatment course if kV CBCT scans are acquired daily. These findings provide needed data for clinicians to make informed decisions concerning additional imaging doses. The dose to bone is two to four times greater than dose to soft tissue for kV x-rays, which should be considered, especially for pediatric patients.
Collapse
Affiliation(s)
- George X Ding
- Vanderbilt-Ingram Cancer Center, Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN, USA
| | | |
Collapse
|
37
|
Chen GTY, Sharp GC, Mori S. A review of image-guided radiotherapy. Radiol Phys Technol 2009; 2:1-12. [DOI: 10.1007/s12194-008-0045-y] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2008] [Revised: 10/27/2008] [Accepted: 10/27/2008] [Indexed: 11/25/2022]
|
38
|
Steinke MF, Bezak E. Technological approaches to in-room CBCT imaging. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2008; 31:167-79. [PMID: 18946974 DOI: 10.1007/bf03179341] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The use of Cone-Beam Computed Tomography (CBCT) in Image-Guided Radiation Therapy (IGRT) has become increasingly feasible and popular in recent years. Advances and developments in Flat-Panel Imager (FPI) technology and image reconstruction software allow for linac-mounted 3D CBCT imaging. Taking CBCT images on a daily/weekly basis, offers the possibility to guide the treatment beam according to tumour motion and to apply changes to the treatment plan if necessary. This however raises the issue of additional imaging dose and thus increases in secondary cancer risk. The performance characteristics of kV-CBCT and MV-CBCT solutions currently offered by Elekta, Siemens and Varian are compared in this paper in terms of additional imaging dose and image quality. The review also outlines applications of CBCT for IGRT and Adaptive Radiotherapy (ART). As CBCT is not the only in-room IGRT platform, helical MV-CT (Tomotherapy) and in-room CT designs are also presented.
Collapse
Affiliation(s)
- M F Steinke
- Department of Physics and Astronomy, University of Heidelberg, Germany.
| | | |
Collapse
|
39
|
Gu J, Bednarz B, Xu XG, Jiang SB. Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapy. RADIATION PROTECTION DOSIMETRY 2008; 131:431-443. [PMID: 18667400 DOI: 10.1093/rpd/ncn200] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A Monte Carlo based computational procedure for determining organ doses and effective doses has been described for two procedures used in newly developed image-guided radiation treatment: kilovoltage cone-beam computed tomography (kV CBCT) and mega-voltage computed tomography (MV CBCT). A whole-body patient computational phantom, VIP-Man phantom, is employed for Monte Carlo dose calculations. Results indicate that the thyroid dose is always the highest in head and neck (H&N) scan for both kV and MV CBCT, and the bladder dose is the highest in prostate scan for both kV and MV CBCT. For the VIP-Man phantom, it has been found that the effective dose for kV CBCT (assuming a total exposure of 1350 mAs) is approximately 9.5 mSv for the two anatomical sites, whereas the effective dose for MV CBCT (assuming a total of 6 monitor unit) ranges from 5.10 mSv for the H&N case to 8.39 mSv for the prostate scan. The estimated whole-body effective doses allow different imaging procedures to be compared and evaluated.
Collapse
Affiliation(s)
- Jianwei Gu
- Department of Nuclear Engineering and Engineering Physics, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | | | | | | |
Collapse
|
40
|
Chow JCL, Leung MKK, Islam MK, Norrlinger BD, Jaffray DA. Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation. Med Phys 2007; 35:52-60. [DOI: 10.1118/1.2815625] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
41
|
Zhang J, Yin FF. Minimizing image noise in on-board CT reconstruction using both kilovoltage and megavoltage beam projections. Med Phys 2007; 34:3665-73. [DOI: 10.1118/1.2768862] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
42
|
de Boer HCJ, Heijmen BJM. eNAL: An Extension of the NAL Setup Correction Protocol for Effective Use of Weekly Follow-up Measurements. Int J Radiat Oncol Biol Phys 2007; 67:1586-95. [PMID: 17394953 DOI: 10.1016/j.ijrobp.2006.11.050] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2006] [Revised: 11/02/2006] [Accepted: 11/03/2006] [Indexed: 11/28/2022]
Abstract
PURPOSE The no action level (NAL) protocol reduces systematic displacements relative to the planning CT scan by using the mean displacement of the first few treatment fractions as a setup correction in all subsequent fractions. This approach may become nonoptimal in case of time trends or transitions in the systematic displacement of a patient. Here, the extended NAL (eNAL) protocol is introduced to cope with this problem. METHODS AND MATERIALS The initial setup correction of eNAL is the same as in NAL. However, in eNAL, additional weekly follow-up measurements are performed. The setup correction is updated after each follow-up measurement based on linear regression of the available measured displacements to track and correct systematic time-dependent changes. We investigated the performance of eNAL with Monte Carlo simulations for populations without systematic displacement changes over time, with large gradual changes (time trends), and with large sudden changes (transitions). Weekly follow-up measurements were simulated for 35 treatment fractions. We compared the outcome of eNAL with NAL and optimized shrinking action level (SAL) protocol with weekly measurements. RESULTS Without time-dependent changes, eNAL, SAL, and NAL performed comparably, but SAL required the largest imaging workload. For time trends and transitions, eNAL performed superiorly to the other protocols and reduced systematic displacements to the same magnitude as in case of no time-dependent changes (SD approximately 1 mm). CONCLUSION Extended NAL can reduce systematic displacements to a minor level irrespective of the precise nature of the systematic time-dependent changes that may occur in a population.
Collapse
Affiliation(s)
- Hans C J de Boer
- Division of Medical Physics, Department of Radiation Oncology, Erasmus MC-Daniel den Hoed Cancer Center, Rotterdam, The Netherlands.
| | | |
Collapse
|
43
|
Abstract
Image-guided radiation therapy is an exciting new area that focuses heavily on the potential benefit of advanced imaging and image registration to improve precision, thus limiting morbidity and potentially allowing for safe delivery of increased dose. This review explores the issues surrounding the use of imaging and image registration for treatment planning and verification, with emphasis on the underlying patient model and alignment algorithms.
Collapse
Affiliation(s)
- James M Balter
- Department of Radiation Oncology, The University of Michigan, UH B2C432 Box 0010, 1500 East Medical Center Dr, Ann Arbor, MI 48109, USA.
| | | |
Collapse
|
44
|
Abstract
Imaging is central to radiation oncology practice, with advances in radiation oncology occurring in parallel to advances in imaging. Targets to be irradiated and normal tissues to be spared are delineated on computed tomography (CT) scans in the planning process. Computer-assisted design of the radiation dose distribution ensures that the objectives for target coverage and avoidance of healthy tissue are achieved. The radiation treatment units are now recognized as state-of-the-art robotics capable of three-dimensional soft tissue imaging immediately before, during, or after radiation delivery, improving the localization of the target at the time of radiation delivery, to ensure that radiation therapy is delivered as planned. Frequent imaging in the treatment room during a course of radiation therapy, with decisions made on the basis of imaging, is referred to as image-guided radiation therapy (IGRT). IGRT allows changes in tumor position, size, and shape to be measured during the course of therapy, with adjustments made to maximize the geometric accuracy and precision of radiation delivery, reducing the volume of healthy tissue irradiated and permitting dose escalation to the tumor. These geometric advantages increase the chance of tumor control, reduce the risk of toxicity after radiotherapy, and facilitate the development of shorter radiotherapy schedules. By reducing the variability in delivered doses across a population of patients, IGRT should also improve interpretation of future clinical trials.
Collapse
Affiliation(s)
- Laura A Dawson
- Radiation Medicine Program, Princess Margaret Hospital, University of Toronto, Toronto, ON, Canada.
| | | |
Collapse
|
45
|
Zeidan OA, Langen KM, Meeks SL, Manon RR, Wagner TH, Willoughby TR, Jenkins DW, Kupelian PA. Evaluation of image-guidance protocols in the treatment of head and neck cancers. Int J Radiat Oncol Biol Phys 2007; 67:670-7. [PMID: 17197123 DOI: 10.1016/j.ijrobp.2006.09.040] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2006] [Revised: 09/20/2006] [Accepted: 09/26/2006] [Indexed: 10/23/2022]
Abstract
PURPOSE The aim of this study was to assess the residual setup error of different image-guidance (IG) protocols in the alignment of patients with head and neck cancer. The protocols differ in the percentage of treatment fractions that are associated with image guidance. Using data from patients who were treated with daily IG, the residual setup errors for several different protocols are retrospectively calculated. METHODS AND MATERIALS Alignment data from 24 patients (802 fractions) treated with daily IG on a helical tomotherapy unit were analyzed. The difference between the daily setup correction and the setup correction that would have been made according to a specific protocol was used to calculate the residual setup errors for each protocol. RESULTS The different protocols are generally effective in reducing systematic setup errors. Random setup errors are generally not reduced for fractions that are not image guided. As a consequence, if every other treatment is image guided, still about 11% of all treatments (IG and not IG) are subject to three-dimensional setup errors of at least 5 mm. This frequency increases to about 29% if setup errors >3 mm are scored. For various protocols that require 15% to 31% of the treatments to be image guided, from 50% to 60% and from 26% to 31% of all fractions are subject to setup errors >3 mm and >5 mm, respectively. CONCLUSION Residual setup errors reduce with increasing frequency of IG during the course of external-beam radiotherapy for head-and-neck cancer patients. The inability to reduce random setup errors for fractions that are not image guided results in notable residual setup errors.
Collapse
Affiliation(s)
- Omar A Zeidan
- Department of Radiation Oncology, M. D. Anderson Cancer Center Orlando, Orlando, FL 32806, USA.
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Ding GX, Duggan DM, Coffey CW. Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy. Phys Med Biol 2007; 52:1595-615. [PMID: 17327651 DOI: 10.1088/0031-9155/52/6/004] [Citation(s) in RCA: 91] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The purpose of this investigation is to characterize the beams produced by a kilovoltage (kV) imager integrated into a linear accelerator (Varian on-board imager integrated into the Trilogy accelerator) for acquiring high resolution volumetric cone-beam computed tomography (CBCT) images of the patient on the treatment table. The x-ray tube is capable of generating photon spectra with kVp values between 40 and 125 kV. The Monte Carlo simulations were used to study the characteristics of kV beams and the properties of imaged target scatters. The Monte Carlo results were benchmarked against measurements, and excellent agreements were obtained. We also studied the effect of including the electron impact ionization (EII), and the simulation showed that the characteristic radiation is increased significantly in the energy spectra when EII is included. Although only slight beam hardening is observed in the spectra of all photons after passing through the phantom target, there is a significant difference in the spectra and angular distributions between scattered and primary photons. The results also show that the photon fluence distributions are significantly altered by adding bow tie filters. The results indicate that a combination of large cone-beam field size and large imaged target significantly increases scatter-to-primary ratios for photons that reach the detector panel. For phantoms 10 cm, 20 cm and 30 cm thick of water placed at the isocentre, the scatter-to-primary ratios are 0.94, 3.0 and 7.6 respectively for an open 125 kVp CBCT beam. The Monte Carlo simulations show that the increase of the scatter is proportional to the increase of the imaged volume, and this also applies to scatter-to-primary ratios. This study shows both the magnitude and the characteristics of scattered x-rays. The knowledge obtained from this investigation may be useful in the future design of the image detector to improve the image quality.
Collapse
Affiliation(s)
- George X Ding
- Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN 37232-5671, USA.
| | | | | |
Collapse
|
47
|
Nishio T, Kunieda E, Shirato H, Ishikura S, Onishi H, Tateoka K, Hiraoka M, Narita Y, Ikeda M, Goka T. Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403). Phys Med Biol 2006; 51:5409-17. [PMID: 17047260 DOI: 10.1088/0031-9155/51/21/002] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to minimize the variations of the prescription dose between the institutions. We visited the 16 participating institutions and examined the absolute dose at the centre of a simulated spherical tumour of 3.0 cm diameter in the lung using the radiation treatment planning systems in each institution. A lung phantom for stereotactic body radiotherapy (SBRT) was developed and used for the treatment planning and film dosimetry. In the JCOG radiotherapy study group, the no model-based calculation algorithm or the model-based calculation algorithm with a dose kernel unscaled for heterogeneities were selected for use in the initial SBRT trials started in 2004, and the model-based calculation algorithm with a dose kernel scaled for heterogeneities was selected for the coming trial. The findings of this study suggest that the clinical results of lung SBRT trials should be carefully evaluated in comparison with the actual dose given to patients.
Collapse
Affiliation(s)
- Teiji Nishio
- Radiation Oncology Division, National Cancer Center Hospital East, Kashiwa, Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Abstract
Technological advances have greatly enhanced the specialty of radiation oncology by allowing more healthy tissue to be spared for the same or better tumour coverage. Developments in medical imaging are integral to radiation oncology, both for design of treatment plans and to localise the target for precise administration of radiation. At planning, definition of the tumour and healthy tissue is based on CT, augmented frequently with MRI and PET. At treatment, three-dimensional soft-tissue imaging can also be used to localise the target and tumour motion can be tracked with fluoroscopic imaging of radio-opaque markers implanted in or near the tumour. These developments allow changes in tumour position, size, and shape that take place during radiotherapy to be measured and accounted for to boost geometric accuracy and precision of radiation delivery. Image-guided treatment also enhances uniformity in doses administered in a population of patients, thus improving our ability to measure the effect of dosimetric and non-dosimetric factors on tumour and healthy tissue outcomes in clinical trials. Increased precision and accuracy of radiotherapy are expected to augment tumour control, reduce incidence and severity of toxic effects after radiotherapy, and facilitate development of more efficient shorter schedules than currently available.
Collapse
Affiliation(s)
- Laura A Dawson
- Department of Radiation Oncology, Princess Margaret Hospital, University of Toronto, 610 University Ave, Toronto, ON, Canada M5G 2M9.
| | | |
Collapse
|
49
|
Abstract
Accurate patient setup and target localization are essential to advanced radiation therapy treatment. Significant improvement has been made recently with the development of image-guided radiation therapy, in which image guidance facilitates short treatment course and high dose per fraction radiotherapy, aiming at improving tumor control and quality of life. Many imaging modalities are being investigated, including x-ray computed tomography (CT), ultrasound imaging, positron emission tomography, magnetic resonant imaging, magnetic resonant spectroscopic imaging, and kV/MV imaging with flat panel detectors. These developments provide unique imaging techniques and methods for patient setup and target localization. Some of them are different; some are complementary. This paper reviews the currently available kV x-ray CT systems used in the radiation treatment room, with a focus on the CT-on-rails systems, which are diagnostic CT scanners moving on rails installed in the treatment room. We will describe the system hardware including configurations, specifications, operation principles, and functionality. We will review software development for image fusion, structure recognition, deformation correction, target localization, and alignment. Issues related to the clinical implementation of in-room CT techniques in routine procedures are discussed, including acceptance testing and quality assurance. Clinical applications of the in-room CT systems for patient setup, target localization, and adaptive therapy are also reviewed for advanced radiotherapy treatments.
Collapse
|
50
|
de Crevoisier R, Kuban D, Lefkopoulos D. Radiothérapie guidée par tomodensitométrie associée à l'accélérateur linéaire dans la salle de traitement. Cancer Radiother 2006; 10:245-51. [PMID: 16959518 DOI: 10.1016/j.canrad.2006.06.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/08/2006] [Indexed: 11/20/2022]
Abstract
Target localization has become increasingly important in the advent of IMRT, as treatment margins are reduced and target doses are increased with high-dose gradients outside this target volume. The in-room CT on rails-LINAC system allows CT imaging while the patient remains immobilized in the treatment position just prior to treatment. The anatomic inter- and intra-fractional variations can be therefore quantified during a course of treatment. The position of the tumour can be checked and corrected before the fraction. In case of modification of tumour shape, a re-planning of the treatment is also feasible. However, several issues remain: the integration with routine clinical treatment due to a lack of software tools, the frequency of imaging, and the cost-efficiency ratio. The clinical experience is yet very limited but CT-image-guided radiotherapy appears promising for prostate, brain and spinal tumours.
Collapse
Affiliation(s)
- R de Crevoisier
- Département de radiothérapie, institut Gustave-Roussy, 39, rue Camille-Desmoulins, 94805 Villejuif, France
| | | | | |
Collapse
|