1
|
Mallik AK, Qiu H, Takafuji M, Ihara H. Selectivity enhancement for the separation of tocopherols and steroids by integration of highly ordered weak interaction sites along the polymer main chain. Anal Bioanal Chem 2012; 404:229-38. [DOI: 10.1007/s00216-012-6098-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2011] [Revised: 03/19/2012] [Accepted: 05/02/2012] [Indexed: 10/28/2022]
|
2
|
Complete chromatographic separation of steroids, including 17α and 17β-estradiols, using a carbazole-based polymeric organic phase in both reversed and normal-phase HPLC. Anal Bioanal Chem 2010; 397:623-9. [DOI: 10.1007/s00216-010-3601-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2010] [Accepted: 02/19/2010] [Indexed: 10/19/2022]
|
3
|
Toledo-Pinto E, Menezes M, Pereira O. Desenvolvimento de um método analítico rápido e eficiente para a determinação de corticosteróides plasmáticos por injeção direta em coluna cromatográfica ISRP-C18 por CLAE. ECLÉTICA QUÍMICA 2010. [DOI: 10.1590/s0100-46702010000200006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
O presente trabalho teve como objetivo o desenvolvimento de um método analítico simples, rápido e eficiente para a determinação de corticosteróides (cortisona, corticosterona, acetato de hidrocortisona e acetato de dexametasona) em amostras sangüíneas de ratos empregando um sistema isocrático de cromatografia líquida de alta eficiência (CLAE) com detecção ultravioleta. O método envolveu a injeção direta da amostra sangüínea em uma coluna cromatográfica com superfície interna de fase reversa (ISRP-C18), empregando a fase móvel composta por tampão fosfato pH 4,0: acetonitrila (65:35 v/v). A detecção dos analitos foi obtida, através de um detector de ultravioleta de comprimento de onda variável (Varian Modelo 2550) ajustado em 240 nm e um integrador SP 4400 Chromaject (Varian Associates, Inc, Sunnyvale, CA, USA). A extração do analito resultou em valores de recuperação entre 90% e 108%, e coeficiente de variação entre 1,1% a 2,5%. Os limites de detecção e quantificação do método foram de 0,02 e 0,04 µg mL-1, respectivamente. Assim, o método analítico proposto possibilitou a injeção direta (on-line) da amostra sem tratamento prévio apresentando também várias vantagens, tais como: rapidez, exatidão, precisão e especificidade.
Collapse
|
4
|
Destrez B, Bichon E, Rambaud L, Courant F, Monteau F, Pinel G, Antignac JP, Le Bizec B. Criteria to distinguish between natural situations and illegal use of boldenone, boldenone esters and boldione in cattle 2. Direct measurement of 17beta-boldenone sulpho-conjugate in calf urine by liquid chromatography--high resolution and tandem mass spectrometry. Steroids 2009; 74:803-8. [PMID: 19409402 DOI: 10.1016/j.steroids.2009.04.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2009] [Revised: 04/17/2009] [Accepted: 04/20/2009] [Indexed: 10/20/2022]
Abstract
Boldenone is banned in the European Union (Directive 96/22/EC) as growth promoter for meat producing animals. Boldione (ADD), boldenone and boldenone esters (mainly the undecylenate form) are commercially available as anabolic preparations, either to the destination of human, horse or cattle. Since the late 90s, the natural occurrence of boldenone metabolites has been reported in cattle. According to EU regulation, the unambiguous demonstration of boldenone administration in bovine urine should be provided on the basis of boldenone identification in the corresponding conjugate fraction. An analytical method has been developed and validated according to current standards with main concern to the measurement of intact 17beta-boldenone-sulphate. The analytical procedure included direct extraction-purification of target analyte on octadecylsilyl cartridges and direct detection of phase II metabolite by liquid chromatography (negative electrospray), tandem mass spectrometry (QqQ) or high resolution mass spectrometry (Orbitrap). Decision limit (CCalpha) and detection capability (CCbeta) were respectively 0.2 microg L(-1) and 0.4 microg L(-1) on triple quadrupole and 0.1 microg L(-1) and 0.2 microg L(-1) on hybrid system. The method was successfully applied to the analysis of incurred samples collected in different experiments. 17beta-Boldenone-sulphate was measurable up to 36h after oral administration of boldione, and 30 days after 17beta-boldenone undecylenate intra-muscular injection. This conjugate form was never detected in non-treated animals, confirming its status of definitive candidate marker for boldenone administration in calf.
Collapse
Affiliation(s)
- Blandine Destrez
- Laboratoire d'Etude des Résidus et Contaminants dans les Aliments (LABERCA), Ecole Nationale Vétérinaire de Nantes (ENVN), BP 50707, Route de Gachet, 44307 Nantes Cedex 3, France
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Galesio M, Rial-Otero R, Capelo-Martínez JL. Comparative study of matrices for their use in the rapid screening of anabolic steroids by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:1783-1791. [PMID: 19444857 DOI: 10.1002/rcm.4074] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
New data on sample preparation and matrix selection for the fast screening of androgenic anabolic steroids (AAS) by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF-MS) is presented. The rapid screening of 15 steroids included in the World Anti-Doping Agency (WADA) prohibited list using MALDI was evaluated. Nine organic and two inorganic matrices were assessed in order to determine the best matrix for steroid identification in terms of ionisation yield and interference by characteristic matrix ions. The best results were achieved for the organic matrices 2-(4-hydroxyphenylazo)benzoic acid (HABA) and trans-3-indoleacrylic acid (IAA). Good signals for all the steroids studied were obtained for concentrations as low as 0.010 and 0.050 microg/mL on the MALDI sample plate for the HABA and IAA matrices, respectively. For these two matrices, the sensitivity achieved by MALDI is comparable with the sensitivity achieved by gas chromatography/mass spectrometry (GC/MS), which is the conventional technique used for AAS detection. Furthermore, the accuracy and precision obtained with MALDI are very good, since an internal mass calibration is performed with the matrix ions. For the inorganic matrices, laser fluences higher than those used with organic matrices are required to obtain good MALDI signals. When inorganic matrices were used in combination with glycerol as a dispersing agent, an important reduction of the background noise was observed. Urine samples spiked with the study compounds were processed by solid-phase extraction (SPE) and the screening was consistently positive.
Collapse
Affiliation(s)
- M Galesio
- REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnología, Universidade Nova de Lisboa, 2829-516 Monte de Caparica, Portugal
| | | | | |
Collapse
|
6
|
Sirén H, Seppänen-Laakso T, Orešič M. Capillary electrophoresis with UV detection and mass spectrometry in method development for profiling metabolites of steroid hormone metabolism. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 871:375-82. [DOI: 10.1016/j.jchromb.2008.06.016] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2008] [Revised: 06/02/2008] [Accepted: 06/06/2008] [Indexed: 11/30/2022]
|
7
|
Chen HX, Zhang XX. Antibody development to testosterone and its application in capillary electrophoresis-based immunoassay. Electrophoresis 2008; 29:3406-13. [DOI: 10.1002/elps.200700660] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
8
|
Muñiz‐Valencia R, Ceballos‐Magaña SG, Gonzalo‐Lumbreras R, Santos‐Montes A, Izquierdo‐Hornillos RC. Sample preparation for the determination of steroids (corticoids and anabolics) in feed using LC. J Sep Sci 2008; 31:2303-9. [DOI: 10.1002/jssc.200800025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
9
|
Muñiz-Valencia R, Gonzalo-Lumbreras R, Santos-Montes A, Izquierdo-Hornillos R. Liquid chromatographic method development for anabolic androgenic steroids using a monolithic column. Anal Chim Acta 2008; 611:103-12. [DOI: 10.1016/j.aca.2008.01.057] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2007] [Revised: 01/24/2008] [Accepted: 01/25/2008] [Indexed: 10/22/2022]
|
10
|
Silva CA, Pereira EA, Micke GA, Farah JPS, Tavares MFM. Mixture-designed electrolytes for the MEKC separation of natural and synthetic steroids. Electrophoresis 2008; 28:3722-30. [PMID: 17941121 DOI: 10.1002/elps.200700511] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In this work, the separation of 11 natural and synthetic steroids was studied using MEKC electrolytes modified by property-selected organic solvents: ethanol, ACN, and THF. The interplay between electrophoretic behavior and structural features was disclosed and the effects of organic modifiers to modulate retention and to alter selectivity were discussed in terms of system linear solvation energy relationships (LSER). The LSER indicated the total organic solvent percentage in the electrolyte as a major parameter to control retention and as a minor contribution, the hydrogen bond acidity. By evaluating the electropherograms obtained from mixture-designed electrolytes, a favorable separation condition for all solutes was achieved in ca. 25 min with an electrolyte composed of 20 mmol/L sodium tetraborate at pH 9.4, 20 mmol/L SDS and 20% EtOH (0.80% CV for migration time and 2.5% CV for peak area, n = five consecutive injections). The applicability of the proposed separation condition was demonstrated by the inspection of estrogens in urine sample (puberty stage).
Collapse
Affiliation(s)
- Claudinei A Silva
- Institute of Chemistry, University of São Paulo, São Paulo, SP, Brazil
| | | | | | | | | |
Collapse
|
11
|
Xiao KP, Xiong Y, Liu FZ, Rustum AM. Efficient method development strategy for challenging separation of pharmaceutical molecules using advanced chromatographic technologies. J Chromatogr A 2007; 1163:145-56. [PMID: 17628579 DOI: 10.1016/j.chroma.2007.06.027] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2007] [Revised: 04/17/2007] [Accepted: 06/18/2007] [Indexed: 10/23/2022]
Abstract
In this paper, we describe a strategy that can be used to efficiently develop a high-performance liquid chromatography (HPLC) separation of challenging pharmaceutical molecules. This strategy involves use of advanced chromatographic technologies, such as a computer-assisted chromatographic method development tool (ChromSword) and an automated column switching system (LC Spiderling). This process significantly enhances the probability of achieving adequate separations and can be a large time saver for bench analytical scientists. In our study, the ChromSword was used for mobile phase screening and separation optimization, and the LC Spiderling was used to identify the most appropriate HPLC columns. For proof of concept, the analytes employed in this study are the structural epimers betamethylepoxide and alphamethylepoxide (also known as 16-beta methyl epoxide and 16-alpha methyl epoxide). Both of these compounds are used in the synthesis of various active pharmaceutical ingredients that are part of the steroid pharmaceutical products. While these molecules are relatively large in size and contain various polar functional groups and non-polar cyclic carbon chains, their structures differ only in the orientation of one methyl group. To our knowledge, there is no reported HPLC separation of these two molecules. A simple gradient method was quickly developed on a 5 cm YMC Hydrosphere C(18) column that separated betamethylepoxide and alphamethylepoxide in 10 min with a resolution factor of 3.0. This high resolution provided a true baseline separation even when the concentration ratio between these two epimers was 10,000:1. Although outside of the scope of this paper, stability-indicating assay and impurity profile methods for betamethylepoxide and for alphamethylepoxide have also been developed by our group based on a similar method development strategy.
Collapse
Affiliation(s)
- Kang Ping Xiao
- Global Quality Services - Analytical Sciences, Schering-Plough Corporation, Union, NJ 07083, USA
| | | | | | | |
Collapse
|
12
|
Pappa-Louisi A, Nikitas P, Papageorgiou A. Optimisation of multilinear gradient elutions in reversed-phase liquid chromatography using ternary solvent mixtures. J Chromatogr A 2007; 1166:126-34. [PMID: 17720170 DOI: 10.1016/j.chroma.2007.08.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2007] [Revised: 08/03/2007] [Accepted: 08/07/2007] [Indexed: 11/17/2022]
Abstract
The multilinear gradient elution theory for binary mobile phases in reversed-phase liquid chromatography presented in [P. Nikitas, A. Pappa-Louisi, A. Papageorgiou, J. Chromatogr. A 1157 (2007) 178] is extended to ternary gradients. For the evaluation of this theory and the performance of the various fitting and optimisation algorithms we used 13 o-phthalaldehyde (OPA) derivatives of amino acids with mobile phases modified by acetonitrile and methanol. It is shown that the theory can lead to high quality predictions of the retention times under gradients elutions and optimisation of ternary gradients provided that we use a six-parameter expression for the logarithm of the retention factor, lnk, and the adjustable parameters of this expression are determined from ternary isocratic data.
Collapse
Affiliation(s)
- A Pappa-Louisi
- Laboratory of Physical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
| | | | | |
Collapse
|
13
|
Amundsen LK, Nevanen TK, Takkinen K, Rovio S, Sirén H. Microscale immunoaffinity SPE and MEKC in fast determination of testosterone in male urine. Electrophoresis 2007; 28:3232-41. [PMID: 17722186 DOI: 10.1002/elps.200700037] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Conventional methods for the determination of testosterone in body fluids typically suffer from poor recovery, lack of specificity, complex sample pretreatment, or the need for derivatization. Here, a simple, specific, and fast analysis method for testosterone was developed, with a methodology based on testosterone-specific immunoaffinity SPE (IA-SPE) and subsequent analysis by partial filling MEKC (PF-MEKC). An immunosorbent consisting of a recombinant antitestosterone Fab fragment covalently attached to activated Sepharose was prepared. IA-SPE and PF-MEKC were set up in hyphenated and off-line constructions, and the applicability of the two constructions in analysis of testosterone in male urine was investigated. The results obtained with the hyphenated construction proved to be only indicative of the presence of testosterone. The off-line IA-SPE and PF-MEKC construction, however, was successfully used in the determination of free testosterone in male urine samples after enzymatic hydrolysis of the glucuronide conjugates. Except for the hydrolysis reaction, no sample pretreatment was required. After hydrolysis, the overall analysis time per sample was only 14 min. The off-line IA-SPE and PF-MEKC method proved to be robust, sensitive (LOQ 35 mug/L), and specific, enabling separation of testosterone from four related steroids. Thus, it provides attractive features when compared to traditional methods for determination of testosterone in male urine.
Collapse
|
14
|
Gonzalo-Lumbreras R, Muñiz-Valencia R, Santos-Montes A, Izquierdo-Hornillos R. Liquid chromatographic method development for steroids determination (corticoids and anabolics). J Chromatogr A 2007; 1156:321-30. [PMID: 17451720 DOI: 10.1016/j.chroma.2007.01.095] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2006] [Revised: 01/18/2007] [Accepted: 01/23/2007] [Indexed: 11/24/2022]
Abstract
A LC isocratic separation study of a complex mixture containing 18 steroids (corticoids and anabolics), used potentially as growth promoters, was carried out. For this purpose, using a Hypersil ODS column at controlled temperature, mobile phases (from binary to quaternary) prepared from water and MeOH, ACN or THF as organic modifiers and UV detection at 245 nm, were employed (dehydroepiandrosterone was detected at 200 nm). The optimum separation was achieved using water/acetonitrile (65:35, v/v) as mobile phase at 30 degrees C, allowing the separation of 16 out of 18 steroids in about 30 min. The retention scale using optimized binary mobile phases was related with steroids hydrophobicity and structure, allowing a classification into three groups for these compounds. To improve the separation several alkyl-silica packings were tested: Type A (Lichrospher C8) and Type B (Luna C18, Kromasil C18, Purospher C18 and Synergy C12). Taking into account resolution, number of separated compounds and run time analysis the Hypersil column was selected as the best choice for further applications. Calibration graphs were obtained using fluorocortisone, fluoxymesterone or methylprednisolone as internal standard. The optimized separation was applied to the analysis of piglet feed samples spiked with steroids. The sample preparation process included solvent extraction using diethyleter and solid phase extraction using silica cartridges. The recoveries were in the range 70-92%. Decision limits and detection capability were in the range 34-198 and 41-249 microg/kg, respectively. Repeatability was also evaluated.
Collapse
Affiliation(s)
- R Gonzalo-Lumbreras
- Departamento de Química Analítica, Facultad de Ciencias Químicas, Universidad Complutense, 28040 Madrid, Spain
| | | | | | | |
Collapse
|
15
|
Xiao KP, Chien D, Markovich R, Rustum AM. Development and validation of a stability-indicating reversed-phase high performance liquid chromatography method for assay of betamethylepoxide and estimation of its related compounds. J Chromatogr A 2007; 1157:207-16. [PMID: 17512937 DOI: 10.1016/j.chroma.2007.05.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2007] [Revised: 04/30/2007] [Accepted: 05/02/2007] [Indexed: 10/23/2022]
Abstract
Betamethylepoxide (16beta-methyl-Delta(1,4)-pregnadiene-9beta-11beta-oxide-17alpha,21-diol-3,20-dione) is a key intermediate for the synthesis of various active pharmaceutical ingredients (APIs) of steroid compounds. A stability-indicating reversed-phase HPLC method for assay of betamethylepoxide and estimation of its related compounds has been developed and validated. This method can accurately quantitate betamethylepoxide in the presence of numerous structurally related compounds (including the alpha-epimer, known as alphamethylepoxide). This method can also adequately separate most of the impurities from each other and estimate their quantities in betamethylepoxide samples. The stability-indicating capability of this method has been demonstrated by adequate separation of the degradation products from betamethylepoxide in stress degraded and aged stability samples. The HPLC column used in the method was a 5 cm YMC Hydrosphere C(18) column (4.6 mm I.D.) and the mobile phase consisted of (A) water and (B) acetonitrile:methanol (8:25, v/v).
Collapse
Affiliation(s)
- Kang Ping Xiao
- Global Quality Services-Analytical Sciences, Schering-Plough Corporation, Union, NJ 07083, USA.
| | | | | | | |
Collapse
|
16
|
Amundsen LK, Sirén H. Partial filling micellar electrokinetic chromatography analysis of androgens and testosterone derivatives using two sequential pseudostationary phases. J Chromatogr A 2006; 1131:267-74. [PMID: 16949594 DOI: 10.1016/j.chroma.2006.07.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2006] [Revised: 06/16/2006] [Accepted: 07/10/2006] [Indexed: 10/24/2022]
Abstract
Separation of anabolic and androgenic steroids by micellar electrokinetic chromatography (MEKC) has been little studied. Simultaneous separation of the endogenous alpha-epimers testosterone and epitestosterone has not been achieved with any electroseparation technique. Here, a partial filling micellar electrokinetic chromatographic (PF-MEKC) method is described for the analysis of three endogenous steroid hormones (androstenedione, testosterone, epitestosterone) and two synthetic anabolic steroids (fluoxymesterone, methyltestosterone). The resolution efficiency of single-isomer sulphated gamma-cyclodextrins and the surfactants sodium dodecyl sulphate and sodium taurocholate was exploited. The method is based on the sequential introduction of short plugs of two different pseudostationary phases into the capillary. The separation was completed in less than 10 min. The method can be used in quantitative analysis. Linear correlation was obtained between concentration and peak area of 0.996 or better. The repeatability (RSD) of the compound peak areas ranged from 3.6% (methyltestosterone) to 6.2% (androstenedione). Limits of detection were between 73 microg/L (testosterone) and 160 microg/L (fluoxymesterone). As a demonstration of the method, androstenedione, testosterone and epitestosterone were determined in a spiked urine sample.
Collapse
|
17
|
Shen HJ, Lin CH. Comparison of the use of anionic and cationic surfactants for the separation of steroids based on MEKC and sweeping-MEKC modes. Electrophoresis 2006; 27:1255-62. [PMID: 16440398 DOI: 10.1002/elps.200500659] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In attempts to improve the selectivity and sensitivity of steroid separation and to determine their migration order, a comparison of the use of anionic and cationic surfactants based on the MEKC and sweeping-MEKC modes was made. A mixture of six steroids (progesterone, 17-hydroxy progesterone, 11-deoxycortisol, corticosterone, cortisone, and cortisol) could be separated and detected by means of the CE/UV-absorption method. The order of migration time for these steroids was compared under various conditions, including acidic/alkaline buffers, anionic/cationic surfactants, and positive/negative applied voltage, causing the direction of the EOF and the migration of micelles to change. The major rules for generally predicting the migration order of steroids are summarized. The detection limits were significantly improved when the sweeping-MEKC mode was applied.
Collapse
Affiliation(s)
- Hui-Ju Shen
- Department of Chemistry, National Taiwan Normal University, Taipei, Taiwan
| | | |
Collapse
|
18
|
Ceschel G, Bergamante V, Maffei P, Lombardi Borgia S, Calabrese V, Biserni S, Ronchi C. Solubility and transdermal permeation properties of a dehydroepiandrosterone cyclodextrin complex from hydrophilic and lipophilic vehicles. Drug Deliv 2005; 12:275-80. [PMID: 16188726 DOI: 10.1080/10717540500176563] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022] Open
Abstract
The permeation ability of a compound is due principally to its concentration in the vehicle and to its aptitude to cross the stratum corneum of the skin. In this work ex-vivo permeation studies on newly developed formulations containing dehydroepiandrosterone (DHEA) were carried out to investigate vehicles that increase drug permeation through the skin. To enhance the solubility of DHEA, its complex form with alpha-cyclodextrin was used. In addition, the two forms (pure drug and complex form) were introduced in hydrophilic (water), lipophilic (paraffin oil), and microemulsion vehicles to evaluate the synergic effect of cyclodextrins and microemulsion vehicles on solubility and permeation. From the results, DHEA solubility is notably conditioned by the type of the vehicle used: the highest solubilities (both for pure and complex drug forms) were obtained with microemulsion, followed by paraffin oil and water. Moreover, in all the studied vehicles, the c-DHEA was more soluble than DHEA. Permeation profile fluxes showed very interesting differences. That reflect the varying drug forms (pure drug and complex form), vehicles used, and drug concentrations in the vehicles. The major flux was obtained in complex of DHEA with alpha-cyclodextrins in the microemulsion vehicle. Therefore, this type of vehicle and drug form would be very useful in the development of a topical formulation containing DHEA.
Collapse
Affiliation(s)
- GianCarlo Ceschel
- Department of Pharmaceutical Science, University of Bologna, Bologna, Italy.
| | | | | | | | | | | | | |
Collapse
|
19
|
Pappa-Louisi A, Nikitas P, Karageorgaki M. Retention prediction in ternary solvent reversed-phase liquid chromatography systems based on the variation of retention with binary mobile phase composition. J Chromatogr A 2005; 1091:21-31. [PMID: 16395789 DOI: 10.1016/j.chroma.2005.07.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An extension of the treatment adopted in a recent paper [P. Nikitas, A. Pappa-Louisi, P. Agrafiotou, J. Chromatogr. A 946 (2002) 33] was used to derive expressions describing the variation of solute retention k with composition in ternary reversed phase liquid chromatography, RP-LC, solvent systems. The equation of the partition model obtained in this way for a ternary mobile phase was identical to that previously derived using the solubility parameter concept. This equation as well as two new expressions of In k versus organic modifiers content were tested in a variety of ternary solvent systems in order to examine the possibility of predicting retention behavior of solutes under ternary solvent mixture elution conditions from known retention characteristics in binary mobile phases. It was demonstrated the superiority of both new equations derived in this paper to that previously proposed and applied to date in ternary solvent mixtures.
Collapse
Affiliation(s)
- A Pappa-Louisi
- Laboratory of Physical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
| | | | | |
Collapse
|
20
|
Gonzalo-Lumbreras R, García-Miguens MA, Izquierdo-Hornillos R. HPLC method development for testosterone propionate and cipionate in oil-based injectables. J Pharm Biomed Anal 2005; 38:757-62. [PMID: 15967305 DOI: 10.1016/j.jpba.2005.02.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2004] [Revised: 02/03/2005] [Accepted: 02/04/2005] [Indexed: 11/17/2022]
Abstract
Two isocratic liquid chromatographic methods for the determination of testosterone propionate (TP) and cipionate (TC) in oil-based injectables using methyltestosterone and bolasterone as internal standards, respectively, have been developed and validated. Mobile phases 57% water:acetonitrile 43% (v:v) and 54% water:acetonitrile 46% (v:v) were used for TP and TC, respectively. For both methods, a bonded-silica Luna CN (250 mm x 4.6 mm i.d., 5 microm) (25 degrees C) column, a flow-rate 1 ml min(-1) and UV absorbance detection at 245 nm were used and two separations up to base line were achieved. Prior to HPLC analysis, sample preparation was required, including extraction of TP and TC from oil-based injectables using the surfactant sodium dodecyl sulphate.
Collapse
Affiliation(s)
- R Gonzalo-Lumbreras
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense, 28040 Madrid, Spain
| | | | | |
Collapse
|
21
|
Kowalska S, Krupczyńska K, Buszewski B. Some remarks on characterization and application of stationary phases for RP-HPLC determination of biologically important compounds. Biomed Chromatogr 2005; 20:4-22. [PMID: 16041787 DOI: 10.1002/bmc.543] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Biologically active compounds such as vitamins, steroids, nucleosides, peptides and proteins play a very important role in coordinating living organism functions. Determination of those substances is indispensable in pathogenesis. Their complex structure and physico-chemical properties cause many analytical problems. Chromatography is the most common technique used in pharmaceutical and biomedical analysis. The interaction between analyte and stationary phase plays a major role in the separation process. The structure of the packing has a significant influence on the results of the separation process. Various types of spectroscopic techniques, such as nuclear magnetic resonance spectroscopy, infrared spectroscopy, fluorescence spectroscopy and photoacoustic spectroscopy can be useful tools for the characterization of packings. Surface area measurements, elemental analysis, thermal analysis and microcalorimetric measurements are also helpful in this field. Part of the paper contains a description of chromatographic tests used for the determination of column properties. The description of the possibilities of surface characterization is not complete, but is focused on the most popular techniques and practical chromatographic tests. All the presented methods made possible the design and quality control of a new generation stationary phases, which are the future of high-performance liquid chromatography.
Collapse
Affiliation(s)
- Sylwia Kowalska
- Department of Environmental Chemistry and Ecoanalytics, Nicolaus Copernicus University, Faculty of Chemistry, 7 Gagarin St., Pl-87-100 Toruń, Poland
| | | | | |
Collapse
|
22
|
Amundsen LK, Kokkonen JT, Rovio S, Sirén H. Analysis of anabolic steroids by partial filling micellar electrokinetic capillary chromatography and electrospray mass spectrometry. J Chromatogr A 2004; 1040:123-31. [PMID: 15248432 DOI: 10.1016/j.chroma.2004.03.061] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A partial filling micellar electrokinetic capillary chromatography (PF-MEKC) separation of six anabolic androgenic steroids (androstenedione, metandienone, fluoxymesterone, methyltestosterone, 17-epimetandienone and testosterone) is introduced. The method utilises a mixed micellar solution consisting of sodium dodecyl sulphate (SDS) and sodium taurocholate. The analytes are detected with a photodiode array detector at 247 nm wavelength. Methyltestosterone is used as internal standard. The detection limits were 39 microg/L for androstenedione, 40 microg/L for testosterone, 45 microg/L for fluoxymesterone, 45-90 microg/L for 17-epimetandienone, 59 microg/L for methyltestosterone and 90 microg/L for metandienone. Linear correlation between concentration (0.1-5.0 mg/L) and detector response was obtained with r2 of 0.994 for fluoxymesterone, 0.998 for 17-epimetandienone and 0.999 for androstenedione, metandienone and testosterone. In addition, ionisation of the investigated compounds in electrospray mass spectrometry (ESI-MS) was studied in positive ion mode. The most intense signal (100%) was the protonated molecular ion [M + H]+, except for 17-epimetandienone, which gave its strongest signal at m/z corresponding to [M - H2O + H]+. Finally, separation and identification of fluoxymesterone, androstenedione and testosterone by PF-MEKC-ESI-MS is described. This is the first use of PF-MEKC and PF-MEKC-ESI-MS assays for anabolic androgenic steroids.
Collapse
|
23
|
Gonzalo-Lumbreras R, Izquierdo-Hornillos R. Method development for corticosteroids and anabolic steroids by micellar liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 794:215-25. [PMID: 12954374 DOI: 10.1016/s1570-0232(03)00426-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A systematic optimization of the HPLC separation of a complex mixture containing urinary steroids (anabolics and corticoids), boldenone and bolasterone (synthetic anabolics) by micellar liquid chromatography has been carried out. The isocratic micellar mobile phases (from binary to quaternary) consisted of sodium dodecyl sulphate and organic modifiers such as acetonitrile, tetrahydrofuran, propanol, butanol or pentanol. The effect of the organic modifiers, surfactant concentration, temperature, ionic strength and flow-rate on the separation has been studied. A micellar mobile phase made of 5% propanol and 40 mM surfactant allowed the separation of 13 steroids in about 23 min. A bivariant optimization method for the micellar mobile phase surfactant-propanol corroborated the above results. The separations obtained show good perspectives for future developments.
Collapse
Affiliation(s)
- R Gonzalo-Lumbreras
- Faculty of Chemistry, Universidad Complutense de Madrid, E-28040 Madrid, Spain
| | | |
Collapse
|
24
|
Gonzalo-Lumbreras R, Izquierdo-Hornillos R. Conventional and micellar liquid chromatography method development for danazol and validation in capsules. J Pharm Biomed Anal 2003; 32:433-9. [PMID: 14565547 DOI: 10.1016/s0731-7085(03)00224-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Two isocratic liquid chromatographic methods (conventional and micellar) for the determination of danazol (DZ) in capsules using canrenone (CAN) as internal standard have been developed and validated. In conventional liquid chromatography a mobile phase 35% water:acetonitrile 65%, v:v, a flow-rate 1 ml min(-1) and a C18 Hypersil ODS (250 x 4.6 mm, 5 microm) column (25 degrees C) were used. In micellar liquid chromatography (MLC) the conditions were: mobile phase 40 mM sodium dodecyl sulfate:2% pentanol, flow-rate 0.5 ml min(-1) and C18 Hypersil ODS (150 x 3.0 mm, 5 microm) column (60 degrees C). For both methods. UV absorbance detection at 280 nm was used and a separation up to base line was achieved. Prior to HPLC analysis a simple sample preparation was required. The recoveries found in the accuracy test were 99 +/- 10 and 101 +/- 8%, in conventional liquid chromatography (CLC) and MLC, respectively. Repeatability and intermediate precision expressed as R.S.D. were lower than 5% for both methods. Detection limits obtained were 2.4 and 3.0 ng g(-1) in CLC and CLM, respectively.
Collapse
Affiliation(s)
- R Gonzalo-Lumbreras
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense, Ciudad Universitaria, Madrid, Spain
| | | |
Collapse
|
25
|
Shu PY, Chou SH, Lin CH. Determination of corticosterone in rat and mouse plasma by gas chromatography-selected ion monitoring mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 783:93-101. [PMID: 12450528 DOI: 10.1016/s1570-0232(02)00520-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A simple, highly sensitive and specific method based on gas-chromatography-selected ion monitoring (SIM) mass spectrometry has been developed for the quantitation of corticosterone in rat and mouse plasma. After extraction of the plasma with ethyl acetate, the residue was trimethy-silylated with pentafluorobenzyl hydroxylamine-trimethylsilyl (PFBO-TMS). Detection of the derivatives was accomplished by a quadruple mass spectrometer in the selected ion monitoring mode (m/z of 316, 648, 663 and 678). The detection limit of the assay was 0.1 pg on column. The results show that in the plasma of non-stressed animals, only minor amounts of corticosterone were found; whereas in the plasma of stressed animals, it was dramatically increased. The method developed here can be used to examine corticosterone levels as a marker of stress in rats and mice and may also be used for estimation of the effect of stress-release medications.
Collapse
Affiliation(s)
- Pin Yen Shu
- Department of Chemistry, National Taiwan Normal University, 88 Sec. 4, Tingchow Road, Taipei, Taiwan
| | | | | |
Collapse
|
26
|
Ceschel GC, Mora PC, Lombardi Borgia S, Maffei P, Ronchi C. Skin permeation study of dehydroepiandrosterone (DHEA) compared with its alpha-cyclodextrin complex form. J Pharm Sci 2002; 91:2399-407. [PMID: 12379925 DOI: 10.1002/jps.10229] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Several studies have shown that dehydroepiandrosterone (DHEA) has promising uses in a large range of pathologies including age-related illnesses (osteoporosis, atherosclerosis), immune dysfunctions, and cancer. A long-term oral dosage form would be favorable, but this type of medication has not been developed yet because of the important first-pass effect and low and variable bioavailability. A proposed alternative strategy is the preparation of DHEA for transdermal permeation, allowing direct absorption in the systemic circulation. DHEA has shown good permeation properties through the stratum corneum, however its poor water solubility limits its dosage form concentration and represents the major obstacle to the formulation of a reservoir transdermal system. However, alpha-cyclodextrins have been shown to improve the solubility, the dissolution properties, and the partition coefficient of DHEA. This paper deals with the formulation and evaluation of a transdermal gel containing an alpha-cyclodextrin complex with DHEA. In in vitro permeation tests on porcine skin, the formulation containing the complex improved the permeation flux of DHEA. The study also shows that a gel formulation improved drug permeation with respect to simple water suspension.
Collapse
Affiliation(s)
- Gian Carlo Ceschel
- Dipartimento di Scienze Farmaceutiche, Università di Bologna, via San Donato 19/2, 40100 Bologna, Italy
| | | | | | | | | |
Collapse
|
27
|
Shimada K, Mitamura K, Higashi T. Gas chromatography and high-performance liquid chromatography of natural steroids. J Chromatogr A 2001; 935:141-72. [PMID: 11762773 DOI: 10.1016/s0021-9673(01)00943-8] [Citation(s) in RCA: 124] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
This review article underlines the importance of gas chromatography (GC), high-performance liquid chromatography (HPLC) and their hyphenated techniques using mass spectrometry (MS) for the determination of natural steroids, especially in human biological fluids. Steroids are divided into eight categories based on their structures and functions, and recent references using the above methodologies for the analysis of these steroids are cited. GC and GC-MS are commonly used for the determination of volatile steroids. Although HPLC is a widely used analytical method for the determination of steroids including the conjugated type in biological fluids, LC-MS is considered to be the most promising one for this purpose because of its sensitivity, specificity and versatility.
Collapse
Affiliation(s)
- K Shimada
- Faculty of Pharmaceutical Sciences, Kanazawa University, Japan.
| | | | | |
Collapse
|
28
|
Gonzalo-Lumbreras R, Izquierdo-Hornillos R. High-performance liquid chromatographic optimization study for the separation of natural and synthetic anabolic steroids. Application to urine and pharmaceutical samples. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2000; 742:1-11. [PMID: 10892579 DOI: 10.1016/s0378-4347(00)00026-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
An HPLC separation of a complex mixture containing 14 androgenic anabolic steroids (natural and synthetic) for screening purposes has been carried out. The applied optimization method involved the use of binary, ternary and quaternary mobile phases containing acetonitrile, methanol or tetrahydrofuran as organic modifiers. The effect of different reversed-phase packings and temperature on the separation using acetonitrile as organic modifier was studied. The optimum separation was achieved by using a water-acetonitrile (55:45, v:v) mobile phase and a Hypersil ODS (250 mm x 4.6 mm) 5 microm column (30 degrees C) in about 38 min, allowing the separation of 14 out of 14 compounds tested (when danazol is excluded, 13 out of 14 were separated in 23 min). Calibration graphs were obtained using bolasterone, methyltestosterone and canrenone as internal standards. Detection limits were in the range 0.012-0.11 microg ml(-1). The optimized separation was applied for monitoring the norethindrone acetate hydrolysis from tablets and to the analysis, after liquid-liquid extraction, of urine samples spiked with steroids.
Collapse
Affiliation(s)
- R Gonzalo-Lumbreras
- Departamento de Química Analítica, Facultad de Química, Universidad Complutense de Madrid, Spain
| | | |
Collapse
|