1
|
Hsu WL, Chen CW, Liang HH, Chiang TL, Lin HW, Lin YH. Innovative analysis of diazepam, zolpidem and their main metabolites in human urine by micelle-to-solvent stacking in capillary electrophoresis. J Pharm Biomed Anal 2024; 239:115898. [PMID: 38064769 DOI: 10.1016/j.jpba.2023.115898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 11/29/2023] [Accepted: 12/01/2023] [Indexed: 01/05/2024]
Abstract
Diazepam and zolpidem are the most widely used medications for managing insomnia. However, significant concerns regarding the potential risks of misuse and abuse problems arose in many literatures. While urine analysis is a valuable diagnostic tool, a challenge arises from the fact that some parent drugs may remain undetectable in urine. This necessitates concurrent monitoring of their metabolites. Here, we described an innovative on-line sample preconcentration technique known as micelle to solvent stacking (MSS) for the analysis of diazepam, zolpidem, and their main metabolites in urine. Several key parameters warrant further discussion to optimize the MSS model, enhancing its performance in terms of sensitivity and resolution. After optimizing the conditions, we conducted a validation test, achieving high correlation coefficients (greater than 0.9977) for intra-day and inter-day regression lines. Additionally, both the relative standard deviation (RSD) and relative error (RE) remained below 6.10% and 12.55%, respectively. The limits of detection (LODs, S/N = 3) for all five analytes ranged from 2.0 to 56 ng/mL. Compared to the conventional capillary zone electrophoresis method, this new approach exhibited remarkable sensitivity enhancements, ranging from 123 to 235-fold. Upon applying this method to actual urine samples from patients, we successfully detected nordiazepam, zolpidem, and its metabolites. This simple and sensitive approach has promising applications in supporting patient medication safety and bolstering forensic investigations.
Collapse
Affiliation(s)
- Wan-Ling Hsu
- School of Pharmacy, China Medical University, Taichung 406040, Taiwan, ROC
| | - Chia-Wen Chen
- School of Pharmacy, China Medical University, Taichung 406040, Taiwan, ROC
| | - Hsin-Hua Liang
- School of Pharmacy, China Medical University, Taichung 406040, Taiwan, ROC
| | - Tia-Ling Chiang
- School of Pharmacy, China Medical University, Taichung 406040, Taiwan, ROC
| | - Hsiang-Wen Lin
- School of Pharmacy, China Medical University, Taichung 406040, Taiwan, ROC; Department of Pharmacy, China Medical University Hospital, Taichung 404332, Taiwan, ROC
| | - Yi-Hui Lin
- School of Pharmacy, China Medical University, Taichung 406040, Taiwan, ROC.
| |
Collapse
|
2
|
Ultrasound-assisted electromembrane extraction of clonazepam from plasma and determination using capillary electrophoresis. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1181:122928. [PMID: 34536833 DOI: 10.1016/j.jchromb.2021.122928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 08/06/2021] [Accepted: 09/01/2021] [Indexed: 11/20/2022]
Abstract
In this work, ultrasound-assisted electromembrane extraction (UA-EME) coupled with capillary electrophoresis (CE) and diode array detection (DAD) was developed for the determination of clonazepam from plasma samples. A comparative study was carried out between conventional EME and UA-EME methods to investigate the influence of the ultrasound waves on the extraction efficiency. The central composite design was used for the optimization of the variables affecting these methods to achieve the best extraction efficiency. Under optimal extraction conditions, the UA-EME provided better extraction recovery in a shorter time (58% in 13 min) than the EME method (42% in 30 min). Ultrasound reduces the extraction time and increased recovery by reducing the thickness of the barrier layer. In addition, this method provided a higher pre-concentration factor (203) and a lower limit of detection (3 ng mL-1) with good repeatability (RSDs were less than 10.11%).
Collapse
|
3
|
Magnetic Micro-Solid-Phase Extraction Using a Novel Carbon-Based Composite Coupled with HPLC-MS/MS for Steroid Multiclass Determination in Human Plasma. Molecules 2021; 26:molecules26072061. [PMID: 33916782 PMCID: PMC8038327 DOI: 10.3390/molecules26072061] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 03/29/2021] [Accepted: 03/31/2021] [Indexed: 11/17/2022] Open
Abstract
A micron-sized sorbent, Magn-Humic, has been prepared by humic acids pyrolysis onto silica-coated magnetite. The material was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), thermogravimetric analysis (TGA), and Brunauer, Emmett, and Teller (BET) surface area measurements and applied for simultaneous magnetic solid-phase extraction (MSPE) of glucocorticoids, estrogens, progestogens, and androgens at ng mL−1 levels from human plasma followed by high-performance liquid chromatography coupled with mass spectrometry (HPLC–MS/MS). Due to the low affinity for proteins, steroids extraction was done with no need for proteins precipitation/centrifugation. As highlighted by a design of experiments, MSPE was performed on 250 µL plasma (after 1:4 dilution) by 50 mg Magn-Humic (reusable for eight extractions) achieving quantitative recovery and satisfying clean-up. This was improved by washing (2 mL 2% v/v formic acid) prior to analytes elution by 0.5 mL 1:1 v/v methanol-acetonitrile followed by 0.5 mL methanol; eluate reduction to 0.25 mL compensated the initial sample dilution. The accuracy was assessed in certified blank fetal bovine serum and in human plasma, gaining satisfactory recovery in the range 65–122%, detection limits in the range 0.02–0.3 ng mL−1 (0.8 ng mL−1 for 17-β-estradiol) and suitable inter-day precision (relative standard deviation (RSD) <14%, n = 3). The method was evaluated in terms of selectivity, sensitivity, matrix-effect, instrumental carry-over, and it was applied to human plasma samples.
Collapse
|
4
|
Speltini A, Merlo F, Maraschi F, Villani L, Profumo A. HA-C@silica sorbent for simultaneous extraction and clean-up of steroids in human plasma followed by HPLC-MS/MS multiclass determination. Talanta 2020; 221:121496. [PMID: 33076100 DOI: 10.1016/j.talanta.2020.121496] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/28/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023]
Abstract
Aim and novelty of this work are the development of a simple and straightforward analytical procedure for multiclass determination of steroid hormones in human plasma. The method entails a single pre-treatment step based on solid-phase extraction using a recently proposed sorbent phase (HA-C@silica). This is easily prepared with good reproducibility via pyrolysis of humic acids onto silica, and not yet tested in biological fluids. It proved to be advantageous as it showed poor affinity for the protein matrix constituents while quantitatively extracting and pre-concentrating the target analytes. Indeed, as demonstrated in bovine serum albumin solution, up to ca. 90% protein is not retained by the sorbent, similarly to the behaviour of restricted access carbon nanotubes, tested for comparison. The high albumin exclusion allowed a satisfactory clean-up avoiding protein precipitation and centrifugation before extraction. The extraction procedure, optimized by a chemometric approach (23 experimental design) in BSA solution, provided quantitative recovery (76-119%, n = 3) for all steroids working with 1:8-diluted plasma (2 mL) and 100 mg HA-C@silica. Before analytes elution by 1 mL methanol-acetonitrile (1:1, v/v), selective washings (2% v/v formic acid and 30% v/v methanol) were applied to remove the small fraction of retained proteins, thus obtaining very clean SPE extracts to be analyzed by HPLC-ESI-MS/MS. This allowed identification/quantification (MRM mode) at few ng mL-1 by a single chromatographic run. The procedure was verified in blank-certified foetal bovine serum (spikes 10-100 ng mL-1), obtaining good recovery and suitable inter-day precision (RSDs < 15%, n = 3). The analytical method, applied to real plasma samples analysis, is appealing in terms of sample throughput, extraction efficiency and clean-up.
Collapse
Affiliation(s)
- Andrea Speltini
- Department of Drug Sciences, University of Pavia, Via Taramelli 12, 27100, Pavia, Italy.
| | - Francesca Merlo
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100, Pavia, Italy
| | - Federica Maraschi
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100, Pavia, Italy
| | - Luana Villani
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100, Pavia, Italy
| | - Antonella Profumo
- Department of Chemistry, University of Pavia, Via Taramelli 12, 27100, Pavia, Italy.
| |
Collapse
|
5
|
Hassib ST, Hashem HMA, Mahrouse MA, Mostafa EA. Determination of four antiepileptic drugs in plasma using ultra-performance liquid chromatography with mass detection technique. Biomed Chromatogr 2018; 32:e4253. [PMID: 29637570 DOI: 10.1002/bmc.4253] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2017] [Revised: 03/13/2018] [Accepted: 03/26/2018] [Indexed: 11/07/2022]
Abstract
Status epilepticus (SE) is considered the second most frequent neurological emergency. Its therapeutic management is performed using sequential antiepileptic drug regimens. Diazepam (DIA), midazolam (MID), phenytoin (PHT) and phenobarbital (PB) are four drugs of different classes used sequentially in the management of SE. A sensitive, selective, accurate and precise method was developed and validated for simultaneous determination of the four antiepileptic drugs in human plasma. Their separation and quantification were achieved using ultra-performance liquid chromatography (UPLC) with mass detection using carbamazepine as internal standard (IS). For the first three drugs and the IS, UPLC-MS/MS with electrospray ionization working in multiple reaction monitoring mode was used at the following transitions: m/z 285 → 193 for DIA; m/z 326 → 291 for MID; m/z 253 → 182 for PHT; and m/z 237 → 194, 237 → 192 for IS. For the fourth drug (PB), a molecular ion peak of PB [M + H] + at m/z 233 was used for its quantitation. The method was linear over concentration ranges 5-500 ng/mL for DIA and MID and 0.25-20 μg/mL for PHT and PB. Bioanalytical validation of the developed method was carried out according to European Medicines Agency guidelines. The developed method can be applied for routine drug analysis, therapeutic drug monitoring and bioequivalence studies.
Collapse
Affiliation(s)
- Sonia T Hassib
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
| | - Hanaa M A Hashem
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
| | - Marianne A Mahrouse
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
| | - Eman A Mostafa
- Pharmaceutical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, Egypt
| |
Collapse
|
6
|
Pinto MAL, de Souza ID, Queiroz MEC. Determination of drugs in plasma samples by disposable pipette extraction with C18-BSA phase and liquid chromatography–tandem mass spectrometry. J Pharm Biomed Anal 2017; 139:116-124. [DOI: 10.1016/j.jpba.2017.02.052] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 02/24/2017] [Accepted: 02/28/2017] [Indexed: 11/16/2022]
|
7
|
The use of a temperature-responsive column for the direct analysis of drugs in serum by two-dimensional heart-cutting liquid chromatography. Anal Bioanal Chem 2016; 409:1059-1065. [PMID: 27796461 DOI: 10.1007/s00216-016-0024-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2016] [Revised: 10/08/2016] [Accepted: 10/10/2016] [Indexed: 10/20/2022]
Abstract
A novel pretreatment method, which was performed using a two-dimensional high-performance liquid chromatography (2D-HPLC) system, was proposed for the direct analysis of drugs in human serum. A temperature-responsive column was used as a pretreatment column. The stationary phase of the temperature-responsive column exhibits temperature-regulated hydrophilic/hydrophobic characteristics. Controlling the ionic strength of the eluent enables human serum albumin (HSA) to pass through the column without retention. When serum samples containing barbiturates or benzodiazepines were injected into the temperature-responsive column using 10 mM of ammonium acetate (pH 6.5) as the mobile phase and in the temperature range of 10-40 °C, HSA was eluted from the column near the dead time, followed by the individual drugs. When the column temperature was changed, the retention times of the drugs were altered owing to surface property changes within the pretreatment column. These closely eluted compounds were subsequently introduced into the analytical column using a column-switching valve, with a minimal gap time to avoid foreign substance contamination. This new 2D-HPLC method afforded high-quality chromatograms of multiple drugs without unwanted peaks from foreign substances. The present technique could be an attractive choice in selecting the analytical method for drug analysis.
Collapse
|
8
|
Voltammetry of benzodiazepines on meniscus-modified silver solid amalgam electrode. MONATSHEFTE FUR CHEMIE 2015. [DOI: 10.1007/s00706-015-1594-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
9
|
Abstract
AbstractBenzodiazepines (BDZs) are generally commonly used as anxiolytic and/or hypnotic drugs as a ligand of the GABAA-benzodiazepine receptor. Moreover, some of benzodiazepines are widely used as an anti-depressive and sedative drugs, and also as anti-epileptic drugs and in some cases can be useful as an adjunct treatment in refractory epilepsies or anti-alcoholic therapy. High-performance liquid chromatography (HPLC) methods, thin-layer chromatography (TLC) methods, gas chromatography (GC) methods, capillary electrophoresis (CE) methods and some of spectrophotometric and spectrofluorometric methods were developed and have been extensively applied to the analysis of number of benzodiazepine derivative drugs (BDZs) providing reliable and accurate results. The available chemical methods for the determination of BDZs in biological materials and pharmaceutical formulations are reviewed in this work.
Collapse
|
10
|
Chaichi MJ, Alijanpour SO. A new chemiluminescence method for determination of clonazepam and diazepam based on 1-Ethyl-3-Methylimidazolium Ethylsulfate/copper as catalyst. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2014; 118:36-41. [PMID: 24036305 DOI: 10.1016/j.saa.2013.08.087] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2013] [Revised: 08/20/2013] [Accepted: 08/22/2013] [Indexed: 06/02/2023]
Abstract
A novel chemiluminescence (CL) reaction, Benzodiazepines-H2O2-1-Ethyl-3-Methylimidazolium Ethylsulfate/copper, for determination of clonazepam and diazepam at nanogram per milliliter level in batch-type system have been described. The method relies on the catalytic effect of 1-Ethyl-3-Methylimidazolium Ethylsulfate/copper on the chemiluminescence reaction of Benzodiazepines, the oxidation of Benzodiazepines with hydrogen peroxide in natural medium. The influences of various experimental parameters such as solution pH, the ratio of 1-Ethyl-3 Methylimidazolium ethylsulfate concentration to copper ion, the type of buffer and the concentration of CL reagents were investigated. Under the optimum condition, the proposed method was satisfactorily applied for the determination of these drugs in tablets and urine without the interference of their potential impurities.
Collapse
Affiliation(s)
- M J Chaichi
- Faculty of Chemistry, Mazandaran University, Babolsar, Iran.
| | | |
Collapse
|
11
|
Wang R, Wang X, Liang C, Ni C, Xiong L, Rao Y, Zhang Y. Direct determination of diazepam and its glucuronide metabolites in human whole blood by μElution solid-phase extraction and liquid chromatography–tandem mass spectrometry. Forensic Sci Int 2013; 233:304-11. [DOI: 10.1016/j.forsciint.2013.10.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2013] [Revised: 09/25/2013] [Accepted: 10/05/2013] [Indexed: 10/26/2022]
|
12
|
Yuan Q, Liao Z, Wang F, Zhang H, Guo Y, Li R. A RAPID HILIC METHOD FOR ANALYSIS OF DIAZEPAM AND ESTAZOLAM IN HUMAN PLASMA. J LIQ CHROMATOGR R T 2013. [DOI: 10.1080/10826076.2012.678459] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Qin Yuan
- a Engineering Research Center of Eco-Environment in Three Gorges Reservoir Region, Ministry of Education , China Three Gorges University , Yichang , China
| | - Zhaojiang Liao
- a Engineering Research Center of Eco-Environment in Three Gorges Reservoir Region, Ministry of Education , China Three Gorges University , Yichang , China
| | - Fengling Wang
- b Hospital of China Three Gorges University , Yichang , China
| | - Huilian Zhang
- c Research Institute of Criminal Science and Technology , Yichang Municipal Public Security Bureau , Yichang , China
| | - Yali Guo
- a Engineering Research Center of Eco-Environment in Three Gorges Reservoir Region, Ministry of Education , China Three Gorges University , Yichang , China
| | - Ruiping Li
- a Engineering Research Center of Eco-Environment in Three Gorges Reservoir Region, Ministry of Education , China Three Gorges University , Yichang , China
| |
Collapse
|
13
|
Aqababa H, Tabandeh M, Tabatabaei M, Hasheminejad M, Emadi M. Computer-assisted design and synthesis of a highly selective smart adsorbent for extraction of clonazepam from human serum. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:189-95. [DOI: 10.1016/j.msec.2012.08.029] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2011] [Revised: 07/25/2012] [Accepted: 08/11/2012] [Indexed: 11/26/2022]
|
14
|
Extending the detection window of diazepam by directly analyzing its glucuronide metabolites in human urine using liquid chromatography–tandem mass spectrometry. J Chromatogr A 2012; 1268:29-34. [DOI: 10.1016/j.chroma.2012.10.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 10/08/2012] [Accepted: 10/09/2012] [Indexed: 11/19/2022]
|
15
|
Vardini MT, Mashayekhi HA, Saber-Tehrani M. DISPERSIVE LIQUID-LIQUID MICROEXTRACTION FOLLOWED BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY AS AN EFFICIENT AND SENSITIVE TECHNIQUE FOR THE SIMULTANEOUS DETERMINATION OF ALPRAZOLAM, OXAZEPAM, AND DIAZEPAM IN HUMAN URINE SAMPLES. J LIQ CHROMATOGR R T 2012. [DOI: 10.1080/10826076.2011.637277] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Affiliation(s)
| | - Hossein Ali Mashayekhi
- b Department of Chemistry , Tonekabon Branch, Islamic Azad University , Tonekabon , Iran
| | - Mohammad Saber-Tehrani
- c Department of Chemistry , Science and Research Branch, Islamic Azad University , Tehran , Iran
| |
Collapse
|
16
|
Maślanka A, Krzek J, Żuromska B, Stolarczyk M. Identification and determination of compounds belonging to the group of OUN pharmaceutical agents by thin-layer chromatography with densitometric detection in biological material. ACTA CHROMATOGR 2011. [DOI: 10.1556/achrom.23.2011.2.5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
17
|
Benzodiazepines: sample preparation and HPLC methods for their determination in biological samples. Bioanalysis 2011; 1:755-84. [PMID: 21083137 DOI: 10.4155/bio.09.43] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Benzodiazepines (BDZs) belong to a group of substances known for their sedative, antidepressive, muscle relaxant, tranquilizer, hypnotic and anticonvulsant properties. Their determination in biological fluids is essential in clinical assays as well as in forensics and toxicological studies. Researchers focus on the development of rapid, accurate, precise and sensitive methods for the determination of BDZs and their metabolites. A large number of analytical methods using different techniques have been reported, but none can be considered as the method of choice. BDZs are usually present at trace levels (microgram or nanogram per milliliter) in a complex biological matrix and the potentially interfering compounds must be isolated by various extraction techniques before analysis. An extended and comprehensive review is presented herein, focusing on sample preparation (pretreatment and extraction) and HPLC conditions applied by different authors. These methods enable bioanalysts to achieve detection limits down to 1-2 ng/ml using UV/diode array detection, readily available in most laboratories, and better than 1 ng/ml using electron capture detection, which is lower than that obtained using a nitrogen phosphorus detector. MS interfaced with electrospray ionization offered a similar sensitivity, while negative chemical ionization MS or sonic spray ionization MS provided sensitivity down to 0.1 ng/ml.
Collapse
|
18
|
Tabrizi AB, Harasi M. Applying cloud point extraction technique for the extraction of oxazepam from human urine as a colour or fluorescent derivative prior to spectroscopic analysis methods. Drug Test Anal 2011; 4:145-50. [PMID: 21381221 DOI: 10.1002/dta.259] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2010] [Revised: 12/18/2010] [Accepted: 12/18/2010] [Indexed: 11/07/2022]
Abstract
Two new methods based on cloud point extraction (CPE) technique were developed and optimized for the extraction and preconcentration of oxazepam from human urine, as an azo or fluorescent derivative. The first method is a spectrophotometric one, which is based on the acid hydrolysis of the oxazepam to a benzophenone, diazotization of the benzophenone, and then the coupling with oxine to form an azo dye. The second method is a spectrofluorimetric one, which involves reduction of the target compound using Zn°/HCl at room temperature with the formation of a highly fluorescent derivative. The main factors affecting the chemical reactions and CPE were investigated and optimized systematically. Under optimum experimental conditions, the calibration graphs were linear in the range of 0.1 to 1.5 (0.05 to 2.0) µg/ml with correlation coefficients of 0.9989 (0.9985), for the CPE-spectrophotometric (CPE-spectrofluorimetric) method. The limit of detection was found to be 0.034 (0.018) µg/ml and the relative standard deviation was calculated to be 1.35 (2.52)%. Recoveries in the spiked samples ranged from 87 to 94%. Finally, the proposed methods were applied to the determination of oxazepam in human urine.
Collapse
Affiliation(s)
- Ahad Bavili Tabrizi
- Department of Medicinal Chemistry, Faculty of Pharmacy & Biotechnology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | | |
Collapse
|
19
|
Chernetsova ES, Koryakova AG. High-performance liquid chromatography coupled to mass spectrometry for studying new pharmaceutical entities. JOURNAL OF ANALYTICAL CHEMISTRY 2010. [DOI: 10.1134/s1061934810140029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
20
|
Solid-phase microextraction in bioanalysis: New devices and directions. J Chromatogr A 2010; 1217:4041-60. [DOI: 10.1016/j.chroma.2009.11.061] [Citation(s) in RCA: 166] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2009] [Revised: 11/03/2009] [Accepted: 11/18/2009] [Indexed: 11/23/2022]
|
21
|
Design of packed-fiber solid-phase extraction device for analysis of the drug and its metabolite in plasma. Biomed Microdevices 2009; 11:723-9. [DOI: 10.1007/s10544-009-9285-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Umezawa H, Lee XP, Arima Y, Hasegawa C, Marumo A, Kumazawa T, Sato K. Determination of diazepam and its metabolites in human urine by liquid chromatography/tandem mass spectrometry using a hydrophilic polymer column. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:2333-2341. [PMID: 18618924 DOI: 10.1002/rcm.3613] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Diazepam and its major metabolites, nordazepam, temazepam and oxazepam, in human urine samples, were analyzed by liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using a hydrophilic polymer column (MSpak GF-310 4B), which enables direct injection of crude biological samples. Matrix compounds in urine were eluted first from the column, while the target compounds were retained on the polymer stationary phase. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All compounds showed base-peak ions due to [M+H]+ ions on LC/MS with positive ion electrospray ionization, and product ions were produced from each [M+H]+ ion by LC/MS/MS. Quantification was performed by selected reaction monitoring. All compounds spiked into urine showed method recoveries of 50.1-82.0%. The regression equations for all compounds showed excellent linearity in the range of 0.5-500 ng/mL of urine. The limits of detection and quantification for each compound were 0.1 and 0.5 ng/mL of urine, respectively. The intra- and inter-day coefficients of variation for all compounds in urine were not greater than 9.6%. The data obtained from actual determination of diazepam and its three metabolites, oxazepam, nordazepam and temazepam, in human urine after oral administration of diazepam, are also presented.
Collapse
Affiliation(s)
- Hironobu Umezawa
- Department of Legal Medicine, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo 142-8555, Japan
| | | | | | | | | | | | | |
Collapse
|
23
|
Mercolini L, Mandrioli R, Amore M, Raggi MA. Separation and HPLC analysis of 15 benzodiazepines in human plasma. J Sep Sci 2008; 31:2619-26. [DOI: 10.1002/jssc.200800212] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
24
|
Liquid chromatographic determination of enrofloxacin in nasal secretions and plasma of healthy pigs using restricted access material for on-line sample clean-up. J Chromatogr A 2008; 1189:456-66. [DOI: 10.1016/j.chroma.2007.11.011] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2007] [Revised: 10/24/2007] [Accepted: 11/01/2007] [Indexed: 11/18/2022]
|
25
|
Uddin MN, Samanidou VF, Papadoyannis IN. Development and Validation of an HPLC Method for the Determination of Six 1,4‐Benzodiazepines in Pharmaceuticals and Human Biological Fluids. J LIQ CHROMATOGR R T 2008. [DOI: 10.1080/10826070802019574] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Mohammad Nasir Uddin
- a Laboratory of Analytical Chemistry, Department of Chemistry , Aristotle University of Thessaloniki , Thessaloniki, Greece
| | - Victoria F. Samanidou
- a Laboratory of Analytical Chemistry, Department of Chemistry , Aristotle University of Thessaloniki , Thessaloniki, Greece
| | - Ioannis N. Papadoyannis
- a Laboratory of Analytical Chemistry, Department of Chemistry , Aristotle University of Thessaloniki , Thessaloniki, Greece
| |
Collapse
|
26
|
Dhavale N, Gandhi S, Sabnis S, Bothara K. Simultaneous HPTLC Determination of Escitalopram Oxalate and Clonazepam in Combined Tablets. Chromatographia 2008. [DOI: 10.1365/s10337-008-0524-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
27
|
Rogatsky E, Stein DT. Two-dimensional reverse phase-reverse phase chromatography: A simple and robust platform for sensitive quantitative analysis of peptides by LC/MS. Hardware design. J Sep Sci 2007; 29:538-46. [PMID: 16583692 DOI: 10.1002/jssc.200500474] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We have revised current two-dimensional RP-RP approaches and developed a new robust 2-D RP-RP platform. This platform was implemented on an Agilent 1100 2-D liquid chromatography system and is based on high pressure switching between two high-resolution RP columns. An independent binary gradient was implemented for each dimension. The powerful combination of dual analytical columns with independent gradient elution achieves high analyte purity, effectively eliminates matrix effects, and maximizes MS sensitivity in Q1 SIM comparable to the sensitivity enhancements of MS/MS-based methods. Implementation of dual simultaneous gradient profiles (overlapped gradients) reduces 2-D method run-time to the scale of 1-D method run-times. This robust and sensitive approach is particularly suitable for hydrophobic peptides and small proteins and can be used as a routine standard technique for enhanced on-line peptide purification coupled with mass spectrometric detection.
Collapse
Affiliation(s)
- Eduard Rogatsky
- Core Analytical Laboratory, General Clinical Research Center, Albert Einstein College of Medicine of Yeshiva University, Bronx, NY 10461, USA.
| | | |
Collapse
|
28
|
Samanidou VF, Pechlivanidou AP, Papadoyannis IN. Development of a validated HPLC method for the determination of four 1,4-benzodiazepines in human biological fluids. J Sep Sci 2007; 30:679-87. [PMID: 17461106 DOI: 10.1002/jssc.200600365] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A simple and sensitive HPLC method was developed and validated for the determination of four frequently prescribed 1,4-benzodiazepines: alprazolam (ALP), bromazepam (BRZ), diazepam (DZP), and flunitrazepam (FNZ). Separation was achieved on an Inertsil C8 analytical (250 mm x 4 mm, 5 microm) column, after selective extraction of benzodiazepine drugs from biological matrices by means of SPE. Isocratic elution was performed with a mobile phase consisting of CH3COONH4, 0.05 M CH3OH, and CH3CN (33:57:10 by volume). Quantification was performed at 240 nm with mefenamic acid (6 ng/microL) as the internal standard. DSC-18 Supelco cartridges provided high absolute recoveries (81-115%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <12%. Recoveries from biological samples ranged from 81.2 to 115%. The detection limit of the method was calculated as 3.3-10.2 ng in blood plasma and 2.6-12.6 ng in urine for 20 microL injection volume. The method was applied to spiked biological matrices. Moreover, the method was applied to real samples of urine after an oral administration.
Collapse
Affiliation(s)
- Victoria F Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | | | | |
Collapse
|
29
|
Liu M, Hashi Y, Pan F, Yao J, Song G, Lin JM. Automated on-line liquid chromatography–photodiode array–mass spectrometry method with dilution line for the determination of bisphenol A and 4-octylphenol in serum. J Chromatogr A 2006; 1133:142-8. [PMID: 16934275 DOI: 10.1016/j.chroma.2006.08.009] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2006] [Revised: 07/29/2006] [Accepted: 08/07/2006] [Indexed: 11/28/2022]
Abstract
A novel on-line liquid chromatography-photodiode array detection-mass spectrometry (LC-DAD-MS) system was established with restricted-access media (RAM) pre-column and dilution line combined with a column-switching valve. The serum samples were injected directly onto pre-column under diluted condition by dilution line. After elution of proteins in the serum, the analytes were backflushed onto an ODS analytical column using a six-port column-switching device. The influence of the composition of the mobile phase, for instance, organic modifer, ionic strength, pH, dilution times and the rotation time of the switching valve have been investigated using bisphenol A (BPA) and 4-octyphenol (4-OP) as analytes. The evaluations for peak responses and sensitivity were conducted by MS, and proteins were removed by RAM-column with DAD monitoring at 280 nm. The peak shape was improved by adding a dilution line, especially in the case of large volume injection (LVI), which increased the sensitivity of the analysis. The selective and sensitive quantification of BPA and 4-OP in serum sample could be finished within 25 min. The method had linearity in the range 0.1-500 ng/mL with a limit of quantification for BPA and 4-OP of 0.1 and 0.5 ng/mL, respectively. The recoveries were in the range of 80-101% with less than 9.0% RSDs. This on-line LC-MS method demonstrates potential application to evaluating the exposure and risk of BPA and 4-OP in human.
Collapse
Affiliation(s)
- Min Liu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085, China
| | | | | | | | | | | |
Collapse
|
30
|
Cheung A, Struble E, He J, Yang C, Wang E, Thurston DE, Liu P. Direct liquid chromatography determination of the reactive imine SJG-136 (NSC 694501). J Chromatogr B Analyt Technol Biomed Life Sci 2005; 822:10-20. [PMID: 15994138 DOI: 10.1016/j.jchromb.2005.04.027] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2004] [Revised: 02/19/2005] [Accepted: 04/28/2005] [Indexed: 11/23/2022]
Abstract
SJG-136 (NSC 694501), 8,8'-[[(propane-1,3-diyl)dioxy]bis[(11aS)-7-methoxy-2-methylidene-1,2,3,11a-tetrahydro-5H-pyrrolo[2,1-c][1,4]benzodiazepin-5-one], which is being developed as a DNA-interactive antitumor agent, contains highly reactive imines in the diazepinone portions of the molecule. Water or alcohol adds readily to the imino moiety to form the corresponding carbinolamine or its alkyl ether, respectively. This sensitivity to protic substances poses a formidable challenge to the formulation and HPLC assay development for the compound. After studying the solution chemistry of SJG-136 and its potential interaction with various stationary phases, two reversed-phase liquid chromatographic assays for the compound have been developed. A direct assay that separates SJG-136 from its water or methanol adducts and an indirect assay that quantifies SJG-136 as its dihydrate adduct are reported. The latter method, which is more practical for drug development, has been validated. It is reproducible (R.S.D.<2%), linear (r2=0.9999) and accurate (within 98-102% recovery), with a lower detection limit of 2.5 ng.
Collapse
Affiliation(s)
- Andrew Cheung
- SRI International, Analytical Chemistry Department, 333 Ravenswood Avenue, Menlo Park, CA 94025, USA
| | | | | | | | | | | | | |
Collapse
|
31
|
Wen Y, Fan Y, Zhang M, Feng YQ. Determination of camptothecin and 10-hydroxycamptothecin in human plasma using polymer monolithic in-tube solid phase microextraction combined with high-performance liquid chromatography. Anal Bioanal Chem 2005; 382:204-10. [PMID: 15900473 DOI: 10.1007/s00216-005-3194-4] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2005] [Revised: 02/19/2005] [Accepted: 02/22/2005] [Indexed: 10/25/2022]
Abstract
A biocompatible in-tube solid-phase microextraction (SPME) device was used for the direct and on-line extraction of camptothecin and 10-hydroxycamptothecin in human plasma. Biocompatibility was achieved through the use of a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column for extraction. Coupled to high performance liquid chromatography (HPLC) with UV detection, this on-line in-tube SPME method was successfully applied to the simultaneous determination of camptothecin and 10-hydroxycamptothecin in human plasma. The calculated detection limits for camptothecin and 10-hydroxycamptothecin were found to be 2.62 and 1.79 ng/mL, respectively. The method was linear over the range of 10-1000 ng/mL. Excellent method reproducibility was achieved, yielding RSDs of 2.49 and 1.59%, respectively. The detection limit (S/N = 3) of camptothecin was found to reach 0.1 ng/mL using fluorescence detection. The proposed method was shown to cope robustly with the extraction and analysis of camptothecin and 10-hydroxycamptothecin in plasma samples.
Collapse
Affiliation(s)
- Yi Wen
- Department of Chemistry, Wuhan University, Wuhan, 430072, People's Republic of China
| | | | | | | |
Collapse
|
32
|
Bares IF, Pehourcq F, Jarry C. Development of a rapid RP–HPLC method for the determination of clonazepam in human plasma. J Pharm Biomed Anal 2004; 36:865-9. [PMID: 15533681 DOI: 10.1016/j.jpba.2004.07.020] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2004] [Revised: 07/07/2004] [Accepted: 07/08/2004] [Indexed: 11/27/2022]
Abstract
A rapid and sensitive high-performance liquid chromatography method with UV detection was developed for the determination of clonazepam in human plasma using 3-methylclonazepam, as internal standard. A one-step extraction of both compounds was performed with a mixture of hexane/ethyl acetate (90:10, v/v). The HPLC analysis was carried out on a Nova Pak((R)) C(18) reversed-phase column with a mobile phase of acetonitrile-0.01 M sodium acetate adjusted to pH 7 with dilute acetic acid (40:60, v/v). A linear response was observed over the concentration range 5-100 ng/mL. Intra- and inter-day assay precision and accuracy fulfilled the international requirements. The lower limit of quantification was 5 ng/mL without interference of endogenous components. For analytical purpose, the stability of clonazepam in bidistilled water and plasma has been studied. A rapid degradation was noticed when clonazepam was stored in bidistilled water at the daylight following a first-order kinetic rate with a 87 min half life whereas no significant degradation was observed in plasma. This method was applied to measure plasma concentrations of clonazepam either in patients receiving therapeutic doses or in poisoning cases.
Collapse
Affiliation(s)
- Isabelle Forfar Bares
- EA 2962-Pharmacochimie, Université Victor Segalen Bordeaux 2, 146 rue Léo Saignat, 33076 Bordeaux Cedex, France.
| | | | | |
Collapse
|
33
|
Bugey A, Staub C. Rapid analysis of benzodiazepines in whole blood by high-performance liquid chromatography: use of a monolithic column. J Pharm Biomed Anal 2004; 35:555-62. [PMID: 15137980 DOI: 10.1016/j.jpba.2004.01.023] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2003] [Revised: 12/15/2003] [Accepted: 01/20/2004] [Indexed: 11/17/2022]
Abstract
In a previous work [J. Pharm. Biomed. Anal. 23 (2000) 447] a rapid high-performance liquid chromatography (HPLC) method, using a monolithic column in HPLC coupled with a diode-array detector, was developed for the quantitative determination of benzodiazepines in whole blood. The present method has been applied to the assay of eight benzodiazepines amongst the most frequently encountered in forensic toxicology: clonazepam, desalkylflurazepam, diazepam, flunitrazepam, lorazepam, midazolam, nordiazepam and oxazepam. The sample pre-treatment involved a liquid-liquid extraction of blood samples by n-butyl chloride. The separation was carried out in reversed-phase conditions using a Chromolith Performance (RP-18e 100 x 4.6 mm) column. The mobile phase was composed of a phosphate buffer (35 mM, pH 2.1) and acetonitrile (70:30, v/v) and the flow-rate was 2 ml/min. The duration of the analysis was less than 4 min and the results of validation, including linearity, precision, recovery, limit of quantification, were satisfactory. The therapeutic and toxic concentrations usually encountered for these substances could be measured. The compounds were separated by a monolithic column which, on account of its particular structure, could bear higher flow-rates than usually found for this kind of analysis. The present method has been applied to two real cases and was tested with about 30 compounds.
Collapse
Affiliation(s)
- Aurélie Bugey
- Institut Universitaire de Médecine Légale, 9, Avenue de Champel, 1211 Geneva 4, Switzerland
| | | |
Collapse
|
34
|
Souverain S, Rudaz S, Veuthey JL. Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 801:141-56. [PMID: 14751782 DOI: 10.1016/j.jchromb.2003.11.043] [Citation(s) in RCA: 213] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An analytical process generally involves four main steps: (1) sample preparation; (2) analytical separation; (3) detection; and (4) data handling. In the bioanalytical field, sample preparation is often considered as the time-limiting step. Indeed, the extraction techniques commonly used for biological matrices such as liquid-liquid extraction (LLE) and solid-phase extraction (SPE) are achieved in the off-line mode. In order to perform a high throughput analysis, efforts have been engaged in developing a faster sample purification process. Among different strategies, the introduction of special extraction sorbents, such as the restricted access media (RAM) and large particle supports (LPS), allowing the direct and repetitive injection of complex biological matrices, represents a very attractive approach. Integrated in a liquid chromatography (LC) system, these extraction supports lead to the automation, simplification and speeding up of the sample preparation process. In this paper, RAM and LPS are reviewed and particular attention is given to commercially available supports. Applications of these extraction supports, are presented in single column and column-switching configurations, for the direct analysis of compounds in various biological fluids.
Collapse
Affiliation(s)
- S Souverain
- Laboratory of Pharmaceutical Analytical Chemistry, School of Pharmacy, University of Geneva, 20 Bd. d'Yvoy, 12114 Geneva, Switzerland
| | | | | |
Collapse
|
35
|
Rbeida O, Christiaens B, Hubert P, Lubda D, Boos KS, Crommen J, Chiap P. Evaluation of a novel anion-exchange restricted-access sorbent for on-line sample clean-up prior to the determination of acidic compounds in plasma by liquid chromatography. J Chromatogr A 2004; 1030:95-102. [PMID: 15043258 DOI: 10.1016/j.chroma.2003.11.031] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A new kind of silica-based restricted-access material (RAM) with anionic properties has been tested in pre-columns for on-line solid-phase extraction of acidic compounds from directly injected plasma samples prior to their determination by reversed-phase liquid chromatography (LC), using the column-switching technique. The outer surface of the porous RAM particles contains hydrophilic diol groups while diethylaminoethyl (DEAE) groups are bound to the internal surface which gives the sorbent the properties of a weak anion exchanger towards low-molecular-mass compounds. Due to an appropriate pore diameter (about 6 nm), macromolecules, such as proteins, are physically excluded from the pores and flushed directly out during the sample clean-up process, while small compounds have access to the inner surface and can be retained mainly by electrostatic interactions. The retention capability of this novel packing material has been tested for some hydrophilic acidic compounds such as aspartic acid, glutamic acid, ascorbic acid and acetylcysteine as well as for some more hydrophobic drugs such as naproxen, ibuprofen and diclofenac, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The efficiency of the sorbent to clean-up complex matrices was also tested using human plasma and urine samples. A generic washing liquid composition was then selected in order to obtain efficient and selective sample clean-up as well as a high recovery of the acidic analytes.
Collapse
Affiliation(s)
- O Rbeida
- Department of Analytical Pharmaceutical Chemistry, Institute of Pharmacy, University of Liège, CHU, B36, B-4000 Liège 1, Belgium
| | | | | | | | | | | | | |
Collapse
|
36
|
Potentiometric determination of diazepam, bromazepam and clonazepam using solid contact ion-selective electrodes. Anal Chim Acta 2003. [DOI: 10.1016/j.aca.2003.08.070] [Citation(s) in RCA: 57] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
37
|
Polyethylene powder microcolumn for protein separation prior to HPLC plasma analysis. Application to the determination of copper and zinc. J Sep Sci 2003. [DOI: 10.1002/jssc.200301266] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
38
|
Mullett WM, Pawliszyn J. The development of selective and biocompatible coatings for solid phase microextraction. J Sep Sci 2003. [DOI: 10.1002/jssc.200390031] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
39
|
Chiap P, Rbeida O, Christiaens B, Hubert P, Lubda D, Boos KS, Crommen J. Use of a novel cation-exchange restricted-access material for automated sample clean-up prior to the determination of basic drugs in plasma by liquid chromatography. J Chromatogr A 2002; 975:145-55. [PMID: 12458755 DOI: 10.1016/s0021-9673(02)01334-1] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A new kind of silica-based restricted-access material (RAM) has been tested in pre-columns for the on-line solid-phase extraction (SPE) of basic drugs from directly injected plasma samples before their quantitative analysis by reversed-phase liquid chromatography (LC), using the column switching technique. The outer surface of the porous RAM particlescontains hydrophilic diol groups while sulphonic acid groups are bound to the internal surface, which gives the sorbent the properties of a strong cation exchanger towards low molecular mass compounds. Macromolecules such as proteins have no access to the internal surface of the pre-column due to their exclusion from the pores and are then flushed directly out. The retention capability of this novel packing material has been tested for some hydrophilic basic drugs, such as atropine, fenoterol, ipratropium, procaine, sotalol and terbutaline, used as model compounds. The influence of the composition of the washing liquid on the retention of the analytes in the pre-column has been investigated. The elution profiles of the different compounds and the plasma matrix as well as the time needed for the transfer of the analytes from the pre-column to the analytical column were determined in order to deduce the most suitable conditions for the clean-up step and develop on-line methods for the LC determination of these compounds in plasma. The cationic exchange sorbent was also compared to another RAM, namely RP-18 ADS (alkyl diol silica) sorbent with respect to retention capability towards basic analytes.
Collapse
Affiliation(s)
- P Chiap
- Department of Analytical Pharmaceutical Chemistry, Institute of Pharmacy, University of Liège, CHU-B36, B-400 Liège 1, Belgium
| | | | | | | | | | | | | |
Collapse
|
40
|
Mullett WM, Levsen K, Lubda D, Pawliszy J. Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum. J Chromatogr A 2002; 963:325-34. [PMID: 12187987 DOI: 10.1016/s0021-9673(02)00216-9] [Citation(s) in RCA: 90] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.
Collapse
Affiliation(s)
- Wayne M Mullett
- Chemistry Department, University of Waterloo, Ontario, Canada
| | | | | | | |
Collapse
|
41
|
Mullett WM, Pawliszyn J. Direct determination of benzodiazepines in biological fluids by restricted-access solid-phase microextraction. Anal Chem 2002; 74:1081-7. [PMID: 11924967 DOI: 10.1021/ac010747n] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A biocompatible solid-phase microextraction (SPME) fiber was prepared using an alkyl-diol-silica (ADS) restricted-access material as the SPME coating. The ADS-SPME fiber was able to simultaneously fractionate the protein component from a biological sample, while directly extracting several benzodiazepines, overcoming the present disadvantages of direct sampling in biological matrixes by SPME. The fiber was interfaced with an HPLC-UV system, and an isocratic mobile phase was used to desorb, separate, and quantify the extracted compounds. The calculated clonazepam, oxazepam, temazepam, nordazepam, and diazepam detection limits were 600, 750, 333, 100, and 46 ng/mL in urine, respectively. The method was confirmed to be linear over the range of 500-50000 ng/mL with an average linear coefficient (R2) value of 0.9918. The injection repeatability and intraassay precision of the method were evaluated over 10 injections, resulting in a RSD of approximately 6%. The ADS-SPME fiber was robust and simple to use, providing many direct extractions and subsequent determination of benzodiazepines in biological fluids.
Collapse
Affiliation(s)
- Wayne M Mullett
- Department of Chemistry, University of Waterloo, Ontario, Canada
| | | |
Collapse
|