1
|
Suchanek M, Paczosa-Bator B, Piech R. A Novel Composite Voltammetric Sensor Based on Yttria-Stabilized Zirconia Doped with Neodymium-Carbon Black-Nafion Glassy Carbon Electrode for Metoprolol Determination. MEMBRANES 2023; 13:890. [PMID: 38132894 PMCID: PMC10744395 DOI: 10.3390/membranes13120890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 11/06/2023] [Accepted: 11/23/2023] [Indexed: 12/23/2023]
Abstract
For the first time, a new composite voltammetric sensor based on yttria-stabilized zirconia doped with neodymium-carbon black-Nafion glassy carbon electrode (YSZNd-CB-Nafion/GCE) for the determination of metoprolol (MET) has been developed. The instrumental parameters and supporting electrolyte were optimized. For 105 s accumulation time, linearity was achieved in the range of 0.01 to 0.2 µM. The limit of detection (for 105 s accumulation time) was equal to 2.9 nM (2 µg/L), and was the best result in comparison to other voltametric sensors. The reproducibility of the metoprolol signal presented as relative standard deviation (RSD) was equal to 1.9% (n = 7). Additionally, our electrode is characterized by high stability, is easy to use, and has a short preparation time. The proposed sensor was found useful for MET determination in plasma and urine, as well as for pharmaceutical samples, with a good recovery parameter (96-108%). Flow injection analysis (FIA) with amperometric detection was also performed for MET determination. The recovery was calculated and was in the range 101-103%, suggesting that the proposed material may be applied in flow injection analysis.
Collapse
Affiliation(s)
- Małgorzata Suchanek
- Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Krakow, Al. A. Mickiewicza, 30-059 Krakow, Poland;
| | | | - Robert Piech
- Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Krakow, Al. A. Mickiewicza, 30-059 Krakow, Poland;
| |
Collapse
|
2
|
Horváth S, Gritti F, Horváth K. Theoretical study of the efficiency of liquid chromatography columns with particle size gradient. J Chromatogr A 2021; 1651:462331. [PMID: 34153736 DOI: 10.1016/j.chroma.2021.462331] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 06/04/2021] [Accepted: 06/06/2021] [Indexed: 11/17/2022]
Abstract
Modern analytical applications of liquid chromatography require more and more efficient columns. In this work, the possibility of utilizing particle size gradient in the chromatographic column was studied by a theoretical approach. In the course of our work three different scenarios of particle size gradients were considered with different shapes (linear, convex and concave). The evolution of bandwidth inside the column was plotted for each scenario. As a reference point, the bandwidth of the uniform column was used, which had the same pressure drop as the non-uniform column. According to our calculations, in isocratic elution mode, the non-uniform column does not offer any advantage compared to the uniform column, regardless the type of the particle size gradient. In gradient elution mode, however, extra band compression occurs was found. For negative particle size gradients, the final physical bandwidth was found to be approximately 1-4 % smaller than for uniform columns. This slight gain in efficiency in terms of bandwidth compression can be expanded to 5-8 % by the optimization of the limiting particle sizes. These optimized results are obtained when the final particle size is approximately 40% of the initial particle diameter.
Collapse
Affiliation(s)
- Szabolcs Horváth
- Research Group of Analytical Chemistry, University of Pannonia, Egyetem utca 10, Veszprém H-8200, Hungary
| | - Fabrice Gritti
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States
| | - Krisztián Horváth
- Research Group of Analytical Chemistry, University of Pannonia, Egyetem utca 10, Veszprém H-8200, Hungary
| |
Collapse
|
3
|
Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review. Anal Chim Acta 2016; 923:1-23. [DOI: 10.1016/j.aca.2016.03.040] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 03/17/2016] [Accepted: 03/21/2016] [Indexed: 01/22/2023]
|
4
|
Nezhadali A, Mojarrab M. Computational design and multivariate optimization of an electrochemical metoprolol sensor based on molecular imprinting in combination with carbon nanotubes. Anal Chim Acta 2016; 924:86-98. [DOI: 10.1016/j.aca.2016.04.017] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2016] [Revised: 04/09/2016] [Accepted: 04/14/2016] [Indexed: 12/11/2022]
|
5
|
Bae SH, Lee JK, Cho DY, Bae SK. Simultaneous determination of metoprolol and its metabolites, α-hydroxymetoprolol and O-desmethylmetoprolol, in human plasma by liquid chromatography with tandem mass spectrometry: Application to the pharmacokinetics of metoprolol associated with CYP2D6 genotypes. J Sep Sci 2014; 37:1256-64. [PMID: 24648255 DOI: 10.1002/jssc.201301353] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Revised: 03/09/2014] [Accepted: 03/09/2014] [Indexed: 11/07/2022]
Abstract
A rapid and simple LC with MS/MS method for the simultaneous determination of metoprolol and its two CYP2D6-derived metabolites, α-hydroxy- and O-desmethylmetoprolol, in human plasma was established. Metoprolol (MET), its two metabolites, and the internal standard chlorpropamide were extracted from plasma (50 μL) using ethyl acetate. Chromatographic separation was performed on a Luna CN column with an isocratic mobile phase consisting of distilled water and methanol containing 0.1% formic acid (60:40, v/v) at a flow rate of 0.3 mL/min. The total run time was 3.0 min per sample. Mass spectrometric detection was conducted by ESI in positive ion selected-reaction monitoring mode. The linear ranges of concentration for MET, α-hydroxymetoprolol, and O-desmethylmetoprolol were 2-1000, 2-500, and 2-500 ng/mL, respectively, with a lower limit of quantification of 2 ng/mL for all analytes. The coefficient of variation for the assay's precision was ≤ 13.2%, and the accuracy was 89.1-110%. All analytes were stable under various storage and handling conditions and no relevant cross-talk and matrix effect were observed. Finally, this method was successfully applied to assess the influence of CYP2D6 genotypes on the pharmacokinetics of MET after oral administration of 100 mg to healthy Korean volunteers.
Collapse
Affiliation(s)
- Soo Hyeon Bae
- College of Pharmacy, The Catholic University of Korea, Bucheon, Korea
| | | | | | | |
Collapse
|
6
|
Development of a sensitive and rapid method for quantitation of ( S)-(-)- and ( R)-(+)-metoprolol in human plasma by chiral LC-ESI-MS/MS. J Pharm Anal 2013; 4:63-79. [PMID: 29403869 PMCID: PMC5761053 DOI: 10.1016/j.jpha.2013.02.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2012] [Accepted: 02/18/2013] [Indexed: 12/02/2022] Open
Abstract
A selective, sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC–ESI–MS/MS) method has been developed for separation and quantification of metoprolol enantiomers on a chiral Lux Amylose-2 (250 mm×4.6 mm, 5 μm) column. Solid phase extraction of (S)-(−)- and (R)-(+)-metoprolol and rac-metoprolol-d6 as an internal standard (IS) was achieved on Lichrosep DVB HL cartridges employing 200 μL human plasma. Both the analytes were chromatographically separated with a resolution factor of 2.24 using 15 mM ammonium acetate in water, pH 5.0 and 0.1% (v/v) diethyl amine in acetonitrile (50:50, v/v) as the mobile phase within 7.0 min. The precursor→product ion transitions for the enantiomers and IS were monitored in the multiple reaction monitoring and positive ionization mode. The method was validated over the concentration range of 0.500–500 ng/mL for both the enantiomers. Matrix effect was assessed by post-column analyte infusion experiment and the mean extraction recovery was greater than 94.0% for both the enantiomers at all quality control levels. The stability of analytes was evaluated in plasma and whole blood under different storage conditions. The method was successfully applied to a clinical study in 14 healthy volunteers after oral administration of 200 mg metoprolol tablet under fasting conditions. The assay reproducibility is shown by reanalysis of 68 incurred samples. The suitability of the developed method was assessed in comparison with different chromatographic methods developed for stereoselective analysis of metoprolol in biological matrices.
Collapse
|
7
|
Human DBS sampling with LC–MS/MS for enantioselective determination of metoprolol and its metabolite O-desmethyl metoprolol. Bioanalysis 2010; 2:1437-48. [DOI: 10.4155/bio.10.107] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
>Background: The dried blood spots (DBS) sampling technique has been gaining wide interest in preclinical and clinical studies due to its inherent advantages. However, the impact of DBS sampling on chiral compounds in terms of stability and detection sensitivity has not been studied yet. Results: A high-throughput, sensitive and enantioselective LC–MS/MS-based bioanalytical method was developed and validated for the simultaneous determination of individual enantiomers of metoprolol and its metabolite O-desmethylmetoprolol (O-DMM)in human whole blood using the DBS sampling technique. Conclusions: The developed DBS LC–MS/MS assay has a run time of 3 min, shorter than all previous methods while achieving complete baseline separation of enantiomeric metoprolol and O-DMM. This study demonstrates the applicability of DBS for chiral molecules analysis.
Collapse
|
8
|
Solid-Phase Extraction of Metoprolol onto (Methacrylic acid- ethylene glycol dimethacrylate)-based Molecularly Imprinted Polymer and Its Spectrophotometric Determination. CHINESE J CHEM 2010. [DOI: 10.1002/cjoc.201090127] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
9
|
BARANOWSKA I, MARKOWSKI P, BARANOWSKI J. Development and Validation of an HPLC Method for the Simultaneous Analysis of 23 Selected Drugs Belonging to Different Therapeutic Groups in Human Urine Samples. ANAL SCI 2009; 25:1307-13. [DOI: 10.2116/analsci.25.1307] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Irena BARANOWSKA
- Department of Analytical and General Chemistry, Faculty of Chemistry, Silesian University of Technology
| | - Piotr MARKOWSKI
- Department of Analytical and General Chemistry, Faculty of Chemistry, Silesian University of Technology
| | | |
Collapse
|
10
|
Jensen BP, Sharp CF, Gardiner SJ, Begg EJ. Development and validation of a stereoselective liquid chromatography–tandem mass spectrometry assay for quantification of S- and R-metoprolol in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 865:48-54. [DOI: 10.1016/j.jchromb.2008.02.006] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2007] [Revised: 02/07/2008] [Accepted: 02/14/2008] [Indexed: 11/24/2022]
|
11
|
Wang Z, Ouyang J, Baeyens WR. Recent developments of enantioseparation techniques for adrenergic drugs using liquid chromatography and capillary electrophoresis: A review. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 862:1-14. [DOI: 10.1016/j.jchromb.2007.11.034] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2007] [Revised: 10/20/2007] [Accepted: 11/23/2007] [Indexed: 10/22/2022]
|
12
|
Felix G, Berthod A. Commercial Chiral Stationary Phases for the Separations of Clinical Racemic Drugs. SEPARATION AND PURIFICATION REVIEWS 2007. [DOI: 10.1080/15422110701826997] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
13
|
Oh JW, Trung TQ, Sin KS, Kang JS, Kim KH. Determination of bevantolol enantiomers in human plasma by coupled achiral–chiral high performance-liquid chromatography. Chirality 2007; 19:528-35. [PMID: 17457831 DOI: 10.1002/chir.20410] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A coupled achiral-chiral high performance liquid chromatographic method was developed and fully validated for the determination of bevantolol enantiomers, (-)-(S)-bevantolol and (+)-(R)-bevantolol, in human plasma. Plasma samples were prepared by solid phase extraction with Sep-Pak Plus C18 cartridges followed by HPLC. Bevantolol enantiomers and (+)-(R)-Propranolol as internal standard (IS) were preseparated from interfering components in plasma on a Phenomenex silica column and bevantolol enantiomers and IS were resolved and determined on a Chiralcel OJ-H chiral stationary phase. The two columns were connected by a switching valve equipped with silica precolumn. The Precolumn was used to concentrate bevantolol in the eluent from the achiral column before back flushing onto chiral phase. A detailed validation of the method was performed accordingly to FDA guidelines. For each enantiomer the assay was linear between 20 and 1600 ng/ml. The quantification limits of both bevantolol enantiomers were 20 ng/ml. The intraday variation was between 1.07 and 12.64% in relation to the measured concentration and the interday variation was 0.91 and 11.79%. The method has been applied to the determination of (-)-(S)- and (+)-(R)-bevantolol in plasma from healthy volunteers dosed with racemic bevantolol hydrochloride.
Collapse
Affiliation(s)
- Joung Weon Oh
- College of Pharmacy, Kangwon National University, Chuncheon, Republic of Korea
| | | | | | | | | |
Collapse
|
14
|
Boralli VB, Coelho EB, Cerqueira PM, Lanchote VL. Stereoselective analysis of metoprolol and its metabolites in rat plasma with application to oxidative metabolism. J Chromatogr B Analyt Technol Biomed Life Sci 2005; 823:195-202. [PMID: 16029965 DOI: 10.1016/j.jchromb.2005.06.038] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2005] [Revised: 06/22/2005] [Accepted: 06/24/2005] [Indexed: 10/25/2022]
Abstract
We investigated the stereoselective kinetic disposition and metabolism of metoprolol (MET) in rats. The racemic MET (15 mg/kg) was given by oral gavage and blood samples were collected from 0 to 10h (n=6 at each time point). The enantiomeric concentrations of MET and its metabolites alpha-hydroxymetoprolol (alpha-OHM) and O-demethylmetoprolol (ODM) were determined by HPLC using a Chiralpak AD chiral column and fluorescence detection. The pharmacokinetic parameters of unchanged MET and the formation of ODM did not show to be stereoselective. In contrast, the AUC (ng h/mL) of alpha-hydroxymetoprolol isomers were higher to I'R [638.2(525.2-706.2) for 1'R2R and 659.6(580.4-698.1) for 1'R,2S, mean, (95%CI)] than to I'S products [58.3(47.4-66.1) for 1'S,2R and 57.1(44.7-67.9) for 1'S,2S, mean, (95%CI)]. We conclude that the kinetic disposition of unchanged MET and the formation of ODM are not enantioselective in rats but the metabolism of alpha-OHM yields predominantly the 1'R-product.
Collapse
Affiliation(s)
- Vanessa Bergamin Boralli
- Departamento de Análises Clínicas, Toxicológicas e Bromatológicas, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, Avenida do Café s/n, Campus da USP, 14040-903 Ribeirão Preto, SP, Brazil
| | | | | | | |
Collapse
|
15
|
Rahman N, Rahman H, Azmi SNH. Validated Kinetic Spectrophotometric Method for the Determination of Metoprolol Tartrate in Pharmaceutical Formulations. Chem Pharm Bull (Tokyo) 2005; 53:942-8. [PMID: 16079525 DOI: 10.1248/cpb.53.942] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A kinetic spectrophotometric method has been described for the determination of metoprolol tartrate in pharmaceutical formulations. The method is based on reaction of the drug with alkaline potassium permanganate at 25+/-1 degrees C. The reaction is followed spectrophotometrically by measuring the change in absorbance at 610 nm as a function of time. The initial rate and fixed time (at 15.0 min) methods are utilized for constructing the calibration graphs to determine the concentration of the drug. Both the calibration graphs are linear in the concentration range of 1.46 x 10(-6)-8.76 x 10(-6) M (10.0-60.0 microg per 10 ml). The calibration data resulted in the linear regression equations of log (rate)=3.634+0.999 log C and A=6.300 x 10(-4)+6.491 x 10(-2) C for initial-rate and fixed time methods, respectively. The limits of quantitation for initial rate and fixed time methods are 0.04 and 0.10 microg ml(-1), respectively. The activation parameters such as E(a), DeltaH(double dagger), DeltaS(double dagger) and DeltaG(double dagger) are also evaluated for the reaction and found to be 90.73 kJ mol(-1), 88.20 kJ mol(-1), 84.54 J K(-1) mol(-1) and 63.01 kJ mol(-1), respectively. The results are validated statistically and through recovery studies. The method has been successfully applied to the determination of metoprolol tartrate in pharmaceutical formulations. Statistical comparison of the results with the reference method shows excellent agreement and indicates no significant difference in accuracy and precision.
Collapse
Affiliation(s)
- Nafisur Rahman
- Department of Chemistry, Aligarh Muslim University, Aligarh-202002 U.P., India.
| | | | | |
Collapse
|
16
|
Misl'anová C, Hutta M. Role of biological matrices during the analysis of chiral drugs by liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2003; 797:91-109. [PMID: 14630145 DOI: 10.1016/j.jchromb.2003.07.018] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The review article covers advances of chiral drugs analysis by high-performance liquid chromatography (HPLC) methods achieved during last 10 years. Emphasis is given to various aspects of influence of biological matrix in pharmacodynamics, pharmacokinetics, HPLC analysis. Discussed is composition of main biological matrices from the point of view of potential interferences to above-mentioned fields of study. Beside typical analytical approaches to chiral recognition in HPLC, sample pretreatment and/or clean-up by conventional extraction procedures, column switching (CSW) techniques using restricted access materials (RAMs), microdialysis (MCD) is discussed. Measurement of unbound drug concentration and discussion of column maintenance and remedy is an additional source of information and field where knowledge on complex properties and interactions of biological matrix is usefully applicable.
Collapse
Affiliation(s)
- Csilla Misl'anová
- Institute of Preventive and Clinical Medicine, Limbová 14, SK-833 01 37 Bratislava, Slovak Republic.
| | | |
Collapse
|
17
|
Cerqueira PM, Cesarino EJ, Bertucci C, Bonato PS, Lanchote VL. Stereoselective metabolism of metoprolol: enantioselectivity of alpha-hydroxymetoprolol in plasma and urine. Chirality 2003; 15:542-9. [PMID: 12774293 DOI: 10.1002/chir.10244] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Direct stereoselective separation on chiral stationary phase was developed for HPLC analysis of the four stereoisomers of alpha-hydroxymetoprolol in human plasma and urine. Plasma samples were prepared using solid-phase extraction columns and urine samples were prepared by liquid-liquid extraction. The stereoisomers were separated on a Chiralpak AD column at 24 degrees C with fluorescence detection and a mobile phase consisting of a mixture of hexane:ethanol:isopropanol:diethylamine (88:10.2:1.8:0.2) for plasma samples and hexane:ethanol:diethylamine (88:12:0.2) for urine samples. Calibration curves for the individual stereoisomers were linear within the concentration range of 2.0-200 ng/ml plasma or 0.125-25 microg/ml urine. The methods were validated with intra- and interday variations less than 15%. The absolute configuration of the pure stereoisomers were assigned by circular dichroism spectra. The methods were employed to determine the concentrations of alpha-hydroxymetoprolol stereoisomers in a metabolism study of multiple-dose administration of racemic metoprolol to hypertensive patients phenotyped as extensive metabolizers of debrisoquine. We observed stereo-selectivity in the alpha-hydroxymetoprolol formation favoring the new 1'R chiral center from both metoprolol enantiomers (AUC(0-24) (1'R1'S) = 3.02). The similar renal clearances (Cl(R)) of the four stereoisomers demonstrated absence of stereoselectivity in their renal excretion. (-)-(S)-metoprolol was slightly more alpha-hydroxylated than its antipode (AUC(0-24) (2S/2R) = 1.19), suggesting that this pathway is not responsible for plasma accumulation of this enantiomer in humans.
Collapse
|
18
|
Zhang X, Ouyang J, Baeyens WRG, Zhai S, Yang Y, Huang G. Enantiomeric separation of beta-blockers by HPLC using (R)-1-naphthylglycine and 3,5-dinitrobenzoic acid as chiral stationary phase. J Pharm Biomed Anal 2003; 31:1047-57. [PMID: 12667921 DOI: 10.1016/s0731-7085(02)00697-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Direct liquid chromatographic separations of the enantiomers of metoprolol and bisoprolol have been developed, using (R)-1-naphthylglycine and 3,5-dinitrobenzoic acid as chiral stationary phase (CSP). The separations were achieved in a normal phase system employing a mobile phase containing n-hexane, 1,2-dichloroethane and methanol. Column efficiency was strongly dependent on the composition of the mobile phase. The eluent contents of methanol and of 1,2-dichloroethane were optimized, and so was flow-rate and column temperature. Under the optimal conditions, linear responses for (R)-metoprolol and (S)-metoprolol are obtained in the range of 0.079-1.38 and 0.015-5.80 mg/ml, with detection limits of 0.008 and 0.002 mg/ml, respectively. As for bisoprolol, the linear ranges of (R)-isomer and (S)-isomer are 0.05-1.31 and 0.02-1.00 mg/ml with detection limits of 0.001 and 0.008 mg/ml, respectively. The relative standard deviation (R.S.D.) of each enantiomer did not exceed 0.90%. The method has been successfully applied to the determination of enantiomers in pharmaceuticals.
Collapse
Affiliation(s)
- Xianhua Zhang
- Department of Chemistry, Beijing Normal University, Beijing 100875, People's Republic of China
| | | | | | | | | | | |
Collapse
|
19
|
Bojarski J. Stereoselective chromatography of cardiovascular drugs: an update. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS 2002; 54:197-220. [PMID: 12543499 DOI: 10.1016/s0165-022x(02)00143-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
This review reports the latest achievements in chromatographic enantioseparations of various classes of cardiovascular drugs and selected applications of these methods in pharmaceutical and clinical analysis. The use of these drugs as test compounds for new chiral stationary phases and different parameters of chromatographic processes is also presented.
Collapse
Affiliation(s)
- Jacek Bojarski
- Department of Organic Chemistry, Medical College, Faculty of Pharmacy, Jagiellonian University, Medyczna 9, 30-688 Cracow, Poland.
| |
Collapse
|
20
|
Sweeney AP, Shalliker RA. Development of a two-dimensional liquid chromatography system with trapping and sample enrichment capabilities. J Chromatogr A 2002; 968:41-52. [PMID: 12236513 DOI: 10.1016/s0021-9673(02)00782-3] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A two-dimensional HPLC system was developed where "heart-cutting" chromatography, in conjunction with cold temperature trapping, was used to isolate and concentrate specific sample analytes. Low molecular mass polystyrene oligomers were used as model compounds to illustrate the operation of the instrument and evaluate the performance of the trapping system. A critical factor in the operation of the trapping system was the relative degree of retention between the first column and the trapping column. The results of this study showed that up to 32 consecutive heart-cut fractions from the first separation dimension could be stored in a trapping column with good analyte recovery and without significant loss in resolution upon elution on the second separation dimension.
Collapse
Affiliation(s)
- Alan P Sweeney
- Centre for Biostructural and Biomolecular Research, University of Western Sydney, Richmond, NSW, Australia
| | | |
Collapse
|
21
|
Kim KH, Lee JH, Ko MY, Shin KS, Kang JS, Mar WC, Youm JR. Determination of metoprolol enantiomers in human urine by GC-MS using (−)-α-methoxy-α-(trifluoromethyl)phenylacetyl chloride as a chiral derivatizing agent. Chromatographia 2002. [DOI: 10.1007/bf02492319] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
22
|
Mistry B, Leslie JL, Eddington ND. Enantiomeric separation of metoprolol and alpha-hydroxymetoprolol by liquid chromatography and fluorescence detection using a chiral stationary phase. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 758:153-61. [PMID: 11486824 DOI: 10.1016/s0378-4347(01)00166-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A sensitive and stereoselective high-performance liquid chromatographic assay for the determination of the enantiomers of metoprolol (R- and S-) and the diastereoisomers of alpha-hydroxymetoprolol (IIA, IIB) in plasma is reported. Chromatography involved direct separation of enantiomers using a Chirobiotic T bonded phase column (250 x 4.6 mm) and a mobile phase consisting of acetonitrile-methanol-methylene chloride-glacial acetic acid-triethylamine (56:30:14:2:2, v/v). Solid-phase extraction using silica bonded with ethyl group (C2) was used to extract the compounds of interest from plasma and atenolol was used as the internal standard. The column effluent was monitored using fluorescence detection with excitation and emission wavelengths of 225 and 310 nm, respectively. S-Metoprolol, R-metoprolol, IIB and IIA eluted at about 5.9, 6.7, 7.3 and 8.2 min without any interfering peaks. The calibration curve was linear over the range of 0.5 to 100 ng/ml for each isomer of metoprolol and 1 to 100 ng/ml for each isomer of alpha-hydroxymetoprolol (IIA & IIB). The mean intra-run accuracies were in the range of 96.2 to 114% for R-metoprolol, 94.0 to 111% for S-metoprolol, 90.2 to 110% for IIA, and 94.6 to 106% for IIB. The mean intra-run precisions were all in the range of 2.2 to 12.0% for R-metoprolol, 2.1 to 11.1% for S-metoprolol, 1.9 to 14.5% for IIA, and 3.2 to 11.0% for IIB. The lowest level of quantitation for the enantiomers of metoprolol was 0.5 ng/ml and 1.0 ng/ml for alpha-hydroxymetoprolol (IIA and IIB). The absolute recoveries for each analyte was > or = 95%. The validated method accurately quantitated the enantiomers of parent drug and metabolite after a single dose of an extended release metoprolol formulation.
Collapse
Affiliation(s)
- B Mistry
- Department of Pharmaceutical Sciences, School of Pharmacy, University of Maryland, Baltimore 21201-6808, USA
| | | | | |
Collapse
|
23
|
Lim HK, Linh PT, Hong CH, Kim KH, Kang JS. Enantioselective determination of metoprolol and major metabolites in human urine by capillary electrophoresis. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 755:259-64. [PMID: 11393712 DOI: 10.1016/s0378-4347(01)00118-9] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The enantiomeric separation of metoprolol and its metabolites in human urine was undertaken using capillary electrophoresis (CE). Resolution of the enantiomers was achieved using carboxymethyl-beta-cyclodextrin (CM-beta-CD) as the chiral selector. A 100-mM acetate buffer (pH 4.0) containing 5% 2-propanol and 10 mM CM-beta-CD resulted in the optimum separation of the metoprolol enantiomers and its acidic metabolite in human urine. Following a single metoprolol oral administration of 100 mg racemic metoprolol tartrate, stereoselective pharmacokinetic analysis showed that urinary acidic metabolite 3 of metoprolol accounted for 62.3% of the dose with an R/S ratio of 1.23 and urinary unchanged metoprolol 1 accounted for 6.3% of the dose with an R/S ratio of 0.72.
Collapse
Affiliation(s)
- H K Lim
- College of Pharmacy, Chungnam National University, Taejon, South Korea
| | | | | | | | | |
Collapse
|