1
|
Leite TFDO, da Silva ER, Evelyn K, Tirapelli DPDC, Joviliano EE. Expression of Plasma Levels of miRNA-181b and miRNA-21 in Patients With Abdominal Aortic Aneurysms and Their Effect on Clinical Outcome After Endovascular Treatment. J Endovasc Ther 2025:15266028251314352. [PMID: 39878154 DOI: 10.1177/15266028251314352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2025]
Abstract
INTRODUCTION Abdominal aortic aneurysms (AAA) are major causes of morbidity and mortality in the elderly population. Endovascular aneurysm repair (EVAR) is associated with lower complications rates than conventional treatment; however, rigorous follow-up with contrast imaging is required to confirm aneurysmal sac exclusion. The main objective of this study was to quantify and evaluate miRNA expression response to EVAR based on serum dosages at the 6-month follow-up. POPULATION AND METHOD 47 patients with indication for EVAR were recruited and 10 patients without comorbidities. miRNA-181b and miRNA-21 were selected for this study and their serum dosages were measured at two time points: preoperatively and after 6 months of follow-up, and only once in the control group. Demographic profiles, clinical follow-ups, and imaging examinations with angiotomography performed preoperatively and after 6 months were collected. RESULTS Overexpression of miRNA-181b and miRNA-21 was observed in the whole blood of patients with AAA. EVAR of patients with AAA resulted in decreased expression of the studied miRNAs, indicating that exclusion of the aneurysmal sac alters the expression of these markers. In addition, the expressions of miRNAs did not correlate with endoleaks or the diameter of the aneurysm or with the different types of devices used for the EVAR. CONCLUSIONS The overexpression of miRNA-181b, miRNA-21 with its reduction after EVAR, may suggest the use of these molecules as potential biomarkers in the follow-up of these patients. However, miRNAs were not able to identify possible endoleaks or discriminate them into subtypes. CLINICAL IMPACT The clinical application of the use of biomarkers in other areas such as oncology is already well established. In endovascular surgery it is still incipient although with great potential in daily practice, in order to anticipate or schedule possible interventions in patients with endoleak. In addition, understand the mechanisms of action of miRNAs in Atherosclerotic diseases and aortic syndromes could provide a better understanding of the pathophysiology as well as pharmacological development for AAA prevention as well as remodeling of the aneurysm sac after EVAR.
Collapse
Affiliation(s)
- Túlio Fabiano de Oliveira Leite
- Division of Vascular and Endovascular Surgery, Department of Surgery and Anatomy, Ribeirao Preto Medical School, Clinical Hospital of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Elpidio Ribeiro da Silva
- Division of Vascular and Endovascular Surgery, Department of Surgery and Anatomy, Ribeirao Preto Medical School, Clinical Hospital of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | - Karoline Evelyn
- Division of Vascular and Endovascular Surgery, Department of Surgery and Anatomy, Ribeirao Preto Medical School, Clinical Hospital of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| | | | - Edwaldo Edner Joviliano
- Division of Vascular and Endovascular Surgery, Department of Surgery and Anatomy, Ribeirao Preto Medical School, Clinical Hospital of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
2
|
Chun JY, de Haan M, Maleux G, Osman A, Cannavale A, Morgan R. CIRSE Standards of Practice on Management of Endoleaks Following Endovascular Aneurysm Repair. Cardiovasc Intervent Radiol 2024; 47:161-176. [PMID: 38216742 PMCID: PMC10844414 DOI: 10.1007/s00270-023-03629-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Accepted: 11/19/2023] [Indexed: 01/14/2024]
Abstract
BACKGROUND Endoleaks represent the most common complication after EVAR. Some types are associated with ongoing risk of aneurysm rupture and necessitate long-term surveillance and secondary interventions. PURPOSE This document, as with all CIRSE Standards of Practice documents, will recommend a reasonable approach to best practices of managing endoleaks. This will include imaging diagnosis, surveillance, indications for intervention, endovascular treatments and their outcomes. Our purpose is to provide recommendations based on up-to-date evidence, updating the guidelines previously published on this topic in 2013. METHODS The writing group was established by the CIRSE Standards of Practice Committee and consisted of clinicians with internationally recognised expertise in endoleak management. The writing group reviewed the existing literature performing a pragmatic evidence search using PubMed to select publications in English and relating to human subjects up to 2023. The final recommendations were formulated through consensus. RESULTS Endoleaks may compromise durability of the aortic repair, and long-term imaging surveillance is necessary for early detection and correct classification to guide potential re-intervention. The majority of endoleaks that require treatment can be managed using endovascular techniques. This Standards of Practice document provides up-to-date recommendations for the safe management of endoleaks.
Collapse
Affiliation(s)
- Joo-Young Chun
- St George's University Hospitals NHS Foundation Trust, London, UK.
- St George's University of London, London, UK.
| | - Michiel de Haan
- Maastricht University Medical Center, Maastricht, The Netherlands
| | | | - Asaad Osman
- St George's University Hospitals NHS Foundation Trust, London, UK
| | | | - Robert Morgan
- St George's University Hospitals NHS Foundation Trust, London, UK
- St George's University of London, London, UK
| |
Collapse
|
3
|
Masuda T, Baba Y, Nakaura T, Funama Y, Sato T, Masuda S, Gotanda R, Arao K, Imaizumi H, Arao S, Ono A, Hiratsuka J, Awai K. Applying patient characteristics, stent-graft selection, and pre-operative computed tomographic angiography data to a machine learning algorithm: Is endoleak prediction possible? Radiography (Lond) 2022; 28:906-911. [PMID: 35785641 DOI: 10.1016/j.radi.2022.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 05/28/2022] [Accepted: 06/06/2022] [Indexed: 10/31/2022]
Abstract
INTRODUCTION This study aims to predict endoleak after endovascular aneurysm repair (EVAR) using machine learning (ML) integration of patient characteristics, stent-graft configuration, and a selection of vessel lengths, diameters and angles measured using pre-operative computed tomography angiography (CTA). METHODS We evaluated 1-year follow-up CT scans (arterial and delayed phases) in patients who underwent EVAR for the presence or absence of an endoleak. We also obtained data on the patient characteristics, stent-graft selection, and preoperative CT vessel morphology (diameter, length, and angle). The extreme gradient boosting (XGBoost) for the ML system was trained on 30 patients with endoleaks and 81 patients without. We evaluated 5217 items in 111 patients with abdominal aortic aneurysms, including the patient characteristics, stent-graft configuration and vascular morphology acquired using pre-EVAR abdominal CTA. We calculated the area under the curve (AUC) of our receiver operating characteristic analysis using the ML method. RESULTS The AUC, accuracy, 95% confidence interval (CI), sensitivity, and specificity were 0.88, 0.88, 0.79-0.97, 0.85, and 0.91 for ML applying XGBoost, respectively. CONCLUSIONS The diagnostic performance of the ML method was useful when factors such as the patient characteristics, stent-graft configuration and vessel length, diameter and angle of the vessels were considered from pre-EVAR CTA. IMPLICATIONS FOR PRACTICE Based on our findings, we suggest that this is a potential application of ML for the interpretation of abdominal CTA scans in patients with abdominal aortic aneurysms scheduled for EVAR.
Collapse
Affiliation(s)
- T Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan.
| | - Y Baba
- Department of Diagnostic Radiology, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka-City, Saitama-Pref 350-1298, Japan
| | - T Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Y Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - T Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - S Masuda
- Department of Radiological Technology, Kawamura Clinic, Otemachi, Naka-ku, Hiroshima 730-0051, Japan
| | - R Gotanda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - H Imaizumi
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - S Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - A Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - J Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama, 701-0193, Japan
| | - K Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
4
|
Jessula S, Eagleton MJ. Conversion of failed endovascular infrarenal aortic aneurysm repair with fenestrated/branched stent grafts. Semin Vasc Surg 2022; 35:341-349. [DOI: 10.1053/j.semvascsurg.2022.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 06/23/2022] [Accepted: 06/27/2022] [Indexed: 11/11/2022]
|
5
|
Boer GJ, Schröder LBW, Disli MC, Kuijper TM, van de Luijtgaarden KM, Fioole B. A stable aneurysm sac after endovascular aneurysm repair as a predictor for mortality, an in-depth analysis. J Vasc Surg 2022; 76:445-453. [PMID: 35149164 DOI: 10.1016/j.jvs.2022.01.125] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 01/21/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study was to compare the long-term survival in patients with a stable aneurysmal sac and those with aneurysmal sac regression after endovascular aneurysm repair (EVAR) and to identify independent risk factors for aneurysmal sac regression and mortality after EVAR. METHODS We reviewed all patients who underwent EVAR between 2005 and 2018 with a computed tomography angiography available at 1-year follow-up. Aneurysm sac regression was defined as a diameter decrease of more than 10%. We used a multivariable regression to identify independent risk factors for sac regression. Kaplan-Meier analysis and Cox regression were done to test differences in 5-year mortality between a stable sac and sac regression. RESULTS The inclusion criteria were met by 325 patients, 185 in the sac regression group and 140 in the stable sac group. Multivariable logistic regression analysis showed that treatment for a ruptured aneurysm was an independent risk factor for aneurysmal sac regression (hazard ratio [HR], 0.26; 95% confidence interval [CI], 0.07-0.96). Age (HR, 1.05; 95% CI, 1.01-1.09), ischemic heart disease (HR, 1.94; 95% CI, 1.13-3.31), neck thrombus (HR, 2.72; 95% CI, 1.07-6.95), and a type II endoleak (HR, 19.21; 95% CI, 7.32-50.40) were independent risk factors for a stable aneurysm sac diameter. Multivariable Cox regression showed a significantly increased risk of mortality for patients with a stable aneurysm sac after EVAR (odds ratio, 2.25; 95% CI, 1.36-3.72). There was no significant difference in cause of death between the two groups. CONCLUSION A stable aneurysm sac after EVAR is associated with increased mortality. Age, ischemic heart disease, neck thrombus, and a type II endoleak are independent risk factors for a stable sac. However, a well-founded explanation for this finding is still lacking. Future research should be focussed on aggressive treatment of type II endoleaks and inflammatory processes as potential pathophysiological mechanisms.
Collapse
Affiliation(s)
- Gert Jan Boer
- Department of Vascular Surgery, Maasstad Hospital, Rotterdam, the Netherlands.
| | | | - Maksud C Disli
- Department of Vascular Surgery, Maasstad Hospital, Rotterdam, the Netherlands
| | - Tjallingius M Kuijper
- Clinical epidemiologist and statistician, Maasstad Academy, Maasstad Hospital, Rotterdam, the Netherlands
| | | | - Bram Fioole
- Department of Vascular Surgery, Maasstad Hospital, Rotterdam, the Netherlands
| |
Collapse
|
6
|
Zhang S, Laubrie JD, Mousavi SJ, Avril S. 3D finite-element modeling of vascular adaptation after endovascular aneurysm repair. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3547. [PMID: 34719114 DOI: 10.1002/cnm.3547] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 10/27/2021] [Indexed: 06/13/2023]
Abstract
Aneurysm shrinkage is clinically observed after successful endovascular aortic aneurysm repair (EVAR). However, global understanding of post-operative aneurysm evolutions remains weak. In this work, we propose to study these effects using numerical simulation. We set up a 3D finite-element model of post-EVAR vascular adaptation within an open-source finite-element code, which was initially developed for growth and remodeling (G&R). We modeled the endograft with a set of uniaxial prestrained springs that apply radial forces on the inner surface of the artery. Constitutive equations, momentum balance equations, and equations related to the mechanobiology of the artery were formulated based on the homogenized constrained mixture theory. We performed a sensitivity analysis by varying different selected parameters, namely oversizing and compliance of the stent-graft, gain parameters related to collagen G&R, and the residual pressure in the aneurysm sac. This permitted us to evaluate how each factor influences post-EVAR vascular adaptation. It was found that oversizing, compliance or gain parameters have a limited influence compared to that of the residual pressure in the aneurysm sac, which was found to play a critical role in the stability of aneurysm after stent-graft implantation. An excessive residual pressure larger than 50 mmHg can induce a continuous expansion of the aneurysm while a moderate residual pressure below this critical threshold yields continuous shrinkage of the aneurysm. Moreover, it was found that elderly patients, with relatively lower amounts of remnant elastin in the arterial wall, are more sensitive to the effect of residual pressure. Therefore, these results show that elderly patients may present a higher potential risk of aortic sac expansion due to intra-aneurysm sac pressure after EVAR than younger patients.
Collapse
Affiliation(s)
- Shaojie Zhang
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Saint-Étienne, France
| | - Joan D Laubrie
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Saint-Étienne, France
| | - S Jamaleddin Mousavi
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Saint-Étienne, France
| | - Stéphane Avril
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Saint-Étienne, France
| |
Collapse
|
7
|
Major M, Long GW, Eden CL, Studzinski DM, Callahan RE, Brown OW. Long-term outcomes and interventions of postoperative type 1a endoleak following elective endovascular aortic aneurysm repair. J Vasc Surg 2021; 75:136-143.e1. [PMID: 34324969 DOI: 10.1016/j.jvs.2021.07.122] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 07/15/2021] [Indexed: 12/01/2022]
Abstract
OBJECTIVE This study evaluated the incidence and long-term outcomes of postoperative type 1a endoleak (PT1a) following endovascular aortic aneurysm repair (EVAR). METHODS A retrospective review of consecutive aorto-iliac EVARs performed at a single institution from June 2006 to June 2012 was conducted. Patients with PT1a were identified by postoperative imaging and compared with those who did not develop a PT1a. Late outcomes were also studied of a subset of patients with PT1a who had persistent intraoperative type 1a endoleak (iT1a) on completion angiogram during EVAR that had resolved on initial follow-up imaging. RESULTS Three hundred eighty-nine patients underwent EVAR with median follow-up of 87 months (interquartile range, 64-111 months). The incidence of PT1a was 8.2% (n = 32) with a median follow-up of 74 months (interquartile range, 52-138 months). Compared with the total cohort, those who developed PT1a were statistically more likely to be female (32% vs 17%; P = .03) and have a higher all-cause mortality (71% vs 40%; P < .01) and aneurysm-related mortality (15.6% vs 1.7%; P < .01). Median time to presentation was 52 months. Of the 32 patients with PT1a, five (15.6%) presented with aortic rupture, of which three underwent extension cuff placement, one had open graft explant, and one declined intervention. Six patients in total (18.7%) declined intervention; five of these died of nonaneurysmal causes and one remains alive. Of the 26 patients with PT1a who had intervention, 21 (80.7%) showed resolution of PT1a, and five (19.2%) had recurrence. For patients with recurrent PT1a, two had resulting aneurysm-related mortality, two endoleaks resolved after relining with an endograft, and one patient declined intervention but remains alive. Patients with PT1a who had intervention with resolution showed no significant difference in median survival estimates (140.0 months) compared with the remaining EVAR cohort (120.0 months; P = .80). Within the PT1a cohort, 6 (18.7%) had also experienced iT1a with a mean time to presentation of the late PT1a of 45 months. iT1a was associated with a significantly increased likelihood of developing a PT1a (P < .01) and decreased median survival (P < .01), but there was no known aneurysm-related mortality. CONCLUSIONS Development of PT1a following elective EVAR is associated with increased all-cause and aneurysm-related mortality and presents an average of 52 months postoperatively. This underscores the importance of long-term surveillance. Patients with PT1a who had a successful intervention showed no significant difference in median survival. Those with iT1a had a higher risk for PT1a compared with the EVAR cohort overall and had decreased median survival, without increased aneurysm-related mortality.
Collapse
Affiliation(s)
- Matthew Major
- Department of Surgery, Beaumont Health, Royal Oak, Mich
| | - Graham W Long
- Department of Surgery, Beaumont Health, Royal Oak, Mich.
| | | | | | | | | |
Collapse
|
8
|
Verbist J, Peeters P, Bosiers M, Deferm H, Haenen L, Vermaercke M, Vercaeren P. Endoleaks after Endoluminal Repair of Abdominal Aortic Aneurysms : Diagnosis and Treatment. Acta Chir Belg 2020. [DOI: 10.1080/00015458.2001.12098607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
| | | | - M. Bosiers
- St.-Blasius Hospital, Dendermonde, Belgium
| | | | | | | | | |
Collapse
|
9
|
Gaffey AC, Damrauer SM. Evolving Concepts, Management, and Treatment of Type 1 Endoleaks after Endovascular Aneurysm Repair. Semin Intervent Radiol 2020; 37:395-404. [PMID: 33041486 DOI: 10.1055/s-0040-1715883] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Over the past 20 years, there has been tremendous progress in endovascular aneurysm repair techniques and devices. The application of new third- and fourth-generation devices (from 2003 onward) has led to changes in the incidence and management of endoleaks. This comprehensive review aims to outline the most recent concepts with respect to pathophysiology/risk factors and management of Type 1 endoleaks.
Collapse
Affiliation(s)
- Ann C Gaffey
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Perlman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Scott M Damrauer
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Perlman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
10
|
Chaudhuri A, Badawy A. Endograft platform does not influence aortic neck dilatation after infrarenal endovascular aneurysm repair with primary endostapling. Vascular 2020; 29:315-322. [PMID: 32970536 DOI: 10.1177/1708538120958837] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVES Aortic endografts used for endovascular aneurysm repair (EVAR) are based on varying skeletal platforms such as stainless steel or nitinol stents, using radial force applied to seal at the aneurysm neck, and varying proximal fixation methods, applying either suprarenal or infrarenal fixation. This study assesses whether varying skeleton/fixation platforms affect neck-related outcomes after primary endostapling with Heli-FX EndoAnchors at EVAR. METHODS Retrospective analysis of a prospective database of infrarenal EVAR undertaken at a single centre. Chimney-EVAR, secondary cases were excluded. Primary outcomes analysed included neck diameter evolution from pre-EVAR to latest imaging follow-up, including a comparison of stent platforms to see if there was any outcome difference between those using stainless steel or nitinol, as also freedom from type I endoleakage and migration. Secondary outcomes assessed included average number of EndoAnchors, and sac size patterns before and after EVAR. RESULTS A total of 101 patients underwent endostapled infrarenal EVAR between September 2013 and March 2020. After exclusion of ineligible patients, 84 patients (76 male, 8 female, age 73.7 ± 7.8 years) were available for analysis. 57/27 endografts used suprarenal/infrarenal fixation, whilst 16/68 devices were based on stainless steel/nitinol platforms, respectively. Mean oversizing was higher for stainless steel/suprarenal fixation endografts (p = 0.02). A total of 582 EndoAnchors were deployed, averaging 7 ± 2 per patient. Median neck diameter was 25 mm (IQR 22-31) with 22 necks having non-parallel morphology (conical, tapered or bubble). Median follow-up period was 28.5 (IQR 12-43) months. Neck evolution studies suggested aortic neck dilatation of 5 ± 4 mm (p <0.001, paired T-test), independent of platforms employed (p = NS, ANOVA). There was no endograft migration; one immediate post-EVAR endoleak settled by eight weeks. There was a mean 5.7 ± 8.2 mm sac size reduction (p < 0.001, paired T-test). CONCLUSION Aortic neck dilatation occurs after EVAR with primary endostapling, but the process may be independent of stainless steel/nitinol platforms, possibly due to the attenuating effect of EndoAnchors. Adjunct aneurysm neck fixation by primary endostapling prevents migration regardless of whether suprarenal/infrarenal fixation is the primary fixative method. Device platform choice therefore may be left to the operator discretion if primary endostapling is applied at EVAR. Freedom from complications such as migration and endoleakage in the intermediate term suggests a higher level of 'tolerance' to aortic neck dilatation with primary endostapling. We would therefore suggest routine usage of EndoAnchors at EVAR when not otherwise contraindicated.
Collapse
Affiliation(s)
- Arindam Chaudhuri
- Bedfordshire - Milton Keynes Vascular Centre, Bedfordshire Hospitals NHS Foundation Trust, Kempston Road, Bedford MK42 9DJ, UK
| | - Ayman Badawy
- Bedfordshire - Milton Keynes Vascular Centre, Bedfordshire Hospitals NHS Foundation Trust, Kempston Road, Bedford MK42 9DJ, UK
| |
Collapse
|
11
|
Kizilski SB, Amili O, Coletti F, Faizer R, Barocas VH. Conceptual Framework Development for a Double-Walled Aortic Stent-Graft to Manage Blood Pressure. J Med Device 2020; 14:031005. [PMID: 32983314 DOI: 10.1115/1.4047873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 06/03/2020] [Indexed: 11/08/2022] Open
Abstract
A double-walled stent-graft (DWSG) design with a compressible gas layer was conceived with the goal of treating hypertension in patients receiving an aortic stent-graft. Early prototypes were developed to evaluate the design concept through static measurements from a finite element (FE) model and quasi-static inflation experiments, and through dynamic measurements from an in vitro flow loop and the three-element Windkessel model. The amount of gas in the gas layer and the properties of the flexible inner wall were the primary variables evaluated in this study. Properties of the inner wall had minimal effect on DWSG behavior, but increased gas charge led to increased fluid capacitance and larger reduction in peak and pulse pressures. In the flow loop, placement of the DWSG decreased pulse pressure by over 20% compared to a rigid stent-graft. Capacitance measurements were consistent across all methods, with the maximum capacitance estimated at 0.07 mL/mmHg for the largest gas charge in the 15 cm long prototype. Windkessel model predictions for in vivo performance of a DWSG placed in the aorta of a hypertensive patient showed pulse pressure reduction of 14% compared to a rigid stent-graft case, but pressures never returned to unstented values. These results indicate that the DWSG design has potential to be developed into a new treatment for hypertensive patients requiring an aortic intervention.
Collapse
Affiliation(s)
- Shannen B Kizilski
- Department of Mechanical Engineering, University of Minnesota, 312 Church Street SE Hasselmo Hall, 7-105, Minneapolis, MN 55455
| | - Omid Amili
- Department of Aerospace Engineering and Mechanics, University of Minnesota, 110 Union Street SE Akerman Hall, Minneapolis, MN 55455
| | - Filippo Coletti
- Department of Aerospace Engineering and Mechanics, University of Minnesota, 110 Union Street SE Akerman Hall, Minneapolis, MN 55455
| | - Rumi Faizer
- Department of Surgery, University of Minnesota, 909 Fulton Street SE, Minneapolis, MN 55455
| | - Victor H Barocas
- Department of Biomedical Engineering, University of Minnesota, 312 Church Street SE Hasselmo Hall, 7-105, Minneapolis, MN 55455
| |
Collapse
|
12
|
Bando Y, Kitase M, Shimohira M, Honda J, Furuta Y, Kasuya A, Imada H, Mizutani M, Shibamoto Y. 2D-shear wave elastography in the prediction of type II endoleaks after endovascular aneurysm repair. MINIM INVASIV THER 2019; 30:21-26. [PMID: 31621439 DOI: 10.1080/13645706.2019.1678174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To evaluate the usefulness of 2D-shear wave elastography (2D-SWE) in the prediction of type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAA). MATERIAL AND METHODS Twenty-nine patients underwent EVAR for AAA, and 2D-SWE was performed after EVAR. Follow-up contrast-enhanced CT and ultrasonography were performed to evaluate endoleaks in all patients. The median follow-up period was 12 months (range, 3-12 months). Patients were divided into two groups: one with an endoleak (endoleak group) and another without it (control group). We compared the elasticity index (EI) of intraluminal thrombus (ITL) and fresh thrombus (FT) between the two groups. RESULTS Type II endoleaks were confirmed in five of the 29 patients (endoleak group), and there were no endoleaks in the other 24 (control group). ILT was observed in 21 patients of the control group and in all patients of the endoleak group. There was a difference only in EI of ILT; the mean EI (± standard deviation) of ILT was 89 ± 16 kPA in the control group and 113 ± 25 kPA in the endoleak group (p=.037). CONCLUSIONS High EI of ILT may predict the occurrence of type II endoleaks after EVAR of AAA.
Collapse
Affiliation(s)
- Yuya Bando
- Department of Radiology, Konan Kosei Hospital, Aichi, Japan
| | - Masanori Kitase
- Department of Radiology, Kariya Toyota General Hospital, Aichi, Japan
| | - Masashi Shimohira
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Junichi Honda
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Yoshiteru Furuta
- Department of Radiology, Kariya Toyota General Hospital, Aichi, Japan
| | - Akihiro Kasuya
- Central Division of Radiology, Kariya Toyota General Hospital, Aichi, Japan
| | - Hidenao Imada
- Central Division of Radiology, Kariya Toyota General Hospital, Aichi, Japan
| | - Masaru Mizutani
- Department of Radiology, Kariya Toyota General Hospital, Aichi, Japan
| | - Yuta Shibamoto
- Department of Radiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| |
Collapse
|
13
|
The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg 2018; 67:2-77.e2. [DOI: 10.1016/j.jvs.2017.10.044] [Citation(s) in RCA: 1768] [Impact Index Per Article: 252.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
14
|
Select early type IA endoleaks after endovascular aneurysm repair will resolve without secondary intervention. J Vasc Surg 2018; 67:119-125. [DOI: 10.1016/j.jvs.2017.05.096] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Accepted: 05/05/2017] [Indexed: 11/21/2022]
|
15
|
Abraha I, Luchetta ML, De Florio R, Cozzolino F, Casazza G, Duca P, Parente B, Orso M, Germani A, Eusebi P, Montedori A, Cochrane Vascular Group. Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair. Cochrane Database Syst Rev 2017; 6:CD010296. [PMID: 28598495 PMCID: PMC6481872 DOI: 10.1002/14651858.cd010296.pub2] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND People with abdominal aortic aneurysm who receive endovascular aneurysm repair (EVAR) need lifetime surveillance to detect potential endoleaks. Endoleak is defined as persistent blood flow within the aneurysm sac following EVAR. Computed tomography (CT) angiography is considered the reference standard for endoleak surveillance. Colour duplex ultrasound (CDUS) and contrast-enhanced CDUS (CE-CDUS) are less invasive but considered less accurate than CT. OBJECTIVES To determine the diagnostic accuracy of colour duplex ultrasound (CDUS) and contrast-enhanced-colour duplex ultrasound (CE-CDUS) in terms of sensitivity and specificity for endoleak detection after endoluminal abdominal aortic aneurysm repair (EVAR). SEARCH METHODS We searched MEDLINE, Embase, LILACS, ISI Conference Proceedings, Zetoc, and trial registries in June 2016 without language restrictions and without use of filters to maximize sensitivity. SELECTION CRITERIA Any cross-sectional diagnostic study evaluating participants who received EVAR by both ultrasound (with or without contrast) and CT scan assessed at regular intervals. DATA COLLECTION AND ANALYSIS Two pairs of review authors independently extracted data and assessed quality of included studies using the QUADAS 1 tool. A third review author resolved discrepancies. The unit of analysis was number of participants for the primary analysis and number of scans performed for the secondary analysis. We carried out a meta-analysis to estimate sensitivity and specificity of CDUS or CE-CDUS using a bivariate model. We analysed each index test separately. As potential sources of heterogeneity, we explored year of publication, characteristics of included participants (age and gender), direction of the study (retrospective, prospective), country of origin, number of CDUS operators, and ultrasound manufacturer. MAIN RESULTS We identified 42 primary studies with 4220 participants. Twenty studies provided accuracy data based on the number of individual participants (seven of which provided data with and without the use of contrast). Sixteen of these studies evaluated the accuracy of CDUS. These studies were generally of moderate to low quality: only three studies fulfilled all the QUADAS items; in six (40%) of the studies, the delay between the tests was unclear or longer than four weeks; in eight (50%), the blinding of either the index test or the reference standard was not clearly reported or was not performed; and in two studies (12%), the interpretation of the reference standard was not clearly reported. Eleven studies evaluated the accuracy of CE-CDUS. These studies were of better quality than the CDUS studies: five (45%) studies fulfilled all the QUADAS items; four (36%) did not report clearly the blinding interpretation of the reference standard; and two (18%) did not clearly report the delay between the two tests.Based on the bivariate model, the summary estimates for CDUS were 0.82 (95% confidence interval (CI) 0.66 to 0.91) for sensitivity and 0.93 (95% CI 0.87 to 0.96) for specificity whereas for CE-CDUS the estimates were 0.94 (95% CI 0.85 to 0.98) for sensitivity and 0.95 (95% CI 0.90 to 0.98) for specificity. Regression analysis showed that CE-CDUS was superior to CDUS in terms of sensitivity (LR Chi2 = 5.08, 1 degree of freedom (df); P = 0.0242 for model improvement).Seven studies provided estimates before and after administration of contrast. Sensitivity before contrast was 0.67 (95% CI 0.47 to 0.83) and after contrast was 0.97 (95% CI 0.92 to 0.99). The improvement in sensitivity with of contrast use was statistically significant (LR Chi2 = 13.47, 1 df; P = 0.0002 for model improvement).Regression testing showed evidence of statistically significant effect bias related to year of publication and study quality within individual participants based CDUS studies. Sensitivity estimates were higher in the studies published before 2006 than the estimates obtained from studies published in 2006 or later (P < 0.001); and studies judged as low/unclear quality provided higher estimates in sensitivity. When regression testing was applied to the individual based CE-CDUS studies, none of the items, namely direction of the study design, quality, and age, were identified as a source of heterogeneity.Twenty-two studies provided accuracy data based on number of scans performed (of which four provided data with and without the use of contrast). Analysis of the studies that provided scan based data showed similar results. Summary estimates for CDUS (18 studies) showed 0.72 (95% CI 0.55 to 0.85) for sensitivity and 0.95 (95% CI 0.90 to 0.96) for specificity whereas summary estimates for CE-CDUS (eight studies) were 0.91 (95% CI 0.68 to 0.98) for sensitivity and 0.89 (95% CI 0.71 to 0.96) for specificity. AUTHORS' CONCLUSIONS This review demonstrates that both ultrasound modalities (with or without contrast) showed high specificity. For ruling in endoleaks, CE-CDUS appears superior to CDUS. In an endoleak surveillance programme CE-CDUS can be introduced as a routine diagnostic modality followed by CT scan only when the ultrasound is positive to establish the type of endoleak and the subsequent therapeutic management.
Collapse
Affiliation(s)
- Iosief Abraha
- Regional Health Authority of UmbriaHealth Planning ServicePerugiaItaly06124
| | | | - Rita De Florio
- Local Health UnitAzienda SanitariaLocale USL 1, Medicina GeneralePerugiaItaly
| | - Francesco Cozzolino
- Regional Health Authority of UmbriaVia Mario Angeloni 61PerugiaUnbriaItaly06124
| | - Giovanni Casazza
- Università degli Studi di MilanoDipartimento di Scienze Biomediche e Cliniche "L. Sacco"via GB Grassi 74MilanItaly20157
| | - Piergiorgio Duca
- Ospedale Luigi SaccoL.I.T.A. Polo UniversitarioVia G.B. Grassi, 74MilanoItaly20157
| | - Basso Parente
- Azienda Ospedaliera di PerugiaChirurgia VascolareSant' Andrea delle FrattePerugiaItaly06156
| | - Massimiliano Orso
- Regional Health Authority of UmbriaHealth Planning ServicePerugiaItaly06124
| | - Antonella Germani
- Azienda Unita' Sanitaria Locale Umbria N. 2Servizio Immunotrasfusionalevia ArcamoneFolignoItaly06034
| | - Paolo Eusebi
- Regional Health Authority of UmbriaEpidemiology DepartmentVia Mario Angeloni 61PerugiaUmbriaItaly06124
| | | | | |
Collapse
|
16
|
Preoperative Inferior Mesenteric Artery Embolization: A Valid Method to Reduce the Rate of Type II Endoleak after EVAR? Ann Vasc Surg 2016; 39:40-47. [PMID: 27531083 DOI: 10.1016/j.avsg.2016.05.106] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Revised: 03/01/2016] [Accepted: 05/11/2016] [Indexed: 11/21/2022]
Abstract
BACKGROUND Type II endoleak is the most commonly encountered endoleak after endovascular abdominal aortic aneurysm repair (EVAR). Some have advocated preoperative inferior mesenteric artery (IMA) embolization as a valid method for reducing the incidence of this endoleak, but controversies exist. We sought to demonstrate the impact of IMA embolization using a meta-analysis of currently available studies combined with our own experience. METHODS We conducted an institutional review board-approved, retrospective analysis of all patients undergoing IMA embolization before EVAR between the years 2010 and 2015 and used as a control a similar group of patients with patent IMA. We divided patients from our own experience and 5 other studies into 2 groups: those who did not undergo IMA embolization (control) before EVAR and those who did. Rates of type II endoleaks, aneurysm sac regression, and secondary interventions were analyzed. RESULTS A total of 620 patients from 6 studies were analyzed, including 258 patients who underwent an attempted IMA embolization before EVAR with a cumulative success rate of 99.2% (range, 93.8% to 100%). There was 1 fatality associated with IMA embolization. A meta-analysis showed that preoperative IMA embolization protected against type II endoleaks compared to the control group (odds ratio [OR], 0.31 [0.17-0.57]; P < 0.001, I2 = 43%). Furthermore, the rate of secondary intervention was significantly lower in the treatment group (OR, 0.12 [0.004-0.36]; P < 0.001, I2 = 0%). After IMA embolization, type II endoleak resulted from patent lumbar arteries in all 62 patients with persistent endoleak. CONCLUSIONS Preoperative embolization of the IMA protects against the development of type II endoleaks and secondary interventions and may potentially lead to a rapid aneurysm sac regression. The procedure can be performed with a high technical success rate and minimal complications and should be considered in patients with IMA >3 mm before EVAR. A randomized trial, however, is required to clearly delineate the clinical significance of this technique.
Collapse
|
17
|
White GH, May J, Waugh RC, Chaufour X, Yu W. Type III and Type IV Endoleak: Toward a Complete Definition of Blood Flow in the Sac after Endoluminal AAA Repair. J Endovasc Ther 2016; 5:305-9. [PMID: 9867318 DOI: 10.1177/152660289800500403] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
In this document the authors continue to refine their seminal categorization of endoleak, a major complication of endovascular aneurysm repair. In addition to type I (related to the graft device itself) and type II (retrograde flow from collateral branches) endoleak, they propose two new categories: endoleak due to fabric tears, graft disconnection, or disintegration would be classified type III, and flow through the graft presumed to be associated with graft wall “porosity” would be categorized as type IV endoleak.
Collapse
Affiliation(s)
- G H White
- Department of Vascular Surgery, Royal Prince Alfred Hospital, University of Sydney, NSW, Australia.
| | | | | | | | | |
Collapse
|
18
|
Gawenda M, Winter S, Jaschke G, Wassmer G, Brunkwall J. Endotension is Influenced by Aneurysm Volume: Experimental Findings. J Endovasc Ther 2016; 10:1091-6. [PMID: 14723580 DOI: 10.1177/152660280301000611] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To investigate in an in vitro model whether and to what extent pressure is influenced by aneurysm size. Methods: Latex aneurysms of 3 different volumes (24, 30, and 81 mL) were inserted into an in vitro circulation model. The systemic mean pressure (SPmean) was varied from 50 to 120 mmHg. The aneurysms were excluded using a woven polyethylene graft. Aneurysm sac mean pressure (ASPmean) was measured. Results: In the in vitro model, endovascular aneurysm repair created a closed chamber without endoleak but showed a relevant aneurysm sac pressure. At an SPmean of 80 mmHg, the ASPmean was 42.0 ± 0.6 mmHg in the 24-mL aneurysm, 40.5 ± 0.5 mmHg in the 30-mL model, and 19.3 ± 0.5 mmHg in the 81-mL aneurysm (p < 0.05). The ASPmean rose with increasing SPmean and was inversely dependent on the aneurysm volume. Conclusions: This in vitro model demonstrated that the sac mean pressure correlated to the systemic pressure and that a greater aneurysm volume reduced aneurysm sac pressure. These data highlight the need for further studies regarding endotension.
Collapse
Affiliation(s)
- Michael Gawenda
- Division of Vascular Surgery, Department of Surgery, Medical Centre, University of Cologne, Germany.
| | | | | | | | | |
Collapse
|
19
|
Walker SR, Macierewicz J, Hopkinson BR. Endovascular AAA Repair: Prevention of Side Branch Endoleaks with Thrombogenic Sponge. J Endovasc Ther 2016. [DOI: 10.1177/152660289900600410] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To report a technique that might decrease the incidence of lumbar artery endoleaks following endovascular repair (EVR) of abdominal aortic aneurysms (AAAs). Methods: Ninety-three patients (86 males, median age 72 years, range 56 to 88) undergoing EVR with the aortomonoiliac technique were entered into a study to detect and then occlude patent side branches before completion of the endografting procedure. Prior to deploying the iliac occluder, an aneurysmogram was performed to detect patent aortic side branches. If these side branches were found, an absorbable gelatin sponge was inserted into the aneurysm sac via the occluder introducer sheath. The patients were followed with contrast-enhanced spiral computed tomography (CT) at 1 week and 3, 6, and 12 months to detect the presence of endoleaks. Results: Forty-eight (52%) patients demonstrated patent side branches that were occluded by the insertion of gelatin sponges into the aneurysm sac. The remaining 45 patients without evidence of side branch flow were untreated. Ten (10.7%) patients died in the perioperative period, and 15 (16.1%) primary endoleaks (13 proximal, 2 distal) were detected. This left 68 (73.1%) patients for follow-up, 33 (48.5%) of whom had patent branch vessels treated with the thrombogenic sponge. The median follow-up was 4 months (range 1 to 17), during which time no side branch endoleak was detected on surveillance CT scans in any of the 68 patients, which included all patients treated with the thrombogenic sponge technique and those in whom no patent side branches had been identified. Conclusions: We have demonstrated a safe and reliable method of preventing lumbar artery endoleaks following endovascular AAA repair.
Collapse
Affiliation(s)
- Stuart R. Walker
- Department of Vascular and Endovascular Surgery, Queen's Medical Centre, Nottingham, United Kingdom
| | - Jan Macierewicz
- Department of Vascular and Endovascular Surgery, Queen's Medical Centre, Nottingham, United Kingdom
| | - Brian R. Hopkinson
- Department of Vascular and Endovascular Surgery, Queen's Medical Centre, Nottingham, United Kingdom
| |
Collapse
|
20
|
Ramaiah VG, Thompson CS, Rodriguez-Lopez JA, DiMugno L, Olsen D, Diethrich EB. Endovascular Repair of AAA Rupture 20 Months after Endoluminal Stent-Grafting. J Endovasc Ther 2016; 8:125-30. [PMID: 11357970 DOI: 10.1177/152660280100800204] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To demonstrate the feasibility of endovascular repair of a ruptured abdominal aortic aneurysm (AAA) previously treated with an endoluminal stent-graft. Case Report: An 84-year-old man with a 9.5-cm AAA underwent endoluminal repair with an Endologix stent-graft, but a type I endoleak was detected postprocedurally. The patient was discharged and lost to follow-up. Twenty months later, he suffered an aneurysm rupture, which was repaired using endovascular techniques. Although he had a postoperative course complicated by aspiration pneumonia and renal failure, he recovered fully and was discharged from the hospital with no evidence of endoleak on the postprocedural imaging studies. Conclusions: Late ruptures after endoluminal AAA stent-grafting can be successfully treated with endovascular techniques.
Collapse
Affiliation(s)
- V G Ramaiah
- Department of Cardiovascular and Endovascular Surgery, Arizona Heart Institute and Hospital, Phoenix 85016, USA.
| | | | | | | | | | | |
Collapse
|
21
|
In-plane mechanics of soft architectured fibre-reinforced silicone rubber membranes. J Mech Behav Biomed Mater 2014; 40:339-353. [PMID: 25265032 DOI: 10.1016/j.jmbbm.2014.09.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Revised: 09/01/2014] [Accepted: 09/08/2014] [Indexed: 11/22/2022]
Abstract
Silicone rubber membranes reinforced with architectured fibre networks were processed with a dedicated apparatus, allowing a control of the fibre content and orientation. The membranes were subjected to tensile loadings combined with continuous and discrete kinematical field measurements (DIC and particle tracking). These tests show that the mechanical behaviour of the membranes is hyperelastic at the first order. They highlight the influence of the fibre content and orientation on both the membrane in-plane deformation and stress levels. They also prove that for the considered fibrous architectures and mechanical loadings, the motion and deformation of fibres is an affine function of the macroscale transformation. These trends are fairly well described by the micromechanical model proposed recently in Bailly et al. (JMBBM, 2012). This result proves that these materials are very good candidates for new biomimetic membranes, e.g. to improve aortic analogues used for in vitro experiments, or existing textiles used for vascular (endo)prostheses.
Collapse
|
22
|
Clemens MS, Scott DJ, Stull MC, Hislop SJ, Propper BW, Arthurs ZM. A technique for endograft relining of a type IV endoleak using a surgeon-modified internal gate. Ann Vasc Surg 2014; 29:123.e13-7. [PMID: 25220344 DOI: 10.1016/j.avsg.2014.07.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 06/23/2014] [Accepted: 07/27/2014] [Indexed: 11/19/2022]
Abstract
Type IV endoleaks represent a rare etiology of late endograft failure; however, depending on the location, they can be extremely challenging to repair with endovascular solutions. We present a method of endograft relining that preserves antegrade limb perfusion, avoids extra-anatomic reconstructions, and ensures complete endograft exclusion.
Collapse
Affiliation(s)
- Michael S Clemens
- Department of Vascular Surgery, San Antonio Military Medical Center, San Antonio, TX.
| | - Daniel J Scott
- Department of Vascular Surgery, San Antonio Military Medical Center, San Antonio, TX
| | - Mamie C Stull
- Department of Vascular Surgery, San Antonio Military Medical Center, San Antonio, TX
| | - Sean J Hislop
- Department of Vascular Surgery, San Antonio Military Medical Center, San Antonio, TX
| | - Brandon W Propper
- Department of Vascular Surgery, San Antonio Military Medical Center, San Antonio, TX
| | - Zachary M Arthurs
- Department of Vascular Surgery, San Antonio Military Medical Center, San Antonio, TX
| |
Collapse
|
23
|
Chung R, Morgan RA. Type 2 Endoleaks Post-EVAR: Current Evidence for Rupture Risk, Intervention and Outcomes of Treatment. Cardiovasc Intervent Radiol 2014; 38:507-22. [PMID: 25189665 DOI: 10.1007/s00270-014-0987-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Accepted: 07/26/2014] [Indexed: 10/24/2022]
Abstract
Type 2 endoleaks (EL2) are the most commonly encountered endoleaks following EVAR. Despite two decades of experience, there remains considerable variation in the management of EL2 with controversies ranging from if to treat, when to treat and how to treat. Here, we summarise the available evidence, describe the treatment techniques available and offer guidelines for management.
Collapse
Affiliation(s)
- Raymond Chung
- Radiology, Ground Floor, St. James Wing, St. George's Healthcare NHS Trust, Blackshaw Road, Tooting, London, SW17 0QT, England, UK,
| | | |
Collapse
|
24
|
|
25
|
Bailly L, Deplano V, Lemercier A, Boiron O, Meyer C. New experimental protocols for tensile testing of abdominal aortic analogues. Med Eng Phys 2014; 36:800-4. [DOI: 10.1016/j.medengphy.2014.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2013] [Revised: 12/17/2013] [Accepted: 02/06/2014] [Indexed: 11/28/2022]
|
26
|
CHAGNON GREGORY, GAUDIN VINCENT, FAVIER DENIS, ORGEAS LAURENT, CINQUIN PHILIPPE. AN OSMOTICALLY INFLATABLE SEAL TO TREAT ENDOLEAKS OF TYPE 1, FOLLOWING ENDOVASCULAR ANEURYSM REPAIR. J MECH MED BIOL 2012. [DOI: 10.1142/s0219519412004958] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Stent-grafts of various designs are currently used in endoluminal treatment of abdominal aortic aneurysm. Two of the remaining possible complications are endoleaks and stent migrations. To treat endoleaks of type 1, a new system is studied here: An inflatable osmotic seal. It is set up at the extremities of the endograft and swollen using osmotic process against the vessels in case of endoleak without any invasive re-intervention. Mechanical modeling of the device and finite element simulations are performed to evaluate the efficiency of the seal and the consequences on the arteries as function of the osmotic pressure.
Collapse
Affiliation(s)
- GREGORY CHAGNON
- Université de Grenoble/CNRS, Laboratoire Sols, Solides, Structures, Risques, BP 53 - 38041 Grenoble Cedex 9, France
| | - VINCENT GAUDIN
- Université de Grenoble/CNRS, Laboratoire Sols, Solides, Structures, Risques, BP 53 - 38041 Grenoble Cedex 9, France
| | - DENIS FAVIER
- Université de Grenoble/CNRS, Laboratoire Sols, Solides, Structures, Risques, BP 53 - 38041 Grenoble Cedex 9, France
| | - LAURENT ORGEAS
- Université de Grenoble/CNRS, Laboratoire Sols, Solides, Structures, Risques, BP 53 - 38041 Grenoble Cedex 9, France
| | - PHILIPPE CINQUIN
- Université de Grenoble/CNRS, TIMC-IMAG, Techniques de l'Ingénierie Médicale et de la Complexité, Domaine de la Merci, 38710 La Tronche, France
| |
Collapse
|
27
|
White SB, Stavropoulos SW. Management of Endoleaks following Endovascular Aneurysm Repair. Semin Intervent Radiol 2011; 26:33-8. [PMID: 21326529 DOI: 10.1055/s-0029-1208381] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Endovascular aneurysm repair (EVAR) has emerged as a viable alternative to open repair for abdominal aortic aneurysms. Endoleaks are a complication unique to EVAR and can occur in up to 25% of patients. In this article, the management of endoleaks following EVAR will be discussed.
Collapse
Affiliation(s)
- Sarah B White
- Department of Radiology, Division of Interventional Radiology, Hospital of the University of Pennsylvania, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania
| | | |
Collapse
|
28
|
ENDOCOM: Implantable wireless pressure sensor for the follow-up of abdominal aortic aneurysm stented. Ing Rech Biomed 2011. [DOI: 10.1016/j.irbm.2011.01.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
29
|
Marchiori A, von Ristow A, Guimaraes M, Schönholz C, Uflacker R. Predictive Factors for the Development of Type II Endoleaks. J Endovasc Ther 2011; 18:299-305. [DOI: 10.1583/10-3116.1] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
30
|
Tsui JC. Experimental models of abdominal aortic aneurysms. Open Cardiovasc Med J 2010; 4:221-30. [PMID: 21270944 PMCID: PMC3026392 DOI: 10.2174/1874192401004010221] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Revised: 09/27/2010] [Accepted: 10/04/2010] [Indexed: 02/04/2023] Open
Abstract
Despite being a leading cause of death in the West, the pathophysiology of abdominal aortic aneurysms (AAA) is still incompletely understood. Pharmacotherapy to reduce the growth of small AAAs is limited and techniques for repairing aneurysms continue to evolve. Experimental models play a key role in AAA research, as they allow a detailed evaluation of the pathogenesis of disease progression. This review focuses on in vivo experimental models, which have improved our understanding of the potential mechanisms of AAA development and contributed to the advancement of new treatments.
Collapse
Affiliation(s)
- Janice C Tsui
- Division of Surgery & Interventional Science, University College London, Royal Free Campus, Pond Street, London NW3 2QG, UK
| |
Collapse
|
31
|
Reporting standards for thoracic endovascular aortic repair (TEVAR). J Vasc Surg 2010; 52:1022-33, 1033.e15. [DOI: 10.1016/j.jvs.2010.07.008] [Citation(s) in RCA: 566] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2010] [Revised: 07/11/2010] [Accepted: 07/14/2010] [Indexed: 11/22/2022]
|
32
|
Chaikof EL, Brewster DC, Dalman RL, Makaroun MS, Illig KA, Sicard GA, Timaran CH, Upchurch GR, Veith FJ. The care of patients with an abdominal aortic aneurysm: the Society for Vascular Surgery practice guidelines. J Vasc Surg 2009; 50:S2-49. [PMID: 19786250 DOI: 10.1016/j.jvs.2009.07.002] [Citation(s) in RCA: 467] [Impact Index Per Article: 29.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2009] [Revised: 07/06/2009] [Accepted: 07/06/2009] [Indexed: 02/08/2023]
Affiliation(s)
- Elliot L Chaikof
- Department of Surgery, Emory University, Atlanta, Ga 30322, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Bosman WMPF, Hinnen JW, Rixen DJ, Hamming JF. Effect of Stent-Graft Compliance on Endotension After EVAR. J Endovasc Ther 2009; 16:105-13. [DOI: 10.1583/08-2505.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
34
|
Rosen RJ, Green RM. Endoleak Management following Endovascular Aneurysm Repair. J Vasc Interv Radiol 2008; 19:S37-43. [DOI: 10.1016/j.jvir.2008.01.017] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2007] [Revised: 01/15/2008] [Accepted: 01/15/2008] [Indexed: 10/22/2022] Open
|
35
|
Orra HA, Puech-Leão P, Silva ESD, Silva DG. Aneurysm pulsatility after endovascular exclusion--an experimental study using human aortic aneurysms. Clinics (Sao Paulo) 2008; 63:67-70. [PMID: 18297209 PMCID: PMC2664191 DOI: 10.1590/s1807-59322008000100012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2007] [Accepted: 09/19/2007] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To measure the pulsatility of human aneurysms before and after complete exclusion with an endograft. METHOD Five aortic aneurysms obtained during necropsy were submitted to pulsatile perfusion before and after implantation of a bifurcated endograft. The specimens were contained in a closed chamber filled with saline solution. A vertical tube attached to the chamber was used to measure volume dislocation in each systole. Mural thrombus was kept intact, and the space around the device was filled with human blood. After each experiment, the aneurysm was opened to check for the correct positioning and attachment of the device. RESULTS The level of the saline column oscillated during pulsation in each case, with respective amplitudes of 17, 16, 13, 7, and 25 cm before the endograft insertion. After the insertion, the amplitudes dropped to 13, 12, 9, 3.5, and 23 cm, respectively. The differences were not significant. During the post-experimental examination, all devices were found to be in position and well attached to the neck and iliacs. No endoleak was detected during perfusion or by visual inspection. CONCLUSION Pulsation of an endograft is transmitted to the aneurysm wall even in the absence of endoleak, and should not be interpreted as procedural failure.
Collapse
Affiliation(s)
- Hussein Amin Orra
- Cirurgia Vascular e Endovascular, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | | | | | | |
Collapse
|
36
|
Wolters BJBM, Emmer M, Rutten MCM, Schurink GWH, van de Vosse FN. Assessment of endoleak significance after endovascular repair of abdominal aortic aneurysms: A lumped parameter model. Med Eng Phys 2007; 29:1106-18. [PMID: 17197229 DOI: 10.1016/j.medengphy.2006.11.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2006] [Revised: 11/24/2006] [Accepted: 11/25/2006] [Indexed: 11/29/2022]
Abstract
The outcome of endovascular repair of abdominal aortic aneurysms (AAAs) is greatly compromised by the possible occurrence of endoleak. Previously, the causes and effects of endoleak on a patient-specific basis have mainly been investigated in experimental studies. In order to both reconcile and physically substantiate the various experimental findings, a lumped parameter model of an incompletely excluded AAA was developed. After experimental validation, the model was applied to study the effects on the intrasac pressure of the degree of endoleak, the degree of stent-graft compliance, and the resistance of a possible outflow tract formed by a branching vessel. It is concluded that the presence of endoleak leads to elevated intrasac pressure, the mean of which is mainly governed by the outflow tract resistance, while the pulse pressure is governed by both the endoleak resistance and the stent-graft compliance. Based on the agreement of the current results with previous findings, it is further concluded that the lumped parameter modelling method provides a useful numerical tool for validating experimental endoleak studies.
Collapse
Affiliation(s)
- B J B M Wolters
- Department of Biomedical Engineering, Eindhoven University of Technology, The Netherlands.
| | | | | | | | | |
Collapse
|
37
|
Hinnen JW, Koning OHJ, van Bockel JH, Hamming JF. Aneurysm Sac Pressure after EVAR: The Role of Endoleak. Eur J Vasc Endovasc Surg 2007; 34:432-41; discussion 442-3. [PMID: 17669670 DOI: 10.1016/j.ejvs.2007.05.022] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2007] [Accepted: 05/27/2007] [Indexed: 10/23/2022]
Abstract
OBJECTIVE The relation between endoleak and aneurysm sac pressure is not completely clear. This review evaluates the effect of endoleaks on aneurysm sac pressure and summarizes the present knowledge regarding aneurysm sac pressure after EVAR. METHODS A systematic search of literature was carried out using MEDLINE, EMBASE and Web of Science. Studies were included if aneurysm sac pressure measurements as well as systemic pressure measurements were performed during or after EVAR. Mean pressure indices (MPI), ratio mean aneurysm sac pressure to mean systemic pressure), in the absence of endoleaks and in the presence of different type of endoleaks were compared. RESULTS Stent-graft deployment does not seem to result in immediate reduction of aneurysm sac in the absence of an endoleak. Aneurysm sac pressure is elevated in the presence of an endoleak. However, the MPIs differ widely between studies both in the absence and presence of an endoleak. CONCLUSION MPI is not specific to the type of endoleak. This implies that the same type of endoleak does not necessarily pose the same MPI and by this the same hazard of aneurysm rupture, because the aneurysm sac pressure is directly related to the aneurysm wall stress.
Collapse
Affiliation(s)
- J W Hinnen
- Section of Vascular Surgery, Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands.
| | | | | | | |
Collapse
|
38
|
Kleinstreuer C, Li Z, Farber MA. Fluid-Structure Interaction Analyses of Stented Abdominal Aortic Aneurysms. Annu Rev Biomed Eng 2007; 9:169-204. [PMID: 17362195 DOI: 10.1146/annurev.bioeng.9.060906.151853] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Rupture of abdominal aortic aneurysms (AAAs) alone is the thirteenth leading cause of death in the United States. Thus, reliable AAA-rupture risk prediction is an important advancement. If repair becomes necessary, the minimally invasive technique of inserting a stent-graft (SG), commonly referred to as endovascular aneurysm repair (EVAR), is a viable option in many cases. However, postoperative complications, such as endoleaks and/or SG migration, may occur. Computational fluid-structure interaction simulations provide physical insight into the hemodynamics coupled with multi-wall mechanics' function as an assessment tool for optimal SG placement and improved device design.
Collapse
Affiliation(s)
- C Kleinstreuer
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27695, USA.
| | | | | |
Collapse
|
39
|
Stavropoulos SW, Charagundla SR. Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair1. Radiology 2007; 243:641-55. [PMID: 17517926 DOI: 10.1148/radiol.2433051649] [Citation(s) in RCA: 153] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Endovascular aortic aneurysm repair (EVAR) is evolving into a viable alternative to open surgical repair for many patients with abdominal and thoracic aortic aneurysms. Endoleak development is a complication of EVAR and represents one of the limitations of this procedure. Endoleaks represent blood flow outside the stent-graft lumen but within the aneurysm sac. Lifelong imaging surveillance of patients after EVAR is critical to detect endoleaks for the patient's benefit and to determine the long-term performance of the stent-graft. Although computed tomographic angiography is the most commonly used examination for imaging surveillance, magnetic resonance angiography, ultrasonography, and digital subtraction angiography all have a role in endoleak detection and management. This review will focus on imaging techniques used for endoleak detection and the role imaging surveillance plays in the overall care of the post-EVAR patient.
Collapse
Affiliation(s)
- S William Stavropoulos
- Department of Radiology, Division of Interventional Radiology, Hospital of the University of Pennsylvania, 3400 Spruce St, Philadelphia, PA 19104, USA.
| | | |
Collapse
|
40
|
Ling AJ, Pathak R, Garbowski M, Nadkarni S. Treatment of a Large Type II Endoleak via Extraperitoneal Dissection and Embolization of a Collateral Vessel Using Ethylene Vinyl Alcohol Copolymer (Onyx). J Vasc Interv Radiol 2007; 18:659-62. [PMID: 17494849 DOI: 10.1016/j.jvir.2007.02.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Type II endoleak is defined as persistent blood flow and pressure within an aneurysmal sac after endovascular deployment of a stent graft from patent aortic branches. This paper describes the simultaneous deployment of an endoluminal graft, with limited extraperitoneal dissection of a collateral vessel and use of an ethylene vinyl alcohol copolymer, Onyx, to obliterate a large type II endoleak.
Collapse
Affiliation(s)
- Adrian J Ling
- Department of Vascular Surgery, Sir Charles Gairdner Hospital, Western Australia 6008, Australia.
| | | | | | | |
Collapse
|
41
|
Eagleton MJ, Srivastava SD, Upchurch GR. Endovascular Grafts. Vasc Med 2006. [DOI: 10.1016/b978-0-7216-0284-4.50046-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
42
|
Hong KC, Kim JY, Jeon YS. Endovascular Aneurysm Repair. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2006. [DOI: 10.5124/jkma.2006.49.6.542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Kee Chun Hong
- Department of Surgery, Inha University College of Medicine & Hospital, Korea.
| | - Jang Yong Kim
- Department of Surgery, Inha University College of Medicine & Hospital, Korea.
| | - Yong Sun Jeon
- Department of Radiology, Inha University College of Medicine & Hospital, Korea
| |
Collapse
|
43
|
Rhee JY, Trocciola SM, Dayal R, Lin S, Chaer R, Kumar N, Mousa A, Bernheim J, Christos P, Prince M, Marin ML, Gordon R, Badimon J, Fuster V, Kent KC, Faries PL. Treatment of type II endoleaks with a novel polyurethane thrombogenic foam: induction of endoleak thrombosis and elimination of intra-aneurysmal pressure in the canine model. J Vasc Surg 2005; 42:321-328. [PMID: 16102634 DOI: 10.1016/j.jvs.2005.04.043] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2005] [Accepted: 04/16/2005] [Indexed: 11/17/2022]
Abstract
OBJECTIVE The clinical significance and treatment of retrograde collateral arterial perfusion of abdominal aortic aneurysms after endovascular repair (type II endoleak) have not been completely characterized. A canine abdominal aortic aneurysm model of type II endoleak with an implanted pressure transducer was used to evaluate the use of polyurethane foam to induce thrombosis of type II endoleaks. The effect on endoleak patency, intra-aneurysmal pressure, and thrombus histology was studied. METHODS Prosthetic aneurysms with an intraluminal, solid-state, strain-gauge pressure transducer were created in the infrarenal aorta of 14 mongrel dogs. Aneurysm side-branch vessels were reimplanted into the prosthetic aneurysm of 10 animals by using a Carrel patch. Type II (retrograde) endoleaks were created by excluding the aneurysm from antegrade perfusion with an impermeable stent graft. Thrombosis of the type II endoleak was induced by implantation of polyurethane foam into the prosthetic aneurysm sac of four animals. Six animals with type II endoleaks were not treated. In four control animals, no collateral side branches were reimplanted, and therefore no endoleak was created. Intra-aneurysmal and systemic pressures were measured daily for 60 to 90 days after the implantation of the stent graft. Endoleak patency and flow were assessed during surgery and at the time of death by using angiographic imaging and duplex ultrasonography. Histologic analysis of the intra-aneurysmal thrombus was also performed. RESULTS Intra-aneurysmal pressure values are indexed to systemic pressure and are represented as a percentage of the simultaneously obtained systemic pressure, which has a value of 1.0. All six animals with untreated type II endoleaks maintained patency of the endoleak and side-branch arteries throughout the study period. Compared with control aneurysms that had no endoleak, animals with patent type II endoleaks exhibited significantly higher intra-aneurysmal pressurization (systolic pressure: patent type II endoleak, 0.702 +/- 0.283; control, 0.172 +/- 0.091; P < .001; mean pressure: endoleak, 0.784 +/- 0.229; control, 0.137 +/- 0.102; P < .001; pulse pressure: endoleak, 0.406 +/- 0.248; control, 0.098 +/- 0.077; P < .001; P < .001 for comparison for all groups by analysis of variance). Treatment of the type II endoleak with polyurethane foam induced thrombosis of the endoleak and feeding side-branch arteries in all four animals with type II endoleaks. This resulted in intra-aneurysmal pressures statistically indistinguishable from the controls (systolic pressure, 0.183 +/- 0.08; mean pressure, 0.142 +/- 0.09; pulse pressure, 0.054 +/- 0.04; not significant). Angiography and histology documented persistent patency up to the time of death (mean, 64 days) for untreated type II endoleaks and confirmed thrombosis of polyurethane foam-treated endoleaks in all cases. CONCLUSIONS Untreated type II endoleaks were associated with intra-aneurysmal pressures that were 70% to 80% of systemic pressure. Treatment with polyurethane foam resulted in a reduction of intra-aneurysmal pressure to a level that was indistinguishable from control aneurysms that had no endoleak. CLINICAL RELEVANCE Endovascular repair of abdominal aortic aneurysms is dependent on the successful exclusion of the aneurysm from arterial circulation. Type II endoleaks originate from retrograde flow into the aneurysm sac. This study demonstrates the use of polyurethane foam to induce thrombosis in a canine model of a type II endoleak, thereby reducing intra-aneurysmal pressure to levels similar to levels in animals without endoleaks. This approach may be a strategy for future treatment of type II endoleaks.
Collapse
Affiliation(s)
- Jason Y Rhee
- Department of Surgery, New York Presbyterian Hospital, Cornell University, Weill Medical College, Columbia University, College of Physicians and Surgeons, NY 10021, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
44
|
Hinnen JW, Visser MJT, van Bockel JH. Aneurysm Sac Pressure Monitoring: Effect of Technique on Interpretation of Measurements. Eur J Vasc Endovasc Surg 2005; 29:233-8. [PMID: 15694793 DOI: 10.1016/j.ejvs.2004.11.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/30/2004] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The purpose of this study is to determine the accuracy of measuring pressure with a fluid filled pressure device (needle) and a non-fluid filled pressure device (catheter) inside a thrombosed aneurysmal sac after exclusion from circulation by endovascular grafting. METHODS In a static environment, consisting of a syringe to which a pressure monitoring kit was connected, experiments were performed to study the influence of the type of device (either needle or catheter) and the effect of the characteristics of the medium on the accuracy and reproducibility of pressure measurements. The pressures obtained with the needle in the different kinds of media were compared with those obtained in blood. Similar experiments were performed using a pressure catheter. Subsequently, pressure measurements were performed in a dynamic and physiological environment. This environment consisted of an artificial circulation in which an aneurysm, constructed of porcine aorta and filled with human aortic thrombus, was mounted. The pressures were compared and analyzed by Bland-Altman plots. RESULTS Under static conditions, the pressure levels obtained by a needle in blood, starch solution and thrombus were similar. Under identical conditions, pressures obtained by a catheter in starch solution were significant lower than the pressures measured in blood (P<0.05). Under dynamic pressure conditions the reproducibility of pressures obtained with the needle inserted in the human thrombus was very poor. CONCLUSION A needle pressure measuring device, inserted into media like human fibrin thrombus, does not yield accurate and reproducible results. A catheter with a tip-sensor rather than a needle is superior to study the pressure in the aneurysm sac after EVAR.
Collapse
Affiliation(s)
- J W Hinnen
- Section of Vascular Surgery, Department of Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | | | | |
Collapse
|
45
|
Biebl M, Hakaim AG, Oldenburg WA, Klocker J, Lau LL, Neuhauser B, McKinney JM, Paz-Fumagalli R. Does Chronic Oral Anticoagulation With Warfarin Affect Durability of Endovascular Aortic Aneurysm Exclusion in a Midterm Follow-up? J Endovasc Ther 2005; 12:58-65. [PMID: 15683272 DOI: 10.1583/04-1337r.1] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To evaluate the effect of oral anticoagulation on durability of endovascular aortic aneurysm repair (EVAR). METHODS Retrospective review was conducted of 182 consecutive EVAR patients (169 men; mean age 75.3 years, range 53-89) between 1999 and 2003. Patients on warfarin anticoagulation (WA, n=21; International Normalized Ratio of 2 to 3) were compared against a control group (CG) with no postoperative anticoagulation (n=161). Death, aneurysm rupture, and reintervention were considered primary endpoints; endoleaks, endograft migration, and aneurysm remodeling were secondary endpoints. RESULTS Mean follow-up was 16.3+/-12.6 months. One-year mortality was 6.6% (9.5% WA versus 6.2% CG); overall mortality was 14.3% (p=0.414). No aneurysm rupture occurred. At 1, 2, and 3 years, respectively, cumulative reinterventions (20%/20%/20% WA versus 12%/15%/20% CG; p=0.633) and endoleak rates (25%/25%/25% WA versus 17%/22%/34% CG; p=0.649) were comparable. In both groups, most completion endoleaks resolved (42.9% WA versus 74.4% CG; p=0.474), but few de novo endoleaks did (0% WA versus 12.8% CG; p=0.538). Anticoagulation did not affect mean time to aneurysm sac shrinkage (1.3+/-0.3 WA versus 1.4+/-0.1 years CG; p=0.769). CONCLUSIONS After EVAR, anticoagulation appears safe and does not significantly alter mortality, risk for rupture, or the incidence of reintervention. Early endoleaks appear more common in anticoagulated patients, but anticoagulation does not preclude spontaneous endoleak resolution nor does it increase late endoleak rates. Irrespective of the anticoagulation status, early but not late endoleaks usually sealed spontaneously. Observing type II endoleaks appears safe in the absence of aneurysm enlargement.
Collapse
Affiliation(s)
- Matthias Biebl
- Section of Vascular Surgery, Mayo Clinic Jacksonville, Florida 32224, USA
| | | | | | | | | | | | | | | |
Collapse
|
46
|
van Sambeek MRHM, Hendriks JM, Tseng L, van Dijk LC, van Urk H. Sac enlargement without endoleak: When and how to convert and technical considerations. Semin Vasc Surg 2004; 17:284-7. [PMID: 15614752 DOI: 10.1053/j.semvascsurg.2004.09.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The primary goal of endovascular treatment of abdominal aortic aneurysms (AAA) is prevention of death from rupture. Even in the absence of an endoleak, the AAA may continue to enlarge. The pathogenesis of this phenomenon remains unclear. Therefore, surveillance after endovascular AAA treatment must include regular evaluation of aneurysm size, or even better, aneurysm volume. Aneurysm sac enlargement without an endoleak is not a benign condition. Recurrent or persistent pressurization of the AAA sac will eventually result in rupture. Besides that, continued expansion of the AAA sac can result in dilatation of the infrarenal neck and/or iliac arteries, which may threaten the integrity of proximal and distal anastomotic seals. Many centers will take a pragmatic approach in case of endotension and a growing AAA, and convert to open surgery with removal of the endograft and placement of a regular vascular graft. Direct puncture and pharmacological intervention in the cause of sac enlargement by local instillation seems logical, but has failed so far. The third option for aneurysm sac enlargement without an endoleak is laparoscopic or open fenestration of the aneurysm. Until permanent solutions for endotension and endoleaks are found, endovascular aneurysm repair will remain an imperfect long-term treatment and continued follow-up will be mandatory.
Collapse
Affiliation(s)
- Marc R H M van Sambeek
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
47
|
Chaudhuri A, Ansdell LE, Grass AJ, Adiseshiah M. Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: an experimental study. Eur J Vasc Endovasc Surg 2004; 28:373-8. [PMID: 15350558 DOI: 10.1016/j.ejvs.2004.07.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
PURPOSE To ascertain the nature of the pressure wave transmitted through aneurysm thrombus and the changes produced after endovascular repair and the development of type I and II endoleaks. METHODS A 25 mm Talent endovascular graft was deployed in a latex model of an abdominal aortic aneurysm, which was incorporated in a pulsatile flow unit. The graft was surrounded by thrombus analogue to simulate conditions in vivo. Pressure waveforms in the sac were captured over 5s at 1000 Hz in these settings: (i) no endoleaks (baseline), after introduction of (ii) type I (iii) type II and (iv) combined type I and II endoleaks. The arterial blood pressure settings used were 140/100 and 130/90 mmHg, denoted the high and low settings, respectively. ANOVA in Minitab 13 was applied for statistical analysis. RESULTS Pulsatile waveforms were transmitted through the thrombus. Intrasac pressure after stent-grafting reduced to 110/107, 99/96 mmHg (p<0.001) (high, low settings, respectively). Introduction of a type I endoleak caused this to rise to 120/112, 115/107 mmHg (p<0.001, vs. baseline); after producing a type II endoleak these were 101/98, 91/88 mmHg (p<0.001, vs. baseline). A combined type I and II endoleak produced intrasac pressures identical to that of a type I endoleak. CONCLUSIONS Intrasac pressure waveforms following EVAR are easily defined following a type I endoleak. Waveforms obtained following type II endoleak simulation resemble the baseline waveform in an attenuated form. Intrasac pressures are, therefore, a reliable marker for type I, but not a type II endoleak. In the case of a combined endoleak, the type I endoleak waveform effectively masks that of the type II. Intrasac thrombus faithfully transmits intrasac pressures.
Collapse
Affiliation(s)
- A Chaudhuri
- Vascular/Endovascular Unit, University College London Hospital, W1G 6DE London, UK
| | | | | | | |
Collapse
|
48
|
Dayal R, Mousa A, Bernheim J, Hollenbeck S, Henderson P, Prince M, Gordon R, Badimon J, Fuster V, Marin ML, Kent KC, Faries PL. Characterization of retrograde collateral (type II) endoleak using a new canine model. J Vasc Surg 2004; 40:985-994. [PMID: 15557915 DOI: 10.1016/j.jvs.2004.07.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The clinical significance of retrograde collateral arterial perfusion of abdominal aortic aneurysms after endovascular repair (type II endoleak) has not been completely characterized. In this study a canine model was used to analyze intra-aneurysmal pressure, thrombus histologic characteristics, endoleak patency, and radiographic appearance of type II endoleaks originating from single and multiple aneurysm side branches. METHODS Prosthetic aneurysms with an intraluminal solid-state strain-gauge pressure transducer were created in the infrarenal aorta of 14 mongrel dogs. A single collateral side branch was reimplanted in 4 animals, multiple side branches were reimplanted in 6 animals, and no side branches were reimplanted in 4 control animals. Intra-aneurysmal and systemic pressure was measured for 60 to 90 days after creation of the type II endoleak. Endoleak patency and flow were assessed with duplex ultrasound scanning and cine-magnetic resonance angiography. Histologic analysis of the intra-aneurysmal thrombus was also performed. RESULTS Stent-graft exclusion reduced intra-aneurysmal pressure significantly in all animals, as compared with systemic pressure (P < .001). All intra-aneurysmal pressure values are indexed to the systemic pressure, and are represented as a percentage of the simultaneously obtained systemic pressure, which has a value of 1.0. Type II endoleaks originating from multiple side branches exhibited significantly increased intra-aneurysmal systolic pressure, mean pressure, and pulse pressure, as compared with endoleaks derived from either a single side branch (systolic pressure: multiple, 0.70 +/- 0.28 vs single, 0.50 +/- 0.19; P < .001; mean pressure: multiple, 0.78 +/- 0.23 vs single, 0.59 +/- 0.22, P < .001; pulse pressure: multiple, 0.41 +/- 0.25 vs single, 0.17 +/- 0.15, P < .001) or excluded control aneurysms that had no side branches and no endoleak (systolic pressure, 0.17 +/- 0.09; mean pressure, 0.14 +/- 0.10; pulse pressure, 0.098 +/- 0.08; P < .001). Cine-magnetic resonance angiograms and duplex ultrasound scans documented persistent patency of multiple branch endoleaks up to the time of euthanasia. In contrast, single side branch endoleaks thrombosed within 3 days (P < .001). Thrombus in the aneurysm sac in close proximity to the endoleak contained intact red blood cells and limited fibrin. Thrombus distant from the endoleak demonstrated extensive fibrin deposition and degraded red blood cells. CONCLUSION The canine model may be used to reliably measure intra-aneurysmal pressure in the presence of patent and thrombosed type II endoleaks. In this model 2 or more side branches are necessary to maintain persistent patency of type II endoleaks. These endoleaks are associated with significantly elevated intra-aneurysmal pressure, that is, 70% to 80% of systemic pressure. These results suggest that persistent type II endoleaks have clinical significance. CLINICAL RELEVANCE Endoleaks originating from retrograde flow in the side branch vessels of the aneurysm generate significant levels of intra-aneurysmal pressure, that is, 70% to 80% of systemic pressure. At least 2 patent side branch vessels appear to be necessary to cause persistent patency of type II endoleak in the canine model. Further studies will be necessary to enable more complete characterization of retrograde endoleaks and to extend these findings to allow clinical application. However, these results suggest that persistently patent type II endoleaks are clinical significance and may require more intensive follow-up intervention.
Collapse
Affiliation(s)
- Rajeev Dayal
- Department of Surgery, Cornell University, New York, NY 10021, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Ayuso JR, de Caralt TM, Pages M, Riambau V, Ayuso C, Sanchez M, Real MI, Montaña X. MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses. J Magn Reson Imaging 2004; 20:803-10. [PMID: 15503334 DOI: 10.1002/jmri.20170] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To evaluate whether MR angiography (MRA) is a useful tool for the follow-up of aortic aneurysms treated with nitinol endoluminal grafts. MATERIALS AND METHODS We examined 28 patients treated with nitinol endovascular stents to repair an aortic aneurysm with CT angiography (CTA) and MRA. Eleven patients (group 1) underwent an MRA after a positive CTA for endoleak was observed. Afterwards, 17 patients (group 2) were scheduled for both follow-up examinations. The kind of endoleak that occurred and the maximum aortic diameter were compared. The sensitivity of CTA relative to MRA for detecting endoleaks in group 2 was calculated. Signal-to-noise ratios (SNRs) were measured in the aortoiliac lumen at the arterial phase in, above, and below the endoprostheses. Student's t-test was used to compare aneurysm dimensions and SNR measurements. RESULTS Three type III leaks were correctly assessed at both examinations; however, CTA was less sensitive (50%) than MRA in depicting type II or unclassified leaks. No differences in aneurismal size were observed between the two examinations or between arterial SNRs observed in or out of the devices. CONCLUSION MRA can provide all relevant information necessary for the follow-up of patients treated with nitinol endoprostheses, and performs better than CTA in detecting endoleaks.
Collapse
Affiliation(s)
- Juan R Ayuso
- Centre de Diagnostic per la Imatge Clinic, Hospital Clinic, Barcelona, Spain.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Dias NV, Ivancev K, Malina M, Hinnen JW, Visser M, Lindblad B, Sonesson B. Direct intra-aneurysm sac pressure measurement using tip-pressure sensors: In vivo and in vitro evaluation. J Vasc Surg 2004; 40:711-6. [PMID: 15472599 DOI: 10.1016/j.jvs.2004.07.045] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Direct intra-aneurysm sac pressure measurement with percutaneous translumbar puncture is a new method for follow-up after endovascular aneurysm repair. The purpose of this study was to evaluate a tip-pressure sensor system for intra-aneurysm pressure measurement in an in vitro aneurysm model and in vivo in patients by studying intraobserver variability. METHODS We used 0.014-inch guide wire-mounted tip-pressure sensors. For the in vitro aneurysm model, saccular aneurysms filled with thrombus were inserted in a left-heart-driven aneurysm model. Pressure was measured simultaneously with guide wire pressure sensors in the lumen of the model and within the aneurysm thrombus. In vivo, intraobserver variability was evaluated with double percutaneous translumbar puncture of the abdominal aortic aneurysm (AAA) with pressure measurement in 15 patients (14 men, 1 woman; median age, 75 years [63-80 years]; median AAA diameter, 55 mm [47-80 mm]) at a median of 32 months (2-100 months) after endovascular aneurysm repair. Mean pressure index was calculated as the percentage of mean intraaneurysm pressure relative to simultaneous mean systemic pressure. RESULTS In vitro, the difference in pressure between the tip-sensor measurements and the pressure output of the aneurysm model was 2 mm Hg (1-4 mm Hg) when the output varied between 150/50 and 200/100 mm Hg (n = 90). Mean pressure in the lumen of the model and within the aneurysm thrombus differed by 1 mm Hg (-5-15 mm Hg (n = 10). In vivo, intraobserver variability of mean pressure index (Bland-Altman plot) was 0% (-7%-17%; n = 15%). CONCLUSION Direct intra-aneurysm sac pressure measurement with tip-pressure sensors mounted on 0.014-inch guide wires is a reliable and reproducible technique for measuring intra-AAA pressure both in vitro and in vivo.
Collapse
Affiliation(s)
- Nuno V Dias
- Endovascular Center, Department of Radiology, Malmö University Hospital, Sweden.
| | | | | | | | | | | | | |
Collapse
|