1
|
Sara M, Hui A, Yasir M, Peguda HK, Kalaiselvan P, Willcox M. Intrastromal Corneal Ring Implants Associated Bacterial Infections. Curr Eye Res 2024:1-9. [PMID: 38780797 DOI: 10.1080/02713683.2024.2354438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 05/07/2024] [Indexed: 05/25/2024]
Abstract
PURPOSE This study examines the incidence of infection and resistance associated with Intracorneal Ring Segment (ICRS) implantation, a common outpatient surgical treatment for correcting refractive errors and corneal ectatic diseases. Although ICRS procedures are typically safe and reversible, there is a low but notable risk of microbial infections, which require prompt and sometimes invasive treatment. METHODS Three electronic databases, PubMed, Web of Science (WoS), and Scopus, were utilised to search for literature according to PRISMA guidelines to identify infections related to the implantation of ICRS in the cornea between January 2000 and December 2022. RESULTS Gram-positive organisms were involved in 86% of cases: 35.7% S. aureus, 25% coagulase-negative staphylococci species, 17.8% streptococci and 7.1% Nocardia species. Less commonly recorded were Gram-negative bacteria (14%), with Pseudomonas aeruginosa (circa 10%) and Klebsiella pneumonia (4%) being the most common Gram-negative bacteria. In rare cases, fungi have also been reported. ICRS-related bacterial infections can be categorised into early or late onset. Early onset infection typically manifests within the first few weeks after implantation and is often associated with contamination during surgery, unhygienic practices, or inadequate sterilisation techniques. On the other hand, late-onset infection may develop months or even years after the initial procedures and may be associated with persistent bacterial colonisation, secondary infections, or prolonged use of prophylactic antibiotics. S aureus is encountered in both early and late-onset infections, while Nocardia species and K. pneumoniae have generally been reported to occur in late-onset infections. In addition, vision recovery from S. aureus infections tends to be poor compared to other bacterial infections. CONCLUSION S. aureus is a predominant pathogen that often requires surgical intervention with poor outcomes. Early infections result from incision gaps and ring segment rubbing, while late infections are linked to prolonged antibiotic use. Further research is needed on novel antimicrobial ICRS to procure the vision.
Collapse
Affiliation(s)
- Manjulatha Sara
- School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia
| | - Alex Hui
- School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia
- Centre for Ocular Research and Education, University of Waterloo, Waterloo, Ontario, Canada
| | - Muhammad Yasir
- School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia
| | - Hari Kumar Peguda
- School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
2
|
Nacaroglu SA, Yesilkaya EC, Perk FFNK, Tanriverdi C, Taneri S, Kilic A. Efficacy and safety of intracorneal allogenic ring segment implantation in keratoconus: 1-year results. Eye (Lond) 2023; 37:3807-3812. [PMID: 37328510 PMCID: PMC10698022 DOI: 10.1038/s41433-023-02618-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 05/15/2023] [Accepted: 06/02/2023] [Indexed: 06/18/2023] Open
Abstract
BACKGROUND To evaluate the safety and efficacy of corneal allogenic intrastromal ring segments in the management of keratoconus patients. METHODS The retrospective, nonrandomized, interventional case series consisted of 65 keratoconic eyes of 49 consecutive patients who had ring segment-shaped corneal allografts (KeraNatural®) implanted in intrastromal tunnels created using a femtosecond laser. The main outcome measures were uncorrected visual acuity (UCVA), corrected distant visual acuity (CDVA), refraction, keratometry, and pachymetry. Computed tomography scans of the corneal surfaces were also performed preoperatively as well as 3, 6 and 12 months postoperatively. RESULTS Mean age was 29.5 ± 7.3 years (median 29, range: 20-52 years). The mean UCVA improved from 0.91 ± 0.50 logMAR preoperatively to 0.40 ± 0.24 logMAR postoperatively at 6 month follow-up (p < 0.01) and the mean CDVA improved from 0.87 ± 0.20 logMAR preoperatively to 0.27 ± 0.06 logMAR postoperatively (p < 0.01). The mean spherical equivalent improved from -8.82 ± 4.57 to -3.45 ± 4.81D (p < 0.01). Average Keratometry decreased from 49.23 ± 5.22 preoperatively to 45.63 ± 4.89 D postoperatively (p < 0.01). Mean anterior and posterior maximum elevation were also decreased significantly (p < 0.01). In one patient, dislocation of the graft towards the tunnel incision site and dehiscense at the tunnel entrance were observed in the first week of the operation. Yellow-white deposits were observed in the segment tunnels in five cases after 6 months. CONCLUSION This study demonstrated that implantation of corneal allograft ring segments is a viable alternative treatment for keratoconus with safety and good visual results.
Collapse
Affiliation(s)
- Senay Asik Nacaroglu
- Faculty of Medicine, Ophthalmology Department, Istanbul Medipol University, Istanbul, Turkey.
| | - Elif Ceren Yesilkaya
- Şişli Hamidiye Etfal Training and Research Hospital, Department of Ophthalmology, University of Health Sciences, Istanbul, Turkey
| | | | - Cafer Tanriverdi
- Faculty of Medicine, Ophthalmology Department, Istanbul Medipol University, Istanbul, Turkey
| | - Suphi Taneri
- Ophthalmology Department, Augenzentrum am St. Franziskus Hospital, Munster, Germany
| | - Aylin Kilic
- Faculty of Medicine, Ophthalmology Department, Istanbul Medipol University, Istanbul, Turkey
| |
Collapse
|
3
|
Rajabi S, Asharlous A, Riazi A, Khabazkhoob M, Moalej A. Differences and Limits of Agreement among Pentacam, Corvis-ST, and IOL-Master 700 Optical Biometric Devices regarding Central Corneal Thickness Measurements. J Curr Ophthalmol 2022; 34:44-49. [PMID: 35620377 PMCID: PMC9128434 DOI: 10.4103/joco.joco_96_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 07/07/2021] [Accepted: 07/09/2021] [Indexed: 11/24/2022] Open
Abstract
Purpose: To investigate the differences and limits of agreement in measuring corneal thickness using Pentacam, Corvis, and intraocular lens (IOL)-Master 700 devices. Methods: This study was conducted on 37 right eyes of 21 males and 16 females (n = 37) with a mean age of 52.11 ± 6.30 years. The central corneal thickness was measured using three optical biometric devices, including Pentacam, Corvis, and IOL-Master 700. The inclusion criteria were normal eyes without any ophthalmological abnormalities, history of ocular pathology, or ocular surgery. The data obtained from these three devices were compared two by two. The correlation and agreement limits among them were analyzed using statistical techniques. Results: The mean standard deviation differences between Pentacam and Corvis, Pentacam and IOL-Master 700, as well as Corvis and IOL-Master 700 regarding the corneal thickness measurement, were 22.13 ± 8.05, 7.91 ± 8.02, and 14.21 ± 9.85 μm, respectively, which were statistically significant (P < 0.0001). Based on the investigation of the limits of agreement according to the Bland Altman method, the corresponding values between Pentacam and Corvis, Pentacam and IOL-Master 700, and Corvis and IOL-Master 700 were -16.2 to +15.4, -15.8 to +16.3, and -20.1 to +20.0 μm, respectively. Furthermore, the correlation coefficients of the measurements obtained by Pentacam and Corvis, Pentacam and IOL-Master 700, as well as Corvis and IOL-Master 700 were determined 0.957, 0.964, and 0.948, respectively (P < 0.0001). Conclusion: The results from this study indicate that the interchangeable use of these three devices is not appropriate due to statistically significant differences and broad limits of agreement among the three devices, especially between Corvis and IOL-Master 700.
Collapse
Affiliation(s)
- Sattar Rajabi
- Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
| | - Amir Asharlous
- Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran
| | - Abbas Riazi
- Department of Optometry, Iran University of Medical Sciences, Tehran, Iran
| | - Mehdi Khabazkhoob
- Department of Basic Sciences, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Alireza Moalej
- Internal Medical Clinic, Bank Melli Hospital, Tehran, Iran
| |
Collapse
|
4
|
Jafarinasab M, Hadi Y. Femtosecond laser-assisted peripheral additive stromal keratoplasty for treatment of primary corneal ectasia: Preliminary outcomes. Indian J Ophthalmol 2021; 69:2663-2668. [PMID: 34571610 PMCID: PMC8597526 DOI: 10.4103/ijo.ijo_3206_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Purpose: To report the preliminary results of a new surgical modality for the treatment of primary corneal ectasia, which consists of implanting allogeneic corneal tissue into the peripheral corneal stroma using a femtosecond laser system or femtosecond laser-assisted peripheral allogeneic stromal additive keratoplasty or FA-PASAK. Methods: This prospective, noncomparative case series includes patients with primary corneal ectasia including keratoconus and pellucid marginal degeneration. In the operating room, one or two ring or crescent-shaped allogeneic corneal segments were prepared using a handmade double-bladed punch, which were then implanted by a specially designed device, into stromal channels in the peripheral recipient cornea fashioned with a femtosecond-laser system. Results: A total of 15 eyes of 13 patients with mean age of 31.73 years were operated. There were significant improvements in uncorrected (0.68 to 0.3 logMAR) and corrected (0.44 to 0.16 logMAR) visual acuity, mean sphere, mean spherical equivalent refractive error, and mean keratometry (steep, flat, and average). Topographic and refractive astigmatism did not change significantly. Complications included a single case of bacterial keratitis secondary to epithelial defect, which was controlled with topical antibiotics eventually leading to an uncorrected vision of 20/25 one year after surgery. Conclusion: The use of allogeneic corneal ring or crescent shape segments may be a safe and cost-effective treatment for primary corneal ectasia, whereas a nomogram is necessary to be devised for general use of the technique.
Collapse
Affiliation(s)
- Mohammadreza Jafarinasab
- Eye Research Center, Shahid Labbafi Nejad Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Yasaman Hadi
- Eye Research Center, Five Senses Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
5
|
Narang P, Holladay J, Agarwal A, Gracy H, Kumar DA, Sivagnanam S. Pinhole Pupilloplasty for Higher Order Aberrations: Assessment of Visual Quality and Depth of Focus. J Refract Surg 2021; 36:812-819. [PMID: 33295993 DOI: 10.3928/1081597x-20201008-01] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 09/10/2020] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate visual quality and depth of focus under photopic and mesopic light conditions of patients treated with pinhole pupilloplasty (PPP) for corneal higher order aberrations. METHODS This was a prospective, noncomparative, interventional series and PPP was performed with a single-pass four-throw procedure in 14 eyes of 14 patients. After PPP, patients were analyzed with the Clinical Trial Suite machine (M & S Technologies, Inc) that offers a standardized method of recording visual quality. The luminance levels of 85 and 3 cd/m2 were set for photopic and mesopic lighting conditions, respectively, and uncorrected and corrected distance visual acuity were recorded for distance (4 m), intermediate (66 cm), and near (44 cm). Low contrast acuity (LCA) at 10% and mesopic contrast sensitivity function (CSF) with glare on and off at four spatial frequencies of 1.5, 3, 6, and 12 cycles per degree (cpd) and defocus curve were assessed. RESULTS Under photopic and mesopic conditions, a significant difference was observed postoperatively in uncorrected and corrected distance visual acuity for distance, intermediate, and near. The defocus curve demonstrated extended depth of focus that ranged from +1.50 to -2.50 diopters and LCA at 10% demonstrated significant improvement for all cases. For mesopic CSF, a significant improvement was noted at spatial frequencies of 3 and 6 cpd with glare on. With glare off, an improvement was seen at spatial frequencies of 1.5, 3, and 6 cpd, but not at 12 cpd. CONCLUSIONS Early results demonstrate that PPP provides improved visual quality and extended depth of focus and can be a useful option in cases with higher order aberrations. [J Refract Surg. 2020;36(12):812-819.].
Collapse
|
6
|
Naderi M, Karimi F, Jadidi K, Mosavi SA, Ghobadi M, Tireh H, Khorrami-Nejad M. Long-term results of MyoRing implantation in patients with keratoconus. Clin Exp Optom 2021; 104:499-504. [PMID: 33689613 DOI: 10.1080/08164622.2021.1878813] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
Clinical relevance: This study was conducted to evaluate five-year outcomes of MyoRing implantation in patients with keratoconus. The results showed that MyoRing implantation is a minimally invasive procedure and is safe and effective for improving visual acuity and refraction in most patients with keratoconus.Background: The long-term effects of MyoRing implantation on corneal features were studied.Methods: A total of 48 keratoconic eyes of 43 consecutive patients who had undergone MyoRing implantation using the Pocket Maker microkeratome (Dioptex, gmbh, Linz, Austria) and who had completed five years of follow‑ups were included in this retrospective study. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction and keratometry (K) readings were measured and assessed pre-operation, and five years post-operatively. As well, post-operation satisfaction was assessed using a validated questionnaire.Results: Five years post-operatively, there was a significant improvement in UDVA, CDVA, K readings, spherical equivalent (SE), and manifest sphere and cylinder (p < 0.001). Mean UDVA was 1.20 logMAR before the surgery and 0.42 after the surgery (p < 0.001). Mean CDVA was 0.63 logMAR before the surgery and 0.20 logMAR after the surgery (p < 0.001). SE was improved from -6.53 dioptres (D) before the surgery to -2.23 D after the surgery (p < 0.001). Moreover, the results show that the mean K was reduced by 2.82 D after the surgery (p = 0.001). Overall, 81% of patients were moderately to highly satisfied five years after surgery.Conclusion: MyoRing implantation was found to be a minimally invasive procedure, and is safe and effective for improving visual acuity and refraction in most patients with keratoconus.
Collapse
Affiliation(s)
- Mostafa Naderi
- Department of Ophthalmology, Bina Eye Hospital Research Center, Tehran, Iran
| | - Farshid Karimi
- Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Khosrow Jadidi
- Department of Ophthalmology, Bina Eye Hospital Research Center, Tehran, Iran
| | | | - Mohadeseh Ghobadi
- Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hossein Tireh
- Department of Epidemiology and Biostatistics, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Masoud Khorrami-Nejad
- Translational Ophthalmology Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
7
|
D'Oria F, Abdelghany AA, Ledo N, Barraquer RI, Alio JL. Incidence and Reasons for Intrastromal Corneal Ring Segment Explantation. Am J Ophthalmol 2021; 222:351-358. [PMID: 33011155 DOI: 10.1016/j.ajo.2020.09.041] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/22/2020] [Accepted: 09/23/2020] [Indexed: 12/28/2022]
Abstract
PURPOSE To determine the main causes of intrastromal corneal ring segment (ICRS) explantation and define the incidence rate. DESIGN Multicenter, observational consecutive case series. METHODS Consecutive cases of ICRSs explanted in the last 10 years were reviewed. Clinical data included age of the patients at explantation, reasons for implantation and explantation, date of implantation and explantation, tunnel creation technique, and ICRS type. Main outcomes measures were the reasons for ICRS removal and the incidence rate. RESULTS During the study period, 121 ICRSs (119 patients) were explanted, with an explantation rate of 5.60%. Functional failure (74 eyes, 61.16%) represents the main cause for ICRS removal: of them, 48 (39.67%) ICRSs were removed for refractive failure and 26 (21.49%) in the setting of a keratoplasty related to poor visual performance of the implanted eye. In addition, 47 eyes (38.84%) had ICRS removal for anatomic failure: among them, 36 (29.75%) were explanted for spontaneous extrusion (overall extrusion rate: 1.58%), 7 (5.79%) for suspected infectious keratitis, 3 (2.48%) for corneal melting, and 1 (0.83%) for corneal perforation. Mild cases of keratoconus were more prone to be explanted because of a loss of the initial improved visual acuity, whereas spontaneous extrusion happened often in advanced cases of keratoconus. CONCLUSIONS We report the largest series of ICRS explantation as of this writing. The main cause of explantation was functional refractive failure followed by spontaneous extrusion of the ICRS, that is, correlated to an anatomic failure at the site of implantation in an advanced disease.
Collapse
Affiliation(s)
- Francesco D'Oria
- Vissum Innovation, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain; Section of Ophthalmology, Department of Basic Medical Science, Neuroscience and Sense Organs, University of Bari, Bari, Italy
| | - Ahmed A Abdelghany
- Vissum Innovation, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain; Ophthalmology department, Faculty of Medicine, Minia University, Minia, Egypt
| | - Natalia Ledo
- Instituto Universitario Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Rafael I Barraquer
- Instituto Universitario Barraquer, Universitat Autònoma de Barcelona, Barcelona, Spain
| | - Jorge L Alio
- Vissum Innovation, Alicante, Spain; Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain.
| |
Collapse
|
8
|
Warrak EL, Serhan HA, Ayash JG, Wahab CH, Baban TA, Daoud RC, Sammouh FK. Long-term follow up of intracorneal ring segment implantation in 932 keratoconus eyes. J Fr Ophtalmol 2020; 43:1020-1024. [PMID: 33127181 DOI: 10.1016/j.jfo.2020.03.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/24/2020] [Accepted: 03/11/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE To evaluate the progression of keratoconus in 932 eyes of 659 patients through visual, refractive and topographic data after intracorneal ring segment (ICRS) implantation. METHODS Retrospective review of 659 patients who underwent ICRS (Intacs®) implantation for keratoconus between September 1997 and November 2017. Demographics, preoperative and postoperative uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA) in LogMAR, corneal topography parameters (thinnest pachymetry, Kmax), central corneal pachymetry and total follow-up time were evaluated. Statistical analysis was performed using IBM SPSS Statistics 24.0 for windows. RESULTS Nine hundred and thirty-two eyes of 659 patients, with a mean age of 30.41 years (range 11-76 years), were evaluated. Mean total follow up time was 3.02 years. Forty-one eyes had a total follow up of over 10 years. Both UCVA and BCVA improved significantly after ICRS implantation (P<0.01). Only 18 eyes (2.66% of eyes of patients under 35 years of age) were found to have progression of keratoconus based on postoperative topographic data (Mean age 23.00 years, 55.6% female, total follow-up 2 to 10 years) CONCLUSION: ICRS implantation showed long-term improvement and stability in visual and topographic results in a large case series of patients with keratoconus. Only a minimal rate of progression was detected in young patients. However, further prospective studies need to be conducted to better define predictability of postoperative visual outcomes and progression.
Collapse
Affiliation(s)
- E L Warrak
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon.
| | - H A Serhan
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon
| | - J G Ayash
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon
| | - C H Wahab
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon
| | - T A Baban
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon
| | - R C Daoud
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon
| | - F K Sammouh
- Department of Ophthalmology, Saint George Hospital - University Medical Center, Beirut, Lebanon
| |
Collapse
|
9
|
Long-term safety of in-the-bag implantation of a supplementary intraocular pinhole. J Cataract Refract Surg 2020; 46:888-892. [DOI: 10.1097/j.jcrs.0000000000000163] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Eliaçık M, Kırgız A, Tülü Aygün B. Evaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: five year follow-up. Curr Eye Res 2020; 45:1359-1363. [PMID: 32228114 DOI: 10.1080/02713683.2020.1749667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
To evaluate the change in the position of intrastromal corneal ring segments (ICRS) implanted in keratoconus patients within five years of implantation. Participants in this study included keratoconus patients who received Keraring 10 ICRS implantation and had a follow-up time of at least 5 years. The distances from apex to anterior corneal surface (AA), from outer basal corner to posterior corneal surface (BP), and from inner basal corner to posterior corneal surface (CP) were measured at every postoperative visit (6 months, 1 year, 3 years, and 5 years) and compared to each other. Thirty eyes of 22 patients were included. The CP showed a statistically significant decrease at all 15 time points (p < .001); however, no statistically significant difference was found at 5 years regarding AA or BP (p > .05 for all). Triangular ICRS implanted in keratoconus patients remained stable for five years without any complications, which is an extremely important aspect of ICRS surgery. The only difference was a slight posterior movement of the inner basal corner, although without anterior chamber perforation.
Collapse
Affiliation(s)
- Mustafa Eliaçık
- School of Medicine, Department of Ophthalmology, Medipol University , Istanbul, Turkey
| | - Ahmet Kırgız
- Ophthalmology Department, Beyoglu Eye Training and Research Hospital, University of Health Sciences , Istanbul, Turkey
| | - Beril Tülü Aygün
- Ophthalmology Department, Beyoglu Eye Training and Research Hospital, University of Health Sciences , Istanbul, Turkey
| |
Collapse
|
11
|
Anatomical and Visual Effects of the MyoRing Implantation Measured by the ABCD Keratoconus Grading System. Eye Contact Lens 2020; 46:52-56. [DOI: 10.1097/icl.0000000000000595] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Trindade BL, Trindade FC, Trindade CL. Intraocular pinhole implantation for irregular astigmatism after planned and unplanned posterior capsule opening during cataract surgery. J Cataract Refract Surg 2019; 45:372-377. [DOI: 10.1016/j.jcrs.2018.11.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 11/13/2018] [Accepted: 11/17/2018] [Indexed: 10/27/2022]
|
13
|
Lohchab M, Prakash G, Arora T, Maharana P, Jhanji V, Sharma N, Vajpayee RB. Surgical management of peripheral corneal thinning disorders. Surv Ophthalmol 2018; 64:67-78. [PMID: 29886126 DOI: 10.1016/j.survophthal.2018.06.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 06/01/2018] [Accepted: 06/04/2018] [Indexed: 10/14/2022]
Abstract
The peripheral corneal thinning disorders are associated with degenerative, autoimmune, or infective causes. Corneal thinning can subsequently affect the visual acuity either by inducing severe astigmatism or by progressive involvement of the central cornea. In addition to this, the integrity of the eye is at risk. Medical management is necessary to address the underlying inflammatory or infectious causes; however, most of the cases require surgical intervention for tectonic support or for visual rehabilitation in patients with severe astigmatism. Preoperative investigations help in mapping the corneal curvature and thickness, thereby facilitating planning of treatment. Routine corneal transplantation techniques do not yield good results in peripheral corneal thinning disorders. Various surgical modifications have been described to manage these challenging cases. We review the available literature on causes and management of peripheral corneal thinning disorders.
Collapse
Affiliation(s)
- Monica Lohchab
- Cornea and Phacorefractive services, Guru Nanak Eye Centre, Maulana Azad Medical College, New Delhi, India
| | - Gaurav Prakash
- NMC eye care, New Medical Centre Specialty Hospital, Abu Dhabi, UAE
| | - Tarun Arora
- Eye Care Centre, Princess Margaret Hospital, Nassau, New Providence, Bahamas
| | - Prafulla Maharana
- RP Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Vishal Jhanji
- University of Pittsburgh School of Medicine, Pittsburgh, USA
| | - Namrata Sharma
- RP Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
| | - Rasik B Vajpayee
- Vision Eye Institute, Melbourne, Australia; Royal Victorian Eye and Ear Hospital, Melbourne, Australia; North West Academic Centre, University of Melbourne, Australia.
| |
Collapse
|
14
|
Sedaghat MR, Momeni-Moghaddam H, Belin MW, Zarei-Ghanavati S, Akbarzadeh R, Sabzi F, Yekta AA, Sadeghi Allahabadi J. Changes in the ABCD Keratoconus Grade After Intracorneal Ring Segment Implantation. Cornea 2018; 37:1431-1437. [PMID: 29863546 DOI: 10.1097/ico.0000000000001648] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess the changes in the ABCD keratoconus staging system 6 months after intracorneal ring segment implantation. METHODS Fifty eyes of 50 patients with keratoconus who were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil) using the femtosecond laser were assessed. Preoperative and postoperative assessments included determination of distance uncorrected visual acuity and distance corrected visual acuity (DCVA), refraction, and Scheimpflug tomography with the Pentacam HR. In the ABCD keratoconus staging system, the elements A, B, C, and D stand for anterior and posterior radii of curvature in a 3.0-mm zone centered on the thinnest point (TP), corneal thickness at the TP, and DCVA, respectively. RESULTS Keraring implantation produced significant flattening changes (preoperatively vs. postoperatively) in the anterior (6.60 ± 0.48 vs. 7.22 ± 0.57 mm, P < 0.001) and posterior (4.99 ± 0.47 vs. 5.16 ± 0.53 mm, P = 0.002) radii of curvature of the 3-mm zone centered on the corneal TP associated with a statistically significant improvement in the DCVA (0.56 ± 0.24 vs. 0.70 ± 0.22 in the decimal notation, P = 0.001) with no significant change in the corneal thickness at the TP (P = 0.285). The most changes occurred in element A of the ABCD keratoconus classification. Also, a 1-stage change was observed for element B, whereas elements C and D did not show changes in their postoperative stages after ring implantation. ABCD keratoconus staging before ring implantation was A2B3C2D1 and changed to A1B2C2D1 6 months after surgery. CONCLUSIONS The ABCD staging system provides a more comprehensive guide that better illustrates the structural changes and visual acuity as one aspect of visual function after the implantation of the intrastromal corneal ring segments.
Collapse
Affiliation(s)
| | - Hamed Momeni-Moghaddam
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran.,Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran
| | - Michael W Belin
- Department of Ophthalmology and Vision Science, University of Arizona, Tucson, AZ
| | | | - Reyhaneh Akbarzadeh
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Fatemeh Sabzi
- Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Abbas-Ali Yekta
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | | |
Collapse
|
15
|
Frisch IB, Rabsilber TM, Becker KA, Reuland AJ, Auffarth GU. Comparison of Anterior Chamber Depth Measurements using Orbscan II and IOLMaster. Eur J Ophthalmol 2018; 17:327-31. [PMID: 17534811 DOI: 10.1177/112067210701700308] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany). METHODS In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115 patients using Orbscan II and IOLMaster. Average patient age was 52.9+/-19.4 (range 16 to 87) years. ACD was evaluated from corneal epithelium to anterior lens surface. Additionally, axial length (AL) was measured using the Zeiss IOLMaster to calculate the regression coefficient between AL and ACD. RESULTS Mean ACD was 3.35+/-0.43 mm (range 2.01 mm to 4.37 mm) using Orbscan II and 3.36+/-0.41 mm (range 2.09 mm to 4.24 mm) using IOLMaster. Mean total axial length was 24.04 mm +/- 2.1 mm (range 20.7 mm to 31.41 mm). The linear regression coefficient of ACD between both methods was R=0.95. ACD and AL correlated only slightly (R=0.57). The Spearman coefficients of rank correlation were 0.94 and 0.61, respectively. A p value less than 0.01 (paired Wilcoxon test) was considered statistically significant. However, a significant difference was not calculated comparing ACD measurements using both systems and the Bland-Altman-Plot showed 95% of the differences ranging between 0.25 and -0.27 mm. CONCLUSIONS Regarding clinical application, both systems seem to be equally good and interchangeable in clinical practice in terms of ACD evaluation.
Collapse
Affiliation(s)
- I B Frisch
- Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany
| | | | | | | | | |
Collapse
|
16
|
Refractive Errors & Refractive Surgery Preferred Practice Pattern®. Ophthalmology 2018; 125:P1-P104. [DOI: 10.1016/j.ophtha.2017.10.003] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 10/02/2017] [Indexed: 11/19/2022] Open
|
17
|
Heikal MA, Abdelshafy M, Soliman TT, Hamed AM. Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up. Clin Ophthalmol 2016; 11:81-86. [PMID: 28096650 PMCID: PMC5207472 DOI: 10.2147/opth.s120267] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). Patients and methods A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the period from January 5, 2015, to February 28, 2016. Results Thirty eyes of 20 patients were included in this study. The mean age of patients was 27.43±3.57 years. Eleven patients (55%) were female and nine patients (45%) were male. Keraring segments were successfully implanted in all eyes. There were no complications or need for ring repositioning. The follow-up period was 6 months postoperatively. There was a significant improvement in the mean logarithm of the minimum angle of resolution (LogMAR) of uncorrected visual acuity (UCVA) after Keraring segment implantation from 1.5±0.23 preoperatively to 0.54±0.16 at 6 months postoperatively (P=0.001). The preoperative mean LogMAR of best-corrected visual acuity (BCVA) was 0.85±0.17. At 1 month postoperatively, it was 0.35±0.15; at 3 months postoperatively, it was 0.26±0.11, and at 6 months postoperatively, it was 0.14±0.07 (P=0.001). The mean preoperative maximum keratometric value for 3 mm pupil in diopters (K max) significantly decreased from 55.85±5.44 preoperatively (N=30) to 44.05±1.64 D at 6 months postoperatively (P=0.001). There was a statistically significant reduction in the mean preoperative spherical equivalent from −5.43±1.76 D preoperatively to −2.43±0.95 D at 6 months postoperatively. No statistically significant differences were detected between 1 and 3 months of follow-up regarding the visual and refractive outcomes. Conclusion Analysis of the outcomes after Keraring ICRS implantation showed a significant postoperative corneal flattening with a subsequent increase in UCVA and BCVA. Using the femtosecond laser for tunnel creation made the procedure easy and fast with an accurate precise depth of implantation and reduced the risk of operative and postoperative complications.
Collapse
|
18
|
Giacomin NT, Mello GR, Medeiros CS, Kiliç A, Serpe CC, Almeida HG, Kara-Junior N, Santhiago MR. Intracorneal Ring Segments Implantation for Corneal Ectasia. J Refract Surg 2016; 32:829-839. [DOI: 10.3928/1081597x-20160822-01] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 07/05/2016] [Indexed: 12/20/2022]
|
19
|
Janani L, Jadidi K, Mosavi SA, Nejat F, Naderi M, Nourijelyani K. MyoRing Implantation in Keratoconic Patients: 3 years Follow-up Data. J Ophthalmic Vis Res 2016; 11:26-31. [PMID: 27195081 PMCID: PMC4860982 DOI: 10.4103/2008-322x.180713] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Purpose: To evaluate long-term follow-up data on implantation of a full-ring intra-corneal implant (MyoRing) for management of keratoconus. Methods: A total of 40 keratoconic eyes of 37 consecutive patients who had undergone MyoRing implantation using the Pocket Maker microkeratome (Dioptex, GmbH, Linz, Austria) and completed 3 years of follow-up appointments were included in this retrospective study. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction and keratometry (K) readings were measured and evaluated preoperatively, and 3 years, postoperatively. Results: No intraoperative complications were observed in this case series. Three years postoperatively, there was a significant improvement in UDVA, CDVA, K readings, spherical equivalent (SE), and manifest sphere and cylinder (P < 0.05 for all comparisons). UDVA was significantly improved from 1.14 ± 0.27 to 0.30 ± 0.21 LogMAR (P = 0.001), CDVA was also improved from 0.52 ± 0.23 to 0.18 ± 0.12 LogMAR (P = 0.001), SE was decreased by 4.35 diopters (D) and average keratometric values were reduced by 2.34 D (P = 0.001). Overall, 81% of subjects were moderately to highly satisfied 3 years after surgery and 64.90% agreed to have the fellow eye implanted with MyoRing. Conclusion: MyoRing implantation using the Pocket Maker microkeratome was found to be a minimally invasive procedure for improving visual acuity and refraction in the majority of the patients with keratoconus.
Collapse
Affiliation(s)
- Leila Janani
- Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran, Iran
| | - Khosrow Jadidi
- Department of Ophthalmology, Bina Eye Hospital Research Center, Tehran, Iran
| | | | - Farhad Nejat
- Department of Ophthalmology, Bina Eye Hospital Research Center, Tehran, Iran
| | - Mostafa Naderi
- Department of Ophthalmology, Bina Eye Hospital Research Center, Tehran, Iran
| | - Keramat Nourijelyani
- Department of Epidemiology and Biostatistics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
20
|
Depth evaluation of intended vs actual intacs intrastromal ring segments using optical coherence tomography. Eye (Lond) 2015; 30:102-10. [PMID: 26493037 DOI: 10.1038/eye.2015.202] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2015] [Accepted: 08/24/2015] [Indexed: 11/08/2022] Open
Abstract
PurposeEvaluation of actual vs intended intrastromal corneal ring segments (ICRS) implantation depth as measured by anterior segment optical coherence tomography (OCT)MethodsProspective study evaluating 30 Intacs segments implanted manually in 19 eyes of 15 patients suffering from keratoconus. Segment depth evaluation was performed using anterior segment OCT. Measurements were performed above and below the segment at 3 points in relation to the incision site. Statistical analysis was performed using the SAS software for ANOVA, matched t-test, and GLIMMIX procedure.ResultsIntacs segment depth was 153-μm shallower than intended (58% vs 80%). Segment layout demonstrated the proximal and distal portions to be 13-μm shallower and 12-μm deeper (on average), respectively. Intacs segment thickness does not influence implantation depth. Intacs segments implanted in the same eye do not share similar implantation depths. Stromal compression is likely to occur.ConclusionIntacs are implanted at a shallower depth than intended. The 'pocketing' stage prior to implantation most likely has a stronger effect on the segment's final implantation depth than does the incisions' depth.
Collapse
|
21
|
Reshaping procedures for the surgical management of corneal ectasia. J Cataract Refract Surg 2015; 41:842-72. [PMID: 25840308 DOI: 10.1016/j.jcrs.2015.03.010] [Citation(s) in RCA: 75] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Revised: 07/15/2014] [Accepted: 07/23/2014] [Indexed: 12/31/2022]
Abstract
UNLABELLED Corneal ectasia is a progressive, degenerative, and noninflammatory thinning disorder of the cornea. Recently developed corneal reshaping techniques have expanded the treatment armamentarium available to the corneal specialist by offering effective nontransplant options. This review summarizes the current evidence base for corneal collagen crosslinking, topography-guided photorefractive keratectomy, and intrastromal corneal ring segment implantation for the treatment of corneal ectasia by analyzing the data published between the years 2000 and 2014. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
|
22
|
Intrastromal corneal ring segment implantation (keraring 355°) in patients with central keratoconus: 6-month follow-up. J Ophthalmol 2015; 2015:916385. [PMID: 25685395 PMCID: PMC4313675 DOI: 10.1155/2015/916385] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Revised: 11/27/2014] [Accepted: 11/28/2014] [Indexed: 11/17/2022] Open
Abstract
We evaluate the efficacy and safety of Keraring 355° intrastromal corneal ring segment (ICRS) implantation aided by PocketMaker microkeratome for the correction of keratoconus. Patients underwent ICRS insertion using mechanical dissection with PocketMaker microkeratome and completed 6 months of follow-up. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, topographic findings, safety, efficacy index, and adverse events were reported for six months postoperatively. We evaluated 15 eyes of 15 patients (12 men) with a mean age of 28.87 ± 6.94 years (range 21–49 years). At final postoperative examination, there was a statistically significant reduction in the spherical equivalent refractive error compared to preoperative measurements (−5.46 ± 1.52 to −2.01 ± 1.63 D, P < 0.001). Mean preoperative UCVA (logMAR) before implantation was 0.79 ± 0.48, and postoperative UCVA was 0.28 ± 0.15, P = 0.001. Mean preoperative BSCVA (logMAR) before implantation was 0.36 ± 0.21; at final follow-up examination BSCVA was 0.18 ± 0.9, P = 0.009. Mean K decreased from 48.33 to 43.31 D, P < 0.001. All patients were satisfied with ICRS implantation; 86.7% were moderately to very happy with the results. No intraoperative or postoperative complications were demonstrated. This preliminary study shows that ICRS (Keraring 355°) implantation is an efficient, cost-effective, and minimally invasive procedure for improving visual acuity in nipple type keratoconic corneas.
Collapse
|
23
|
Yildirim A, Cakir H, Kara N, Uslu H, Gurler B, Ozgurhan EB, Colak HN. Corneal collagen crosslinking for ectasia after laser in situ keratomileusis: Long-term results. J Cataract Refract Surg 2014; 40:1591-6. [DOI: 10.1016/j.jcrs.2014.01.042] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 01/10/2014] [Accepted: 01/23/2014] [Indexed: 11/27/2022]
|
24
|
Shetty R, D'Souza S, Ramachandran S, Kurian M, Nuijts RMMA. Decision making nomogram for intrastromal corneal ring segments in keratoconus. Indian J Ophthalmol 2014; 62:23-8. [PMID: 24492498 PMCID: PMC3955066 DOI: 10.4103/0301-4738.126170] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Purpose: To create a nomogram for the insertion of intrastromal corneal ring segments (ICRS) (Intacs® ) in eyes with keratoconus. Setting: Tertiary eye care center in South India. Materials and Methods: This prospective, non-randomized, interventional case series used a self-designed decision-making nomogram for the selection of ICRS in keratoconus patients based on the centration of the cone, mean refractive spherical equivalent (MRSE), and mean keratometry (Km) values. The 3, 6, and 12 months clinical outcomes were compared to historical controls. Primary endpoints were improvement in uncorrected and best-corrected vision and change in the keratometric values. Results: Group A comprised of 52 eyes of 50 patients that followed the nomogram, while Group B comprised of 25 eyes of 23 non-nomogram historical controls matched for baseline parameters. In Group A, the uncorrected distance visual acuity (UDVA) improved from 0.16 ± 0.15 to 0.25 ± 0.16 (P < 0.001), corrected distance visual acuity (CDVA) from 0.58 ± 0.2 to 0.69 ± 0.21 (P = 0.022), MRSE from -5.41 ± 4.94 to -1.71 ± 2.88 (P < 0.001), Km from 51.77 ± 5.45 to 48.63 ± 4.37 (P < 0.001), and astigmatism reduced from 5.86 ± 2.61 to 4.91 ± 2.72 diopters (P < 0.001).In Group B, improvement in the average MRSE was from -6.44 ± 5.32 to -3.26 ± 2.82 (P < 0.013) and in the average Km from 53.64 ± 5.32 to 50.31 ± 5.02 (P < 0.001). Other parameters did not improve significantly. A statistically significant difference was present in the percentage of patients achieving a good clinical outcome between the two groups (P < 0.001; Chi-square). Conclusion: The nomogram provides a means to choose the appropriate ICRS, hence improving the outcome in patients with keratoconus.
Collapse
Affiliation(s)
- Rohit Shetty
- Head of Department, Refractive Surgery, Narayana Nethralaya Superspeciality Eye Institute, Bangalore, Karnataka, India
| | | | | | | | | |
Collapse
|
25
|
Jabbarvand M, Hashemian M, Hashemian H, Bazvand F, Khodaparast M. Femtosecond Laser-Assisted MyoRing Implantation in Postoperative LASIK Ectasia. J Refract Surg 2014; 30:462-6. [DOI: 10.3928/1081597x-20140521-02] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Accepted: 03/04/2014] [Indexed: 11/20/2022]
|
26
|
Hashemi H, Yazdani-Abyaneh A, Beheshtnejad A, Jabbarvand M, Kheirkhah A, Ghaffary SR. Efficacy of intacs intrastromal corneal ring segment relative to depth of insertion evaluated with anterior segment optical coherence tomography. Middle East Afr J Ophthalmol 2014; 20:234-8. [PMID: 24014988 PMCID: PMC3757634 DOI: 10.4103/0974-9233.114800] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
AIM To evaluate the effect of implantation depth of Intacs microthin prescription inserts (Addition Technology Inc, Fremont, California) on visual and topographic outcomes in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasias. SETTINGS AND DESIGN Retrospective, observational case series. MATERIALS AND METHODS In this case series, 16 eyes of 12 patients were evaluated. All cases were post-LASIK ectasia that had undergone intrastromal corneal ring segment (ICRS) implantation. The planned insertion depth was 70% of stromal thickness using a manual dissector. At least 12 months postoperatively, all eyes underwent Visante (Carl Zeiss Meditec) AS-OCT to determine insertion depth. Cases were categorized into 3 groups based on the measured implantation depth: 40-59% thickness; 60-79% thickness; and ≥80% thickness. Visual, refractive and topographic outcomes were evaluated relative to implantation depth. RESULTS The lowest improvement in the study parameters ocurred when the implantation depth was ≥80%. In this group, uncorrected visual acuity (UCVA) and best spectacle corrected VA (BSCVA) improved less than 0.5 lines. Manifest refractive spherical equivalent (MRSE) and mean keratometry (Km) change was less than 0.5 diopters (D). The greatest improvements were observed with implantation depth of 60-79% where UCVA and BSCVA increased by 4.5 and 2.5 lines respectively, and MRSE and Km changed by approximately 2.00 D. Less improvement was found when ICRS were implanted between 40-59% of stromal thickness. CONCLUSION Implantation of ICRS greater than 80% of stromal thickness may have no effect on visual and topographic status.
Collapse
Affiliation(s)
- Hassan Hashemi
- Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran ; Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | | | | | | | | | | |
Collapse
|
27
|
Lam K, Rootman DB, Lichtinger A, Rootman DS. Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking. Digit J Ophthalmol 2013; 19:1-5. [PMID: 23794955 DOI: 10.5693/djo.02.2012.10.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Corneal ectasia is a serious complication of laser in situ keratomileusis (LASIK). We report the case of a 29-year-old man who underwent LASIK in both eyes and in whom corneal ectasia developed in the left eye 3 years after surgery. He was treated sequentially with intraocular pressure-lowering medication, intrastromal corneal ring segment (ICRS) implants, and collagen cross-linking. Vision improved and the ectasia stabilized following treatment. Combined ICRS implantation and collagen cross-linking should be considered early in the management of post-LASIK ectasia.
Collapse
Affiliation(s)
- Kay Lam
- Department of Ophthalmology, University of Toronto, Toronto, Ontario, Canada.
| | | | | | | |
Collapse
|
28
|
Tunc Z, Helvacioglu F, Sencan S. Evaluation of intrastromal corneal ring segments for treatment of keratoconus with a mechanical implantation technique. Indian J Ophthalmol 2013; 61:218-25. [PMID: 23571258 PMCID: PMC3730505 DOI: 10.4103/0301-4738.109519] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
PURPOSE To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation in patients with keratoconus using a mechanical implantation technique. MATERIALS AND METHODS Thirty eyes of 17 patients with keratoconus were enrolled. ICRSs (Keraring) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3-, 6-, and 12-month follow-ups were completed, and statistical analysis was performed. RESULTS The mean preoperative UDVA for all eyes was 1.36 ± 0.64 logMAR. At 12 months, the mean UDVA was 0.51 ± 0.28 logMAR (P = 0.001), and the mean preoperative CDVA was 0.57 ± 0.29 logMAR, which improved to 0.23 ± 0.18 (P = 0.001) at 1 year. There was a significant reduction in spherical equivalent refractive error from -6.42 ± 4.69 diopters (D) preoperatively to -1.26 ± 1.45 D (P = 0.001) at 1 year. In the same period, the mean K-readings improved from 49.38 ± 3.72 D to 44.43 ± 3.13 D (P = 0.001), and the mean ISAI improved from 7.92 ± 3.12 to 4.21 ± 1.96 (P = 0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during and or after surgery. CONCLUSION ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for keratoconus. All parameters improved by the 1-year follow-up.
Collapse
Affiliation(s)
- Zeki Tunc
- Department of Ophthalmology, Maltepe University School of Medicine, Istanbul, Turkey
| | | | | |
Collapse
|
29
|
Mitchell BM, Kanellopoulos AJ, Font RL. Post intrastromal corneal ring segments insertion complicated by Candida parapsilosis keratitis. Clin Ophthalmol 2013; 7:443-8. [PMID: 23467516 PMCID: PMC3589195 DOI: 10.2147/opth.s39963] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
This case report describes the clinical and histopathologic features, including molecular confirmation, of fungal keratitis after intrastromal corneal ring segments placement for keratoconus. A 52-year-old woman underwent insertion of Intacs(®) corneal implants for treatment of keratoconus. Extrusion of the implants was noted 5 months post insertion and replaced. Three months later, monocular infiltrates and an epithelial defect were observed. The Intacs were removed and the infiltrates were treated with ofloxacin and prednisolone acetate. Microbial cultures and stains were negative. The patient demonstrated flares and exacerbation one month later. Mycoplasma and/or fungus were suspected and treated without improvement. Therapeutic keratoplasty was performed 10 months following initial placement of the corneal ring implants. The keratectomy specimen was analyzed by light microscopy and a panfungal polymerase chain reaction assay. A histopathologic diagnosis of Candida parapsilosis keratitis was made and confirmed by polymerase chain reaction. One year postoperatively, a systemic workup of the patient was done with no signs of recurrence. This rare report of fungal keratitis following Intacs insertion is the first reported case of C. parapsilosis complicating Intacs implantation.
Collapse
Affiliation(s)
| | - A John Kanellopoulos
- Department of Ophthalmology, New York University Medical School, New York City, NY
| | - Ramon L Font
- Department of Ophthalmology, Ophthalmic Pathology Laboratory, Cullen Eye Institute, Baylor College of Medicine, Houston, TX, USA
| |
Collapse
|
30
|
Brenner LF, Alió JL, Vega-Estrada A, Baviera J, Beltrán J, Cobo-Soriano R. Indications for intrastromal corneal ring segments in ectasia after laser in situ keratomileusis. J Cataract Refract Surg 2012; 38:2117-24. [DOI: 10.1016/j.jcrs.2012.07.036] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2012] [Revised: 06/20/2012] [Accepted: 07/17/2012] [Indexed: 11/17/2022]
|
31
|
Niknam S, Shamshiri M, Shahrzad SS, Alipour A, Rajabi MB, Rajabi MT. Treatment of moderate to severe keratoconus with 6-mm Intacs SK. Int J Ophthalmol 2012; 5:513-6. [PMID: 22937516 DOI: 10.3980/j.issn.2222-3959.2012.04.21] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2011] [Accepted: 06/25/2012] [Indexed: 11/02/2022] Open
Abstract
AIM To evaluate the effect of Intacs SK corneal ring segment implant for treatment of patients with moderate to severe keratoconus, who have clear central cornea and cannot tolerate contact lens. METHODS In this prospective, non-comparative, interventional case series study performed in Dena Hospital, Shiraz, Iran, thirty-seven eyes of thirty-six patients with moderate to severe keratoconus, clear central cornea, and contact lens intolerance were enrolled and underwent Intacs SK corneal ring segment implantation. Preoperatively, uncorrected distance visual acuity (UCDVA), best-corrected distance visual acuity (BCDVA), central corneal thickness(CCT) and average keratometry (Av-K) were measured and compared with post-operative results at one week, one month, three months, and six months. RESULTS Mean preoperative UCDVA and BCDVA were (1.32±0.31)logMAR and (1.07±0.27)logMAR, respectively. Av-K was (52.13±0.39)D, and the CCT was (432±39.5)µm. Post-operative examinations showed a clinically significant improvement in both UCDVA and BCDVA (P<0.001). There was also a significant effect based on the time of assessment on both UCDVA and BCDVA and both parameters had a continuous improvement during the follow-up period. Three months after operation there was a statistical significant reduction of Av-K (P=0.0001), but there were no significant changes in CCT (P=0.149). CONCLUSION Intacs SK corneal ring segment implants seem to be a safe and effective treatment option for patients who have keratoconus, clear central cornea, and contact lens intolerance.
Collapse
Affiliation(s)
- Sasan Niknam
- Cornea Unit, Dr Khodadoust Eye Hospital, Shiraz, Iran
| | | | | | | | | | | |
Collapse
|
32
|
Ortiz S, Pérez-Merino P, Alejandre N, Gambra E, Jimenez-Alfaro I, Marcos S. Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments. BIOMEDICAL OPTICS EXPRESS 2012; 3:814-24. [PMID: 22567577 PMCID: PMC3342189 DOI: 10.1364/boe.3.000814] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2012] [Revised: 03/16/2012] [Accepted: 03/21/2012] [Indexed: 05/19/2023]
Abstract
Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) was used to characterize three-dimensionally (3-D) corneal topography in keratoconus before and after implantation of intracorneal ring segments (ICRS). Previously described acquisition protocols were followed to minimize the impact of the motions of the eye. The collected set of images was corrected from distortions: fan (scanning) and optical (refraction). Custom algorithms were developed for automatic detection and classification of volumes in the anterior segment of the eye, in particular for the detection and classification of the implanted ICRS. Surfaces were automatically detected for quantitative analysis of the corneal elevation maps (fitted by biconicoids and Zernike polynomials) and pachymetry. Automatic tools were developed for the estimation of the 3-D positioning of the ICRS. The pupil center reference was estimated from the segmented iris volume. The developed algorithms are illustrated in a keratoconic eye (grade III) pre- and 30 days post-operatively after implantation of two triangular-section, 0.3-mm thick Ferrara ring segments. Quantitative corneal topographies reveal that the ICRS produced a flattening of the anterior surface, a steepening of the posterior surface, meridional differences in the changes in curvature and asphericity, and increased symmetry of the anterior topography. Optical distortion correction through the ICRS (of a different refractive index from the cornea) allowed accurate pachymetric estimates, which showed increased thickness in the ectatic area as well as in peripheral corneal areas. Automatic tools allowed estimation of the depth of the implanted ICRS ring, as well as its rotation with respect to the pupil plane. Anterior segment sOCT provided with fan and optical distortion correction and analysis tools is an excellent instrument for evaluating and monitoring keratoconic eyes and for the quantification of the changes produced by ICRS treatment.
Collapse
Affiliation(s)
- Sergio Ortiz
- Instituto de Óptica “Daza de Valdés”, Consejo Superior de Investigaciones Científicas, C/Serrano 121, 28006 Madrid, Spain
| | - Pablo Pérez-Merino
- Instituto de Óptica “Daza de Valdés”, Consejo Superior de Investigaciones Científicas, C/Serrano 121, 28006 Madrid, Spain
| | - Nicolas Alejandre
- Fundación Jiménez-Díaz, Avda. Reyes Católicos, 2, 28040, Madrid, Spain
| | - E. Gambra
- Instituto de Óptica “Daza de Valdés”, Consejo Superior de Investigaciones Científicas, C/Serrano 121, 28006 Madrid, Spain
| | - I. Jimenez-Alfaro
- Fundación Jiménez-Díaz, Avda. Reyes Católicos, 2, 28040, Madrid, Spain
| | - Susana Marcos
- Instituto de Óptica “Daza de Valdés”, Consejo Superior de Investigaciones Científicas, C/Serrano 121, 28006 Madrid, Spain
| |
Collapse
|
33
|
Elevation Changes of Central Posterior Corneal Surface After Intracorneal Ring Segment Implantation in Keratoconus. Cornea 2012; 31:387-95. [DOI: 10.1097/ico.0b013e31822481df] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
34
|
Abdelaziz L, Zadok D, Pikkel J, Garzozi H, Marcovich A, Nasser O. Collagen Corneal Cross-Linking followed by Intac Implantation in a Case of Post-PRK Ectasia. ACTA ACUST UNITED AC 2012. [DOI: 10.5005/jp-journals-10025-1013] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
ABSTRACT
Collagen corneal cross-linking (CXL) has proved to be effective in halting the progression of keratoconus and post-LASIK ectasia.
Post-photorefractive keratectomy (PRK) ectasia, a rare PRK complication, has been reported in only a few cases, although PRK is the oldest form of laser refractive surgery. CXL for post- PRK ectasia has not been reported yet.
Here is a case of a 22-year-old male who developed post- PRK ectasia more than 1 year after the procedure and was treated using CXL. A few months after CXL, an Intac (Addition Technology) was implanted due to contact lens intolerance.
How to cite this article
Barbara R, Zadok D, Pikkel J, Marcovich A, Garzozi H, Nasser O, Abdelaziz L, Barbara A. Collagen Corneal Cross-Linking followed by Intac Implantation in a Case of Post-PRK Ectasia. Int J Keratoco Ectatic Corneal Dis 2012;1(1):68-72.
Collapse
|
35
|
Abstract
ABSTRACT
Purpose
To demonstrate treatment options for keratoconus using MyoRing intracorneal implant in central and noncentral cones.
Materials and methods
Five eyes with central and noncentral cones were compared in a retrospective study.
Results
In central cones the maximum of the flattening effect is in the corneal center while in noncentral cones the maximum of the flattening is in area of the cone.
Conclusion
No matter where the cone location is the implantation of MyoRing intracorneal implants always results in a regularization of the central cornea.
How to cite this article
Daxer A. MyoRing for Central and Noncentral Keratoconus. Int J Kerat Ect Cor Dis 2012;1(2):117-119.
Collapse
|
36
|
Oruçoglu F, Gürsoy T, Göker S. Intracuring: intrastromal corneal application of dental flowable composite. Ophthalmic Surg Lasers Imaging Retina 2011; 42:509-13. [PMID: 22074706 DOI: 10.3928/15428877-20111017-04] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2010] [Accepted: 07/18/2011] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND OBJECTIVE To evaluate an intracuring method by changing the corneal curvature. MATERIALS AND METHODS An intrastromal tunnel was created by femtosecond laser in five cadaveric sheep eyes. Dental flowable restorative composite was used to fill the tunnel. A light-emitting diode light was applied for polymerization for 20 seconds. Flat plastic material was used for pressure on the cornea during polymerization. Keratometric measurements were obtained in all eyes using a rotating Scheimpflug camera. RESULTS Remarkable changes on the corneal curvature were observed after the intracuring method. Inferior or inferonasal flattening and opposite steepening was observed in all sheep eyes. The average flattening effect of this method was 10.6 diopters. CONCLUSION This new application may be a promising technique for the treatment of keratoconus. The application of this technique in humans could offer improved treatment options in the future.
Collapse
|
37
|
Tunc Z, Helvacioglu F, Sencan S. Evaluation of intrastromal corneal ring segments for treatment of post-LASIK ectasia patients with a mechanical implantation technique. Indian J Ophthalmol 2011; 59:437-43. [PMID: 22011487 PMCID: PMC3214413 DOI: 10.4103/0301-4738.86310] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Aim: To evaluate the clinical outcomes of Keraring segment implantation in patients with post- laser-assisted in situ keratomileusis (LASIK) ectasia, using a mechanical implantation technique. Materials and Methods: Twelve eyes of 10 patients with post-LASIK ectasia were enrolled. Intracorneal ring segments (ICRS) were implanted after dissection of the tunnel using Tunc's specially designed dissector under suction. A complete ophthalmic examination was performed, including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent, keratometric (K) readings, inferosuperior asymmetry index (ISAI), and ultrasound pachymetry. All 3, 6, and 12-month follow-ups were completed, and statistical analysis was performed. Results: The mean preoperative UDVA for all eyes was 1.28 ± 0.59 logMAR. At 12 months, the mean UDVA was 0.36 ± 0.19 logarithm of the Minimum Angle of Resolution (logMAR) (P=0.002), and the mean preoperative CDVA was 0.58 ± 0.3 logMAR, which improved to 0.15 ± 0.12 (P=0.002) at 1 year. There was a significant reduction in cylindrical refractive and spherical equivalent refractive error from –5.29 ± 2.47 diopters (D) and –5.54 ± 5.04 D preoperatively to –1.47 ± 0.71 D and –0.74 ± 1.07 D (P=0.001, P=0.002), respectively, at 1 year. In the same period, the mean K- readings improved from 47.93 ± 4.84 D to 40.87 ± 2.36 D (P=0.002), and the mean ISAI improved from 5.34 ± 3.05 to 2.37 ± 1.68 (P=0.003). No significant changes in mean central corneal thickness were observed postoperatively. There were no major complications during or after surgery. Conclusion: ICRS implantation using a unique mechanical dissection technique is a safe and effective treatment for post-LASIK ectasia. All parameters showed improvement at 1-year follow-up.
Collapse
Affiliation(s)
- Zeki Tunc
- Department of Ophthalmology, Maltepe University School of Medicine, Istanbul, Turkey.
| | | | | |
Collapse
|
38
|
Clinical characterization of corneal ectasia after myopic laser in situ keratomileusis based on anterior corneal aberrations and internal astigmatism. J Cataract Refract Surg 2011; 37:1291-9. [DOI: 10.1016/j.jcrs.2010.12.063] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2010] [Revised: 12/13/2010] [Accepted: 12/13/2010] [Indexed: 11/20/2022]
|
39
|
|
40
|
Alio JL, Piñero DP, Daxer A. Clinical outcomes after complete ring implantation in corneal ectasia using the femtosecond technology: a pilot study. Ophthalmology 2011; 118:1282-90. [PMID: 21440940 DOI: 10.1016/j.ophtha.2010.12.012] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2010] [Revised: 08/18/2010] [Accepted: 12/12/2010] [Indexed: 10/18/2022] Open
Abstract
PURPOSE To evaluate the clinical outcomes after implantation of the MyoRing (DIOPTEX GmBH, Linz, Austria) by means of femtosecond laser technology in eyes with corneal ectasia. DESIGN Retrospective, consecutive, nonrandomized, case series. PARTICIPANTS A total of 12 eyes of 11 patients with ages ranging from 17 to 50 years were included. All cases were diagnosed with corneal ectasia according to the standard criteria: 1 case of post-LASIK ectasia and 11 cases of keratoconus. All cases presented with reduced best spectacle-corrected visual acuity, contact lens intolerance or discomfort, and central corneal thickness of more than 350 μm. METHODS MyoRing inserts of 280 μm in thickness and 5 mm in diameter were implanted in all cases into an intrastromal corneal pocket created by means of femtosecond technology. Visual, refractive, corneal topography, and pachymetric changes were evaluated during a 6-month follow-up. In addition, corneal biomechanical changes were evaluated by means of the Ocular Response Analyzer (Reichert, Buffalo, NY). MAIN OUTCOME MEASURES Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, keratometry, corneal asphericity, corneal higher-order aberrations, pachymetry, corneal hysteresis (CH), and corneal resistance factor (CRF). RESULTS A significant improvement in UDVA was observed 1 week after surgery (P=0.001), which was consistent with the significant reduction in sphere (P=0.002) and cylinder (P=0.004). No significant changes were detected in these parameters afterward (P ≥ 0.263). Furthermore, a significant corneal flattening of a mean value of 8.03 diopters (D) was found (P=0.005). This keratometric change was correlated with the magnitude of corneal coma-like aberrations (r=0.830, P=0.003) and the CRF (r=-0.782, P=0.008). In regard to aberrometry, a statistically significant increase in primary spherical aberration was found 1 month after surgery (P=0.001). In addition, a significant reduction in higher-order corneal aberrations was found 3 to 6 months after surgery (P=0.027). Significant corneal thickening was also observed postoperatively in the central, nasal, and temporal areas (P ≤ 0.013). No statistically significant changes were detected (P ≥ 0.176) in corneal biomechanics. Explantation was performed in a very advanced keratoconus because of the extremely poor visual outcome. CONCLUSIONS MyoRing implantation using femtosecond technology in keratoconus allows successful corneal modeling, although the use of large diameters is advisable.
Collapse
Affiliation(s)
- Jorge L Alio
- Vissum/Instituto Oftalmológico de Alicante, Spain.
| | | | | |
Collapse
|
41
|
Woodward MA, Randleman JB. Corneal Ectasia. Cornea 2011. [DOI: 10.1016/b978-0-323-06387-6.00175-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
42
|
Renesto ADC, Campos M. Intrastromal Corneal Ring Segments. Cornea 2011. [DOI: 10.1016/b978-0-323-06387-6.00176-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
43
|
Madar J, Proust H, Matonti F, Conrath J, Ridings B, Hoffart L. [New therapeutic approach of keratoconus with intracorneal ring segments aided by femtosecond laser (Tecnolas Perfect Vision): indications, operating technique and results]. J Fr Ophtalmol 2010; 34:2-9. [PMID: 21112667 DOI: 10.1016/j.jfo.2010.09.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2009] [Accepted: 09/20/2010] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To assess the results of intracorneal ring segment implantation assisted by the Tecnolas Perfect Vision(®) femtosecond laser (Heidelberg, Germany). SETTINGS Retrospective observational study. METHODS The patients were operated on with the Tecnolas Perfect Vision(®) femtosecond laser. The following parameters were evaluated before and after surgery: uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), corneal topography, wavefront analysis, and central corneal thickness. The Wilcoxon test was used for statistical analysis. RESULTS Seventeen eyes of 15 patients were included. The mean follow-up was 6.9±0.71 months. Significant improvement of UCVA and BCVA was observed in 82.35% (P=0.027) and 94.12% (P=0.003) of the eyes, respectively. The subjective refraction showed a significant decrease of the sphere from -10.29±5.54 to -6.5±5.03D (P=0.002). The subjective cylinder significantly decreased from 5.43±3.20 to 3.69±2.30D (P=0.026). The SAI also decreased significantly (P=0.011). CONCLUSION Femtosecond-assisted intracorneal ring segment implantation is an effective treatment for corneal ectasia. Further studies are needed to improve surgical parameters and outcomes.
Collapse
Affiliation(s)
- J Madar
- Service d'ophtalmologie, hôpital de la Timone, 264, rue Saint-Pierre, 13385 Marseille cedex 5, France.
| | | | | | | | | | | |
Collapse
|
44
|
Bamashmus M, Saleh MF, Abdulrahman M, Al-Kershy N. Reasons for not performing LASIK in refractive surgery candidates in Yemen. Eur J Ophthalmol 2010; 20:858-64. [PMID: 20383849 DOI: 10.1177/112067211002000508] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To determine and analyze the reasons that laser in situ keratomileusis (LASIK) was not performed in patients who requested refractive surgical correction of their refractive errors. METHODS A retrospective observational study was performed in Yemen Magrabi Hospital between June 2005 and October 2006; the case records of 1596 new consecutive patients who presented for refractive surgery at our refractive surgery unit were reviewed. Data on the ocular status, refractive problems, and investigations performed were analyzed. The reasons for not performing LASIK in the cases that were rejected were recorded and analyzed. RESULTS A total of 1191 patients (74.6%) were advised to have LASIK of the 1596 patients examined. LASIK was not advised in 405 patients (25.4%). The most common reasons for rejecting LASIK were suboptimal central corneal thickness (25.9%), high myopia >-11.00 D (17.0%), keratoconus (15.5%), cataract (11.4%), and suspicious corneal topography (forme fruste keratoconus) (9.4%). CONCLUSIONS Patients who request refractive surgery have a variety of problems and attention must be given to these patients. Suboptimal corneal thickness, high amount of refractive error, and keratoconus were found to be the leading causes of not performing LASIK in Yemeni patients.
Collapse
Affiliation(s)
- Mahfouth Bamashmus
- Eye Department, Faculty of Medicine and Health Sciences, Sana'a University, Magrabi Eye Hospital, Sana'a, Republic of Yemen.
| | | | | | | |
Collapse
|
45
|
Implantation of new intracorneal ring segments after segment explantation for unsuccessful outcomes in eyes with keratoconus. J Cataract Refract Surg 2010; 36:1303-10. [DOI: 10.1016/j.jcrs.2010.02.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2009] [Revised: 02/02/2010] [Accepted: 02/10/2010] [Indexed: 10/19/2022]
|
46
|
Pérez-Merino P, Parra F, Ibares-Frías L, Gallego P, Vázquez-Lasa B, Benito L, San Román J, Martínez-García C, Merayo-Lloves J. Clinical and pathological effects of different acrylic intracorneal ring segments in corneal additive surgery. Acta Biomater 2010; 6:2572-9. [PMID: 20080217 DOI: 10.1016/j.actbio.2010.01.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2009] [Revised: 12/17/2009] [Accepted: 01/11/2010] [Indexed: 11/19/2022]
Abstract
The objective of this work was to evaluate the potential use of less stiff materials based on acrylic copolymers of methyl methacrylate/2-ethylhexyl acrylate (MMA/EHA) as devices to correct, stabilize and improve the effect of poly(methyl methacrylate) (PMMA) intracorneal ring segments. MMA/EHA and PMMA intracorneal ring segments were surgically implanted in the corneas of Lohmann Classic hens. The effects of the intracorneal ring segments were assessed by optical measurements and corneal tolerance was evaluated through biomicroscopic examination over a 90-day observation period and by conventional histology. The experimental results demonstrated that the intracorneal ring segments made of MMA/EHA copolymers provided a significant change in the corneal curvature and an improved in vivo response compared to those obtained for PMMA rings, which was attributed to the higher flexibility of the copolymeric materials, indicating that these systems might be considered suitable as an alternative to those currently used, for application in clinical practice.
Collapse
Affiliation(s)
- P Pérez-Merino
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Ferrer C, Alió JL, Montañés AU, Pérez-Santonja JJ, Diaz del Rio MA, de Toledo JA, Teus MA, Javaloy J. Causes of intrastromal corneal ring segment explantation: Clinicopathologic correlation analysis. J Cataract Refract Surg 2010; 36:970-7. [DOI: 10.1016/j.jcrs.2009.12.042] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2009] [Revised: 11/27/2009] [Accepted: 12/03/2009] [Indexed: 10/19/2022]
|
48
|
Torquetti L, Ferrara P. Intrastromal corneal ring segment implantation for ectasia after refractive surgery. J Cataract Refract Surg 2010; 36:986-90. [DOI: 10.1016/j.jcrs.2009.12.034] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2009] [Revised: 12/10/2009] [Accepted: 12/10/2009] [Indexed: 10/19/2022]
|
49
|
Liu A, Manche EE. Traumatic shattering of intrastromal corneal ring segments. J Cataract Refract Surg 2010; 36:1042-4. [PMID: 20494780 DOI: 10.1016/j.jcrs.2010.03.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2009] [Revised: 12/19/2009] [Accepted: 12/21/2009] [Indexed: 11/18/2022]
Abstract
Long-term stability of intrastromal corneal ring segments is important in maintaining patients' corrected distance visual acuity and avoiding injury to the local tissues. We report a case of traumatic shattering of intrastromal segments due to blunt trauma, with successful removal of the fragments.
Collapse
Affiliation(s)
- Anthony Liu
- Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, California 94305, USA
| | | |
Collapse
|
50
|
Piñero DP, Alio JL. Intracorneal ring segments in ectatic corneal disease - a review. Clin Exp Ophthalmol 2010; 38:154-67. [DOI: 10.1111/j.1442-9071.2010.02197.x] [Citation(s) in RCA: 146] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|