1
|
Abstract
Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these techniques sometimes fail to determine the specific cause of PHV dysfunction, which is crucial to the selection of the appropriate treatment strategy. Multidetector-row CT (MDCT) can be of additional value in diagnosing the specific cause of PHV dysfunction and provides valuable complimentary information for surgical planning in case of reoperation. Cardiac magnetic resonance imaging (CMR) has limited value in the evaluation of biological PHV dysfunction. In this Review, we discuss the use of established imaging modalities for the detection of left-sided mechanical and biological PHV dysfunction and discuss the complementary role of MDCT in this context.
Collapse
|
2
|
Totaro P, Argano V. Reply to the Editor. J Thorac Cardiovasc Surg 2008. [DOI: 10.1016/j.jtcvs.2007.10.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
3
|
Aslam AK, Aslam AF, Vasavada BC, Khan IA. Prosthetic heart valves: Types and echocardiographic evaluation. Int J Cardiol 2007; 122:99-110. [PMID: 17434628 DOI: 10.1016/j.ijcard.2006.12.037] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2006] [Revised: 12/15/2006] [Accepted: 12/30/2006] [Indexed: 11/30/2022]
Abstract
In the last five decades multiple different models of prosthetic valves have been developed. The purpose of this article is to provide a comprehensive source of information for the types and the echocardiographic evaluation of the prosthetic heart valves.
Collapse
Affiliation(s)
- Ahmad Kamal Aslam
- Division of Cardiology, Beth Israel Medical Center, 16th Street 1st Avenue, New York, NY 10003, USA.
| | | | | | | |
Collapse
|
4
|
Totaro P, Argano V. Patient–prosthesis mismatch after mitral valve replacement: Myth or reality? J Thorac Cardiovasc Surg 2007; 134:697-701. [PMID: 17723820 DOI: 10.1016/j.jtcvs.2007.04.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2007] [Revised: 03/19/2007] [Accepted: 04/11/2007] [Indexed: 12/01/2022]
Abstract
OBJECTIVE Determining the risk of patient-prosthesis mismatch after mitral valve replacement is still controversial. In this study, we aimed to clarify incidence and clinical implications of such a complication. The accuracy of preoperative prediction of patient-prosthesis mismatch using published in vitro hemodynamic parameters was also investigated. METHODS Ninety-two patients who underwent mitral valve replacement and received Carpentier-Edwards stented bioprosthesis (Edwards Lifesciences, LLC, Irvine Calif) were enrolled. Hemodynamic performances were evaluated at discharge, and the incidence of in vivo patient-prosthesis mismatch (indexed effective orifice area < or =1.2 cm2/m2) was evaluated. Correlation between in vivo patient-prosthesis mismatch and predicted patient-prosthesis mismatch, based on previously published in vitro hemodynamic parameters, was also investigated. RESULTS Five patients died within 30 days of the operation (5.4% mortality). Mean prosthesis size was 29.8 +/- 2. Mean postoperative effective orifice area and indexed effective orifice area (2.5 +/- 0.8 cm2 and 1.5 +/- 0.4 cm2/m2, respectively) compared favorably with those predicted in vitro (2.2 +/- 0.7 cm2 and 1.3 +/- 0.5 cm2/m2, respectively). In the subgroup of patients receiving prosthesis size of 27 or smaller, the difference reached statistical significance (2.47 +/- 0.83 and 1.61 +/- 0.7 for postoperative and predicted effective orifice areas, respectively; P < .001). Postoperative patient-prosthesis mismatch was recorded in 8 patients (8.6%), comparing favorably with the predicted patient-prosthesis mismatch (39% for overall population and 80% for patients receiving prosthesis size < or = 27). No significant correlation between size of prosthesis and early hemodynamic and clinical outcomes was shown. CONCLUSIONS In our study, stented mitral bioprostheses showed satisfactory postoperative hemodynamic performance, even in smaller prosthesis sizes (< or =27 mm). Risk of in vivo postoperative patient-prosthesis mismatch seems to be less relevant than preoperative risk prediction based on in vitro data. Further studies are needed to evaluate the potential clinical impact of mitral patient-prosthesis mismatch.
Collapse
|
5
|
Nakamura K, Asai T, Murakami M, Saitoh Y, Yamaguchi H. Early results of Bentall-type operations during the last 10 years: comparison of mechanical valves and stentless bioprostheses. Gen Thorac Cardiovasc Surg 2007; 55:6-11. [PMID: 17444165 DOI: 10.1007/s11748-006-0061-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
UNLABELLED OBJECTIVE. Various types of prostheses have been used for combined diseases of the aortic root and ascending aorta. METHODS All Bentall-type operations (n=64) between 1996 and 2005 were retrospectively studied, comparing different types of prosthesis in the aortic position. The patients were 29-87 years old (mean 59.5 +/- 14.0 years) and included 47 men and 17 women. Mechanical valves, stentless bioprostheses (Freestyle), stented bioprostheses, and a homograft were used in 31, 29, 3, and I patients, respectively. Early results, especially hemodynamics, were analyzed among two groups: mechanical valve group (M-group) and Freestyle group (F-group). RESULTS The average age was significantly higher in the F-group (62.8 +/- 12.7 years) than in the M-group (54.9 +/- 14.0 years) (P = 0.025). The implanted valve was significantly larger in the F-group (26.0 +/- 2.3 mm) than in the M-group (23.5 +/- 2.1mm) (P = 0.000). The estimated effective orifice area of the prosthesis was significantly larger in the F-group (2.23 +/- 0.38 cm2) than in the M-group (1.84 +/- 0.49 cm2) (P = 0.001). The pressure gradient across the prosthesis was significantly lower in the F-group (18.6 +/- 5.5 mmHg) than in the M-group (25.4 +/- 7.6 mmHg) (P = 0.001). CONCLUSION The Bentall-type procedure using the Freestyle valve has an advantage regarding hemodynamics compared to the procedure employing mechanical prostheses.
Collapse
Affiliation(s)
- Koki Nakamura
- Department of Cardiovascular Surgery, Shin-Tokyo Hospital, Nemoto 473-1, Matsudo, Chiba 271-0077, Japan.
| | | | | | | | | |
Collapse
|
6
|
Bridges CR, O'Brien SM, Cleveland JC, Savage EB, Gammie JS, Edwards FH, Peterson ED, Grover FL. Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement. J Thorac Cardiovasc Surg 2007; 133:1012-21. [PMID: 17382644 DOI: 10.1016/j.jtcvs.2006.11.028] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2005] [Revised: 11/01/2006] [Accepted: 11/16/2006] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The appropriate index of prosthesis internal orifice size and its effect on operative mortality after aortic valve replacement are controversial. We examined the association between several relevant indices and patient size on operative mortality. Indices examined included projected in vivo effective orifice area and geometric orifice area, with patient size defined as body surface area. METHODS A review of the Society of Thoracic Surgeons National Cardiac Database (2000-2004) yielded 48,722 patients who had isolated aortic valve replacement. This analysis is based on the cohort of 42,310 patients with the 8 most prevalent valve types with manufacturer's labeled sizes 19 mm through 29 mm. Multivariable logistic regression models were employed to determine the effects of body surface area, effective orifice area, geometric orifice area, and selected derived indices (eg, effective orifice area/body surface area) on risk-adjusted operative mortality. RESULTS In separate multivariable models, effective orifice area and geometric orifice area were both inversely correlated with operative mortality. However, an unanticipated finding was that with either effective orifice area or geometric orifice area held constant, body surface area was significantly and inversely correlated with operative mortality. When patients were stratified by effective orifice area, geometric orifice area, or manufacturer's labeled valve size and type, elevations in body surface area were associated with a decrease rather than an increase in operative mortality. CONCLUSIONS Prostheses with small geometric orifice area or small effective orifice area are associated with increased operative mortality after isolated aortic valve replacement. Even for valves with small effective orifice area, however, mortality decreases as body surface area increases. With respect to operative mortality, therefore, our results do not support using arbitrary cutoff values of effective orifice area/body surface area to determine the valve to utilize in a given patient.
Collapse
Affiliation(s)
- Charles R Bridges
- Department of Surgery, the University of Pennsylvania Health System, Philadelphia, Pa, USA.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Fukui T, Shibata T, Sasaki Y, Hirai H, Motoki M, Takahashi Y, Suehiro S. Long-term experience with the Sorin Bicarbon and Edwards Mira mechanical valve prostheses in the mitral position. Gen Thorac Cardiovasc Surg 2007; 55:91-7. [PMID: 17447506 DOI: 10.1007/s11748-006-0081-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVE Sorin Bicarbon (SB) and Edwards Mira (EM) valves have an identical mechanical design but different sewing cuffs. The purpose of this retrospective study was to analyze the long-term clinical and echocardiographic outcomes after mitral valve replacement with these two valves in a combined population of patients. METHODS We retrospectively reviewed records of 73 patients who underwent mitral valve replacement using SB (n = 19) or EM (n = 54) valves. Preoperatively, 49 patients (68.1%) were in New York Heart Association (NYHA) functional class III or IV. Concomitant procedures were performed in 52 patients (71.2%). Early and late postoperative echocardiography was performed in 69 and 57 patients, respectively. RESULTS Operative mortality was 4.1%, and early morbidity was 9.6%. Overall patient survival at 9 years was 85.1% +/- 4.8%. Actuarial freedom from valve-related death was 95.4% +/- 2.6% at 9 years. As shown by Doppler echocardiography, the early and late mean transprosthetic pressure gradients were 3.4 +/- 1.4 mmHg and 3.8 +/- 2.1 mmHg, respectively. At the end of follow-up, 98.4% of survivors were in NYHA class I or II. CONCLUSION The Sorin Bicarbon and, Edwards Mira mechanical valves in the mitral position provide satisfactory long-term clinical and echocardiographic performance.
Collapse
Affiliation(s)
- Toshihiro Fukui
- Department of Cardiovascular Surgery, Osaka City University Graduate School of Medicine, 1-4-3 Asahimachi, Abeno-ku, Osaka, Japan.
| | | | | | | | | | | | | |
Collapse
|
8
|
Misawa Y, Saito T, Konishi H, Oki SI, Kaminishi Y, Sakano Y, Morita H, Aizawa K. Clinical experience with the Bicarbon heart valve prosthesis. J Cardiothorac Surg 2007; 2:8. [PMID: 17254363 PMCID: PMC1794238 DOI: 10.1186/1749-8090-2-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2006] [Accepted: 01/25/2007] [Indexed: 12/14/2022] Open
Abstract
Bacground We have previously reported mid-term results of a study, which ended in January 2000, on the Bicarbon valve. The study concluded that the valve showed excellent clinical results, associated with a low incidence of valve-related complications. In the present study, the same patients were prospectively followed for an additional 5 years. Methods Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 ± 11.3 years. The mean follow-up was 6.1 ± 1.9 years with a cumulative follow-up of 616 patient-years. Results There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 21 late deaths (3.4%/patient-year: 5 valve related deaths and 16 valve unrelated deaths). Survival at 8 years was 75.2 ± 7.0% in the AVR group, 76.6 ± 6.2% in the MVR group, and 55.4 ± 16.1% in the DVR group. The linearized incidence of thrombo-embolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 0.65 ± 1.48%, 0.81 ± 1.69%, and 0.16 ± 0.54%/patient-year respectively. No other complications were observed. Conclusion The Bicarbon prosthetic heart valve has shown excellent long-term clinical results, associated with a low incidence of valve-related complications.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Tsutomu Saito
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Hiroaki Konishi
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Shin-ichi Oki
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Yuichiro Kaminishi
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Yasuhito Sakano
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Hideki Morita
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| | - Kei Aizawa
- Division of Cardiovascular Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, JAPAN
| |
Collapse
|
9
|
Badano LP, Zamorano JL, Pavoni D, Tosoratti E, Baldassi M, Zakja E, Gianfagna P, Fioretti PM, Livi U. Clinical and hemodynamic implications of supra-annular implant of biological aortic valves. J Cardiovasc Med (Hagerstown) 2006; 7:524-32. [PMID: 16801814 DOI: 10.2459/01.jcm.0000234771.96324.28] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The use of stented bioprostheses in elderly patients with degenerative aortic stenosis, despite being desirable, raises concerns about the harmful effects of residual obstruction to left ventricular outflow. To overcome this limitation new stented and stentless bioprostheses have been designed for supra-annular implant. However, the actual hemodynamic advantage of supra-annular implant over the intra-annular one remains incompletely understood. This review focuses on the geometry of biological valve prostheses designed for supra-annular implant and its implications for the echocardiographic assessment of valve hemodynamics. Available data about the hemodynamic performance of these valves implanted in the supra-annular position in comparison with the usual intra-annular implant are also reviewed. Other issues related to biological heart valve performance, such as biomaterials, tissue mechanics, durability, and clinical outcome are not addressed in this review.
Collapse
Affiliation(s)
- Luigi P Badano
- Department of Cardiopulmonary Sciences, A.O. S Maria della Misericordia, Udine, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Josa M, Castellá M, Paré C, Bedini JL, Cartañá R, Mestres CA, Pomar JL, Mulet J. Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve. Ann Thorac Surg 2006; 81:1291-6. [PMID: 16564260 DOI: 10.1016/j.athoracsur.2005.09.045] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2005] [Revised: 09/16/2005] [Accepted: 09/21/2005] [Indexed: 10/24/2022]
Abstract
BACKGROUND Normal functioning mechanical heart valve prostheses are designed to have a certain degree of intrinsic structural regurgitation as a washout mechanism to avoid prosthetic thrombosis. However, intrinsic regurgitation leads to blood cell trauma and hemolysis. Information on hemolysis associated with mechanical bileaflet prostheses is scarce. This study evaluated factors influencing hemolysis in 197 Bicarbon mechanical bileaflet prostheses implanted in 164 patients. METHODS Serial office interviews, laboratory studies, and echocardiography evaluations were done in the surviving patients. An assay for measuring lactate dehydrogenase activity was developed, and the presence and severity of subclinical hemolysis was determined using reported criteria and analyzed at 1 and 2 years. RESULTS Hospital mortality was 5.5%. Follow-up was 98.1% complete. No patient had clinically significant or severe subclinical hemolysis. Serum lactate dehydrogenase levels were significantly higher when a paravalvular leak was documented (282 +/- 85 U/L versus 242 +/- 64 U/L; p = 0.0026). Subclinical hemolysis was significantly more frequent after mitral valve (p = 0.001) and double valve replacement (p = 0.001) than after aortic valve replacement, and was unrelated to prosthetic size or to geometric area index, even in those cases with effective orifice area index equal to or less than 0.85 cm2/m2 (p = 0.298). CONCLUSIONS Mild subclinical hemolysis is frequently associated with normal functioning Bicarbon heart valves. Subclinical hemolysis was significantly influenced by valve position but not by valve size or effective orifice area index and remained stable through time. The magnitude of hemolysis in Bicarbon prostheses compared favorably with that reported for other bileaflet heart valve prostheses.
Collapse
Affiliation(s)
- Miguel Josa
- Cardiovascular Service, Hospital Clinic and University of Barcelona, Barcelona, Spain.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Abstract
Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
Collapse
Affiliation(s)
- Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0535, USA.
| | | | | |
Collapse
|
12
|
Driever R, Fuchs S, Meissner M, Schmitz E, Vetter HO. The Edwards MIRAtm Heart Valve Prosthesis:. A 2-Year Study. J Card Surg 2004; 19:226-31. [PMID: 15151649 DOI: 10.1111/j.0886-0440.2004.04060.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND The Edwards MIRA mechanical heart valve is designed to optimize hemodynamics, reduce thrombogenicity, and avoid mechanical failure with a special hinge mechanism. The purpose of the study was to investigate the clinical performance and postoperative hemodynamic results of the first European patients receiving Edwards MIRA mechanical heart valves. METHODS From March 1998 to March 1999 a total of 54 Edwards MIRA valves model numbers 3600 (aortic, n = 44) and 9600 (mitral, n = 10) were implanted in 52 (36 male, 16 female; mean age 61 +/- 10.1 years) consecutive patients undergoing mechanical valve replacement in a prospective study. Follow-up of the patients including physical examination, ECG, blood tests, and Doppler were performed prior to discharge, at 6 months, at 1 year, and at least 2 years postoperatively. RESULTS Through October 2001 a total of 172 follow-up examinations were completed (51 patients at discharge, 46 patients at 6 months, 43 patients at 12 months, 32 patients at 2 years or beyond). All patients were in NYHA class I and II at the 6-month and 2+-year follow-up. All the patients stated an improved quality of life. Hospital mortality was 1.9%. There were no complications related to anticoagulation. Mean international normalized ratio at 6 months was 3.2 (range 1.9 to 4.3); lactate dehydrogenase was slightly increased with 264 +/- 103 U/L on average (normal value 80 to 240 U/L). No signs of valvular dysfunction or paravalvular leakage were observed. Mean pressure gradients were related to valve diameter: after mitral valve replacement (size 27, 29, 31 mm: 4.8, 3.2, 2.1 mmHg); after aortic valve replacement (size 19, 21, 23, 25 mm: 12.1, 13.1, 9.3, 8.2 mmHg). CONCLUSIONS These preliminary data suggest good hemodynamic function and a low rate of valve-related complications of the Edwards-MIRA mechanical prosthesis.
Collapse
Affiliation(s)
- Rudolf Driever
- Department of Cardiothoracic Surgery, Heart Center, University of Witten/Herdecke, Wuppertal, Germany.
| | | | | | | | | |
Collapse
|
13
|
Erdil N, Cetin L, Demirkilic U, Tatar H, Uzun M. Experience of the small size (25 mm) Sorin Bicarbon bileaflet prosthetic valve in patients with small mitral annuli. J Card Surg 2004; 18:532-8. [PMID: 14992105 DOI: 10.1046/j.0886-0440.2003.02065.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Currently, there is a tendency to use large-size prosthetic valves in mitral position in order to achieve better hemodynamic performance. We aimed to evaluate hemodynamic performance of 25 mm prosthetic valves in mitral position. METHODS Between August 1998 and May 2000, a total of 40 patients, 34 women and 6 men (mean age 42 +/- 12 years), underwent mitral valve replacement with 25 mm bileaflet mechanical valve. Preoperative functional capacity was New York Heart Association classes III and IV in 31 patients. Major indication for surgery was severe mitral stenosis in all patients. RESULTS Total hospital mortality was 5% (two patients). Mean follow-up period was 14.7 +/- 4.9 months (2 to 23 months). No thromboembolic event, paravalvular leak, mechanical failure, endocarditis were observed during the follow-up period. Postoperatively 92.5% of the patients were in the functional capacity of New York Heart Association class I. Postoperative echocardiographic observations have given an average pulmonary artery pressure of 29 +/- 2 mmHg, effective orifice area as 2.95 +/- 0.1 cm2, and mean prosthetic gradient as 6.5 +/- 2.7 mmHg. CONCLUSION In short- and mid-term, small-size (25 mm) Sorin mechanical mitral valves had excellent hemodynamic performance in patients with severe mitral stenosis, moderate or serious pulmonary hypertension, and small mitral annuli, whose body surface area was smaller than 1.6 m2.
Collapse
Affiliation(s)
- Nevzat Erdil
- Department of Cardiovascular Surgery, Alkan Hospital, Ankara, Turkey.
| | | | | | | | | |
Collapse
|
14
|
De Carlo M, Milano AD, Nardi C, Mecozzi G, Bortolotti U. Serial Doppler echocardiographic evaluation of small-sized sorin bicarbon prostheses. J Thorac Cardiovasc Surg 2003; 126:337-43. [PMID: 12928629 DOI: 10.1016/s0022-5223(02)73395-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVE The Sorin Bicarbon prosthesis (Sorin Biomedica, Saluggia, Italy) is a bileaflet valve with curved-profile leaflets, a rolling hinge mechanism, and a pyrolytic carbon-coated titanium alloy housing and sewing ring. Although the Sorin Bicarbon prosthesis has been implanted in greater than 80,000 patients, and reference values on the hemodynamic performance of valve prostheses are needed to avoid patient-prosthesis mismatch, few Doppler echocardiographic data are available on the prosthesis in the aortic position. The aim of this study is to provide a detailed echocardiographic evaluation of the hemodynamic performance and regression of left ventricular hypertrophy after aortic valve replacement with the Sorin Bicarbon prosthesis. METHODS The study included 182 patients who received a 21-mm (n = 61) or 23-mm (n = 121) Sorin Bicarbon prosthesis for pure or prevalent aortic stenosis who underwent serial echocardiograms at 3, 6, and 12 months after aortic valve replacement. RESULTS Mean and peak gradients significantly decreased (P <.001) during follow-up to values of 12 +/- 3 and 22 +/- 6 mm Hg for the 21-mm prosthesis and values of 11 +/- 4 and 19 +/- 6 mm Hg for the 23-mm prosthesis at 1 year. Left ventricular mass index showed a 17% decrease to 120 +/- 27 g/m(2) in recipients of the 21-mm prosthesis (P <.001) and a 21% decrease to 123 +/- 29 g/m(2) in recipients of the 23-mm prosthesis (P <.001). A larger prosthesis size was the only predictor of a higher left ventricular mass index regression. Among recipients of the 21-mm prosthesis, body surface area of greater than 1.85 m(2) was associated with a lower regression of left ventricular mass index. The effective orifice area index was 1.00 +/- 0.11 and 1.08 +/- 0.14 cm(2)/m(2) in recipients of the 21-mm and 23-mm prostheses, respectively. CONCLUSIONS Size 21 mm and 23 mm Sorin Bicarbon prostheses show low transprosthetic gradients, with significant reduction of left ventricular mass index during the first postoperative year. The reported effective orifice areas might be useful for aortic valve replacement in patients with a small aortic annulus to avoid patient-prosthesis mismatch.
Collapse
Affiliation(s)
- Marco De Carlo
- Cardiothoracic Department, University of Pisa Medical School, 56124 Pisa, Italy
| | | | | | | | | |
Collapse
|
15
|
Gillinov AM, Blackstone EH, Rodriguez LL. Prosthesis-patient size: measurement and clinical implications. J Thorac Cardiovasc Surg 2003; 126:313-6. [PMID: 12928620 DOI: 10.1016/s0022-5223(02)73223-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
16
|
Misawa Y, Saito T, Konishi H, Oki SI, Kaminishi Y, Tezuka Y, Aizawa K, Takahashi H, Hasegawa N, Kamisawa O, Kato M, Fuse K. Single-center experience with the bicarbon bileaflet prosthetic heart valve in Japan. Artif Organs 2002; 26:856-61. [PMID: 12296925 DOI: 10.1046/j.1525-1594.2002.06987.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
We analyzed midterm results using the Bicarbon valve in a single center. Forty-four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 +/- 11.3 years. The mean follow-up was 1.8 +/- 1.1 years with a cumulative follow-up of 188 patient-years. There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 5 late deaths (2.7% per patient-year: 3 malignancy, 1 cerebral hemorrhage, 1 myocardial infarction). Survival at 3 years was 91 +/- 4% in the AVR group, 92 +/- 5% in the MVR group, and 66 +/- 23% in the DVR group. The linearized incidence of thromboembolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 1.06 +/- 2.34%, 1.60 +/- 2.53%, and 0.53 +/- 2.22% per patient-year, respectively. No other complications were observed. In conclusion, the Bicarbon prosthetic heart valve has shown excellent clinical results associated with a low incidence of valve-related complications.
Collapse
Affiliation(s)
- Yoshio Misawa
- Division of Cardiovascular Surgery, Jichi Medical School, Tochigi, Japan.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Kadir I, Wan IY, Walsh C, Wilde P, Bryan AJ, Angelini GD. Hemodynamic performance of the 21-mm Sorin Bicarbon mechanical aortic prostheses using dobutamine Doppler echocardiography. Ann Thorac Surg 2001; 72:49-53. [PMID: 11465229 DOI: 10.1016/s0003-4975(01)02666-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Small-sized mechanical aortic prostheses are commonly associated with generation of high transvalvular gradients, particularly in patients with large body surface area, and can result in patient-prosthesis mismatch. This study evaluates the hemodynamic performance of 21-mm Sorin Bicarbon bileaflet mechanical prostheses using dobutamine stress echocardiography. METHODS Fourteen patients (7 women; mean age, 63+/-8 years) who had undergone aortic valve replacement with a 21-mm Sorin Bicarbon bileaflet mechanical prosthesis 32.4+/-5.1 months previously were studied. After a resting Doppler echocardiogram, a dobutamine infusion was started at a rate of 5 microg x kg(-1) x min(-1) and increased to 30 microg x kg(-1) x min(-1) at 15-minute intervals. Pulsed- and continuous-wave Doppler echocardiographic studies were performed at rest and at the end of each increment of dobutamine. Both peak and mean velocity and pressure gradient across the prostheses were measured, and effective orifice area, discharge coefficient, and performance index were calculated. RESULTS Dobutamine stress increased heart rate and cardiac output by 83% and 81%, respectively (both p < 0.0001), and mean transvalvular gradient increased from 15.6+/-5.5 mm Hg at rest to 35.4+/-11.9 mm Hg at maximum stress (p < 0.0001). Although the indexed effective orifice area was significantly lower in patients with a larger body surface area, this was not associated with any significant pressure gradient. The performance index of this valve was unchanged throughout the study. Regression analyses demonstrated that the mean transvalvular gradient at maximum stress was independent of all variables except resting gradient (p = 0.05). Body surface area had no association with the changes in cardiac output, transvalvular gradient at maximum stress, and effective orifice area. CONCLUSIONS These data show that the 21-mm Sorin Bicarbon bileaflet mechanical prosthesis offers an excellent hemodynamic performance with full utilization of its available orifice when implanted in the aortic position. The lack of significant transvalvular gradient in patients with a larger body surface area suggests that patient-prosthesis mismatch is highly unlikely when this prosthesis is used.
Collapse
Affiliation(s)
- I Kadir
- Bristol Heart Institute and Department of Clinical Radiology, University of Bristol, United Kingdom
| | | | | | | | | | | |
Collapse
|
18
|
Baur LH, Houdas Y, Peels KH, Braun J, van Straten B, Prat A, Kappetein AP, Wolters-Geldoff M, van der Wall EE, Bruschke AV, Huysmans HA. Stentless bioprostheses have ideal haemodynamics, even in the small aortic root. INTERNATIONAL JOURNAL OF CARDIAC IMAGING 2000; 16:359-64. [PMID: 11215920 DOI: 10.1023/a:1026521211249] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE To determine normal Doppler and 2D gradients and flow characteristics of the Freestyle stentless aortic bioprosthesis related to valve size. BACKGROUND The Freestyle stentless aortic bioprosthesis is one of the newer aortic xenografts. Only limited data are available of the echocardiographic flow characteristics during a mid-term follow-up period of this valve. Therefore valve performance related to valve size was measured during a follow-up period of two years. METHODS 175 consecutive patients with a Freestyle aortic bioprosthesis underwent an echocardiographic and Doppler examination according to a common protocol. Investigations were done within 4 weeks after operation, after 3 to 6 months, and after 1 and 2 years. RESULTS With a valve size from 19 to 27 mm mean gradients decreased from 8.0 +/- 5.1 mmHg at discharge to 5.8 +/- 3.8 mmHg after 3-6 months (p < 0.001). Thereafter gradients remained stable. The performance index, the ratio of the measured effective orifice area in the patient divided by the effective orifice area measured in vitro increased from 69 +/- 20% at discharge to 79 +/- 29% after one, two and three years. Performance index was especially very high in the smaller sized valves with a performance index of 85 +/- 17% for the 21 mm valve. During follow-up mean gradients remained below 10 mmHg even in the 21 mm valve. CONCLUSION Stentless xenografts have ideal haemodynamics, even in the small aortic root.
Collapse
Affiliation(s)
- L H Baur
- Department of Cardiology, Atrium Medical Centre, Heerlen, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Baur LH, Jin XY, Houdas Y, Peels CH, Braun J, Kappetein AP, Prat A, Hazekamp MG, Van Straten BH, Ploeg A, Sieders A, Voogd PJ, Bruschke AV, van der Wall EE, Westaby S, Huysmans HA. Echocardiographic parameters of the freestyle stentless bioprosthesis in aortic position: the European experience. J Am Soc Echocardiogr 1999; 12:729-35. [PMID: 10477417 DOI: 10.1016/s0894-7317(99)70023-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The objective of this study was to determine normal Doppler and 2-dimensional characteristics of the Freestyle stentless aortic bioprosthesis. The Freestyle aortic bioprosthesis is a new type of aortic xenograft, and experience is limited. We therefore determined the normal range of echocardiographic and Doppler examinations of this valve. Three hundred thirty-nine consecutive patients with a Freestyle aortic bioprosthesis underwent an echocardiographic and Doppler examination according to a common protocol. Investigations were done within 4 weeks after operation, after 3 to 6 months, and after 1, 2, and 3 years. With a valve size from 19 to 27 mm, mean gradients decreased from 7.9 +/- 5.1 mm Hg at discharge to 5.5 +/- 3. 8 mm Hg after 3 to 6 months (P <.001). Thereafter, gradients remained stable. Effective orifice area 1 year after implantation was 1.59 +/- 0.58 cm(2) for the 21-mm valves, 1.92 +/- 0.74 cm(2) for the 23-mm valves, 2.03 +/- 0.64 cm(2) for the 25-mm valves, and 2.52 +/- 0.72 cm(2) for the 27-mm valves (P <.001). The performance index, the ratio of the measured effective orifice area in the patient divided by the effective orifice area measured in vitro, increased from 67% +/- 20% at discharge to 82% +/- 29% after 1, 2, and 3 years. Performance index was especially very high in the smaller-sized valves. After implantation with the subcoronary technique or root-inclusion technique, small cavities could be seen between the native aortic root and the Freestyle valve. Doppler values were evaluated for the Freestyle stentless porcine bioprostheses in the aortic root. Gradients appear to be close to those measured in native valves over a time period of 3 years.
Collapse
Affiliation(s)
- L H Baur
- Department of Cardiology, Leiden University Medical Center, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Echocardiographic characteristics of transprosthetic blood peak velocity in the Sorin Bicarbon bileaflet prosthetic heart valve. J Artif Organs 1999. [DOI: 10.1007/bf01235528] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
21
|
Reisner SA, Harpaz D, Skulski R, Borenstein D, Milo S, Meltzer RS. Hemodynamic performance of four mechanical bileaflet prosthetic valves in the mitral position: an echocardiographic study. EUROPEAN JOURNAL OF ULTRASOUND : OFFICIAL JOURNAL OF THE EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY 1998; 8:193-200. [PMID: 9971902 DOI: 10.1016/s0929-8266(98)00076-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
OBJECTIVES The CarboMedics, Duromedics, Sorin Bicarbon and the St. Jude Medical valves are bileaflet mechanical prostheses of modern but different design. Choosing a valve with the best hemodynamic profile is of clinical importance in patients with small ventricles and a small mitral annulus. METHODS The hemodynamic performance of these valves in the mitral position was compared in 76 asymptomatic, ambulatory patients with normally functioning prosthesis and left ventricle, using Doppler echocardiography. Of the 76 patients studied, 22 had the CarboMedics, 16 had the Duromedics, 17 had the Sorin Bicarbon and 21 had the St. Jude prosthesis. The patients ages ranged from 18 to 81 years. There were 44 women and 32 men. The time from implantation to echocardiographic study ranged from 1 to 55 months. RESULTS The echocardiographic study was performed earlier after surgery in the Sorin Bicarbon group. There was no significant difference in women/man ratio, incidence of atrial fibrillation, left ventricular or left atrial diameters between the four groups. The mean prosthesis size was significantly smaller for Sorin Bicarbon and Duromedics valves compared to the CarboMedics and the St. Jude valves (mean+/-SD, 27.2+/-1.3, 27.1+/-1.1 and 30.0+/-1.9 and 30.0+/-2.7 mm, respectively, P<0.001). Despite its smaller size the Sorin Bicarbon valve had significantly larger effective valve area by Doppler compared to the CarboMedics valve (290+/-40 vs 250+/-60 mm2, respectively, P=0.014). The ratio of effective valve area to prosthesis size was significantly larger for the Sorin Bicarbon valve when compared with any other type of prosthesis. CONCLUSIONS (1) The Sorin Bicarbon bileaflet valve offered the best hemodynamic results that may be explained by the valve's large leaflet opening angle and small thickness of the leaflets. (2) Since the Sorin Bicarbon is the newest bileaflet valve, durability of this valve remains uncertain.
Collapse
Affiliation(s)
- S A Reisner
- Department of Cardiology, Ramban and Walfson Medical Center, Faculty of Medicine, Technion-Israel Institute of Technology, 31096, Haifa, Israel
| | | | | | | | | | | |
Collapse
|
22
|
Borman JB, Brands WG, Camilleri L, Cotrufo M, Daenen W, Gandjbakhch I, Infantes C, Khayat A, Laborde F, Pellegrini A, Piwnica A, Reichart B, Sharony R, Walesby R, Warembourg H. Bicarbon valve -- European multicenter clinical evaluation. Eur J Cardiothorac Surg 1998; 13:685-93. [PMID: 9686801 DOI: 10.1016/s1010-7940(98)00074-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
OBJECTIVE Fifteen collaborating centers in eight countries present their pooled experience with the new Bicarbon bileaflet valve. METHODS Between 4/90 and 4/96, 1351 patients, 806 males and 545 females, aged 10 to 83, mean 58.4 +/- 12.4, underwent valve implantation. OPERATIONS aortic valve replacement (AVR), 726; mitral valve replacement (MVR), 475; double valve replacement (DVR), 150. Additional procedures: CABG, 211; TV repair, 64; other, 152. RESULTS Mortality: 67 early (seven valve related) and 56 late (40 valve related). Valve thrombosis: six obstructive, three non-obstructive; embolism: nine major cerebral, 37 other. Major bleeding: 29. Hemolysis: two clinically significant. Non-structural dysfunction: 24 paravalvular leaks, one leaflet interference. No structural failure! Endocarditis: 24. Reoperation 48: 22 non-structural dysfunctions, 14 endocarditis, seven thrombosis and embolism, five other. Estimated 5-year freedom from valve-related deaths is 97.2% for AVR and 92.4% for MVR; 4-year freedom from valve related deaths for DVR is 90.5%. Mean calculated NYHA improvement is 1.24. CONCLUSIONS The Bicarbon mechanical prosthesis is well designed, durable, has good hemodynamic features and an acceptably low incidence of complications.
Collapse
Affiliation(s)
- J B Borman
- Bikur Cholim Hospital, Jerusalem, Israel.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|