1
|
Quinn ARJ, Saxby DJ, Yang F, de Sousa ACC, Pizzolato C. A digital twin framework for robust control of robotic-biological systems. J Biomech 2023; 152:111557. [PMID: 37019066 DOI: 10.1016/j.jbiomech.2023.111557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 03/15/2023] [Accepted: 03/22/2023] [Indexed: 03/28/2023]
Abstract
Medical device regulatory standards are increasingly incorporating computational modelling and simulation to accommodate advanced manufacturing and device personalization. We present a method for robust testing of engineered soft tissue products involving a digital twin paradigm in combination with robotic systems. We developed and validated a digital twin framework for calibrating and controlling robotic-biological systems. A forward dynamics model of the robotic manipulator was developed, calibrated, and validated. After calibration, the accuracy of the digital twin in reproducing the experimental data improved in the time domain for all fourteen tested configurations and improved in frequency domain for nine configurations. We then demonstrated displacement control of a spring in lieu of a soft tissue element in a biological specimen. The simulated experiment matched the physical experiment with 0.09 mm (0.001%) root-mean-square error for a 2.9 mm (5.1%) length change. Finally, we demonstrated kinematic control of a digital twin of the knee through 70-degree passive flexion kinematics. The root-mean-square error was 2.00°, 0.57°, and 1.75° degrees for flexion, adduction, and internal rotations, respectively. The system well controlled novel mechanical elements and generated accurate kinematics in silico for a complex knee model. This calibration method could be applied to other situations where the specimen is poorly represented in the model environment (e.g., human or animal tissues), and the control system could be extended to track internal parameters such as tissue strain (e.g., control knee ligament strain). Further development of this framework can facilitate medical device testing and innovative biomechanics research.
Collapse
Affiliation(s)
- Alastair R J Quinn
- Griffith Centre of Biomedical and Rehabilitation Engineering, Menzies Health Institute Queensland, Griffith University, Australia; Advanced Design and Prototyping Technologies Institute, Griffith University, Australia; School of Health Sciences and Social Work, Griffith University, Australia.
| | - David J Saxby
- Griffith Centre of Biomedical and Rehabilitation Engineering, Menzies Health Institute Queensland, Griffith University, Australia; Advanced Design and Prototyping Technologies Institute, Griffith University, Australia; School of Health Sciences and Social Work, Griffith University, Australia
| | - Fuwen Yang
- School of Engineering and Built Environment, Griffith University, Australia
| | - Ana C C de Sousa
- Griffith Centre of Biomedical and Rehabilitation Engineering, Menzies Health Institute Queensland, Griffith University, Australia; Advanced Design and Prototyping Technologies Institute, Griffith University, Australia; School of Health Sciences and Social Work, Griffith University, Australia
| | - Claudio Pizzolato
- Griffith Centre of Biomedical and Rehabilitation Engineering, Menzies Health Institute Queensland, Griffith University, Australia; Advanced Design and Prototyping Technologies Institute, Griffith University, Australia; School of Health Sciences and Social Work, Griffith University, Australia
| |
Collapse
|
2
|
In search of a gold standard for objective clinical outcome: using dynamic biplane radiography to measure knee kinematics. Knee Surg Sports Traumatol Arthrosc 2022; 30:1499-1501. [PMID: 34853896 DOI: 10.1007/s00167-021-06781-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Accepted: 10/18/2021] [Indexed: 10/19/2022]
|
3
|
Kefala V, Ali AA, Hamilton LD, Mannen EM, Shelburne KB. Effects of Weight-Bearing on Tibiofemoral, Patellofemoral, and Patellar Tendon Kinematics in Older Adults. Front Bioeng Biotechnol 2022; 10:820196. [PMID: 35497367 PMCID: PMC9048742 DOI: 10.3389/fbioe.2022.820196] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 03/08/2022] [Indexed: 11/26/2022] Open
Abstract
Quantification of natural knee kinematics is essential for the assessment of joint function in the diagnosis of pathologies. Combined measurements of tibiofemoral and patellofemoral joint kinematics are necessary because knee pathologies, such as progression of osteoarthritis and patellar instability, are a frequent concern in both articulations. Combined measurement of tibiofemoral and patellofemoral kinematics also enables calculation of important quantities, specifically patellar tendon angle, which partly determines the loading vector at the tibiofemoral joint and patellar tendon moment arm. The goals of this research were to measure the differences in tibiofemoral and patellofemoral kinematics, patellar tendon angle (PTA), and patellar tendon moment arm (PTMA) that occur during non-weight-bearing and weight-bearing activities in older adults. METHODS High-speed stereo radiography was used to measure the kinematics of the tibiofemoral and patellofemoral joints in subjects as they performed seated, non-weight-bearing knee extension and two weight-bearing activities: lunge and chair rise. PTA and PTMA were extracted from the subject's patellofemoral and tibiofemoral kinematics. Kinematics and the root mean square difference (RMSD) between non-weight-bearing and weight-bearing activities were compared across subjects and activities. RESULTS Internal rotation increased with weight-bearing (mean RMSD from knee extension was 4.2 ± 2.4° for lunge and 3.6 ± 1.8° for chair rise), and anterior translation was also greater (mean RMSD from knee extension was 2.2 ± 1.2 mm for lunge and 2.3 ± 1.4 mm for chair rise). Patellar tilt and medial-lateral translation changed from non-weight-bearing to weight-bearing. Changes of the patellar tendon from non-weight-bearing to weight-bearing were significant only for PTMA. CONCLUSIONS While weight-bearing elicited changes in knee kinematics, in most degrees of freedoms, these differences were exceeded by intersubject differences. These results provide comparative kinematics for the evaluation of knee pathology and treatment in older adults.
Collapse
Affiliation(s)
- Vasiliki Kefala
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
| | - Azhar A. Ali
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
- Stryker Orthopedics, Kalamazoo, MI, United States
| | - Landon D. Hamilton
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
| | - Erin M. Mannen
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
- Department of Mechanical and Biomedical Engineering, Boise State University, Boise, ID, United States
| | - Kevin B. Shelburne
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, United States
| |
Collapse
|
4
|
Safari M, Shojaei S, Tehrani P, Karimi A. A patient-specific finite element analysis of the anterior cruciate ligament under different flexion angles. J Back Musculoskelet Rehabil 2021; 33:811-815. [PMID: 31815688 DOI: 10.3233/bmr-191505] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The main responsibility of the anterior cruciate ligament (ACL) is to restore normal knee kinematics and kinetics. Although so far different research has been carried out to measure or quantify the stresses and strains in the ACL experimentally or numerically, there is still a paucity of knowledge in this regard under different flexion angles of the tibiofemoral knee joint. OBJECTIVE Understanding the stresses and strains within the ACL under various loading and boundary conditions may have a key asset for the development of an optimal surgical treatment of ACL injury that can better restore normal knee function. This study aimed to calculate the stresses and strains within the ACL under different flexion angles using a patient-specific finite element (FE) model of the human tibiofemoral knee joint. METHODS A patient-specific FE model of the human tibiofemoral knee joint was established using computed tomography/magnetic resonance imaging data to calculate the stresses and strains in the ACL under different flexion angles of 0, 10, 20, 30, and 45∘. RESULTS Although the role of the flexion angle in the induced stresses and strains of the ACL was insignificant, the highest stress and strain were observed at the flexion angle of 0∘. The concentration of the stresses and strains regardless of the flexion angles were also located at the proximal end of the ACL, where the clinical reports indicated that most ACL tearing occurs there at the femoral insertion site. CONCLUSIONS The results have implications not only for understanding the stresses and strains within the ACL under different flexion angles, but also for providing preliminary data for the biomechanical and medical experts in regard of the injuries which may occur to the ACL at relatively higher flexion angles.
Collapse
Affiliation(s)
- Maedeh Safari
- Department of Biomedical Engineering, Islamic Azad University, Central Tehran Branch, Tehran, Iran
| | - Shahrokh Shojaei
- Department of Biomedical Engineering, Islamic Azad University, Central Tehran Branch, Tehran, Iran
| | - Pedram Tehrani
- Department of Mechanical Engineering, Islamic Azad University, Central Tehran Branch, Tehran, Iran
| | - Alireza Karimi
- Department of Mechanical Engineering, Kyushu University, Nishi-ku, Fukuoka, Japan
| |
Collapse
|
5
|
Badida R, Garcia-Lopez E, Sise C, Moore DC, Crisco JJ. An Approach to Robotic Testing of the Wrist Using Three-Dimensional Imaging and a Hybrid Testing Methodology. J Biomech Eng 2020; 142:064501. [PMID: 31960897 PMCID: PMC7172869 DOI: 10.1115/1.4046050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 01/03/2020] [Indexed: 11/08/2022]
Abstract
Robotic technology is increasingly used for sophisticated in vitro testing designed to understand the subtleties of joint biomechanics. Typically, the joint coordinate systems in these studies are established via palpation and digitization of anatomic landmarks. We are interested in wrist mechanics in which overlying soft tissues and indistinct bony features can introduce considerable variation in landmark localization, leading to descriptions of kinematics and kinetics that may not appropriately align with the bony anatomy. In the wrist, testing is often performed using either load or displacement control with standard material testers. However, these control modes either do not consider all six degrees-of-freedom (DOF) or reflect the nonlinear mechanical properties of the wrist joint. The development of an appropriate protocol to investigate complexities of wrist mechanics would potentially advance our understanding of normal, pathological, and artificial wrist function. In this study, we report a novel methodology for using CT imaging to generate anatomically aligned coordinate systems and a new methodology for robotic testing of wrist. The methodology is demonstrated with the testing of 9 intact cadaver specimens in 24 unique directions of wrist motion to a resultant torque of 2.0 N·m. The mean orientation of the major principal axis of range of motion (ROM) envelope was oriented 12.1 ± 2.7 deg toward ulnar flexion, which was significantly different (p < 0.001) from the anatomical flexion/extension axis. The largest wrist ROM was 98 ± 9.3 deg in the direction of ulnar flexion, 15 deg ulnar from pure flexion, consistent with previous studies [1,2]. Interestingly, the radial and ulnar components of the resultant torque were the most dominant across all directions of wrist motion. The results of this study showed that we can efficiently register anatomical coordinate systems from CT imaging space to robotic test space adaptable to any cadaveric joint experiments and demonstrated a combined load-position strategy for robotic testing of wrist.
Collapse
Affiliation(s)
- Rohit Badida
- Department of Orthopedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Brown University, Providence, RI 02903
| | - Edgar Garcia-Lopez
- Department of Orthopedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Brown University, Providence, RI 02903
| | - Claire Sise
- Department of Biomedical Engineering, Brown University, Providence, RI 02912
| | - Douglas C. Moore
- Department of Orthopedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Brown University, Providence, RI 02903
| | - Joseph J. Crisco
- Department of Biomedical Engineering, Brown University, Providence, RI 02912; Department of Orthopedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Brown University, Providence, RI 02903
| |
Collapse
|
6
|
Markolf K, Yamaguchi K, Matthew J, McAllister D. Effects of tibiofemoral compression on ACL forces and knee kinematics under combined knee loads. J Orthop Res 2019; 37:631-639. [PMID: 30676657 DOI: 10.1002/jor.24233] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Accepted: 01/08/2019] [Indexed: 02/04/2023]
Abstract
Injuries to the anterior cruciate ligament (ACL) can occur during landing from a jump or changing direction during a cutting maneuver. In these instances, the knee is subjected to combined forces and moments as it flexes under tibiofemoral compression force (TCF). We hypothesized that TCF would increase ACL forces and tibiofemoral motions under isolated and combined modes of loading relevant to knee injury. ACL force and knee kinematics were recorded in human cadaveric specimens during knee flexion from 0° to 50° under the following test conditions (alone and in combination): 2 N-m internal tibial torque (IT), 5 N-m valgus moment (VM), and 45N anterior tibial force (AF). Knees were tested with 25N (baseline), 250N, and 500N TCF. ACL force increased with knee flexion during all tests. As the knee was flexed, VM produced a coupled internal tibial rotation, and IT produced a coupled valgus rotation. ACL forces with IT + VM were significantly higher than with IT alone (beyond 10° flexion) or VM alone (at all flexion angles). Increasing the level of TCF above baseline did not significantly change valgus or tibial rotations for any loading condition, but did significantly increase anterior tibial translation (ATT) at all flexion angles and ACL force at flexion angles beyond 5° to 15°. Addition of AF to tests with IT + VM significantly increased ATT and ACL force without significantly altering internal and valgus rotations. The mechanism of high ACL force generation from increased TCF was related to ATT and not internal or valgus rotations of the tibia. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.
Collapse
Affiliation(s)
- Keith Markolf
- UCLA Department of Orthopaedic Surgery, Biomechanics Research Section, UCLA Rehabilitation Center, 1000 Veteran Ave., Room 21-67, Los Angeles, California, 90095-1759
| | - Kent Yamaguchi
- UCLA Department of Orthopaedic Surgery, Biomechanics Research Section, UCLA Rehabilitation Center, 1000 Veteran Ave., Room 21-67, Los Angeles, California, 90095-1759
| | - Justin Matthew
- UCLA Department of Orthopaedic Surgery, Biomechanics Research Section, UCLA Rehabilitation Center, 1000 Veteran Ave., Room 21-67, Los Angeles, California, 90095-1759
| | - David McAllister
- UCLA Department of Orthopaedic Surgery, Biomechanics Research Section, UCLA Rehabilitation Center, 1000 Veteran Ave., Room 21-67, Los Angeles, California, 90095-1759
| |
Collapse
|
7
|
El Daou H, Calder JD, Stephen JM. Development and validation of a robotic system for ankle joint testing. Med Eng Phys 2018; 62:53-57. [PMID: 30344070 DOI: 10.1016/j.medengphy.2018.10.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 07/27/2018] [Accepted: 10/08/2018] [Indexed: 10/28/2022]
Abstract
Ankle sprains are the most common sports injury. Gaining a better understanding of ankle mechanics will help improve current treatments, enabling a better quality of life for patients following surgery. In this paper, the development of a robotic system for ankle joint testing is presented. It is composed of an industrial robot, a universal force/torque sensor and bespoke holders allowing high repositioning of specimens. A specimen preparation protocol that uses optical tracking to register the ankle specimens is used. A registration technique is applied to define and calibrate the task related coordinate system needed to control the joint's degrees of freedom and to simulate standardised, clinical ankle laxity tests. Experiments were carried out at different flexion angles using the robotic platform. Optical tracking was used to record the resulting motion of the tibia for every simulated test. The measurements from the optical tracker and the robot were compared and used to validate the system. These findings showed that the optical tracking measurements validate those from the robot for ankle joint testing with interclass coefficients equal to 0.991, 0.996 and 0.999 for the anterior-posterior translations, internal-external and inversion-eversion rotations.
Collapse
Affiliation(s)
- Hadi El Daou
- Imperial College London, South Kensington Campus, London SW7 2AZ, UK.
| | - James D Calder
- Imperial College London, South Kensington Campus, London SW7 2AZ, UK; Fortius Clinic, London, UK
| | - Joanna M Stephen
- Imperial College London, South Kensington Campus, London SW7 2AZ, UK; Fortius Clinic, London, UK
| |
Collapse
|
8
|
Bates NA, Nesbitt RJ, Shearn JT, Myer GD, Hewett TE. The influence of internal and external tibial rotation offsets on knee joint and ligament biomechanics during simulated athletic tasks. Clin Biomech (Bristol, Avon) 2018; 52:109-116. [PMID: 29425835 PMCID: PMC5835205 DOI: 10.1016/j.clinbiomech.2018.01.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 01/16/2018] [Accepted: 01/22/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Following anterior cruciate ligament injury and subsequent reconstruction transverse plane tibiofemoral rotation becomes underconstrained and overconstrained, respectively. Conflicting reports exist on how rotations influence loading at the knee. This investigation aimed to determine the mechanical effects of internal and external tibial rotation offsets on knee kinematics and ligament strains during in vitro simulations of in vivo recorded kinematics. METHOD A 6-degree-of-freedom robotic manipulator arm was used to articulate 11 cadaveric tibiofemoral joint specimens through simulations of four athletic tasks produced from in vivo recorded kinematics. These simulations were then repeated with 4° tibial rotation offsets applied to the baseline joint orientation. FINDINGS Rotational offsets had a significant effect on peak posterior force for female motion simulations (P < 0.01), peak lateral force for most simulated tasks (P < 0.01), and peak anterior force, internal torque, and flexion torque for sidestep cutting tasks (P ≤ 0.01). Rotational offsets did not exhibit statistically significant effects on peak anterior cruciate ligament strain (P > 0.05) or medial collateral ligament strain (P > 0.05) for any task. INTERPRETATION Transverse plane rotational offsets comparable to those observed in anterior cruciate ligament deficient and reconstructed patients alter knee kinetics without significantly altering anterior cruciate ligament strain. As knee degeneration is attributed to abnormal knee loading profiles, altered transverse plane kinematics may contribute to this. However, altered transverse plane rotations likely play a limited role in anterior cruciate ligament injury risk as physiologic offsets failed to significantly influence anterior cruciate ligament strain during athletic tasks.
Collapse
Affiliation(s)
- Nathaniel A. Bates
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA,Department of Biomedical Engineering and Physiology, Mayo Clinic, Rochester, MN, USA
| | - Rebecca J. Nesbitt
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Jason T. Shearn
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Gregory D. Myer
- Division of Sports Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA,Department of Pediatrics, College of Medicine, University of Cincinnati, Cincinnati, OH, USA,Department of Orthopaedic Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH, USA
| | - Timothy E. Hewett
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA,Department of Biomedical Engineering and Physiology, Mayo Clinic, Rochester, MN, USA,Sports Medicine Center, Mayo Clinic, Rochester, MN, USA,Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
9
|
Bates NA, Nesbitt RJ, Shearn JT, Myer GD, Hewett TE. Knee Abduction Affects Greater Magnitude of Change in ACL and MCL Strains Than Matched Internal Tibial Rotation In Vitro. Clin Orthop Relat Res 2017; 475:2385-2396. [PMID: 28455730 PMCID: PMC5599390 DOI: 10.1007/s11999-017-5367-9] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Anterior cruciate ligament (ACL) injures incur over USD 2 billion in annual medical costs and prevention has become a topic of interest in biomechanics. However, literature conflicts persist over how knee rotations contribute to ACL strain and ligament injury. To maximize the efficacy of ACL injury prevention, the effects of underlying mechanics need to be better understood. QUESTIONS/PURPOSES We applied robotically controlled, in vivo-derived kinematic stimuli to the knee to assess ligament biomechanics in a cadaver model. We asked: (1) Does the application of abduction rotation increase ACL and medial collateral ligament (MCL) strain relative to the normal condition? (2) Does the application of internal tibial rotation impact ACL strain relative to the neutral condition? (3) Does combined abduction and internal tibial rotation increase ligament strain more than either individual contribution? METHODS A six-degree-of-freedom robotic manipulator was used to position 17 cadaveric specimens free from knee pathology outside of low-grade osteoarthritis (age, 47 ± 8 years; 13 males, four females) into orientations that mimic initial contact recorded from in vivo male and female drop vertical jump and sidestep cutting activities. Four-degree rotational perturbations were applied in both directions from the neutral alignment position (creating an 8° range) for each frontal, transverse, and combined planes while ACL and MCL strains were continuously recorded with DVRT strain gauges implanted directly on each ligament. Analysis of variance models with least significant difference post hoc analysis were used to assess differences in ligament strain and joint loading between sex, ligament condition, or motion task and rotation type. RESULTS For the female drop vertical jump simulation in the intact knee, isolated abduction and combined abduction/internal rotational stimuli produced the greatest change in strain from the neutral position as compared with all other stimuli within the ACL (1.5% ± 1.0%, p ≤ 0.035; 1.8% ± 1.3%, p ≤ 0.005) and MCL (1.8% ± 1.0%, p < 0.001; 1.6% ± 1.3%, p < 0.001) compared with all other applied stimuli. There were no differences in mean peak ACL strain between any rotational stimuli (largest mean difference = 2.0%; 95% confidence interval [CI], -0.9% to 5.0%; p = 0.070). These trends were consistent for all four simulated tasks. Peak ACL strain in the intact knee was larger than peak MCL strain for all applied rotational stimuli in the drop vertical jump simulations (smallest mean difference = 2.1%; 95% CI, -0.4% to 4.5%; p = 0.047). CONCLUSIONS Kinematically constrained cadaveric knee models using peak strain as an outcome variable require greater than 4° rotational perturbations to elicit changes in intraarticular ligaments. CLINICAL RELEVANCE Because combined rotations and isolated abduction produced greater change in strain relative to the neutral position for the ACL and MCL than any other rotational stimuli in this cadaver study, hypotheses for in vivo investigations aimed toward injury prevention that focuses on the reduction of frontal plane knee motion should be considered. Furthermore, reduced strain in the MCL versus the ACL may help explain why only 30% of ACL ruptures exhibit concomitant MCL injuries.
Collapse
Affiliation(s)
- Nathaniel A. Bates
- Departments of Orthopedic Surgery and Physiology and Biomedical Engineering, Mayo Clinic, 200 First Street SW, Rochester, MN 55902 USA
| | - Rebecca J. Nesbitt
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH USA
| | - Jason T. Shearn
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH USA
| | - Gregory D. Myer
- Division of Sports Medicine, Cincinnati Children’s Hospital Medical Center, USA; and the Departments of Pediatrics and Orthopedic Surgery, College of Medicine, University of Cincinnati, Cincinnati, OH USA
| | - Timothy E. Hewett
- Departments of Orthopedic Surgery and Physiology and Biomedical Engineering, Mayo Clinic, 200 First Street SW, Rochester, MN 55902 USA ,Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN USA
| |
Collapse
|
10
|
Assessment of pose repeatability and specimen repositioning of a robotic joint testing platform. Med Eng Phys 2017; 47:210-213. [DOI: 10.1016/j.medengphy.2017.06.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 04/16/2017] [Accepted: 06/02/2017] [Indexed: 01/19/2023]
|
11
|
Schliemann B, Lenschow S, Domnick C, Herbort M, Häberli J, Schulze M, Wähnert D, Raschke MJ, Kösters C. Knee joint kinematics after dynamic intraligamentary stabilization: cadaveric study on a novel anterior cruciate ligament repair technique. Knee Surg Sports Traumatol Arthrosc 2017; 25:1184-1190. [PMID: 26239862 DOI: 10.1007/s00167-015-3735-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Accepted: 07/22/2015] [Indexed: 01/12/2023]
Abstract
PURPOSE Dynamic intraligamentary stabilization (DIS) has been introduced for the repair of acute anterior cruciate ligament (ACL) tears as an alternative to delayed reconstruction. The aim of the present study was to compare knee joint kinematics after DIS to those of the ACL-intact and ACL-deficient knee under simulated Lachman/KT-1000 and pivot-shift tests. We hypothesized that DIS provides knee joint kinematics equivalent to an intact ACL. METHODS With the use of a robotic knee simulator, knee kinematics were determined in simulated Lachman/KT-1000 and pivot-shift tests at 0°, 15°, 30°, 60°, and 90° of flexion in eight cadaveric knees under the following conditions: (1) intact ACL, (2) ACL deficiency, (3) DIS with a preload of 60 N, and (4) DIS with a preload of 80 N. Statistical analyses were performed using two-factor repeated-measures analysis of variance. The significance level was set at a p value of <0.05. RESULTS After DIS with a preload of either 60 N or 80 N, the anterior translation was significantly reduced in the simulated Lachman/KT-1000 and pivot-shift tests when compared to the ACL-deficient knee (p < 0.05). No significant differences were observed between the DIS reconstruction with a preload of 80 N and the intact ACL with regard to anterior laxity in either test. However, DIS with a preload of only 60 N was not able to restore knee joint kinematics to that of an intact knee in all degrees of flexion. CONCLUSION DIS with a preload of 80 N restores knee joint kinematics comparable to that of an ACL-intact knee and is therefore capable of providing knee joint stability during ACL healing. DIS therefore provides a new technique for primary ACL repair with superior biomechanical properties in comparison with other techniques that have been described previously, although further clinical studies are required to determine its usefulness in clinical settings.
Collapse
Affiliation(s)
- Benedikt Schliemann
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany.
| | - Simon Lenschow
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| | - Christoph Domnick
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| | - Mirco Herbort
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| | | | - Martin Schulze
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| | - Dirk Wähnert
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| | - Michael J Raschke
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| | - Clemens Kösters
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert-Schweitzer-Campus, Building Waldeyerstraße 1, 48149, Münster, Germany
| |
Collapse
|
12
|
Rahnemai-Azar AA, Arilla FV, Bell KM, Fu FH, Musahl V, Debski RE. Biomechanical evaluation of knee endpoint during anterior tibial loading: Implication for physical exams. Knee 2017; 24:258-263. [PMID: 28188084 DOI: 10.1016/j.knee.2016.11.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 10/29/2016] [Accepted: 11/27/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND Physical exams that apply anterior tibial loads are typically used to evaluate knees with anterior cruciate ligament (ACL) injuries. The amount of anterior tibial translation that occurs during these exams can be difficult to assess due to a "soft" endpoint. Therefore, the objective of this study is to determine the biomechanical characteristics of the endpoint for the intact and ACL deficient knee using quantitative criteria. METHODS Eight porcine knees were tested using a robotic testing system. An 89N anterior tibial load was applied to the intact and ACL deficient knee at 30°, 45°, 60° and 75° of flexion. The stiffness of the toe and linear regions was determined from the load-translation curve. The width of the transition region was defined by the distance between the points where the best-fit lines used to define the stiffness of the toe and linear regions diverged from the load-translation curve. RESULTS Stiffness of the toe and linear regions significantly decreased after transecting the ACL at all flexion angles (71-85% and 38-62%, respectively). Width of the transition region was significantly increased in the ACL deficient knee at all flexion angles (approximately four to five times and four to nine times, respectively). CONCLUSIONS The novel quantitative criteria developed in this study have the potential to be deployed in clinical practice by coupling them with data from knee arthrometers that are commonly used in clinical practice. Thus, additional information from the load-translation curve can be provided to improve the diagnosis of ACL injury.
Collapse
Affiliation(s)
- Ata A Rahnemai-Azar
- Orthopaedic Robotics Laboratory, Department of Orthopaedic Surgery, Department of Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219, USA; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA 15213, USA
| | - Fabio V Arilla
- Orthopaedic Robotics Laboratory, Department of Orthopaedic Surgery, Department of Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219, USA; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA 15213, USA
| | - Kevin M Bell
- Orthopaedic Robotics Laboratory, Department of Orthopaedic Surgery, Department of Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219, USA; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA 15213, USA
| | - Freddie H Fu
- Orthopaedic Robotics Laboratory, Department of Orthopaedic Surgery, Department of Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219, USA; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA 15213, USA
| | - Volker Musahl
- Orthopaedic Robotics Laboratory, Department of Orthopaedic Surgery, Department of Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219, USA; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA 15213, USA; Department of Bioengineering, University of Pittsburgh, 302 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA 15260, USA
| | - Richard E Debski
- Orthopaedic Robotics Laboratory, Department of Orthopaedic Surgery, Department of Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219, USA; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA 15213, USA; Department of Bioengineering, University of Pittsburgh, 302 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA 15260, USA.
| |
Collapse
|
13
|
Debski RE, Yamakawa S, Musahl V, Fujie H. Use of Robotic Manipulators to Study Diarthrodial Joint Function. J Biomech Eng 2017; 139:2597610. [PMID: 28056127 DOI: 10.1115/1.4035644] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2016] [Indexed: 01/13/2023]
Abstract
Diarthrodial joint function is mediated by a complex interaction between bones, ligaments, capsules, articular cartilage, and muscles. To gain a better understanding of injury mechanisms and to improve surgical procedures, an improved understanding of the structure and function of diarthrodial joints needs to be obtained. Thus, robotic testing systems have been developed to measure the resulting kinematics of diarthrodial joints as well as the in situ forces in ligaments and their replacement grafts in response to external loading conditions. These six degrees-of-freedom (DOF) testing systems can be controlled in either position or force modes to simulate physiological loading conditions or clinical exams. Recent advances allow kinematic, in situ force, and strain data to be measured continuously throughout the range of joint motion using velocity-impedance control, and in vivo kinematic data to be reproduced on cadaveric specimens to determine in situ forces during physiologic motions. The principle of superposition can also be used to determine the in situ forces carried by capsular tissue in the longitudinal direction after separation from the rest of the capsule as well as the interaction forces with the surrounding tissue. Finally, robotic testing systems can be used to simulate soft tissue injury mechanisms, and computational models can be validated using the kinematic and force data to help predict in vivo stresses and strains present in these tissues. The goal of these analyses is to help improve surgical repair procedures and postoperative rehabilitation protocols. In the future, more information is needed regarding the complex in vivo loads applied to diarthrodial joints during clinical exams and activities of daily living to serve as input to the robotic testing systems. Improving the capability to accurately reproduce in vivo kinematics with robotic testing systems should also be examined.
Collapse
Affiliation(s)
- Richard E Debski
- Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219 e-mail:
| | - Satoshi Yamakawa
- Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan
| | - Volker Musahl
- Orthopaedic Robotics Laboratory, Departments of Orthopaedic Surgery and Bioengineering, University of Pittsburgh, 408 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219
| | - Hiromichi Fujie
- Tokyo Metropolitan University, 6-6 Asahigaoka, Hino, Tokyo 191-0065, Japan
| |
Collapse
|
14
|
Relationship between increased in vivo meniscal loads and abnormal tibiofemoral surface alignment in ACL deficient sheep is varied. J Biomech 2016; 49:3824-3832. [DOI: 10.1016/j.jbiomech.2016.10.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 10/01/2016] [Accepted: 10/11/2016] [Indexed: 01/14/2023]
|
15
|
Mechanical role of the posterior column components in the cervical spine. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2016; 25:2129-38. [DOI: 10.1007/s00586-016-4541-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2015] [Revised: 03/18/2016] [Accepted: 03/19/2016] [Indexed: 10/22/2022]
|
16
|
Rosvold JM, Atarod M, Heard BJ, O'Brien EJ, Frank CB, Shrive NG. Ligament and meniscus loading in the ovine stifle joint during normal gait. Knee 2016; 23:70-7. [PMID: 26765863 DOI: 10.1016/j.knee.2015.09.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Revised: 08/17/2015] [Accepted: 09/22/2015] [Indexed: 02/02/2023]
Abstract
BACKGROUND The ovine stifle joint is an ideal preclinical model to study knee joint biomechanics. Knowledge of the ovine ligamentous and meniscal loading during normal gait is currently limited. METHODS The in vivo kinematics of the ovine stifle joint (N=4) were measured during "normal" gait using a highly accurate instrumented spatial linkage (ISL, 0.3±0.2mm). These motions were reproduced in vitro using a unique robotic testing platform and the loads carried by the anterior/posterior cruciate ligaments (ACL/PCL), medial/lateral collateral ligaments (MCL/LCL), and medial/lateral menisci (MM/LM) during gait were determined. RESULTS Considerable inter-subject variability in tissue loads was observed. The load in the ACL was near zero at hoof-strike (0% gait) and reached a peak (100 to 300N) during early-stance (~10% gait). The PCL reached a peak load (200 to 500N) just after hoof-strike (~5% gait) and was mostly unloaded throughout the remainder of stance. Load in the MCL was substantially lower than the cruciate ligaments, reaching a maximum of 50 to 100N near the beginning of stance. The LCL carried a negligible amount of load through the entire gait cycle. There was also a major contribution of the MM and LM to load transfer from the femur to the tibia during normal gait. The total meniscal load reached a maximum average between 350 and 550N during gait. CONCLUSION Knowledge of joint function during normal motion is essential for understanding normal and pathologic joint states. The considerable variability in the magnitudes and patterns of tissue loads among animals simulates clinical variability in humans. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Joshua M Rosvold
- Department of Civil Engineering, Faculty of Engineering, University of Calgary, Calgary, AB, Canada.
| | - Mohammad Atarod
- McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
| | - Bryan J Heard
- McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
| | - Etienne J O'Brien
- McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
| | - Cyril B Frank
- McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
| | - Nigel G Shrive
- McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, AB, Canada.
| |
Collapse
|
17
|
Schliemann B, Treder M, Schulze M, Müller V, Vasta S, Zampogna B, Herbort M, Kösters C, Raschke MJ, Lenschow S. Influence of Different Tibial Fixation Techniques on Initial Stability in Single-Stage Anterior Cruciate Ligament Revision With Confluent Tibial Tunnels: A Biomechanical Laboratory Study. Arthroscopy 2016; 32:78-89. [PMID: 26372523 DOI: 10.1016/j.arthro.2015.06.044] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2014] [Revised: 06/21/2015] [Accepted: 06/30/2015] [Indexed: 02/02/2023]
Abstract
PURPOSE To kinematically and biomechanically compare 4 different types of tibial tunnel management in single-stage anterior cruciate ligament (ACL) revision reconstruction with the control: primary ACL reconstruction using a robotic-based knee testing setup. METHODS Porcine knees and flexor tendons were used. One hundred specimens were randomly assigned to 5 testing groups: (1) open tibial tunnel, (2) bone plug technique, (3) biodegradable interference screw, (4) dilatation technique, and (5) primary ACL reconstruction. A robotic/universal force-moment sensor testing system was used to simulate the KT-1000 (MEDmetric, San Diego, CA) and pivot-shift tests. Cyclic loading and load-to-failure testing were performed. RESULTS Anterior tibial translation increased significantly with all of the techniques compared with the intact ACL (P < .05). In the simulated KT-1000 test, groups 2 and 3 achieved results equal to those of primary ACL reconstruction (P > .05). The open tunnel and dilated tunnel techniques showed significantly greater anterior tibial translation (P < .05). The results of the simulated pivot-shift test were in accordance with those of the KT-1000 test. No significant differences could be observed regarding stiffness or maximum load to failure. However, elongation was significantly lower in the primary ACL reconstruction group compared with groups 1 and 3 (P = .02 and P = .03, respectively). CONCLUSIONS Filling an incomplete and incorrect tibial tunnel with a press-fit bone plug or a biodegradable interference screw in a standardized laboratory situation provided initial biomechanical properties and knee stability comparable with those of primary ACL reconstruction. In contrast, the dilatation technique or leaving the malplaced tunnel open did not restore knee kinematics adequately in this model. Backup extracortical fixation should be considered because the load to failure depends on the extracortical fixation when an undersized interference screw is used for aperture fixation. CLINICAL RELEVANCE Our biomechanical results could help orthopaedic surgeons to optimize the results of primary ACL revision with incomplete, incorrect tunnel placement.
Collapse
Affiliation(s)
- Benedikt Schliemann
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Maximilian Treder
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Martin Schulze
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Viktoria Müller
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Sebastiano Vasta
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Rome, Italy
| | - Biaggio Zampogna
- Department of Orthopaedic and Trauma Surgery, Campus Bio-Medico University, Rome, Italy
| | - Mirco Herbort
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Clemens Kösters
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Michael J Raschke
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany
| | - Simon Lenschow
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
| |
Collapse
|
18
|
Bell KM, Arilla FV, Rahnemai-Azar AA, Fu FH, Musahl V, Debski RE. Novel technique for evaluation of knee function continuously through the range of flexion. J Biomech 2015; 48:3728-31. [DOI: 10.1016/j.jbiomech.2015.08.019] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Revised: 08/13/2015] [Accepted: 08/14/2015] [Indexed: 11/28/2022]
|
19
|
Li H, Pei BQ, Yang JC, Hai Y, Li DY, Wu SQ. Load rate of facet joints at the adjacent segment increased after fusion. Chin Med J (Engl) 2015; 128:1042-6. [PMID: 25881597 PMCID: PMC4832943 DOI: 10.4103/0366-6999.155080] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Background: The cause of the adjacent segment degeneration (ASD) after fusion remains unknown. It is reported that adjacent facet joint stresses increase after anterior cervical discectomy and fusion. This increase of stress rate may lead to tissue injury. Thus far, the load rate of the adjacent segment facet joint after fusion remains unclear. Methods: Six C2–C7 cadaveric spine specimens were loaded under four motion modes: Flexion, extension, rotation, and lateral bending, with a pure moment using a 6° robot arm combined with an optical motion analysis system. The Tecscan pressure test system was used for testing facet joint pressure. Results: The contact mode of the facet joints and distributions of the force center during different motions were recorded. The adjacent segment facet joint forces increased faster after fusion, compared with intact conditions. While the magnitude of pressures increased, there was no difference in distribution modes before and after fusion. No pressures were detected during flexion. The average growth velocity during extension was the fastest and was significantly faster than lateral bending. Conclusions: One of the reasons for cartilage injury was the increasing stress rate of loading. This implies that ASD after fusion may be related to habitual movement before and after fusion. More and faster extension is disadvantageous for the facet joints and should be reduced as much as possible.
Collapse
Affiliation(s)
| | | | - Jin-Cai Yang
- Department of Orthopedics, Beijing Chao-Yang Hospital, Beijing 100020, China
| | | | | | | |
Collapse
|
20
|
Atarod M, Rosvold JM, Frank CB, Shrive NG. A Novel Testing Platform for Assessing Knee Joint Mechanics: A Parallel Robotic System Combined with an Instrumented Spatial Linkage. Ann Biomed Eng 2014; 42:1121-32. [DOI: 10.1007/s10439-014-0985-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2013] [Accepted: 02/05/2014] [Indexed: 10/25/2022]
|
21
|
Herbort M, Tecklenburg K, Zantop T, Raschke MJ, Hoser C, Schulze M, Petersen W, Fink C. Single-bundle anterior cruciate ligament reconstruction: a biomechanical cadaveric study of a rectangular quadriceps and bone--patellar tendon--bone graft configuration versus a round hamstring graft. Arthroscopy 2013; 29:1981-90. [PMID: 24140140 DOI: 10.1016/j.arthro.2013.08.030] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 08/25/2013] [Accepted: 08/26/2013] [Indexed: 02/02/2023]
Abstract
PURPOSE The purposes of this study were to investigate anterior tibial translation under loading conditions after single-bundle (SB) anterior cruciate ligament (ACL) reconstruction using a rectangular tunnel placement strategy with quadriceps and bone--patellar tendon--bone (BPTB) graft and to compare these data with a SB hamstring reconstruction with a round tunnel design. METHODS In 9 human cadaveric knees, the knee kinematics were examined with robotic/universal force-moment sensor testing. Within the same specimen, the knee kinematics under simulated pivot-shift and KT-1000 arthrometer (MEDmetric, San Diego, CA) testing were determined at 0°, 15°, 30°, 60°, and 90° of flexion under different conditions: intact knee, ACL-deficient knee, and SB ACL-reconstructed knee. For the SB ACL-reconstructed knee, 3 different SB reconstruction techniques were used: a rectangular tunnel strategy (9 × 5 mm) with quadriceps graft, a rectangular tunnel strategy with BPTB graft, and a round tunnel strategy (7 mm) with hamstring graft. RESULTS In a simulated Lachman test, a statistically significant difference was found at 0° and 15° of knee flexion between the rectangular reconstruction with quadriceps graft (5.1 ± 1.2 mm and 8.3 ± 2 mm, respectively) or BPTB graft (5.3 ± 1.5 mm and 8 ± 1.9 mm, respectively) and the reconstruction using hamstring graft (7.2 ± 1.4 mm and 12 ± 1.8 mm, respectively) (P = .032 and P = .033, respectively, at 0°; P = .023 and P = .02, respectively, at 15°). On the simulated pivot-shift test at 0° and 15°, rectangular ACL reconstruction with quadriceps graft (3.9 ± 2.1 mm and 6.5 ± 1.7 mm, respectively) or BPTB graft (4.2 ± 1.8 mm and 6.7 ± 1.7 mm, respectively) showed a significantly lower anterior tibial translation when compared with round tunnel reconstruction (5.5 ± 2.1 mm and 7.9 ± 1.9 mm, respectively) (P = .03 and P = .041, respectively, at 0°; P = .042 and P = .046, respectively, at 15°). CONCLUSIONS Under simulated Lachman testing and pivot-shift testing, a reconstruction technique using a rectangular tunnel results in significantly lower anterior tibial translation at 0° and 15° of flexion in comparison to knees reconstructed with a hamstring SB graft using a round tunnel strategy. CLINICAL RELEVANCE ACL reconstruction with a rectangular tunnel and BPTB and quadriceps tendon might result in better anterior knee stability at low flexion angles than ACL reconstruction with hamstring SB graft and a round tunnel in the clinical setting.
Collapse
Affiliation(s)
- Mirco Herbort
- Department of Trauma-, Hand- and Reconstructive Surgery, Westfaelische Wilhelms-University Muenster, Münster, Germany
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Nguyen DT, Geel J, Schulze M, Raschke MJ, Woo SLY, van Dijk CN, Blankevoort L. Healing of the goat anterior cruciate ligament after a new suture repair technique and bioscaffold treatment. Tissue Eng Part A 2013; 19:2292-9. [PMID: 23725556 DOI: 10.1089/ten.tea.2012.0535] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
Abstract
Primary suture repair of the anterior cruciate ligament (ACL) has been used clinically in an attempt to heal the ruptured ACL. The results, however, were not satisfactory, which in retrospect can be attributed to the used suturing technique and the suboptimal healing conditions. These constraining conditions can be improved by introducing a new suturing technique and by using small intestinal submucosa (SIS) as a bioscaffold. It is hypothesized that the suturing technique keep the torn ends together and that SIS enhance and promote the healing of the ACL. The goat was used as the study model. In the Suture group, the left ACL was transected and suture repaired with a new locking suture repair technique (n=5) allowing approximation and fixation under tension. The Suture-SIS group underwent the same procedure with the addition of SIS (n=5). The right ACL served as control. After 12 weeks of healing, anterior-posterior translation and in situ force of the healing ACL were measured, followed by the measurement of the cross-sectional area and structural stiffness. Routine histology was performed on tissue samples. Gross morphology showed that the healing ACL was continuous with collagenous tissue in both groups. The cross-sectional area of the Suture and the Suture-SIS group was 35% and 50% of the intact control, respectively. The anterior-posterior translations at different flexion angles were statistically not different between the Suture group and the Suture-SIS group. Only the in situ force at 30° in the Suture-SIS group was higher than in the Suture group. Tensile tests showed that the stiffness for the Suture group was not different from the Suture-SIS group (31.1±8.1 N/mm vs. 41.9±18.0 N/mm [p>0.05]). Histology showed longitudinally aligned collagen fibers from origo to insertion. More fibroblasts were present in the healing tissue than in the control intact tissue. The study demonstrated the proof of concept of ACL repair in a goat model with a new suture technique and SIS. The mechanical outcome is not worse than previously reported for ACL reconstruction. In conclusion, the approach of using a new suture technique, with or without a bioscaffold to heal the ACL is promising.
Collapse
Affiliation(s)
- D Tan Nguyen
- Department of Orthopedic Surgery, Orthopaedic Research Center Amsterdam, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
23
|
Kelly BP, DiAngelo DJ. A Multiaxis Programmable Robot for the Study of Multibody Spine Biomechanics Using a Real-Time Trajectory Path Modification Force and Displacement Control Strategy. J Med Device 2013. [DOI: 10.1115/1.4024645] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Robotic testing offers potential advantages over conventional methods including coordinated control of multiple degrees of freedom (DOF) and enhanced fidelity that to date have not been fully utilized. Previous robotic efforts in spine biomechanics have largely been limited to pure displacement control methods and slow quasi-static hybrid control approaches incorporating only one motion segment unit (MSU). The ability to program and selectively direct single or multibody spinal end loads in real-time would represent a significant step forward in the application of robotic testing methods. The current paper describes the development of a custom programmable robotic testing system and application of a novel force control algorithm. A custom robotic testing system with a single 4 DOF serial manipulator was fabricated and assembled. Feedback via position encoders and a six-axis load sensor were established to develop, program, and evaluate control capabilities. A calibration correction scheme was employed to account for changes in load sensor orientation and determination of spinal loads. A real-time force control algorithm was implemented that employed a real-time trajectory path modification feature of the controller. Pilot tests applied 3 Nm pure bending moments to a human cadaveric C2–T1 specimen in flexion and extension to assess the ability to control spinal end loads, and to compare the resulting motion response to previously published data. Stable accurate position control was achieved to within ±2 times the encoder resolution for each axis. Stable control of spinal end body forces was maintained to within a maximum error of 6.3 N in flexion. Sagittal flexibility data recorded from rostral and caudally placed six-axis load sensors were in good agreement, indicating a pure moment loading condition. Individual MSU rotations were consistent with previously reported data from nonrobotic protocols. The force control algorithm required 5–10 path iterations before converging to programmed end body forces within a targeted tolerance. Commercially available components were integrated to create a fully programmable custom 4 DOF gantry robot. Individual actuator performance was assessed. A real-time force control algorithm based on trajectory path modification was developed and implemented. Within a reasonable number of programmed path iterations, good control of spinal end body forces and moments, as well as a motion response consistent with previous reported data, were obtained throughout a full physiologic flexion-extension range of motion in the human subaxial cervical spine.
Collapse
Affiliation(s)
| | - Denis J. DiAngelo
- Department of Orthopedic Surgery and Biomedical Engineering, The University of Tennessee Health Science Center, 956 Court Avenue, Suite E226, Memphis, TN 38163
| |
Collapse
|
24
|
Design and validation of a novel Cartesian biomechanical testing system with coordinated 6DOF real-time load control: application to the lumbar spine (L1–S, L4–L5). J Biomech 2013; 46:1948-54. [DOI: 10.1016/j.jbiomech.2013.05.008] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Revised: 05/08/2013] [Accepted: 05/12/2013] [Indexed: 11/19/2022]
|
25
|
Elkinson I, Giles JW, Faber KJ, Boons HW, Ferreira LM, Johnson JA, Athwal GS. The effect of the remplissage procedure on shoulder stability and range of motion: an in vitro biomechanical assessment. J Bone Joint Surg Am 2012; 94:1003-12. [PMID: 22637206 DOI: 10.2106/jbjs.j.01956] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The remplissage procedure may be performed as an adjunct to Bankart repair to treat recurrent glenohumeral dislocation associated with an engaging Hill-Sachs humeral head defect. The purpose of this in vitro biomechanical study was to examine the effects of the remplissage procedure on glenohumeral joint motion and stability. METHODS Cadaveric shoulders (n = 8) were mounted on a biomechanical testing apparatus that applies simulated loads to the rotator cuff and the anterior, middle, and posterior heads of the deltoid muscle. Testing was performed with the shoulder intact, after creation of the Bankart lesion, and after repair of the Bankart lesion. In addition, testing was performed after Bankart repair with and without remplissage in shoulders with 15% and 30% Hill-Sachs defects. Shoulder motion and glenohumeral translation were recorded with an optical tracking system. Outcomes measured included stability (joint stiffness and defect engagement) and internal-external glenohumeral rotational motion in adduction and in 90° of composite shoulder abduction. RESULTS In specimens with a 15% Hill-Sachs defect, Bankart repair combined with remplissage resulted in a significant reduction in internal-external range of motion in adduction (15.1° ± 11.1°, p = 0.039), but not in abduction (7.7° ± 9.9, p = 0.38), compared with the intact condition. In specimens with a 30% Hill-Sachs defect, repair that included remplissage also significantly reduced internal-external range of motion in adduction (14.5° ± 11.3°, p = 0.049) but not in abduction (6.2° ± 9.3°, p = 0.60). In specimens with a 15% Hill-Sachs defect, addition of remplissage significantly increased joint stiffness compared with isolated Bankart repair (p = 0.038), with the stiffness trending toward surpassing the level in the intact condition (p = 0.060). In specimens with a 30% Hill-Sachs defect, addition of remplissage restored joint stiffness to approximately normal (p = 0.41 compared with the intact condition). All of the specimens with a 30% Hill-Sachs defect engaged and dislocated after Bankart repair alone. The addition of remplissage was effective in preventing engagement and dislocation in all specimens. None of the specimens with a 15% Hill-Sachs defect engaged or dislocated after Bankart repair. CONCLUSIONS In this experimental model, addition of remplissage provided little additional benefit to a Bankart repair in specimens with a 15% Hill-Sachs defect, and it also reduced specific shoulder motions. However, Bankart repair alone was ineffective in preventing engagement and recurrent dislocation in specimens with a 30% Hill-Sachs defect. The addition of remplissage to the Bankart repair in these specimens prevented engagement and enhanced stability, although at the expense of some reduction in shoulder motion.
Collapse
Affiliation(s)
- Ilia Elkinson
- H.U.L.C. Bioengineering Research Laboratory, University of Western Ontario, London, Ontario, Canada
| | | | | | | | | | | | | |
Collapse
|
26
|
Rosvold JM, Darcy SP, Peterson RC, Achari Y, Corr DT, Marchuk LL, Frank CB, Shrive NG, Rosvold JM, Darcy SP, Peterson RC, Achari Y, Corr DT, Marchuk LL, Frank CB, Shrive NG. Technical Issues in Using Robots to Reproduce Joint Specific Gait. J Biomech Eng 2011; 133:054501. [DOI: 10.1115/1.4003665] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Reproduction of the in vivo motions of joints has become possible with improvements in robot technology and in vivo measuring techniques. A motion analysis system has been used to measure the motions of the tibia and femur of the ovine stifle joint during normal gait. These in vivo motions are then reproduced with a parallel robot. To ensure that the motion of the joint is accurately reproduced and that the resulting data are reliable, the testing frame, the data acquisition system, and the effects of limitations of the testing platform need to be considered. Of the latter, the stiffness of the robot and the ability of the control system to process sequential points on the path of motion in a timely fashion for repeatable path accuracy are of particular importance. Use of the system developed will lead to a better understanding of the mechanical environment of joints and ligaments in vivo.
Collapse
Affiliation(s)
- J. M. Rosvold
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - S. P. Darcy
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - R. C. Peterson
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - Y. Achari
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - D. T. Corr
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - L. L. Marchuk
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - C. B. Frank
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - N. G. Shrive
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - Joshua M. Rosvold
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - Shon P. Darcy
- Technical Solutions Group, QinetiQ North America, 350 Second Avenue, Waltham, MA 02451; Project Engineer at Foster-Miller, Inc., 350 Second Avenue, Waltham, MA 02451
| | | | - Yamini Achari
- Department of Surgery, University of Calgary, c/o Joint Injury and Arthritis Research Group, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - David T. Corr
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY 12180-3590
| | - Linda L. Marchuk
- Department of Surgery, University of Calgary, c/o Joint Injury and Arthritis Research Group, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - Cyril B. Frank
- Department of Surgery, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| | - Nigel G. Shrive
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health 3330, Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
| |
Collapse
|
27
|
Herbort M, Lenschow S, Fu FH, Petersen W, Zantop T. ACL mismatch reconstructions: influence of different tunnel placement strategies in single-bundle ACL reconstructions on the knee kinematics. Knee Surg Sports Traumatol Arthrosc 2010; 18:1551-8. [PMID: 20461359 DOI: 10.1007/s00167-010-1163-8] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2010] [Accepted: 04/26/2010] [Indexed: 12/29/2022]
Abstract
To evaluate the influence of tibial and femoral tunnel position in ACL reconstruction on knee kinematics, we compared ACL reconstruction with a tibial and femoral tunnel in anteromedial (AM-AM reconstruction) and in posterolateral footprint (PL-PL reconstruction) with a reconstruction technique with tibial posterolateral and femoral anteromedial tunnel placement (PL-AM reconstruction). In 9 fresh-frozen human cadaveric knees, the knee kinematics under simulated Lachman (134 N anterior tibial load) and a simulated pivot shift test (10 N/m valgus and 4 N/m internal tibial torque) were determined at 0°, 30°, 60°, and 90° of flexion. Kinematics were recorded for intact, ACL-deficient, and single-bundle ACL reconstructed knees using three different reconstruction strategies in randomized order: (1) PL-AM, (2) AM-AM and (3) PL-PL reconstructions. Under simulated Lachman test, single-bundle PL-AM reconstruction and PL-PL reconstructions both showed significantly increased anterior tibial translation (ATT) at 60° and 90° when compared to the intact knee. At all flexion angles, AM-AM reconstruction did not show any statistical significant differences in ATT compared to the intact knee. Under simulated pivot shift, PL-AM reconstruction resulted in significantly higher ATT at 0°, 30°, and 60° knee flexion and AM-AM reconstructions showed significantly higher ATT at 30° compared to the intact knee. PL-PL reconstructions did not show any significant differences to the intact knee. AM-AM reconstructions restore the intact knee kinematics more closely when compared to a PL-AM technique resembling a transtibial approach. PL-PL reconstructions showed increased ATT at higher flexion angles, however, secured the rotational stability at all flexion angles. Due to the independent tibial and femoral tunnel location, a medial portal technique may be superior to a transtibial approach.
Collapse
Affiliation(s)
- Mirco Herbort
- Department of Trauma, Hand and Reconstructive Surgery, Weatfaelian Wilhelms University Muenster, Waldeyer Strasse 1, Muenster, Germany.
| | | | | | | | | |
Collapse
|
28
|
Drury NJ, Ellis BJ, Weiss JA, McMahon PJ, Debski RE. The Impact of Glenoid Labrum Thickness and Modulus on Labrum and Glenohumeral Capsule Function. J Biomech Eng 2010; 132:121003. [DOI: 10.1115/1.4002622] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The glenoid labrum is an integral component of the glenohumeral capsule’s insertion into the glenoid, and changes in labrum geometry and mechanical properties may lead to the development of glenohumeral joint pathology. The objective of this research was to determine the effect that changes in labrum thickness and modulus have on strains in the labrum and glenohumeral capsule during a simulated physical examination for anterior instability. A labrum was incorporated into a validated, subject-specific finite element model of the glenohumeral joint, and experimental kinematics were applied simulating application of an anterior load at 0 deg, 30 deg, and 60 deg of external rotation and 60 deg of glenohumeral abduction. The radial thickness of the labrum was varied to simulate thinning tissue, and the tensile modulus of the labrum was varied to simulate degenerating tissue. At 60 deg of external rotation, a thinning labrum increased the average and peak strains in the labrum, particularly in the labrum regions of the axillary pouch (increased 10.5% average strain) and anterior band (increased 7.5% average strain). These results suggest a cause-and-effect relationship between age-related decreases in labrum thickness and increases in labrum pathology. A degenerating labrum also increased the average and peak strains in the labrum, particularly in the labrum regions of the axillary pouch (increased 15.5% strain) and anterior band (increased 10.4% strain). This supports the concept that age-related labrum pathology may result from tissue degeneration. This work suggests that a shift in capsule reparative techniques may be needed in order to include the labrum, especially as activity levels in the aging population continue to increase. In the future validated, finite element models of the glenohumeral joint can be used to explore the efficacy of new repair techniques for glenoid labrum pathology.
Collapse
Affiliation(s)
- Nicholas J. Drury
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219
| | - Benjamin J. Ellis
- Department of Bioengineering, University of Utah, Salt Lake City, UT 84112
| | - Jeffrey A. Weiss
- Department of Bioengineering, University of Utah, Salt Lake City, UT 84112
| | - Patrick J. McMahon
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219
| | - Richard E. Debski
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219
| |
Collapse
|
29
|
Identification of spinal tissues loaded by manual therapy: a robot-based serial dissection technique applied in porcine motion segments. Spine (Phila Pa 1976) 2010; 35:1983-90. [PMID: 20881661 PMCID: PMC2958225 DOI: 10.1097/brs.0b013e3181ddd0a3] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN Serial dissection of porcine motion segments during robotic control of vertebral kinematics. OBJECTIVE To identify which spinal tissues are loaded in response to manual therapy (manipulation and mobilization) and to what magnitude. SUMMARY OF BACKGROUND DATA Various theoretical constructs attempt to explain how manual therapies load specific spinal tissues. By using a parallel robot to control vertebral kinematics during serial dissection, it is possible to quantify the loads experienced by discrete spinal tissues undergoing common therapeutic procedures such as manual therapy. METHODS In 9 porcine cadavers, manual therapy was provided to L3 and the kinematic response of L3-L4 recorded. The exact kinematic trajectory experienced by L3-L4 in response to manual therapy was then replayed to the isolated segment by a parallel robot equipped with a 6-axis load cell. Discrete spinal tissues were then removed and the kinematic pathway replayed. The change in forces and moments following tissue removal were considered to be those applied to that specific tissue by manual therapy. RESULTS In this study, both manual therapies affected spinal tissues. The intervertebral disc experienced the greatest forces and moments arising from both manipulation and mobilization. CONCLUSION This study is the first to identify which tissues are loaded in response to manual therapy. The observation that manual therapy loads some tissues to a much greater magnitude than others offers a possible explanation for its modest treatment effect; only conditions involving these tissues may be influenced by manual therapy. Future studies are planned to determine if manual therapy can be altered to target (or avoid) specific spinal tissues.
Collapse
|
30
|
Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles. Med Biol Eng Comput 2010; 48:1077-85. [DOI: 10.1007/s11517-010-0653-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2009] [Accepted: 06/12/2010] [Indexed: 01/14/2023]
|
31
|
Wu C, Noorani S, Vercillo F, Woo SLY. Tension patterns of the anteromedial and posterolateral grafts in a double-bundle anterior cruciate ligament reconstruction. J Orthop Res 2009; 27:879-84. [PMID: 19117065 PMCID: PMC2764331 DOI: 10.1002/jor.20822] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The two functional bundles of the anterior cruciate ligament (ACL), namely, the anteromedial (AM) and posterolateral (PL) bundles, must work in concert to control displacement of the tibia relative to the femur for complex motions. Thus, the replacement graft(s) for a torn ACL should possess similar tension patterns. The objective of the study was to examine whether a double-bundle ACL reconstruction with the semitendinosus-gracilis autografts could replicate the tension patterns of those for the intact ACL under controlled in vitro loading conditions. By means of a robotic/universal force moment sensor (UFS) testing system, the in situ force vectors (both magnitude and direction) for the AM and PL bundles of the ACL, as well as their respective replacement grafts, were determined and compared on nine human cadaveric knees. It was found that double-bundle ACL reconstruction could closely replicate the in situ force vectors. Under a 134-N anterior tibial load, the resultant force vectors for the intact ACL and the reconstructed ACL had a difference of 5 to 11 N (p > 0.05) in magnitude and 1 to 13 degrees (p > 0.05) in direction. Whereas, under combined rotatory loads of 10-N-m valgus and 5-N-m internal tibial torques, the corresponding differences were 10 to 16 N and 4 degrees to 11 degrees, respectively. Again, there were no statistically significant differences except at 30 degrees of flexion where the force vector for the AM graft had a 15 degrees (p < 0.05) lower elevation angle than did the AM bundle.
Collapse
Affiliation(s)
- Changfu Wu
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, 300 Technology Drive, Room 405, Pittsburgh, Pennsylvania 15219, USA
| | | | | | | |
Collapse
|
32
|
Woo SLY, Liang R, Fisher MB. Future of Orthopaedic Sports Medicine and Soft Tissue Healing: The Important Role of Engineering. Cell Mol Bioeng 2009. [DOI: 10.1007/s12195-009-0065-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
|
33
|
Darcy SP, Gil JE, Woo SLY, Debski RE. The importance of position and path repeatability on force at the knee during six-DOF joint motion. Med Eng Phys 2009; 31:553-7. [DOI: 10.1016/j.medengphy.2008.11.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Revised: 11/03/2008] [Accepted: 11/07/2008] [Indexed: 10/21/2022]
|
34
|
Jung HJ, Fisher MB, Woo SLY. Role of biomechanics in the understanding of normal, injured, and healing ligaments and tendons. BMC Sports Sci Med Rehabil 2009; 1:9. [PMID: 19457264 PMCID: PMC2695438 DOI: 10.1186/1758-2555-1-9] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2009] [Accepted: 05/20/2009] [Indexed: 12/19/2022]
Abstract
Ligaments and tendons are soft connective tissues which serve essential roles for biomechanical function of the musculoskeletal system by stabilizing and guiding the motion of diarthrodial joints. Nevertheless, these tissues are frequently injured due to repetition and overuse as well as quick cutting motions that involve acceleration and deceleration. These injuries often upset this balance between mobility and stability of the joint which causes damage to other soft tissues manifested as pain and other morbidity, such as osteoarthritis. The healing of ligament and tendon injuries varies from tissue to tissue. Tendinopathies are ubiquitous and can take up to 12 months for the pain to subside before one could return to normal activity. A ruptured medial collateral ligament (MCL) can generally heal spontaneously; however, its remodeling process takes years and its biomechanical properties remain inferior when compared to the normal MCL. It is also known that a midsubstance anterior cruciate ligament (ACL) tear has limited healing capability, and reconstruction by soft tissue grafts has been regularly performed to regain knee function. However, long term follow-up studies have revealed that 20–25% of patients experience unsatisfactory results. Thus, a better understanding of the function of ligaments and tendons, together with knowledge on their healing potential, may help investigators to develop novel strategies to accelerate and improve the healing process of ligaments and tendons. With thousands of new papers published in the last ten years that involve biomechanics of ligaments and tendons, there is an increasing appreciation of this subject area. Such attention has positively impacted clinical practice. On the other hand, biomechanical data are complex in nature, and there is a danger of misinterpreting them. Thus, in these review, we will provide the readers with a brief overview of ligaments and tendons and refer them to appropriate methodologies used to obtain their biomechanical properties. Specifically, we hope the reader will pay attention to how the properties of these tissues can be altered due to various experimental and biologic factors. Following this background material, we will present how biomechanics can be applied to gain an understanding of the mechanisms as well as clinical management of various ligament and tendon ailments. To conclude, new technology, including imaging and robotics as well as functional tissue engineering, that could form novel treatment strategies to enhance healing of ligament and tendon are presented.
Collapse
Affiliation(s)
- Ho-Joong Jung
- Musculoskeletal Research Center, Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, USA.
| | | | | |
Collapse
|
35
|
Battaglia MJ, Lenhoff MW, Ehteshami JR, Lyman S, Provencher MT, Wickiewicz TL, Warren RF. Medial collateral ligament injuries and subsequent load on the anterior cruciate ligament: a biomechanical evaluation in a cadaveric model. Am J Sports Med 2009; 37:305-11. [PMID: 19098154 DOI: 10.1177/0363546508324969] [Citation(s) in RCA: 79] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Numerous studies have documented the effect of complete medial collateral ligament injury on anterior cruciate ligament loads; few have addressed how partial medial collateral ligament disruption affects knee kinematics. PURPOSE To determine knee kinematics and subsequent change in anterior cruciate ligament load in a partial and complete medial collateral ligament injury model. STUDY DESIGN Controlled laboratory study. METHODS Ten human cadaveric knees were sequentially tested by a robot with the medial collateral ligament intact, in a partial injury model, and in a complete injury model with a universal force-moment sensor measuring system. Tibial translation, rotation, and anterior cruciate ligament load were measured under 3 conditions: anterior load (125 N), valgus load (10 N x m), and internal-external rotation torque (4 N x m; all at 0 degrees and 30 degrees of flexion). RESULTS Anterior and posterior translation did not statistically increase with a partial or complete medial collateral ligament injury at 0 degrees and 30 degrees of flexion. In response to a 125 N anterior load, at 0 degrees , the anterior cruciate ligament load increased 8.7% (from 99.5 to 108.2 N; P = .006) in the partial injury and 18.3% (117.7 N; P < .001) in the complete injury; at 30 degrees , anterior cruciate ligament load was increased 12.3% (from 101.7 to 114.2 N; P = .001) in the partial injury and 20.6% (122.7 N; P < .001) in the complete injury. In response to valgus torque (10 N x m) at 30 degrees , anterior cruciate ligament load was increased 55.3% (30.4 to 47.2 N; P = .044) in the partial injury model and 185% (86.8 N; P = .001) in the complete injury model. In response to internal rotation torque (4 N.m) at 30 degrees , anterior cruciate ligament load was increased 29.3% (27.6 to 35.7 N; P = .001) in the partial injury model and 65.2% (45.6 N; P < .001) in the complete injury model. The amount of internal rotation at 30 degrees of flexion was significantly increased in the complete injury model (22.8 degrees ) versus the intact state (19.5 degrees ; P < .001). CONCLUSION Partial and complete medial collateral ligament tears significantly increased the load on the anterior cruciate ligament. In a partial tear, the resultant load on the anterior cruciate ligament was increased at 30 degrees of flexion and with valgus load and internal rotation torque. CLINICAL RELEVANCE Patients may need to be protected from valgus and internal rotation forces after anterior cruciate ligament reconstruction in the setting of a concomitant partial medial collateral ligament tear. This information may help clinicians understand the importance of partial injuries of the medial collateral ligament with a combined anterior cruciate ligament injury complex.
Collapse
Affiliation(s)
- Michael J Battaglia
- Shoulder and Sports Orthopedic Surgery, United States Naval Academy, 250 Wood Road, Annapolis, MD 21402, USA.
| | | | | | | | | | | | | |
Collapse
|
36
|
Abstract
In our research center, we have developed and utilized a novel robotic/universal force-moment sensor testing system to gain quantitative data on multiple-degree-of-freedom kinematics of the knee simultaneously with data on the in situ forces in normal and repaired soft tissues. In particular, we have investigated the complex interaction of the anteromedial and posterolateral bundles of the anterior cruciate ligament as well as several key biomechanical variables in anterior cruciate ligament reconstruction, such as graft selection and femoral tunnel placement (both of which impact knee stability). For example, both the bone-patellar tendon-bone and quadrupled hamstrings tendon autografts restored anterior stability but were insufficient in gaining rotatory stability. In a follow-up study, we have shown that a more laterally placed graft was beneficial and could improve these outcomes. Such findings led to additional investigation in which the biomechanical advantages of double-bundle anterior cruciate ligament reconstruction were demonstrated. However, a more laterally placed autograft at the femoral insertion of the posterolateral bundle also worked well, especially when the knee was nearly at full extension (a position in which the anterior cruciate ligament is needed most). At present, we are moving forward by obtaining in vivo kinematics data and then repeating those kinematics exactly to obtain new data with use of the robotic/universal force-moment sensor testing system in order to gain further insight regarding the function of the anterior cruciate ligament and anterior cruciate ligament replacement grafts in vivo. In parallel, we are developing a mathematical model of the knee and validating the computational model with experimental data. The combined approach will yield new and relevant information, including the stress and strain distribution in the anterior cruciate ligament and anterior cruciate ligament grafts. This will facilitate a better understanding of the function of the anterior cruciate ligament and a scientifically based design of surgical procedures and postoperative rehabilitation protocols that will lead to better patient outcomes.
Collapse
Affiliation(s)
- Savio L-Y. Woo
- Musculoskeletal Research Center, Swanson School of Engineering, Department of Bioengineering, 405 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219. E-mail address for S.L-Y. Woo:
| | - Matthew B. Fisher
- Musculoskeletal Research Center, Swanson School of Engineering, Department of Bioengineering, 405 Center for Bioengineering, 300 Technology Drive, Pittsburgh, PA 15219. E-mail address for S.L-Y. Woo:
| |
Collapse
|
37
|
Zantop T, Ferretti M, Bell KM, Brucker PU, Gilbertson L, Fu FH. Effect of tunnel-graft length on the biomechanics of anterior cruciate ligament-reconstructed knees: intra-articular study in a goat model. Am J Sports Med 2008; 36:2158-66. [PMID: 18669984 DOI: 10.1177/0363546508320572] [Citation(s) in RCA: 129] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND In anterior cruciate ligament (ACL) reconstruction using hamstring grafts, the graft can be looped, resulting in an increased graft diameter but reducing graft length within the tunnels. HYPOTHESIS After 6 and 12 weeks, structural properties and knee kinematics after soft tissue ACL reconstruction with 15 mm within the femoral tunnel will be significantly inferior when compared with the properties of ACL reconstruction with 25 mm in the tunnel. STUDY DESIGN Controlled laboratory study. METHODS In an intra-articular goat model, 36 ACL reconstructions using an Achilles tendon split graft were performed with 15-mm (18 knees) and 25-mm (18 knees) graft length in the femoral tunnel. Animals were sacrificed 6 weeks and 12 weeks after surgery and knee kinematics was tested. In situ forces as well as the structural properties were determined and compared with those in an intact control group. Histologic analyses were performed in 2 animals in each group 6 and 12 weeks postoperatively. Statistical analysis was performed using a 2-factor analysis of variance test. RESULTS Anterior cruciate ligament reconstructions with 15 mm resulted in significantly less anterior tibial translation after 6 weeks (P < .05) but not after 12 weeks. Kinematics after 12 weeks and in situ forces of the replacement grafts at both time points showed no statistically significant differences. Stiffness, ultimate failure load, and ultimate stress revealed no statistically significant differences between the 15-mm group and the 25-mm group. CONCLUSION The results suggest that there is no negative correlation between short graft length (15 mm) in the femoral tunnel and the resulting knee kinematics and structural properties. CLINICAL RELEVANCE Various clinical scenarios exist in which the length of available graft that could be pulled into the bone tunnel (femoral or tibial) could be in question. To address this concern, this study showed that reducing the tendon graft length in the femoral bone tunnel from 25 mm to 15 mm did not have adverse affects in a goat model.
Collapse
Affiliation(s)
- Thore Zantop
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
| | | | | | | | | | | |
Collapse
|
38
|
Stability Evaluation of Single-Bundle and Double-Bundle Reconstruction During Navigated ACL Reconstruction. Sports Med Arthrosc Rev 2008; 16:77-83. [DOI: 10.1097/jsa.0b013e318172b52c] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
39
|
Howard RA, Rosvold JM, Darcy SP, Corr DT, Shrive NG, Tapper JE, Ronsky JL, Beveridge JE, Marchuk LL, Frank CB. Reproduction of In Vivo Motion Using a Parallel Robot. J Biomech Eng 2007; 129:743-9. [PMID: 17887900 DOI: 10.1115/1.2768983] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Although alterations in knee joint loading resulting from injury have been shown to influence the development of osteoarthritis, actual in vivo loading conditions of the joint remain unknown. A method for determining in vivo ligament loads by reproducing joint specific in vivo kinematics using a robotic testing apparatus is described. The in vivo kinematics of the ovine stifle joint during walking were measured with 3D optical motion analysis using markers rigidly affixed to the tibia and femur. An additional independent single degree of freedom measuring device was also used to record a measure of motion. Following sacrifice, the joint was mounted in a robotic/universal force sensor test apparatus and referenced using a coordinate measuring machine. A parallel robot configuration was chosen over the conventional serial manipulator because of its greater accuracy and stiffness. Median normal gait kinematics were applied to the joint and the resulting accuracy compared. The mean error in reproduction as determined by the motion analysis system varied between 0.06mm and 0.67mm and 0.07deg and 0.74deg for the two individual tests. The mean error measured by the independent device was found to be 0.07mm and 0.83mm for the two experiments, respectively. This study demonstrates the ability of this system to reproduce in vivo kinematics of the ovine stifle joint in vitro. The importance of system stiffness is discussed to ensure accurate reproduction of joint motion.
Collapse
Affiliation(s)
- Ryan A Howard
- Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o Joint Injury and Arthritis Research Group, 3330 Hospital Drive, Calgary, Alberta, Canada T2N 4N1.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Walker MR, Dickey JP. New methodology for multi-dimensional spinal joint testing with a parallel robot. Med Biol Eng Comput 2007; 45:297-304. [PMID: 17235615 DOI: 10.1007/s11517-006-0158-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2006] [Accepted: 12/23/2006] [Indexed: 10/23/2022]
Abstract
Six degree-of-freedom (6DOF) robots can be used to examine joints and their mechanical properties with the spatial freedom encountered physiologically. Parallel robots are capable of 6DOF motion under large payloads making them ideal for joint testing. This study developed and assessed novel methods for spinal joint testing with a custom-built parallel robot implementing hybrid load-position control. We hypothesized these methods would allow multi-dimensional control of joint loading scenarios, resulting in physiological joint motions. Tests were performed in 3DOF and 6DOF. 3DOF methods controlled the forces and the principal moment within +/-10 N and 0.25 N m under combined bending and compressive loads. 6DOF tests required larger tolerances for convergence due to machine compliance, however expected motion patterns were still observed. The unique mechanism and control approaches show promise for enabling complex three-dimensional loading patterns for in vitro joint biomechanics, and could facilitate research using specimens with unknown, changing, or nonlinear load-deformation properties.
Collapse
Affiliation(s)
- Matthew R Walker
- Motion Analysis Laboratory, Shriners Hospitals for Children, 1645 West 8th Street, Erie, PA 16505, USA.
| | | |
Collapse
|
41
|
Woo SLY, Wu C, Dede O, Vercillo F, Noorani S. Biomechanics and anterior cruciate ligament reconstruction. J Orthop Surg Res 2006; 1:2. [PMID: 17150122 PMCID: PMC1635005 DOI: 10.1186/1749-799x-1-2] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2006] [Accepted: 09/25/2006] [Indexed: 12/11/2022] Open
Abstract
For years, bioengineers and orthopaedic surgeons have applied the principles of mechanics to gain valuable information about the complex function of the anterior cruciate ligament (ACL). The results of these investigations have provided scientific data for surgeons to improve methods of ACL reconstruction and postoperative rehabilitation. This review paper will present specific examples of how the field of biomechanics has impacted the evolution of ACL research. The anatomy and biomechanics of the ACL as well as the discovery of new tools in ACL-related biomechanical study are first introduced. Some important factors affecting the surgical outcome of ACL reconstruction, including graft selection, tunnel placement, initial graft tension, graft fixation, graft tunnel motion and healing, are then discussed. The scientific basis for the new surgical procedure, i.e., anatomic double bundle ACL reconstruction, designed to regain rotatory stability of the knee, is presented. To conclude, the future role of biomechanics in gaining valuable in-vivo data that can further advance the understanding of the ACL and ACL graft function in order to improve the patient outcome following ACL reconstruction is suggested.
Collapse
Affiliation(s)
- Savio L-Y Woo
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pennsylvania, USA
| | - Changfu Wu
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pennsylvania, USA
| | - Ozgur Dede
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pennsylvania, USA
| | - Fabio Vercillo
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pennsylvania, USA
| | - Sabrina Noorani
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pennsylvania, USA
| |
Collapse
|
42
|
Kilger RHP, Stehle J, Fisk JA, Thomas M, Miura K, Woo SLY. Anatomical double-bundle anterior cruciate ligament reconstruction after valgus high tibial osteotomy: a biomechanical study. Am J Sports Med 2006; 34:961-7. [PMID: 16436536 DOI: 10.1177/0363546505283269] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Although anatomical double-bundle anterior cruciate ligament reconstruction can successfully restore normal knee biomechanics for knees with typical varus-valgus alignment, the efficacy of the same reconstruction method for knees after a valgus high tibial osteotomy is unclear. HYPOTHESIS Anatomical double-bundle anterior cruciate ligament reconstruction for valgus knees after a high tibial osteotomy cannot restore normal knee kinematics and can result in abnormally high in situ forces in the ligament graft. STUDY DESIGN Controlled laboratory study. METHODS Ten cadaveric knees were subjected to valgus high tibial osteotomy followed by an anatomical double-bundle anterior cruciate ligament reconstruction. The valgus knees were tested using a robotic/universal force-moment sensor system before and after the ligament reconstruction. The knee kinematics in response to anterior tibial load and combined rotatory loads, as well as the corresponding in situ forces of the anterior cruciate ligament bundles and grafts, were compared between the ligament-intact and ligament-reconstructed valgus knees. RESULTS After reconstruction, the anterior tibial translation and internal tibial rotation for the valgus knee decreased approximately 2 mm and 2 degrees , respectively, at low flexion angles compared with those of the anterior cruciate ligament-intact knee (P < .05). The in situ forces in the posterolateral graft became 56% to 200% higher than those in the posterolateral bundle of the intact anterior cruciate ligament (P < .05). CONCLUSION Performing an anatomical double-bundle anterior cruciate ligament reconstruction on knees after valgus high tibial osteotomy may overconstrain the knee and result in high forces in the posterolateral graft, which could predispose it to failure. CLINICAL RELEVANCE Modifications of anterior cruciate ligament reconstruction procedures to reduce posterolateral graft force may be needed for valgus knees after a high tibial osteotomy.
Collapse
Affiliation(s)
- Robert H P Kilger
- Musculoskeletal Research Center, 405 Center for Bioengineering, 300 Technology Drive, P.O. Box 71199, Pittsburgh, PA 15213, USA
| | | | | | | | | | | |
Collapse
|
43
|
Hsu WH, Fisk JA, Yamamoto Y, Debski RE, Woo SLY. Differences in torsional joint stiffness of the knee between genders: a human cadaveric study. Am J Sports Med 2006; 34:765-70. [PMID: 16399932 DOI: 10.1177/0363546505282623] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND In many sports, female athletes have a higher incidence of anterior cruciate ligament injury than do male athletes. Among many risk factors, the lower rotatory joint stiffness of female knees has been suggested for the increased rate of anterior cruciate ligament injuries. HYPOTHESIS In response to combined rotatory loads, female knees have significantly lower torsional joint stiffness and higher rotatory joint laxity than do male knees at low flexion angles, despite the fact that no such gender differences would be found in response to an anterior tibial load. STUDY DESIGN Comparative laboratory study. METHODS Joint kinematics of 82 human cadaveric knees (38 female, 44 male) in response to (1) combined rotatory loads of 10 N x m valgus and +/- 5 N x m internal tibial torques and (2) a 134-N anterior-posterior tibial load were measured using a robotic/universal force-moment sensor testing system. RESULTS In response to combined rotatory loads, female knees had as much as 25% lower torsional joint stiffness (female: 0.79 N x m/deg; 95% confidence interval, 0.67-0.91; male: 1.06 N x m/deg; 95% confidence interval, 0.95-1.17) and up to 35% higher rotatory joint laxity (female: 26.2 degrees; 95% confidence interval, 24.5 degrees-27.9 degrees; male: 20.5 degrees; 95% confidence interval, 18.8 degrees-22.2 degrees) than did male knees (P < .05), whereas there were no gender differences in response to the anterior tibial load (P > .05). CONCLUSION Female knees had lower torsional joint stiffness and higher rotatory joint laxity than did male knees in response to combined rotatory loads. CLINICAL RELEVANCE Larger axial rotations of female knees in response to rotatory loads may affect the distribution of forces in soft tissues and the function of muscles that provide knee stability. Control algorithms used during the biomechanical testing of cadaveric knees and computational knee models might need to be gender specific.
Collapse
Affiliation(s)
- Wei-Hsiu Hsu
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Chia-Yi, Taiwan
| | | | | | | | | |
Collapse
|
44
|
Lenschow S, Zantop T, Weimann A, Lemburg T, Raschke M, Strobel M, Petersen W. Joint kinematics and in situ forces after single bundle PCL reconstruction: a graft placed at the center of the femoral attachment does not restore normal posterior laxity. Arch Orthop Trauma Surg 2006; 126:253-9. [PMID: 16273379 DOI: 10.1007/s00402-005-0062-9] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2004] [Indexed: 12/17/2022]
Abstract
INTRODUCTION Femoral tunnel placement has a great influence on the clinical outcome after PCL reconstruction. MATERIALS AND METHODS Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of human knees following soft-tissue single bundle PCL reconstruction fixed at the center of the femoral attachment. RESULTS Posterior tibial translation significantly increased at all flexion angles after transsection of the posterior cruciate ligament (p<0.05). PCL reconstruction resulted in significantly less posterior tibial translation at all flexion angles when compared to the PCL deficient knee (p<0.05). The differences in the in situ force between the intact ligament and the reconstructed graft were statistical significant (p<0.05). CONCLUSION Single bundle PCL reconstruction with a soft-tissue graft fixed at the center of the femoral attachment is able to reduce the posterior tibial translation significantly. However, it cannot restore kinematics of the intact knee and in situ forces of the intact PCL.
Collapse
Affiliation(s)
- Simon Lenschow
- Department of Orthopaedic Surgery, Christian-Albrechts-University, Kiel, Germany
| | | | | | | | | | | | | |
Collapse
|
45
|
Petersen W, Lenschow S, Weimann A, Strobel MJ, Raschke MJ, Zantop T. Importance of femoral tunnel placement in double-bundle posterior cruciate ligament reconstruction: biomechanical analysis using a robotic/universal force-moment sensor testing system. Am J Sports Med 2006; 34:456-63. [PMID: 16303880 DOI: 10.1177/0363546505281239] [Citation(s) in RCA: 68] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Previous studies have identified the femoral attachment of the posterior cruciate ligament fibers as one of the primary determinants of fiber tension behavior. In addition, a double-bundle posterior cruciate ligament reconstruction has been shown to restore the intact knee kinematics more closely than does a single-bundle reconstruction. HYPOTHESIS An anterior tunnel position in double-bundle posterior cruciate ligament reconstruction restores the biomechanics of the normal knee more closely than does a posterior tunnel position. STUDY DESIGN Controlled laboratory study. METHODS Kinematics and in situ forces of human knees after double-bundle posterior cruciate ligament reconstruction with 2 different femoral tunnel positions (anterior vs posterior) were evaluated using a robotic/universal force-moment sensor testing system. Within the same specimen, the resulting knee kinematics and in situ forces were compared. For statistical analysis, 2-way analysis of variance repeated measures were performed. RESULTS The femoral tunnel position of the double-bundle hamstring graft had significant effect on the resulting posterior tibial displacement and in situ forces of the hamstring grafts. The anterior femoral tunnel position provided significantly less posterior tibial translation than did the posterior tunnel position. There was a tendency toward higher in situ forces of grafts fixed in the anterior tunnel when compared to the posterior position, but this difference was statistically not significant. CONCLUSION An anterior position of the bone tunnels in double-bundle posterior cruciate ligament reconstruction restores the normal knee kinematics more closely than does a posterior position of the tunnels. CLINICAL RELEVANCE In double-bundle posterior cruciate ligament reconstruction, posterior placement of the tunnel should be avoided.
Collapse
Affiliation(s)
- Wolf Petersen
- Department of Trauma-, Hand-, and Reconstructive Surgery, Wilhelms University Muenster, Waldeyerstr. 1, D-48149 Muenster, Germany
| | | | | | | | | | | |
Collapse
|
46
|
Moore SM, Thomas M, Woo SLY, Gabriel MT, Kilger R, Debski RE. A novel methodology to reproduce previously recorded six-degree of freedom kinematics on the same diarthrodial joint. J Biomech 2006; 39:1914-23. [PMID: 16005464 DOI: 10.1016/j.jbiomech.2005.05.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2004] [Accepted: 05/11/2005] [Indexed: 11/29/2022]
Abstract
The objective of this study was to develop a novel method to more accurately reproduce previously recorded 6-DOF kinematics of the tibia with respect to the femur using robotic technology. Furthermore, the effect of performing only a single or multiple registrations and the effect of robot joint configuration were investigated. A single registration consisted of registering the tibia and femur with respect to the robot at full extension and reproducing all kinematics while multiple registrations consisted of registering the bones at each flexion angle and reproducing only the kinematics of the corresponding flexion angle. Kinematics of the knee in response to an anterior (134 N) and combined internal/external (+/-10 N m) and varus/valgus (+/-5 N m) loads were collected at 0 degrees , 15 degrees , 30 degrees , 60 degrees , and 90 degrees of flexion. A six axes, serial-articulated robotic manipulator (PUMA Model 762) was calibrated and the working volume was reduced to improve the robot's accuracy. The effect of the robot joint configuration was determined by performing single and multiple registrations for three selected configurations. For each robot joint configuration, the accuracy in position of the reproduced kinematics improved after multiple registrations (0.7+/-0.3, 1.2+/-0.5, and 0.9+/-0.2 mm, respectively) when compared to only a single registration (1.3+/-0.9, 2.0+/-1.0, and 1.5+/-0.7 mm, respectively) (p<0.05). The accuracy in position of each robot joint configuration was unique as significant differences were detected between each of the configurations. These data demonstrate that the number of registrations and the robot joint configuration both affect the accuracy of the reproduced kinematics. Therefore, when using robotic technology to reproduce previously recorded kinematics, it may be necessary to perform these analyses for each individual robotic system and for each diarthrodial joint, as different joints will require the robot to be placed in different robot joint configurations.
Collapse
Affiliation(s)
- Susan M Moore
- Department of Bioengineering, Musculoskeletal Research Center, University of Pittsburgh, 405 Center for Bioengineering, 300 Technology Drive, PA 15219, USA
| | | | | | | | | | | |
Collapse
|
47
|
|
48
|
Kilger RHP, Thomas M, Hanford S, Alaseirlis DA, Paessler HH, Woo SLY. The effectiveness of reconstruction of the anterior cruciate ligament using the novel knot/press-fit technique: a cadaveric study. Am J Sports Med 2005; 33:856-63. [PMID: 15827354 DOI: 10.1177/0363546504271745] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND A variety of fixation devices are used for anterior cruciate ligament reconstruction with hamstring tendon grafts. These devices increase costs and can present artifacts in magnetic resonance imaging as well as complications in revision surgery. Therefore, a novel knot/press-fit technique that requires no implantable devices has been introduced. NULL HYPOTHESIS The knot/press-fit technique restores knee kinematics as well as the more commonly used EndoButton CL fixation and has similar biomechanical properties as other devices published in the literature. STUDY DESIGN Controlled laboratory study. METHODS Eight fresh-frozen cadaveric knees (52 +/- 7 years) were tested using a robotic/universal force-moment sensor testing system. The knee kinematics of the intact, anterior cruciate ligament-deficient, EndoButton-reconstructed, and knot/press-fit-reconstructed knee in response to both a 134-N anterior tibial load and a combined rotatory load at multiple knee flexion angles was determined. Differences between the 4 knee states were evaluated with a 2-factor repeated-measures analysis of variance (P < .05). To determine the stiffness and strength of the knot/press-fit fixation, the femur-graft-tibia complex was tested in uniaxial tension. RESULTS In response to an anterior tibial load, the anterior tibial translation for the knot/press-fit reconstruction was found to be not significantly different from that of the intact anterior cruciate ligament as well as that of the EndoButton reconstruction (P > .05). In response to a combined rotatory load, neither reconstruction procedure could effectively reduce the coupled anterior tibial translation to that of the intact knee, and no significant difference between the 2 reconstructions could be detected (P > .05). The stiffness of the knot/press-fit complex was found to be 37.8 +/- 9.6 N/mm, and the load at failure was 540 +/- 97.7 N, which is equal to other devices published in the literature. CLINICAL RELEVANCE The experiment suggests that the knot/press-fit technique may be a reliable alternative for the femoral fixation of hamstring tendon grafts.
Collapse
Affiliation(s)
- Robert H P Kilger
- Musculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | | | | | | | | |
Collapse
|
49
|
Woo SLY, Abramowitch SD, Kilger R, Liang R. Biomechanics of knee ligaments: injury, healing, and repair. J Biomech 2005; 39:1-20. [PMID: 16271583 DOI: 10.1016/j.jbiomech.2004.10.025] [Citation(s) in RCA: 199] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2004] [Accepted: 10/20/2004] [Indexed: 02/08/2023]
Abstract
Knee ligament injuries are common, particularly in sports and sports related activities. Rupture of these ligaments upsets the balance between knee mobility and stability, resulting in abnormal knee kinematics and damage to other tissues in and around the joint that lead to morbidity and pain. During the past three decades, significant advances have been made in characterizing the biomechanical and biochemical properties of knee ligaments as an individual component as well as their contribution to joint function. Further, significant knowledge on the healing process and replacement of ligaments after rupture have helped to evaluate the effectiveness of various treatment procedures. This review paper provides an overview of the current biological and biomechanical knowledge on normal knee ligaments, as well as ligament healing and reconstruction following injury. Further, it deals with new and exciting functional tissue engineering approaches (ex. growth factors, gene transfer and gene therapy, cell therapy, mechanical factors, and the use of scaffolding materials) aimed at improving the healing of ligaments as well as the interface between a replacement graft and bone. In addition, it explores the anatomical, biological and functional perspectives of current reconstruction procedures. Through the utilization of robotics technology and computational modeling, there is a better understanding of the kinematics of the knee and the in situ forces in knee ligaments and replacement grafts. The research summarized here is multidisciplinary and cutting edge that will ultimately help improve the treatment of ligament injuries. The material presented should serve as an inspiration to future investigators.
Collapse
Affiliation(s)
- Savio L-Y Woo
- Department of Bioengineering, Musculoskeletal Research Center, University of Pittsburgh, Pittsburgh, PA 15219, USA.
| | | | | | | |
Collapse
|
50
|
Yamamoto Y, Hsu WH, Woo SLY, Van Scyoc AH, Takakura Y, Debski RE. Knee stability and graft function after anterior cruciate ligament reconstruction: a comparison of a lateral and an anatomical femoral tunnel placement. Am J Sports Med 2004; 32:1825-32. [PMID: 15572308 DOI: 10.1177/0363546504263947] [Citation(s) in RCA: 314] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Locations of femoral tunnels for anterior cruciate ligament replacement grafts remain a subject of debate. HYPOTHESIS A lateral femoral tunnel placed at the insertion of the posterolateral bundle of the anterior cruciate ligament can restore knee function comparably to anatomical femoral tunnel placement. STUDY DESIGN Controlled laboratory study. METHODS Ten cadaveric knees were subjected to the following external loading conditions: (1) a 134-N anterior tibial load and (2) combined rotatory loads of 10-N.m valgus and 5-N.m internal tibial torques. Data on resulting knee kinematics and in situ force of the intact anterior cruciate ligament and anterior cruciate ligament graft were collected using a robotic/universal force-moment sensor testing system for (1) intact, (2) anterior cruciate ligament-deficient, (3) anatomical double-bundle reconstructed, and (4) laterally placed single-bundle reconstructed knees. RESULTS In response to anterior tibial load, anterior tibial translation and in situ force in the graft were not significantly different between the 2 reconstructions except at high knee flexion. For example, at 90 degrees of knee flexion, anterior tibial translation was 6.1 +/- 2.3 mm for anatomical double-bundle reconstruction and 7.6 +/- 2.6 mm for laterally placed single-bundle reconstruction (P < .05). In response to rotatory loads, there were no significant differences between the 2 reconstruction procedures (4.8 +/- 2.4 mm vs 4.8 +/- 3.0 mm in anterior tibial translation at 15 degrees of knee flexion, P > .05). CONCLUSION Lateral tunnel placement can restore rotatory and anterior knee stability similarly to an anatomical reconstruction when the knee is near extension. However, the same is not true when the knee is at high flexion angles. CLINICAL RELEVANCE To reproduce the complex function of the anterior cruciate ligament, reproducing both bundles of the anterior cruciate ligament may be necessary.
Collapse
Affiliation(s)
- Yuji Yamamoto
- Musculoskeletal Research Center, Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | | | | | | | | | | |
Collapse
|