1
|
Chatziprodromidou IP, Savoglidou I, Stavrou V, Vantarakis G, Vantarakis A. Surveillance of Legionella spp. in Open Fountains: Does It Pose a Risk? Microorganisms 2022; 10:2458. [PMID: 36557711 PMCID: PMC9781103 DOI: 10.3390/microorganisms10122458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/21/2022] [Accepted: 12/03/2022] [Indexed: 12/14/2022] Open
Abstract
Clusters of outbreaks or cases of legionellosis have been linked to fountains. The function of fountains, along with their inadequate design and poor sanitation, in combination with the warm Mediterranean climate, can favor the proliferation of Legionella in water systems. Public fountains in Mediterranean cities may pose a significant risk for public health due to the aerosolization of water. Nevertheless, few studies have been conducted on Legionella and the risk of infection in humans through fountains. In our study, the presence and quantity of Legionella spp. in fifteen external public fountains were investigated. Two samplings were performed in two different periods (dry and wet). Sixty samples were collected, quantified and analyzed with a culture ISO method. The operation of all fountains was evaluated twice using a standardized checklist. In accordance with their operation, a ranking factor (R factor) was suggested. Finally, based on these results, a quantitative microbial risk assessment was performed. Thirty water samples taken from the fountains (100%) during the dry sampling period were positive for Legionella (mean log concentration: 3.64 ± 0.45 cfu/L), whereas 24 water samples taken from the fountains during the wet period were Legionella-positive (mean log concentration: 2.36 ± 1.23 cfu/L). All fountains were classified as unsatisfactory according to the checklist for the evaluation of their function. A statistically significant correlation was found between Legionella concentration and the assessment score. The risk of Legionella infection was estimated in both periods, with higher risk in the dry period. The surveillance and risk assessment of Legionella spp. in the fountains of Patras confirmed a high prevalence and a high risk to public health.
Collapse
Affiliation(s)
- Ioanna P. Chatziprodromidou
- Environmental Microbiology, Department of Public Health, Medical School, University of Patras, 265 04 Patras, Greece
| | | | | | | | - Apostolos Vantarakis
- Environmental Microbiology, Department of Public Health, Medical School, University of Patras, 265 04 Patras, Greece
| |
Collapse
|
2
|
De Giglio O, Napoli C, Diella G, Fasano F, Lopuzzo M, Apollonio F, D'Ambrosio M, Campanale C, Triggiano F, Caggiano G, Montagna MT. Integrated approach for legionellosis risk analysis in touristic-recreational facilities. ENVIRONMENTAL RESEARCH 2021; 202:111649. [PMID: 34252427 DOI: 10.1016/j.envres.2021.111649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 06/13/2023]
Abstract
Legionellosis is a severe pneumonia caused by the inhalation of aerosols containing Legionella, Gram-negative bacteria present in the water systems of touristic-recreational facilities. The purpose of this study was to develop a scoring tool to predict the risk of both environmental contamination and Legionnaires' disease cases in such facilities in the Apulia region of southern Italy. We analyzed 47 structural and management parameters/risk factors related to the buildings, water systems, and air conditioning at the facilities. A Poisson regression model was used to compute an overall risk score for each facility with respect to three outcomes: water samples positive for Legionella (risk score range: 7-54), water samples positive for Legionella with an average load exceeding 1000 colony-forming units per liter (CFU/L) (risk score range: 22-179,871), and clinical cases of Legionnaire's disease (risk score range: 6-31). The cut-off values for three outcomes were determined by receiver operating characteristic curves (first outcome, samples positive for Legionella in a touristic-recreational facility: 19; second outcome, samples positive for Legionella in a touristic-recreational facility with an average load exceeding 1000 CFU/L: 2062; third outcome, clinical cases of Legionnaire's disease in a touristic-recreational facility: 22). Above these values, there was a significant probability of observing the outcome. We constructed this predictive model using 70% of a large dataset (18 years of clinical and environmental surveillance) and tested the model on the remaining 30% of the dataset to demonstrate its reliability. Our model enables the assessment of risk for a touristic facility and the creation of a conceptual framework to link the risk analysis with prevention measures.
Collapse
Affiliation(s)
- Osvalda De Giglio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Christian Napoli
- Department of Medical Surgical Sciences and Translational Medicine, "Sapienza" University of Rome, Via di Grottarossa 1035/1039, 00189, Rome, Italy.
| | - Giusy Diella
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Fabrizio Fasano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Marco Lopuzzo
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Francesca Apollonio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Marilena D'Ambrosio
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Carmen Campanale
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Francesco Triggiano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Giuseppina Caggiano
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| | - Maria Teresa Montagna
- Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy.
| |
Collapse
|
3
|
Kyritsi MA, Mouchtouri VA, Katsioulis A, Kostara E, Nakoulas V, Hatzinikou M, Hadjichristodoulou C. Legionella Colonization of Hotel Water Systems in Touristic Places of Greece: Association with System Characteristics and Physicochemical Parameters. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:E2707. [PMID: 30513698 PMCID: PMC6313630 DOI: 10.3390/ijerph15122707] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 11/21/2018] [Accepted: 11/25/2018] [Indexed: 11/17/2022]
Abstract
This study aimed to assess the colonization of hotel water systems in central Greece and Corfu by Legionella, and to investigate the association between physicochemical parameters and Legionella colonization. Standardized hygiene inspection was conducted in 51 hotels, and 556 water samples were analyzed for Legionella spp. Free chlorine concentration, pH, hardness, conductivity, and trace metals were defined in cold water samples. The results of inspections and chemical analyses were associated with the microbiological results using univariate and logistic regression analysis. According to the score of the checklist used for the inspections, 17.6% of the hotels were classified as satisfactory, 15.7% as adequate, and 66.7% as unsatisfactory. Moreover, 74.5% of the hotels were colonized by Legionella spp. and 31.4% required remedial measures according to the European guidelines. Legionella spp. were isolated in 28% of the samples. Unsatisfactory results of inspections were associated with Legionella presence (relative risk (RR) = 7.67, p-value = 0.043). In hot-water systems, <50 °C temperatures increased the risk of Legionella colonization (RR = 5.36, p-value < 0.001). In cold-water systems, free chlorine concentration <0.375 mg/L (odds ratio (OR) = 9.76, p-value = 0.001), pH ≥ 7.45 (OR = 4.05, p-value = 0.007), and hardness ≥321 mgCaCO₃/L (OR = 5.63, p-value = 0.003) increased the risk, whereas copper pipes demonstrated a protective role (OR = 0.29, p-value = 0.0024). The majority of the hotels inspected were colonized with Legionella. Supplementary monitoring of the risk factors that were identified should be considered.
Collapse
Affiliation(s)
- Maria A Kyritsi
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
| | - Varvara A Mouchtouri
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
| | - Antonis Katsioulis
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
- Regional Public Health Laboratory of Thessaly, 41222 Larissa, Greece.
| | - Elina Kostara
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
| | - Vasileios Nakoulas
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
| | - Marina Hatzinikou
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
- Regional Public Health Laboratory of Thessaly, 41222 Larissa, Greece.
| | - Christos Hadjichristodoulou
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, 41222 Larissa, Greece.
- Regional Public Health Laboratory of Thessaly, 41222 Larissa, Greece.
| |
Collapse
|
4
|
Montagna MT, De Giglio O, Napoli C, Diella G, Rutigliano S, Agodi A, Auxilia F, Baldovin T, Bisetto F, Arnoldo L, Brusaferro S, Busetti M, Calagreti G, Casini B, Cristina ML, Di Luzio R, Fiorio M, Formoso M, Liguori G, Martini E, Molino A, Mondello P, Mura I, Novati R, Orsi GB, Patroni A, Poli A, Privitera G, Ripabelli G, Rocchetti A, Rose F, Sarti M, Savini S, Silvestri A, Sodano L, Spagnolo AM, Tardivo S, Teti V, Torregrossa MV, Torri E, Veronesi L, Zarrilli R, Pacifico C, Goglio A, Moro M, Pasquarella C. Control and prevention measures for legionellosis in hospitals: A cross-sectional survey in Italy. ENVIRONMENTAL RESEARCH 2018; 166:55-60. [PMID: 29864633 DOI: 10.1016/j.envres.2018.05.030] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 05/09/2018] [Accepted: 05/27/2018] [Indexed: 06/08/2023]
Abstract
Risk assessment, environmental monitoring, and the disinfection of water systems are the key elements in preventing legionellosis risk. The Italian Study Group of Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine, and Public Health and the Italian Multidisciplinary Society for the Prevention of Health Care-Associated Infections carried out a national cross-sectional survey to investigate the measures taken to prevent and control legionellosis in Italian hospitals. A multiple-choice questionnaire was developed, comprising 71 questions regarding hospital location, general characteristics, clinical and environmental surveillance, and control and preventive measures for legionellosis in 2015. Overall, 739 hospitals were enrolled from February to June 2017, and 178 anonymous questionnaires were correctly completed and evaluated (response rate: 24.1%). The survey was conducted using the SurveyMonkey® platform, and the data were analyzed using Stata 12 software. Of the participating hospitals, 63.2% reported at least one case of legionellosis, of which 28.2% were of proven nosocomial origin. The highest case numbers were reported in the Northern Italy, in hospitals with a pavilion structure or cooling towers, and in hospitals with higher numbers of beds, wards and operating theaters. Laboratory diagnosis was performed using urinary antigen testing alone (31.9%), both urinary antigen testing and single antibody titer (17.8%), or with seroconversion also added (21.5%). Culture-based or molecular investigations were performed in 28.8% and 22.1% of the clinical specimens, respectively. The water systems were routinely tested for Legionella in 97.4% of the hospitals, 62% of which detected a positive result (> 1000 cfu/L). Legionella pneumophila serogroup 2-15 was the most frequently isolated species (58.4%). The most common control measures were the disinfection of the water system (73.7%), mostly through thermal shock (37.4%) and chlorine dioxide (34.4%), and the replacement (69.7%) or cleaning (70.4%) of faucets and showerheads. A dedicated multidisciplinary team was present in 52.8% of the hospitals, and 73% of the hospitals performed risk assessment. Targeted training courses were organized in 36.5% of the hospitals, involving nurses (30.7%), physicians (28.8%), biologists (21.5%), technicians (26.4%), and cleaners (11%). Control and prevention measures for legionellosis are present in Italian hospitals, but some critical aspects should be improved. More appropriate risk assessment is necessary, especially in large facilities with a high number of hospitalizations. Moreover, more sensitive diagnostic tests should be used, and dedicated training courses should be implemented.
Collapse
Affiliation(s)
- Maria Teresa Montagna
- Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Square G. Cesare 11, 70124 Bari, Italy.
| | - Osvalda De Giglio
- Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Square G. Cesare 11, 70124 Bari, Italy
| | - Christian Napoli
- Department of Medical and S urgical Sciences and Translational Medicine, Sapienza University of Roma, Square A. Moro 5, 00185 Roma, Italy
| | - Giusy Diella
- Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Square G. Cesare 11, 70124 Bari, Italy
| | - Serafina Rutigliano
- Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Square G. Cesare 11, 70124 Bari, Italy
| | - Antonella Agodi
- Department of Medical and Surgical Sciences and Advanced Technologies 'GF Ingrassia', University of Catania, Str. S. Sofia, 87, Comparto 10 Edificio C, 95123 Catania, Italy
| | - Francesco Auxilia
- Department of Biomedical Sciences for Health, University of Milano, Str. Pascal 36, 20133 Milano, Italy
| | - Tatjana Baldovin
- Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Hygiene and Public Health Unit, Str. Loredan, 18.35131 Padova, Italy
| | - Francesco Bisetto
- Presidio Ospedaliero di Camposampiero, AULss6 Euganea Str. P. Cosma 1, 35012 Camposampiero, PD, Italy
| | - Luca Arnoldo
- Department of Medicine, University of Udine, Str. Colugna 50, 33100 Udine, Italy
| | - Silvio Brusaferro
- Department of Medicine, University of Udine, Str. Colugna 50, 33100 Udine, Italy
| | - Marina Busetti
- University Hospital ASUITS, Microbiology Unit, Strada di Fiume, 447, 34149 Trieste, Italy
| | - Gioia Calagreti
- Hospital "Alto Tevere", AUSL Umbria 1, Città di Castello, PG, Italy
| | - Beatrice Casini
- Department of Translational Research, N.T.M.S. - Hygiene and Epidemiology Unit, University of Pisa, Str. S. Zeno 35-39, 56127 Pisa, Italy
| | - Maria Luisa Cristina
- Department of Health Sciences, University of Genova, Str. A. Pastore 1, 16132 Genova, Italy
| | | | | | - Maurizio Formoso
- Hospital "Miulli", Str. 127 km 4.1, Santeramo-Acquaviva delle Fonti, BA, Italy
| | - Giorgio Liguori
- Department of Movement Sciences and Wellbeing, University "Parthenope", Napoli, Italy
| | - Enrica Martini
- AOU "Ospedali Riuniti", Str. Conca, 71, 60126 Ancona, Italy
| | - Andrea Molino
- Hospital "Madonna delle Grazie", Contrada Cattedra Ambulante s.nc. 75100 Matera, Italy
| | | | - Ida Mura
- Department of Biomedical Science, University of Sassari, Sassari, Italy
| | | | - Giovanni Battista Orsi
- Department of Public Health and Infectious Disease, Sapienza University of Roma, Roma, Italy
| | - Andrea Patroni
- ASST Valcamonica, Str. Manzoni 142, 25040 Esine, BS, Italy
| | - Anna Poli
- Hospital "San Giovanni di Dio", Str. Torre Galli 3, 50143 Firenze, Italy
| | - Gaetano Privitera
- Department of Translational Research, N.T.M.S. - Hygiene and Epidemiology Unit, University of Pisa, Str. S. Zeno 35-39, 56127 Pisa, Italy
| | - Giancarlo Ripabelli
- Department of Medicine and Health Sciences "Vincenzo Tiberio", University of Molise, Campobasso, Italy
| | - Andrea Rocchetti
- ASO "SS. Antonio, Biagio and C. Arrigo", Str. Venezia 17, 15121 Alessandria, Italy
| | | | - Mario Sarti
- Hospital "OCSAE", Str. Giardini 1355, Baggiovara, MO, Italy
| | - Sandra Savini
- AOU "Ospedali Riuniti", Str. Conca, 71, 60126 Ancona, Italy
| | - Antonio Silvestri
- Hospital "San Camillo Forlanini", Circonvallazione Gianicolense 87, 00152 Roma, Italy
| | - Luisa Sodano
- Hospital "San Camillo Forlanini", Circonvallazione Gianicolense 87, 00152 Roma, Italy
| | - Anna Maria Spagnolo
- Department of Health Sciences, University of Genova, Str. A. Pastore 1, 16132 Genova, Italy
| | - Stefano Tardivo
- Department of Diagnostic and Public Health, University of Verona, Str. Le Grazie 8, 37134 Verona, Italy
| | | | - Maria Valeria Torregrossa
- Department of Sciences for Health Promotion and Mother-Child Care "G. D'Alessandro", University of Palermo, Str. Vespro, 133, 90127 Palermo, Italy
| | - Emanuele Torri
- Department of Health ans Social Policy, Str. Gilli 4, 38123 Trento, Italy
| | - Licia Veronesi
- Department of Medicine and Surgery, University of Parma, Str. Volturno 39, Parma, Italy
| | - Raffaele Zarrilli
- Department of Public Health, University of Napoli "Federico II", Str. S. Pansini, 5, Napoli, Italy
| | - Claudia Pacifico
- Centre of Biostatistics for Clinical Epidemiology, School of Medicine and Surgery, University of Milano-Bicocca, Milano, Italy
| | | | - Matteo Moro
- Hospital "San Raffaele", Str. Olgettina 60, 20132 Milano, Italy
| | - Cesira Pasquarella
- Department of Medicine and Surgery, University of Parma, Str. Volturno 39, Parma, Italy
| |
Collapse
|
5
|
Legionella spp. Risk Assessment in Recreational and Garden Areas of Hotels. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:ijerph15040598. [PMID: 29587446 PMCID: PMC5923640 DOI: 10.3390/ijerph15040598] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2018] [Revised: 03/22/2018] [Accepted: 03/22/2018] [Indexed: 12/16/2022]
Abstract
Several Travel-associated Legionnaires’ disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to better comprehend the colonization and to calculate the risk to human health of these sites. From July 2000–November 2017, the public health authorities of the Island of Crete (Greece) inspected 119 hotels associated with TALD, as reported through the European Legionnaires’ Disease Surveillance Network. Five hundred and eighteen samples were collected from decorative fountain ponds, showers near pools and spas, swimming pools, spa pools, garden sprinklers, drip irrigation systems (reclaimed water) and soil. Of those, 67 (12.93%), originating from 43 (35.83%) hotels, tested positive for Legionella (Legionella pneumophila serogroups 1, 2, 3, 6, 7, 8, 13, 14, 15 and non-pneumophila species (L. anisa, L. erythra, L. taurinensis, L. birminghamensis, L. rubrilucens). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for chlorine concentrations of less than 0.2 mg/L (R.R.: 54.78), star classification (<4) (R.R.: 4.75) and absence of Water Safety Plan implementation (R.R.: 3.96). High risk (≥104 CFU/L) was estimated for pool showers (16.42%), garden sprinklers (7.46%) and pool water (5.97%).
Collapse
|
6
|
Mouchtouri VA, Rudge JW. Legionnaires' Disease in Hotels and Passenger Ships: A Systematic Review of Evidence, Sources, and Contributing Factors. J Travel Med 2015. [PMID: 26220258 DOI: 10.1111/jtm.12225] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Travel-associated Legionnaires' disease (LD) is a serious problem, and hundreds of cases are reported every year among travelers who stayed at hotels, despite the efforts of international and governmental authorities and hotel operators to prevent additional cases. METHODS A systematic review of travel-associated LD events (cases, clusters, outbreaks) and of environmental studies of Legionella contamination in accommodation sites was conducted. Two databases were searched (PubMed and EMBASE). Data were extracted from 50 peer-reviewed articles that provided microbiological and epidemiological evidence for linking the accommodation sites with LD. The strength of evidence was classified as strong, possible, and probable. RESULTS Three of the 21 hotel-associated events identified and four of nine ship-associated events occurred repeatedly on the same site. Of 197 hotel-associated cases, 158 (80.2%) were linked to hotel cooling towers and/or potable water systems. Ship-associated cases were most commonly linked to hot tubs (59/83, 71.1%). Common contributing factors included inadequate disinfection, maintenance, and monitoring; water stagnation; poor temperature control; and poor ventilation. Across all 30 events, Legionella concentrations in suspected water sources were >10,000 cfu/L, <10,000 cfu/L, and unknown in 11, 3, and 13 events, respectively. In five events, Legionella was not detected only after repeated disinfections. In environmental studies, Legionella was detected in 81.1% of ferries (23/28) and 48.9% of hotels (587/1,200), while all 12 cruise ships examined were negative. CONCLUSIONS This review highlights the need for LD awareness strategies targeting operators of accommodation sites. Increased standardization of LD investigation and reporting, and more rigorous follow-up of LD events, would help generate stronger, more comparable evidence on LD sources, contributing factors, and control measure effectiveness.
Collapse
Affiliation(s)
- Varvara A Mouchtouri
- Department of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | - James W Rudge
- Communicable Diseases Policy Research Group, London School of Hygiene & Tropical Medicine, Bangkok Office, Mahidol University, Bangkok, Thailand
| |
Collapse
|
7
|
van Heijnsbergen E, Schalk JAC, Euser SM, Brandsema PS, den Boer JW, de Roda Husman AM. Confirmed and Potential Sources of Legionella Reviewed. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:4797-815. [PMID: 25774976 DOI: 10.1021/acs.est.5b00142] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Legionella bacteria are ubiquitous in natural matrices and man-made systems. However, it is not always clear if these reservoirs can act as source of infection resulting in cases of Legionnaires' disease. This review provides an overview of reservoirs of Legionella reported in the literature, other than drinking water distribution systems. Levels of evidence were developed to discriminate between potential and confirmed sources of Legionella. A total of 17 systems and matrices could be classified as confirmed sources of Legionella. Many other man-made systems or natural matrices were not classified as a confirmed source, since either no patients were linked to these reservoirs or the supporting evidence was weak. However, these systems or matrices could play an important role in the transmission of infectious Legionella bacteria; they might not yet be considered in source investigations, resulting in an underestimation of their importance. To optimize source investigations it is important to have knowledge about all the (potential) sources of Legionella. Further research is needed to unravel what the contribution is of each confirmed source, and possibly also potential sources, to the LD disease burden.
Collapse
Affiliation(s)
- Eri van Heijnsbergen
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
| | - Johanna A C Schalk
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
| | - Sjoerd M Euser
- ‡Regional Public Health Laboratory Kennemerland, Haarlem, Boerhaavelaan 26, 2035 RC Haarlem, The Netherlands
| | - Petra S Brandsema
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
| | - Jeroen W den Boer
- ‡Regional Public Health Laboratory Kennemerland, Haarlem, Boerhaavelaan 26, 2035 RC Haarlem, The Netherlands
| | - Ana Maria de Roda Husman
- †National Institute for Public Health and the Environment, A. van Leeuwenhoeklaan 9, 3721 MA Bilthoven, The Netherlands
- §Institute for Risk Assessment Sciences, Utrecht University, Yalelaan 2, 3584 CM Utrecht, The Netherlands
| |
Collapse
|
8
|
Abubakar I, Gautret P, Brunette GW, Blumberg L, Johnson D, Poumerol G, Memish ZA, Barbeschi M, Khan AS. Global perspectives for prevention of infectious diseases associated with mass gatherings. THE LANCET. INFECTIOUS DISEASES 2012; 12:66-74. [PMID: 22192131 DOI: 10.1016/s1473-3099(11)70246-8] [Citation(s) in RCA: 185] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
We assess risks of communicable diseases that are associated with mass gatherings (MGs), outline approaches to risk assessment and mitigation, and draw attention to some key challenges encountered by organisers and participants. Crowding and lack of sanitation at MGs can lead to the emergence of infectious diseases, and rapid population movement can spread them across the world. Many infections pose huge challenges to planners of MGs; however, these events also provide an opportunity to engage in public health action that will benefit host communities and the countries from which participants originate.
Collapse
|
9
|
Fragou K, Kokkinos P, Gogos C, Alamanos Y, Vantarakis A. Prevalence of Legionella spp. in water systems of hospitals and hotels in South Western Greece. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2011; 22:340-354. [PMID: 22149148 DOI: 10.1080/09603123.2011.643229] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The aim of the present study was to determine the prevalence of Legionella spp. in water systems of hospitals and hotels located in South Western Greece, to study the molecular epidemiology of the isolated strains and their possible association with bacterial contamination (total count and Pseudomonas aeruginosa), the water pH, and temperature. A prevalence survey for Legionella spp. by culturing techniques in water distribution systems of eight hospitals and nine hotels occurred in South Western Greece. Water sampling and microbiological analysis were carried out following the ISO methods. Legionella pneumophila was detected in 33% and 36% of the distribution systems of hospitals and hotels, respectively. Our survey results suggest a frequent prevalence of elevated concentrations of Legionella spp. in water systems of hospitals and hotels. Our investigation has confirmed the need to regularly monitor the microbiological condition of water systems in hospitals and hotels.
Collapse
Affiliation(s)
- K Fragou
- Department of Public Health, Medical School, University of Patras, Patras, Greece
| | | | | | | | | |
Collapse
|
10
|
Velonakis E, Karanika M, Mouchtouri V, Thanasias E, Katsiaflaka A, Vatopoulos A, Hadjichristodoulou C. Decreasing trend of Legionella isolation in a long-term microbial monitoring program in Greek hospitals. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2011; 22:197-209. [PMID: 22017573 DOI: 10.1080/09603123.2011.628644] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Legionnaires' disease is a known cause of severe pneumonia in a nosocomial setting. This study examined Legionella isolation in Greek hospitals. Water samples and swabs of showerheads from 41 hospitals were collected over a four-year period (2004-2007) from hot and cold water systems and cooling towers in Greece. In total, 1058 samples were examined for the presence of Legionella. From the hot water samples examined, 166 out of 607 (27.3%) were positive for Legionella, including 111 (18.3%) positive for Legionella pneumophila sg1 samples. The temperature of hot water samples less than 55°C was statistically significant, associated with Legionella spp. isolation (RR 4.01, 95%CI 2.33-6.92). Ten out of 17 (58.8%) hospital cooling towers required remedial actions due to Legionella colonization. Reemergence of Legionella spp. colonization was evident in more than half of the hospitals where frequent monitoring and appropriate risk assessment plans were absent or lacking. Hospitals that were monitored continuously over the study period presented a decreasing trend of Legionella colonization. Environmental risk assessment together with Legionella isolation should be enforced systematically in hospitals.
Collapse
Affiliation(s)
- Emanouil Velonakis
- Department of Microbiology, National School of Public Health, Athens, Greece
| | | | | | | | | | | | | |
Collapse
|
11
|
Napoli C, Fasano F, Iatta R, Barbuti G, Cuna T, Montagna MT. Legionella spp. and legionellosis in southeastern Italy: disease epidemiology and environmental surveillance in community and health care facilities. BMC Public Health 2010; 10:660. [PMID: 21044294 PMCID: PMC2988737 DOI: 10.1186/1471-2458-10-660] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2009] [Accepted: 11/02/2010] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Following the publication of the Italian Guidelines for the control and prevention of legionellosis an environmental and clinical surveillance has been carried out in Southeastern Italy. The aim of the study is to identify the risk factors for the disease, so allowing better programming of the necessary prevention measures. METHODS During the period January 2000 - December 2009 the environmental surveillance was carried out by water sampling of 129 health care facilities (73 public and 56 private hospitals) and 533 buildings within the community (63 private apartments, 305 hotels, 19 offices, 4 churches, 116 gyms, 3 swimming pools and 23 schools). Water sampling and microbiological analysis were carried out following the Italian Guidelines. From January 2005, all facilities were subject to risk analysis through the use of a standardized report; the results were classified as good (G), medium (M) and bad (B). As well, all the clinical surveillance forms for legionellosis, which must be compiled by physicians and sent to the Regional Centre for Epidemiology (OER), were analyzed. RESULTS Legionella spp. was found in 102 (79.1%) health care facilities and in 238 (44.7%) community buildings. The percentages for the contamination levels < 1,000, 1,000-10,000, > 10,000 cfu/L were respectively 33.1%, 53.4% and 13.5% for samples from health care facilities and 33.5%, 43.3% and 23.2% for samples from the community. Both in hospital and community environments, Legionella pneumophila serogroup (L. pn sg) 2-14 was the most frequently isolate (respectively 54.8% and 40.8% of positive samples), followed by L. pn sg 1 (respectively 31.3% and 33%). The study showed a significant association between M or B score at the risk analysis and Legionella spp. positive microbiological test results (p < 0.001). From clinical surveillance, during the period January 2001 - August 2009, 97 cases of legionellosis were reported to the OER: 88 of community origin and 9 nosocomial. The most frequent symptoms were: fever (93.8%), cough (70.1%), dyspnea (58.8%), shivering (56.7%). Radiological evidence of pneumonia was reported in 68%. The laboratory diagnostic methods used were: urinary antigen (54.3%), single antibody titer (19.8%), only seroconversion (11.1%), other diagnostic methods (14.8%). CONCLUSIONS Our experience suggests that risk analysis and environmental microbiological surveillance should be carried out more frequently to control the environmental spread of Legionella spp. Furthermore, the laboratory diagnosis of legionellosis cannot be excluded only on the basis of a single negative test: some patients were positive to only one of the diagnostic tests.
Collapse
Affiliation(s)
- Christian Napoli
- Department of Biomedical Science and Human Oncology - Hygiene section, University of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
- Legionella Reference Laboratory - Regional Centre for Epidemiology (OER), Apulia Italy, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Fabrizio Fasano
- Department of Biomedical Science and Human Oncology - Hygiene section, University of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Roberta Iatta
- Department of Biomedical Science and Human Oncology - Hygiene section, University of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Giovanna Barbuti
- Department of Biomedical Science and Human Oncology - Hygiene section, University of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Teresa Cuna
- Department of Biomedical Science and Human Oncology - Hygiene section, University of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
| | - Maria Teresa Montagna
- Department of Biomedical Science and Human Oncology - Hygiene section, University of Bari, Piazza G. Cesare 11, 70124 Bari, Italy
- Legionella Reference Laboratory - Regional Centre for Epidemiology (OER), Apulia Italy, Piazza G. Cesare 11, 70124 Bari, Italy
| |
Collapse
|
12
|
Mouchtouri VA, Goutziana G, Kremastinou J, Hadjichristodoulou C. Legionella species colonization in cooling towers: risk factors and assessment of control measures. Am J Infect Control 2010; 38:50-5. [PMID: 19699013 DOI: 10.1016/j.ajic.2009.04.285] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2009] [Revised: 04/16/2009] [Accepted: 04/20/2009] [Indexed: 11/19/2022]
Abstract
BACKGROUND Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. METHODS A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. RESULTS Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was < 0.5 mg/L (RR = 2.23; P = .01), and with total plate count (P =.001). Colonization was negatively associated with chemical disinfection (RR = 0.2; P = .0003) and with the presence of a risk assessment and management plan (RR = 0.12; P = .0005). A statistically significant higher age (P =.01) was found in legionellae-positive cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). CONCLUSIONS Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and management plan. Water chlorination effectively reduces legionellae contamination. Proper training of cooling tower operators is paramount.
Collapse
Affiliation(s)
- Varvara A Mouchtouri
- Department of Hygiene and Epidemiology, Medical School, University of Thessaly, Larissa, Greece
| | | | | | | |
Collapse
|
13
|
Goutziana G, Mouchtouri VA, Karanika M, Kavagias A, Stathakis NE, Gourgoulianis K, Kremastinou J, Hadjichristodoulou C. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries. BMC Public Health 2008; 8:390. [PMID: 19025638 PMCID: PMC2605755 DOI: 10.1186/1471-2458-8-390] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2008] [Accepted: 11/24/2008] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. METHODS Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. RESULTS The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp. CONCLUSION WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members.
Collapse
Affiliation(s)
- Georgia Goutziana
- Department of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | - Varvara A Mouchtouri
- Department of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa, Greece
- National School of Public Health, Department of Public and Administrative Health, Athens, Greece
| | - Maria Karanika
- Department of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | | | - Nikolaos E Stathakis
- Department of Internal Medicine, Faculty of Medicine, University of Thessaly, Larissa, Greece
| | - Kostantinos Gourgoulianis
- Department of Respiratory Medicine, Faculty of Medicine, University of Thessaly, University Hospital of Larissa, Larissa, Greece
| | - Jenny Kremastinou
- National School of Public Health, Department of Public and Administrative Health, Athens, Greece
| | | |
Collapse
|
14
|
Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species. Am J Infect Control 2007; 35:623-7. [PMID: 17980243 DOI: 10.1016/j.ajic.2007.01.002] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2006] [Revised: 01/16/2007] [Accepted: 01/17/2007] [Indexed: 11/21/2022]
Abstract
Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.
Collapse
|
15
|
Mouchtouri V, Velonakis E, Tsakalof A, Kapoula C, Goutziana G, Vatopoulos A, Kremastinou J, Hadjichristodoulou C. Risk factors for contamination of hotel water distribution systems by Legionella species. Appl Environ Microbiol 2007; 73:1489-92. [PMID: 17261527 PMCID: PMC1828777 DOI: 10.1128/aem.02191-06] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
The Legionella colonization frequency at 385 Greek hotel hot and cold water distribution systems was 20.8%. Legionella contamination was associated with the presence of an oil heater (odds ratio [OR]=2.04, 95% confidence interval [CI]=1.12 to 3.70), with the sample temperature (OR=0.26, 95% CI=0.1 to 0.5), with seasonal operation (OR=3.23, 95% CI=1.52 to 6.87), and with the presence of an independent disinfection system (OR=0.30, 95% CI=0.15 to 0.62). The same water temperatures, free-chlorine levels, and pHs differently affect the survival of various Legionella spp.
Collapse
Affiliation(s)
- Varvara Mouchtouri
- Department of Hygiene and Epidemiology, Faculty of Medicine, University of Thessaly, 22 Papakiriazi Str., Larissa 41222, Greece
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Hadjichristodoulou C, Mouchtouri V, Vaitsi V, Kapoula C, Vousoureli A, Kalivitis I, Chervoni J, Papastergiou P, Vasilogiannakopoulos A, Daniilidis VD, Kremastinou J. Management of environmental health issues for the 2004 Athens Olympic Games: is enhanced integrated environmental health surveillance needed in every day routine operation? BMC Public Health 2006; 6:306. [PMID: 17176469 PMCID: PMC1764887 DOI: 10.1186/1471-2458-6-306] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2006] [Accepted: 12/18/2006] [Indexed: 11/30/2022] Open
Abstract
Background Management of environmental health issues is an integral part of public health systems. An active integrated environmental health surveillance and response system was developed for the Athens Olympics to monitor and prevent exposure to environmental hazards. The potential for permanent implementation of the program was examined. Methods The environmental health surveillance and response system included standardization, computerization and electronic transmission of data concerning environmental inspections of 17 site categories (restaurants, swimming pools etc) of public health interest, drinking and recreational water examinations and suggested corrective actions. The Olympic Planning Unit integrated and centrally managed data from 13 public health agencies, recommended, supervised and coordinated prompt corrective actions. Methods used to test the effectiveness of the program were the assessment of water quality test and inspection results trends over time using linear regression and epidemiological surveillance findings. Results Between January 2003 and September the 30th, 2004, 196 inspectors conducted 8562 inspections, collected 5024 water samples and recommended 17 027 corrective actions. In 10 cruise ships used as floating hotels inspectors conducted 10 full inspections, 2 re-inspections, and 27 follow-up inspections. Unsatisfactory inspection results (r = 0.44, p < 0.0001) and positive water quality tests (r = 0.39, p < 0.001) presented an overall decrease trend over time. In August, 2003, an outbreak of salmonellosis was linked to a hotel restaurant which accommodated athletes during a test event. Conclusion Lessons learned for future events include timely implementation and installation of communication processes, and rapid and coordinated response to unsatisfactory inspection results. Routine national programs need to adopt enhanced environmental health surveillance aimed at public health decision-making, but with a different perspective.
Collapse
Affiliation(s)
- Christos Hadjichristodoulou
- University of Thessaly, Faculty of Medicine, Department of Hygiene and Epidemiology, Larissa, Greece
- National School of Public Health, Olympic Planning Unit, Athens, Greece
| | - Varvara Mouchtouri
- University of Thessaly, Faculty of Medicine, Department of Hygiene and Epidemiology, Larissa, Greece
- National School of Public Health, Olympic Planning Unit, Athens, Greece
| | - Vasiliki Vaitsi
- National School of Public Health, Olympic Planning Unit, Athens, Greece
| | - Christina Kapoula
- University of Thessaly, Faculty of Medicine, Department of Hygiene and Epidemiology, Larissa, Greece
- National School of Public Health, Olympic Planning Unit, Athens, Greece
| | | | | | - Julia Chervoni
- US Centers for Disease Control and Prevention's (CDC) Vessel Sanitation Program (VSP), Atlanta, USA
| | - Panagiotis Papastergiou
- University of Thessaly, Faculty of Medicine, Department of Hygiene and Epidemiology, Larissa, Greece
| | | | | | - Jenny Kremastinou
- National School of Public Health, Olympic Planning Unit, Athens, Greece
| |
Collapse
|