1
|
Doyle MG, Chugunova M, Roche SL, Keener JP. Lumped parameter models for two-ventricle and healthy and failing extracardiac Fontan circulations. MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA 2021; 38:442-466. [PMID: 34534322 DOI: 10.1093/imammb/dqab012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 06/14/2021] [Accepted: 08/26/2021] [Indexed: 11/13/2022]
Abstract
Fontan circulations are surgical strategies to treat infants born with single ventricle physiology. Clinical and mathematical definitions of Fontan failure are lacking, and understanding is needed of parameters indicative of declining physiologies. Our objective is to develop lumped parameter models of two-ventricle and single-ventricle circulations. These models, their mathematical formulations and a proof of existence of periodic solutions are presented. Sensitivity analyses are performed to identify key parameters. Systemic venous and systolic left ventricular compliances and systemic capillary and pulmonary venous resistances are identified as key parameters. Our models serve as a framework to study the differences between two-ventricle and single-ventricle physiologies and healthy and failing Fontan circulations.
Collapse
Affiliation(s)
- Matthew G Doyle
- Department of Mechanical and Industrial Engineering and Division of Vascular Surgery, University of Toronto, Toronto, ON M5S 1A1, Canada
| | - Marina Chugunova
- Institute of Mathematical Sciences, Claremont Graduate University, Claremont, CA 91711, USA
| | - S Lucy Roche
- Division of Cardiology, Peter Munk Cardiac Centre, University Health Network, Toronto, ON M5S 1A1, Canada
| | - James P Keener
- Department of Mathematics, University of Utah, Salt Lake City, UT 84112, USA
| |
Collapse
|
2
|
Heart beat but not respiration is the main driving force of the systemic venous return in the Fontan circulation. Sci Rep 2019; 9:2034. [PMID: 30765829 PMCID: PMC6376003 DOI: 10.1038/s41598-019-38848-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2018] [Accepted: 01/11/2019] [Indexed: 01/05/2023] Open
Abstract
The Fontan procedure provides relief from cyanosis in patients with univentricular hearts. A major clinical unmet need is to understand whether the venous flow patterns of the Fontan circulation lead to the development of congestive hepatopathy and other life-threatening complications. Currently, there is no consensus on whether heart beat or respiration is the main driving force of venous return and which one affects the periodic flow changes for the most (i. e., pulsatility). The present study, for the first time, quantified respiratory and cardiac components of the venous flow in the inferior vena cava (IVC) of 14 Fontan patients and 11 normal controls using a novel approach (“physio-matrix”). We found that in contrast to the normal controls, respiration in Fontan patients had a significant effect on venous flow pulsatility, and the ratio of respiration-dependent to the cardiac-dependent pulsatility was positively associated with the retrograde flow. Nevertheless, the main driving force of net IVC flow was the heart beat and not respiration. The separate analysis of the effects of respiration and heart beat provides new insights into the abnormal venous return patterns that may be responsible for adverse effects on liver and bowel of the patients with Fontan circulation.
Collapse
|
3
|
Tang E, Wei ZA, Trusty PM, Whitehead KK, Mirabella L, Veneziani A, Fogel MA, Yoganathan AP. The effect of respiration-driven flow waveforms on hemodynamic metrics used in Fontan surgical planning. J Biomech 2018; 82:87-95. [PMID: 30414631 DOI: 10.1016/j.jbiomech.2018.10.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 10/12/2018] [Accepted: 10/17/2018] [Indexed: 10/28/2022]
Abstract
OBJECTIVE Poor total cavopulmonary connection (TCPC) hemodynamics have been hypothesized to be associated with long-term complications in Fontan patients. Image-based Fontan surgical planning has shown great potential as a clinical tool because it can pre-operatively evaluate patient-specific hemodynamics. Current surgical planning paradigms commonly utilize cardiac-gated phase contrast magnetic resonance (MR) imaging to acquire vessel flows. These acquisitions are often taken under breath-held (BH) conditions and ignore the effect of respiration on blood flow waveforms. This study investigates the effect of respiration-driven flow waveforms on patient-specific hemodynamics using real-time MR acquisitions. METHODS Patient-specific TCPCs were reconstructed from cardiovascular MR images. Real-time phase contrast MR images were acquired under both free-breathing (FB) and breath-held conditions for 9 patients. Numerical simulations were employed to assess flow structures and hemodynamics used in Fontan surgical planning including hepatic flow distribution (HFD) and indexed power loss (iPL), which were then compared between FB and BH conditions. RESULTS Differences in TCPC flow structures between FB and BH conditions were observed throughout the respiratory cycle. However, the average differences (BH - FB values for each patient, which are then averaged) in iPL and HFD between these conditions were 0.002 ± 0.011 (p = 0.40) and 1 ± 3% (p = 0.28), respectively, indicating no significant difference in clinically important hemodynamic metrics. CONCLUSIONS Respiration affects blood flow waveforms and flow structures, but might not significantly influence the values of iPL or HFD. Therefore, breath-held MR acquisition can be adequate for Fontan surgical planning when focusing on iPL and HFD.
Collapse
Affiliation(s)
- Elaine Tang
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Zhenglun Alan Wei
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA, USA
| | - Phillip M Trusty
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA, USA
| | - Kevin K Whitehead
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Lucia Mirabella
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA, USA
| | - Alessandro Veneziani
- Department of Mathematics and Computer Science, Emory University, Atlanta, GA, USA
| | - Mark A Fogel
- Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
| | - Ajit P Yoganathan
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, USA; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA, USA.
| |
Collapse
|
4
|
Wei ZA, Trusty PM, Tree M, Haggerty CM, Tang E, Fogel M, Yoganathan AP. Can time-averaged flow boundary conditions be used to meet the clinical timeline for Fontan surgical planning? J Biomech 2016; 50:172-179. [PMID: 27855985 DOI: 10.1016/j.jbiomech.2016.11.025] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Accepted: 11/02/2016] [Indexed: 11/15/2022]
Abstract
Cardiovascular simulations have great potential as a clinical tool for planning and evaluating patient-specific treatment strategies for those suffering from congenital heart diseases, specifically Fontan patients. However, several bottlenecks have delayed wider deployment of the simulations for clinical use; the main obstacle is simulation cost. Currently, time-averaged clinical flow measurements are utilized as numerical boundary conditions (BCs) in order to reduce the computational power and time needed to offer surgical planning within a clinical time frame. Nevertheless, pulsatile blood flow is observed in vivo, and its significant impact on numerical simulations has been demonstrated. Therefore, it is imperative to carry out a comprehensive study analyzing the sensitivity of using time-averaged BCs. In this study, sensitivity is evaluated based on the discrepancies between hemodynamic metrics calculated using time-averaged and pulsatile BCs; smaller discrepancies indicate less sensitivity. The current study incorporates a comparison between 3D patient-specific CFD simulations using both the time-averaged and pulsatile BCs for 101 Fontan patients. The sensitivity analysis involves two clinically important hemodynamic metrics: hepatic flow distribution (HFD) and indexed power loss (iPL). Paired demographic group comparisons revealed that HFD sensitivity is significantly different between single and bilateral superior vena cava cohorts but no other demographic discrepancies were observed for HFD or iPL. Multivariate regression analyses show that the best predictors for sensitivity involve flow pulsatilities, time-averaged flow rates, and geometric characteristics of the Fontan connection. These predictors provide patient-specific guidelines to determine the effectiveness of analyzing patient-specific surgical options with time-averaged BCs within a clinical time frame.
Collapse
Affiliation(s)
- Zhenglun Alan Wei
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle, Suite 232, Atlanta, GA 30313-2412, USA
| | - Phillip M Trusty
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle, Suite 232, Atlanta, GA 30313-2412, USA
| | - Mike Tree
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | | | - Elaine Tang
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Mark Fogel
- Division of Cardiology, Children׳s Hospital of Philadelphia, Philadelphia, PA, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 387 Technology Circle, Suite 232, Atlanta, GA 30313-2412, USA.
| |
Collapse
|
5
|
Mock circulatory system of the Fontan circulation to study respiration effects on venous flow behavior. ASAIO J 2013; 59:253-60. [PMID: 23644612 DOI: 10.1097/mat.0b013e318288a2ab] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
We describe an in vitro model of the Fontan circulation with respiration to study subdiaphragmatic venous flow behavior. The venous and arterial connections of a total cavopulmonary connection (TCPC) test section were coupled with a physical lumped parameter (LP) model of the circulation. Intrathoracic and subdiaphragmatic pressure changes associated with normal breathing were applied. This system was tuned for two patients (5 years, 0.67 m2; 10 years, 1.2 m2) to physiological values. System function was verified by comparison to the analytical model on which it was based and by consistency with published clinical measurements. Overall, subdiaphragmatic venous flow was influenced by respiration. Flow within the arteries and veins increased during inspiration but decreased during expiration, with retrograde flow in the inferior venous territories. System pressures and flows showed close agreement with the analytical LP model (p < 0.05). The ratio of the flow rates occurring during inspiration to expiration were within the clinical range of values reported elsewhere. The approach used to set up and control the model was effective and provided reasonable comparisons with clinical data.
Collapse
|
6
|
Hong H, Dur O, Zhang H, Zhu Z, Pekkan K, Liu J. Fontan conversion templates: patient-specific hemodynamic performance of the lateral tunnel versus the intraatrial conduit with fenestration. Pediatr Cardiol 2013; 34:1447-54. [PMID: 23475255 DOI: 10.1007/s00246-013-0669-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Accepted: 02/11/2013] [Indexed: 11/25/2022]
Abstract
Intraatrial-conduit Fontan is considered a modification of both extracardiac and lateral-tunnel Fontan. In this study, the patient-specific hemodynamic performance of intraatrial-conduit and lateral-tunnel Fontan with fenestration, considered as conversion templates, was investigated based on the authors' patient cohort. Pulsatile computational fluid dynamics simulations were performed using patient-specific models of intraatrial-conduit and lateral-tunnel Fontan patients. Real-time "simultaneous" inferior and superior vena cava, pulmonary artery, and fenestration flow waveforms were acquired from ultrasound. Multiple hemodynamic performance indices were investigated, with particular focus on evaluation of the pulsatile flow performance. Power loss inside the lateral-tunnel Fontan appeared to be significantly higher than with the intraatrial-conduit Fontan for patient-specific cardiac output and normalized connection size. Inclusion of the 4-mm fenestration at a 0.24 L/min mean flow resulted in a lower cavopulmonary pressure gradient and less time-averaged power loss for both Fontan connections. Flow structures within the intraatrial conduit were notability more uniform than within the lateral tunnel. Hepatic flow majorly favored the left lung in both surgical connections: conversion from lateral-tunnel to intraatrial-conduit Fontan resulted in better hemodynamics with less power loss, a lower pressure gradient, and fewer stagnant flow zones along the conduit. This patient-specific computational case study demonstrated superior hemodynamics of intraatrial-conduit Fontan over those of lateral-tunnel Fontan with or without fenestration and improved performance after conversion of the lateral tunnel to the intraatrial conduit. The geometry-specific effect of the nonuniform hepatic flow distribution may motivate new rationales for the surgical design.
Collapse
Affiliation(s)
- Haifa Hong
- The Cardiothoracic Surgery Department, Shanghai Children's Medical Center, Medical School Shanghai Jiaotong University, 1678 Dongfang Road, Shanghai 200127, China
| | | | | | | | | | | |
Collapse
|
7
|
Khiabani RH, Restrepo M, Tang E, De Zélicourt D, Sotiropoulos F, Fogel M, Yoganathan AP. Effect of flow pulsatility on modeling the hemodynamics in the total cavopulmonary connection. J Biomech 2012; 45:2376-81. [PMID: 22841650 DOI: 10.1016/j.jbiomech.2012.07.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 07/05/2012] [Accepted: 07/05/2012] [Indexed: 11/17/2022]
Abstract
Total cavopulmonary connection is the result of a series of palliative surgical repairs performed on patients with single ventricle heart defects. The resulting anatomy has complex and unsteady hemodynamics characterized by flow mixing and flow separation. Although varying degrees of flow pulsatility have been observed in vivo, non-pulsatile (time-averaged) boundary conditions have traditionally been assumed in hemodynamic modeling, and only recently have pulsatile conditions been incorporated without completely characterizing their effect or importance. In this study, 3D numerical simulations with both pulsatile and non-pulsatile boundary conditions were performed for 24 patients with different anatomies and flow boundary conditions from Georgia Tech database. Flow structures, energy dissipation rates and pressure drops were compared under rest and simulated exercise conditions. It was found that flow pulsatility is the primary factor in determining the appropriate choice of boundary conditions, whereas the anatomic configuration and cardiac output had secondary effects. Results show that the hemodynamics can be strongly influenced by the presence of pulsatile flow. However, there was a minimum pulsatility threshold, identified by defining a weighted pulsatility index (wPI), above which the influence was significant. It was shown that when wPI<30%, the relative error in hemodynamic predictions using time-averaged boundary conditions was less than 10% compared to pulsatile simulations. In addition, when wPI<50, the relative error was less than 20%. A correlation was introduced to relate wPI to the relative error in predicting the flow metrics with non-pulsatile flow conditions.
Collapse
Affiliation(s)
- Reza H Khiabani
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, 30332-0535, USA
| | | | | | | | | | | | | |
Collapse
|
8
|
Lara M, Chen CY, Mannor P, Dur O, Menon PG, Yoganathan AP, Pekkan K. Hemodynamics of the Hepatic Venous Three-Vessel Confluences Using Particle Image Velocimetry. Ann Biomed Eng 2011; 39:2398-416. [DOI: 10.1007/s10439-011-0326-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2010] [Accepted: 05/10/2011] [Indexed: 11/27/2022]
|