Peters-Clarke TM, Coon JJ, Riley NM. Instrumentation at the Leading Edge of Proteomics. Anal Chem 2024; 96:7976-8010. [PMID: 38738990 DOI: 10.1021/acs.analchem.3c04497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Affiliation(s)
- Trenton M Peters-Clarke
- Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
- Department of Biomolecular Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
| | - Joshua J Coon
- Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
- Department of Biomolecular Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States
- Morgridge Institute for Research, Madison, Wisconsin 53715, United States
| | - Nicholas M Riley
- Department of Chemistry, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
2
|
Serrano LR, Peters-Clarke TM, Arrey TN, Damoc E, Robinson ML, Lancaster NM, Shishkova E, Moss C, Pashkova A, Sinitcyn P, Brademan DR, Quarmby ST, Peterson AC, Zeller M, Hermanson D, Stewart H, Hock C, Makarov A, Zabrouskov V, Coon JJ. The One Hour Human Proteome. Mol Cell Proteomics 2024; 23:100760. [PMID: 38579929 PMCID: PMC11103439 DOI: 10.1016/j.mcpro.2024.100760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/23/2024] [Accepted: 03/29/2024] [Indexed: 04/07/2024] Open
Abstract
We describe deep analysis of the human proteome in less than 1 h. We achieve this expedited proteome characterization by leveraging state-of-the-art sample preparation, chromatographic separations, and data analysis tools, and by using the new Orbitrap Astral mass spectrometer equipped with a quadrupole mass filter, a high-field Orbitrap mass analyzer, and an asymmetric track lossless (Astral) mass analyzer. The system offers high tandem mass spectrometry acquisition speed of 200 Hz and detects hundreds of peptide sequences per second within data-independent acquisition or data-dependent acquisition modes of operation. The fast-switching capabilities of the new quadrupole complement the sensitivity and fast ion scanning of the Astral analyzer to enable narrow-bin data-independent analysis methods. Over a 30-min active chromatographic method consuming a total analysis time of 56 min, the Q-Orbitrap-Astral hybrid MS collects an average of 4319 MS1 scans and 438,062 tandem mass spectrometry scans per run, producing 235,916 peptide sequences (1% false discovery rate). On average, each 30-min analysis achieved detection of 10,411 protein groups (1% false discovery rate). We conclude, with these results and alongside other recent reports, that the 1-h human proteome is within reach.
Collapse
Affiliation(s)
- Lia R Serrano
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Trenton M Peters-Clarke
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | - Eugen Damoc
- Thermo Fisher Scientific GmbH, Bremen, Germany
| | - Margaret Lea Robinson
- Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Noah M Lancaster
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Evgenia Shishkova
- Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; National Center for Quantitative Biology of Complex Systems, Madison, Wisconsin, USA
| | - Corinne Moss
- Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | | | - Pavel Sinitcyn
- Morgridge Institute for Research, Madison, Wisconsin, USA
| | | | - Scott T Quarmby
- Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; National Center for Quantitative Biology of Complex Systems, Madison, Wisconsin, USA
| | | | | | | | | | | | | | | | - Joshua J Coon
- Department of Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin, USA; National Center for Quantitative Biology of Complex Systems, Madison, Wisconsin, USA; Morgridge Institute for Research, Madison, Wisconsin, USA.
| |
Collapse
|
3
|
Stewart H, Grinfeld D, Petzoldt J, Hagedorn B, Skoblin M, Makarov A, Hock C. Crowd control of ions in the Astral analyzer. JOURNAL OF MASS SPECTROMETRY : JMS 2024; 59:e5006. [PMID: 38501497 DOI: 10.1002/jms.5006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/19/2024] [Accepted: 01/23/2024] [Indexed: 03/20/2024]
Abstract
Space charge effects are the Achilles' heel of all high-resolution ion optical devices. In time-of-flight mass analyzers, these may manifest as reduction of resolving power, mass measurement shift, peak coalescence, and/or transmission losses, while highly sensitive modern ion sources and injection devices ensure that such limits are easily exceeded. Space charge effects have been investigated, by experiment and simulation study, for the astral multi-reflection analyzer, incorporating ion focusing via a pair of converging ion mirrors, and fed by a pulsed extraction ion trap. Major factors were identified as the resonant effect between ~103 ions of similar m/z in-flight and the expansion of trapped packets of ~104-5 ions prior to extraction. Optimum operation and compensated ion mirror calibration strategies were then generated and described based on these findings.
Collapse
|
4
|
Stewart H, Grinfeld D, Wagner A, Kholomeev A, Biel M, Giannakopulos A, Makarov A, Hock C. A Conjoined Rectilinear Collision Cell and Pulsed Extraction Ion Trap with Auxiliary DC Electrodes. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:74-81. [PMID: 37925680 PMCID: PMC10767742 DOI: 10.1021/jasms.3c00311] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/09/2023] [Accepted: 10/13/2023] [Indexed: 11/07/2023]
Abstract
Ion traps are routinely directly coupled to mass analyzers, where they serve to suitably cool and shape an ion population prior to pulsed extraction into the analyzer proper. Such devices benefit from high duty cycle and transmission but suffer slow ion processing times caused by a compromise in the buffer gas pressure range that suitably dampens the ion kinetic energy without causing excessive scatter during extraction or within the analyzer. A rectilinear RF quadrupole ion trap has been characterized, conjoining a pressurized collision region with a pumped extraction region, and an unbroken RF interface for seamless ion transfer between them. Auxiliary electrodes mounted between the RF electrodes provide DC voltage gradients that serve to both guide ions through the device and position them at the extraction slot. The influence of the auxiliary DC upon the trapping RF field was measured, and suitable parameters were defined. A mode of operation was developed that allowed parallel processing of ions in both regions, enabling a repetition rate of 200 Hz when the device was coupled to a high-resolution accurate-mass analyzer.
Collapse
Affiliation(s)
- Hamish Stewart
- Thermo Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Dmitry Grinfeld
- Thermo Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Alexander Wagner
- Thermo Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | - Matthias Biel
- Thermo Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | - Alexander Makarov
- Thermo Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Christian Hock
- Thermo Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| |
Collapse
|
5
|
Thukral M, Allen AE, Petras D. Progress and challenges in exploring aquatic microbial communities using non-targeted metabolomics. THE ISME JOURNAL 2023; 17:2147-2159. [PMID: 37857709 PMCID: PMC10689791 DOI: 10.1038/s41396-023-01532-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 09/27/2023] [Accepted: 10/02/2023] [Indexed: 10/21/2023]
Abstract
Advances in bioanalytical technologies are constantly expanding our insights into complex ecosystems. Here, we highlight strategies and applications that make use of non-targeted metabolomics methods in aquatic chemical ecology research and discuss opportunities and remaining challenges of mass spectrometry-based methods to broaden our understanding of environmental systems.
Collapse
Affiliation(s)
- Monica Thukral
- University of California San Diego, Scripps Institution of Oceanography, La Jolla, CA, USA
- J. Craig Venter Institute, Microbial and Environmental Genomics Group, La Jolla, CA, USA
| | - Andrew E Allen
- University of California San Diego, Scripps Institution of Oceanography, La Jolla, CA, USA
- J. Craig Venter Institute, Microbial and Environmental Genomics Group, La Jolla, CA, USA
| | - Daniel Petras
- University of Tuebingen, CMFI Cluster of Excellence, Tuebingen, Germany.
- University of California Riverside, Department of Biochemistry, Riverside, CA, USA.
| |
Collapse
|
6
|
Stewart HI, Grinfeld D, Giannakopulos A, Petzoldt J, Shanley T, Garland M, Denisov E, Peterson AC, Damoc E, Zeller M, Arrey TN, Pashkova A, Renuse S, Hakimi A, Kühn A, Biel M, Kreutzmann A, Hagedorn B, Colonius I, Schütz A, Stefes A, Dwivedi A, Mourad D, Hoek M, Reitemeier B, Cochems P, Kholomeev A, Ostermann R, Quiring G, Ochmann M, Möhring S, Wagner A, Petker A, Kanngiesser S, Wiedemeyer M, Balschun W, Hermanson D, Zabrouskov V, Makarov AA, Hock C. Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis. Anal Chem 2023; 95:15656-15664. [PMID: 37815927 PMCID: PMC10603608 DOI: 10.1021/acs.analchem.3c02856] [Citation(s) in RCA: 33] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 09/25/2023] [Indexed: 10/12/2023]
Abstract
The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.
Collapse
Affiliation(s)
- Hamish I. Stewart
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Dmitry Grinfeld
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | - Johannes Petzoldt
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Toby Shanley
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Matthew Garland
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Eduard Denisov
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | - Eugen Damoc
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Martin Zeller
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Tabiwang N. Arrey
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Anna Pashkova
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Santosh Renuse
- Thermo
Fisher Scientific, 355
River Oaks Pkwy, San Jose, California 95134, United States
| | - Amirmansoor Hakimi
- Thermo
Fisher Scientific, 355
River Oaks Pkwy, San Jose, California 95134, United States
| | - Andreas Kühn
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Matthias Biel
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Arne Kreutzmann
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Bernd Hagedorn
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Immo Colonius
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Adrian Schütz
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Arne Stefes
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Ankit Dwivedi
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Daniel Mourad
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Max Hoek
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | - Philipp Cochems
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
- Thermo
Fisher Scientific, 355
River Oaks Pkwy, San Jose, California 95134, United States
| | | | - Robert Ostermann
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Gregor Quiring
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | - Sascha Möhring
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Alexander Wagner
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - André Petker
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | | | | | - Wilko Balschun
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| | - Daniel Hermanson
- Thermo
Fisher Scientific, 355
River Oaks Pkwy, San Jose, California 95134, United States
| | - Vlad Zabrouskov
- Thermo
Fisher Scientific, 355
River Oaks Pkwy, San Jose, California 95134, United States
| | | | - Christian Hock
- Thermo
Fisher Scientific, 11 Hannah-Kunath Str., 28199 Bremen, Germany
| |
Collapse
|
7
|
Kaczmarek M, Zhang N, Buzhansky L, Gilead S, Gazit E. Optimization Strategies for Mass Spectrometry-Based Untargeted Metabolomics Analysis of Small Polar Molecules in Human Plasma. Metabolites 2023; 13:923. [PMID: 37623867 PMCID: PMC10456887 DOI: 10.3390/metabo13080923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 07/23/2023] [Accepted: 08/03/2023] [Indexed: 08/26/2023] Open
Abstract
The untargeted approach to mass spectrometry-based metabolomics has a wide potential to investigate health and disease states, identify new biomarkers for diseases, and elucidate metabolic pathways. All this holds great promise for many applications in biological and chemical research. However, the complexity of instrumental parameters on advanced hybrid mass spectrometers can make the optimization of the analytical method immensely challenging. Here, we report a strategy to optimize the selected settings of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for untargeted metabolomics studies of human plasma, as a sample matrix. Specifically, we evaluated the effects of the reconstitution solvent in the sample preparation procedure, the injection volume employed, and different mass spectrometry-related operating parameters including mass range, the number of data-dependent fragmentation scans, collision energy mode, duration of dynamic exclusion time, and mass resolution settings on the metabolomics data quality and output. This study highlights key instrumental variables influencing the detection of metabolites along with suggested settings for the IQ-X tribrid system and proposes a new methodological framework to ensure increased metabolome coverage.
Collapse
Affiliation(s)
- Michał Kaczmarek
- Division of Metabolite Medicine, Blavatnik Center for Drug Discovery, Tel Aviv University, Tel Aviv 69978, Israel; (N.Z.); (L.B.); (S.G.); (E.G.)
| | - Nanyun Zhang
- Division of Metabolite Medicine, Blavatnik Center for Drug Discovery, Tel Aviv University, Tel Aviv 69978, Israel; (N.Z.); (L.B.); (S.G.); (E.G.)
| | - Ludmila Buzhansky
- Division of Metabolite Medicine, Blavatnik Center for Drug Discovery, Tel Aviv University, Tel Aviv 69978, Israel; (N.Z.); (L.B.); (S.G.); (E.G.)
| | - Sharon Gilead
- Division of Metabolite Medicine, Blavatnik Center for Drug Discovery, Tel Aviv University, Tel Aviv 69978, Israel; (N.Z.); (L.B.); (S.G.); (E.G.)
| | - Ehud Gazit
- Division of Metabolite Medicine, Blavatnik Center for Drug Discovery, Tel Aviv University, Tel Aviv 69978, Israel; (N.Z.); (L.B.); (S.G.); (E.G.)
- The Shmunis School of Biomedicine and Cancer Research, Tel Aviv University, Tel Aviv 69978, Israel
| |
Collapse
|
8
|
Deschamps E, Calabrese V, Schmitz I, Hubert-Roux M, Castagnos D, Afonso C. Advances in Ultra-High-Resolution Mass Spectrometry for Pharmaceutical Analysis. Molecules 2023; 28:molecules28052061. [PMID: 36903305 PMCID: PMC10003995 DOI: 10.3390/molecules28052061] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/16/2023] [Accepted: 02/19/2023] [Indexed: 02/25/2023] Open
Abstract
Pharmaceutical analysis refers to an area of analytical chemistry that deals with active compounds either by themselves (drug substance) or when formulated with excipients (drug product). In a less simplistic way, it can be defined as a complex science involving various disciplines, e.g., drug development, pharmacokinetics, drug metabolism, tissue distribution studies, and environmental contamination analyses. As such, the pharmaceutical analysis covers drug development to its impact on health and the environment. Moreover, due to the need for safe and effective medications, the pharmaceutical industry is one of the most heavily regulated sectors of the global economy. For this reason, powerful analytical instrumentation and efficient methods are required. In the last decades, mass spectrometry has been increasingly used in pharmaceutical analysis both for research aims and routine quality controls. Among different instrumental setups, ultra-high-resolution mass spectrometry with Fourier transform instruments, i.e., Fourier transform ion cyclotron resonance (FTICR) and Orbitrap, gives access to valuable molecular information for pharmaceutical analysis. In fact, thanks to their high resolving power, mass accuracy, and dynamic range, reliable molecular formula assignments or trace analysis in complex mixtures can be obtained. This review summarizes the principles of the two main types of Fourier transform mass spectrometers, and it highlights applications, developments, and future perspectives in pharmaceutical analysis.
Collapse
Affiliation(s)
- Estelle Deschamps
- Normandie Univ, COBRA, UMR 6014 and FR 3038, Université de Rouen, INSA de Rouen, CNRS, IRCOF, 1 rue Tesnières, CEDEX, 76821 Mont-Saint-Aignan, France
- ORIL Industrie, Servier Group, 13 r Auguste Desgenétais, 76210 Bolbec, France
| | - Valentina Calabrese
- Normandie Univ, COBRA, UMR 6014 and FR 3038, Université de Rouen, INSA de Rouen, CNRS, IRCOF, 1 rue Tesnières, CEDEX, 76821 Mont-Saint-Aignan, France
- Université de Lyon, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, CNRS UMR 5280, 5 Rue de La Doua, F-69100 Villeurbanne, France
| | - Isabelle Schmitz
- Normandie Univ, COBRA, UMR 6014 and FR 3038, Université de Rouen, INSA de Rouen, CNRS, IRCOF, 1 rue Tesnières, CEDEX, 76821 Mont-Saint-Aignan, France
| | - Marie Hubert-Roux
- Normandie Univ, COBRA, UMR 6014 and FR 3038, Université de Rouen, INSA de Rouen, CNRS, IRCOF, 1 rue Tesnières, CEDEX, 76821 Mont-Saint-Aignan, France
| | - Denis Castagnos
- ORIL Industrie, Servier Group, 13 r Auguste Desgenétais, 76210 Bolbec, France
| | - Carlos Afonso
- Normandie Univ, COBRA, UMR 6014 and FR 3038, Université de Rouen, INSA de Rouen, CNRS, IRCOF, 1 rue Tesnières, CEDEX, 76821 Mont-Saint-Aignan, France
- Correspondence:
| |
Collapse
|
9
|
Chen CY, Li YH, Li Z, Lee MR. Characterization of effective phytochemicals in traditional Chinese medicine by mass spectrometry. MASS SPECTROMETRY REVIEWS 2022:e21782. [PMID: 35638257 DOI: 10.1002/mas.21782] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 11/23/2021] [Accepted: 04/08/2022] [Indexed: 06/15/2023]
Abstract
Traditional Chinese medicines (TCMs) have been widely used in clinical and healthcare applications around the world. The characterization of the phytochemical components in TCMs is very important for studying the therapeutic mechanism of TCMs. In the analysis process, sample preparation and instrument analysis are key steps to improve analysis performance and accuracy. In recent years, chromatography combined with mass spectrometry (MS) has been widely used for the separation and detection of trace components in complex TCM samples. This article reviews various sample preparation techniques and chromatography-MS techniques, including the application of gas chromatography-MS and liquid chromatography-MS and other MS techniques in the characterization of phytochemicals in TCM materials and Chinese medicine products. This article also describes a new ambient ionization MS method for rapid and high-throughput analysis of TCM components.
Collapse
Affiliation(s)
- Chung-Yu Chen
- Research Center for Cancer Biology, China Medical University, Taichung, Taiwan, ROC
- Department of Chemistry, National Chung Hsing University, Taichung, Taiwan, ROC
| | - Yen-Hsien Li
- Department of Chemistry, National Chung Hsing University, Taichung, Taiwan, ROC
| | - Zuguang Li
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, People's Republic of China
| | - Maw-Rong Lee
- Department of Chemistry, National Chung Hsing University, Taichung, Taiwan, ROC
- Graduate Institute of Food Safety, National Chung Hsing University, Taichung, Taiwan, ROC
| |
Collapse
|
10
|
Cao Z, Yu LR. Mass Spectrometry-Based Proteomics for Biomarker Discovery. METHODS IN MOLECULAR BIOLOGY (CLIFTON, N.J.) 2022; 2486:3-17. [PMID: 35437715 DOI: 10.1007/978-1-0716-2265-0_1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Proteomics plays a pivotal role in systems medicine, in which pharmacoproteomics and toxicoproteomics have been developed to address questions related to efficacy and toxicity of drugs. Mass spectrometry is the core technology for quantitative proteomics, providing the capabilities of identification and quantitation of thousands of proteins. The technology has been applied to biomarker discovery and understanding the mechanisms of drug action. Both stable isotope labeling of proteins or peptides and label-free approaches have been incorporated with multidimensional LC separation and tandem mass spectrometry (LC-MS/MS) to increase the coverage and depth of proteome analysis. A protocol of such an approach exemplified by dimethyl labeling in combination with 2D-LC-MS/MS is described. With further development of novel proteomic tools and increase in sample throughput, the full spectrum of mass spectrometry-based proteomic research will greatly advance systems medicine.
Collapse
Affiliation(s)
- Zhijun Cao
- Division of Systems Biology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR, USA
| | - Li-Rong Yu
- Division of Systems Biology, National Center for Toxicological Research, U.S. Food and Drug Administration, Jefferson, AR, USA.
| |
Collapse
|
11
|
Abstract
Proteins are the molecular effectors of the information encoded in the genome. Proteomics aims at understanding the molecular functions of proteins in their biological context. In contrast to transcriptomics and genomics, the study of proteomes provides deeper insight into the dynamic regulatory layers encoded at the protein level, such as posttranslational modifications, subcellular localization, cell signaling, and protein-protein interactions. Currently, mass spectrometry (MS)-based proteomics is the technology of choice for studying proteomes at a system-wide scale, contributing to clinical biomarker discovery and fundamental molecular biology. MS technologies are continuously being developed to fulfill the requirements of speed, resolution, and quantitative accuracy, enabling the acquisition of comprehensive proteomes. In this review, we present how MS technology and acquisition methods have evolved to meet the requirements of cutting-edge proteomics research, which is describing the human proteome and its dynamic posttranslational modifications with unprecedented depth. Finally, we provide a perspective on studying proteomes at single-cell resolution. Expected final online publication date for the Annual Review of Genomics and Human Genetics, Volume 23 is October 2022. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.
Collapse
Affiliation(s)
- Ana Martinez-Val
- Novo Nordisk Foundation Center for Protein Research, Proteomics Program, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark;
| | - Ulises H Guzmán
- Novo Nordisk Foundation Center for Protein Research, Proteomics Program, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark;
| | - Jesper V Olsen
- Novo Nordisk Foundation Center for Protein Research, Proteomics Program, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark;
| |
Collapse
|
12
|
Zarrouk E, Lenski M, Bruno C, Thibert V, Contreras P, Privat K, Ameline A, Fabresse N. High-resolution mass spectrometry: Theoretical and technological aspects. TOXICOLOGIE ANALYTIQUE ET CLINIQUE 2022. [DOI: 10.1016/j.toxac.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
13
|
Abstract
Native mass spectrometry (MS) is aimed at preserving and determining the native structure, composition, and stoichiometry of biomolecules and their complexes from solution after they are transferred into the gas phase. Major improvements in native MS instrumentation and experimental methods over the past few decades have led to a concomitant increase in the complexity and heterogeneity of samples that can be analyzed, including protein-ligand complexes, protein complexes with multiple coexisting stoichiometries, and membrane protein-lipid assemblies. Heterogeneous features of these biomolecular samples can be important for understanding structure and function. However, sample heterogeneity can make assignment of ion mass, charge, composition, and structure very challenging due to the overlap of tens or even hundreds of peaks in the mass spectrum. In this review, we cover data analysis, experimental, and instrumental advances and strategies aimed at solving this problem, with an in-depth discussion of theoretical and practical aspects of the use of available deconvolution algorithms and tools. We also reflect upon current challenges and provide a view of the future of this exciting field.
Collapse
Affiliation(s)
- Amber D Rolland
- Department of Chemistry and Biochemistry, University of Oregon, Eugene, Oregon 97403-1253, United States
| | - James S Prell
- Department of Chemistry and Biochemistry, University of Oregon, Eugene, Oregon 97403-1253, United States.,Materials Science Institute, University of Oregon, Eugene, Oregon 97403-1252, United States
| |
Collapse
|
14
|
Bills JR, Nagornov KO, Kozhinov AN, Williams TJ, Tsybin YO, Marcus RK. Improved Uranium Isotope Ratio Analysis in Liquid Sampling-Atmospheric Pressure Glow Discharge/Orbitrap FTMS Coupling through the Use of an External Data Acquisition System. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1224-1236. [PMID: 33793219 DOI: 10.1021/jasms.1c00051] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Isotope ratio (IR) analysis of natural abundance uranium presents a formidable challenge for mass spectrometry (MS): the required spectral dynamic range needs to enable the quantitatively accurate measurement of the 234UO2 species present at ∼0.0053% isotopic abundance. We address this by empowering a benchtop Orbitrap Fourier transform mass spectrometer (FTMS) coupled with the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source and an external high-performance data acquisition system, FTMS Booster X2. The LS-APGD microplasma has demonstrated impressive capabilities regarding elemental and IR analysis when coupled with Orbitrap FTMS. Despite successes, there are limitations regarding the dynamic range and mass resolution that stem from space charge effects and data acquisition and processing restrictions. To overcome these limitations, the FTMS Booster was externally interfaced to an LS-APGD Q Exactive Focus Orbitrap FTMS to obtain time-domain signals (transients) and to process unreduced data. The unreduced time-domain data acquisition with user-controlled processing permit the evaluation of the effects of in-hardware transient phasing, increased transient lengths, advanced transient coadding, varying the length of a transient to be processed with a user-defined time increment, and the use of absorption-mode FT (aFT) processing methods on IR analysis. The added capabilities extend the spectral dynamic range of the instrument to at least 4-5 orders of magnitude and provide a resolution improvement from ∼70k to 900k m/Δm at 200 m/z. The empowered LS-APGD Orbitrap platform allows for the simultaneous measurement of 234UO2 and the prominent 235UO2 and 238UO2 isotopic species at their natural abundances, ultimately yielding improvements in performance when compared to previous uranium IR results on this same Q Exactive Focus instrument.
Collapse
Affiliation(s)
- Jacob R Bills
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | | | | | - Tyler J Williams
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| | | | - R Kenneth Marcus
- Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States
| |
Collapse
|
15
|
Palacio Lozano DC, Thomas MJ, Jones HE, Barrow MP. Petroleomics: Tools, Challenges, and Developments. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2020; 13:405-430. [PMID: 32197051 DOI: 10.1146/annurev-anchem-091619-091824] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The detailed molecular characterization of petroleum-related samples by mass spectrometry, often referred to as petroleomics, continues to present significant analytical challenges. As a result, petroleomics continues to be a driving force for the development of new ultrahigh resolution instrumentation, experimental methods, and data analysis procedures. Recent advances in ionization, resolving power, mass accuracy, and the use of separation methods, have allowed for record levels of compositional detail to be obtained for petroleum-related samples. To address the growing size and complexity of the data generated, vital software tools for data processing, analysis, and visualization continue to be developed. The insights gained impact upon the fields of energy and environmental science and the petrochemical industry, among others. In addition to advancing the understanding of one of nature's most complex mixtures, advances in petroleomics methodologies are being adapted for the study of other sample types, resulting in direct benefits to other fields.
Collapse
Affiliation(s)
| | - Mary J Thomas
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom;
- Molecular Analytical Sciences Centre for Doctoral Training, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Hugh E Jones
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom;
- Molecular Analytical Sciences Centre for Doctoral Training, University of Warwick, Coventry CV4 7AL, United Kingdom
| | - Mark P Barrow
- Department of Chemistry, University of Warwick, Coventry CV4 7AL, United Kingdom;
| |
Collapse
|
16
|
Morris CB, Poland JC, May JC, McLean JA. Fundamentals of Ion Mobility-Mass Spectrometry for the Analysis of Biomolecules. Methods Mol Biol 2020; 2084:1-31. [PMID: 31729651 DOI: 10.1007/978-1-0716-0030-6_1] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Ion mobility-mass spectrometry (IM-MS) combines complementary size- and mass-selective separations into a single analytical platform. This chapter provides context for both the instrumental arrangements and key application areas that are commonly encountered in bioanalytical settings. New advances in these high-throughput strategies are described with description of complementary informatics tools to effectively utilize these data-intensive measurements. Rapid separations such as these are especially important in systems, synthetic, and chemical biology in which many small molecules are transient and correspond to various biological classes for integrated omics measurements. This chapter highlights the fundamentals of IM-MS and its applications toward biomolecular separations and discusses methods currently being used in the fields of proteomics, lipidomics, and metabolomics.
Collapse
Affiliation(s)
- Caleb B Morris
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA.,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA
| | - James C Poland
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA.,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA
| | - Jody C May
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA.,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Vanderbilt University, Nashville, TN, USA. .,Vanderbilt-Ingram Cancer Center, Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, TN, USA.
| |
Collapse
|
17
|
Affiliation(s)
- Patricia Forbes
- Department of Chemistry, University of Pretoria, Lynnwood Road, Pretoria 0002, South Africa
| |
Collapse
|
18
|
|
19
|
Toby TK, Fornelli L, Srzentić K, DeHart CJ, Levitsky J, Friedewald J, Kelleher NL. A comprehensive pipeline for translational top-down proteomics from a single blood draw. Nat Protoc 2019; 14:119-152. [PMID: 30518910 DOI: 10.1038/s41596-018-0085-7] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Top-down proteomics (TDP) by mass spectrometry (MS) is a technique by which intact proteins are analyzed. It has become increasingly popDesalting and concentrating GELFrEEular in translational research because of the value of characterizing distinct proteoforms of intact proteins. Compared to bottom-up proteomics (BUP) strategies, which measure digested peptide mixtures, TDP provides highly specific molecular information that avoids the bioinformatic challenge of protein inference. However, the technique has been difficult to implement widely because of inherent limitations of existing sample preparation methods and instrumentation. Recent improvements in proteoform pre-fractionation and the availability of high-resolution benchtop mass spectrometers have made it possible to use high-throughput TDP for the analysis of complex clinical samples. Here, we provide a comprehensive protocol for analysis of a common sample type in translational research: human peripheral blood mononuclear cells (PBMCs). The pipeline comprises multiple workflows that can be treated as modular by the reader and used for various applications. First, sample collection and cell preservation are described for two clinical biorepository storage schemes. Cell lysis and proteoform pre-fractionation by gel-eluted liquid fractionation entrapment electrophoresis are then described. Importantly, instrument setup and liquid chromatography-tandem MS are described for TDP analyses, which rely on high-resolution Fourier-transform MS. Finally, data processing and analysis are described using two different, application-dependent software tools: ProSight Lite for targeted analyses of one or a few proteoforms and TDPortal for high-throughput TDP in discovery mode. For a single sample, the minimum completion time of the entire experiment is 72 h.
Collapse
Affiliation(s)
- Timothy K Toby
- Departments of Chemistry and of Molecular Biosciences, Northwestern University, Evanston, IL, USA
| | - Luca Fornelli
- Departments of Chemistry and of Molecular Biosciences, Northwestern University, Evanston, IL, USA
| | - Kristina Srzentić
- Departments of Chemistry and of Molecular Biosciences, Northwestern University, Evanston, IL, USA
| | - Caroline J DeHart
- National Resource for Translational and Developmental Proteomics, Northwestern University, Evanston, IL, USA
| | - Josh Levitsky
- Comprehensive Transplant Center, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - John Friedewald
- Comprehensive Transplant Center, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Neil L Kelleher
- Departments of Chemistry and of Molecular Biosciences, Northwestern University, Evanston, IL, USA. .,National Resource for Translational and Developmental Proteomics, Northwestern University, Evanston, IL, USA.
| |
Collapse
|
20
|
Zhang Y, Wen Z, Washburn MP, Florens L. Evaluating Chromatographic Approaches for the Quantitative Analysis of a Human Proteome on Orbitrap-Based Mass Spectrometry Systems. J Proteome Res 2019; 18:1857-1869. [PMID: 30884231 DOI: 10.1021/acs.jproteome.9b00036] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The Orbitrap is now a core component of several different instruments. However, evaluating the capabilities of each system is lacking in the field. Here, we compared the performance of multidimensional protein identification (MudPIT) on Velos Pro Orbitrap and Velos Orbitrap Elite mass spectrometers to reversed phase liquid chromatography (RPLC) on a Q-Exactive Plus and an Orbitrap Fusion Lumos. Using HeLa cell protein digests, we carried out triplicate analyses of 16 different chromatography conditions on four different instrumentation platforms. We first optimized RPLC conditions by varying column lengths, inner diameters, and particle sizes. We found that smaller particle sizes improve results but only with smaller inner diameter microcapillary columns. We then selected one chromatography condition on each system and varied gradient lengths. We used distributed normalized spectral abundance factor (dNSAF) values to determine quantitative reproducibility. With Pearson product-moment correlation coefficient r values routinely above 0.96, single RPLC on both the QE+ and Orbitrap Lumos outperformed MudPIT on the Orbitrap Elite mass spectrometer. In addition, when comparing dNSAF values measured for the same proteins across the different platforms, RPLC on the Orbitrap Lumos had greater sensitivity than MudPIT, as demonstrated by the detection and quantification of histone deacetylase complex components. Data are available via ProteomeXchange with identifier 10.6019/PXD009875.
Collapse
Affiliation(s)
- Ying Zhang
- Stowers Institute for Medical Research , Kansas City , Missouri 64110 , United States
| | - Zhihui Wen
- Stowers Institute for Medical Research , Kansas City , Missouri 64110 , United States
| | - Michael P Washburn
- Stowers Institute for Medical Research , Kansas City , Missouri 64110 , United States.,Department of Pathology and Laboratory Medicine , University of Kansas Medical Center , Kansas City , Kansas 66160 , United States
| | - Laurence Florens
- Stowers Institute for Medical Research , Kansas City , Missouri 64110 , United States
| |
Collapse
|
21
|
Nolting D, Malek R, Makarov A. Ion traps in modern mass spectrometry. MASS SPECTROMETRY REVIEWS 2019; 38:150-168. [PMID: 29084367 DOI: 10.1002/mas.21549] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Accepted: 09/19/2017] [Indexed: 06/07/2023]
Abstract
This review is devoted to trapping mass spectrometry wherein ions are confined by electromagnetic fields for prolonged periods of time within limited volume, with mass measurement taking place within the same volume. Three major types of trapping mass spectrometers are discussed, specifically radiofrequency ion trap, Fourier transform ion cyclotron resonance and Orbitrap. While these three branches are intricately interwoven with each other over their recent history, they also differ greatly in their fundamentals, roots and historical origin. This diversity is reflected also in the difference of viewpoints from which each of these directions is addressed in this review. Following the theme of the issue, we focus on developments mainly associated with the country of Germany but, at the same time, we use this review as an illustration of the rapidly increasing globalization of science and expanding multi-national collaborations.
Collapse
|
22
|
Abstract
The mechanism underlying many biological phenotypes remains unknown despite the increasing availability of whole genome and transcriptome sequencing. Direct measurement of changes in protein expression is an attractive alternative and has the potential to reveal novel processes. Mass spectrometry has become the standard method for proteomics, allowing both the confident identification and quantification of thousands of proteins from biological samples. In this review, mass spectrometry-based proteomic methods and their applications are described.
Collapse
Affiliation(s)
- J Robert O'Neill
- Cancer Research UK Edinburgh Centre, MRC Institute of Genetics and Molecular Medicine, The University of Edinburgh, Edinburgh, UK. Robert.o'.,Department of Clinical Surgery, Royal Infirmary of Edinburgh, Edinburgh, UK. Robert.o'
| |
Collapse
|
23
|
Ma Q, Adua E, Boyce MC, Li X, Ji G, Wang W. IMass Time: The Future, in Future! ACTA ACUST UNITED AC 2018; 22:679-695. [DOI: 10.1089/omi.2018.0162] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Qingwei Ma
- Bioyong (Beijing) Technology Co., Ltd., Beijing, China
| | - Eric Adua
- School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia
| | - Mary C. Boyce
- School of Science, Edith Cowan University, Joondalup, Australia
| | - Xingang Li
- School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia
| | - Guang Ji
- China-Canada Centre of Research for Digestive Diseases, University of Ottawa, Ottawa, Canada
- Institute of Digestive Diseases, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Wei Wang
- School of Medical and Health Sciences, Edith Cowan University, Joondalup, Australia
- School of Public Health, Taishan Medical University, Taian, China
| |
Collapse
|
24
|
Filatov VV, Kozlovskiy VI. Note: Isolated high-voltage thermo-compensated DC power supply for mass spectrometry. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:116105. [PMID: 30501341 DOI: 10.1063/1.5061830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2018] [Accepted: 10/30/2018] [Indexed: 06/09/2023]
Abstract
The design of a highly stable isolated high voltage power supply is proposed and developed. The power supply is characterized by good temperature stability (<15 ppm/°C) and very low ripple level (<7 ppm) which were reduced by using a sinusoidal voltage in the transformer conversion. We anticipate that the power supplies of this type can find their utility in modern high-resolution mass spectrometers, particularly in time-of-flight and Orbitrap-type instruments providing a high resolution of ∼100 000 FWHM and high accuracy of m/z determination.
Collapse
Affiliation(s)
- V V Filatov
- Talrose Institute for Energy Problems of Chemical Physics Russian Academy of Science, Chernogolovka 142432, Russia
| | - V I Kozlovskiy
- Talrose Institute for Energy Problems of Chemical Physics Russian Academy of Science, Chernogolovka 142432, Russia
| |
Collapse
|
25
|
Bowers JJ, Gunawardena HP, Cornu A, Narvekar AS, Richieu A, Deffieux D, Quideau S, Tharayil N. Rapid Screening of Ellagitannins in Natural Sources via Targeted Reporter Ion Triggered Tandem Mass Spectrometry. Sci Rep 2018; 8:10399. [PMID: 29991731 PMCID: PMC6039434 DOI: 10.1038/s41598-018-27708-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 05/17/2018] [Indexed: 12/18/2022] Open
Abstract
Complex biomolecules present in their natural sources have been difficult to analyze using traditional analytical approaches. Ultrahigh-performance liquid chromatography (UHPLC-MS/MS) methods have the potential to enhance the discovery of a less well characterized and challenging class of biomolecules in plants, the ellagitannins. We present an approach that allows for the screening of ellagitannins by employing higher energy collision dissociation (HCD) to generate reporter ions for classification and collision-induced dissociation (CID) to generate unique fragmentation spectra for isomeric variants of previously unreported species. Ellagitannin anions efficiently form three characteristic reporter ions after HCD fragmentation that allows for the classification of unknown precursors that we call targeted reporter ion triggering (TRT). We demonstrate how a tandem HCD-CID experiment might be used to screen natural sources using UHPLC-MS/MS by application of 22 method conditions from which an optimized data-dependent acquisition (DDA) emerged. The method was verified not to yield false-positive results in complex plant matrices. We were able to identify 154 non-isomeric ellagitannins from strawberry leaves, which is 17 times higher than previously reported in the same matrix. The systematic inclusion of CID spectra for isomers of each species classified as an ellagitannin has never been possible before the development of this approach.
Collapse
Affiliation(s)
- Jeremiah J Bowers
- Department of Plant and Environmental Sciences, Clemson University, Clemson, SC, 29631, USA
| | - Harsha P Gunawardena
- Janssen Research and Development, The Janssen Pharmaceutical Companies of Johnson and Johnson, Spring House, PA, 19477, USA
| | - Anaëlle Cornu
- University Bordeaux, ISM (CNRS-UMR 5255), 351 cours de la Libération, 33405, Talence Cedex, France
| | - Ashwini S Narvekar
- Department of Plant and Environmental Sciences, Clemson University, Clemson, SC, 29631, USA
| | - Antoine Richieu
- University Bordeaux, ISM (CNRS-UMR 5255), 351 cours de la Libération, 33405, Talence Cedex, France
| | - Denis Deffieux
- University Bordeaux, ISM (CNRS-UMR 5255), 351 cours de la Libération, 33405, Talence Cedex, France
| | - Stéphane Quideau
- University Bordeaux, ISM (CNRS-UMR 5255), 351 cours de la Libération, 33405, Talence Cedex, France
| | - Nishanth Tharayil
- Department of Plant and Environmental Sciences, Clemson University, Clemson, SC, 29631, USA.
| |
Collapse
|
26
|
Hernández F, Castiglioni S, Covaci A, de Voogt P, Emke E, Kasprzyk‐Hordern B, Ort C, Reid M, Sancho JV, Thomas KV, van Nuijs AL, Zuccato E, Bijlsma L. Mass spectrometric strategies for the investigation of biomarkers of illicit drug use in wastewater. MASS SPECTROMETRY REVIEWS 2018; 37:258-280. [PMID: 27750373 PMCID: PMC6191649 DOI: 10.1002/mas.21525] [Citation(s) in RCA: 66] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2016] [Accepted: 09/30/2016] [Indexed: 05/04/2023]
Abstract
The analysis of illicit drugs in urban wastewater is the basis of wastewater-based epidemiology (WBE), and has received much scientific attention because the concentrations measured can be used as a new non-intrusive tool to provide evidence-based and real-time estimates of community-wide drug consumption. Moreover, WBE allows monitoring patterns and spatial and temporal trends of drug use. Although information and expertise from other disciplines is required to refine and effectively apply WBE, analytical chemistry is the fundamental driver in this field. The use of advanced analytical techniques, commonly based on combined chromatography-mass spectrometry, is mandatory because the very low analyte concentration and the complexity of samples (raw wastewater) make quantification and identification/confirmation of illicit drug biomarkers (IDBs) troublesome. We review the most-recent literature available (mostly from the last 5 years) on the determination of IDBs in wastewater with particular emphasis on the different analytical strategies applied. The predominance of liquid chromatography coupled to tandem mass spectrometry to quantify target IDBs and the essence to produce reliable and comparable results is illustrated. Accordingly, the importance to perform inter-laboratory exercises and the need to analyze appropriate quality controls in each sample sequence is highlighted. Other crucial steps in WBE, such as sample collection and sample pre-treatment, are briefly and carefully discussed. The article further focuses on the potential of high-resolution mass spectrometry. Different approaches for target and non-target analysis are discussed, and the interest to perform experiments under laboratory-controlled conditions, as a complementary tool to investigate related compounds (e.g., minor metabolites and/or transformation products in wastewater) is treated. The article ends up with the trends and future perspectives in this field from the authors' point of view. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 37:258-280, 2018.
Collapse
Affiliation(s)
- Félix Hernández
- Research Institute for Pesticides and WaterUniversity Jaume ICastellónSpain
| | - Sara Castiglioni
- Department of Environmental Health SciencesIRCCS—Istituto di Ricerche Farmacologiche Mario NegriMilanItaly
| | - Adrian Covaci
- Toxicological CenterUniversity of AntwerpAntwerpBelgium
| | - Pim de Voogt
- KWR Watercycle Research InstituteNieuwegeinthe Netherlands
- IBED—University of AmsterdamAmsterdamthe Netherlands
| | - Erik Emke
- KWR Watercycle Research InstituteNieuwegeinthe Netherlands
| | | | - Christoph Ort
- Swiss Federal Institute of Aquatic Science and Technology (Eawag)DübendorfSwitzerland
| | - Malcolm Reid
- Norwegian Institute for Water Research (NIVA)OsloNorway
| | - Juan V. Sancho
- Research Institute for Pesticides and WaterUniversity Jaume ICastellónSpain
| | | | | | - Ettore Zuccato
- Department of Environmental Health SciencesIRCCS—Istituto di Ricerche Farmacologiche Mario NegriMilanItaly
| | - Lubertus Bijlsma
- Research Institute for Pesticides and WaterUniversity Jaume ICastellónSpain
| |
Collapse
|
27
|
Jang KS, Kim YH. Rapid and robust MALDI-TOF MS techniques for microbial identification: a brief overview of their diverse applications. J Microbiol 2018; 56:209-216. [PMID: 29492868 DOI: 10.1007/s12275-018-7457-0] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Revised: 01/23/2018] [Accepted: 01/24/2018] [Indexed: 10/25/2022]
Abstract
in mass spectrometry have enabled the investigation of various biological systems by directly analyzing diverse sets of biomolecules (i.e., proteins, lipids, and carbohydrates), thus making a significant impact on the life sciences field. Over the past decade, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been widely utilized as a rapid and reliable method for the identification of microorganisms. MALDI-TOF MS has come into widespread use despite its relatively low resolving power (full width at half maximum, FWHM: < 5,000) and its incompatibility with tandem MS analysis, features with which other high-resolution mass spectrometers are equipped. Microbial identification is achieved by searching databases containing mass spectra of peptides and proteins extracted from microorganisms of interest, using scoring algorithms to match analyzed spectra with reference spectra. In this paper, we give a brief overview of the diverse applications of rapid and robust MALDI-TOF MS-based techniques for microbial identification in a variety of fields, such as clinical diagnosis and environmental and food monitoring. We also describe the fundamental principles of MALDI-TOF MS. The general specifications of the two major MS-based microbial identification systems available in the global market (BioTyper® and VITEK® MS Plus) and the distribution of these instruments in Republic of Korea are also discussed. The current review provides an understanding of this emerging microbial identification and classification technology and will help bacteriologists and cell biologists take advantage of this powerful technique.
Collapse
Affiliation(s)
- Kyoung-Soon Jang
- Biomedical Omics Group, Korea Basic Science Institute, Cheongju, 28119, Republic of Korea. .,Department of Bio-Analytical Science, University of Science and Technology, Daejeon, 34113, Republic of Korea.
| | - Young Hwan Kim
- Biomedical Omics Group, Korea Basic Science Institute, Cheongju, 28119, Republic of Korea.,Department of Bio-Analytical Science, University of Science and Technology, Daejeon, 34113, Republic of Korea.,Graduate School of Analytical Science and Technology, Chungnam National University, Daejeon, 34134, Republic of Korea
| |
Collapse
|
28
|
Brahim B, Tabet JC, Alves S. Positive and negative ion mode comparison for the determination of DNA/peptide noncovalent binding sites through the formation of "three-body" noncovalent fragment ions. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2018; 24:168-177. [PMID: 29232990 DOI: 10.1177/1469066717735672] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Gas-phase fragmentation of single strand DNA-peptide noncovalent complexes is investigated in positive and negative electrospray ionization modes.Collision-induced dissociation experiments, performed on the positively charged noncovalent complex precursor ions, have confirmed the trend previously observed in negative ion mode, i.e. a high stability of noncovalent complexes containing very basic peptidic residues (i.e. R > K) and acidic nucleotide units (i.e. Thy units), certainly incoming from the existence of salt bridge interactions. Independent of the ion polarity, stable noncovalent complex precursor ions were found to dissociate preferentially through covalent bond cleavages of the partners without disrupting noncovalent interactions. The resulting DNA fragment ions were found to be still noncovalently linked to the peptides. Additionally, the losses of an internal nucleic fragment producing "three-body" noncovalent fragment ions were also observed in both ion polarities, demonstrating the spectacular salt bridge interaction stability. The identical fragmentation patterns (regardless of the relative fragment ion abundances) observed in both polarities have shown a common location of salt bridge interaction certainly preserved from solution. Nonetheless, most abundant noncovalent fragment ions (and particularly three-body ones) are observed from positively charged noncovalent complexes. Therefore, we assume that, independent of the preexisting salt bridge interaction and zwitterion structures, multiple covalent bond cleavages from single-stranded DNA/peptide complexes rely on an excess of positive charges in both electrospray ionization ion polarities.
Collapse
Affiliation(s)
- Bessem Brahim
- Sorbonne Universités - UPMC Paris 06, Institut Parisien de Chimie Moléculaire (IPCM) University, Paris, France
| | - Jean-Claude Tabet
- Sorbonne Universités - UPMC Paris 06, Institut Parisien de Chimie Moléculaire (IPCM) University, Paris, France
| | - Sandra Alves
- Sorbonne Universités - UPMC Paris 06, Institut Parisien de Chimie Moléculaire (IPCM) University, Paris, France
| |
Collapse
|
29
|
Khodjaniyazova S, Nazari M, Garrard KP, Matos MPV, Jackson GP, Muddiman DC. Characterization of the Spectral Accuracy of an Orbitrap Mass Analyzer Using Isotope Ratio Mass Spectrometry. Anal Chem 2018; 90:1897-1906. [DOI: 10.1021/acs.analchem.7b03983] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Sitora Khodjaniyazova
- Department
of Chemistry and Molecular Education, Technology, and Research Innovation
Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Milad Nazari
- Department
of Chemistry and Molecular Education, Technology, and Research Innovation
Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| | - Kenneth P. Garrard
- Department
of Chemistry and Molecular Education, Technology, and Research Innovation
Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
- Precision
Engineering Consortium, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina 27606, United States
| | | | | | - David C. Muddiman
- Department
of Chemistry and Molecular Education, Technology, and Research Innovation
Center (METRIC), North Carolina State University, Raleigh, North Carolina 27695, United States
| |
Collapse
|
30
|
Some Applications of Liquid Chromatography-Mass Spectrometry in the Biomedical Field. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/bs.coac.2017.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
31
|
Iwamoto N, Shimada T. Recent advances in mass spectrometry-based approaches for proteomics and biologics: Great contribution for developing therapeutic antibodies. Pharmacol Ther 2017; 185:147-154. [PMID: 29274706 DOI: 10.1016/j.pharmthera.2017.12.007] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Since the turn of the century, mass spectrometry (MS) technologies have continued to improve dramatically, and advanced strategies that were impossible a decade ago are increasingly becoming available. The basic characteristics behind these advancements are MS resolution, quantitative accuracy, and information science for appropriate data processing. The spectral data from MS contain various types of information. The benefits of improving the resolution of MS data include accurate molecular structural-derived information, and as a result, we can obtain a refined biomolecular structure determination in a sequential and large-scale manner. Moreover, in MS data, not only accurate structural information but also the generated ion amount plays an important rule. This progress has greatly contributed a research field that captures biological events as a system by comprehensively tracing the various changes in biomolecular dynamics. The sequential changes of proteome expression in biological pathways are very essential, and the amounts of the changes often directly become the targets of drug discovery or indicators of clinical efficacy. To take this proteomic approach, it is necessary to separate the individual MS spectra derived from each biomolecule in the complexed biological samples. MS itself is not so infinite to perform the all peak separation, and we should consider improving the methods for sample processing and purification to make them suitable for injection into MS. The above-described characteristics can only be achieved using MS with any analytical instrument. Moreover, MS is expected to be applied and expand into many fields, not only basic life sciences but also forensic medicine, plant sciences, materials, and natural products. In this review, we focus on the technical fundamentals and future aspects of the strategies for accurate structural identification, structure-indicated quantitation, and on the challenges for pharmacokinetics of high-molecular-weight protein biopharmaceuticals.
Collapse
Affiliation(s)
- Noriko Iwamoto
- Leading Technology of Bioanalysis and Protein Chemistry, SHIMADZU Corporation, Kyoto, Japan
| | - Takashi Shimada
- Leading Technology of Bioanalysis and Protein Chemistry, SHIMADZU Corporation, Kyoto, Japan.
| |
Collapse
|
32
|
See KA, Liu YM, Ha Y, Barile CJ, Gewirth AA. Effect of Concentration on the Electrochemistry and Speciation of the Magnesium Aluminum Chloride Complex Electrolyte Solution. ACS APPLIED MATERIALS & INTERFACES 2017; 9:35729-35739. [PMID: 28933814 DOI: 10.1021/acsami.7b08088] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Magnesium batteries offer an opportunity to use naturally abundant Mg and achieve large volumetric capacities reaching over four times that of conventional Li-based intercalation anodes. High volumetric capacity is enabled by the use of a Mg metal anode in which charge is stored via electrodeposition and stripping processes, however, electrolytes that support efficient Mg electrodeposition and stripping are few and are often prepared from highly reactive compounds. One interesting electrolyte solution that supports Mg deposition and stripping without the use of highly reactive reagents is the magnesium aluminum chloride complex (MACC) electrolyte. The MACC exhibits high Coulombic efficiencies and low deposition overpotentials following an electrolytic conditioning protocol that stabilizes species necessary for such behavior. Here, we discuss the effect of the MgCl2 and AlCl3 concentrations on the deposition overpotential, current density, and the conditioning process. Higher concentrations of MACC exhibit enhanced Mg electrodeposition current density and much faster conditioning. An increase in the salt concentrations causes a shift in the complex equilibria involving both cations. The conditioning process is strongly dependent on the concentration suggesting that the electrolyte is activated through a change in speciation of electrolyte complexes and is not simply due to the annihilation of electrolyte impurities. Additionally, the presence of the [Mg2(μ-Cl)3·6THF]+ in the electrolyte solution is again confirmed through careful analysis of experimental Raman spectra coupled with simulation and direct observation of the complex in sonic spray ionization mass spectrometry. Importantly, we suggest that the ∼210 cm-1 mode commonly observed in the Raman spectra of many Mg electrolytes is indicative of the C3v symmetric [Mg2(μ-Cl)3·6THF]+. The 210 cm-1 mode is present in many electrolytes containing MgCl2, so its assignment is of broad interest to the Mg electrolyte community.
Collapse
Affiliation(s)
- Kimberly A See
- Department of Chemistry, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801, United States
| | - Yao-Min Liu
- Department of Chemistry, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801, United States
| | - Yeyoung Ha
- Department of Chemistry, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801, United States
| | - Christopher J Barile
- Department of Chemistry, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801, United States
| | - Andrew A Gewirth
- Department of Chemistry, University of Illinois at Urbana-Champaign , Urbana, Illinois 61801, United States
| |
Collapse
|
33
|
Andjelković U, Šrajer Gajdošik M, Gašo-Sokač D, Martinović T, Josić D. Foodomics and Food Safety: Where We Are. Food Technol Biotechnol 2017; 55:290-307. [PMID: 29089845 PMCID: PMC5654429 DOI: 10.17113/ftb.55.03.17.5044] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Accepted: 05/31/2017] [Indexed: 12/21/2022] Open
Abstract
The power of foodomics as a discipline that is now broadly used for quality assurance of food products and adulteration identification, as well as for determining the safety of food, is presented. Concerning sample preparation and application, maintenance of highly sophisticated instruments for both high-performance and high-throughput techniques, and analysis and data interpretation, special attention has to be paid to the development of skilled analysts. The obtained data shall be integrated under a strong bioinformatics environment. Modern mass spectrometry is an extremely powerful analytical tool since it can provide direct qualitative and quantitative information about a molecule of interest from only a minute amount of sample. Quality of this information is influenced by the sample preparation procedure, the type of mass spectrometer used and the analyst's skills. Technical advances are bringing new instruments of increased sensitivity, resolution and speed to the market. Other methods presented here give additional information and can be used as complementary tools to mass spectrometry or for validation of obtained results. Genomics and transcriptomics, as well as affinity-based methods, still have a broad use in food analysis. Serious drawbacks of some of them, especially the affinity-based methods, are the cross-reactivity between similar molecules and the influence of complex food matrices. However, these techniques can be used for pre-screening in order to reduce the large number of samples. Great progress has been made in the application of bioinformatics in foodomics. These developments enabled processing of large amounts of generated data for both identification and quantification, and for corresponding modeling.
Collapse
Affiliation(s)
- Uroš Andjelković
- Department of Biotechnology, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka, Croatia
- Department of Chemistry, Institute of Chemistry, Technology and Metallurgy, University of Belgrade, Njegoševa 12, RS-11000 Belgrade, Serbia
| | - Martina Šrajer Gajdošik
- Department of Chemistry, J. J. Strossmayer University of Osijek, Cara Hadrijana 8/A, HR-31000 Osijek, Croatia
| | - Dajana Gašo-Sokač
- Faculty of Food Technology, J. J. Strossmayer University of Osijek, Franje Kuhača 20, HR-31000 Osijek, Croatia
| | - Tamara Martinović
- Department of Biotechnology, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka, Croatia
| | - Djuro Josić
- Department of Biotechnology, University of Rijeka, Radmile Matejčić 2, HR-51000 Rijeka, Croatia
- Warren Alpert Medical School, Brown University, 222 Richmond St, Providence, RI 02903, USA
| |
Collapse
|
34
|
Cifani P, Kentsis A. High Sensitivity Quantitative Proteomics Using Automated Multidimensional Nano-flow Chromatography and Accumulated Ion Monitoring on Quadrupole-Orbitrap-Linear Ion Trap Mass Spectrometer. Mol Cell Proteomics 2017; 16:2006-2016. [PMID: 28821601 DOI: 10.1074/mcp.ra117.000023] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Indexed: 01/18/2023] Open
Abstract
Quantitative proteomics using high-resolution and accuracy mass spectrometry promises to transform our understanding of biological systems and disease. Recent development of parallel reaction monitoring (PRM) using hybrid instruments substantially improved the specificity of targeted mass spectrometry. Combined with high-efficiency ion trapping, this approach also provided significant improvements in sensitivity. Here, we investigated the effects of ion isolation and accumulation on the sensitivity and quantitative accuracy of targeted proteomics using the recently developed hybrid quadrupole-Orbitrap-linear ion trap mass spectrometer. We leveraged ultrahigh efficiency nano-electrospray ionization under optimized conditions to achieve yoctomolar sensitivity with more than seven orders of linear quantitative accuracy. To enable sensitive and specific targeted mass spectrometry, we implemented an automated, two-dimensional (2D) ion exchange-reversed phase nanoscale chromatography system. We found that automated 2D chromatography improved the sensitivity and accuracy of both PRM and an intact precursor scanning mass spectrometry method, termed accumulated ion monitoring (AIM), by more than 100-fold. Combined with automated 2D nano-scale chromatography, AIM achieved subattomolar limits of detection of endogenous proteins in complex biological proteomes. This allowed quantitation of absolute abundance of the human transcription factor MEF2C at ∼100 molecules/cell, and determination of its phosphorylation stoichiometry from as little as 1 μg of extracts isolated from 10,000 human cells. The combination of automated multidimensional nano-scale chromatography and targeted mass spectrometry should enable ultrasensitive high-accuracy quantitative proteomics of complex biological systems and diseases.
Collapse
Affiliation(s)
- Paolo Cifani
- From the ‡Molecular Pharmacology Program, Sloan Kettering Institute, Memorial Sloan Kettering Cancer Center, New York, NY 10065
| | - Alex Kentsis
- From the ‡Molecular Pharmacology Program, Sloan Kettering Institute, Memorial Sloan Kettering Cancer Center, New York, NY 10065; .,§Department of Pediatrics, Weill Medical College of Cornell University and Memorial Sloan Kettering Cancer Center, New York, NY 10065
| |
Collapse
|
35
|
Saleh Al-w A, Nazri Isma M, Muhamad Sa S, Abdul Khal I, Ayesh Moha S, Alsayrafi M, Michael Ha T, Binti A. L A. Identification of Glycobiomarker Candidates for Breast Cancer Using LTQ-Orbitrap Fusion Technique. INT J PHARMACOL 2017. [DOI: 10.3923/ijp.2017.425.437] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
36
|
Mathews TP, Carter MD, Johnson D, Isenberg SL, Graham LA, Thomas JD, Johnson RC. High-Confidence Qualitative Identification of Organophosphorus Nerve Agent Adducts to Human Butyrylcholinesterase. Anal Chem 2017; 89:1955-1964. [PMID: 28208252 DOI: 10.1021/acs.analchem.6b04441] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
In this study, a data-dependent, high-resolution tandem mass spectrometry (ddHRMS/MS) method capable of detecting all organophosphorus nerve agent (OPNA) adducts to human butyrylcholinesterase (BChE) was developed. After an exposure event, immunoprecipitation from blood with a BChE-specific antibody and digestion with pepsin produces a nine amino acid peptide containing the OPNA adduct. Signature product ions of this peptic BChE nonapeptide (FGES*AGAAS) offer a route to broadly screen for OPNA exposure. Taking this approach on an HRMS instrument identifies biomarkers, including unknowns, with high mass accuracy. Using a set of pooled human sera exposed to OPNAs as quality control (QC) materials, the developed method successfully identified precursor ions with <1 ppm and tied them to signature product ions with <5 ppm deviation from their chemical formulas. This high mass accuracy data from precursor and product ions, collected over 23 independent immunoprecipitation preparations, established method operating limits. QC data and experiments with 14 synthetic reference peptides indicated that reliable qualitative identification of biomarkers was possible for analytes >15 ng/mL. The developed method was applied to a convenience set of 96 unexposed serum samples and a blinded set of 80 samples treated with OPNAs. OPNA biomarkers were not observed in convenience set samples and no false positive or negative identifications were observed in blinded samples. All biomarkers in the blinded serum set >15 ng/mL were correctly identified. For the first time, this study reports a ddHRMS/MS method capable of complementing existing quantitative methodologies and suitable for identifying exposure to unknown organophosphorus agents.
Collapse
Affiliation(s)
- Thomas P Mathews
- Battelle at the Centers for Disease Control and Prevention , Atlanta, Georgia 30341, United States
| | - Melissa D Carter
- Centers for Disease Control and Prevention , National Center for Environmental Health, Division of Laboratory Sciences, Atlanta, Georgia 30341, United States
| | - Darryl Johnson
- Oak Ridge Institute for Science and Education Fellow at the Centers for Disease Control and Prevention , Atlanta, Georgia 30341, United States
| | - Samantha L Isenberg
- Centers for Disease Control and Prevention , National Center for Environmental Health, Division of Laboratory Sciences, Atlanta, Georgia 30341, United States
| | - Leigh Ann Graham
- Battelle at the Centers for Disease Control and Prevention , Atlanta, Georgia 30341, United States
| | - Jerry D Thomas
- Centers for Disease Control and Prevention , National Center for Environmental Health, Division of Laboratory Sciences, Atlanta, Georgia 30341, United States
| | - Rudolph C Johnson
- Centers for Disease Control and Prevention , National Center for Environmental Health, Division of Laboratory Sciences, Atlanta, Georgia 30341, United States
| |
Collapse
|
37
|
|
38
|
|
39
|
Lehmann WD. A timeline of stable isotopes and mass spectrometry in the life sciences. MASS SPECTROMETRY REVIEWS 2017; 36:58-85. [PMID: 26919394 DOI: 10.1002/mas.21497] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 01/21/2016] [Indexed: 06/05/2023]
Abstract
This review retraces the role of stable isotopes and mass spectrometry in the life sciences. The timeline is divided into four segments covering the years 1920-1950, 1950-1980, 1980-2000, and 2000 until today. For each period methodic progress and typical applications are discussed. Application of stable isotopes is driven by improvements of mass spectrometry, chromatography, and related fields in sensitivity, mass accuracy, structural specificity, complex sample handling ability, data output, and data evaluation. We currently experience the vision of omics-type analyses, that is, the comprehensive identification and quantification of a complete compound class within one or a few analytical runs. This development is driven by stable isotopes without competition by radioisotopes. In metabolic studies as classic field of isotopic tracer experiments, stable isotopes and radioisotopes were competing solutions, with stable isotopes as the long-term junior partner. Since the 1990s the number of metabolic studies with radioisotopes decreases, whereas stable isotope studies retain their slow but stable upward tendency. Unique fields of stable isotopes are metabolic tests in newborns, metabolic experiments in healthy controls, newborn screening for inborn errors, quantification of drugs and drug metabolites in doping control, natural isotope fractionation in geology, ecology, food authentication, or doping control, and more recently the field of quantitative omics-type analyses. There, cells or whole organisms are systematically labeled with stable isotopes to study proteomic differences or specific responses to stimuli or genetic manipulation. The duo of stable isotopes and mass spectrometry will probably continue to grow in the life sciences, since it delivers reference-quality quantitative data with molecular specificity, often combined with informative isotope effects. © 2016 Wiley Periodicals, Inc. Mass Spec Rev 36:58-85, 2017.
Collapse
Affiliation(s)
- Wolf D Lehmann
- German Cancer Research Center (DKFZ), D-69120 Heidelberg, Germany
| |
Collapse
|
40
|
Ang CS, Baker MS, Nice EC. Mass Spectrometry-Based Analysis for the Discovery and Validation of Potential Colorectal Cancer Stool Biomarkers. Methods Enzymol 2016; 586:247-274. [PMID: 28137566 DOI: 10.1016/bs.mie.2016.10.019] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Colorectal cancer (CRC) is the third leading cause of cancer mortality for both men and women, and the second leading cause of cancer death for men and women combined. If detected early, before metastasis has occurred, survival following surgical resection of the tumor is >90%. Early detection is therefore critical for effective disease surveillance. Unfortunately, current biomarker assays lack the necessary sensitivity and specificity for reliable early disease detection. Development of new robust, non- or minimally invasive specific and sensitive biomarkers or panels with improved compliance and performance is therefore urgently required. The use of fecal samples offers several advantages over other clinical biospecimens (e.g., plasma or serum) as a source of CRC biomarkers, including: collection is noninvasive, the test can be performed at home, one is not sample limited, and the stool effectively samples the entire length of the inner bowel wall contents (including tumor) as it passes down the gastrointestinal tract. Recent advances in mass spectrometry now facilitate both the targeted discovery and validation of potential CRC biomarkers. We describe, herein, detailed protocols that can be used to mine deeply into the fecal proteome to reveal candidate proteins, identify proteotypic/unitypic peptides (i.e., peptides found in only a single known human protein that serve to identify that protein) suitable for sensitive and specific quantitative multiplexed analysis, and undertake high-throughput analysis of clinical samples. Finally, we discuss future directions that may further position this technology to support the current switch in translation research toward personalized medicine.
Collapse
Affiliation(s)
- C S Ang
- Bio21 Molecular Science and Biotechnology Institute, University of Melbourne, Parkville, VIC, Australia
| | - M S Baker
- Faculty of Medicine and Health Sciences, Macquarie University, North Ryde, NSW, Australia
| | - E C Nice
- Monash University, Clayton, VIC, Australia.
| |
Collapse
|
41
|
Habchi B, Alves S, Paris A, Rutledge DN, Rathahao-Paris E. How to really perform high throughput metabolomic analyses efficiently? Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.09.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
42
|
Xiao K, Yu F, Tian Z. Top-down protein identification using isotopic envelope fingerprinting. J Proteomics 2016; 152:41-47. [PMID: 27989944 DOI: 10.1016/j.jprot.2016.10.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 10/11/2016] [Accepted: 10/23/2016] [Indexed: 12/14/2022]
Abstract
For top-down protein database search and identification from tandem mass spectra, our isotopic envelope fingerprinting search algorithm and ProteinGoggle search engine have demonstrated their strength of efficiently resolving heavily overlapping data as well separating non-ideal data with non-ideal isotopic envelopes from ideal ones with ideal isotopic envelopes. Here we report our updated ProteinGoggle 2.0 for intact protein database search with full-capacity. The indispensable updates include users' optional definition of dynamic post-translational modifications and static chemical labeling during database creation, comprehensive dissociation methods and ion series, as well as a Proteoform Score for each proteoform. ProteinGoggle has previously been benchmarked with both collision-based dissociation (CID, HCD) and electron-based dissociation (ETD) data of either intact proteins or intact proteomes. Here we report our further benchmarking of the new version of ProteinGoggle with publically available photon-based dissociation (UVPD) data (http://hdl.handle.net/2022/17316) of intact E. coli ribosomal proteins. BIOLOGICAL SIGNIFICANCE Protein species (aka proteoforms) function at their molecular level, and diverse structures and biological roles of every proteoform come from often co-occurring proteolysis, amino acid variation and post-translational modifications. Complete and high-throughput capture of this combinatorial information of proteoforms has become possible in evolving top-down proteomics; yet, various methods and technologies, especially database search and bioinformatics identification tools, in the top-down pipeline are still in their infancy stages and demand intensive research and development.
Collapse
Affiliation(s)
- Kaijie Xiao
- School of Chemical Science and Engineering, Tongji University, Shanghai, China; Shanghai Key Laboratory of Chemical Assessment and Sustainability, Tongji University, Shanghai, China
| | - Fan Yu
- School of Chemical Science and Engineering, Tongji University, Shanghai, China; Shanghai Key Laboratory of Chemical Assessment and Sustainability, Tongji University, Shanghai, China
| | - Zhixin Tian
- School of Chemical Science and Engineering, Tongji University, Shanghai, China; Shanghai Key Laboratory of Chemical Assessment and Sustainability, Tongji University, Shanghai, China.
| |
Collapse
|
43
|
Pröfrock D. Coupling Techniques and Orthogonal Combination of Mass Spectrometric Techniques. Metallomics 2016. [DOI: 10.1002/9783527694907.ch2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Daniel Pröfrock
- Helmholtz-Zentrum Geesthacht, Centre for Materials and Coastal Research; Department Marine Bioanalytical Chemistry, Institute of Coastal Research/Biogeochemistry in Coastal Seas; Max-Planck Str.1 21502 Geesthacht Germany
| |
Collapse
|
44
|
Liu YM, G. Nicolau B, Esbenshade JL, Gewirth AA. Characterization of the Cathode Electrolyte Interface in Lithium Ion Batteries by Desorption Electrospray Ionization Mass Spectrometry. Anal Chem 2016; 88:7171-7. [DOI: 10.1021/acs.analchem.6b01292] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Yao-Min Liu
- Department of Chemistry, University of Illinois, Urbana, Illinois 61801, United States
| | - Bruno G. Nicolau
- Department of Chemistry, University of Illinois, Urbana, Illinois 61801, United States
| | | | - Andrew A. Gewirth
- Department of Chemistry, University of Illinois, Urbana, Illinois 61801, United States
| |
Collapse
|
45
|
Abstract
Compared to genomics or transcriptomics, proteomics is often regarded as an "emerging technology," i.e., as not having reached the same level of maturity. While the successful implementation of proteomics workflows and technology still requires significant levels of expertise and specialization, great strides have been made to make the technology more powerful, streamlined and accessible. In 2014, two landmark studies published the first draft versions of the human proteome.We aim to provide an introduction specifically into the background of mass spectrometry (MS)-based proteomics. Within the field, mass spectrometry has emerged as a core technology. Coupled to increasingly powerful separations and data processing and bioinformatics solution, it allows the quantitative analysis of whole proteomes within a matter of days, a timescale that has made global comparative proteome studies feasible at last. We present and discuss the basic concepts behind proteomics mass spectrometry and the accompanying topic of protein and peptide separations, with a focus on the properties of datasets emerging from such studies.
Collapse
|
46
|
Prasse C, Ternes T. Application of Orbitrap Mass Spectrometry for the Identification of Transformation Products of Trace Organic Contaminants Formed in the Environment. APPLICATIONS OF TIME-OF-FLIGHT AND ORBITRAP MASS SPECTROMETRY IN ENVIRONMENTAL, FOOD, DOPING, AND FORENSIC ANALYSIS 2016. [DOI: 10.1016/bs.coac.2016.02.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
47
|
Dang Q, Xu F, Huang X, Fang X, Wang R, Ding CF. Linear ion trap with added octopole field component: the property and method. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:1400-1408. [PMID: 26634975 DOI: 10.1002/jms.3714] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Revised: 09/28/2015] [Accepted: 10/08/2015] [Indexed: 06/05/2023]
Abstract
It is well known that superimposition of some positive octopole field will benefit the performance of ion trap mass analyzer. In the radial-ejection linear ion trap (LIT), adding some octopole field component to the main quadrupole field is usually accomplished by stretching the ejection rod pair. In this study, the effect of octopole potential and some other higher order potential on the performance of LIT mass analyzer is investigated. A simple and effective method, which is to add some octopole component by building a LIT with a pair of rectangular electrodes and a pair of semi-circular electrodes, is reported. Its properties were studied by numerical simulations and experiments. The results showed that a certain amount of positive octopole component could be produced by simply adjusting the position and width of the rectangular electrodes. A resolution of over 1200 at m/z 609 (~1600 Da/s) was observed in this type of LIT. They also performed tandem mass spectrometry well. The device with optimum geometry for ion ejection from rectangular electrodes provided comparable performance to that for ion ejection from semi-circular electrodes. This type of LIT design is easy for fabrication and assembly.
Collapse
Affiliation(s)
- Qiankun Dang
- Shanghai Key Laboratory of Molecular Catalysis and Functional Material, Department of Chemistry and Laser Chemistry Institute, Fudan University, Shanghai, 200433, China
| | - Fuxing Xu
- Shanghai Key Laboratory of Molecular Catalysis and Functional Material, Department of Chemistry and Laser Chemistry Institute, Fudan University, Shanghai, 200433, China
| | - Xiaohua Huang
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, College of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210046, China
| | - Xiang Fang
- National Institute of Metrology, Beijing, China
| | - Rizhi Wang
- Shanghai Key Laboratory of Molecular Catalysis and Functional Material, Department of Chemistry and Laser Chemistry Institute, Fudan University, Shanghai, 200433, China
| | - Chuan-Fan Ding
- Shanghai Key Laboratory of Molecular Catalysis and Functional Material, Department of Chemistry and Laser Chemistry Institute, Fudan University, Shanghai, 200433, China
| |
Collapse
|
48
|
Lemonakis N, Skaltsounis AL, Tsarbopoulos A, Gikas E. Optimization of parameters affecting signal intensity in an LTQ-orbitrap in negative ion mode: A design of experiments approach. Talanta 2015; 147:402-9. [PMID: 26592625 DOI: 10.1016/j.talanta.2015.10.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Revised: 09/28/2015] [Accepted: 10/04/2015] [Indexed: 02/07/2023]
Abstract
A multistage optimization of all the parameters affecting detection/response in an LTQ-orbitrap analyzer was performed, using a design of experiments methodology. The signal intensity, a critical issue for mass analysis, was investigated and the optimization process was completed in three successive steps, taking into account the three main regions of an orbitrap, the ion generation, the ion transmission and the ion detection regions. Oleuropein and hydroxytyrosol were selected as the model compounds. Overall, applying this methodology the sensitivity was increased more than 24%, the resolution more than 6.5%, whereas the elapsed scan time was reduced nearly to its half. A high-resolution LTQ Orbitrap Discovery mass spectrometer was used for the determination of the analytes of interest. Thus, oleuropein and hydroxytyrosol were infused via the instruments syringe pump and they were analyzed employing electrospray ionization (ESI) in the negative high-resolution full-scan ion mode. The parameters of the three main regions of the LTQ-orbitrap were independently optimized in terms of maximum sensitivity. In this context, factorial design, response surface model and Plackett-Burman experiments were performed and analysis of variance was carried out to evaluate the validity of the statistical model and to determine the most significant parameters for signal intensity. The optimum MS conditions for each analyte were summarized and the method optimum condition was achieved by maximizing the desirability function. Our observation showed good agreement between the predicted optimum response and the responses collected at the predicted optimum conditions.
Collapse
Affiliation(s)
- Nikolaos Lemonakis
- Department of Pharmacognosy and Natural Products Chemistry, Faculty of Pharmacy, National and Kapodistrian University of Athens, 15771 Athens, Greece
| | - Alexios-Leandros Skaltsounis
- Department of Pharmacognosy and Natural Products Chemistry, Faculty of Pharmacy, National and Kapodistrian University of Athens, 15771 Athens, Greece
| | - Anthony Tsarbopoulos
- Department of Pharmacology, University of Athens Medical School, 11527 Athens, Greece
| | - Evagelos Gikas
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, National and Kapodistrian University of Athens, Panepistimioupolis Zografou, 15771 Athens, Greece.
| |
Collapse
|
49
|
Accurate and Efficient Resolution of Overlapping Isotopic Envelopes in Protein Tandem Mass Spectra. Sci Rep 2015; 5:14755. [PMID: 26439836 PMCID: PMC4593959 DOI: 10.1038/srep14755] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Accepted: 09/09/2015] [Indexed: 12/03/2022] Open
Abstract
It has long been an analytical challenge to accurately and efficiently resolve extremely dense overlapping isotopic envelopes (OIEs) in protein tandem mass spectra to confidently identify proteins. Here, we report a computationally efficient method, called OIE_CARE, to resolve OIEs by calculating the relative deviation between the ideal and observed experimental abundance. In the OIE_CARE method, the ideal experimental abundance of a particular overlapping isotopic peak (OIP) is first calculated for all the OIEs sharing this OIP. The relative deviation (RD) of the overall observed experimental abundance of this OIP relative to the summed ideal value is then calculated. The final individual abundance of the OIP for each OIE is the individual ideal experimental abundance multiplied by 1 + RD. Initial studies were performed using higher-energy collisional dissociation tandem mass spectra on myoglobin (with direct infusion) and the intact E. coli proteome (with liquid chromatographic separation). Comprehensive data at the protein and proteome levels, high confidence and good reproducibility were achieved. The resolving method reported here can, in principle, be extended to resolve any envelope-type overlapping data for which the corresponding theoretical reference values are available.
Collapse
|
50
|
Liu YM, Perry RH. Paper-Based Electrochemical Cell Coupled to Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:1702-1712. [PMID: 26311335 DOI: 10.1007/s13361-015-1224-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Revised: 06/15/2015] [Accepted: 06/17/2015] [Indexed: 06/04/2023]
Abstract
On-line coupling of electrochemistry (EC) to mass spectrometry (MS) is a powerful approach for identifying intermediates and products of EC reactions in situ. In addition, EC transformations have been used to increase ionization efficiency and derivatize analytes prior to MS, improving sensitivity and chemical specificity. Recently, there has been significant interest in developing paper-based electroanalytical devices as they offer convenience, low cost, versatility, and simplicity. This report describes the development of tubular and planar paper-based electrochemical cells (P-EC) coupled to sonic spray ionization (SSI) mass spectrometry (P-EC/SSI-MS). The EC cells are composed of paper sandwiched between two mesh stainless steel electrodes. Analytes and reagents can be added directly to the paper substrate along with electrolyte, or delivered via the SSI microdroplet spray. The EC cells are decoupled from the SSI source, allowing independent control of electrical and chemical parameters. We utilized P-EC/SSI-MS to characterize various EC reactions such as oxidations of cysteine, dopamine, polycyclic aromatic hydrocarbons, and diphenyl sulfide. Our results show that P-EC/SSI-MS has the ability to increase ionization efficiency, to perform online EC transformations, and to capture intermediates of EC reactions with a response time on the order of hundreds of milliseconds. The short response time allowed detection of a deprotonated diphenyl sulfide intermediate, which experimentally confirms a previously proposed mechanism for EC oxidation of diphenyl sulfide to pseudodimer sulfonium ion. This report introduces paper-based EC/MS via development of two device configurations (tubular and planar electrodes), as well as discusses the capabilities, performance, and limitations of the technique.
Collapse
Affiliation(s)
- Yao-Min Liu
- Department of Chemistry, University of Illinois, Urbana, IL, 61801, USA
| | - Richard H Perry
- Department of Chemistry, University of Illinois, Urbana, IL, 61801, USA.
| |
Collapse
|