1
|
Particle Diffusometry: An Optical Detection Method for Vibrio cholerae Presence in Environmental Water Samples. Sci Rep 2019; 9:1739. [PMID: 30741961 PMCID: PMC6370876 DOI: 10.1038/s41598-018-38056-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Accepted: 12/06/2018] [Indexed: 02/06/2023] Open
Abstract
There is a need for a rapid, robust, and sensitive biosensor to identify low concentrations of pathogens in their native sample matrix without enrichment or purification. Nucleic acid-based detection methods are widely accepted as the gold standard in diagnostics, but robust detection of low concentrations of pathogens remains challenging. Amplified nucleic acids produce more viscous solutions, which can be measured by combining these products with fluorescent particles and measuring the change in the particle diffusion coefficient using a technique known as particle diffusometry. Here, we utilize Vibrio cholerae (V. cholerae) as a proof-of-concept for our detection system due to its inherently low concentration in environmental water samples. We demonstrate that particle diffusometry can be used to detect down to 1 V. cholerae cell in molecular-grade water in 20 minutes and 10 V. cholerae cells in pond water in just 35 minutes in 25 µL reaction volumes. The detection limit in pond water is environmentally relevant and does not require any enrichment or sample preparation steps. Particle diffusometry is 10-fold more sensitive than current gold standard fluorescence detection of nucleic acid amplification. Therefore, this novel measurement technique is a promising approach to detect low levels of pathogens in their native environments.
Collapse
|
2
|
Ramage JG, Prentice KW, DePalma L, Venkateswaran KS, Chivukula S, Chapman C, Bell M, Datta S, Singh A, Hoffmaster A, Sarwar J, Parameswaran N, Joshi M, Thirunavkkarasu N, Krishnan V, Morse S, Avila JR, Sharma S, Estacio PL, Stanker L, Hodge DR, Pillai SP. Comprehensive Laboratory Evaluation of a Highly Specific Lateral Flow Assay for the Presumptive Identification of Bacillus anthracis Spores in Suspicious White Powders and Environmental Samples. Health Secur 2017; 14:351-65. [PMID: 27661796 DOI: 10.1089/hs.2016.0041] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
We conducted a comprehensive, multiphase laboratory evaluation of the Anthrax BioThreat Alert(®) test strip, a lateral flow immunoassay (LFA) for the rapid detection of Bacillus anthracis spores. The study, conducted at 2 sites, evaluated this assay for the detection of spores from the Ames and Sterne strains of B. anthracis, as well as those from an additional 22 strains. Phylogenetic near neighbors, environmental background organisms, white powders, and environmental samples were also tested. The Anthrax LFA demonstrated a limit of detection of about 10(6) spores/mL (ca. 1.5 × 10(5) spores/assay). In this study, overall sensitivity of the LFA was 99.3%, and the specificity was 98.6%. The results indicated that the specificity, sensitivity, limit of detection, dynamic range, and repeatability of the assay support its use in the field for the purpose of qualitatively evaluating suspicious white powders and environmental samples for the presumptive presence of B. anthracis spores.
Collapse
|
3
|
Ferrier DC, Shaver MP, Hands PJW. Micro- and nano-structure based oligonucleotide sensors. Biosens Bioelectron 2015; 68:798-810. [PMID: 25655465 DOI: 10.1016/j.bios.2015.01.031] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2014] [Revised: 01/12/2015] [Accepted: 01/13/2015] [Indexed: 12/26/2022]
Abstract
This paper presents a review of micro- and nano-structure based oligonucleotide detection and quantification techniques. The characteristics of such devices make them very attractive for Point-of-Care or On-Site-Testing biosensing applications. Their small scale means that they can be robust and portable, their compatibility with modern CMOS electronics means that they can easily be incorporated into hand-held devices and their suitability for mass production means that, out of the different approaches to oligonucleotide detection, they are the most suitable for commercialisation. This review discusses the advantages of micro- and nano-structure based sensors and covers the various oligonucleotide detection techniques that have been developed to date. These include: Bulk Acoustic Wave and Surface Acoustic Wave devices, micro- and nano-cantilever sensors, gene Field Effect Transistors, and nanowire and nanopore based sensors. Oligonucleotide immobilisation techniques are also discussed.
Collapse
Affiliation(s)
- David C Ferrier
- School of Engineering, University of Edinburgh, Edinburgh EH9 3JL, UK
| | - Michael P Shaver
- School of Chemistry, David Brewster Road, University of Edinburgh, Edinburgh EH9 3FJ, UK
| | - Philip J W Hands
- School of Engineering, University of Edinburgh, Edinburgh EH9 3JL, UK.
| |
Collapse
|
4
|
Vashist SK, Lam E, Hrapovic S, Male KB, Luong JHT. Immobilization of Antibodies and Enzymes on 3-Aminopropyltriethoxysilane-Functionalized Bioanalytical Platforms for Biosensors and Diagnostics. Chem Rev 2014; 114:11083-130. [DOI: 10.1021/cr5000943] [Citation(s) in RCA: 212] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Sandeep Kumar Vashist
- HSG-IMIT - Institut für Mikro- und Informationstechnik, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
- Laboratory for MEMS Applications, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - Edmond Lam
- National Research Council Canada, Montreal, Quebec H4P 2R2, Canada
| | | | - Keith B. Male
- National Research Council Canada, Montreal, Quebec H4P 2R2, Canada
| | - John H. T. Luong
- Innovative Chromatography Group, Irish Separation Science Cluster (ISSC), Department of Chemistry and Analytical, Biological Chemistry Research Facility (ABCRF), University College Cork, Cork, Ireland
| |
Collapse
|
5
|
Atomic force microscopy in microbiology: new structural and functional insights into the microbial cell surface. mBio 2014; 5:e01363-14. [PMID: 25053785 PMCID: PMC4120197 DOI: 10.1128/mbio.01363-14] [Citation(s) in RCA: 114] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Microbial cells sense and respond to their environment using their surface constituents. Therefore, understanding the assembly and biophysical properties of cell surface molecules is an important research topic. With its ability to observe living microbial cells at nanometer resolution and to manipulate single-cell surface molecules, atomic force microscopy (AFM) has emerged as a powerful tool in microbiology. Here, we survey major breakthroughs made in cell surface microbiology using AFM techniques, emphasizing the most recent structural and functional insights.
Collapse
|
6
|
Osmekhina E, Shvetsova A, Ruottinen M, Neubauer P. Quantitative and sensitive RNA based detection of Bacillus spores. Front Microbiol 2014; 5:92. [PMID: 24653718 PMCID: PMC3949131 DOI: 10.3389/fmicb.2014.00092] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2014] [Accepted: 02/19/2014] [Indexed: 11/13/2022] Open
Abstract
The fast and reliable detection of bacterial spores is of great importance and still remains a challenge. Here we describe a direct RNA-based diagnostic method for the specific detection of viable bacterial spores which does not depends on an enzymatic amplification step and therefore is directly appropriate for quantification. The procedure includes the following steps: (i) heat activation of spores, (ii) germination and enrichment cultivation, (iii) cell lysis, and (iv) analysis of 16S rRNA in crude cell lysates using a sandwich hybridization assay. The sensitivity of the method is dependent on the cultivation time and the detection limit; it is possible to detect 10 spores per ml when the RNA analysis is performed after 6 h of enrichment cultivation. At spore concentrations above 10(6) spores per ml the cultivation time can be shortened to 30 min. Total analysis times are in the range of 2-8 h depending on the spore concentration in samples. The developed procedure is optimized at the example of Bacillus subtilis spores but should be applicable to other organisms. The new method can easily be modified for other target RNAs and is suitable for specific detection of spores from known groups of organisms.
Collapse
Affiliation(s)
- Ekaterina Osmekhina
- Department of Process and Environmental Engineering and Biocenter Oulu, University of Oulu Oulu, Finland
| | - Antonina Shvetsova
- Department of Biochemistry and Biocenter Oulu, University of Oulu Oulu, Finland
| | - Maria Ruottinen
- Department of Process and Environmental Engineering and Biocenter Oulu, University of Oulu Oulu, Finland
| | - Peter Neubauer
- Department of Process and Environmental Engineering and Biocenter Oulu, University of Oulu Oulu, Finland ; Laboratory of Bioprocess Engineering, Department of Biotechnology, Technische Universität Berlin Berlin, Germany
| |
Collapse
|
7
|
Xu D, Liu L, Guan J, Xu J, Wang T, Qin A, Hu X, Wang C. Label-free microcantilever-based immunosensors for highly sensitive determination of avian influenza virus H9. Mikrochim Acta 2013. [PMCID: PMC7087674 DOI: 10.1007/s00604-013-1129-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Affiliation(s)
- Dan Xu
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002 China
| | - Lin Liu
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002 China
| | - Jun Guan
- Clinical College of Yangzhou University, Subei People’s Hospital of Jiangsu Province, Yangzhou, 225002 China
| | - Jianyun Xu
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002 China
| | - Ting Wang
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002 China
| | - Aijian Qin
- College of Veterinary Medicine, Yangzhou University, Yangzhou, 225002 China
| | - Xiaoya Hu
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002 China
- Jiangsu Key Laboratory of Environmental Engineering and Monitoring, Yangzhou, 225002 China
| | - Chengyin Wang
- College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002 China
- Jiangsu Key Laboratory of Environmental Engineering and Monitoring, Yangzhou, 225002 China
| |
Collapse
|
8
|
Calleja M, Kosaka PM, San Paulo Á, Tamayo J. Challenges for nanomechanical sensors in biological detection. NANOSCALE 2012; 4:4925-4938. [PMID: 22810853 DOI: 10.1039/c2nr31102j] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Nanomechanical biosensing relies on changes in the movement and deformation of micro- and nanoscale objects when they interact with biomolecules and other biological targets. This field of research has provided ever-increasing records in the sensitivity of label-free detection but it has not yet been established as a practical alternative for biological detection. We analyze here the latest advancements in the field, along with the challenges remaining for nanomechanical biosensors to become a commonly used tool in biology and biochemistry laboratories.
Collapse
Affiliation(s)
- Montserrat Calleja
- Institute of Microelectronics of Madrid, CSIC, Isaac Newton 8 (PTM), Tres Cantos, 28760 Madrid, Spain.
| | | | | | | |
Collapse
|
9
|
Singh A, Arutyunov D, Szymanski CM, Evoy S. Bacteriophage based probes for pathogen detection. Analyst 2012; 137:3405-21. [PMID: 22724121 DOI: 10.1039/c2an35371g] [Citation(s) in RCA: 107] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Rapid and specific detection of pathogenic bacteria is important for the proper treatment, containment and prevention of human, animal and plant diseases. Identifying unique biological probes to achieve a high degree of specificity and minimize false positives has therefore garnered much interest in recent years. Bacteriophages are obligate intracellular parasites that subvert bacterial cell resources for their own multiplication and production of disseminative new virions, which repeat the cycle by binding specifically to the host surface receptors and injecting genetic material into the bacterial cells. The precision of host recognition in phages is imparted by the receptor binding proteins (RBPs) that are often located in the tail-spike or tail fiber protein assemblies of the virions. Phage host recognition specificity has been traditionally exploited for bacterial typing using laborious and time consuming bacterial growth assays. At the same time this feature makes phage virions or RBPs an excellent choice for the development of probes capable of selectively capturing bacteria on solid surfaces with subsequent quick and automatic detection of the binding event. This review focuses on the description of pathogen detection approaches based on immobilized phage virions as well as pure recombinant RBPs. Specific advantages of RBP-based molecular probes are also discussed.
Collapse
Affiliation(s)
- Amit Singh
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 2V4, Canada.
| | | | | | | |
Collapse
|
10
|
Göransson J, Ke R, Nong RY, Howell WM, Karman A, Grawé J, Stenberg J, Granberg M, Elgh M, Herthnek D, Wikström P, Jarvius J, Nilsson M. Rapid identification of bio-molecules applied for detection of biosecurity agents using rolling circle amplification. PLoS One 2012; 7:e31068. [PMID: 22383994 PMCID: PMC3285169 DOI: 10.1371/journal.pone.0031068] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2011] [Accepted: 01/01/2012] [Indexed: 11/22/2022] Open
Abstract
Detection and identification of pathogens in environmental samples for biosecurity applications are challenging due to the strict requirements on specificity, sensitivity and time. We have developed a concept for quick, specific and sensitive pathogen identification in environmental samples. Target identification is realized by padlock- and proximity probing, and reacted probes are amplified by RCA (rolling-circle amplification). The individual RCA products are labeled by fluorescence and enumerated by an instrument, developed for sensitive and rapid digital analysis. The concept is demonstrated by identification of simili biowarfare agents for bacteria (Escherichia coli and Pantoea agglomerans) and spores (Bacillus atrophaeus) released in field.
Collapse
Affiliation(s)
- Jenny Göransson
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
- Q-linea AB, Dag Hammarskjölds, Uppsala, Sweden
| | - Rongqin Ke
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
| | - Rachel Yuan Nong
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
| | - W. Mathias Howell
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
| | - Anna Karman
- Olink AB, Dag Hammarskjölds väg, Uppsala, Sweden
- Q-linea AB, Dag Hammarskjölds, Uppsala, Sweden
| | - Jan Grawé
- Q-linea AB, Dag Hammarskjölds, Uppsala, Sweden
| | | | | | - Magnus Elgh
- Q-linea AB, Dag Hammarskjölds, Uppsala, Sweden
| | - David Herthnek
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
| | | | - Jonas Jarvius
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
- Q-linea AB, Dag Hammarskjölds, Uppsala, Sweden
| | - Mats Nilsson
- the Rudbeck Laboratory, Department of Immunology, Genetics and Pathology, SciLifeLab, Uppsala University, Uppsala, Sweden
| |
Collapse
|
11
|
Capobianco JA, Shih WY, Adams GP, Shih WH. Label-free Growth Receptor-2 Detection and Dissociation Constant Assessment in Diluted Human Serum Using a Longitudinal Extension Mode of a Piezoelectric Microcantilever Sensor. SENSORS AND ACTUATORS. B, CHEMICAL 2011; 160:349-356. [PMID: 22888196 PMCID: PMC3413307 DOI: 10.1016/j.snb.2011.07.060] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
We have investigated real-time, label-free, in-situ detection of human epidermal growth factor receptor 2 (Her2) in diluted serum using the first longitudinal extension mode of a lead zirconate-lead titanate (PZT)/glass piezoelectric microcantilever sensor (PEMS) with H3 single-chain variable fragment (scFv) immobilized on the 3-mercaptopropyltrimethoxysilane (MPS) insulation layer of the PEMS surface. We showed that with the longitudinal extension mode, the PZT/glass PEMS consisting of a 1 mm long and 127 μm thick PZT layer bonded with a 75 μm thick glass layer with a 1.8 mm long glass tip could detect Her2 at a concentration of 6-60 ng/ml (or 0.06-0.6 nM) in diluted human serum, about 100 times lower than the concentration limit obtained using the lower-frequency flexural mode of a similar PZT/glass PEMS. We further showed that with the longitudinal mode, the PZT/glass PEMS determined the equilibrium H3-Her2 dissociation constant K(d) to be 3.3±0.3 × 10(-8) M consistent with the value, 3.2±0.28 ×10(-8) M deduced by the surface plasmon resonance method (BIAcore).
Collapse
Affiliation(s)
- Joseph A Capobianco
- Department of Materials Science and Engineering, Drexel University, Philadelphia, PA 19104
| | | | | | | |
Collapse
|
12
|
Johnson BN, Mutharasan R. Biosensing using dynamic-mode cantilever sensors: a review. Biosens Bioelectron 2011; 32:1-18. [PMID: 22119230 DOI: 10.1016/j.bios.2011.10.054] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2011] [Revised: 10/25/2011] [Accepted: 10/27/2011] [Indexed: 01/26/2023]
Abstract
Current progress on the use of dynamic-mode cantilever sensors for biosensing applications is critically reviewed. We summarize their use in biosensing applications to date with focus given to: cantilever size (milli-, micro-, and nano-cantilevers), their geometry, and material used in fabrication. The review also addresses techniques investigated for both exciting and measuring cantilever resonance in various environments (vacuum, air, and liquid). Biological targets that have been detected to date are summarized with attention to bio-recognition chemistry, surface functionalization method, limit of detection, resonant frequency mode type, and resonant frequency measurement scheme. Applications published to date are summarized in a comprehensive table with description of the aforementioned details including comparison of sensitivities. Further, the general theory of cantilever resonance is discussed including fluid-structure interaction and its dependence on the Reynolds number for Newtonian fluids. The review covers designs with frequencies ranging from ∼1 kHz to 10 MHz and cantilever size ranging from millimeters to nanometers. We conclude by identifying areas that require further investigation.
Collapse
Affiliation(s)
- Blake N Johnson
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, PA 19104, United States
| | | |
Collapse
|
13
|
Buchapudi KR, Huang X, Yang X, Ji HF, Thundat T. Microcantilever biosensors for chemicals and bioorganisms. Analyst 2011; 136:1539-56. [PMID: 21394347 DOI: 10.1039/c0an01007c] [Citation(s) in RCA: 88] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
In the last fifteen years, microcantilevers (MCLs) have been emerging as a sensitive tool for the detection of chemicals and bioorganisms. Because of their small size, lightweight, and high surface-to-volume ratio, MCL-based sensors improve our capability to detect and identify biological agents by orders of magnitude. A biosensor is a device for the detection of an analyte that combines a biological component with a physicochemical detector component. The MCL biosensors have recently been reviewed in several papers. All of these papers were organized based on the sensing biological elements (antibody, enzyme, proteins, etc.) for recognition of analytes. In this review, we intend to summarize the microcantilever biosensors in a format of each specific chemical and bioorganism species to make information on individual biosensors easily accessible. We did this to aid researchers to locate relevant references.
Collapse
Affiliation(s)
- Koutilya R Buchapudi
- Institute for Micromanufacturing, Louisiana Tech University, Ruston, LA 71272, USA
| | | | | | | | | |
Collapse
|
14
|
Ding Y, Mutharasan R. Highly sensitive and rapid detection of microcystin-LR in source and finished water samples using cantilever sensors. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2011; 45:1490-1496. [PMID: 21189000 DOI: 10.1021/es1020795] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Microcystin-leucine-arginine (MCLR) is one of the toxic microcystin congeners produced by the common cyanobacteria, blue-green algae. A piezoelectric-excited millimeter-sized cantilever (PEMC) sensor was developed for the sensitive detection of MCLR in a flow format using both monoclonal and polyclonal antibodies that bind specifically to MCLR. PEMC is a resonant cantilever sensor whose resonant frequency decreases as target analyte binds to its surface. Monoclonal antibody against MCLR was immobilized on the sensor surface via amine coupling. As the toxin in the sample water bound to the antibody, resonant frequency decreased proportional to toxin concentration. Three water matrices, namely buffer, tap water, and river water, were spiked with MCLR standards and were successfully detected in the dynamic range of 1 pg/mL to 100 ng/mL (effective concentration -250 fg/mL to 25 ng/mL). The sensor response was characterized by a log-linear relationship between resonant frequency change and MCLR concentration. Positive verification of MCLR detection was confirmed by a sandwich binding on the sensor with a second antibody binding to MCLR on the sensor (attached in first detection step) which caused a further resonant frequency decrease. We show for the first time that MCLR in various water samples can be detected at 1 pg/mL.
Collapse
Affiliation(s)
- Yanjun Ding
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, PA 19104, USA
| | | |
Collapse
|
15
|
Lopez CA, Daaboul GG, Vedula RS, Ozkumur E, Bergstein DA, Geisbert TW, Fawcett HE, Goldberg BB, Connor JH, Unlü MS. Label-free multiplexed virus detection using spectral reflectance imaging. Biosens Bioelectron 2011; 26:3432-7. [PMID: 21342761 DOI: 10.1016/j.bios.2011.01.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2010] [Revised: 12/21/2010] [Accepted: 01/14/2011] [Indexed: 10/18/2022]
Abstract
We demonstrate detection of whole viruses and viral proteins with a new label-free platform based on spectral reflectance imaging. The Interferometric Reflectance Imaging Sensor (IRIS) has been shown to be capable of sensitive protein and DNA detection in a real time and high-throughput format. Vesicular stomatitis virus (VSV) was used as the target for detection as it is well-characterized for protein composition and can be modified to express viral coat proteins from other dangerous, highly pathogenic agents for surrogate detection while remaining a biosafety level 2 agent. We demonstrate specific detection of intact VSV virions achieved with surface-immobilized antibodies acting as capture probes which is confirmed using fluorescence imaging. The limit of detection is confirmed down to 3.5 × 10(5)plaque-forming units/mL (PFUs/mL). To increase specificity in a clinical scenario, both the external glycoprotein and internal viral proteins were simultaneously detected with the same antibody arrays with detergent-disrupted purified VSV and infected cell lysate solutions. Our results show sensitive and specific virus detection with a simple surface chemistry and minimal sample preparation on a quantitative label-free interferometric platform.
Collapse
Affiliation(s)
- Carlos A Lopez
- Department of Electrical & Computer Engineering, Boston University, Boston, MA 02215, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Xu S, Mutharasan R. Cell Viability Measurement Using 2′,7′-Bis-(2-carboxyethyl)-5-(and-6)-carboxyfluorescein Acetoxymethyl Ester and a Cantilever Sensor. Anal Chem 2011; 83:1480-3. [DOI: 10.1021/ac102757q] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Sen Xu
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, Pennsylvania 19104, United States
| | - Raj Mutharasan
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, Pennsylvania 19104, United States
| |
Collapse
|
17
|
Li D, Feng Y, Zhou L, Ye Z, Wang J, Ying Y, Ruan C, Wang R, Li Y. Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7. Anal Chim Acta 2010; 687:89-96. [PMID: 21241851 DOI: 10.1016/j.aca.2010.12.018] [Citation(s) in RCA: 73] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2010] [Revised: 10/29/2010] [Accepted: 12/10/2010] [Indexed: 12/25/2022]
Abstract
A label-free capacitive immunosensor based on quartz crystal Au electrode was developed for rapid and sensitive detection of Escherichia coli O157:H7. The immunosensor was fabricated by immobilizing affinity-purified anti-E. coli O157:H7 antibodies onto self-assembled monolayers (SAMs) of 3-mercaptopropionic acid (MPA) on the surface of a quartz crystal Au electrode. Bacteria suspended in solution became attached to the immobilized antibodies when the immunosensor was tested in liquid samples. The change in capacitance caused by the bacteria was directly measured by an electrochemical detector. An equivalent circuit was introduced to simulate the capacitive immunosensor. The immunosensor was evaluated for E. coli O157:H7 detection in pure culture and inoculated food samples. The experimental results indicated that the capacitance change was linearly correlated with the cell concentration of E. coli O157:H7. The immunosensor was able to discriminate between cellular concentrations of 10(2)-10(5) cfu mL(-1) and has applications in detecting pathogens in food samples. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were also employed to characterize the stepwise assembly of the immunosensor.
Collapse
Affiliation(s)
- Dujuan Li
- College of Biosystems Engineering and Food Science, Zhejiang University, 268 Kaixuan Road, Hangzhou 310029, China
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Detection technologies for Bacillus anthracis: Prospects and challenges. J Microbiol Methods 2010; 82:1-10. [DOI: 10.1016/j.mimet.2010.04.005] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2010] [Revised: 04/09/2010] [Accepted: 04/12/2010] [Indexed: 01/20/2023]
|
19
|
Detection of Cryptosporidium parvum in buffer and in complex matrix using PEMC sensors at 5oocystsmL−1. Anal Chim Acta 2010; 669:81-6. [DOI: 10.1016/j.aca.2010.04.056] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2009] [Revised: 04/23/2010] [Accepted: 04/26/2010] [Indexed: 11/19/2022]
|
20
|
Xu S, Sharma H, Mutharasan R. Sensitive and selective detection of mycoplasma in cell culture samples using cantilever sensors. Biotechnol Bioeng 2010; 105:1069-77. [PMID: 20014143 DOI: 10.1002/bit.22637] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this article we report a new biosensor-based method that is more sensitive and rapid than the current approach for detecting mycoplasma in cell culture samples. Piezoelectric-excited millimeter-sized cantilever (PEMC) sensors respond to mass change via resonant frequency change. They are sensitive at femtogram level and can be used directly in liquid for label-free detection. Common cell culture contaminant, Acholeplasma laidlawii was detected in both buffer and cell culture medium. Two different sources (positive control from a commercial kit and ATCC 23206) were analyzed using antibody-immobilized PEMC sensor. Resonant frequency decrease caused by binding of A. laidlawii was monitored in real-time using an impedance analyzer. Positive detection was confirmed by a second antibody binding. The limit of detection (LOD) was lower than 10(3) CFU/mL in cell culture medium using PEMC sensor while parallel ELISA assays showed LOD as 10(7) CFU/mL. This study shows that PEMC sensor can be used for sensitive and rapid mycoplasma detection in cell culture samples.
Collapse
Affiliation(s)
- Sen Xu
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, PA 19104, USA
| | | | | |
Collapse
|
21
|
Xu S, Mutharasan R. Rapid and sensitive detection of Giardia lamblia using a piezoelectric cantilever biosensor in finished and source waters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2010; 44:1736-1741. [PMID: 20121270 DOI: 10.1021/es9033843] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The current method for detecting the waterborne parasite Giardia lamblia is tedious and requires a preconcentration step. We show for the first time a piezoelectric-excited millimeter-sized cantilever (PEMC) biosensor immobilized with a monoclonal antibody against G. lamblia that exhibits selective and sensitive detection of G. lamblia cysts in several water matrixes (buffer, tap, and river water) at a detection limit of 1-10 cysts/mL without a preconcentration step. The PEMC sensor is a resonance-based device that functions at a high-order mode near 1 MHz. The antibody-immobilized sensor was exposed to 1-10,000 G. lamblia cysts/mL samples in a flow arrangement. When the cysts bind to the antibody on the sensor, the resonant frequency of the cantilever sensor decreases and is recorded continuously. Positive confirmation of sensor detection responses was obtained by environmental scanning electron microscope of sensor surface after detection experiments. Higher sample flow rates (0.5-5.0 mL/min) gave higher sensor detection response. Detecting as few as 10 cysts per mL was achieved in all three water matrixes tested, and significant sensor response was obtained in 15 min. We also show the feasibility of analyzing at a low concentration of 1 cyst/mL in a one liter sample at a high flow rate of 5 mL/min.
Collapse
Affiliation(s)
- Sen Xu
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, Pennsylvania 19104, USA
| | | |
Collapse
|
22
|
Implications of limits of detection of various methods for Bacillus anthracis in computing risks to human health. Appl Environ Microbiol 2009; 75:6331-9. [PMID: 19648357 DOI: 10.1128/aem.00288-09] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Used for decades for biological warfare, Bacillus anthracis (category A agent) has proven to be highly stable and lethal. Quantitative risk assessment modeling requires descriptive statistics of the limit of detection to assist in defining the exposure. Furthermore, the sensitivities of various detection methods in environmental matrices are vital information for first responders. A literature review of peer-reviewed journal articles related to methods for detection of B. anthracis was undertaken. Articles focused on the development or evaluation of various detection approaches, such as PCR, real-time PCR, immunoassay, etc. Real-time PCR and PCR were the most sensitive methods for the detection of B. anthracis, with median instrument limits of detection of 430 and 440 cells/ml, respectively. There were very few peer-reviewed articles on the detection methods for B. anthracis in the environment. The most sensitive limits of detection for the environmental samples were 0.1 CFU/g for soil using PCR-enzyme-linked immunosorbent assay (ELISA), 17 CFU/liter for air using an ELISA-biochip system, 1 CFU/liter for water using cultivation, and 1 CFU/cm(2) for stainless steel fomites using cultivation. An exponential dose-response model for the inhalation of B. anthracis estimates of risk at concentrations equal to the environmental limit of detection determined the probability of death if untreated to be as high as 0.520. Though more data on the environmental limit of detection would improve the assumptions made for the risk assessment, this study's quantification of the risk posed by current limitations in the knowledge of detection methods should be considered when employing those methods in environmental monitoring and cleanup strategies.
Collapse
|
23
|
Antibody-based sensors: principles, problems and potential for detection of pathogens and associated toxins. SENSORS 2009; 9:4407-45. [PMID: 22408533 PMCID: PMC3291918 DOI: 10.3390/s90604407] [Citation(s) in RCA: 199] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2009] [Revised: 05/26/2009] [Accepted: 05/26/2009] [Indexed: 01/30/2023]
Abstract
Antibody-based sensors permit the rapid and sensitive analysis of a range of pathogens and associated toxins. A critical assessment of the implementation of such formats is provided, with reference to their principles, problems and potential for 'on-site' analysis. Particular emphasis is placed on the detection of foodborne bacterial pathogens, such as Escherichia coli and Listeria monocytogenes, and additional examples relating to the monitoring of fungal pathogens, viruses, mycotoxins, marine toxins and parasites are also provided.
Collapse
|
24
|
Abstract
At the cross-roads of nanoscience and microbiology, the nanoscale analysis of microbial cells using atomic force microscopy (AFM) is an exciting, rapidly evolving research field. Over the past decade, there has been tremendous progress in our use of AFM to observe membrane proteins and live cells at high resolution. Remarkable advances have also been made in applying force spectroscopy to manipulate single membrane proteins, to map surface properties and receptor sites on cells and to measure cellular interactions at the single-cell and single-molecule levels. In addition, recent developments in cantilever nanosensors have opened up new avenues for the label-free detection of microorganisms and bioanalytes.
Collapse
Affiliation(s)
- Yves F Dufrêne
- Unité de chimie des interfaces, Université catholique de Louvain, Croix du Sud 2/18, B-1348 Louvain-la-Neuve, Belgium.
| |
Collapse
|
25
|
Abstract
In this chapter, method of fabricating a cantilever biosensors and their use in measuring the presence of a protein is described. There are many variations in construction of a cantilever sensor. A simple and an easy version is described in this chapter. The specificity of the sensor is obtained by immobilizing an antibody specific to the antigen of interest. The piezoelectric cantilever sensors are very sensitive and can easily detect a 60 kDa protein at 100 fg/mL concentration. Experimental procedure for carrying out detection of a target analyte is outlined and a sample set of results is included.
Collapse
Affiliation(s)
- Raj Mutharasan
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, PA, USA
| |
Collapse
|
26
|
Hwang KS, Lee SM, Kim SK, Lee JH, Kim TS. Micro- and nanocantilever devices and systems for biomolecule detection. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2009; 2:77-98. [PMID: 20636054 DOI: 10.1146/annurev-anchem-060908-155232] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Recent research trends in biosensing have been geared toward developing bioanalytical devices that are label free, small in size, and portable and that can operate in a rapid manner. The performance of these devices has been dramatically improved through the advent of new materials and micro-/nanofabrication technologies. This is especially true for micro-/nanosized cantilever sensors, which undergo a change in mechanical properties upon the specific binding of biomolecules. In this review, we introduce the basic principles of cantilever biosensors in static and dynamic modes. We also summarize a range of approaches to cantilever design, fabrication, and instrumentation according to their applications. More specifically, we describe cantilever-based detections of proteins, DNA molecules, bacteria, and viruses and discuss current challenges related to the targets' biophysical characteristics.
Collapse
Affiliation(s)
- Kyo Seon Hwang
- Nano-Bio Research Center, Korea Institute of Science and Technology, Seoul 136-791, Republic of Korea
| | | | | | | | | |
Collapse
|
27
|
|
28
|
Goeders KM, Colton JS, Bottomley LA. Microcantilevers: Sensing Chemical Interactions via Mechanical Motion. Chem Rev 2008; 108:522-42. [DOI: 10.1021/cr0681041] [Citation(s) in RCA: 269] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
29
|
Near real-time detection of Cryptosporidium parvum oocyst by IgM-functionalized piezoelectric-excited millimeter-sized cantilever biosensor. Biosens Bioelectron 2008; 23:1039-45. [DOI: 10.1016/j.bios.2007.10.017] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2007] [Revised: 09/11/2007] [Accepted: 10/23/2007] [Indexed: 11/18/2022]
|
30
|
Maraldo D, Mutharasan R. Preparation-free method for detecting Escherichia coli O157:H7 in the presence of spinach, spring lettuce mix, and ground beef particulates. J Food Prot 2007; 70:2651-5. [PMID: 18044451 DOI: 10.4315/0362-028x-70.11.2651] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We show the detection of 100 cells per ml of Escherichia coli O157:H7 in the presence of spinach, spring lettuce mix, and ground beef washes and particulate matter with piezoelectric-excited millimeter-sized cantilever (PEMC) sensors. The PEMC sensors (sensing area, 2 mm2) were immobilized with polyclonal antibody specific to E. coli O157:H7 (EC) and were exposed to 10 aqueous washes of locally purchased spinach, spring lettuce mix, and ground beef for testing if EC was present. Absence of resonance frequency shift indicated that EC was not present in the 30 samples tested. Following the last sample in each food matrix, 1,000 cells per ml of EC were spiked into the sample container, and resonance frequency change was monitored. The total resonance frequency change was 880 +/- 5, 1,875 +/- 8, and 1,417 +/- 4 Hz for spinach, spring lettuce mix, and ground beef, respectively. A mixture of the three food matrices spiked with 100 cells per ml of EC gave a sensor response of 260 +/- 15 Hz. The resonance frequency changes are approximately 40% lower than our previously reported study on ground beef. It is suggested that the reduction in sensitivity is due to differences in pathogen adherence to food matrices, which affects target binding to the sensor surface. We conclude that detection selectivity is conserved in the three food matrices examined and that the magnitude of sensor response is a function of the food matrix.
Collapse
Affiliation(s)
- David Maraldo
- Department of Chemical Engineering, Drexel University, Philadelphia, Pennsylvania 19104, USA
| | | |
Collapse
|
31
|
Maraldo D, Rijal K, Campbell G, Mutharasan R. Method for Label-Free Detection of Femtogram Quantities of Biologics in Flowing Liquid Samples. Anal Chem 2007; 79:2762-70. [PMID: 17309231 DOI: 10.1021/ac0621726] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Rapid (approximately 10 min) measurement of very low concentration of pathogens (approximately 10 cells/mL) and protein (approximately fg/mL) has widespread use in medical diagnostics, monitoring biothreat agents, and in a broader context as a research method. For low-level pathogen, we currently use culture enrichment methods and, thus, rapid analysis is not possible. For low protein concentration, no direct method is currently available. We report here a novel macrocantilever design whose high-order resonant mode near 1 MHz exhibits mass detection sensitivity of 10 cells/mL for cells and 100 fg/mL for protein. The sensor is 1x3 mm and uses a piezoelectric layer for both actuation and sensing resonance. Sample is flowed (approximately 1 mL/min) past the antibody-immobilized sensor, and as antigen binds to the sensor, resonance frequency decreases in proportion to antigen concentration. The sensor showed selectivity to the pathogen even though copious nonpathogenic variant was simultaneously present.
Collapse
Affiliation(s)
- David Maraldo
- Department of Chemical and Biological Engineering, Drexel University, Philadelphia, Pennsylvania 19104, USA
| | | | | | | |
Collapse
|