1
|
Xu L, Zhong L, Tang Y, Han T, Liu S, Sun Z, Bao Y, Wang H, He Y, Wang W, Gan S, Niu L. Beyond Nonactin: Potentiometric Ammonium Ion Sensing Based on Ion-selective Membrane-free Prussian Blue Analogue Transducers. Anal Chem 2022; 94:10487-10496. [PMID: 35839308 DOI: 10.1021/acs.analchem.2c01765] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The determination of ammonium ions (NH4+) is of significance to environmental, agriculture, and human health. Potentiometric NH4+ sensors based on solid-contact ion selective electrodes (SC-ISEs) feature point-of-care testing and miniaturization. However, the state-of-the-art SC-ISEs of NH4+ during the past 20 years strongly rely on the organic ammonium ionophore-based ion selective membrane (ISM), typically by nonactin for the NH4+ recognition. Herein, we report a Prussian blue analogue of copper(II)-hexacyanoferrate (CuHCF) for an ISM-free potentiometric NH4+ sensor without using the ionophores. CuHCF works as a bifunctional transducer that could realize the ion-to-electron transduction and NH4+ recognition. CuHCF exhibits competitive analytical performances regarding traditional nonactin-based SC-ISEs of NH4+, particularly for the selectivity toward K+. The cost and preparation process have been remarkably reduced. The theoretical calculation combined with electrochemical tests further demonstrate that relatively easier intercalation of NH4+ into the lattices of CuHCF determines its selectivity. This work provides a concept of the ISM-free potentiometric NH4+ sensor beyond the nonactin ionophore through a CuHCF bifunctional transducer.
Collapse
Affiliation(s)
- Longbin Xu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Lijie Zhong
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yitian Tang
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Tingting Han
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Siyi Liu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Zhonghui Sun
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Yu Bao
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Haoyu Wang
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Ying He
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Wei Wang
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Shiyu Gan
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| | - Li Niu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, c/o School of Civil Engineering, Guangzhou University, Guangzhou 510006, P. R. China
| |
Collapse
|
2
|
Liao C, Zhong L, Tang Y, Sun Z, Lin K, Xu L, Lyu Y, He D, He Y, Ma Y, Bao Y, Gan S, Niu L. Solid-Contact Potentiometric Anion Sensing Based on Classic Silver/Silver Insoluble Salts Electrodes without Ion-Selective Membrane. MEMBRANES 2021; 11:959. [PMID: 34940460 PMCID: PMC8707216 DOI: 10.3390/membranes11120959] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/27/2021] [Accepted: 11/28/2021] [Indexed: 12/27/2022]
Abstract
Current solid potentiometric ion sensors mostly rely on polymeric-membrane-based, solid-contact, ion-selective electrodes (SC-ISEs). However, anion sensing has been a challenge with respect to cations due to the rareness of anion ionophores. Classic metal/metal insoluble salt electrodes (such as Ag/AgCl) without an ion-selective membrane (ISM) offer an alternative. In this work, we first compared the two types of SC-ISEs of Cl- with/without the ISM. It is found that the ISM-free Ag/AgCl electrode discloses a comparable selectivity regarding organic chloride ionophores. Additionally, the electrode exhibits better comprehensive performances (stability, reproducibility, and anti-interference ability) than the ISM-based SC-ISE. In addition to Cl-, other Ag/AgX electrodes also work toward single and multi-valent anions sensing. Finally, a flexible Cl- sensor was fabricated for on-body monitoring the concentration of sweat Cl- to illustrate a proof-of-concept application in wearable anion sensors. This work re-emphasizes the ISM-free SC-ISEs for solid anion sensing.
Collapse
Affiliation(s)
- Chunxian Liao
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Lijie Zhong
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Yitian Tang
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
- School of Civil Engineering, Guangzhou University, Guangzhou 510006, China
| | - Zhonghui Sun
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Kanglong Lin
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Longbin Xu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
- School of Civil Engineering, Guangzhou University, Guangzhou 510006, China
| | - Yan Lyu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
- School of Civil Engineering, Guangzhou University, Guangzhou 510006, China
| | - Dequan He
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Ying He
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Yingming Ma
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Yu Bao
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Shiyu Gan
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| | - Li Niu
- Guangzhou Key Laboratory of Sensing Materials & Devices, Center for Advanced Analytical Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (C.L.); (L.Z.); (Y.T.); (Z.S.); (K.L.); (L.X.); (Y.L.); (D.H.); (Y.H.); (Y.M.); (Y.B.); (L.N.)
| |
Collapse
|
3
|
PAS1-modified optical SIS sensor for highly sensitive and specific detection of toluene. Biosens Bioelectron 2019; 141:111469. [PMID: 31260905 DOI: 10.1016/j.bios.2019.111469] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 06/18/2019] [Accepted: 06/22/2019] [Indexed: 11/23/2022]
Abstract
We report on a novel solution immersed silicon (SIS) sensor modified with bio-receptor to detect toluene. To perform this approach, bio-receptor PAS1 which specifically interacts with toluene was chosen as a capture agent for SIS ellipsometric sensing. We constructed wild PAS1 and mutant PAS1 (F46A and F79Y) which are toluene binding-defective. Especially, we utilized an easily accessible capturing approach based on silica binding peptide (SBP) for direct immobilization of PAS1 on the SiO2 surfaces. After the immobilization of SBP-tagged PAS1 to the sensing layers, PAS1-based SIS sensor was evaluated for its ability to recognize toluene. As a result, a significant up-shift in Psi (Ψ) was clearly observed with a low limit of detection (LOD) of 0.1 μM, when treated with toluene on wild PAS1-surface, but not on mutant PAS1-sensing layers, indicating the selective interactions between PAS1 and toluene molecule. The PAS1-SIS sensor showed no changes in Psi (Ψ), if any, negligible, when exposed to benzene, phenol, xylene and 4-nitrophenol as negative controls, thereby demonstrating the specificity of interaction between PAS1 and toluene. Taken together, our results strongly indicate that PAS1-modified ellipsometry sensor can provide a high fidelity system for the accurate and selective detection of toluene.
Collapse
|
4
|
Song XY, Chen J, Shi YP. Different configurations of carbon nanotubes reinforced solid-phase microextraction techniques and their applications in the environmental analysis. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.11.006] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
5
|
TermehYousefi A, Tanaka H, Bagheri S. Enhancement of glucose oxide electron-transfer mechanism in glucose biosensor via optimum physical chemistry of functionalized carbon nanotubes. REV CHEM ENG 2017. [DOI: 10.1515/revce-2015-0051] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractNanostructures are a viable candidate for the construction of simple blood sugar monitoring devices. Electrochemical oxidation based on the immobilization of glucose oxidase (GOx) on carbon nanostructures has paved the way for a modern approach to the determination of glucose levels in blood. Carbon nanotubes (CNTs) exhibit excellent electrical properties, resulting in increased interest in glucose biosensors based on CNTs. Its large surface area and optimum aspect ratio increase the total amount of immobilized biomaterials onto its surface. In this contribution, recent advances in the development of reliable methods to improve the electron-transfer mechanism of GOx in CNT-based glucose biosensors are highlighted. Moreover, mass production and growth mechanism of purified CNTs by chemical vapor deposition were discussed by emphasizing its growth-control aspects.
Collapse
|
6
|
Ha W, Song XY, Chen J, Shi YP. A physical entrapment method for the preparation of carbon nanotube reinforced macroporous adsorption resin with enhanced selective extraction performance. NANOSCALE 2015; 7:18619-18627. [PMID: 26490261 DOI: 10.1039/c5nr05454k] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In this paper, we demonstrate a novel carbon nanotube (CNT) reinforced macroporous adsorption resin (MAR) for the first time. The CNTs were dispersed in water via sonication, and then in situ physically entrapped in the pores of MAR by capillary forces and sonication. The resulting CNT reinforced MAR (CNT-MAR) was proved by transmission electron microscopy (TEM) and confocal laser scanning microscopy (CLSM), and subsequently applied to extract a mixture of 8 types, 14 natural products. For comparison, the extraction efficiency of original MAR without CNTs was also evaluated. After extraction, the supernatants were detected via high-performance liquid chromatography (HPLC). The results indicated that the introduction of carbon nanotubes (CNTs) into the pores of MAR can significantly improve the adsorptive selectivity of MAR for natural products. The original MAR without CNTs has almost the same adsorption capacity for selectively extracting 3 types of natural products (phenols, alkaloids and anthraquinones). However, the CNT-MAR only could selectively extract anthraquinones and the adsorption capacity for three anthraquinone natural products is 1.46-1.83 times higher than that of unmodified MAR. In order to achieve the highest extraction efficiency of CNT-MAR for anthraquinone natural products, the main extraction parameters such as the extraction time and the pH value were also optimized. The CNT-MAR demonstrated an excellent ability to extract anthraquinone natural products with high selectivity and adsorption capacity. Due to its low cost, easy preparation and use, and operational characteristics, it shows great potential for selective extraction of natural products.
Collapse
Affiliation(s)
- Wei Ha
- Key Laboratory of Chemistry of Northwestern Plant Resources of CAS and Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, P. R. China.
| | | | | | | |
Collapse
|
7
|
Mahmoud AM, Abd El-Rahman MK, Elghobashy MR, Rezk MR. Carbon nanotubes versus polyaniline nanoparticles; which transducer offers more opportunities for designing a stable solid contact ion-selective electrode. J Electroanal Chem (Lausanne) 2015. [DOI: 10.1016/j.jelechem.2015.07.045] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
8
|
SONG Y, MA L. A Solid-contact Pb 2+-selective Electrode with Carbon Nanotubes by Electrodeposition as Ion-to-electron Transducer. ELECTROCHEMISTRY 2015. [DOI: 10.5796/electrochemistry.83.402] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Yuehai SONG
- School of Environmental and Materials Engineering, Yantai University
| | - Lijie MA
- School of Environmental and Materials Engineering, Yantai University
| |
Collapse
|
9
|
|
10
|
Washe AP, Lozano P, Bejarano D, Katakis I. Eletrochemically actuated stop-go valves for capillary force-operated diagnostic microsystems. Chemphyschem 2013; 14:2164-73. [PMID: 23592401 DOI: 10.1002/cphc.201300042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2013] [Indexed: 11/10/2022]
Abstract
Lateral-flow immunosensing devices continue to be the most successful commercial realization of analytical microdevices. They owe their success to their simplicity, which significantly depends on the capillary-driven flow and versatile technological platform that lends itself to fast and low-cost product development. To compete with such a convenient product, microsystems can benefit from simple-to-operate fluid manipulation. We show that the capillary-driven flow in microchannels can be manipulated with electrochemically activated valves with no moving parts. These valves consist of screen-printed electrode pairs that are transversal to the flow. One of the electrodes is solvent-etched to produce a superhydrophobic surface that provides passive stopping and facilitates low-voltage (~1 V) actuation of the flow via electrowetting. The operation of such valves in the stop-go mode, with a response time between 2 and 45 sec depending on the type and concentration of salt, is demonstrated. Mechanistic investigations indicated that the response depends on at least three phenomena that contribute to electrocapillarity: the electrochemical double-layer capacitance, specific counterion adsorption, and possible electrohydrodynamic effects.
Collapse
Affiliation(s)
- Alemayehu P Washe
- Bioengineering and Bioelectrochemistry Group, Department of Chemical Engineering, Universitat Rovira i Virgili, Avinguda Països Catalans, 26, 43007, Tarragona, Spain
| | | | | | | |
Collapse
|
11
|
Guinovart T, Parrilla M, Crespo GA, Rius FX, Andrade FJ. Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes. Analyst 2013; 138:5208-15. [PMID: 23775189 DOI: 10.1039/c3an00710c] [Citation(s) in RCA: 95] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A simple and generalized approach to build electrochemical sensors for wearable devices is presented. Commercial cotton yarns are first turned into electrical conductors through a simple dyeing process using a carbon nanotube ink. These conductive yarns are then partially coated with a suitable polymeric membrane to build ion-selective electrodes. Potentiometric measurements using these yarn-potentiometric sensors are demonstrated. Examples of yarns that can sense pH, K(+) and NH4(+) are presented. In all cases, these sensing yarns show limits of detection and linear ranges that are similar to those obtained with lab-made solid-state ion-selective electrodes. Through the immobilization of these sensors in a band-aid, it is shown that this approach could be easily implemented in a wearable device. Factors affecting the performance of the sensors and future potential applications are discussed.
Collapse
Affiliation(s)
- Tomàs Guinovart
- Departamento de Química Orgánica y Química Analítica, Universitat Rovira i Virgili, Carrer Marcel-li Domingo s/n, 43007 Tarragona, Spain
| | | | | | | | | |
Collapse
|
12
|
Soleimani M, Afshar MG, Shafaat A, Crespo GA. High-Selective Tramadol Sensor Based on Modified Molecularly Imprinted PolymerCarbon Paste Electrode with Multiwalled Carbon Nanotubes. ELECTROANAL 2013. [DOI: 10.1002/elan.201200601] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
13
|
Washe AP, Lozano-Sánchez P, Bejarano-Nosas D, Katakis I. Facile and versatile approaches to enhancing electrochemical performance of screen printed electrodes. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2012.12.110] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
14
|
Woźnica E, Wójcik MM, Mieczkowski J, Maksymiuk K, Michalska A. Dithizone Modified Gold Nanoparticles Films as Solid Contact for Cu2+Ion-Selective Electrodes. ELECTROANAL 2012. [DOI: 10.1002/elan.201200385] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
15
|
|
16
|
Woźnica E, Wójcik MM, Wojciechowski M, Mieczkowski J, Bulska E, Maksymiuk K, Michalska A. Dithizone Modified Gold Nanoparticles Films for Potentiometric Sensing. Anal Chem 2012; 84:4437-42. [DOI: 10.1021/ac300155f] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Emilia Woźnica
- Faculty of
Chemistry, University of Warsaw, Pasteura
1, 02-093 Warsaw, Poland
| | - Michał M. Wójcik
- Faculty of
Chemistry, University of Warsaw, Pasteura
1, 02-093 Warsaw, Poland
| | | | - Józef Mieczkowski
- Faculty of
Chemistry, University of Warsaw, Pasteura
1, 02-093 Warsaw, Poland
| | - Ewa Bulska
- Faculty of
Chemistry, University of Warsaw, Pasteura
1, 02-093 Warsaw, Poland
| | - Krzysztof Maksymiuk
- Faculty of
Chemistry, University of Warsaw, Pasteura
1, 02-093 Warsaw, Poland
| | - Agata Michalska
- Faculty of
Chemistry, University of Warsaw, Pasteura
1, 02-093 Warsaw, Poland
| |
Collapse
|
17
|
Ping J, Wang Y, Ying Y, Wu J. Application of Electrochemically Reduced Graphene Oxide on Screen-Printed Ion-Selective Electrode. Anal Chem 2012; 84:3473-9. [DOI: 10.1021/ac203480z] [Citation(s) in RCA: 135] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Jianfeng Ping
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| | - Yixian Wang
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| | - Yibin Ying
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| | - Jian Wu
- College of Biosystems Engineering and Food
Science, Zhejiang University, Hangzhou
310058, PR China
| |
Collapse
|
18
|
Affiliation(s)
- Danielle W. Kimmel
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| | - Gabriel LeBlanc
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| | - Mika E. Meschievitz
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| | - David E. Cliffel
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, VU Station B 351822, Nashville, TN 37235-1822
| |
Collapse
|
19
|
Jaworska E, Lewandowski W, Mieczkowski J, Maksymiuk K, Michalska A. Non-covalently functionalized graphene for the potentiometric sensing of zinc ions. Analyst 2012; 137:1895-8. [DOI: 10.1039/c2an16016a] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
20
|
Gold nanoparticles solid contact for ion-selective electrodes of highly stable potential readings. Talanta 2011; 85:1986-9. [DOI: 10.1016/j.talanta.2011.07.049] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2011] [Revised: 07/07/2011] [Accepted: 07/09/2011] [Indexed: 11/17/2022]
|