1
|
Hayashi A, Hemmi R, Saito Y, Utoh R, Taniguchi T, Yamada M. High-Density Microporous Drainage-Integrating Sheath Flow Generator for Streamlining Microfluidic Cell Sorting Systems. Anal Chem 2024; 96:6764-6773. [PMID: 38619911 DOI: 10.1021/acs.analchem.4c00485] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.
Collapse
Affiliation(s)
- Ayumi Hayashi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Runa Hemmi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Yuhei Saito
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Rie Utoh
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Tatsuo Taniguchi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| | - Masumi Yamada
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan
| |
Collapse
|
2
|
Zhang X, Ma Y, Wang Y, Liang Z, Zhang X, Chen Y, Wang Q, Qin H, Wang J. Precision Phenotypic Profiling and Capture of Circulating Tumor Cells via a Vertical Laminar Flow-Stacked Microfluidic Chip. MICROMACHINES 2024; 15:542. [PMID: 38675353 PMCID: PMC11051858 DOI: 10.3390/mi15040542] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 04/03/2024] [Accepted: 04/05/2024] [Indexed: 04/28/2024]
Abstract
The heterogeneity of circulating tumor cells has a significant impact on the diagnosis, treatment, and monitoring of cancer. Research on the subtypes of circulating tumor cells can bring better treatment outcomes for cancer patients. Here, we proposed a microfluidic chip for the magnetic capture of subtypes of circulating tumor cells from the whole blood and phenotypic profiling by stacking laminar flow vertically. Circulating tumor cells were sorted and captured by the three-dimensional regulation of both magnetic fields in the vertical direction and flow fields in the lateral direction. Using EpCAM-magnetic beads, we achieved sorting and sectional capture of target cells in whole blood and analyzed the surface expression levels of the captured cells, confirming the functionality of the microfluidic chip in sorting and capturing subtypes of circulating tumor cells. This microfluidic chip can also aid in the subsequent subtype analysis of other rare cells.
Collapse
Affiliation(s)
- Xinping Zhang
- School of Mechanical-Electronic and Vehicle Engineering, Beijing University of Civil Engineering and Architecture, Beijing 102616, China
| | - Yuan Ma
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Yujiao Wang
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Zhenwei Liang
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Xuanhe Zhang
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Yiqing Chen
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| | - Qingyi Wang
- School of Mechanical-Electronic and Vehicle Engineering, Beijing University of Civil Engineering and Architecture, Beijing 102616, China
| | - Hua Qin
- School of Mechanical-Electronic and Vehicle Engineering, Beijing University of Civil Engineering and Architecture, Beijing 102616, China
| | - Jiadao Wang
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|
3
|
Kimijima J, Inagawa A, Uehara N. Incorporation of a Morphologically Controlled Ice Grain Boundary into a Microfluidic Device for Size-Selective Separation of Micro/Nanospheres. Anal Chem 2023; 95:14963-14971. [PMID: 37766381 DOI: 10.1021/acs.analchem.3c02330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
A frozen aqueous solution was integrated into a microfluidic device as a size-tunable separation field for the size-selective separation of micro/nanospheres. The width of the ice grain boundaries formed in frozen aqueous solutions could be altered by controlling the operating temperature. A freezing chamber was placed adjacent to the microfluidic channel. A sample-dispersing aqueous sucrose solution was injected into the chamber and frozen, allowing the freeze-concentrated solution (FCS) to run vertically to the microfluidic channel, where the eluting solution flows. The operating temperature can be used to control the physical interaction between the ice wall and micro/nanospheres, enabling size-selective migration. The eluted micro/nanospheres in the microchannel were passed through the eluting solution collected from the outlet. We achieved size-selective separation and collection of microspheres and nanospheres. We separated the exosomes and yeast cells to demonstrate their applicability in bioseparation. The present method is suitable not only for size-selective separation but also for evaluating the biological expression of extracellular vesicles under cryogenic conditions.
Collapse
Affiliation(s)
- Junya Kimijima
- Faculty of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi 321-8585, Japan
| | - Arinori Inagawa
- Faculty of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi 321-8585, Japan
| | - Nobuo Uehara
- Faculty of Engineering, Utsunomiya University, 7-1-2, Yoto, Utsunomiya, Tochigi 321-8585, Japan
| |
Collapse
|
4
|
Mahani MA, Karimvand AN, Naserifar N. Optimized hybrid dielectrophoretic microchip for separation of bioparticles. J Sep Sci 2023; 46:e2300257. [PMID: 37480169 DOI: 10.1002/jssc.202300257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2023] [Revised: 07/12/2023] [Accepted: 07/13/2023] [Indexed: 07/23/2023]
Abstract
Point-of-care diagnostics requires a smart separation of particles and/or cells. In this work, the multiorifice fluid fractionation as a passive method and dielectrophoresis-based actuator as an active tool are combined to offer a new device for size-based particle separation. The main objective of the combination of these two well-established techniques is to improve the performance of the multiorifice fluid fractionation by taking advantage of dielectrophoresis-based actuator for separating particles. Initially, by using numerical simulations, the effect of using dielectrophoresis-based actuator in multiorifice fluid fractionation on the separation of particles was investigated, and the size of the device was optimized by 25% compared to a device without dielectrophoresis-based actuator. Also, adding dielectrophoresis-based actuator to multiorifice fluid fractionation can extend the range of flow rates needed for separation. In the absence of dielectrophoresis-based actuator, the separation took place only when the flow rate is 100 μL/min, in the presence of dielectrophoresis-based actuator (20 Vp-p), the separation happened in flow rates ranging from 70 to 120 μL/min.
Collapse
Affiliation(s)
- Moheb Amir Mahani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | | | - Naser Naserifar
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
5
|
Ma X, Guo G, Wu X, Wu Q, Liu F, Zhang H, Shi N, Guan Y. Advances in Integration, Wearable Applications, and Artificial Intelligence of Biomedical Microfluidics Systems. MICROMACHINES 2023; 14:mi14050972. [PMID: 37241596 DOI: 10.3390/mi14050972] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 04/20/2023] [Accepted: 04/25/2023] [Indexed: 05/28/2023]
Abstract
Microfluidics attracts much attention due to its multiple advantages such as high throughput, rapid analysis, low sample volume, and high sensitivity. Microfluidics has profoundly influenced many fields including chemistry, biology, medicine, information technology, and other disciplines. However, some stumbling stones (miniaturization, integration, and intelligence) strain the development of industrialization and commercialization of microchips. The miniaturization of microfluidics means fewer samples and reagents, shorter times to results, and less footprint space consumption, enabling a high throughput and parallelism of sample analysis. Additionally, micro-size channels tend to produce laminar flow, which probably permits some creative applications that are not accessible to traditional fluid-processing platforms. The reasonable integration of biomedical/physical biosensors, semiconductor microelectronics, communications, and other cutting-edge technologies should greatly expand the applications of current microfluidic devices and help develop the next generation of lab-on-a-chip (LOC). At the same time, the evolution of artificial intelligence also gives another strong impetus to the rapid development of microfluidics. Biomedical applications based on microfluidics normally bring a large amount of complex data, so it is a big challenge for researchers and technicians to analyze those huge and complicated data accurately and quickly. To address this problem, machine learning is viewed as an indispensable and powerful tool in processing the data collected from micro-devices. In this review, we mainly focus on discussing the integration, miniaturization, portability, and intelligence of microfluidics technology.
Collapse
Affiliation(s)
- Xingfeng Ma
- School of Communication and Information Engineering, Shanghai University, Shanghai 200000, China
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
| | - Gang Guo
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
| | - Xuanye Wu
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
| | - Qiang Wu
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| | - Fangfang Liu
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
| | - Hua Zhang
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| | - Nan Shi
- Shanghai Industrial μTechnology Research Institute, Shanghai 200000, China
- Institute of Translational Medicine, Shanghai University, Shanghai 200000, China
| | - Yimin Guan
- Department of Microelectronics, Shanghai University, Shanghai 200000, China
- Shanghai Aure Technology Limited Company, Shanghai 200000, China
| |
Collapse
|
6
|
Piao J, Liu L, Cai L, Ri HC, Jin X, Sun H, Piao X, Shang HB, Jin X, Pu Q, Cai Y, Yao Z, Nardiello D, Quinto M, Li D. High-Resolution Micro-object Separation by Rotating Magnetic Chromatography. Anal Chem 2022; 94:11500-11507. [PMID: 35943850 DOI: 10.1021/acs.analchem.2c01385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The development of new technologies for the separation, selection, and isolation of microparticles such as rare target cells, circulating tumor cells, cancer stem cells, and immune cells has become increasingly important in the last few years. Microparticle separation technologies are usually applied to the analysis of disease-associated cells, but these procedures often face a cell separation problem that is often insufficient for single specific cell analyses. To overcome these limitations, a highly accurate size-based microparticle separation technique, herein called "rotating magnetic chromatography", is proposed in this work. Magnetic nanoparticles, placed in a microfluidic separation channel, are forced to move in well-defined trajectories by an external magnetic field, colliding with microparticles that are in this way separated on the basis of their dimensions with high accuracy and reproducibility. The method was optimized by using fluorescein isothiocyanate-modified polystyrene particles (chosen as a reference standard) and then applied to the analysis of cancer cells like Hep-3B and SK-Hep-1, allowing their fast and high-resolution chromatographic separation as a function of their dimensions. Due to its unmatched sub-micrometer cell separation capabilities, RMC can be considered a break-through technique that can unlock new perspectives in different scientific fields, that is, in medical oncology.
Collapse
Affiliation(s)
- Jishou Piao
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Lu Liu
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Long Cai
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Hyok Chol Ri
- College of Pharmacy, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Xiangzi Jin
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Huaze Sun
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Xiangfan Piao
- Engineering College Department of Electronics, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Hai-Bo Shang
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Xuejun Jin
- College of Pharmacy, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| | - Qiaosheng Pu
- State Key Laboratory of Applied Organic Chemistry, College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, China
| | - Yong Cai
- College of Life Science, Jilin University, Changchun City, Jilin province 130012, China
| | - Zhongping Yao
- State Key Laboratory of Chirosciences, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR 999077, China
| | - Donatella Nardiello
- DAFNE─Department of Agriculture, Food, Natural resources and Engineering, University of Foggia, Via Napoli 25, I-71122 Foggia, Italy
| | - Maurizio Quinto
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China.,DAFNE─Department of Agriculture, Food, Natural resources and Engineering, University of Foggia, Via Napoli 25, I-71122 Foggia, Italy
| | - Donghao Li
- Department of Chemistry, Yanbian University, Park Road 977, Yanji City, Jilin Province 133002, China
| |
Collapse
|
7
|
Agarwal D, Thakur AD, Thakur A. Magnetic microbot-based micromanipulation of surrogate biological objects in fluidic channels. JOURNAL OF MICRO-BIO ROBOTICS 2022. [DOI: 10.1007/s12213-022-00151-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
8
|
Li M, Li D, Song Y, Li D. Tunable particle/cell separation across aqueous two-phase system interface by electric pulse in microfluidics. J Colloid Interface Sci 2022; 612:23-34. [PMID: 34974255 DOI: 10.1016/j.jcis.2021.12.140] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/10/2021] [Accepted: 12/21/2021] [Indexed: 01/16/2023]
Abstract
HYPOTHESIS Separations of particles and cells are indispensable in many microfluidic systems and have numerous applications in chemistry and biomedicine. The interface of aqueous two-phase system (ATPS) can act as a liquid filter. Under electric field stimuli, the selective transfer of targets across the liquid-liquid interface are expected for particles and cells separation. EXPERIMENTS The separations of particles and cells based on ATPS electrophoresis in a microfluidic chip were investigated. A systematical study of the mechanism of ATPS electrophoresis was performed first by employing polystyrene (PS) particles. Subsequently, the separations of particles and microalgae cells were demonstrated. FINDINGS The electrophoretic transfer of particles across the interface of ATPS is determined by multi-parameters, including the strength of electric pulse, particle size, zeta potential, and hydrophobicity of the particle. The continuous separations of particles/cells can be achieved through the controllable transfer of target particles/cells across the interface under electric pulses in a microfluidic chip. By simply turning the magnitude of the applied electric pulse, the technique is suitable for different purposes, for example, the separations of particles and cells, purification of cells, and viability identification of cells. This tunable separation approach opens opportunities in multidimensional particle and cell sorting for the fields of seed selection of microorganisms, environmental assessment, and biomedical research.
Collapse
Affiliation(s)
- Mengqi Li
- Department of Marine Engineering, Dalian Maritime University, Dalian 116026, China
| | - Deyu Li
- Department of Marine Engineering, Dalian Maritime University, Dalian 116026, China
| | - Yongxin Song
- Department of Marine Engineering, Dalian Maritime University, Dalian 116026, China
| | - Dongqing Li
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1.
| |
Collapse
|
9
|
Multi-Modal Microfluidics (M3) for Sample Preparation of Liquid Biopsy: Bridging the Gap between Proof-of-Concept Demonstrations and Practical Applications. MICROMACHINES 2022; 13:mi13020209. [PMID: 35208333 PMCID: PMC8874502 DOI: 10.3390/mi13020209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 01/23/2022] [Accepted: 01/26/2022] [Indexed: 02/01/2023]
Abstract
Liquid biopsy, the technique used to shed light on diseases via liquid samples, has displayed various advantages, including minimal invasiveness, low risk, and ease of multiple sampling for dynamic monitoring, and has drawn extensive attention from multidisciplinary fields in the past decade. With the rapid development of microfluidics, it has been possible to manipulate targets of interest including cells, microorganisms, and exosomes at a single number level, which dramatically promotes the characterization and analysis of disease-related markers, and thus improves the capability of liquid biopsy. However, when lab-ready techniques transfer into hospital-applicable tools, they still face a big challenge in processing raw clinical specimens, which are usually of a large volume and consist of rare targets drowned in complex backgrounds. Efforts toward the sample preparation of clinical specimens (i.e., recovering/concentrating the rare targets among complex backgrounds from large-volume liquids) are required to bridge the gap between the proof-of-concept demonstrations and practical applications. The throughput, sensitivity, and purity (TSP performance criteria) in sample preparation, i.e., the volume speed in processing liquid samples and the efficiencies of recovering rare targets and depleting the backgrounds, are three key factors requiring careful consideration when implementing microfluidic-based liquid biopsy for clinical practices. Platforms based on a single microfluidic module (single-modal microfluidics) can hardly fulfill all the aforementioned TSP performance criteria in clinical practices, which puts forward an urgent need to combine/couple multiple microfluidic modules into one working system (i.e., multi-modal microfluidics, M3) to realize practically applicable techniques for the sample preparation of liquid biopsy. This perspective briefly summarizes the typical microfluidic-based liquid biopsy techniques and discusses potential strategies to develop M3 systems for clinical practices of liquid biopsy from the aspect of sample preparation.
Collapse
|
10
|
[Research progress in the application of external field separation technology and microfluidic technology in the separation of micro/nanoscales]. Se Pu 2021; 39:1157-1170. [PMID: 34677011 PMCID: PMC9404220 DOI: 10.3724/sp.j.1123.2020.12032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The micro/nanoscales concerns interactions of entities with sizes in the range of 0.1-100 μm, such as biological cells, proteins, and particles. The separation of micro/nanoscales has been of immense significance for drug development, early-stage cancer detection, and customized precision therapy. For example, in recent years, rapid advances in the field of cell therapy have necessitated the development of simple and effective cell separation techniques. The isolation technique allows the collection of the required stem cells from complex samples. With the development of materials science and precision medicine, the separation of particles is also critical. The key physicochemical properties of micro/nanoscales are highly dependent on their specific size, shape, functional group, and mobility (based on the charged characteristics), which control their performance in the separation system. The current demand has made the simultaneous innovation of a separation system and an on-line detection platform imperative. Accordingly, various analytical methods involving the use of external forces, such as the flow field, magnetic field, electric field, and acoustic field, have been used for micro/nanoscales separation. Based on the physical and chemical parameters of the separation materials, these analytical methods can select different external force fields for micro/nanoscales separation, enabling real-time, accurate, efficient, and selective separation. However, at present, most of the applied field separation technologies require complex equipment and a large sample amount. This makes it crucial to miniaturize and integrate separation technologies for low-cost, rapid, and accurate micro/nanoscales separation. Microfluidic technology is a representative micro/nanoscales separation technology. It requires only a small volume of liquid, making it cost-effective; its high throughput enables continuous separation and analysis; its fast response in a microchip can allow many reactions; and finally, the miniaturization of the device allows the coupling of multiple detectors with the microchip. With the continuous growth and progress of microfluidic technology, some microfluidic platforms are now able to achieve the non-destructive separation of cells. They also enable on-line detection, offer high separation efficiency, and allow rapid separation for different biological samples. This review primarily summarizes recent advances in microfluidic chips based on flow field, electric field, magnetic field, acoustic field, and field separation technologies to improve the micro/nanoscales separation efficiency. This review also discusses the various external force fields of micro/nanoscales, such as a microparticle, single cell separation of substances classified introduction, and summarizes the advantages and disadvantages of their application and development. Finally, the prospect of the combined application of external field separation technology and microfluidic technology in the early screening of cancer cells and for precise micro/nanoscales separation is discussed, and the advantages and potential applications of the combined technology are proposed.
Collapse
|
11
|
Liu Y, Zhao W, Cheng R, Puig A, Hodgson J, Egan M, Cooper Pope CN, Nikolinakos PG, Mao L. Label-free inertial-ferrohydrodynamic cell separation with high throughput and resolution. LAB ON A CHIP 2021; 21:2738-2750. [PMID: 34018527 DOI: 10.1039/d1lc00282a] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Rapid and label-free separation of target cells from biological samples provided unique opportunity for disease diagnostics and treatment. However, even with advanced technologies for cell separation, the limited throughput, high cost and low separation resolution still prevented their utility in separating cells with well-defined physical features from a large volume of biological samples. Here we described an ultrahigh-throughput microfluidic technology, termed as inertial-ferrohydrodynamic cell separation (inertial-FCS), that rapidly sorted through over 60 milliliters of samples at a throughput of 100 000 cells per second in a label-free manner, differentiating the cells based on their physical diameter difference with ∼1-2 μm separation resolution. Through the integration of inertial focusing and ferrohydrodynamic separation, we demonstrated that the resulting inertial-FCS devices could separate viable and expandable circulating tumor cells from cancer patients' blood with a high recovery rate and high purity. We also showed that the devices could enrich lymphocytes directly from white blood cells based on their physical morphology without any labeling steps. This label-free method could address the needs of high throughput and high resolution cell separation in circulating tumor cell research and adoptive cell transfer immunotherapy.
Collapse
Affiliation(s)
- Yang Liu
- Department of Chemistry, The University of Georgia, Athens, Georgia, USA
| | - Wujun Zhao
- FCS Technology LLC, Athens, Georgia, USA
| | - Rui Cheng
- School of Electrical and Computer Engineering, College of Engineering, The University of Georgia, Athens, Georgia, USA.
| | - Alicia Puig
- Department of Microbiology, Texas State University, San Marcos, Texas, USA
| | - Jamie Hodgson
- University Cancer & Blood Center, LLC, Athens, Georgia, USA
| | - Mary Egan
- University Cancer & Blood Center, LLC, Athens, Georgia, USA
| | | | | | - Leidong Mao
- School of Electrical and Computer Engineering, College of Engineering, The University of Georgia, Athens, Georgia, USA.
| |
Collapse
|
12
|
Tang W, Zhu S, Jiang D, Zhu L, Yang J, Xiang N. Channel innovations for inertial microfluidics. LAB ON A CHIP 2020; 20:3485-3502. [PMID: 32910129 DOI: 10.1039/d0lc00714e] [Citation(s) in RCA: 76] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Inertial microfluidics has gained significant attention since first being proposed in 2007 owing to the advantages of simplicity, high throughput, precise manipulation, and freedom from an external field. Superior performance in particle focusing, filtering, concentrating, and separating has been demonstrated. As a passive technology, inertial microfluidics technology relies on the unconventional use of fluid inertia in an intermediate Reynolds number range to induce inertial migration and secondary flow, which depend directly on the channel structure, leading to particle migration to the lateral equilibrium position or trapping in a specific cavity. With the advances in micromachining technology, many channel structures have been designed and fabricated in the past decade to explore the fundamentals and applications of inertial microfluidics. However, the channel innovations for inertial microfluidics have not been discussed comprehensively. In this review, the inertial particle manipulations and underlying physics in conventional channels, including straight, spiral, sinusoidal, and expansion-contraction channels, are briefly described. Then, recent innovations in channel structure for inertial microfluidics, especially channel pattern modification and unconventional cross-sectional shape, are reviewed. Finally, the prospects for future channel innovations in inertial microfluidic chips are also discussed. The purpose of this review is to provide guidance for the continued study of innovative channel designs to improve further the accuracy and throughput of inertial microfluidics.
Collapse
Affiliation(s)
- Wenlai Tang
- School of Electrical and Automation Engineering, Jiangsu Key Laboratory of 3D Printing Equipment and Manufacturing, Nanjing Normal University, Nanjing, 210023, China.
| | | | | | | | | | | |
Collapse
|
13
|
Jung T, Jung Y, Ahn J, Yang S. Continuous, rapid concentration of foodborne bacteria (Staphylococcus aureus, Salmonella typhimurium, and Listeria monocytogenes) using magnetophoresis-based microfluidic device. Food Control 2020. [DOI: 10.1016/j.foodcont.2020.107229] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
14
|
Nasiri R, Shamloo A, Ahadian S, Amirifar L, Akbari J, Goudie MJ, Lee K, Ashammakhi N, Dokmeci MR, Di Carlo D, Khademhosseini A. Microfluidic-Based Approaches in Targeted Cell/Particle Separation Based on Physical Properties: Fundamentals and Applications. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e2000171. [PMID: 32529791 DOI: 10.1002/smll.202000171] [Citation(s) in RCA: 89] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 03/15/2020] [Indexed: 06/11/2023]
Abstract
Cell separation is a key step in many biomedical research areas including biotechnology, cancer research, regenerative medicine, and drug discovery. While conventional cell sorting approaches have led to high-efficiency sorting by exploiting the cell's specific properties, microfluidics has shown great promise in cell separation by exploiting different physical principles and using different properties of the cells. In particular, label-free cell separation techniques are highly recommended to minimize cell damage and avoid costly and labor-intensive steps of labeling molecular signatures of cells. In general, microfluidic-based cell sorting approaches can separate cells using "intrinsic" (e.g., fluid dynamic forces) versus "extrinsic" external forces (e.g., magnetic, electric field, etc.) and by using different properties of cells including size, density, deformability, shape, as well as electrical, magnetic, and compressibility/acoustic properties to select target cells from a heterogeneous cell population. In this work, principles and applications of the most commonly used label-free microfluidic-based cell separation methods are described. In particular, applications of microfluidic methods for the separation of circulating tumor cells, blood cells, immune cells, stem cells, and other biological cells are summarized. Computational approaches complementing such microfluidic methods are also explained. Finally, challenges and perspectives to further develop microfluidic-based cell separation methods are discussed.
Collapse
Affiliation(s)
- Rohollah Nasiri
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Amir Shamloo
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Samad Ahadian
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
| | - Leyla Amirifar
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Javad Akbari
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, 11365-11155, Iran
| | - Marcus J Goudie
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - KangJu Lee
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Nureddin Ashammakhi
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Mehmet R Dokmeci
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| | - Ali Khademhosseini
- Center for Minimally Invasive Therapeutics (C-MIT), University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Terasaki Institute for Biomedical Innovation (TIBI), Los Angeles, CA, 90024, USA
- Department of Radiological Sciences, University of California, Los Angeles, Los Angeles, CA, 90095, USA
- Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA
| |
Collapse
|
15
|
A Review of Secondary Flow in Inertial Microfluidics. MICROMACHINES 2020; 11:mi11050461. [PMID: 32354106 PMCID: PMC7280964 DOI: 10.3390/mi11050461] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/23/2020] [Accepted: 04/27/2020] [Indexed: 11/17/2022]
Abstract
Inertial microfluidic technology, which can manipulate the target particle entirely relying on the microchannel characteristic geometry and intrinsic hydrodynamic effect, has attracted great attention due to its fascinating advantages of high throughput, simplicity, high resolution and low cost. As a passive microfluidic technology, inertial microfluidics can precisely focus, separate, mix or trap target particles in a continuous and high-flow-speed manner without any extra external force field. Therefore, it is promising and has great potential for a wide range of industrial, biomedical and clinical applications. In the regime of inertial microfluidics, particle migration due to inertial effects forms multiple equilibrium positions in straight channels. However, this is not promising for particle detection and separation. Secondary flow, which is a relatively minor flow perpendicular to the primary flow, may reduce the number of equilibrium positions as well as modify the location of particles focusing within channel cross sections by applying an additional hydrodynamic drag. For secondary flow, the pattern and magnitude can be controlled by the well-designed channel structure, such as curvature or disturbance obstacle. The magnitude and form of generated secondary flow are greatly dependent on the disturbing microstructure. Therefore, many inventive and delicate applications of secondary flow in inertial microfluidics have been reported. In this review, we comprehensively summarize the usage of the secondary flow in inertial microfluidics.
Collapse
|
16
|
Sivaramakrishnan M, Kothandan R, Govindarajan DK, Meganathan Y, Kandaswamy K. Active microfluidic systems for cell sorting and separation. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2020. [DOI: 10.1016/j.cobme.2019.09.014] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
17
|
Mu T, Toyoda H, Kimura Y, Yamada M, Utoh R, Umeno D, Seki M. Laborless, Automated Microfluidic Tandem Cell Processor for Visualizing Intracellular Molecules of Mammalian Cells. Anal Chem 2020; 92:2580-2588. [PMID: 31822057 DOI: 10.1021/acs.analchem.9b04288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Visualization and quantification of intracellular molecules of mammalian cells are crucial steps in clinical diagnosis, drug development, and basic biological research. However, conventional methods rely mostly on labor-intensive, centrifugation-based manual operations for exchanging the cell carrier medium and have limited reproducibility and recovery efficiency. Here we present a microfluidic cell processor that can perform four-step exchange of carrier medium, simply by introducing a cell suspension and fluid reagents into the device. The reaction time period for each reaction step, including fixation, membrane permeabilization, and staining, was tunable in the range of 2 to 15 min by adjusting the volume of the reaction tube connecting the neighboring exchanger modules. We double-stained the cell nucleus and cytoskeleton (F-actin) using the presented device with an overall reaction period of ∼30 min, achieving a high recovery ratio and high staining efficiency. Additionally, intracellular cytokine (IL-2) was visualized for T cells to demonstrate the feasibility of the device as a pretreatment system for downstream flow-cytometric analysis. The presented approach would facilitate the development of laborless, automated microfluidic systems that integrate cell processing and analysis operations and would pave a new path to high-throughput biological experiments.
Collapse
Affiliation(s)
- Tinglin Mu
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| | - Hajime Toyoda
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| | - Yuki Kimura
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| | - Masumi Yamada
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| | - Rie Utoh
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| | - Daisuke Umeno
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| | - Minoru Seki
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering , Chiba University , 1-33 Yayoi-cho , Inage-ku , Chiba 263-8522 , Japan
| |
Collapse
|
18
|
Yanai T, Ouchi T, Yamada M, Seki M. Hydrodynamic Microparticle Separation Mechanism Using Three-Dimensional Flow Profiles in Dual-Depth and Asymmetric Lattice-Shaped Microchannel Networks. MICROMACHINES 2019; 10:mi10060425. [PMID: 31242547 PMCID: PMC6632020 DOI: 10.3390/mi10060425] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 06/20/2019] [Accepted: 06/21/2019] [Indexed: 01/09/2023]
Abstract
We herein propose a new hydrodynamic mechanism of particle separation using dual-depth, lattice-patterned asymmetric microchannel networks. This mechanism utilizes three-dimensional (3D) laminar flow profiles formed at intersections of lattice channels. Large particles, primarily flowing near the bottom surface, frequently enter the shallower channels (separation channels), whereas smaller particles flowing near the microchannel ceiling primarily flow along the deeper channels (main channels). Consequently, size-based continuous particle separation was achieved in the lateral direction in the lattice area. We confirmed that the depth of the main channel was a critical factor dominating the particle separation efficiencies, and the combination of 15-μm-deep separation channels and 40-μm-deep main channels demonstrated the good separation ability for 3–10-μm particles. We prepared several types of microchannels and successfully tuned the particle separation size. Furthermore, the input position of the particle suspension was controlled by adjusting the input flow rates and/or using a Y-shaped inlet connector that resulted in a significant improvement in the separation precision. The presented concept is a good example of a new type of microfluidic particle separation mechanism using 3D flows and may potentially be applicable to the sorting of various types of micrometer-sized objects, including living cells and synthetic microparticles.
Collapse
Affiliation(s)
- Takuma Yanai
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | - Takatomo Ouchi
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | - Masumi Yamada
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | - Minoru Seki
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| |
Collapse
|
19
|
Rapid and Safe Isolation of Human Peripheral Blood B and T Lymphocytes through Spiral Microfluidic Channels. Sci Rep 2019; 9:8145. [PMID: 31148602 PMCID: PMC6544655 DOI: 10.1038/s41598-019-44677-3] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 05/21/2019] [Indexed: 12/21/2022] Open
Abstract
Peripheral blood lymphocytes (PBLs) are mature lymphocytes that circulate in the blood rather than being localized to organs. A reliable label-free collection approach that can viably and appropriately isolate PBLs to establish in vitro culture systems is crucial for basic research and clinical requirements. However, isolation of PBLs from whole blood is difficult, and so the development of a rapid and safe method to perform this task is required. Microfluidic technology offers opportunities that challenge the performance of macroscale methods. In this study, we proposed a simple spiral microfluidic chip for efficient and high-throughput isolation of lymphocytes from a sample with prelysed RBCs. This spiral microfluidic platform does not rely on antibodies or biological markers for labeling cells of interest while isolating lymphocytes but rather enriches B and T lymphocytes through the different physical properties that are intrinsic to lymphocytes and other blood cells. The device was used to achieve high-throughput (~1.3 × 105 cells/min) separation of lymphocytes with high viability (>95%). Compared with previous approaches, our device provided rapid, label-free, high-throughput, and safe lymphocyte separation.
Collapse
|
20
|
Ozawa R, Iwadate H, Toyoda H, Yamada M, Seki M. A numbering-up strategy of hydrodynamic microfluidic filters for continuous-flow high-throughput cell sorting. LAB ON A CHIP 2019; 19:1828-1837. [PMID: 30998230 DOI: 10.1039/c9lc00053d] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Even though a number of microfluidic systems for particle/cell sorting have been proposed, facile and versatile platforms that provide sufficient sorting throughput and good operability are still under development. Here we present a simple but effective numbering-up strategy to dramatically increase the throughput of a continuous-flow particle/cell sorting scheme based on hydrodynamic filtration (HDF). A microfluidic channel equipped with multiple branches has been employed as a unit structure for size-based filtration, which realizes precise sorting without necessitating sheath flows. According to the concept of resistive circuit models, we designed and fabricated microdevices incorporating 64 or 128 closely assembled, multiplied units with a separation size of 5.0/7.0 μm. In proof-of-concept experiments, we successfully separated single micrometer-sized model particles and directly separated blood cells (erythrocytes and leukocytes) from blood samples. Additionally, we further increased the unit numbers by laminating multiple layers at a processing speed of up to 15 mL min-1. The presented numbering-up strategy would provide a valuable insight that is universally applicable to general microfluidic particle/cell sorters and may facilitate the actual use of microfluidic systems in biological studies and clinical diagnosis.
Collapse
Affiliation(s)
- Ryoken Ozawa
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | | | | | | | | |
Collapse
|
21
|
Lin S, Zhi X, Chen D, Xia F, Shen Y, Niu J, Huang S, Song J, Miao J, Cui D, Ding X. A flyover style microfluidic chip for highly purified magnetic cell separation. Biosens Bioelectron 2019; 129:175-181. [DOI: 10.1016/j.bios.2018.12.058] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 11/10/2018] [Accepted: 12/29/2018] [Indexed: 02/07/2023]
|
22
|
Zhou Y, Ma Z, Ai Y. Hybrid microfluidic sorting of rare cells based on high throughput inertial focusing and high accuracy acoustic manipulation. RSC Adv 2019; 9:31186-31195. [PMID: 35529382 PMCID: PMC9072550 DOI: 10.1039/c9ra01792e] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2019] [Accepted: 09/16/2019] [Indexed: 12/16/2022] Open
Abstract
The ability to isolate rare circulating tumor cells (CTCs) from blood samples is essential to perform liquid biopsy as a routine diagnostic and prognostic test. Both label-free and surface biomarker-based cell sorting technologies have been developed to address the demand in high-integrity isolation of rare CTCs for cancer research. Label-free cell sorting mainly relies on the size difference between CTCs and blood cells; thus, it lacks sufficient sorting specificity. Surface biomarker-based cell sorting is highly specific; however, it requires expensive, labor-intensive, and time-consuming labeling due to the use of multiple sets of surface biomarkers. Because of the complex nature and high heterogeneity of tumorigenesis, it is difficult to rely on a single sorting process for high-integrity rare cell isolation. In this study, for the first time, we present a hybrid microfluidic cell sorting method combining high throughput size-dependent inertial focusing for size-based pre-enrichment and high accuracy fluorescence activated acoustic sorting for single cell isolation. After one single hybrid sorting process, we have demonstrated at least 2500-fold purity enrichment of MCF-7 breast cancer cells spiked in diluted whole blood samples with cell viability maintained at 91 ± 1% (viability before sorting was 94 ± 2%). This developed hybrid microfluidic cell sorting technique provides a promising solution for rare cell isolation needed in a variety of biological research and clinical applications. The first example of integration of sized-based inertial sorting and surface biomarker-based acoustic sorting to achieve >2500-fold enrichment of rare cell populations.![]()
Collapse
Affiliation(s)
- Yinning Zhou
- Pillar of Engineering Product Development
- Singapore University of Technology and Design
- Singapore 487372
- Singapore
| | - Zhichao Ma
- Pillar of Engineering Product Development
- Singapore University of Technology and Design
- Singapore 487372
- Singapore
| | - Ye Ai
- Pillar of Engineering Product Development
- Singapore University of Technology and Design
- Singapore 487372
- Singapore
| |
Collapse
|
23
|
Dalili A, Samiei E, Hoorfar M. A review of sorting, separation and isolation of cells and microbeads for biomedical applications: microfluidic approaches. Analyst 2019; 144:87-113. [DOI: 10.1039/c8an01061g] [Citation(s) in RCA: 145] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
We have reviewed the microfluidic approaches for cell/particle isolation and sorting, and extensively explained the mechanism behind each method.
Collapse
Affiliation(s)
- Arash Dalili
- The University of British
- School of Engineering
- Kelowna
- Canada V1 V 1 V7
| | - Ehsan Samiei
- University of Victoria
- Department of Mechanical Engineering
- Victoria
- Canada
| | - Mina Hoorfar
- The University of British
- School of Engineering
- Kelowna
- Canada V1 V 1 V7
| |
Collapse
|
24
|
Yaman S, Anil-Inevi M, Ozcivici E, Tekin HC. Magnetic Force-Based Microfluidic Techniques for Cellular and Tissue Bioengineering. Front Bioeng Biotechnol 2018; 6:192. [PMID: 30619842 PMCID: PMC6305723 DOI: 10.3389/fbioe.2018.00192] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 11/23/2018] [Indexed: 01/21/2023] Open
Abstract
Live cell manipulation is an important biotechnological tool for cellular and tissue level bioengineering applications due to its capacity for guiding cells for separation, isolation, concentration, and patterning. Magnetic force-based cell manipulation methods offer several advantages, such as low adverse effects on cell viability and low interference with the cellular environment. Furthermore, magnetic-based operations can be readily combined with microfluidic principles by precisely allowing control over the spatiotemporal distribution of physical and chemical factors for cell manipulation. In this review, we present recent applications of magnetic force-based cell manipulation in cellular and tissue bioengineering with an emphasis on applications with microfluidic components. Following an introduction of the theoretical background of magnetic manipulation, components of magnetic force-based cell manipulation systems are described. Thereafter, different applications, including separation of certain cell fractions, enrichment of rare cells, and guidance of cells into specific macro- or micro-arrangements to mimic natural cell organization and function, are explained. Finally, we discuss the current challenges and limitations of magnetic cell manipulation technologies in microfluidic devices with an outlook on future developments in the field.
Collapse
|
25
|
Gong Y, Fan N, Yang X, Peng B, Jiang H. New advances in microfluidic flow cytometry. Electrophoresis 2018; 40:1212-1229. [PMID: 30242856 DOI: 10.1002/elps.201800298] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 09/07/2018] [Accepted: 09/15/2018] [Indexed: 01/22/2023]
Abstract
In recent years, researchers are paying the increasing attention to the development of portable microfluidic diagnostic devices including microfluidic flow cytometry for the point-of-care testing. Microfluidic flow cytometry, where microfluidics and flow cytometry work together to realize novel functionalities on the microchip, provides a powerful tool for measuring the multiple characteristics of biological samples. The development of a portable, low-cost, and compact flow cytometer can benefit the health care in underserved areas such as Africa or Asia. In this article, we review recent advancements of microfluidics including sample pumping, focusing and sorting, novel detection approaches, and data analysis in the field of flow cytometry. The challenge of microfluidic flow cytometry is also examined briefly.
Collapse
Affiliation(s)
- Yanli Gong
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Na Fan
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Xu Yang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| |
Collapse
|
26
|
Munaz A, Shiddiky MJA, Nguyen NT. Recent advances and current challenges in magnetophoresis based micro magnetofluidics. BIOMICROFLUIDICS 2018; 12:031501. [PMID: 29983837 PMCID: PMC6013300 DOI: 10.1063/1.5035388] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Accepted: 06/11/2018] [Indexed: 05/12/2023]
Abstract
The combination of magnetism and microscale fluid flow has opened up a new era for handling and manipulation of samples in microfluidics. In particular, magnetophoresis, the migration of particles in a magnetic field, is extremely attractive for microfluidic handling due to its contactless nature, independence of ionic concentration, and lack of induced heating. The present paper focuses on recent advances and current challenges of magnetophoresis and highlights the key parameters affecting the manipulation of particles by magnetophoresis. The magnetic field is discussed according to their relative motion to the sample as stationary and dynamic fields. The migration of particles is categorized as positive and negative magnetophoresis. The applications of magnetophoresis are discussed according to the basic manipulation tasks such as mixing, separation, and trapping of particles or cells. Finally, the paper highlights the limitations of current approaches and provides the future perspective for this research area.
Collapse
Affiliation(s)
- Ahmed Munaz
- Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia
| | | | - Nam-Trung Nguyen
- Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia
| |
Collapse
|
27
|
Wu C, Chen R, Liu Y, Yu Z, Jiang Y, Cheng X. A planar dielectrophoresis-based chip for high-throughput cell pairing. LAB ON A CHIP 2017; 17:4008-4014. [PMID: 29115319 DOI: 10.1039/c7lc01082f] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
This paper reports the design and fabrication of a planar chip for high-throughput cell trapping and pairing (more than 2400 single cell-cell pairs in a microwell array) in a 1 × 1.5 cm area by positive dielectrophoresis (p-DEP) within only several minutes. The p-DEP was generated by applying an alternating current signal on a novel two-pair interdigitated array (TPIDA) electrode. The TPIDA electrode not only enabled the planar chip to be incorporated with a most often used PDMS microfluidic channel, but also contributed to a high single cell-cell pairing efficiency up to 74.2% by decreasing the induced electric field during consecutive p-DEP trapping of two cell types. Furthermore, the paired cells in each microwell could be "pushed" together into a microbaffle by a liquid flow through a capillary-sized channel, resulting in single cell-cell contact. More importantly, the planar chip could be used repeatedly by a simple water cleaning process. The planar chip offers an effective way for high-throughput single cell-cell pairing, which could provide a facile platform for cell communication and a precise cell pairing step in cell fusion.
Collapse
Affiliation(s)
- ChunHui Wu
- Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, People's Republic of China.
| | | | | | | | | | | |
Collapse
|
28
|
Chiu DT, deMello AJ, Di Carlo D, Doyle PS, Hansen C, Maceiczyk RM, Wootton RC. Small but Perfectly Formed? Successes, Challenges, and Opportunities for Microfluidics in the Chemical and Biological Sciences. Chem 2017. [DOI: 10.1016/j.chempr.2017.01.009] [Citation(s) in RCA: 212] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
29
|
Yamada M, Seko W, Yanai T, Ninomiya K, Seki M. Slanted, asymmetric microfluidic lattices as size-selective sieves for continuous particle/cell sorting. LAB ON A CHIP 2017; 17:304-314. [PMID: 27975084 DOI: 10.1039/c6lc01237j] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Hydrodynamic microfluidic platforms have been proven to be useful and versatile for precisely sorting particles/cells based on their physicochemical properties. In this study, we demonstrate that a simple lattice-shaped microfluidic pattern can work as a virtual sieve for size-dependent continuous particle sorting. The lattice is composed of two types of microchannels ("main channels" and "separation channels"). These channels cross each other in a perpendicular fashion, and are slanted against the macroscopic flow direction. The difference in the densities of these channels generates an asymmetric flow distribution at each intersection. Smaller particles flow along the streamline, whereas larger particles are filtered and gradually separated from the stream, resulting in continuous particle sorting. We successfully sorted microparticles based on size with high accuracy, and clearly showed that geometric parameters, including the channel density and the slant angle, critically affect the sorting behaviors of particles. Leukocyte sorting and monocyte purification directly from diluted blood samples have been demonstrated as biomedical applications. The presented system for particle/cell sorting would become a simple but versatile unit operation in microfluidic apparatus for chemical/biological experiments and manipulations.
Collapse
Affiliation(s)
- Masumi Yamada
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | - Wataru Seko
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | - Takuma Yanai
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| | - Kasumi Ninomiya
- Asahi Kasei Corp, 2-1 Samejima, Fuji-shi, Shizuoka 416-8501, Japan
| | - Minoru Seki
- Department of Applied Chemistry and Biotechnology, Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan.
| |
Collapse
|
30
|
Yousuff CM, Ho ETW, Hussain K. I, Hamid NHB. Microfluidic Platform for Cell Isolation and Manipulation Based on Cell Properties. MICROMACHINES 2017. [PMCID: PMC6189901 DOI: 10.3390/mi8010015] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Caffiyar Mohamed Yousuff
- Correspondence: (C.M.Y.); (E.T.W.H.); (N.H.B.H.); Tel.: +60-1678-50269 (C.M.Y.); +60-1238-17752 (E.T.W.H.); +60-1927-87127 (N.H.B.H.)
| | - Eric Tatt Wei Ho
- Correspondence: (C.M.Y.); (E.T.W.H.); (N.H.B.H.); Tel.: +60-1678-50269 (C.M.Y.); +60-1238-17752 (E.T.W.H.); +60-1927-87127 (N.H.B.H.)
| | | | - Nor Hisham B. Hamid
- Correspondence: (C.M.Y.); (E.T.W.H.); (N.H.B.H.); Tel.: +60-1678-50269 (C.M.Y.); +60-1238-17752 (E.T.W.H.); +60-1927-87127 (N.H.B.H.)
| |
Collapse
|
31
|
Yan S, Zhang J, Yuan D, Li W. Hybrid microfluidics combined with active and passive approaches for continuous cell separation. Electrophoresis 2016; 38:238-249. [DOI: 10.1002/elps.201600386] [Citation(s) in RCA: 95] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 09/29/2016] [Accepted: 09/29/2016] [Indexed: 01/18/2023]
Affiliation(s)
- Sheng Yan
- School of Mechanical, Materials and Mechatronic Engineering; University of Wollongong; Wollongong Australia
| | - Jun Zhang
- School of Mechanical, Materials and Mechatronic Engineering; University of Wollongong; Wollongong Australia
- School of Mechanical Engineering; Nanjing University of Science and Technology; Nanjing P. R. China
| | - Dan Yuan
- School of Mechanical, Materials and Mechatronic Engineering; University of Wollongong; Wollongong Australia
| | - Weihua Li
- School of Mechanical, Materials and Mechatronic Engineering; University of Wollongong; Wollongong Australia
| |
Collapse
|
32
|
Shields CW, Ohiri KA, Szott LM, López GP. Translating microfluidics: Cell separation technologies and their barriers to commercialization. CYTOMETRY PART B-CLINICAL CYTOMETRY 2016; 92:115-125. [PMID: 27282966 DOI: 10.1002/cyto.b.21388] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 06/02/2016] [Accepted: 06/08/2016] [Indexed: 01/09/2023]
Abstract
Advances in microfluidic cell sorting have revolutionized the ways in which cell-containing fluids are processed, now providing performances comparable to, or exceeding, traditional systems, but in a vastly miniaturized format. These technologies exploit a wide variety of physical phenomena to manipulate cells and fluid flow, such as magnetic traps, sound waves and flow-altering micropatterns, and they can evaluate single cells by immobilizing them onto surfaces for chemotherapeutic assessment, encapsulate cells into picoliter droplets for toxicity screenings and examine the interactions between pairs of cells in response to new, experimental drugs. However, despite the massive surge of innovation in these high-performance lab-on-a-chip devices, few have undergone successful commercialization, and no device has been translated to a widely distributed clinical commodity to date. Persistent challenges such as an increasingly saturated patent landscape as well as complex user interfaces are among several factors that may contribute to their slowed progress. In this article, we identify several of the leading microfluidic technologies for sorting cells that are poised for clinical translation; we examine the principal barriers preventing their routine clinical use; finally, we provide a prospectus to elucidate the key criteria that must be met to overcome those barriers. Once established, these tools may soon transform how clinical labs study various ailments and diseases by separating cells for downstream sequencing and enabling other forms of advanced cellular or sub-cellular analysis. © 2016 International Clinical Cytometry Society.
Collapse
Affiliation(s)
- C Wyatt Shields
- NSF Research Triangle Materials Research Science and Engineering Center, Duke University, Durham, North Carolina, 27708.,Department of Biomedical Engineering, Duke University, Durham, North Carolina, 27708
| | - Korine A Ohiri
- NSF Research Triangle Materials Research Science and Engineering Center, Duke University, Durham, North Carolina, 27708.,Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina, 27708
| | - Luisa M Szott
- NSF Research Triangle Materials Research Science and Engineering Center, Duke University, Durham, North Carolina, 27708.,Department of Biomedical Engineering, Duke University, Durham, North Carolina, 27708
| | - Gabriel P López
- NSF Research Triangle Materials Research Science and Engineering Center, Duke University, Durham, North Carolina, 27708.,Department of Biomedical Engineering, Duke University, Durham, North Carolina, 27708.,Department of Mechanical Engineering and Materials Science, Duke University, Durham, North Carolina, 27708.,Center for Biomedical Engineering, Department of Chemical and Biological Engineering, University of New Mexico, Albuquerque, New Mexico, 87131
| |
Collapse
|
33
|
Yu X, Cheng G, Zheng SY. Synthesis of Self-Assembled Multifunctional Nanocomposite Catalysts with Highly Stabilized Reactivity and Magnetic Recyclability. Sci Rep 2016; 6:25459. [PMID: 27147586 PMCID: PMC4857104 DOI: 10.1038/srep25459] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Accepted: 04/18/2016] [Indexed: 01/21/2023] Open
Abstract
In this paper, a multifunctional Fe3O4@SiO2@PEI-Au/Ag@PDA nanocomposite catalyst with highly stabilized reactivity and magnetic recyclability was synthesized by a self-assembled method. The magnetic Fe3O4 nanoparticles were coated with a thin layer of the SiO2 to obtain a negatively charged surface. Then positively charged poly(ethyleneimine) polymer (PEI) was self-assembled onto the Fe3O4@SiO2 by electrostatic interaction. Next, negatively charged glutathione capped gold nanoparticles (GSH-AuNPs) were electrostatically self-assembled onto the Fe3O4@SiO2@PEI. After that, silver was grown on the surface of the nanocomposite due to the reduction of the dopamine in the alkaline solution. An about 5 nm thick layer of polydopamine (PDA) was observed to form the Fe3O4@SiO2@PEI-Au/Ag@PDA nanocomposite. The Fe3O4@SiO2@PEI-Au/Ag@PDA nanocomposite was carefully characterized by the SEM, TEM, FT-IR, XRD and so on. The Fe3O4@SiO2@PEI-Au/Ag@PDA nanocomposite shows a high saturation magnetization (Ms) of 48.9 emu/g, which allows it to be attracted rapidly to a magnet. The Fe3O4@SiO2@PEI-Au/Ag@PDA nanocomposite was used to catalyze the reduction of p-nitrophenol (4-NP) to p-aminophenol (4-AP) as a model system. The reaction kinetic constant k was measured to be about 0.56 min(-1) (R(2) = 0.974). Furthermore, the as-prepared catalyst can be easily recovered and reused for 8 times, which didn't show much decrease of the catalytic capability.
Collapse
Affiliation(s)
- Xu Yu
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Gong Cheng
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | - Si-Yang Zheng
- Micro & Nano Integrated Biosystem (MINIBio) Laboratory, Department of Biomedical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| |
Collapse
|
34
|
Tang M, Wen CY, Wu LL, Hong SL, Hu J, Xu CM, Pang DW, Zhang ZL. A chip assisted immunomagnetic separation system for the efficient capture and in situ identification of circulating tumor cells. LAB ON A CHIP 2016; 16:1214-23. [PMID: 26928405 DOI: 10.1039/c5lc01555c] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The detection of circulating tumor cells (CTCs), a kind of "liquid biopsy", represents a potential alternative to noninvasive detection, characterization and monitoring of carcinoma. Many previous studies have shown that the number of CTCs has a significant relationship with the stage of cancer. However, CTC enrichment and detection remain notoriously difficult because they are extremely rare in the bloodstream. Herein, aided by a microfluidic device, an immunomagnetic separation system was applied to efficiently capture and in situ identify circulating tumor cells. Magnetic nanospheres (MNs) were modified with an anti-epithelial-cell-adhesion-molecule (anti-EpCAM) antibody to fabricate immunomagnetic nanospheres (IMNs). IMNs were then loaded into the magnetic field controllable microfluidic chip to form uniform IMN patterns. The IMN patterns maintained good stability during the whole processes including enrichment, washing and identification. Apart from its simple manufacture process, the obtained microfluidic device was capable of capturing CTCs from the bloodstream with an efficiency higher than 94%. The captured cells could be directly visualized with an inverted fluorescence microscope in situ by immunocytochemistry (ICC) identification, which decreased cell loss effectively. Besides that, the CTCs could be recovered completely just by PBS washing after removal of the permanent magnets. It was observed that all the processes showed negligible influence on cell viability (viability up to 93%) and that the captured cells could be re-cultured for more than 5 passages after release without disassociating IMNs. In addition, the device was applied to clinical samples and almost all the samples from patients showed positive results, which suggests it could serve as a valuable tool for CTC enrichment and detection in the clinic.
Collapse
Affiliation(s)
- Man Tang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Cong-Ying Wen
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Ling-Ling Wu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Shao-Li Hong
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Jiao Hu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Chun-Miao Xu
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Dai-Wen Pang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| | - Zhi-Ling Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, and Wuhan Institute of Biotechnology, Wuhan University, Wuhan 430072, PR China.
| |
Collapse
|
35
|
Konry T, Sarkar S, Sabhachandani P, Cohen N. Innovative Tools and Technology for Analysis of Single Cells and Cell-Cell Interaction. Annu Rev Biomed Eng 2016; 18:259-84. [PMID: 26928209 DOI: 10.1146/annurev-bioeng-090215-112735] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Heterogeneity in single-cell responses and intercellular interactions results from complex regulation of cell-intrinsic and environmental factors. Single-cell analysis allows not only detection of individual cellular characteristics but also correlation of genetic content with phenotypic traits in the same cell. Technological advances in micro- and nanofabrication have benefited single-cell analysis by allowing precise control of the localized microenvironment, cell manipulation, and sensitive detection capabilities. Additionally, microscale techniques permit rapid, high-throughput, multiparametric screening that has become essential for -omics research. This review highlights innovative applications of microscale platforms in genetic, proteomic, and metabolic detection in single cells; cell sorting strategies; and heterotypic cell-cell interaction. We discuss key design aspects of single-cell localization and isolation in microfluidic systems, dynamic and endpoint analyses, and approaches that integrate highly multiplexed detection of various intracellular species.
Collapse
Affiliation(s)
- Tania Konry
- Department of Pharmaceutical Sciences, Northeastern University, Boston, Massachusetts 02115; , , ,
| | - Saheli Sarkar
- Department of Pharmaceutical Sciences, Northeastern University, Boston, Massachusetts 02115; , , ,
| | - Pooja Sabhachandani
- Department of Pharmaceutical Sciences, Northeastern University, Boston, Massachusetts 02115; , , ,
| | - Noa Cohen
- Department of Pharmaceutical Sciences, Northeastern University, Boston, Massachusetts 02115; , , ,
| |
Collapse
|
36
|
IIGUNI Y, TANAKA A, KITAGAWA S, OHTANI H. Staggered-electromagnetophoresis with a Split-flow System for the Separation of Microparticles by a Hollow Fiber-embedded PDMS Microchip. ANAL SCI 2016; 32:41-8. [DOI: 10.2116/analsci.32.41] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Yoshinori IIGUNI
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| | - Ayaka TANAKA
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| | - Shinya KITAGAWA
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| | - Hajime OHTANI
- Department of Materials Science and Engineering, Graduate School of Engineering, Nagoya Institute of Technology
| |
Collapse
|
37
|
Chung AJ, Hur SC. High-Speed Microfluidic Manipulation of Cells. ADVANCED MICRO AND NANOSYSTEMS 2015. [DOI: 10.1002/9783527690237.ch1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
38
|
Agostino FJ, Krylov SN. Advances in steady-state continuous-flow purification by small-scale free-flow electrophoresis. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.03.023] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
39
|
Shields CW, Reyes CD, López GP. Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation. LAB ON A CHIP 2015; 15:1230-49. [PMID: 25598308 PMCID: PMC4331226 DOI: 10.1039/c4lc01246a] [Citation(s) in RCA: 547] [Impact Index Per Article: 60.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Accurate and high throughput cell sorting is a critical enabling technology in molecular and cellular biology, biotechnology, and medicine. While conventional methods can provide high efficiency sorting in short timescales, advances in microfluidics have enabled the realization of miniaturized devices offering similar capabilities that exploit a variety of physical principles. We classify these technologies as either active or passive. Active systems generally use external fields (e.g., acoustic, electric, magnetic, and optical) to impose forces to displace cells for sorting, whereas passive systems use inertial forces, filters, and adhesion mechanisms to purify cell populations. Cell sorting on microchips provides numerous advantages over conventional methods by reducing the size of necessary equipment, eliminating potentially biohazardous aerosols, and simplifying the complex protocols commonly associated with cell sorting. Additionally, microchip devices are well suited for parallelization, enabling complete lab-on-a-chip devices for cellular isolation, analysis, and experimental processing. In this review, we examine the breadth of microfluidic cell sorting technologies, while focusing on those that offer the greatest potential for translation into clinical and industrial practice and that offer multiple, useful functions. We organize these sorting technologies by the type of cell preparation required (i.e., fluorescent label-based sorting, bead-based sorting, and label-free sorting) as well as by the physical principles underlying each sorting mechanism.
Collapse
Affiliation(s)
- C Wyatt Shields
- NSF Research Triangle Materials Research Science and Engineering Center, Duke University, Durham, NC 27708, USA.
| | | | | |
Collapse
|
40
|
Hejazian M, Li W, Nguyen NT. Lab on a chip for continuous-flow magnetic cell separation. LAB ON A CHIP 2015; 15:959-70. [PMID: 25537573 DOI: 10.1039/c4lc01422g] [Citation(s) in RCA: 192] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Separation of cells is a key application area of lab-on-a-chip (LOC) devices. Among the various methods, magnetic separation of cells utilizing microfluidic devices offers the merits of biocompatibility, efficiency, and simplicity. This review discusses the fundamental physics involved in using magnetic force to separate particles, and identifies the optimisation parameters and corresponding methods for increasing the magnetic force. The paper then elaborates the design considerations of LOC devices for continuous-flow magnetic cell separation. Examples from the recently published literature illustrate these state-of-the-art techniques.
Collapse
Affiliation(s)
- Majid Hejazian
- Queensland Micro- and Nanotechnology Centre, Griffith University, Brisbane, QLD 4111, Australia.
| | | | | |
Collapse
|
41
|
Wang G, Crawford K, Turbyfield C, Lam W, Alexeev A, Sulchek T. Microfluidic cellular enrichment and separation through differences in viscoelastic deformation. LAB ON A CHIP 2015; 15:532-40. [PMID: 25411722 DOI: 10.1039/c4lc01150c] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
We report a microfluidic approach to separate and enrich a mixture of two cell types based on differences in cell viscoelastic behavior during repeated compressions and relaxation events. As proof of concept, we demonstrate that variations in viscoelasticity affect the flow trajectory of one type of leukemia cell line (K562) in relation to another leukemia cell line (HL60) as well as healthy leukocytes. These differences in cell trajectory can be utilized to enrich and sort K562 cells from HL60 cells and leukocytes. The microfluidic device utilizes periodic, diagonal ridges to compress and translate the cells laterally perpendicular to channel axis. The ridge spacing is tuned to allow relaxation of the K562 cells but not the HL60 cells or leukocytes. Therefore, the periodic compression laterally translates weakly viscous cells, while highly viscous cells respond to hydrodynamic circulation forces generated by the slanted ridges. As a result, cell sorting has strong dependency on cell viscosity. We use atomic force microscopy and high-speed optical microscopy to measure cell stiffness, cell relaxation rate constant, and cell size for all cell types. With properly designed microfluidic channels, we can optimize the enrichment of K562 cells from HL60 and leukocytes.
Collapse
Affiliation(s)
- Gonghao Wang
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30332-0405, USA.
| | | | | | | | | | | |
Collapse
|
42
|
Plouffe BD, Murthy SK. Perspective on microfluidic cell separation: a solved problem? Anal Chem 2014; 86:11481-8. [PMID: 25350696 PMCID: PMC4255671 DOI: 10.1021/ac5013283] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2014] [Accepted: 10/28/2014] [Indexed: 12/28/2022]
Abstract
The purification and sorting of cells using microfluidic methodologies has been a remarkably active area of research over the past decade. Much of the scientific and technological work associated with microfluidic cell separation has been driven by needs in clinical diagnostics and therapeutic monitoring, most notably in the context of circulating tumor cells. The last several years have seen advances in a broad range of separation modalities ranging from miniaturized analogs of established techniques such as fluorescence- and magnetic-activated cell sorting (FACS and MACS, respectively), to more specialized approaches based on affinity, dielectrophoretic mobility, and inertial properties of cells. With several of these technologies nearing commercialization, there is a sense that the field of microfluidic cell separation has achieved a high level of maturity over an unusually short span of time. In this Perspective, we set the stage by describing major scientific and technological advances in this field and ask what the future holds. While many scientific questions remain unanswered and new compelling questions will undoubtedly arise, the relative maturity of this field poses some unique challenges.
Collapse
Affiliation(s)
- Brian D. Plouffe
- Department of Chemical Engineering and Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, Massachusetts 02115, United States
| | - Shashi K. Murthy
- Department of Chemical Engineering and Barnett Institute of Chemical and Biological Analysis, Northeastern University, Boston, Massachusetts 02115, United States
| |
Collapse
|