Montazerian H, Davoodi E, Baidya A, Badv M, Haghniaz R, Dalili A, Milani AS, Hoorfar M, Annabi N, Khademhosseini A, Weiss PS. Bio-macromolecular design roadmap towards tough bioadhesives. Chem Soc Rev 2022; 51:9127-9173. [PMID: 36269075 PMCID: PMC9810209 DOI: 10.1039/d2cs00618a] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Emerging sutureless wound-closure techniques have led to paradigm shifts in wound management. State-of-the-art biomaterials offer biocompatible and biodegradable platforms enabling high cohesion (toughness) and adhesion for rapid bleeding control as well as robust attachment of implantable devices. Tough bioadhesion stems from the synergistic contributions of cohesive and adhesive interactions. This Review provides a biomacromolecular design roadmap for the development of tough adhesive surgical sealants. We discuss a library of materials and methods to introduce toughness and adhesion to biomaterials. Intrinsically tough and elastic polymers are leveraged primarily by introducing strong but dynamic inter- and intramolecular interactions either through polymer chain design or using crosslink regulating additives. In addition, many efforts have been made to promote underwater adhesion via covalent/noncovalent bonds, or through micro/macro-interlock mechanisms at the tissue interfaces. The materials settings and functional additives for this purpose and the related characterization methods are reviewed. Measurements and reporting needs for fair comparisons of different materials and their properties are discussed. Finally, future directions and further research opportunities for developing tough bioadhesive surgical sealants are highlighted.
Collapse
Affiliation(s)
- Hossein Montazerian
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, USA.
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, California 90095, USA
- Terasaki Institute for Biomedical Innovation, Los Angeles, Los Angeles, California 90024, USA.
| | - Elham Davoodi
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, USA.
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, California 90095, USA
- Terasaki Institute for Biomedical Innovation, Los Angeles, Los Angeles, California 90024, USA.
- Multi-Scale Additive Manufacturing Lab, Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Avijit Baidya
- Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, Los Angeles, California 90095, USA.
| | - Maryam Badv
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, California 90095, USA
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, California 90095, USA
- Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Reihaneh Haghniaz
- Terasaki Institute for Biomedical Innovation, Los Angeles, Los Angeles, California 90024, USA.
| | - Arash Dalili
- School of Engineering, University of British Columbia, Kelowna, British Columbia V1V 1V7, Canada
| | - Abbas S Milani
- School of Engineering, University of British Columbia, Kelowna, British Columbia V1V 1V7, Canada
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, Kelowna, British Columbia V1V 1V7, Canada
- School of Engineering and Computer Science, University of Victoria, Victoria, British Columbia V8P 3E6, Canada
| | - Nasim Annabi
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, USA.
- Department of Chemical and Biomolecular Engineering, University of California, Los Angeles, Los Angeles, California 90095, USA.
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, Los Angeles, California 90024, USA.
| | - Paul S Weiss
- Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, USA.
- California NanoSystems Institute, University of California, Los Angeles, Los Angeles, California 90095, USA
- Department of Chemistry and Biochemistry, University of California, Los Angeles, Los Angeles, California 90095, USA
- Department of Materials Science and Engineering, University of California, Los Angeles, Los Angeles, California 90095, USA
| |
Collapse
|
2
|
Luka G, Samiei E, Tasnim N, Dalili A, Najjaran H, Hoorfar M. Comprehensive review of conventional and state-of-the-art detection methods of Cryptosporidium. J Hazard Mater 2022; 421:126714. [PMID: 34325293 DOI: 10.1016/j.jhazmat.2021.126714] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 07/06/2021] [Accepted: 07/19/2021] [Indexed: 06/13/2023]
Abstract
Cryptosporidium is a critical waterborne protozoan pathogen found in water resources that have been a major cause of death and serious illnesses worldwide, costing millions of dollars annually for its detection and treatment. Over the past several decades, substantial efforts have been made towards developing techniques for the detection of Cryptosporidium. Early diagnostic techniques were established based on the existing tools in laboratories, such as microscopes. Advancements in fluorescence microscopy, immunological, and molecular techniques have led to the development of several kits for the detection of Cryptosporidium spp. However, these methods have several limitations, such as long processing times, large sample volumes, the requirement for bulky and expensive laboratory tools, and the high cost of reagents. There is an urgent need to improve these existing techniques and develop low-cost, portable and rapid detection tools for applications in the water quality industry. In this review, we compare recent advances in nanotechnology, biosensing and microfluidics that have facilitated the development of sophisticated tools for the detection of Cryptosporidium spp.Finally, we highlight the advantages and disadvantages, of these state-of-the-art detection methods compared to current analytical methodologies and discuss the need for future developments to improve such methods for detecting Cryptosporidium in the water supply chain to enable real-time and on-site monitoring in water resources and remote areas.
Collapse
Affiliation(s)
- George Luka
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V1V7, Canada.
| | - Ehsan Samiei
- Department of Mechanical & Industrial Engineering, University of Toronto, Toronto, ON M5S 3G8, Canada.
| | - Nishat Tasnim
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V1V7, Canada.
| | - Arash Dalili
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V1V7, Canada.
| | - Homayoun Najjaran
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V1V7, Canada.
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, 3333 University Way, Kelowna, BC V1V1V7, Canada.
| |
Collapse
|
3
|
Taatizadeh E, Dalili A, Rellstab-Sánchez PI, Tahmooressi H, Ravishankara A, Tasnim N, Najjaran H, Li ITS, Hoorfar M. Micron-sized particle separation with standing surface acoustic wave-Experimental and numerical approaches. Ultrason Sonochem 2021; 76:105651. [PMID: 34242866 PMCID: PMC8267599 DOI: 10.1016/j.ultsonch.2021.105651] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 05/11/2021] [Accepted: 06/18/2021] [Indexed: 06/13/2023]
Abstract
Traditional cell/particle isolation methods are time-consuming and expensive and can lead to morphology disruptions due to high induced shear stress. To address these problems, novel lab-on-a-chip-based purification methods have been employed. Among various methods introduced for the separation and purification of cells and synthetics particles, acoustofluidics has been one of the most effective methods. Unlike traditional separation techniques carried out in clinical laboratories based on chemical properties, the acoustofluidic process relies on the physical properties of the sample. Using acoustofluidics, manipulating cells and particles can be achieved in a label-free, contact-free, and highly biocompatible manner. To optimize the functionality of the platform, the numerical study should be taken into account before conducting experimental tests to save time and reduce fabrication expenses. Most current numerical studies have only considered one-dimensional harmonic standing waves to simulate the acoustic pressure distribution. However, one-dimensional simulations cannot calculate the actual acoustic pressure distribution inside the microchannel due to its limitation in considering longitudinal waves. To address this limitation, a two-dimensional numerical simulation was conducted in this study. Our numerical simulation investigates the effects of the platform geometrical and operational conditions on the separation efficiency. Next, the optimal values are tested in an experimental setting to validate these optimal parameters and conditions. This work provides a guideline for future acoustofluidic chip designs with a high degree of reproducibility and efficiency.
Collapse
Affiliation(s)
- Erfan Taatizadeh
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada; Department of Chemistry, Irving K. Barber Faculty of Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada; School of Biomedical Engineering, Faculties of Applied Science and Medicine, The University of British Columbia, Vancouver, BC V6T 1Z3, Canada
| | - Arash Dalili
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Pamela Inés Rellstab-Sánchez
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Hamed Tahmooressi
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Adithya Ravishankara
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Nishat Tasnim
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Homayoun Najjaran
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Isaac T S Li
- Department of Chemistry, Irving K. Barber Faculty of Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada
| | - Mina Hoorfar
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC V1V 1V7, Canada.
| |
Collapse
|
4
|
Dalili A, Hoorfar M. Sheath-assisted versus sheathless dielectrophoretic particle separation. Electrophoresis 2021; 42:1570-1577. [PMID: 34196426 DOI: 10.1002/elps.202100029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 06/06/2021] [Accepted: 06/10/2021] [Indexed: 11/07/2022]
Abstract
Lab-on-chip devices are widely being used for binary and ternary cell/particle separation applications. Among the lab-on-chip methods, dielectrophoresis (DEP) is a cost-effective and label-free method, with great capabilities for size-based separation of cells and particles, which is mostly performed in sheath-assisted forms. However, the elimination of the sheath flows offers advantages such as ease of operation and higher sample throughput. In this work, we present a comparison of sheath-assisted and sheathless DEP separation of three sizes of microparticles using tilted electrodes. The sheath-assisted design was capable of separating the 5, 10, and 15 μm particles with a separation efficiency as high as 98.0% for 15 μm particles. By adding a DEP focusing region, a sheathless DEP separator was proposed, which offered higher throughputs (up to 10 times) at the cost of lowering the separation efficiency (a reduction up to 10.3% for 15 μm) compared to the sheath-assisted design. To enhance the separation efficiency, a combination of the DEP focusing accompanied by weak sheath flows from both sides was proposed. This design achieved the highest sample separation yield in the outlets (as high as 98.7% for 15 μm) with a sample throughput of more than 4.2 μL/min. This study provides insights into the choice of an appropriate platform for any application in which the yield, purity, throughput, and portability must be considered.
Collapse
Affiliation(s)
- Arash Dalili
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, Canada
| | - Mina Hoorfar
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, Canada
| |
Collapse
|
5
|
Dalili A, Sattati A, Tasnim N, Hoorfar M. Sheath-assisted focusing of microparticles on lab-on-a-chip platforms. Electrophoresis 2020; 41:2188-2196. [PMID: 33043482 DOI: 10.1002/elps.202000247] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/02/2020] [Accepted: 10/03/2020] [Indexed: 12/17/2022]
Abstract
Lab-on-a-chip (LOC) technologies can take advantage of sheath flows for particle/cell focusing before sensing or sorting. The integration of focusing with other microscale manipulation techniques (e.g., sorting) creates a trade-off between the throughput of the device and its performance. Therefore, exploring the effective parameters for cells/particles focusing enables us to improve the desired output of LOC devices. A common configuration for sheath-assisted focusing is Y junctions, which are parametrically studied in this paper. First, a computational model was developed and validated by comparing it with our experimental results. Using COMSOL Multiphysics modeling, the effects of multiple parameters were studied. These parameters include the sheath flow ratio (sheath flow over total flow), width ratio (width of the sheath inlet over the total width), junction angles, and particle size on the focusing width and the distribution of the particles within the focusing region. Then, the numerical data were used to develop two generalized linear models to predict the focusing width of the particles and the standard deviation of the position of the particles. The results showed that the focusing width is greatly impacted by the sheath flow rate ratio. Further, the standard deviation of the position of the particles, which represents the concentration of the particles, is mostly dependent on the flow rate ratio, width ratio, and particle size. Our results provide a better understanding of how the device geometrical and operational factors affect the position of the particles in the development of high-performance on-chip sensing and sorting of both cells and particles.
Collapse
Affiliation(s)
- Arash Dalili
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, Canada
| | - Amirmohammad Sattati
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, Canada
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Nishat Tasnim
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, Canada
| | - Mina Hoorfar
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, Canada
| |
Collapse
|
6
|
Dalili A, Taatizadeh E, Tahmooressi H, Tasnim N, Rellstab-Sánchez PI, Shaunessy M, Najjaran H, Hoorfar M. Parametric study on the geometrical parameters of a lab-on-a-chip platform with tilted planar electrodes for continuous dielectrophoretic manipulation of microparticles. Sci Rep 2020; 10:11718. [PMID: 32678180 PMCID: PMC7366698 DOI: 10.1038/s41598-020-68699-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 06/22/2020] [Indexed: 02/08/2023] Open
Abstract
Advances in lab-on-a-chip (LOC) devices have led to significant improvements in the on-chip manipulation, separation, sorting, and isolation of particles and cells. Among various LOC-based approaches such as inertia-based methods, acoustophoresis, and magnetophoresis, the planar-slanted-electrode dielectrophoresis (DEP) method has demonstrated great potential as a label-free, cost-effective, and user-friendly approach. However, the devices built based on this method suffer from low flow throughput compared to devices functioning based on other LOC-based manipulation approaches. In order to overcome this obstacle, the geometrical parameters of these types of DEP-based devices must be studied to increase the effectiveness of DEP manipulation. With the consideration of both numerical and experimental studies, this paper studies the geometrical factors of a LOC platform consisting of tilted planar electrodes with the goal of achieving higher throughput in continuous manipulation of polystyrene particles. COMSOL Multiphysics software was used to study the effect of the electrodes geometry on the induced electric field. The simulation results show that by increasing the electrode's width and decreasing the electrode's spacing, higher DEP force is generated. Furthermore, the experimental outcomes indicated that lower channel height, higher voltage, and larger particle size resulted in the most improvement to DEP manipulation. Additionally, the experimental results demonstrated that slanted electrodes with an angle of 8° with respect to the direction of flow provide a more effective configuration.
Collapse
Affiliation(s)
- Arash Dalili
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Erfan Taatizadeh
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
- School of Biomedical Engineering, Faculty of Applied Science, Faculty of Medicine, The University of British Columbia, Vancouver, BC, V6T 1Z3, Canada
| | - Hamed Tahmooressi
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Nishat Tasnim
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Pamela Inés Rellstab-Sánchez
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Matthew Shaunessy
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Homayoun Najjaran
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Mina Hoorfar
- School of Engineering, Faculty of Applied Science, The University of British Columbia, Kelowna, BC, V1V 1V7, Canada.
| |
Collapse
|
7
|
Yavarinasab A, Janfaza S, Tasnim N, Tahmooressi H, Dalili A, Hoorfar M. Graphene/poly (methyl methacrylate) electrochemical impedance-transduced chemiresistor for detection of volatile organic compounds in aqueous medium. Anal Chim Acta 2020; 1109:27-36. [DOI: 10.1016/j.aca.2020.02.065] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Revised: 02/26/2020] [Accepted: 02/29/2020] [Indexed: 12/14/2022]
|
8
|
Montazerian H, Rashidi A, Dalili A, Najjaran H, Milani AS, Hoorfar M. Graphene-Coated Spandex Sensors Embedded into Silicone Sheath for Composites Health Monitoring and Wearable Applications. Small 2019; 15:e1804991. [PMID: 30919566 DOI: 10.1002/smll.201804991] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 03/01/2019] [Indexed: 06/09/2023]
Abstract
This study presents a low-cost, tunable, and stretchable sensor fabricated based on spandex (SpX) yarns coated with graphene nanoplatelets (GnP) through a dip-coating process. The SpX/GnP is wrapped into a stretchable silicone rubber (SR) sheath to protect the conductive layer against harsh conditions, which allows for fabricating washable wearable sensors. Dip-coating parameters are optimized to obtain the maximum GnP coating rate. The covering sheath is tailored to achieve high stretchability beyond the sensing limit of 104% for SpX/GnP/SR sensors. Adjustable sensitivity is attained by manipulating SpX immersion times broadening its application for a wide range of strains: Gauge factors as high as two orders of magnitude are achieved at tensile strains greater than ≈40%. The fabricated sensors are tested for two applications: First, the SpX/GnP sensors are integrated into composite fabrics (with no negative impact on the structural integrity of the part) for screening the yarn displacements, resin flow, solidification during the hot press forming process, and structural health monitoring under mechanical loads with minimal cross-sensitivity to temperature/humidity. Second, the capability of SpX/GnP/SP sensors in detection of a wide range of bodily motions (from the joint motion to arterial blood pressure) is demonstrated.
Collapse
Affiliation(s)
- Hossein Montazerian
- School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Armin Rashidi
- School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Arash Dalili
- School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Homayoun Najjaran
- School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Abbas S Milani
- School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, Kelowna, BC, V1V 1V7, Canada
| |
Collapse
|
9
|
Dalili A, Samiei E, Hoorfar M. A review of sorting, separation and isolation of cells and microbeads for biomedical applications: microfluidic approaches. Analyst 2019; 144:87-113. [DOI: 10.1039/c8an01061g] [Citation(s) in RCA: 145] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
We have reviewed the microfluidic approaches for cell/particle isolation and sorting, and extensively explained the mechanism behind each method.
Collapse
Affiliation(s)
- Arash Dalili
- The University of British
- School of Engineering
- Kelowna
- Canada V1 V 1 V7
| | - Ehsan Samiei
- University of Victoria
- Department of Mechanical Engineering
- Victoria
- Canada
| | - Mina Hoorfar
- The University of British
- School of Engineering
- Kelowna
- Canada V1 V 1 V7
| |
Collapse
|
10
|
Soltani E, Jangjoo A, Afzal Aghaei M, Dalili A. Effects of preoperative administration of ginger (Zingiber officinale Roscoe) on postoperative nausea and vomiting after laparoscopic cholecystectomy. J Tradit Complement Med 2017; 8:387-390. [PMID: 29992109 PMCID: PMC6035306 DOI: 10.1016/j.jtcme.2017.06.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2016] [Revised: 01/16/2017] [Accepted: 06/21/2017] [Indexed: 12/01/2022] Open
Abstract
One of the most common postoperative problems is nausea and vomiting. Although using some anesthetic materials has been considered as the mainstay of this phenomenon, the exact factors are not known. Because of several morbidities associated with postoperative nausea and vomiting (PONV), its prevention and treatment has been a challenge for physicians, so several drugs have been recommended for this purpose. Based on the documented antiemetic specificity of ginger, we evaluated and compared the effects of preoperative administration of ginger on PONV with ondansetron administration as the standard medication. The participants included 100 patients with cholelitiasis who were candidate for laparoscopic cholecystectomy. Patients were divided into two groups: group A comprised 50 patients who received 500 mg oral ginger 1 h before surgery, and group B included 50 patients who received 4 mg intravenous ondansetron before completion of surgery. Antiemetic efficacy was assessed by visual analogue scale scores of nausea intensity at 0, 4, 8, 16, and 24 h after surgery and frequency of vomiting during the evaluation period. Although multifactor analysis showed that nausea severity was significantly lower in the ginger group, the data indicated that except 16 h after operation, the differences between two groups in the frequency of vomiting was not significant. In conclusion, though complementary studies are needed to have a strong suggestion, based on this study, we recommend administration of oral ginger 1 h before operation to control the severity of PONV in patients undergoing laparoscopic cholecystectomy.
Collapse
Affiliation(s)
- E Soltani
- Acute Care Surgery Research Center, Department of General Surgery, Taleghani University Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
| | - A Jangjoo
- Surgical Oncology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - M Afzal Aghaei
- Department of Epidemiology and Biostatistics, Faculty of Health Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - A Dalili
- Surgical Oncology Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
11
|
Dunstan T, Arthur JRF, Dalili A, Ogunbekun OO, Wong RKS. Limiting mechanisms of slow dilatant plastic shear deformation of granular media. Nature 1988. [DOI: 10.1038/336052a0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|