Willis LF, Kapur N, Radford SE, Brockwell DJ. Biophysical Analysis of Therapeutic Antibodies in the Early Development Pipeline. Biologics 2024; 18:413-432. [PMID: 39723199 PMCID: PMC11669289 DOI: 10.2147/btt.s486345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2024] [Accepted: 12/10/2024] [Indexed: 12/28/2024]
Abstract
The successful progression of therapeutic antibodies and other biologics from the laboratory to the clinic depends on their possession of "drug-like" biophysical properties. The techniques and the resultant biophysical and biochemical parameters used to characterize their ease of manufacture can be broadly defined as developability. Focusing on antibodies, this review firstly discusses established and emerging biophysical techniques used to probe the early-stage developability of biologics, aimed towards those new to the field. Secondly, we describe the inter-relationships and redundancies amongst developability assays and how in silico methods aid the efficient deployment of developability to bring a new generation of cost-effective therapeutic proteins from bench to bedside more quickly and sustainably.
Collapse
Affiliation(s)
- Leon F Willis
- School of Molecular and Cellular Biology, Astbury Centre for Structural Molecular Biology, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT, UK
| | - Nikil Kapur
- School of Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Leeds, Leeds, LS2 9JT, UK
| | - Sheena E Radford
- School of Molecular and Cellular Biology, Astbury Centre for Structural Molecular Biology, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT, UK
| | - David J Brockwell
- School of Molecular and Cellular Biology, Astbury Centre for Structural Molecular Biology, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
2
|
Höchsmann A, Dhellemmes L, Leclercq L, Cottet H, Neusüß C. Charge variant analysis of monoclonal antibodies by CZE-MS using a successive multiple ionic-polymer layer coating based on diethylaminoethyl-dextran. Electrophoresis 2024. [PMID: 39287066 DOI: 10.1002/elps.202400084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2024] [Revised: 08/09/2024] [Accepted: 08/21/2024] [Indexed: 09/19/2024]
Abstract
The characterization of the impurities of pharmaceutical monoclonal antibodies (mAbs) is crucial for their function and safety. Capillary zone electrophoresis (CZE) is one of the most efficient tools to separate charge variants of mAbs; however, peak characterization remains difficult, since the hereby used background electrolytes (BGEs) are not compatible with electrospray ionization-mass spectrometry (ESI-MS). Here, a method that allows the separation of intact mAb charge variants is presented using CZE-ESI-MS, combining a cationic capillary coating and an acidic BGE. Therefore, a successive multiple ionic-polymer layer coating was developed based on diethylaminoethyl-dextran-poly(sodium styrene sulfonate). This coating leads to a relatively low reversed electroosmotic flow (EOF) with an absolute mobility slightly higher than that of antibodies, enabling the separation of variants with slightly different mobilities. The potential of the coating is demonstrated using USP mAb003, where it was possible to separate C-terminal lysine variants from the main form, as well as several acidic variants and monoglycosylated mAb forms. The presented CZE-MS method can be applied to separate charge variants of a range of other antibodies such as infliximab, NISTmAB (Reference Material from the National Institute of Standards and Technology), adalimumab, and trastuzumab, demonstrating the general applicability for the separation of proteoforms of mAbs.
Collapse
Affiliation(s)
- Alisa Höchsmann
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Faculty of Science, Eberhard Karls University of Tübingen, Tübingen, Germany
| | - Laura Dhellemmes
- IBMM, University of Montpellier, CNRS, ENSCM, Montpellier, France
| | - Laurent Leclercq
- IBMM, University of Montpellier, CNRS, ENSCM, Montpellier, France
| | - Hervé Cottet
- IBMM, University of Montpellier, CNRS, ENSCM, Montpellier, France
| | | |
Collapse
|
3
|
Cageling R, Carillo S, Boumeester AJ, Lubbers-Geuijen K, Bones J, Jooß K, Somsen GW. Microfluidic capillary electrophoresis - mass spectrometry for rapid charge-variant and glycoform assessment of monoclonal antibody biosimilar candidates. J Pharm Biomed Anal 2024; 248:116301. [PMID: 38901155 DOI: 10.1016/j.jpba.2024.116301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/04/2024] [Accepted: 06/08/2024] [Indexed: 06/22/2024]
Abstract
Early-stage cell line screening is a vital step in developing biosimilars of therapeutic monoclonal antibodies (mAbs). While the quality of the manufactured antibodies is commonly assessed by charge-based separation methods employing UV absorbance detection, these methods lack the ability to identify resolved mAb variants. We evaluated the performance of microfluidic capillary electrophoresis coupled to mass spectrometry (MCE-MS) as a rapid tool for profiling mAb biosimilar candidates from clonal cell lines. A representative originator sample was used to develop the MCE-MS method. The addition of dimethylsulfoxide (DMSO) to the background electrolyte yielded up to 60-fold enhancement of the protein MS signal. The resulting electropherograms consistently provided resolution of mAb charge variants within 10 min. Deconvoluted mass spectra facilitated the identification of basic variants such as C-terminal lysine and proline amidation, while the acidic variants could be assigned to deamidated forms. The MCE-MS method also allowed the identification of 18 different glycoforms in biosimilar samples. To mimic early-stage cell line selection, samples from five clonal cell lines that all expressed the same biosimilar candidate mAb were compared to their originator mAb. Based on the similarity observed in charge variants and glycoform profiles acquired by MCE-MS, the most promising candidate could be selected. The MCE-MS method demonstrated good overall reproducibility, as confirmed by a transferability study involving two separate laboratories. This study highlights the efficacy of the MCE-MS method for rapid proteoform screening of clonal cell line samples, underscoring its potential significance as an analytical tool in biosimilar process development.
Collapse
Affiliation(s)
- Ruben Cageling
- Analytical Development, Polpharma Biologics, Yalelaan 46, Utrecht, 3584 CM, the Netherlands; Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, Amsterdam, 1081 HV, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, the Netherlands
| | - Sara Carillo
- National Institute for Bioprocessing Research and Training, Fosters Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland
| | - Anja J Boumeester
- Analytical Development, Polpharma Biologics, Yalelaan 46, Utrecht, 3584 CM, the Netherlands
| | - Karin Lubbers-Geuijen
- Analytical Development, Polpharma Biologics, Yalelaan 46, Utrecht, 3584 CM, the Netherlands
| | - Jonathan Bones
- National Institute for Bioprocessing Research and Training, Fosters Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland; School of Chemical and Bioprocess Engineering, University College Dublin, Belfield, Dublin 4, D04 V1W8, Ireland
| | - Kevin Jooß
- Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, Amsterdam, 1081 HV, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, the Netherlands.
| | - Govert W Somsen
- Division of BioAnalytical Chemistry, Department of Chemistry and Pharmaceutical Sciences, Vrije Universiteit Amsterdam, de Boelelaan 1085, Amsterdam, 1081 HV, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, the Netherlands
| |
Collapse
|
4
|
Wang Z, Li M, Xu S, Sun L, Li L. High-throughput relative quantification of fatty acids by 12-plex isobaric labeling and microchip capillary electrophoresis - Mass spectrometry. Anal Chim Acta 2024; 1318:342905. [PMID: 39067909 PMCID: PMC11299455 DOI: 10.1016/j.aca.2024.342905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 06/23/2024] [Indexed: 07/30/2024]
Abstract
BACKGROUND Fatty acids (FAs) are essential cellular components and play important roles in various biological processes. Importantly, FAs produced by microorganisms from renewable sugars are considered sustainable substrates for biodiesels and oleochemicals. Their complex structures and diverse functional roles in biochemical processes necessitate the development of efficient and accurate methods for their quantitative analysis. RESULTS Here, we developed a novel method for relative quantification of FAs by combining 12-plex isobaric N,N-dimethyl leucine-derivatized ethylenediamine (DiLeuEN) labeling and microchip capillary electrophoresis-mass spectrometry (CE-MS). This method enables simultaneous quantification of 12 samples in a single MS analysis. DiLeuEN labeling introduced tertiary amine center structure into FAs, which makes them compatible with the positive mode separation of commercial microchip CE systems and further improves the sensitivity. The CE separation parameters were optimized, and the quantification accuracy was assessed using FA standards. Microchip CE-MS detection exhibited high sensitivity with a femtomole level detection limit and a total analysis time within 8 min. Finally, the applicability of our method to complex biological samples was demonstrated by analyzing FAs produced by four industrially relevant yeast strains (Saccharomyces cerevisiae, Yarrowia lipolytica YB-432, Yarrowia lipolytica Po1f and Rhodotorula glutinis). The analysis time for each sample is less than 1 min. SIGNIFICANCE This work addresses the current challenges in the field by introducing a method that combines microchip-based capillary electrophoresis separation with multiplex isobaric labeling. Our method not only offers remarkable sensitivity and rapid analysis speed but also the capability to quantify fatty acids across multiple samples simultaneously, which holds significant potential for extensive application in FA quantitative studies in diverse research areas, promising an enhanced understanding of FA functions and mechanisms.
Collapse
Affiliation(s)
- Zicong Wang
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Miyang Li
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706, USA
| | - Shuling Xu
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Liang Sun
- Great Lakes Bioenergy Research Center, University of Wisconsin-Madison, Madison, WI, 53726, USA
| | - Lingjun Li
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA; Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706, USA; Lachman Institute for Pharmaceutical Development, School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA; Wisconsin Center for NanoBioSystems, School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA.
| |
Collapse
|
5
|
Wu Z, Wang H, Zhao X, Gong C, Sidnam S, Cantero-Tubilla B, Nedjic-Dugic B, Li M, Wu J, Su Y, Huang Y, Qiu H, Li N. Characterization of Therapeutic Antibody Charge Heterogeneity Under Stress Conditions by Microfluidic Capillary Electrophoresis Coupled with Mass Spectrometry. J Pharm Sci 2024; 113:2170-2177. [PMID: 38796156 DOI: 10.1016/j.xphs.2024.05.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 05/15/2024] [Accepted: 05/16/2024] [Indexed: 05/28/2024]
Abstract
Therapeutic antibodies are a major class of biopharmaceutics that are applied in disease treatment because of their many advantages, including high specificity and high affinity to molecular targets. Between their production and administration, therapeutic antibodies are exposed to multiple stress conditions. Forced degradation and stress stability studies are conducted to simulate the risk of degradation and the effects of these stresses, thereby enhancing understanding of the drug product to support strategies to mitigate the impact from stressed conditions. These types of studies are also routinely conducted to evaluate product comparability when major process changes are implemented during the production. Charge variant analysis helps understand the changes in the electrostatic environment of biotherapeutics and can uncover underlying molecular level alterations associated with charge variants. Herein, we used ZipChip native capillary electrophoresis-mass spectrometry (nCE-MS) to elucidate the changes in charge variant profiles at the molecular level. In two case studies under thermal stress conditions, we observed that charge variants arose from both post-translational modifications (including deamidation, oxidation, and pyroglutamate formation) and sequence truncations at the hinge regions. Under oxidative stress conditions, oxidation was found to be the major contributor to the changes in the charge variant profiles. Under pH stress conditions, the changes in the charge variant profile were due to increased levels of deamidation, oxidation, and pyroglutamate formation. ZipChip nCE-MS analysis enables identification of charge variant species under various stress conditions, thus supporting process and formulation development of biotherapeutics.
Collapse
Affiliation(s)
- Zhijie Wu
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA.
| | - Hongxia Wang
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Xueqing Zhao
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Chao Gong
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Sarah Sidnam
- CMC Regulatory Sciences, Regeneron Pharmaceuticals Inc., Rensselaer, NY, USA
| | | | | | - Meinuo Li
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Jikang Wu
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Yue Su
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Yu Huang
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Haibo Qiu
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA.
| | - Ning Li
- Analytical Chemistry, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| |
Collapse
|
6
|
Rollo D, Kulkarni A, Yu K, Fabris D. Investigating the Merits of Microfluidic Capillary Zone Electrophoresis-Mass Spectrometry (CZE-MS) in the Bottom-Up Characterization of Larger RNAs. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:561-574. [PMID: 38350102 DOI: 10.1021/jasms.3c00411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
Established bottom-up approaches for the characterization of nucleic acids (NAs) rely on the strand-cleavage activity of nucleotide-specific endonucleases to generate smaller oligonucleotides amenable to gas-phase sequencing. The complexity of these hydrolytic mixtures calls for the utilization of a front-end separation to facilitate full mass spectrometric (MS) characterization. This report explored the merits of microfluidic capillary zone electrophoresis (CZE) as a possible alternative to common liquid chromatography techniques. An oligonucleotide ladder was initially employed to investigate the roles of fundamental analyte features and experimental parameters in determining the outcome of CZE-MS analyses. The results demonstrated the ability to fully resolve the various rungs into discrete electrophoretic peaks with full-width half-height (FWHH) resolution that was visibly affected by the overall amount of material injected into the system. Analogous results were obtained from a digestion mixture prepared by treating yeast tRNAPhe (75 nt) with RNase T1, which provided several well-resolved peaks in spite of the increasing sample heterogeneity. The regular shapes of such peaks, however, belied the fact that most of them contained sets of comigrating species, as shown by the corresponding MS spectra. Even though it was not possible to segregate each species into an individual electrophoretic peak, the analysis still proved capable of unambiguously identifying a total of 29 hydrolytic products, which were sufficient to cover 96% of the tRNAPhe's sequence. Their masses accurately reflected the presence of modified nucleotides characteristic of this type of substrate. The analysis of a digestion mixture obtained from the 364 nt HIV-1 5'-UTR proved to be more challenging. The electropherogram displayed fewer well-resolved peaks and significantly greater incidence of product comigration. In this case, fractionating the highly heterogeneous mixture into discrete bands helped reduce signal suppression and detection bias. As a result, the corresponding MS data enabled the assignment of 248 products out of the possible 513 predicted from the 5'-UTR sequence, which afforded 100% sequence coverage. This figure represented a significant improvement over the 36 total products identified earlier under suboptimal conditions, which afforded only 57% coverage, or the 83 observed by direct infusion nanospray-MS (72%). These results provided a measure of the excellent potential of the technique to support the bottom-up characterization of progressively larger NA samples, such as putative NA therapeutics and mRNA vaccines.
Collapse
Affiliation(s)
- Daniele Rollo
- University of Connecticut, Storrs, Connecticut 06269, United States
| | | | - Kate Yu
- 908 Devices, Boston, Massachusetts 02210, United States
| | - Daniele Fabris
- University of Connecticut, Storrs, Connecticut 06269, United States
| |
Collapse
|
7
|
Schwenzer AK, Kruse L, Jooß K, Neusüß C. Capillary electrophoresis-mass spectrometry for protein analyses under native conditions: Current progress and perspectives. Proteomics 2024; 24:e2300135. [PMID: 37312401 DOI: 10.1002/pmic.202300135] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 05/16/2023] [Accepted: 05/23/2023] [Indexed: 06/15/2023]
Abstract
Native mass spectrometry is a rapidly emerging technique for fast and sensitive structural analysis of protein constructs, maintaining the protein higher order structure. The coupling with electromigration separation techniques under native conditions enables the characterization of proteoforms and highly complex protein mixtures. In this review, we present an overview of current native CE-MS technology. First, the status of native separation conditions is described for capillary zone electrophoresis (CZE), affinity capillary electrophoresis (ACE), and capillary isoelectric focusing (CIEF), as well as their chip-based formats, including essential parameters such as electrolyte composition and capillary coatings. Further, conditions required for native ESI-MS of (large) protein constructs, including instrumental parameters of QTOF and Orbitrap systems, as well as requirements for native CE-MS interfacing are presented. On this basis, methods and applications of the different modes of native CE-MS are summarized and discussed in the context of biological, medical, and biopharmaceutical questions. Finally, key achievements are highlighted and concluded, while remaining challenges are pointed out.
Collapse
Affiliation(s)
| | - Lena Kruse
- Department of Chemistry, Aalen University, Aalen, Germany
| | - Kevin Jooß
- Department of Chemistry and Molecular Biosciences, the Chemistry of Life Processes Institute, and the Proteomics Center of Excellence, Northwestern University, Evanston, Illinois, USA
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | | |
Collapse
|
8
|
Atia MA, Smejkal P, Gupta V, Haddad PR, Breadmore MC. Chemical vapour deposition in narrow capillaries: Electro-osmotic flow control in capillary electrophoresis. Anal Chim Acta 2023; 1280:341847. [PMID: 37858546 DOI: 10.1016/j.aca.2023.341847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 09/05/2023] [Accepted: 09/23/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND In capillary electrophoresis (CE), the inner surface of fused-silica capillaries is commonly covalently modified with liquid silanes to control electroosmotic flow (EOF). This liquid phase deposition (LPD) approach is challenging for long and narrow-diameter capillaries (≥1 m, ≤25 μm ID) inhibiting commercial production. Here, we use chemical vapour deposition (CVD) to covalently modify capillaries with different silanes. Using a home-built CVD device, capillaries were modified with neutral (3-glycidyloxypropyl) trimethoxysilane (GPTMS), the weak base (3-aminopropyl) trimethoxysilane (APTMS), the weak acid 3-mercaptopropyltrimethoxysilane (MPTMS) and the neutral hydrophobic trichloro(1H,1H,2H,2H-perfluorooctyl) silane (PFOCTS). Gas-phase modification of GPTMS with acid and ammonia allowed further modification of the surface prior to molecular layer deposition (MLD) of poly(p-phenylene terephthalamide) (PPTA) using the self-limiting sequential reaction between terephthalaldehyde (TA) and p-phenylenediamine (PD) vapours. RESULTS Capillaries coated with GPTMS by CVD showed a greater reduction in EOF at all pH values than the conventional LPD. APTMS showed a reduction of the EOF at pH 9, with EOF reversal observed below pH 6. MPTMS provided a slightly lower EOF than an unmodified capillary at high pH, and a slightly higher EOF at lower pH. PFOCTS provided the most consistent EOF as a function of pH. The deposition of successive layers of PPTA resulted in increased surface coverage of the polymer and a greater reduction in EOF at pH higher than 5. The stability of a 10 μm ID GPTMS coated capillary was tested at pH 8.8 in a 200 mM CHES/Tris BGE for the separation of inorganic anions. Over 1.5 months of continuous operation (≈4130 runs), the reproducibility of the apparent mobilities for chloride, nitrite, nitrate and sulfate were 2.43%, 2.56%, 2.63% and 3.05%, respectively. The intra-day and inter-day column-to-column reproducibility and batch-to-batch reproducibility for all the coated capillaries ranged between 0.34% and 3.95%. SIGNIFICANCE The study demonstrates the superior performance of CVD coating for suppressing the EOF compared to LPD allowing the easy modification of long lengths of narrow capillary. The variation in silane, and the ability of MLD to modify and control the surface chemistry, provides a simple and facile method for surface modification. The stability of these coatings will allow long-term capillary electrophoresis monitoring of water chemistry, such as for monitoring fertiliser run-off in natural waters.
Collapse
Affiliation(s)
- Mostafa A Atia
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia; Department of Analytical Chemistry, Faculty of Pharmacy Helwan University, 11795, Cairo, Egypt.
| | - Petr Smejkal
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia.
| | - Vipul Gupta
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia.
| | - Paul R Haddad
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia.
| | - Michael C Breadmore
- Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania, 7001, Australia.
| |
Collapse
|
9
|
Füssl F, Carillo S, Millán-Martín S, Jakes C, Bora K, Liberatori S, Graham J, Bones J. Exploring proteoforms of the IgG2 monoclonal antibody panitumumab using microchip capillary electrophoresis-mass spectrometry. J Pharm Biomed Anal 2023; 234:115494. [PMID: 37300951 DOI: 10.1016/j.jpba.2023.115494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 05/23/2023] [Accepted: 05/27/2023] [Indexed: 06/12/2023]
Abstract
The IgG2 type monoclonal antibody panitumumab is an anti-epidermal growth factor receptor (EGFR) drug used for the treatment of EGFR-expressing, chemotherapy resistant, metastatic colorectal carcinoma. In this study, panitumumab drug product was first analysed using size exclusion chromatography coupled to mass spectrometry for rapid identity testing. The experimental data led to the identification of two panitumumab isoforms with several prominent forms remaining unidentified, despite apparently low sample complexity. Microchip capillary electrophoresis-mass spectrometry (CE-MS) was subsequently utilised for a more detailed characterization. It was observed that panitumumab is subject to partial N-terminal pyroglutamate formation. Incomplete conversion is uncharacteristic for N-terminally exposed glutamines and in case of panitumumab gives rise to forms which show successive mass offsets of 17 Da, respectively. If not separated before mass spectrometric analysis, e.g. by capillary electrophoresis, such near isobaric species coalesce into single MS peaks, which subsequently hampers or prevents their assignment. With a total of 42 panitumumab isoforms assigned by CE-MS, these observations highlight a potential pitfall of commonly applied rapid identity testing workflows and demonstrate that even low complexity biopharmaceuticals can require separation strategies which offer high separation selectivity for species close in mass.
Collapse
Affiliation(s)
- Florian Füssl
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland
| | - Sara Carillo
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland
| | - Silvia Millán-Martín
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland
| | - Craig Jakes
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland
| | - Karina Bora
- Lonza Biologics, 224 Bath Road, Slough SL1 4DX, United Kingdom
| | | | - James Graham
- Lonza Biologics, 224 Bath Road, Slough SL1 4DX, United Kingdom
| | - Jonathan Bones
- National Institute for Bioprocessing Research & Training, Fosters Avenue, Mount Merrion, Blackrock, A94 X099 Co. Dublin, Ireland; School of Chemical and Bioprocess Engineering, University College Dublin, Belfield, Dublin 4 D04 V1W8 Ireland.
| |
Collapse
|
10
|
Schneider MM, Scheidt T, Priddey AJ, Xu CK, Hu M, Meisl G, Devenish SRA, Dobson CM, Kosmoliaptsis V, Knowles TPJ. Microfluidic antibody affinity profiling of alloantibody-HLA interactions in human serum. Biosens Bioelectron 2023; 228:115196. [PMID: 36921387 DOI: 10.1016/j.bios.2023.115196] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 02/17/2023] [Accepted: 03/03/2023] [Indexed: 03/07/2023]
Abstract
Antibody profiling is a fundamental component of understanding the humoral response in a wide range of disease areas. Most currently used approaches operate by capturing antibodies onto functionalised surfaces. Such measurements of surface binding are governed by an overall antibody titre, while the two fundamental molecular parameters, antibody affinity and antibody concentration, are challenging to determine individually from such approaches. Here, by applying microfluidic diffusional sizing (MDS), we show how we can overcome this challenge and demonstrate reliable quantification of alloantibody binding affinity and concentration of alloantibodies binding to Human Leukocyte Antigens (HLA), an extensively used clinical biomarker in organ transplantation, both in buffer and in crude human serum. Capitalising on the ability to vary both serum and HLA concentrations during MDS, we show that both affinity and concentration of HLA-specific antibodies can be determined directly in serum when neither of these parameters is known. Finally, we provide proof of principle in clinical transplant patient sera that our assay enables differentiation of alloantibody reactivity against HLA proteins of highly similar structure, providing information not attainable through currently available techniques. These results outline a path towards detection and in-depth profiling of humoral immunity and may enable further insights into the clinical relevance of antibody reactivity in clinical transplantation and beyond.
Collapse
Affiliation(s)
- Matthias M Schneider
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Tom Scheidt
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Ashley J Priddey
- Department of Surgery, University of Cambridge, Addenbrooke's Hospital, Hills Road, Cambridge, CB2 0QQ, UK
| | - Catherine K Xu
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Mengsha Hu
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Georg Meisl
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Sean R A Devenish
- Fluidic Analytics, Unit A, The Paddocks Business Centre, Cherry Hinton Rd, Cambridge, CB1 8DH, UK
| | - Christopher M Dobson
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK
| | - Vasilis Kosmoliaptsis
- Department of Surgery, University of Cambridge, Addenbrooke's Hospital, Hills Road, Cambridge, CB2 0QQ, UK; NIHR Blood and Transplant Research Unit in Organ Donation and Transplantation, University of Cambridge, Hills Road, Cambridge, CB2 0QQ, UK; NIHR Cambridge Biomedical Research Centre, Hills Road, Cambridge, CB2 0QQ, UK.
| | - Tuomas P J Knowles
- Centre for Misfolding Diseases, Yusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge, CB2 1EW, UK; Cavendish Laboratory, Department of Physics, University of Cambridge, JJ Thomson Ave, Cambridge, CB3 0HE, UK.
| |
Collapse
|
11
|
Schmidt AJ, Zamuruyev KO, LeVasseur MK, Fung S, Anishchenko IM, Kenyon NJ, Davis CE. Stable electrospray signal on a microfabricated glass chip with three-dimensional open edge and tiered depth geometries. MICROELECTRONIC ENGINEERING 2023; 276:111997. [PMID: 39301435 PMCID: PMC11412618 DOI: 10.1016/j.mee.2023.111997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
This paper presents the microfabrication and performance of a three-dimensional electrospray ionization (ESI) emitter tip made from glass, which achieves stable current signals important for chemical analysis. Our novel microfabrication process and custom-built signal conditioning hardware provides the advantage of providing accurate features and steady signals. The fabrication process relies on standard microfabrication techniques (i.e., deposition, photolithography, and wet etching). This fabrication method involves the novel application of two layers of positive and negative photoresists in addition to Parafilm® wax tape. Open edge and tiered depth details were successfully created from a multilayer planar mask. This is a benefit for integrated miniaturized and microfluidic systems that often require micro features for their functionality but relatively large millimeter size features for their physical periphery. We demonstrate the fundamental performance of electrospray with this microfluidic chip. The emitter tip was fixed on a linear axis stage with high resolution (10 μm) to finely control the tip distance from a metal counter electrode plate. A custom printed circuit board system was built to safely control four voltages applied to the microchip ports from a single high voltage power supply. To readily form the electrospray, non-aqueous solvents were used for their low viscosity and a constant voltage of +2.7 kV was applied to the sheath electrospray microchannel. The liquid being sprayed was 80/20 (v/v) methanol/acetonitrile with 0.1% acetic acid in the sheath microchannel and with ammonium acetate (10-40 mM) in its remaining microchannels. The electrospray signal was measured in response to varying the distance (1.4 to 1.6 mm) between the electrospray emitter tip and a metal counter electrode plate in addition to the varying concentration of the background electrolyte, ammonium acetate. Stable and repeatable electrospray signal showed linear relationships with emitter tip distance and concentration (r2≥0.95).
Collapse
Affiliation(s)
- Alexander J Schmidt
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Konstantin O Zamuruyev
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Michael K LeVasseur
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Stephanie Fung
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Ilya M Anishchenko
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
| | - Nicholas J Kenyon
- UC Davis Lung Center, Davis CA, USA
- VA Northern California Health Care System, Mather CA, USA
- Department of Internal Medicine, UC Davis, Sacramento CA, USA
| | - Cristina E Davis
- Department of Mechanical and Aerospace Engineering, UC Davis, Davis, CA 95616, USA
- UC Davis Lung Center, Davis CA, USA
- VA Northern California Health Care System, Mather CA, USA
| |
Collapse
|
12
|
Cotham VC, Liu AP, Wang S, Li N. A generic platform to couple affinity chromatography with native mass spectrometry for the analysis of therapeutic monoclonal antibodies. J Pharm Biomed Anal 2023; 228:115337. [PMID: 36933319 DOI: 10.1016/j.jpba.2023.115337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/06/2023] [Accepted: 03/10/2023] [Indexed: 03/16/2023]
Abstract
Affinity chromatography coupled with native mass spectrometry has emerged as a powerful tool for the analysis of therapeutic monoclonal antibodies (mAbs). Exploiting the specific interactions between mAbs and their ligands, these methods not only provide orthogonal means to study the highly complex mAb attributes, but also offer insights on their biological relevance. Despite the great promise, application of affinity chromatography - native mass spectrometry in routine mAb characterization has been limited, largely due to the complicated experimental set up. In this study, we introduced a generic platform to facilitate the online coupling of different affinity separation modes with native mass spectrometry. Built upon a recently introduced native LC-MS platform, this new strategy can accommodate a wide range of chromatographic conditions, and therefore, allow greatly simplified experimental set up and facile swapping of affinity separation modes. The utility of this platform was demonstrated by successful online coupling of three affinity chromatography methods (protein A, FcγRIIIa, and FcRn) with native mass spectrometry. The developed protein A-MS method was tested both in a "bind-and-elute" mode for rapid mAb screening and in a high-resolution resolving mode to study mAb species with altered protein A affinity. The FcγRIIIa-MS method was applied to achieve glycoform-resolved analyses of both IgG1 and IgG4 subclass molecules. The FcRn-MS method was demonstrated in two case studies, where specific post-translational modifications and Fc mutations were known to alter FcRn affinities.
Collapse
Affiliation(s)
- Victoria C Cotham
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Anita P Liu
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| | - Shunhai Wang
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA.
| | - Ning Li
- Analytical Chemistry Group, Regeneron Pharmaceuticals Inc., Tarrytown, NY, USA
| |
Collapse
|
13
|
Shah A, Desai R, Cui W, Harrahy JJ, Ivanov AR. Characterization of bispecific antigen-binding biotherapeutic fragmentation sites using microfluidic capillary electrophoresis coupled to mass spectrometry (mCZE-MS). Analyst 2023; 148:665-674. [PMID: 36625279 PMCID: PMC9979615 DOI: 10.1039/d2an01724e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Fragmentation of therapeutic proteins is a potential critical quality attribute (CQA) that can occur in vivo or during manufacturing or storage due to enzymatic and non-enzymatic degradation pathways, such as hydrolysis, peroxide mediation, and acid/metal catalysis. Characterization of the fragmentation pattern of a therapeutic protein is traditionally accomplished using capillary gel electrophoresis with UV detection under both non-reducing and reducing conditions (nrCGE and rCGE). However, such methods are incompatible with direct coupling to mass spectrometry (MS) due to the use of anionic surfactants, e.g., sodium dodecyl sulfate (SDS). Here, we present a novel method to characterize size-based fragmentation variants of a new biotherapeutic kind using microfluidic ZipChip® capillary zone electrophoresis (mCZE) system interfaced with mass spectrometry (MS) to determine the molecular masses of fragments. A new modality of immuno-oncology therapy, bispecific antigen-binding biotherapeutic, was chosen to investigate its fragmentation pattern using mCZE-MS for the first time, according to our knowledge. Bispecific antigen-binding biotherapeutic samples from different stages of downstream column purification and forced degradation conditions were analyzed. The results were cross-validated with denaturing size-exclusion chromatography-mass spectrometry and conventional rSDS-CGE. In this study, we demonstrated that mCZE-MS could separate and characterize 12-40 kDa bispecific antigen-binding biotherapeutic fragments rapidly (within ≤12 minutes), with higher resolution and better sensitivity than traditional LC-MS methods.
Collapse
Affiliation(s)
- Arnik Shah
- Amgen Inc, Attribute Science, 360 Binney Street, Cambridge, Massachusetts 02141, USA
- Barnett Institute of Chemical and Biological Analysis, Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Ave., Boston, Massachusetts 02115, USA.
| | - Ruhi Desai
- Amgen Inc, Attribute Science, 360 Binney Street, Cambridge, Massachusetts 02141, USA
| | - Weidong Cui
- Amgen Inc, Attribute Science, 360 Binney Street, Cambridge, Massachusetts 02141, USA
| | - John J Harrahy
- Amgen Inc, Attribute Science, 360 Binney Street, Cambridge, Massachusetts 02141, USA
| | - Alexander R Ivanov
- Barnett Institute of Chemical and Biological Analysis, Department of Chemistry and Chemical Biology, Northeastern University, 360 Huntington Ave., Boston, Massachusetts 02115, USA.
| |
Collapse
|
14
|
Xu T, Zhang F, Chen D, Sun L, Tomazela D, Fayadat-Dilman L. Interrogating heterogeneity of cysteine-engineered antibody-drug conjugates and antibody-oligonucleotide conjugates by capillary zone electrophoresis-mass spectrometry. MAbs 2023; 15:2229102. [PMID: 37381585 DOI: 10.1080/19420862.2023.2229102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 06/11/2023] [Accepted: 06/20/2023] [Indexed: 06/30/2023] Open
Abstract
Production of site-specific cysteine-engineered antibody-drug conjugates (ADCs) in mammalian cells may produce developability challenges, fragments, and heterogenous molecules, leading to potential product critical quality attributes in later development stages. Liquid phase chromatography with mass spectrometry (LC-MS) is widely used to evaluate antibody impurities and drug-to-antibody ratio, but faces challenges in analysis of fragment product variants of cysteine-engineered ADCs and oligonucleotide-to-antibody ratio (OAR) species of antibody-oligonucleotide conjugates (AOCs). Here, for the first time, we report novel capillary zone electrophoresis (CZE)-MS approaches to address the challenges above. CZE analysis of six ADCs made with different parent monoclonal antibodies (mAbs) and small molecule drug-linker payloads revealed that various fragment impurities, such as half mAbs with one/two drugs, light chains with one/two drugs, light chains with C-terminal cysteine truncation, heavy chain clippings, were well resolved from the main species. However, most of these fragments were coeluted or had signal suppression during LC-MS analysis. Furthermore, the method was optimized on both ionization and separation aspects to enable the characterization of two AOCs. The method successfully achieved baseline separation and accurate quantification of their OAR species, which were also highly challenging using conventional LC-MS methods. Finally, we compared the migration time and CZE separation profiles among ADCs and their parent mAbs, and found that properties of mAbs and linker payloads significantly influenced the separation of product variants by altering their size or charge. Our study showcases the good performance and broad applicability of CZE-MS techniques for monitoring the heterogeneity of cysteine-engineered ADCs and AOCs.
Collapse
Affiliation(s)
- Tian Xu
- Department of Chemistry Michigan State University, East Lansing MI 48824 USA
| | - Fan Zhang
- Discovery Biologics, Protein Sciences, Merck & Co., Inc, South San Francisco, CA 94080 USA
| | - Daoyang Chen
- Discovery Biologics, Protein Sciences, Merck & Co., Inc, South San Francisco, CA 94080 USA
| | - Liangliang Sun
- Department of Chemistry Michigan State University, East Lansing MI 48824 USA
| | - Daniela Tomazela
- Discovery Biologics, Protein Sciences, Merck & Co., Inc, South San Francisco, CA 94080 USA
| | | |
Collapse
|
15
|
Shao X, Huang Y, Wang G. Microfluidic devices for protein analysis using intact and top‐down mass spectrometry. VIEW 2022. [DOI: 10.1002/viw.20220032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Affiliation(s)
- Xinyang Shao
- Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
- Biomedical Pioneering Innovation Center Peking University Beijing China
- Peking‐Tsinghua Center for Life Sciences Peking University Beijing China
| | - Yanyi Huang
- Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
- Biomedical Pioneering Innovation Center Peking University Beijing China
- Peking‐Tsinghua Center for Life Sciences Peking University Beijing China
- College of Chemistry and Molecular Engineering and Beijing National Laboratory for Molecular Sciences Peking University Beijing China
| | - Guanbo Wang
- Institute for Cell Analysis Shenzhen Bay Laboratory Shenzhen China
- Biomedical Pioneering Innovation Center Peking University Beijing China
| |
Collapse
|
16
|
Madren S, Yi L. Microchip electrophoresis separation coupled to mass spectrometry (MCE-MS) for the rapid monitoring of multiple quality attributes of monoclonal antibodies. Electrophoresis 2022; 43:2453-2465. [PMID: 36027045 DOI: 10.1002/elps.202200129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Revised: 08/20/2022] [Accepted: 08/23/2022] [Indexed: 12/14/2022]
Abstract
Therapeutic monoclonal antibodies (mAbs) are highly heterogeneous as a result of posttranslational modifications (PTMs) during bioprocessing and storage. The modifications that impact mAb product quality are regarded as critical quality attributes and require monitoring. The conventional LC-mass spectrometer (MS) method used for product quality monitoring may require protein A purification prior to analysis. In this paper, we present a high-throughput microchip electrophoresis (<4 min) in-line with MS (MCE-MS) that enables baseline separation and characterization of Fc, Fd', and light chain (LC) domains of IdeS-treated mAb sample directly from bioreactor. The NISTmAb was used to optimize the MCE separation and to assess its capability of multiple attribute monitoring. The MCE-MS can uniquely separate and characterize deamidated species at domain level compared to LC-MS method. Two case studies were followed to demonstrate the method capability of monitoring product quality of mAb samples from stability studies or directly from bioreactors.
Collapse
Affiliation(s)
- Seth Madren
- Analytical Development Department, Biogen, Research Triangle Park, Durham, North Carolina, USA
| | - Linda Yi
- Analytical Development Department, Biogen, Research Triangle Park, Durham, North Carolina, USA
| |
Collapse
|
17
|
Wu Z, Wang H, Wu J, Huang Y, Zhao X, Nguyen J, Rosconi M, Pyles EA, Qiu H, Li N. High-Sensitivity and High-Resolution Therapeutic Antibody Charge Variant and Impurity Characterization by Microfluidic Native Capillary Electrophoresis-Mass Spectrometry. J Pharm Biomed Anal 2022; 223:115147. [DOI: 10.1016/j.jpba.2022.115147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 10/22/2022] [Accepted: 11/06/2022] [Indexed: 11/09/2022]
|
18
|
Li W, Chaihu L, Jiang J, Wu B, Zheng X, Dai R, Tian Y, Huang Y, Wang G, Men Y. Microfluidic Platform for Time-Resolved Characterization of Protein Higher-Order Structures and Dynamics Using Top-Down Mass Spectrometry. Anal Chem 2022; 94:7520-7527. [PMID: 35584038 DOI: 10.1021/acs.analchem.2c00077] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Characterization of protein higher-order structures and dynamics is essential for understanding the biological functions of proteins and revealing the underlying mechanisms. Top-down mass spectrometry (MS) accesses structural information at both the intact protein level and the peptide fragment level. Native top-down MS allows analysis of a protein complex's architecture and subunits' identity and modifications. Top-down hydrogen/deuterium exchange (HDX) MS offers high spatial resolution for conformational or binding interface analysis and enables conformer-specific characterization. A microfluidic chip can provide superior performance for front-end reactions useful for these MS workflows, such as flexibility in manipulating multiple reactant flows, integrating various functional modules, and automation. However, most microchip-MS devices are designed for bottom-up approaches or top-down proteomics. Here, we demonstrate a strategy for designing a microchip for top-down MS analysis of protein higher-order structures and dynamics. It is suitable for time-resolved native MS and HDX MS, with designs aiming for efficient ionization of intact protein complexes, flexible manipulation of multiple reactant flows, and precise control of reaction times over a broad range of flow rates on the submicroliter per minute scale. The performance of the prototype device is demonstrated by measurements of systems including monoclonal antibodies, antibody-antigen complexes, and coexisting protein conformers. This strategy may benefit elaborate structural analysis of biomacromolecules and inspire method development using the microchip-MS approach.
Collapse
Affiliation(s)
- Wen Li
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Lingxiao Chaihu
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China.,Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Jialu Jiang
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Bizhu Wu
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Xuan Zheng
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Rongrong Dai
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Ye Tian
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Yanyi Huang
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China.,Biomedical Pioneering Innovation Centre, Peking University, Beijing 100871, China
| | - Guanbo Wang
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China.,Biomedical Pioneering Innovation Centre, Peking University, Beijing 100871, China
| | - Yongfan Men
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
19
|
Candish E, Dykstra A, Polozova A, Ren D, Zhang H. New Aspects in the Integration of MS Technologies in the Biopharmaceutical Industry. LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.sn9080m1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
In the past decade, advances in both separations and mass spectrometry (MS) technologies have enabled new, streamlined, and data-rich approaches to monitor product quality attributes and their relationship with process parameters throughout the lifecycle of therapeutic proteins. As we enter a new decade of technology and method development, MS-based approaches utilized in the biopharmaceutical industry are evolving further. In this mini-review, we explore key developments that could inspire and improve the future of therapeutic protein development.
Collapse
|
20
|
Chen Y, Xia L, Xiao X, Li G. Enhanced capillary zone electrophoresis in cyclic olefin copolymer microchannels using the combination of dynamic and static coatings for rapid analysis of carnosine and niacinamide in cosmetics. J Sep Sci 2022; 45:2045-2054. [PMID: 35324077 DOI: 10.1002/jssc.202101007] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 03/16/2022] [Accepted: 03/18/2022] [Indexed: 11/10/2022]
Abstract
Cosmetics having medicinal effects, including anti-inflammatory and antioxidant, have become a daily care routine consumption. The peptide additives, such as carnosine and nicotinamide, were frequently used to realize these medicinal effects. To accomplish rapid and effective quantitation of carnosine and niacinamide in cosmetics, a capillary zone electrophoresis was executed in cyclic olefin copolymer microchips having both dynamic and static coatings. The static coating of cyclic olefin copolymer microchannel was constructed from bovine albumin adsorption, immobilization and active site closure, while the dynamic coating was formed by adding surfactant into running buffer of capillary zone electrophoresis. The static coating can improve the hydrophilicity of cyclic olefin copolymer surface and avoid nonspecific peptide adsorption. The dynamic coating of sodium dodecyl sulfate in running buffer proved to be useful in flow velocity adjustment and the column efficiency enhancement in capillary zone electrophoresis separation channel of the cyclic olefin copolymer microchip device. A separation resolution up to 4.24 on the mixture of carnosine and nicotinamide was obtained. Moreover, an analysis method was established and applied to simultaneous carnosine and nicotinamide determination in a liquid whitening essence and a solid antiglycation pill and the results were verified by comparison with HPLC methods, indicating its potential in complex sample analysis. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Yali Chen
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China
| | - Ling Xia
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China
| | - Xiaohua Xiao
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou, 510006, China
| |
Collapse
|
21
|
Xu T, Han L, George Thompson AM, Sun L. An improved capillary isoelectric focusing-mass spectrometry method for high-resolution characterization of monoclonal antibody charge variants. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:383-393. [PMID: 34939625 DOI: 10.1039/d1ay01556g] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Routine and high-resolution characterization of monoclonal antibody (mAb) charge variants is vital for controlling mAb quality as therapeutics. Capillary isoelectric focusing-mass spectrometry (cIEF-MS) has emerged as a powerful tool for characterizing mAb charge variants because it can achieve high-resolution separation and highly sensitive detection of proteins. It provides much better identification of charge variants than the traditionally used cIEF-UV method. However, further improvement of cIEF-MS regarding stability and separation resolution is needed. Here, we improved the stability and enhanced separation resolution of automated cIEF-MS by bettering the quality of capillary neutral coating, reducing catholyte pH to 10 for cIEF-MS for the first time, and systematically optimizing the cIEF separation conditions. The improved cIEF-MS method was applied to characterize charge variants of three previously well characterized mAbs (NISTmAb, cetuximab, trastuzumab) and one tool mAb (mAb1). The charge variants of the studied mAbs were well resolved, and the majority of post-translational modifications (PTMs) found in those mAbs agreed with the literature. cIEF-MS analyses of mAb1 were capable of discovering ten charge variants with various interesting PTMs, such as PGK amidation, incomplete C-terminal lysine clipping, glycosylation, and deamination. cIEF-MS was successfully used for accurately determining the isoelectric points (pIs) of mAb1 charge variants via analyzing the pI markers and spiking in a standard protein (cytochrome c) to samples for migration time normalization, which is beneficial for evaluating pI-related pharmacokinetic properties. Our cIEF-MS agreed with and, in some cases (i.e., cetuximab and mAb1), outperformed cIEF-UV for detecting mAb charge variants.
Collapse
Affiliation(s)
- Tian Xu
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| | - Linjie Han
- New Biological Entities (NBE), Analytical R&D, AbbVie Inc., 1 Waukegan Rd, North Chicago, IL, 60064, USA
| | - Alayna M George Thompson
- New Biological Entities (NBE), Analytical R&D, AbbVie Inc., 1 Waukegan Rd, North Chicago, IL, 60064, USA
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, 578 S Shaw Lane, East Lansing, MI 48824, USA.
| |
Collapse
|
22
|
Dai J, Xia Q, Ji C. Capillary Isoelectric Focusing: Mass Spectrometry Method for the Separation and Online Characterization of Monoclonal Antibody Charge Variants at Intact and Subunit Levels. Methods Mol Biol 2022; 2500:55-65. [PMID: 35657587 DOI: 10.1007/978-1-0716-2325-1_6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Monoclonal antibodies (mAbs) are one of the most widely used types of protein therapeutics. Charge variants are important quality attributes for evaluating developability, activity, and safety for mAb therapeutics. Here, we report a novel online capillary isoelectric focusing-mass spectrometry (CIEF-MS) method for mAb charge variant analysis using an electrokinetically pumped sheath-flow nanospray ion source on a time-of-flight (TOF) MS with a pressure-assisted chemical mobilization. Key factors that enable online CIEF-MS include effective capillary electrophoresis-MS (CE-MS) interface with enhanced sensitivity, utilization of MS-friendly electrolytes, beneficial effects of glycerol that reduces non-CIEF electrophoretic mobility and limits band broadening, appropriate ampholyte type and concentration selection for balanced separation resolution and MS detection sensitivity, optimized sheath liquid composition to realize high-resolution CIEF separation and effective MS electrospray ionization, as well as judiciously selected CIEF running parameters. The fundamental premise of CIEF has been verified by the linear correlation between isoelectric point (pI) values and migration time using a mixture of pI markers. By achieving high separation resolutions that are similar as those obtained from imaged CIEF (iCIEF), this method successfully provides highly sensitive MS identification for intact mAb charge variants. Furthermore, a middle-up sample treatment workflow can be adopted to provide in-depth charge variant analysis at subunit level for mAbs with complex charge heterogeneity. The mAb subunit CIEF-MS reveals the source of charge variant with enhanced resolution on both CIEF separation and MS spectra. This novel CIEF-MS method is a valuable tool with distinct advantage for objective and accurate assessment of charge heterogeneity of protein therapeutics.
Collapse
Affiliation(s)
- Jun Dai
- NovaBioAssays LLC, Woburn, MA, USA.
| | | | | |
Collapse
|
23
|
Austin Pickens C, Isenberg SL, Cuthbert C, Petritis K. Combining First and Second-Tier Newborn Screening in a Single Assay Using High-Throughput Chip-Based Capillary Electrophoresis Coupled to High-Resolution Mass Spectrometry. Clin Chem 2021; 67:1709-1720. [PMID: 34606607 DOI: 10.1093/clinchem/hvab171] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Accepted: 08/06/2021] [Indexed: 11/13/2022]
Abstract
BACKGROUND Most first-tier newborn screening (NBS) biomarkers are evaluated by a 2-min flow injection analysis coupled to tandem mass spectrometry (FIA-MS/MS) assay. The absence of separation prior to MS/MS analysis can lead to false positives and inconclusive results due to interferences by nominal isobars and isomers. Therefore, many presumptive positive specimens require confirmation by a higher specificity second-tier assay employing separations, which require additional time and resources prior to patient follow-up. METHODS A 3.2-mm punch was taken from dried blood spot (DBS) specimens and extracted using a solution containing isotopically labeled internal standards for quantification. Analyses were carried out in positive mode using a commercially available microfluidic capillary electrophoresis (CE) system coupled to a high-resolution mass spectrometer (HRMS). RESULTS The CE-HRMS platform quantified 35 first- and second-tier biomarkers from a single injection in <2-min acquisition time, thus, successfully multiplexing first- and second-tier NBS for over 20 disorders in a single DBS punch. The CE-HRMS platform resolved problematic isobars and isomers that affect first-tier FIA-MS/MS assay specificity, while achieving similar quantitative results and assay linearity. CONCLUSIONS Our CE-HRMS assay is capable of multiplexing first- and second-tier NBS biomarkers into a single assay with an acquisition time of <2 min. Such an assay would reduce the volume of false positives and inconclusive specimens flagged for second-tier screening.
Collapse
Affiliation(s)
- C Austin Pickens
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Chamblee, GA, USA
| | - Samantha L Isenberg
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Chamblee, GA, USA
| | - Carla Cuthbert
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Chamblee, GA, USA
| | - Konstantinos Petritis
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Chamblee, GA, USA
| |
Collapse
|
24
|
Kumar R, Guttman A, Rathore AS. Applications of capillary electrophoresis for biopharmaceutical product characterization. Electrophoresis 2021; 43:143-166. [PMID: 34591322 DOI: 10.1002/elps.202100182] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/07/2021] [Accepted: 09/23/2021] [Indexed: 12/16/2022]
Abstract
Capillary electrophoresis (CE), after being introduced several decades ago, has carved out a niche for itself in the field of analytical characterization of biopharmaceutical products. It does not only offer fast separation, high resolution in miniaturized format, but equally importantly represents an orthogonal separation mechanism to high-performance liquid chromatography. Therefore, it is not surprising that CE-based methods can be found in all major pharmacopoeias and are recommended for the analysis of biopharmaceutical products during process development, characterization, quality control, and release testing. Different separation formats of CE, such as capillary gel electrophoresis, capillary isoelectric focusing, and capillary zone electrophoresis are widely used for size and charge heterogeneity characterization as well as purity and stability testing of therapeutic proteins. Hyphenation of CE with MS is emerging as a promising bioanalytical tool to assess the primary structure of therapeutic proteins along with any impurities. In this review, we confer the latest developments in capillary electrophoresis, used for the characterization of critical quality attributes of biopharmaceutical products covering the past 6 years (2015-2021). Monoclonal antibodies, due to their significant share in the market, have been given prioritized coverage.
Collapse
Affiliation(s)
- Ramesh Kumar
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, India
| | - Andras Guttman
- Horváth Csaba Memorial Laboratories of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.,Translational Glycomics Group, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, Veszprem, Hungary
| | - Anurag S Rathore
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, India
| |
Collapse
|
25
|
Kaya SI, Cetinkaya A, Caglayan MG, Ozkan SA. Recent biopharmaceutical applications of capillary electrophoresis methods on recombinant DNA technology-based products. Electrophoresis 2021; 43:1035-1049. [PMID: 34529858 DOI: 10.1002/elps.202100193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/17/2021] [Accepted: 09/05/2021] [Indexed: 11/11/2022]
Abstract
Biopharmaceuticals (recombinant technology-based products, vaccines, whole blood and blood components, gene therapy, cells, tissues, etc.,) are described as biological medical products produced from various living sources such as human, microbial, animal, and so on by manufacturing, extraction, or semi-synthesis. They are complex molecules having high molecular weights. For their safety and efficacy, their structural, clinical, physicochemical, and chemical features must be carefully controlled, and they must be well characterized by analytical techniques before the approval of the final product. Capillary electrophoresis (CE) having versatile modes can provide valuable safety and efficacy information, such as amino acid sequence, size variants (low and high molecular weight variants), charged variants (acidic and basic impurities), aggregates, N-linked glycosylation, and O-linked glycosylation. There are numerous applications of CE in the literature. In this review, the most significant and recent studies on the analysis of recombinant DNA technology-based products using different CE modes in the last ten years have been overviewed. It was seen that the researches mostly focus on the analysis of mAbs and IgG. In addition, in recent years, researchers have started to prefer CE combined mass spectrometry (MS) techniques to provide a more detailed characterization for protein and peptide fragments.
Collapse
Affiliation(s)
- S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Mehmet G Caglayan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
26
|
Dykstra AB, Flick TG, Lee B, Blue LE, Angell N. Chip-Based Capillary Zone Electrophoresis Mass Spectrometry for Rapid Resolution and Quantitation of Critical Quality Attributes in Protein Biotherapeutics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1952-1963. [PMID: 33730487 DOI: 10.1021/jasms.0c00424] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The aspiration of the multi-attribute method (MAM) is to utilize a single mass spectrometry-based method that can measure multiple attributes simultaneously, thus enabling data-driven decisions more quickly and efficiently. However, challenges associated with identifying and quantitating critical quality attributes such as asparagine deamidation and isoaspartic acid using conventional ultrahigh-pressure liquid chromatography (UHPLC) coupled to mass spectrometry have necessitated long gradients to ensure sufficient separation for quantitation. Microfluidic chip-based capillary zone electrophoresis mass spectrometry (CZE-MS) shows potential to enable rapid charge-based separation of peptide mixtures, and this approach was evaluated using multipeptide mixtures of synthetic peptides as well as digested protein therapeutics. In these experiments, repeatability, linearity, and peak-to-peak resolution of several peptide families containing asparagine deamidation and/or isoaspartic acid were demonstrated. In addition, a comparison of peptide map results acquired with both UHPLC-MS and CZE-MS for two enzymatically digested biological therapeutics showed comparable sequence coverage and quantitation results between the two approaches. As MAM becomes increasingly utilized for analysis of biological therapeutics, MS instrument demand will rapidly increase, resulting in a bottleneck. A CZE-based separation shows potential to alleviate this bottleneck by drastically increasing MAM throughput while providing results comparable to those acquired using conventional UHPLC separations.
Collapse
Affiliation(s)
- Andrew B Dykstra
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Tawnya G Flick
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Burton Lee
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Laura E Blue
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Nic Angell
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| |
Collapse
|
27
|
Cao L, Fabry D, Lan K. Rapid and comprehensive monoclonal antibody Characterization using microfluidic CE-MS. J Pharm Biomed Anal 2021; 204:114251. [PMID: 34265486 DOI: 10.1016/j.jpba.2021.114251] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 06/29/2021] [Accepted: 07/01/2021] [Indexed: 10/20/2022]
Abstract
The identification and control of monoclonal antibody (mAb) critical quality attributes (CQAs) is a key component of quality by design (QbD). In this work, rapid peptide mapping and native intact charge variants analysis have been developed to comprehensively characterize and monitor mAb CQAs using a microfluidic capillary electrophoresis - mass spectrometry (CE-MS) platform. The ultrafast peptide mapping simultaneously analyzed multiple CQAs, including protein primary structure, oxidation, deamidation, succinimide, C-terminal lysine (Lys) clipping, N-terminal cyclization, and glycosylation. The microfluidic CE-MS based peptide mapping acquired results comparable to conventional but lengthy liquid chromatography - MS (LC-MS) based approach. The native intact analysis resolved mAb charge variants with a comparable resolution as commonly achieved using capillary isoelectric focusing (cIEF). Charge variants' identities were assigned based on characteristic mass shifts, knowledge learned from peptide mapping, and changes in electrophoretic mobility. Major mAb glycoforms of each charge variants were resolved and identified in the deconvoluted mass spectra. Furthermore, a model simulation was performed to reconstruct intact deconvoluted mass spectra using peptide mapping results. The reconstructed and experimentally determined intact deconvoluted mass spectra were highly correlated, suggesting that our data collected at the peptide level and intact level were consistent and highly comparable. Overall, the microfluidic CE-MS based peptide mapping and native intact charge variants analysis are high-throughput methods that have great potential to support biopharmaceutical development.
Collapse
Affiliation(s)
- Li Cao
- CMC Analytical, GlaxoSmithKline, 1250 S. Collegeville Road, UP 1400, Collegeville, PA, 19426, USA.
| | - Daniel Fabry
- CMC Analytical, GlaxoSmithKline, 1250 S. Collegeville Road, UP 1400, Collegeville, PA, 19426, USA
| | - Kevin Lan
- CMC Analytical, GlaxoSmithKline, 1250 S. Collegeville Road, UP 1400, Collegeville, PA, 19426, USA
| |
Collapse
|
28
|
Ribeiro da Silva M, Zaborowska I, Carillo S, Bones J. A rapid, simple and sensitive microfluidic chip electrophoresis mass spectrometry method for monitoring amino acids in cell culture media. J Chromatogr A 2021; 1651:462336. [PMID: 34153732 DOI: 10.1016/j.chroma.2021.462336] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 06/01/2021] [Accepted: 06/04/2021] [Indexed: 10/21/2022]
Abstract
The development and optimization of cell culture media for biotech applications is a fundamental step of process development. The composition of cell culture media requires an ideal blend of amino acids, vitamins, nucleosides, lipids, carbohydrates, trace elements and other components. The ability to monitor these constituents is required to ensure that cells receive sufficient nutrients to facilitate growth, viability and productivity. Analysis of cell culture media is challenging due to the range and diversity of compounds contained in this matrix and normally requires time consuming methods. A rapid, simple and sensitive microfluidic chip CE-MS method is described to monitor amino acids in chemically defined cell culture media from a Chinese hamster ovary cell line cultured over a period of 10 days. The described platform enabled the separation of 16 amino acids in less than 2 minutes and without the requirement for extensive sample preparation. The analytical parameters evaluated were precision, linearity, limit of detection and limit of quantification. The majority of essential amino acids were present in cell culture growth in high concentrations compared to non-essential amino acids. Over the course of the 10 days cell culture the concentration of certain amino acids declined by up to 100%. Microfluidic chip based CE-MS methods can be used effectively to obtain the consumption rates of amino acids in cell culture media during cell growth and to perform at-line monitoring and screening of cell culture status.
Collapse
Affiliation(s)
| | - Izabela Zaborowska
- NIBRT - National Institute for Bioprocessing Research and Training, Dublin, Ireland
| | - Sara Carillo
- NIBRT - National Institute for Bioprocessing Research and Training, Dublin, Ireland
| | - Jonathan Bones
- NIBRT - National Institute for Bioprocessing Research and Training, Dublin, Ireland; School of Chemical and Bioprocess Engineering, University College Dublin, Dublin 4, Ireland.
| |
Collapse
|
29
|
Ma F, Raoufi F, Bailly MA, Fayadat-Dilman L, Tomazela D. Hyphenation of strong cation exchange chromatography to native mass spectrometry for high throughput online characterization of charge heterogeneity of therapeutic monoclonal antibodies. MAbs 2021; 12:1763762. [PMID: 32370592 PMCID: PMC7299211 DOI: 10.1080/19420862.2020.1763762] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Characterization of charge heterogeneity in monoclonal antibodies (mAbs) is needed during developability assessment and downstream development of drug candidates. Charge heterogeneity can come from post-translational modifications like deamidation, isomerization, and sialylation. Elucidation of charge variants with mass spectrometry (MS) has historically been challenging. Due to the nonvolatility and high ionic strength of conventional buffer systems, labor-intensive offline fractionation followed by MS analysis is routinely used. Here, we describe an alternative strategy that directly couples strong cation exchange (SCX) chromatography to high-resolution Orbitrap MS for online native MS analysis (SCX-MS). A combined pH and salt gradient was used for universal separation of mAbs from a wide range of pI values (6.38 ~ 9.2), including infliximab (Remicade®, chimeric IgG1/kappa), NISTmab (humanized IgG1/kappa) and trastuzumab (Herceptin®, humanized IgG1/kappa), without tailoring of chromatographic profiles. Liquid chromatography and MS parameters were optimized to achieve high-quality spectra and enhanced detection of low abundant species under high flow rate conditions. Genedata Expressionist, a vendor agnostic software, was used for data processing. This integrated strategy allows unbiased characterization of numerous charge variant species and low molecular weight fragments (<0.05%) without post-column flow splitting. The application was further expanded with middle-up approaches for subdomain analysis, which demonstrated the versatility of the strategy for analysis of various construct types. With our analysis of mAbs during developability assessment and forced degradation studies, which aimed at assessing potential critical quality attributes in antibody drug molecules, we provide, for the first time, direct visualization of molecular alterations of mAbs at intact level. Furthermore, strong correlation was observed between this novel MS approach and analysis by capillary isoelectric focusing.
Collapse
Affiliation(s)
- Fengfei Ma
- Protein Sciences, Discovery Biologics, Merck & Co., Inc., South San Francisco, CA, USA
| | - Fahimeh Raoufi
- Protein Sciences, Discovery Biologics, Merck & Co., Inc., South San Francisco, CA, USA
| | - Marc Andre Bailly
- Protein Sciences, Discovery Biologics, Merck & Co., Inc., South San Francisco, CA, USA
| | | | - Daniela Tomazela
- Protein Sciences, Discovery Biologics, Merck & Co., Inc., South San Francisco, CA, USA
| |
Collapse
|
30
|
He S, Joseph N, Feng S, Jellicoe M, Raston CL. Application of microfluidic technology in food processing. Food Funct 2021; 11:5726-5737. [PMID: 32584365 DOI: 10.1039/d0fo01278e] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Microfluidic technology is interdisciplinary with a diversity of applications including in food processing. The rapidly growing global population demands more advanced technologies in food processing to produce more functional and safer food, and for such processing microfluidic devices are a popular choice. This review critically critiques the state-of-the-art designs of microfluidic devices and their applications in food processing, and identifies the key research trends and future research directions for maximizing the value of microfluidic technology. Capillary, planar, and terrace droplet generation systems are currently used in the design of microfluidic devices, each with their strengths and weaknesses as applied in food processing, for emulsification, food safety measurements, and bioactive compound extraction. Conventional channel-based microfluidic devices are prone to clogging, and have high labor costs and low productivity, and their "directional pressure" restricts scaling-up capabilities. These disadvantages can be overcome by using "inside-out centrifugal force" and the new generation continuous flow thin-film microfluidic Vortex Fluidic Device (VFD) which facilitates translating laboratory processing into commercial products. Also highlighted is controlling protein-polysaccharide interactions and the applications of the produced ingredients in food formulations as targets for future development in the field.
Collapse
Affiliation(s)
- Shan He
- Department of Food Science, School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou, Guangdong 510006, China. and Flinders Institute for Nanoscale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park, South Australia, 5042, Australia.
| | - Nikita Joseph
- Flinders Institute for Nanoscale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park, South Australia, 5042, Australia.
| | - Shilun Feng
- School of Electrical and Electronic Engineering, Nanyang Technological University, 639798, Singapore
| | - Matt Jellicoe
- Flinders Institute for Nanoscale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park, South Australia, 5042, Australia.
| | - Colin L Raston
- Flinders Institute for Nanoscale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park, South Australia, 5042, Australia.
| |
Collapse
|
31
|
Cheng M, Shu H, Peng Y, Feng X, Yan G, Zhang L, Yao J, Bao H, Lu H. Specific Analysis of α-2,3-Sialylated N-Glycan Linkage Isomers by Microchip Capillary Electrophoresis-Mass Spectrometry. Anal Chem 2021; 93:5537-5546. [PMID: 33752328 DOI: 10.1021/acs.analchem.1c00064] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Sialylated N-glycan isomers with α-2,3 and α-2,6 linkages play crucial and distinctive roles in diverse physiological and pathological processes. Changes of α-2,3-linked sialic acids in sialylated N-glycans are especially important in monitoring the initiation and progression of diseases. However, the specific analysis of α-2,3-sialylated N-glycan linkage isomers remains challenging due to their extremely low abundance and technical limitations in separation and detection. Herein, we designed an integrated strategy that combines linkage-specific derivatization and a charge-sensitive separation method based on microfluidic chip capillary electrophoresis-mass spectrometry (microchip CE-MS) for specific analysis of α-2,3-sialylated N-glycan linkage isomers for the first time. The α-2,6- and α-2,3-sialic acids were selectively labeled with methylamine (MA) and N,N-dimethylethylenediamine (DMEN), respectively, which selectively makes α-2,3-sialylated N-glycans positively charged and realizes online purification, concentration, and discrimination of α-2,3-sialylated N-glycans from other N-glycans in microchip CE-MS. This new approach was demonstrated with standard multisialylated N-glycans, and it was found that only the α-2,3-sialylated N-glycans migrated and were detected in order according to the number of α-2,3-sialic acids. Finally, this strategy was successfully applied in highly sensitive profiling and reproducible quantitation of the serum α-2,3-sialylated N-glycome from ovarian cancer (OC) patients, where 7 of 33 detected α-2,3-sialylated N-glycans significantly changed in the OC group compared with healthy controls.
Collapse
Affiliation(s)
- Mengxia Cheng
- Department of Chemistry and Shanghai Cancer Center, Fudan University, Shanghai 200032, People's Republic of China.,Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| | - Hong Shu
- Department of Clinical Laboratory, Affiliated Tumor Hospital of Guangxi Medical University, Nanning 530021, People's Republic of China
| | - Ye Peng
- Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| | - Xiaoxiao Feng
- Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| | - Guoquan Yan
- Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| | - Lei Zhang
- Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| | - Jun Yao
- Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| | - Huimin Bao
- Department of Chemistry and Shanghai Cancer Center, Fudan University, Shanghai 200032, People's Republic of China
| | - Haojie Lu
- Department of Chemistry and Shanghai Cancer Center, Fudan University, Shanghai 200032, People's Republic of China.,Institutes of Biomedical Sciences and NHC Key Laboratory of Glycoconjugates Research, Fudan University, Shanghai 200032, People's Republic of China
| |
Collapse
|
32
|
Shen X, Liang Z, Xu T, Yang Z, Wang Q, Chen D, Pham L, Du W, Sun L. Investigating native capillary zone electrophoresis-mass spectrometry on a high-end quadrupole-time-of-flight mass spectrometer for the characterization of monoclonal antibodies. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2021; 462:116541. [PMID: 33642939 PMCID: PMC7906288 DOI: 10.1016/j.ijms.2021.116541] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Native capillary zone electrophoresis-mass spectrometry (CZE-MS) has attracted attentions for the characterization of monoclonal antibodies (mAbs) due to the potential of CZE for highly efficient separations of mAbs under native conditions as well as its compatibility with native electrospray ionization (ESI)-MS. However, the low sample loading capacity and limited separation resolution of native CZE for large proteins and protein complexes (e.g. mAbs) impede the widespread adoption of native CZE-MS. Here, we present a novel native capillary isoelectric focusing (cIEF)-assisted CZE-MS method for the characterization of mAbs with much larger sample loading capacity and significantly better separation resolution than native CZE-MS alone. The native cIEF-assisted CZE-MS employed separation capillaries with a new carbohydrate-based neutral coating, a commercilized electrokinetically pumped sheathflow CE-MS interface, and a high-end quadrupole-time-of-flight (Q-TOF) mass spectrometer. Using the method, we documented the separations of different proteoforms of the SigmaMAb and the detection of its various glyco-proteoforms and homodimer. The native cIEF-assisted CZE-MS separated the NIST mAb into three peaks with a submicroliter sample loading volume, corresponding to its different proteoforms. We observed that both the NIST mAb and its homodimer had eight glyco-proteoforms, four of which had low abundance. The results demonstrate the potential of our native cIEF-assisted CZE-MS method for advancing the characterization of large proteins and protein complexes under native conditions.
Collapse
Affiliation(s)
- Xiaojing Shen
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Zhijie Liang
- Department of Chemistry and Biochemistry, Central Michigan University, Mount Pleasant, MI, USA 48859
- Current address: Department of Wound Repair Surgery, The Fifth Affiliated Hospital of Guangxi Medical University & The First People’s Hospital of Nanning, Nanning, China 530000
| | - Tian Xu
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Zhichang Yang
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Qianjie Wang
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Daoyang Chen
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Lucynda Pham
- Department of Chemistry and Biochemistry, Central Michigan University, Mount Pleasant, MI, USA 48859
| | - Wenjun Du
- Department of Chemistry and Biochemistry, Central Michigan University, Mount Pleasant, MI, USA 48859
- Science of Advanced Materials, Central Michigan University, Mount Pleasant, MI, USA 48859
- Corresponding authors. Wenjun Du: ; Phone: 1-989-774-7568, Liangliang Sun: ; Phone: 1-517-353-0498
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
- Corresponding authors. Wenjun Du: ; Phone: 1-989-774-7568, Liangliang Sun: ; Phone: 1-517-353-0498
| |
Collapse
|
33
|
Towards structure-focused glycoproteomics. Biochem Soc Trans 2021; 49:161-186. [PMID: 33439247 PMCID: PMC7925015 DOI: 10.1042/bst20200222] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 12/07/2020] [Accepted: 12/11/2020] [Indexed: 02/06/2023]
Abstract
Facilitated by advances in the separation sciences, mass spectrometry and informatics, glycoproteomics, the analysis of intact glycopeptides at scale, has recently matured enabling new insights into the complex glycoproteome. While diverse quantitative glycoproteomics strategies capable of mapping monosaccharide compositions of N- and O-linked glycans to discrete sites of proteins within complex biological mixtures with considerable sensitivity, quantitative accuracy and coverage have become available, developments supporting the advancement of structure-focused glycoproteomics, a recognised frontier in the field, have emerged. Technologies capable of providing site-specific information of the glycan fine structures in a glycoproteome-wide context are indeed necessary to address many pending questions in glycobiology. In this review, we firstly survey the latest glycoproteomics studies published in 2018–2020, their approaches and their findings, and then summarise important technological innovations in structure-focused glycoproteomics. Our review illustrates that while the O-glycoproteome remains comparably under-explored despite the emergence of new O-glycan-selective mucinases and other innovative tools aiding O-glycoproteome profiling, quantitative glycoproteomics is increasingly used to profile the N-glycoproteome to tackle diverse biological questions. Excitingly, new strategies compatible with structure-focused glycoproteomics including novel chemoenzymatic labelling, enrichment, separation, and mass spectrometry-based detection methods are rapidly emerging revealing glycan fine structural details including bisecting GlcNAcylation, core and antenna fucosylation, and sialyl-linkage information with protein site resolution. Glycoproteomics has clearly become a mainstay within the glycosciences that continues to reach a broader community. It transpires that structure-focused glycoproteomics holds a considerable potential to aid our understanding of systems glycobiology and unlock secrets of the glycoproteome in the immediate future.
Collapse
|
34
|
Analysis of Monoclonal Antibodies by Capillary Electrophoresis: Sample Preparation, Separation, and Detection. SEPARATIONS 2021. [DOI: 10.3390/separations8010004] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Therapeutic monoclonal antibodies (mAbs) are dominating the biopharmaceutical field due to the fact of their high specificity in the treatment of diverse diseases. Nevertheless, mAbs are very complex glycoproteins exhibiting several macro- and microheterogeneities that may affect their safety, quality, and efficacy. This complexity is very challenging for mAbs development, formulation, and quality control. To tackle the quality issue, a combination of multiple analytical approaches is necessary. In this perspective, capillary electrophoresis has gained considerable interest over the last decade due to the fact of its complementary features to chromatographic approaches. This review provides an overview of the strategies of mAbs and derivatives analysis by capillary electrophoresis hyphenated to ultraviolet, fluorescence, and mass spectrometry detection. The main sample preparation approaches used for mAb analytical characterization (i.e., intact, middle-up/down, and bottom-up) are detailed. The different electrophoretic modes used as well as integrated analysis approaches (sample preparation and separation) are critically discussed.
Collapse
|
35
|
Habazin S, Štambuk J, Šimunović J, Keser T, Razdorov G, Novokmet M. Mass Spectrometry-Based Methods for Immunoglobulin G N-Glycosylation Analysis. EXPERIENTIA SUPPLEMENTUM (2012) 2021; 112:73-135. [PMID: 34687008 DOI: 10.1007/978-3-030-76912-3_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Mass spectrometry and its hyphenated techniques enabled by the improvements in liquid chromatography, capillary electrophoresis, novel ionization, and fragmentation modes are truly a cornerstone of robust and reliable protein glycosylation analysis. Boost in immunoglobulin G (IgG) glycan and glycopeptide profiling demands for both applied biomedical and research applications has brought many new advances in the field in terms of technical innovations, sample preparation, improved throughput, and confidence in glycan structural characterization. This chapter summarizes mass spectrometry basics, focusing on IgG and monoclonal antibody N-glycosylation analysis on several complexity levels. Different approaches, including antibody enrichment, glycan release, labeling, and glycopeptide preparation and purification, are covered and illustrated with recent breakthroughs and examples from the literature omitting excessive theoretical frameworks. Finally, selected highly popular methodologies in IgG glycoanalytics such as liquid chromatography-mass spectrometry and matrix-assisted laser desorption ionization are discussed more thoroughly yet in simple terms making this text a practical starting point either for the beginner in the field or an experienced clinician trying to make sense out of the IgG glycomic or glycoproteomic dataset.
Collapse
Affiliation(s)
- Siniša Habazin
- Glycoscience Research Laboratory, Genos Ltd., Zagreb, Croatia
| | - Jerko Štambuk
- Glycoscience Research Laboratory, Genos Ltd., Zagreb, Croatia
| | | | - Toma Keser
- Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia
| | | | - Mislav Novokmet
- Glycoscience Research Laboratory, Genos Ltd., Zagreb, Croatia.
| |
Collapse
|
36
|
Svejdal RR, Sticker D, Sønderby C, Kutter JP, Rand KD. Thiol-ene microfluidic chip for fast on-chip sample clean-up, separation and ESI mass spectrometry of peptides and proteins. Anal Chim Acta 2020; 1140:168-177. [DOI: 10.1016/j.aca.2020.09.062] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 09/25/2020] [Accepted: 09/28/2020] [Indexed: 01/13/2023]
|
37
|
Schilling M, Feng P, Sosic Z, Traviglia SL. Development and validation of a platform reduced intact mass method for process monitoring of monoclonal antibody glycosylation during routine manufacturing. Bioengineered 2020; 11:1301-1312. [PMID: 33201770 PMCID: PMC8291849 DOI: 10.1080/21655979.2020.1842651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
Abstract
N-linked glycosylation is a primary source of heterogeneity associated with recombinant monoclonal antibodies and plays a key role in a myriad of drug properties associated with biological function. The glycosylation profile of recombinant monoclonal antibodies is influenced by an array of cell culture inputs which must be carefully controlled in order to engineer the desired glycan distribution. A platform reduced intact mass method applied to monoclonal antibodies has been validated as a quantitative method to monitor the relative mannose-5 level as a surrogate for overall high mannose content in cell culture as a control strategy to ensure product quality and process consistency. The method was shown to be linear, accurate, specific, and precise for an IgG1 and IgG4 mAb allowing relative quantitation of mannose-5 in the range 0.8-11.0% and 1.0-6.2%, respectively. The method can be applied at several stages of the production process from cell culture harvest to drug substance/drug product and is amenable to routine GMP batch testing in a quality control laboratory. Testing upstream during cell culture rather than for product release allows for an earlier assessment of product quality as the glycosylation profile remains unchanged during downstream purification.
Collapse
Affiliation(s)
| | - Pamela Feng
- Analytical Development, Biogen, Inc ., Cambridge, MA, USA
| | - Zoran Sosic
- Analytical Development, Biogen, Inc ., Cambridge, MA, USA
| | | |
Collapse
|
38
|
Hartanto H, Wu M, Lam ML, Chen TH. Microfluidic immunoassay for detection of serological antibodies: A potential tool for rapid evaluation of immunity against SARS-CoV-2. BIOMICROFLUIDICS 2020; 14:061507. [PMID: 33343783 PMCID: PMC7738199 DOI: 10.1063/5.0031521] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 11/23/2020] [Indexed: 05/06/2023]
Abstract
In December 2019, coronavirus disease 2019 became a pandemic affecting more than 200 countries and territories. Millions of lives are still affected because of mandatory quarantines, which hamstring economies and induce panic. Immunology plays a major role in the modern field of medicine, especially against virulent infectious diseases. In this field, neutralizing antibodies are heavily studied because they reflect the level of infection and individuals' immune status, which are essential when considering resumption of work, flight travel, and border entry control. More importantly, it also allows evaluating the antiviral vaccine efficacy as vaccines are still known for being the ultimate intervention method to inhibit the rapid spread of virulent infectious diseases. In this Review, we first introduce the host immune response after the infection of SARS-CoV-2 and discuss the latest results using conventional immunoassays. Next, as an enabling platform for detection with sufficient sensitivity while saving analysis time and sample size, the progress of microfluidic-based immunoassays is discussed and compared based on surface modification, microfluidic kinetics, signal output, signal amplification, sample matrix, and the detection of anti-SARS-CoV-2 antibodies. Based on the overall comparison, this Review concludes by proposing the future integration of visual quantitative signals on microfluidic devices as a more suitable approach for general use and large-scale surveillance.
Collapse
Affiliation(s)
- Hogi Hartanto
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region 999077, China
| | - Minghui Wu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region 999077, China
| | - Miu Ling Lam
- School of Creative Media, City University of Hong Kong, Hong Kong Special Administrative Region 999077, China
| | - Ting-Hsuan Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region 999077, China
- Author to whom correspondence should be addressed:
| |
Collapse
|
39
|
Deyanova EG, Huang RYC, Madia PA, Nandi P, Gudmundsson O, Chen G. Rapid fingerprinting of a highly glycosylated fusion protein by microfluidic chip-based capillary electrophoresis-mass spectrometry. Electrophoresis 2020; 42:460-464. [PMID: 32885501 DOI: 10.1002/elps.202000132] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 08/24/2020] [Accepted: 08/26/2020] [Indexed: 02/04/2023]
Abstract
Protein glycosylation can impact the efficacy, safety, and pharmacokinetics of therapeutic proteins. Achieving uniform and consistent protein glycosylation is an important requirement for product quality control at all stages of therapeutic protein drug discovery and development. The development of a new microfluidic CE device compatible with MS offers a fast and sensitive orthogonal mode of high-resolution separation with MS characterization. Here, we describe a fast and robust chip-based CE-MS method for intact glycosylation fingerprinting of a therapeutic fusion protein with complex sialylated N and O-linked glycoforms. The method effectively separates multiple sialylated glycoforms and offers a rapid detection of changes in glycosylation profile in 6 min.
Collapse
Affiliation(s)
- Ekaterina G Deyanova
- Pharmaceutical Candidate Optimization, Nonclinical Research and Development, Bristol Myers Squibb Company, Princeton, NJ, USA
| | - Richard Y-C Huang
- Pharmaceutical Candidate Optimization, Nonclinical Research and Development, Bristol Myers Squibb Company, Princeton, NJ, USA
| | - Priyanka A Madia
- Pharmaceutical Candidate Optimization, Nonclinical Research and Development, Bristol Myers Squibb Company, Princeton, NJ, USA
| | - Pradyot Nandi
- Pharmaceutical Candidate Optimization, Nonclinical Research and Development, Bristol Myers Squibb Company, Princeton, NJ, USA
| | - Olafur Gudmundsson
- Pharmaceutical Candidate Optimization, Nonclinical Research and Development, Bristol Myers Squibb Company, Princeton, NJ, USA
| | - Guodong Chen
- Pharmaceutical Candidate Optimization, Nonclinical Research and Development, Bristol Myers Squibb Company, Princeton, NJ, USA
| |
Collapse
|
40
|
Carillo S, Jakes C, Bones J. In-depth analysis of monoclonal antibodies using microfluidic capillary electrophoresis and native mass spectrometry. J Pharm Biomed Anal 2020; 185:113218. [DOI: 10.1016/j.jpba.2020.113218] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 02/27/2020] [Accepted: 02/28/2020] [Indexed: 12/22/2022]
|
41
|
Cheng J, Wang L, Rive CM, Holt RA, Morin GB, Chen DDY. Complementary Methods for de Novo Monoclonal Antibody Sequencing to Achieve Complete Sequence Coverage. J Proteome Res 2020; 19:2700-2707. [PMID: 32338916 DOI: 10.1021/acs.jproteome.0c00223] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Mass spectrometry is a powerful tool for de novo sequencing of novel proteins. Recent efforts in this area have mainly focused on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Here, we present an alternative method, capillary electrophoresis tandem mass spectrometry (CE-MS/MS), for sequencing novel monoclonal antibodies. Using less than 200 ng in total of tryptic digest sample in a triplicated measurement, CE-MS/MS with pH-mediated focusing successfully sequenced mAb infliximab with 100% sequence coverage and 100% accuracy for the light chain and 96% coverage and 93% accuracy for the heavy chain. It was also demonstrated that CE-MS/MS gives comparable results, and in some cases, even better results, as compared to LC-MS/MS when used as a standalone technique. A combined workflow using both CE-MS/MS and LC-MS/MS was also used to sequence a novel antibody, anti-CD-176, resulting in the first proposed sequence for this mAb.
Collapse
Affiliation(s)
- Jianhui Cheng
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Lingyu Wang
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| | - Craig M Rive
- Michael Smith Genome Sciences Centre, British Columbia Cancer Agency and Department of Medical Genetics, University of British Columbia, Vancouver, British Columbia V5Z 1L3, Canada
| | - Robert A Holt
- Michael Smith Genome Sciences Centre, British Columbia Cancer Agency and Department of Medical Genetics, University of British Columbia, Vancouver, British Columbia V5Z 1L3, Canada
| | - Gregg B Morin
- Michael Smith Genome Sciences Centre, British Columbia Cancer Agency and Department of Medical Genetics, University of British Columbia, Vancouver, British Columbia V5Z 1L3, Canada
| | - David D Y Chen
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada
| |
Collapse
|
42
|
Abstract
Metabolomics is the comprehensive study of small-molecule metabolites. Obtaining a wide coverage of the metabolome is challenging because of the broad range of physicochemical properties of the small molecules. To study the compounds of interest spectroscopic (NMR), spectrometric (MS) and separation techniques (LC, GC, supercritical fluid chromatography, CE) are used. The choice for a given technique is influenced by the sample matrix, the concentration and properties of the metabolites, and the amount of sample. This review discusses the most commonly used analytical techniques for metabolomic studies, including their advantages, drawbacks and some applications.
Collapse
|
43
|
Combination of intact, middle-up and bottom-up levels to characterize 7 therapeutic monoclonal antibodies by capillary electrophoresis – Mass spectrometry. J Pharm Biomed Anal 2020; 182:113107. [DOI: 10.1016/j.jpba.2020.113107] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 01/08/2020] [Accepted: 01/10/2020] [Indexed: 12/22/2022]
|
44
|
Füssl F, Trappe A, Carillo S, Jakes C, Bones J. Comparative Elucidation of Cetuximab Heterogeneity on the Intact Protein Level by Cation Exchange Chromatography and Capillary Electrophoresis Coupled to Mass Spectrometry. Anal Chem 2020; 92:5431-5438. [PMID: 32105056 DOI: 10.1021/acs.analchem.0c00185] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Charge sensitive separation methods such as ion exchange chromatography (CEX) and capillary electrophoresis (CE) have recently been coupled to mass spectrometry to facilitate high resolution profiling of proteoforms present within the charge variant profile of complex biopharmaceuticals. Here we apply pH gradient cation exchange chromatography and microfluidic capillary electrophoresis using the ZipChip platform for comparative characterization of the monoclonal antibody Cetuximab. Cetuximab harbors four glycans per molecule, two on each heavy chain, of which the Fab glycans have been reported to be complex and multiply sialylated. The presence of these extra glycosylation sites in the variable region of the molecule causes significant charge variant and glycan heterogeneity, which makes comprehensive analysis on the intact protein level challenging. Both pH gradient CEX-MS and CE-MS were found to be powerful for the separation of Cetuximab charge variants with eight major peaks being baseline resolved using both separation platforms. Informative native-like mass spectra were collected for each charge variant peak using both platforms that facilitated deconvolution and further analysis. The total proteoform coverage was exceptionally high with >100 isoforms identified and relatively quantified with CEX-MS, in case of CE-MS the proteoform coverage was >200. A deep insight into the heterogeneity of Cetuximab was unveiled, the high level of sensitivity achievable enables the implementation of the presented technologies even at early stages of the biopharmaceutical development platform, such as in developability assessment, process development and also for monitoring process consistency.
Collapse
Affiliation(s)
- Florian Füssl
- NIBRT - The National Institute for Bioprocessing Research and Training, Foster Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland
| | - Anne Trappe
- NIBRT - The National Institute for Bioprocessing Research and Training, Foster Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland
| | - Sara Carillo
- NIBRT - The National Institute for Bioprocessing Research and Training, Foster Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland
| | - Craig Jakes
- NIBRT - The National Institute for Bioprocessing Research and Training, Foster Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland.,School of Chemical and Bioprocess Engineering, University College Dublin, Belfield, Dublin 4, D04 V1W8, Ireland
| | - Jonathan Bones
- NIBRT - The National Institute for Bioprocessing Research and Training, Foster Avenue, Mount Merrion, Blackrock, Co. Dublin, A94 X099, Ireland.,School of Chemical and Bioprocess Engineering, University College Dublin, Belfield, Dublin 4, D04 V1W8, Ireland
| |
Collapse
|
45
|
Kristoff CJ, Li C, Li P, Holland LA. Low Flow Voltage Free Interface for Capillary Electrophoresis and Mass Spectrometry Driven by Vibrating Sharp-Edge Spray Ionization. Anal Chem 2020; 92:3006-3013. [PMID: 31971372 PMCID: PMC7295075 DOI: 10.1021/acs.analchem.9b03994] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Capillary electrophoresis-mass spectrometry is a powerful technique for high-throughput and high efficiency separations combined with structural identification. Electrospray ionization is the primary interface used to couple capillary electrophoresis to mass analyzers; however, improved designs continue to be reported. A new interfacing method based on vibrating sharp-edge spray ionization is presented in this work to overcome the challenges of decoupling applied voltages and to enhance the compatibility with separations performed at near-neutral pH. The versatility and ease of use of this ionization source is demonstrated using β-blockers, peptides, and proteins. The cationic β-blocker pindolol was injected electrokinetically, and detected at concentrations ranging from 10 nM to 5 μM, with an estimated detection limit of 2 nM. The vibrating sharp-edge spray ionization functions with flow rates from 70 to 200 nL/min and did not perturb the capillary electrophoresis separation electroosmotic flow as evidenced by the observation that most migration times differed less than 7% (n = 3) across a lab-built system interfaced to mass spectrometry and a commercial system that utilizes absorbance detection. For cationic beta-blockers the theoretical plates achieved in the capillary electrophoresis-mass spectrometry setup were 80%-95% of that observed with a commercial capillary electrophoresis-UV absorbance detection system.
Collapse
Affiliation(s)
- Courtney J. Kristoff
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Lisa A. Holland
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| |
Collapse
|
46
|
Dadouch M, Ladner Y, Bich C, Larroque M, Larroque C, Morel J, Bonnet PA, Perrin C. An in-line enzymatic microreactor for the middle-up analysis of monoclonal antibodies by capillary electrophoresis. Analyst 2020; 145:1759-1767. [DOI: 10.1039/c9an01906e] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
In-line enzymatic microreactor and electrophoretic strategy for the middle-up analysis of monoclonal antibodies.
Collapse
Affiliation(s)
- Meriem Dadouch
- Institut des Biomolécules Max Mousseron (IBMM)
- UMR 5247-CNRS-UM-ENSCM
- Université de Montpellier
- Montpellier
- France
| | - Yoann Ladner
- Institut des Biomolécules Max Mousseron (IBMM)
- UMR 5247-CNRS-UM-ENSCM
- Université de Montpellier
- Montpellier
- France
| | - Claudia Bich
- Institut des Biomolécules Max Mousseron (IBMM)
- UMR 5247-CNRS-UM-ENSCM
- Université de Montpellier
- Montpellier
- France
| | - Marion Larroque
- Institut de Recherche en Cancérologie de Montpellier (IRCM)
- INSERM U1194
- Montpellier
- France
| | - Christian Larroque
- Institut de Recherche en Cancérologie de Montpellier (IRCM)
- INSERM U1194
- Montpellier
- France
| | - Jacques Morel
- Département de Rhumatologie
- Université de Montpellier
- Montpellier cedex 5
- France
| | - Pierre-Antoine Bonnet
- Institut des Biomolécules Max Mousseron (IBMM)
- UMR 5247-CNRS-UM-ENSCM
- Université de Montpellier
- Montpellier
- France
| | - Catherine Perrin
- Institut des Biomolécules Max Mousseron (IBMM)
- UMR 5247-CNRS-UM-ENSCM
- Université de Montpellier
- Montpellier
- France
| |
Collapse
|
47
|
Gomes FP, Yates JR. Recent trends of capillary electrophoresis-mass spectrometry in proteomics research. MASS SPECTROMETRY REVIEWS 2019; 38:445-460. [PMID: 31407381 PMCID: PMC6800771 DOI: 10.1002/mas.21599] [Citation(s) in RCA: 61] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Progress in proteomics research has led to a demand for powerful analytical tools with high separation efficiency and sensitivity for confident identification and quantification of proteins, posttranslational modifications, and protein complexes expressed in cells and tissues. This demand has significantly increased interest in capillary electrophoresis-mass spectrometry (CE-MS) in the past few years. This review provides highlights of recent advances in CE-MS for proteomics research, including a short introduction to top-down mass spectrometry and native mass spectrometry (native MS), as well as a detailed overview of CE methods. Both the potential and limitations of these methods for the analysis of proteins and peptides in synthetic and biological samples and the challenges of CE methods are discussed, along with perspectives about the future direction of CE-MS. @ 2019 Wiley Periodicals, Inc. Mass Spec Rev 00:1-16, 2019.
Collapse
Affiliation(s)
| | - John R. Yates
- Correspondent author: , Phone number: (858) 784-8862, Departments of Molecular Medicine and Neurobiology, 10550 North Torrey Pines Road, SR302B, The Scripps Research Institute, La Jolla, CA 92037
| |
Collapse
|
48
|
Camperi J, Pichon V, Delaunay N. Separation methods hyphenated to mass spectrometry for the characterization of the protein glycosylation at the intact level. J Pharm Biomed Anal 2019; 178:112921. [PMID: 31671335 DOI: 10.1016/j.jpba.2019.112921] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 10/07/2019] [Accepted: 10/09/2019] [Indexed: 01/26/2023]
Abstract
Glycosylation is one of the most common post-translational modifications of proteins that affects their biological activity, solubility, and half-life. Therefore, its characterization is of great interest in proteomic, particularly from a diagnostic and therapeutic point of view. However, the number and type of glycosylation sites, the degree of site occupancy and the different possible structures of glycans can lead to a very large number of isoforms for a given protein, called glycoforms. The identification of these glycoforms constitutes an important analytical challenge. Indeed, to attempt to characterize all of them, it is necessary to develop efficient separation methods associated with a sensitive and informative detection mode, such as mass spectrometry (MS). Most analytical methods are based on bottom-up proteomics, which consists in the analysis of the protein at the glycopeptides level after its digestion. Even if this approach provides essential information, including the localization and composition of glycans on the protein, it is also characterized by a loss of information on macro-heterogeneity, i.e. the nature of the glycans present on a given glycoform. The analysis of glycoforms at the intact level can overcome this disadvantage. The aim of this review is to detail the state-of-the art of separation methods that can be easily hyphenated with MS for the characterization of protein glycosylation at the intact level. The different electrophoretic and chromatographic approaches are discussed in detail. The miniaturization of these separation methods is also discussed with their potential applications. While the first studies focused on the development and optimization of the separation step to achieve high resolution between isoforms, the recent ones are much more application-oriented, such as clinical diagnosis, quality control, and glycoprotein monitoring in formulations or biological samples.
Collapse
Affiliation(s)
- Julien Camperi
- Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, UMR CBI 8231 CNRS - ESPCI Paris, PSL University, Paris, France
| | - Valerie Pichon
- Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, UMR CBI 8231 CNRS - ESPCI Paris, PSL University, Paris, France; Sorbonne Université, Paris, France
| | - Nathalie Delaunay
- Laboratory of Analytical, Bioanalytical Sciences and Miniaturization, UMR CBI 8231 CNRS - ESPCI Paris, PSL University, Paris, France.
| |
Collapse
|
49
|
Füssl F, Criscuolo A, Cook K, Scheffler K, Bones J. Cracking Proteoform Complexity of Ovalbumin with Anion-Exchange Chromatography–High-Resolution Mass Spectrometry under Native Conditions. J Proteome Res 2019; 18:3689-3702. [DOI: 10.1021/acs.jproteome.9b00375] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Florian Füssl
- NIBRT—The National Institute for Bioprocessing Research and Training, Foster Avenue,
Mount Merrion, Blackrock, Co. Dublin A94 X099, Ireland
| | - Angela Criscuolo
- Thermo Fisher Scientific, Hanna-Kunath-Strasse 11, 28199 Bremen, Germany
| | - Ken Cook
- Thermo Fisher Scientific, Stafford House, 1 Boundary Park, Hemel Hempstead HP2 7GE, United Kingdom
| | - Kai Scheffler
- Thermo Fisher Scientific, Dornierstrasse 4, 82110 Germering, Germany
| | - Jonathan Bones
- NIBRT—The National Institute for Bioprocessing Research and Training, Foster Avenue,
Mount Merrion, Blackrock, Co. Dublin A94 X099, Ireland
- School of Chemical and Bioprocess Engineering, University College Dublin, Belfield, Dublin 4 D04 V1W8, Ireland
| |
Collapse
|
50
|
Le-Minh V, Tran N, Makky A, Rosilio V, Taverna M, Smadja C. Capillary zone electrophoresis-native mass spectrometry for the quality control of intact therapeutic monoclonal antibodies. J Chromatogr A 2019; 1601:375-384. [DOI: 10.1016/j.chroma.2019.05.050] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 05/18/2019] [Accepted: 05/26/2019] [Indexed: 01/27/2023]
|