1
|
Slusher GA, Kottke PA, Culberson AL, Chilmonczyk MA, Fedorov AG. Microfluidics enabled multi-omics triple-shot mass spectrometry for cell-based therapies. BIOMICROFLUIDICS 2024; 18:011302. [PMID: 38268742 PMCID: PMC10807926 DOI: 10.1063/5.0175178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 01/01/2024] [Indexed: 01/26/2024]
Abstract
In recent years, cell-based therapies have transformed medical treatment. These therapies present a multitude of challenges associated with identifying the mechanism of action, developing accurate safety and potency assays, and achieving low-cost product manufacturing at scale. The complexity of the problem can be attributed to the intricate composition of the therapeutic products: living cells with complex biochemical compositions. Identifying and measuring critical quality attributes (CQAs) that impact therapy success is crucial for both the therapy development and its manufacturing. Unfortunately, current analytical methods and tools for identifying and measuring CQAs are limited in both scope and speed. This Perspective explores the potential for microfluidic-enabled mass spectrometry (MS) systems to comprehensively characterize CQAs for cell-based therapies, focusing on secretome, intracellular metabolome, and surfaceome biomarkers. Powerful microfluidic sampling and processing platforms have been recently presented for the secretome and intracellular metabolome, which could be implemented with MS for fast, locally sampled screening of the cell culture. However, surfaceome analysis remains limited by the lack of rapid isolation and enrichment methods. Developing innovative microfluidic approaches for surface marker analysis and integrating them with secretome and metabolome measurements using a common analytical platform hold the promise of enhancing our understanding of CQAs across all "omes," potentially revolutionizing cell-based therapy development and manufacturing for improved efficacy and patient accessibility.
Collapse
Affiliation(s)
| | - Peter A. Kottke
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30318, USA
| | | | | | | |
Collapse
|
2
|
Li Y, Jia K, Pan Y, Han J, Chen J, Wang Y, Ma X, Chen H, Wang S, Xie D, Xiong C, Nie Z. Pocket-Size Wireless Nanoelectrospray Ionization Mass Spectrometry for Metabolic Analysis of Salty Biofluids and Single Cells. Anal Chem 2023; 95:4612-4618. [PMID: 36862115 DOI: 10.1021/acs.analchem.2c04268] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2023]
Abstract
Analysis of volume-limited biological samples such as single cells and biofluids not only benefits clinical purposes but also promotes fundamental research in life sciences. Detection of these samples, however, imposes strict requirements on measurement performance because of the minimal volume and concentrated salts of the samples. Herein, we developed a self-cleaning nanoelectrospray ionization device powered by a pocket-size "MasSpec Pointer" (MSP-nanoESI) for metabolic analysis of salty biological samples with limited volume. The self-cleaning effect induced by Maxwell-Wagner electric stress helps with keeping the borosilicate glass capillary tip free from clogging and thus increasing salt tolerance. This device possesses a high sample economy (about 0.1 μL per test) due to its pulsed high voltage supply, sampling method (dipping the nanoESI tip into analyte solution), and contact-free electrospray ionization (ESI) (the electrode does not touch the analyte solution during ESI). High repeatable results could be acquired by the device with a relative standard deviation (RSD) of 1.02% for voltage output and 12.94% for MS signals of caffeine standard. Single MCF-7 cells were metabolically analyzed directly from phosphate buffered saline, and two types of untreated cerebrospinal fluid from hydrocephalus patients were distinguished with 84% accuracy. MSP-nanoESI gets rid of the bulky apparatus and could be held in hand or put into one's pocket for transportation, and it could operate for more than 4 h without recharge. We believe this device will boost scientific research and clinical usage of volume-limited biological samples with high-concentration salts in a low-cost, convenient, and rapid manner.
Collapse
Affiliation(s)
- Yuze Li
- State Key Laboratory of High-efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan 750021, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Ke Jia
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yixin Pan
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jing Han
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Junyu Chen
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yiran Wang
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xiaobing Ma
- Aerospace Information Research Institute, Chinese Academy of Sciences Beijing 100094, China
| | - Hongwei Chen
- Department of Neurosurgery for Cerebrospinal Fluid Diseases, Aviation General Hospital, Beijing 100012, China
| | - Shengjie Wang
- Department of Neurosurgery for Cerebrospinal Fluid Diseases, Aviation General Hospital, Beijing 100012, China
| | - Dongcheng Xie
- Department of Neurosurgery for Cerebrospinal Fluid Diseases, Aviation General Hospital, Beijing 100012, China
| | - Caiqiao Xiong
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Zongxiu Nie
- State Key Laboratory of High-efficiency Utilization of Coal and Green Chemical Engineering, College of Chemistry and Chemical Engineering, Ningxia University, Yinchuan 750021, China.,Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
3
|
Li C, DeVor A, Wang J, Valentine SJ, Li P. Rapid and flexible online desalting using Nafion-coated melamine sponge for mass spectrometry analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9341. [PMID: 35729084 PMCID: PMC9357145 DOI: 10.1002/rcm.9341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 06/17/2022] [Accepted: 06/17/2022] [Indexed: 06/15/2023]
Abstract
RATIONALE The performance of mass spectrometry (MS) analysis is often affected by the presence of salt ions. To achieve optimal MS detection results, desalting is necessary for samples with high salt concentrations. We report a rapid, low-cost and flexible online desalting method using Nafion-coated sponge. This method is easy to perform and can be implemented to a wide range of customized fluidic systems. METHODS Nafion-coated melamine sponge was fabricated by soaking a glass tube containing a melamine sponge in Nafion solution and then drying overnight. The online desalting workflow is comprised of three major parts: (1) Syringe pump, which provides a continuous flow for the online fluid system; (2) Nafion sponge in a glass tube, where the online desalting of sample solution happens; (3) Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI), which is an ionization technique to ionize the desalted analytes. RESULTS Effective online desalting of a 10 mM NaCl solution was demonstrated for a wide range of molecules including small molecules, peptides, DNAs, and proteins using a flow rate of 10 μL/min. By incorporating multiple pieces of the Nafion-coated sponge, effective desalting for ubiquitin and cytochrome c (Cyt-c) from physiological buffers, including phosphate-buffered saline (PBS) and tris-buffered saline (TBS), were also achieved. For molecules that are sensitive to low pH conditions after desalting, a R-SO3 NH4 -type Nafion-coated sponge was fabricated. Desalting of ubiquitin, oligosaccharide, and DNA oligomers from 10 mM NaCl or 10 mM KCl solutions was demonstrated. CONCLUSIONS Flexible, low-cost, and efficient online desalting was achieved by the Nafion-coated sponge. A variety of molecules ranging from small molecules, peptides, proteins to oligosaccharides and DNAs can be desalted for MS analysis. The desalting by Nafion sponge has great potential for desalting applications that require customized fluidic design and rapid analysis.
Collapse
Affiliation(s)
- Chong Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Amanda DeVor
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Jing Wang
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV
| |
Collapse
|
4
|
Chilmonczyk MA, Doron G, Kottke PA, Culberson AL, Leguineche K, Guldberg RE, Horwitz EM, Fedorov AG. Localized Sampling Enables Monitoring of Cell State via Inline Electrospray Ionization Mass Spectrometry. Biotechnol J 2021; 16:e2000277. [PMID: 32975016 PMCID: PMC7940552 DOI: 10.1002/biot.202000277] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 09/09/2020] [Indexed: 12/21/2022]
Abstract
Nascent advanced therapies, including regenerative medicine and cell and gene therapies, rely on the production of cells in bioreactors that are highly heterogeneous in both space and time. Unfortunately, advanced therapies have failed to reach a wide patient population due to unreliable manufacturing processes that result in batch variability and cost prohibitive production. This can be attributed largely to a void in existing process analytical technologies (PATs) capable of characterizing the secreted critical quality attribute (CQA) biomolecules that correlate with the final product quality. The Dynamic Sampling Platform (DSP) is a PAT for cell bioreactor monitoring that can be coupled to a suite of sensor techniques to provide real-time feedback on spatial and temporal CQA content in situ. In this study, DSP is coupled with electrospray ionization mass spectrometry and direct-from-culture sampling to obtain measures of CQA content in bulk media and the cell microenvironment throughout the entire cell culture process (≈3 weeks). Post hoc analysis of this real-time data reveals that sampling from the microenvironment enables cell state monitoring (e.g., confluence, differentiation). These results demonstrate that an effective PAT should incorporate both spatial and temporal resolution to serve as an effective input for feedback control in biomanufacturing.
Collapse
Affiliation(s)
- Mason A. Chilmonczyk
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
- NSF Engineering Research Center (ERC) for Cell Manufacturing Technologies (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| | - Gilad Doron
- NSF Engineering Research Center (ERC) for Cell Manufacturing Technologies (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| | - Peter A. Kottke
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
- NSF Engineering Research Center (ERC) for Cell Manufacturing Technologies (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| | - Austin L. Culberson
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
- NSF Engineering Research Center (ERC) for Cell Manufacturing Technologies (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| | - Kelly Leguineche
- The Phil and Penny Knight Campus for Accelerating Scientific Impact, University of Oregon, Eugene, OR
| | - Robert E. Guldberg
- NSF Engineering Research Center (ERC) for Cell Manufacturing Technologies (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
- The Phil and Penny Knight Campus for Accelerating Scientific Impact, University of Oregon, Eugene, OR
| | | | - Andrei G. Fedorov
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
- NSF Engineering Research Center (ERC) for Cell Manufacturing Technologies (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| |
Collapse
|
5
|
Xu S, Xue J, Bai Y, Liu H. High-Throughput Single-Cell Immunoassay in the Cellular Native Environment Using Online Desalting Dual-Spray Mass Spectrometry. Anal Chem 2020; 92:15854-15861. [DOI: 10.1021/acs.analchem.0c03167] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Shuting Xu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Jinjuan Xue
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Yu Bai
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| |
Collapse
|
6
|
Arter WE, Xu CK, Castellana-Cruz M, Herling TW, Krainer G, Saar KL, Kumita JR, Dobson CM, Knowles TPJ. Rapid Structural, Kinetic, and Immunochemical Analysis of Alpha-Synuclein Oligomers in Solution. NANO LETTERS 2020; 20:8163-8169. [PMID: 33079553 PMCID: PMC7116857 DOI: 10.1021/acs.nanolett.0c03260] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Oligomers comprised of misfolded proteins are implicated as neurotoxins in the pathogenesis of protein misfolding conditions such as Parkinson's and Alzheimer's diseases. Structural, biophysical, and biochemical characterization of these nanoscale protein assemblies is key to understanding their pathology and the design of therapeutic interventions, yet it is challenging due to their heterogeneous, transient nature and low relative abundance in complex mixtures. Here, we demonstrate separation of heterogeneous populations of oligomeric α-synuclein, a protein central to the pathology of Parkinson's disease, in solution using microfluidic free-flow electrophoresis. We characterize nanoscale structural heterogeneity of transient oligomers on a time scale of seconds, at least 2 orders of magnitude faster than conventional techniques. Furthermore, we utilize our platform to analyze oligomer ζ-potential and probe the immunochemistry of wild-type α-synuclein oligomers. Our findings contribute to an improved characterization of α-synuclein oligomers and demonstrate the application of microchip electrophoresis for the free-solution analysis of biological nanoparticle analytes.
Collapse
Affiliation(s)
- William E. Arter
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
- Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
| | - Catherine K. Xu
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Marta Castellana-Cruz
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Therese W. Herling
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Georg Krainer
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Kadi L. Saar
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Janet R. Kumita
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Christopher M. Dobson
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
| | - Tuomas P. J. Knowles
- Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW UK
- Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue, Cambridge CB3 0HE, UK
| |
Collapse
|
7
|
Li G, Ma F, Cao Q, Zheng Z, DeLaney K, Liu R, Li L. Nanosecond photochemically promoted click chemistry for enhanced neuropeptide visualization and rapid protein labeling. Nat Commun 2019; 10:4697. [PMID: 31619683 PMCID: PMC6795811 DOI: 10.1038/s41467-019-12548-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Accepted: 09/17/2019] [Indexed: 12/28/2022] Open
Abstract
Comprehensive protein identification and concomitant structural probing of proteins are of great biological significance. However, this is challenging to accomplish simultaneously in one confined space. Here, we develop a nanosecond photochemical reaction (nsPCR)-based click chemistry, capable of structural probing of proteins and enhancing their identifications through on-demand removal of surrounding matrices within nanoseconds. The nsPCR is initiated using a photoactive compound, 2-nitrobenzaldehyde (NBA), and is examined by matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS). Benefiting from the on-demand matrix-removal effect, this nsPCR strategy enables enhanced neuropeptide identification and visualization from complex tissue samples such as mouse brain tissue. The design shows great promise for structural probing of proteins up to 155 kDa due to the exclusive accessibility of nsPCR to primary amine groups, as demonstrated by its general applicability using a series of proteins with various lysine residues from multiple sample sources, with accumulated labeling efficiencies greater than 90%. Mass spectrometry-based quantitative proteomics aim to identify and quantify proteins from complex biological samples. Here, the authors developed a method for simultaneous high-throughput protein labelling and on-demand matrix removal within nanoseconds.
Collapse
Affiliation(s)
- Gongyu Li
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Fengfei Ma
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Qinjingwen Cao
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Zhen Zheng
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Kellen DeLaney
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Rui Liu
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Lingjun Li
- School of Pharmacy, University of Wisconsin-Madison, Madison, WI, 53705, USA. .,Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53705, USA.
| |
Collapse
|
8
|
Chilmonczyk MA, Kottke PA, Stevens HY, Guldberg RE, Fedorov AG. Dynamic mass spectrometry probe for electrospray ionization mass spectrometry monitoring of bioreactors for therapeutic cell manufacturing. Biotechnol Bioeng 2019; 116:121-131. [PMID: 30199089 PMCID: PMC6310154 DOI: 10.1002/bit.26832] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2018] [Revised: 08/29/2018] [Accepted: 09/05/2018] [Indexed: 01/08/2023]
Abstract
Large-scale manufacturing of therapeutic cells requires bioreactor technologies with online feedback control enabled by monitoring of secreted biomolecular critical quality attributes (CQAs). Electrospray ionization mass spectrometry (ESI-MS) is a highly sensitive label-free method to detect and identify biomolecules, but requires extensive sample preparation before analysis, making online application of ESI-MS challenging. We present a microfabricated, monolithically integrated device capable of continuous sample collection, treatment, and direct infusion for ESI-MS detection of biomolecules in high-salt solutions. The dynamic mass spectrometry probe (DMSP) uses a microfluidic mass exchanger to rapidly condition samples for online MS analysis by removing interfering salts, while concurrently introducing MS signal enhancers to the sample for sensitive biomolecular detection. Exploiting this active conditioning capability increases MS signal intensity and signal-to-noise ratio. As a result, sensitivity for low-concentration biomolecules is significantly improved, and multiple proteins can be detected from chemically complex samples. Thus, the DMSP has significant potential to serve as an enabling portion of a novel analytical tool for discovery and monitoring of CQAs relevant to therapeutic cell manufacturing.
Collapse
Affiliation(s)
- Mason A. Chilmonczyk
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Peter A. Kottke
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Hazel Y. Stevens
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Robert E. Guldberg
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
- NSF ERC Center for Therapeutic Cell Manufacturing (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| | - Andrei G. Fedorov
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
- NSF ERC Center for Therapeutic Cell Manufacturing (CMaT), Parker H. Petit Institute for Bioengineering & Biosciences, Georgia Institute of Technology, Atlanta, Georgia
| |
Collapse
|
9
|
Wu W, Zhang D, Chen K, Zhou P, Zhao M, Qiao L, Su B. Highly Efficient Desalting by Silica Isoporous Membrane-Based Microfluidic Chip for Electrospray Ionization Mass Spectrometry. Anal Chem 2018; 90:14395-14401. [DOI: 10.1021/acs.analchem.8b03934] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Wanhao Wu
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Dongxue Zhang
- Department of Chemistry, Fudan University, Shanghai 200438, China
| | - Kexin Chen
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Ping Zhou
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Meijiao Zhao
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | - Liang Qiao
- Department of Chemistry, Fudan University, Shanghai 200438, China
| | - Bin Su
- Institute of Analytical Chemistry, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| |
Collapse
|
10
|
Giordano GF, Vieira LCS, Gobbi AL, Kubota LT, Lima RS. Gravity-assisted distillation on a chip: Fabrication, characterization, and applications. Anal Chim Acta 2018; 1033:128-136. [PMID: 30172318 DOI: 10.1016/j.aca.2018.05.028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 04/11/2018] [Accepted: 05/07/2018] [Indexed: 11/24/2022]
Abstract
Distillation is widely used in industrial processes and laboratories for sample pre-treatment. The conventional apparatus of flash distillation is composed of heating source, distilling flask, condenser, and receiving flask. As disadvantages, this method shows manual and laborious analyses with high consumption of chemicals. In this paper, all these limitations were addressed by developing a fully integrated microscale distiller in agreement with the apparatus of conventional flash distillation. The main challenge facing the distillation miniaturization is the phase separation since surface forces take over from the gravity in microscale channels. Otherwise, our chip had ability to perform gravity-assisted distillations because of the somewhat large dimensions of the distillation chamber (roughly 900 μL) that was obtained by 3D-printing. The functional distillation units were integrated into a single device composed of polydimethylsiloxane (PDMS). Its fabrication was cost-effective and simple by avoiding the use of cleanroom and bonding step. In addition to user-friendly analysis and low consumption of chemicals, the method requires cost-effective instrumentation, namely, voltage supply and analytical balance. Furthermore, the so called distillation-on-a-chip (DOC) eliminates the use of membranes and electrodes (usually employed in microfluidic desalinations reported in the literature), thus avoiding drawbacks such as liquid leakage, membrane fouling, and electrode passivation. The DOC promoted desalinations at harsh salinity (NaCl 600.0 mmol L-1) with high throughput and salt removal efficiency (roughly 99%). Besides, the method was used for determination of ethanol in alcoholic beverages to show the potential of the approach toward quantitative purposes.
Collapse
Affiliation(s)
- Gabriela Furlan Giordano
- Laboratório Nacional de Nanotecnologia (LNNano), Centro Nacional de Pesquisa Em Energia e Materiais (CNPEM), Campinas, São Paulo, 13083-970, Brazil; Instituto de Química, Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, 13083-970, Brazil
| | - Luis Carlos Silveira Vieira
- Laboratório Nacional de Nanotecnologia (LNNano), Centro Nacional de Pesquisa Em Energia e Materiais (CNPEM), Campinas, São Paulo, 13083-970, Brazil
| | - Angelo Luiz Gobbi
- Laboratório Nacional de Nanotecnologia (LNNano), Centro Nacional de Pesquisa Em Energia e Materiais (CNPEM), Campinas, São Paulo, 13083-970, Brazil
| | - Lauro Tatsuo Kubota
- Instituto de Química, Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, 13083-970, Brazil
| | - Renato Sousa Lima
- Laboratório Nacional de Nanotecnologia (LNNano), Centro Nacional de Pesquisa Em Energia e Materiais (CNPEM), Campinas, São Paulo, 13083-970, Brazil; Instituto de Química, Universidade Estadual de Campinas (UNICAMP), Campinas, São Paulo, 13083-970, Brazil.
| |
Collapse
|
11
|
Kubáň P. Salt Removal from Microliter Sample Volumes by Multiple Phase Microelectromembrane Extractions Across Free Liquid Membranes. Anal Chem 2017; 89:8476-8483. [DOI: 10.1021/acs.analchem.7b02017] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic
| |
Collapse
|
12
|
Tubaon RM, Haddad PR, Quirino JP. Sample Clean‐up Strategies for ESI Mass Spectrometry Applications in Bottom‐up Proteomics: Trends from 2012 to 2016. Proteomics 2017; 17. [DOI: 10.1002/pmic.201700011] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 02/09/2017] [Indexed: 12/11/2022]
Affiliation(s)
- Ria Marni Tubaon
- Australian Centre for Research on Separation Science School of Physical Sciences‐Chemistry University of Tasmania Hobart Tasmania Australia
| | - Paul R. Haddad
- Australian Centre for Research on Separation Science School of Physical Sciences‐Chemistry University of Tasmania Hobart Tasmania Australia
| | - Joselito P. Quirino
- Australian Centre for Research on Separation Science School of Physical Sciences‐Chemistry University of Tasmania Hobart Tasmania Australia
| |
Collapse
|
13
|
Tubaon RM, Haddad PR, Quirino JP. One-step selective electrokinetic removal of inorganic anions from small volumes and its application as sample clean-up for mass spectrometric techniques. J Chromatogr A 2017; 1488:134-139. [DOI: 10.1016/j.chroma.2017.01.073] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 01/24/2017] [Accepted: 01/26/2017] [Indexed: 12/26/2022]
|
14
|
Challenges for the in vivo quantification of brain neuropeptides using microdialysis sampling and LC-MS. Bioanalysis 2016; 8:1965-85. [PMID: 27554986 DOI: 10.4155/bio-2016-0119] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
In recent years, neuropeptides and their receptors have received an increased interest in neuropharmacological research. Although these molecules are considered relatively small compared with proteins, their in vivo quantification using microdialysis is more challenging than for small molecules. Low microdialysis recoveries, aspecific adsorption and the presence of various multiply charged precursor ions during ESI-MS/MS detection hampers the in vivo quantification of these low abundant biomolecules. Every step in the workflow, from sampling until analysis, has to be optimized to enable the sensitive analysis of these compounds in microdialysates.
Collapse
|
15
|
Roelofs SH, van den Berg A, Odijk M. Microfluidic desalination techniques and their potential applications. LAB ON A CHIP 2015; 15:3428-3438. [PMID: 26226407 DOI: 10.1039/c5lc00481k] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
In this review we discuss recent developments in the emerging research field of miniaturized desalination. Traditionally desalination is performed to convert salt water into potable water and research is focused on improving performance of large-scale desalination plants. Microfluidic desalination offers several new opportunities in comparison to macro-scale desalination, such as providing a platform to increase fundamental knowledge of ion transport on the nano- and microfluidic scale and new microfluidic sample preparation methods. This approach has also lead to the development of new desalination techniques, based on micro/nanofluidic ion-transport phenomena, which are potential candidates for up-scaling to (portable) drinking water devices. This review assesses microfluidic desalination techniques on their applications and is meant to contribute to further implementation of microfluidic desalination techniques in the lab-on-chip community.
Collapse
Affiliation(s)
- S H Roelofs
- BIOS - the Lab-on-a-Chip group, Mesa+ Institute for Nanotechnology, MIRA Institute, University of Twente, P.O. box 217, 7500 AE Enschede, The Netherlands.
| | | | | |
Collapse
|
16
|
Zhang M, Lin F, Xu J, Xu W. Membrane electrospray ionization for direct ultrasensitive biomarker quantitation in biofluids using mass spectrometry. Anal Chem 2015; 87:3123-8. [PMID: 25728048 DOI: 10.1021/acs.analchem.5b00467] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The ability of rapid biomarker quantitation in raw biological samples would expand the application of mass spectrometry in clinical diagnosis. Up until now, the conventional chromatography-mass spectrometry method is time-consuming in both sample preparation and chromatography separation processes, while ambient ionization methods normally suffer from sensitivity. The membrane electrospray ionization (MESI) introduced in this study could not only achieve sensitive biomolecule quantitation, but also minimize the sample handling process. As a unique feature of MESI, both vertical and horizontal chemical separations could be achieved in real-time. With the capability of mass-selectively minimizing matrix effects from salts, small molecules, and macromolecules, ultrasensitive detection of cytochrome C (>500-fold sensitivity improvement) in raw urine samples was demonstrated in less than 20 min.
Collapse
Affiliation(s)
- Mei Zhang
- †National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China, 102206.,‡State Key Laboratory for Infectious Disease Prevention and Control, Beijing, China, 102206.,§Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China, 310003
| | - Fankai Lin
- ⊥School of Life Science, Beijing Institute of Technology, Beijing, China, 100081
| | - Jianguo Xu
- †National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China, 102206.,‡State Key Laboratory for Infectious Disease Prevention and Control, Beijing, China, 102206.,§Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, China, 310003
| | - Wei Xu
- ⊥School of Life Science, Beijing Institute of Technology, Beijing, China, 100081
| |
Collapse
|