1
|
Qi H, Yue S, Bi S, Ding C, Song W. Isothermal exponential amplification techniques: From basic principles to applications in electrochemical biosensors. Biosens Bioelectron 2018; 110:207-217. [PMID: 29625328 DOI: 10.1016/j.bios.2018.03.065] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Revised: 03/16/2018] [Accepted: 03/28/2018] [Indexed: 12/12/2022]
Abstract
As a conventional amplification technique, polymerase chain reaction (PCR) has been widely applied to detect a variety of analytes with exponential amplification efficiency. However, the requirement of thermocycling procedures largely limits the application of PCR-based methods. Alternatively, several isothermal amplification techniques have been developed since the early 1990s. In particular, according to the reaction kinetics, isothermal exponential amplification techniques possess higher amplification efficiency and detection sensitivity. The isothermal exponential amplification techniques can be mainly divided into two categories: enzyme-based isothermal exponential amplification and enzyme-free isothermal exponential amplification. Considering the advantages of high sensitivity and selectivity, high signal-to-noise ratio, low cost and rapid response time, exponential amplification electrochemical biosensors have attracted considerable attention. In this review, we introduce the basic principles of isothermal exponential amplification techniques and summarize their applications in electrochemical biosensors during the past five years. We also highlighted the present challenges and further perspectives of isothermal exponential amplification-based electrochemical biosensors.
Collapse
Affiliation(s)
- Hongjie Qi
- College of Chemistry and Chemical Engineering, Shandong Demonstration Center for Experimental Chemistry Education, Qingdao University, Qingdao 266071, PR China
| | - Shuzhen Yue
- College of Chemistry and Chemical Engineering, Shandong Demonstration Center for Experimental Chemistry Education, Qingdao University, Qingdao 266071, PR China
| | - Sai Bi
- College of Chemistry and Chemical Engineering, Shandong Demonstration Center for Experimental Chemistry Education, Qingdao University, Qingdao 266071, PR China.
| | - Caifeng Ding
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| | - Weiling Song
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| |
Collapse
|
2
|
Walsh T, Lee J, Park K. Laser-assisted photothermal heating of a plasmonic nanoparticle-suspended droplet in a microchannel. Analyst 2015; 140:1535-42. [DOI: 10.1039/c4an01750a] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The present article reports the numerical and experimental investigations on the laser-assisted photothermal heating of a nanoliter-sized droplet in a microchannel when plasmonic particles are suspended in the droplet.
Collapse
Affiliation(s)
- Timothy Walsh
- Department of Mechanical
- Industrial and Systems Engineering
- University of Rhode Island
- Kingston
- USA
| | - Jungchul Lee
- Department of Mechanical Engineering
- Sogang University
- Seoul
- South Korea
| | - Keunhan Park
- Department of Mechanical Engineering
- University of Utah
- Salt Lake City
- USA
| |
Collapse
|
3
|
Ostendorff HP, Awad A, Braunschweiger KI, Liu Z, Wan Z, Rothschild KJ, Lim MJ. Multiplexed VeraCode bead-based serological immunoassay for colorectal cancer. J Immunol Methods 2013; 400-401:58-69. [PMID: 24161315 DOI: 10.1016/j.jim.2013.09.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Revised: 09/13/2013] [Accepted: 09/17/2013] [Indexed: 02/06/2023]
Abstract
Colorectal cancer (CRC) is the second leading cause of cancer deaths in the US and Western world. Despite increased screening and advances in treatment, the mortality rate (ca. 50,000/year) and high national health-care burden for CRC are likely to remain high unless an effective non-invasive screening test for CRC is instituted for a large segment of the population. Blood-based protein biomarkers hold great promise for early disease diagnosis and personalized medicine; yet robust and reproducible multiplexing platforms and methodologies have lagged behind their genomic counterparts. Here, we report the development of a novel, multiplexed, hybrid immunoassay for CRC that is formatted on barcoded VeraCode™ micro-beads, which have until now only been used for genomic assays. The method combines a sandwich immunoassay format for detection of serum protein biomarkers with an antigen assay for autoantibody detection. The serum protein biomarkers CEA and GDF15 as well as autoantibodies to the p53 tumor associated antigen (TAA) were used to exemplify the method. This multiplex biomarker panel was configured to run on Illumina's holographically barcoded VeraCode™ micro-bead platform, which is capable of measuring hundreds of analytes simultaneously in a single well from small volumes of blood (<50 μL) using a 96-well industry standard microtiter plate. This novel use of the VeraCode™ micro-bead platform translates into a potentially low volume, high throughput, multiplexed assay for CRC, for the purposes of biomarker validation, as well as patient screening, diagnostics and prognostics. In an evaluation of a 186 patient sera training set (CRC and normal), we obtained a diagnostic sensitivity of 54% and a specificity of 98%. We anticipate that by expanding and refining the biomarkers in this initial panel, and performing more extensive clinical validations, such an assay could ultimately provide a basis for CRC population screening to complement the more invasive, expensive and low throughput (but highly sensitive and specific) colonoscopy.
Collapse
|
4
|
Cao Q, Mahalanabis M, Chang J, Carey B, Hsieh C, Stanley A, Odell CA, Mitchell P, Feldman J, Pollock NR, Klapperich CM. Microfluidic chip for molecular amplification of influenza A RNA in human respiratory specimens. PLoS One 2012; 7:e33176. [PMID: 22457740 PMCID: PMC3310856 DOI: 10.1371/journal.pone.0033176] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2011] [Accepted: 02/05/2012] [Indexed: 11/18/2022] Open
Abstract
A rapid, low cost, accurate point-of-care (POC) device to detect influenza virus is needed for effective treatment and control of both seasonal and pandemic strains. We developed a single-use microfluidic chip that integrates solid phase extraction (SPE) and molecular amplification via a reverse transcription polymerase chain reaction (RT-PCR) to amplify influenza virus type A RNA. We demonstrated the ability of the chip to amplify influenza A RNA in human nasopharyngeal aspirate (NPA) and nasopharyngeal swab (NPS) specimens collected at two clinical sites from 2008-2010. The microfluidic test was dramatically more sensitive than two currently used rapid immunoassays and had high specificity that was essentially equivalent to the rapid assays and direct fluorescent antigen (DFA) testing. We report 96% (CI 89%,99%) sensitivity and 100% (CI 95%,100%) specificity compared to conventional (bench top) RT-PCR based on the testing of n = 146 specimens (positive predictive value = 100%(CI 94%,100%) and negative predictive value = 96%(CI 88%,98%)). These results compare well with DFA performed on samples taken during the same time period (98% (CI 91%,100%) sensitivity and 96%(CI 86%,99%) specificity compared to our gold standard testing). Rapid immunoassay tests on samples taken during the enrollment period were less reliable (49%(CI 38%,61%) sensitivity and 98%(CI 98%,100%) specificity). The microfluidic test extracted and amplified influenza A RNA directly from clinical specimens with viral loads down to 10³ copies/ml in 3 h or less. The new test represents a major improvement over viral culture in terms of turn around time, over rapid immunoassay tests in terms of sensitivity, and over bench top RT-PCR and DFA in terms of ease of use and portability.
Collapse
Affiliation(s)
- Qingqing Cao
- Department of Mechanical Engineering, Boston University, Boston, Massachusetts, United States of America
| | - Madhumita Mahalanabis
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, United States of America
| | - Jessie Chang
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, United States of America
| | - Brendan Carey
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, United States of America
| | - Christopher Hsieh
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, United States of America
| | - Ahjegannie Stanley
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, United States of America
| | - Christine A. Odell
- Department of Pediatrics, Division of Pediatric Emergency Medicine, Boston Medical Center and Boston University School of Medicine, Boston, Massachusetts, United States of America
| | - Patricia Mitchell
- Department of Emergency Medicine, Boston Medical Center and Boston University School of Medicine, Boston, Massachusetts, United States of America
| | - James Feldman
- Department of Emergency Medicine, Boston Medical Center and Boston University School of Medicine, Boston, Massachusetts, United States of America
| | - Nira R. Pollock
- Division of Infectious Diseases, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Catherine M. Klapperich
- Department of Mechanical Engineering, Boston University, Boston, Massachusetts, United States of America
- Department of Biomedical Engineering, Boston University, Boston, Massachusetts, United States of America
- * E-mail:
| |
Collapse
|
5
|
Abstract
Diagnostic assays are an important part of health care, both in the clinic and in research laboratories. In addition to improving treatments and clinical outcomes, rapid and reliable diagnostics help track disease epidemiology, curb infectious outbreaks, and further the understanding of chronic illness. Disease markers such as antigens, RNA, and DNA are present at low concentrations in biological samples, such that the majority of diagnostic assays rely on an amplification reaction before detection is possible. Ideally, these amplification reactions would be sensitive, specific, inexpensive, rapid, integrated, and automated. Microfluidic technology currently in development offers many advantages over conventional benchtop reactions that help achieve these goals. The small reaction volumes and energy consumption make reactions cheaper and more efficient in a microfluidic reactor. Additionally, the channel architecture could be designed to perform multiple tests or experimental steps on one integrated, automated platform. This review explores the current research on microfluidic reactors designed to aid diagnostic applications, covering a broad spectrum of amplification techniques and designs.
Collapse
Affiliation(s)
- Stephanie E McCalla
- Center for Biomedical Engineering, School of Engineering and Medical Sciences, Brown University, Providence, RI 02912, USA
| | | |
Collapse
|
6
|
Angione SL, Chauhan A, Tripathi A. Real-Time Droplet DNA Amplification with a New Tablet Platform. Anal Chem 2012; 84:2654-61. [DOI: 10.1021/ac202532a] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Stephanie L. Angione
- Center for Biomedical Engineering,
School of Engineering and Division of Biology and Medicine, Brown University, Providence, Rhode Island, United
States
| | - Anuj Chauhan
- Department of Chemical
Engineering, University of Florida, Gainesville,
Florida, United
States
| | - Anubhav Tripathi
- Center for Biomedical Engineering,
School of Engineering and Division of Biology and Medicine, Brown University, Providence, Rhode Island, United
States
| |
Collapse
|
7
|
Rossmanith P, Wagner M. A novel poisson distribution-based approach for testing boundaries of real-time PCR assays for food pathogen quantification. J Food Prot 2011; 74:1404-12. [PMID: 21902908 DOI: 10.4315/0362-028x.jfp-10-458] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The validation of quantitative real-time PCR systems and above all, proof of the detection limit of this method, is a frequently and intensively discussed topic in food pathogen detection. Among proper sample collection, assay design, careful experimental design, execution of real-time PCR, and data analysis, the validation of the method per se ensuring reliable quantification data is of prime importance. The purpose of this study was to evaluate a novel validation tool for real-time PCR assays, based on the theoretical possibility of the amplification of a single DNA target. The underlying mathematical basis for the work is Poisson distribution, which describes patterns of low particle numbers in a volume. In this context, we focused on the quantitative aspect of real-time PCR for the first time. This allowed for demonstration of the reliable amplification of a lone target DNA molecule and the demonstration of the distinct discrimination between integer molecular numbers when using low initial copy numbers. A real-time PCR assay amplifying a 274-bp fragment of the positive regulatory protein A locus of Listeria monocytogenes was used for this work. Evidence for a linear range of quantification from a single target copy to 10 ng of target DNA was experimentally demonstrated, and evidence for the significance of this novel validation approach is presented here.
Collapse
Affiliation(s)
- Peter Rossmanith
- Christian Doppler Laboratory for Molecular Biological Food Analytics, Veterinärplatz 1, 1210 Vienna, Austria.
| | | |
Collapse
|
8
|
Asiello PJ, Baeumner AJ. Miniaturized isothermal nucleic acid amplification, a review. LAB ON A CHIP 2011; 11:1420-30. [PMID: 21387067 DOI: 10.1039/c0lc00666a] [Citation(s) in RCA: 287] [Impact Index Per Article: 22.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Micro-Total Analysis Systems (µTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.
Collapse
Affiliation(s)
- Peter J Asiello
- Department of Biological and Environmental Engineering, Cornell University, Ithaca, NY 14853, USA
| | | |
Collapse
|
9
|
Oita I, Halewyck H, Thys B, Rombaut B, Vander Heyden Y, Mangelings D. Microfluidics in macro-biomolecules analysis: macro inside in a nano world. Anal Bioanal Chem 2010; 398:239-64. [PMID: 20549494 PMCID: PMC7079953 DOI: 10.1007/s00216-010-3857-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2010] [Revised: 05/13/2010] [Accepted: 05/18/2010] [Indexed: 12/26/2022]
Abstract
Use of microfluidic devices in the life sciences and medicine has created the possibility of performing investigations at the molecular level. Moreover, microfluidic devices are also part of the technological framework that has enabled a new type of scientific information to be revealed, i.e. that based on intensive screening of complete sets of gene and protein sequences. A deeper bioanalytical perspective may provide quantitative and qualitative tools, enabling study of various diseases and, eventually, may offer support for the development of accurate and reliable methods for clinical assessment. This would open the way to molecule-based diagnostics, i.e. establish accurate diagnosis and disease prognosis based on identification and/or quantification of biomacromolecules, for example proteins or nucleic acids. Finally, the development of disposable and portable devices for molecule-based diagnosis would provide the perfect translation of the science behind life-science research into practical applications dedicated to patients and health practitioners. This review provides an analytical perspective of the impact of microfluidics on the detection and characterization of bio-macromolecules involved in pathological processes. The main features of molecule-based diagnostics and the specific requirements for the diagnostic devices are discussed. Further, the techniques currently used for testing bio-macromolecules for potential diagnostic purposes are identified, emphasizing the newest developments. Subsequently, the challenges of this type of application and the status of commercially available devices are highlighted, and future trends are noted.
Collapse
Affiliation(s)
- Iuliana Oita
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Hadewych Halewyck
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Bert Thys
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Bart Rombaut
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Yvan Vander Heyden
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Debby Mangelings
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| |
Collapse
|
10
|
Zhang C, Xing D. Single-Molecule DNA Amplification and Analysis Using Microfluidics. Chem Rev 2010; 110:4910-47. [DOI: 10.1021/cr900081z] [Citation(s) in RCA: 115] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Chunsun Zhang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Da Xing
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| |
Collapse
|
11
|
Mazutis L, Araghi AF, Miller OJ, Baret JC, Frenz L, Janoshazi A, Taly V, Miller BJ, Hutchison JB, Link D, Griffiths AD, Ryckelynck M. Droplet-based microfluidic systems for high-throughput single DNA molecule isothermal amplification and analysis. Anal Chem 2009; 81:4813-21. [PMID: 19518143 DOI: 10.1021/ac900403z] [Citation(s) in RCA: 189] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We have developed a method for high-throughput isothermal amplification of single DNA molecules in a droplet-based microfluidic system. DNA amplification in droplets was analyzed using an intercalating fluorochrome, allowing fast and accurate "digital" quantification of the template DNA based on the Poisson distribution of DNA molecules in droplets. The clonal amplified DNA in each 2 pL droplet was further analyzed by measuring the enzymatic activity of the encoded proteins after fusion with a 15 pL droplet containing an in vitro translation system.
Collapse
Affiliation(s)
- Linas Mazutis
- Institut de Science et d'Ingenierie Supramoleculaire, Universite de Strasbourg, CNRS UMR 7006, 8 allee Gaspard Monge, 67083 Strasbourg Cedex, France
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Potrich C, Lunelli L, Forti S, Vozzi D, Pasquardini L, Vanzetti L, Panciatichi C, Anderle M, Pederzolli C. Effect of materials for micro-electro-mechanical systems on PCR yield. EUROPEAN BIOPHYSICS JOURNAL: EBJ 2009; 39:979-86. [DOI: 10.1007/s00249-009-0466-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2009] [Revised: 04/27/2009] [Accepted: 04/29/2009] [Indexed: 11/28/2022]
|
13
|
Auld D, Simeonov A, Thomas C. Literature Search and Review. Assay Drug Dev Technol 2008. [DOI: 10.1089/adt.2008.9991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Doug Auld
- National Institutes of Health, Bethesda, MD
| | | | | |
Collapse
|