1
|
Schulz K, Helms H, Janich A. Full evaporation headspace technique with gas chromatography as a microchemical method for the rapid determination of gamma-hydroxybutyric acid (GHB) in serum samples. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
2
|
Zheng J, Kirkpatrick CL, Lee D, Han X, Martinez AI, Gallagher K, Evans RK, Mudur SV, Liang X, Drake J, Buhler LA, Mowery MD. A Full Evaporation Static Headspace Gas Chromatography Method with Nitrogen Phosphorous Detection for Ultrasensitive Analysis of Semi-volatile Nitrosamines in Pharmaceutical Products. AAPS J 2022; 24:23. [PMID: 34993666 PMCID: PMC8817102 DOI: 10.1208/s12248-021-00669-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 11/16/2021] [Indexed: 11/30/2022] Open
Abstract
The recent detection of potent carcinogenic nitrosamine impurities in several human medicines has triggered product recalls and interrupted the supply of critical medications for hundreds of millions of patients, illuminating the need for increased testing of nitrosamines in pharmaceutical products. However, the development of analytical methods for nitrosamine detection is challenging due to high sensitivity requirements, complex matrices, and the large number and variety of samples requiring testing. Herein, we report an analytical method for the analysis of a common nitrosamine, N-nitrosodimethylamine (NDMA), in pharmaceutical products using full evaporation static headspace gas chromatography with nitrogen phosphorous detection (FE-SHSGC-NPD). This method is sensitive, specific, accurate, and precise and has the potential to serve as a universal method for testing all semi-volatile nitrosamines across different drug products. Through elimination of the detrimental headspace-liquid partition, a quantitation limit of 0.25 ppb is achieved for NDMA, a significant improvement upon traditional LC-MS methods. The extraction of nitrosamines directly from solid sample not only simplifies the sample preparation procedure but also enables the method to be used for different products as is or with minor modifications, as demonstrated by the analysis of NDMA in 10+ pharmaceutical products. The in situ nitrosation that is commonly observed in GC methods for nitrosamine analysis was completely inhibited by the addition of a small volume solvent containing pyrogallol, phosphoric acid, and isopropanol. Employing simple procedures and low-cost instrumentation, this method can be implemented in any analytical laboratory for routine nitrosamine analysis, ensuring patient safety and uninterrupted supply of critical medications. Graphical Abstract ![]()
Collapse
Affiliation(s)
- Jinjian Zheng
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA.
| | - Christine L Kirkpatrick
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Daniel Lee
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Xinxin Han
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Ana I Martinez
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Kimberly Gallagher
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Rebecca K Evans
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Sanjay V Mudur
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Xihui Liang
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Jennifer Drake
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Leah A Buhler
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| | - Mark D Mowery
- Analytical Chemistry in Development and Supply, Merck Manufacturing Division, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, New Jersey, 07065, USA
| |
Collapse
|
3
|
Xie WQ, Gong YX, Yu KX. Enhancing the Sensitivity of Full Evaporation Technique Using Multiple Headspace Extraction Analysis. Chromatographia 2017. [DOI: 10.1007/s10337-017-3343-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
4
|
van Boxtel N, Wolfs K, van Schepdael A, Adams E. Evaluation of the full evaporation technique for quantitative analysis of high boiling compounds with high affinity for apolar matrices. J Chromatogr A 2014; 1348:63-70. [PMID: 24831424 DOI: 10.1016/j.chroma.2014.04.088] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2014] [Revised: 04/24/2014] [Accepted: 04/25/2014] [Indexed: 11/17/2022]
Abstract
In order to reduce inaccuracies due to possible matrix effects in conventional static headspace-gas chromatography (sHS-GC), it is standard practice to match the composition of calibration standards towards the composition of the sample to be analysed by adding blank matrix. However, the latter is not always available and in that case the full evaporation technique (FET) could be a solution. With FET a small sample volume is introduced in a HS vial and compounds of interest are completely evaporated. Hence no equilibrium between the condensed phase and vapour phase exists. Without the existence of an equilibrium, matrix effects are less likely to occur. Another issue often encountered with sHS-sampling is that low vapour pressure compounds with a high affinity for the dilution medium show a limited sensitivity. FET has proven to be an appropriate solution to address this problem too. In this work, the applicability of FET for the quantitative analysis of high boiling compounds in different complex apolar matrices is examined. Data show that FET is an excellent tool to overcome matrix effects often encountered with conventional sHS analysis. The tested method shows excellent accuracy with recovery values around 100% as well as repeatability with RSD values around 1% for the quantification of high boiling compounds (bp>200°C) such as camphor, menthol, methyl salicylate and ethyl salicylate in various matrices. LOQ values were found to be around 0.3μg per vial. Following validation of the technique, several topical pharmaceutical formulations like ThermoCream(®), Reflexspray(®), Vicks Vaporub(®) and Radosalil(®) were examined. For the latter, a comparison has been made with a sHS-method described in literature.
Collapse
Affiliation(s)
- Niels van Boxtel
- KU Leuven, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Kris Wolfs
- KU Leuven, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Ann van Schepdael
- KU Leuven, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium
| | - Erwin Adams
- KU Leuven, Pharmaceutical Analysis, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium.
| |
Collapse
|
5
|
Full evaporation headspace gas chromatography for sensitive determination of high boiling point volatile organic compounds in low boiling matrices. J Chromatogr A 2013; 1315:167-75. [DOI: 10.1016/j.chroma.2013.09.058] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Revised: 09/13/2013] [Accepted: 09/16/2013] [Indexed: 11/18/2022]
|
6
|
Use of the Charge Transfer Reactions for the Spectrophotometric Determination of Risperidone in Pure and in Dosage Forms. JOURNAL OF PHARMACEUTICS 2013; 2013:792186. [PMID: 26555994 PMCID: PMC4595964 DOI: 10.1155/2013/792186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2012] [Accepted: 10/31/2012] [Indexed: 11/18/2022]
Abstract
The aim of study was to develop and validate two simple, sensitive, and extraction-free spectrophotometric methods for the estimation of risperidone in both pure and pharmaceutical preparations. They are based on the charge transfer complexation reactions between risperidone (RSP) as n-electron donor and p-chloranilic acid (p-CA) in method A and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) in method B as π-acceptors. In method A, RSP reacts with p-CA in methanol to produce a bright pink-colored chromogen measured at 530 nm whereas, in method B, RSP reacts with DDQ in dichloromethane to form orange-colored complex with a maximum absorption at 460 nm. Beer's law was obeyed in the concentration range of 0-25 and 0-50 μg/mL with molar absorptivity of 1.29 × 10(4) and 0.48 × 10(4) L/moL/cm for RSP in methods A and B, respectively. The effects of variables such as reagents, time, and stability of the charge transfer complexes were investigated to optimize the procedures. The proposed methods have been successfully applied to the determination of RSP in pharmaceutical formulations. Results indicate that the methods are accurate, precise, and reproducible (relative standard deviation <2 %).
Collapse
|
7
|
Patel RB, Patel BG, Patel MR, Bhatt KK. HPTLc method development and validation for analysis of risperidone in formulations, and in-vitro release study. ACTA CHROMATOGR 2010. [DOI: 10.1556/achrom.22.2010.4.5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
8
|
Sitaramaraju Y, van Hul A, Wolfs K, Van Schepdael A, Hoogmartens J, Adams E. Static headspace gas chromatography of (semi-)volatile drugs in pharmaceuticals for topical use. J Pharm Biomed Anal 2008; 47:834-40. [DOI: 10.1016/j.jpba.2008.04.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2008] [Revised: 04/02/2008] [Accepted: 04/02/2008] [Indexed: 11/16/2022]
|
9
|
Non-destructive quantitative analysis of risperidone in film-coated tablets. J Pharm Biomed Anal 2008; 47:631-5. [DOI: 10.1016/j.jpba.2008.01.049] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2007] [Revised: 01/22/2008] [Accepted: 01/29/2008] [Indexed: 11/23/2022]
|
10
|
Hassan WES. Extractive Colorimetric Method for the Determination of Dothiepin Hydrochloride and Risperidone in Pure and in Dosage Forms. Chem Pharm Bull (Tokyo) 2008; 56:1092-6. [DOI: 10.1248/cpb.56.1092] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
11
|
Brault A, Agasse V, Cardinael P, Combret JC. The full evaporation technique: A promising alternative for residual solvents analysis in solid samples. J Sep Sci 2005; 28:380-6. [PMID: 15792253 DOI: 10.1002/jssc.200401851] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The static headspace technique is the most common approach to residual solvent analysis in pharmaceutical and environmental matrices. This paper presents an alternative tool where the volatile impurities are released from the matrix by working directly on a small amount of sample at a high equilibration temperature: the so-called Full Evaporation Technique (FET). The capability of this method was evaluated on a mixture of nine solvents, which belong to Class 3 in the classification of the European Pharmacopoeia Agency for residual solvents, at various levels of concentration: ethanol, acetone, 2-propanol, methyl acetate, 2-butanone, ethyl acetate, tetrahydrofuran, 2-methyl-1-propanol, 1-butanol. Data on linearity, accuracy, precision and sensitivity are reported. Use of an internal standard proved to be necessary when using such a method. The method is then successfully applied to the analysis of solvent traces in permethylated beta-cyclodextrin.
Collapse
Affiliation(s)
- Audrey Brault
- SMS EA 3233, IRCOF, Université de Rouen, UFR des Sciences, F-76821 Mont Saint Aignan, France
| | | | | | | |
Collapse
|
12
|
El-Sherif ZA, El-Zeany B, El-Houssini OM. High performance liquid chromatographic and thin layer densitometric methods for the determination of risperidone in the presence of its degradation products in bulk powder and in tablets. J Pharm Biomed Anal 2005; 36:975-81. [PMID: 15620522 DOI: 10.1016/j.jpba.2004.07.014] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2003] [Revised: 06/14/2004] [Accepted: 07/10/2004] [Indexed: 11/19/2022]
Abstract
Two reproducible stability indicating methods were developed for the determination of risperidone (RISP) in presence of its degradation products in pure form and in tablets. The first method was based on reversed phase high performance liquid chromatography (HPLC), on Lichrosorb RP C 18 column (250 mm i.d., 4 mm, 10 microm), using methanol:0.05 M potassium dihydrogen phosphate pH 7 (65:35 (v/v)) as the mobile phase at a flow rate of 1 ml min(-1) at ambient temperature. Quantification was achieved with UV detection at 280 nm over a concentration range of 25-500 microg ml(-1) with mean percentage recovery of 99.87 +/- 1.049. The method retained its accuracy in the presence of up to 90% of RISP degradation products. The second method was based on TLC separation of RISP from its degradation products followed by densitometric measurement of the intact drug spot at 280 nm. The separation was carried out on aluminum sheet of silica gel 60F254 using acetonitrile:methanol:propanol:triethanolamine (8.5:1.2:0.6:0.2 (v/v/v/v)), as the mobile phase, over a concentration range of 2-10 microg per spot and mean percentage recovery of 100.1 +/- 1.18. The two methods were simple, precise, sensitive and could be successfully applied for the determination of pure, laboratory prepared mixtures and tablets. The results obtained were compared with the manufacturer's method.
Collapse
Affiliation(s)
- Zeinab A El-Sherif
- National Organization for Drug Control and Research, 6 and 7 AboHazem St. Pyramids, PO Box 29, Giza, Egypt.
| | | | | |
Collapse
|
13
|
Abstract
The intention of this work was to develop a simple and fast procedure for a determination of small amounts of ethanol in aqueous protein containing solutions based on combined headspace gas chromatography. In order to provide for short analysis time static headspace methodology was considered for this purpose. In this context the influence of the matrix composition onto the analytical results has been established and internal standardization as well as a full evaporation technique have been evaluated as promising alternatives for a compensation of matrix effects. With respect to speed of analysis, simplicity of sample handling as well as the quality of the analytical performance parameters, precision and accuracy, the full evaporation technique proved to be superior. Thus, the static equilibration of a 20 microliters sample aliquot in a conventional headspace sample vial for 5 min at 100 degrees C is sufficient to obtain equilibrium conditions for gas chromatographic analysis. The accuracy of this method was verified by robust regression analysis and exhibited excellent robustness within the required limits of sample composition ranging from 0 to 20% (w/w) protein content and up to 5 g/l salt content.
Collapse
Affiliation(s)
- S Strassnig
- Institute for Analytical Chemistry, Micro- and Radiochemistry, Technical University of Graz, Austria
| | | |
Collapse
|
14
|
Van Pelt CK, Haggarty P, Brenna JT. Quantitative subfemtomole analysis of alpha-tocopherol and deuterated isotopomers in plasma using tabletop GC/MS/MS. Anal Chem 1998; 70:4369-75. [PMID: 9796421 DOI: 10.1021/ac980295n] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A rapid, high-selectivity method with subfemtomole sensitivity is reported for quantification of alpha-tocopherol in plasma-based gas chromatography/tandem mass spectrometry (GC/MS/MS) using a tabletop quadrupole ion trap mass spectrometer. Sample workup is rapid, consisting of protein precipitation followed by liquid/liquid extraction and O-trimethylsilyl derivatization of alpha-tocopherol (alpha-T-TMS) and an internal standard, 2,2,5,7,8-pentamethyl-6-chromanol (PC-TMS). Rudimentary chromatography was carried out using an 8-m DB-5 capillary column resulting in an analyte retention time of 7.2 min. No interferences from the plasma matrix were observed. The assay has a detection limit of 178 amol (89.6 fg) and a lower limit of quantification of 700 amol (350 fg) of derivatized alpha-tocopherol in diluted plasma; < 30 pL of plasma is estimated to yield sufficient alpha-tocopherol for quantitative analysis at typical concentrations found in humans. A calibration curve constructed from National Institute of Standards and Technology serum standards was linear in the working range of 1.9-1073 ng/mL (0.95-0.54 ng). Within- and between-day precision averaged 5.8% and did not exceed 11.3% for three concentrations of quality control (QC) solutions. The overall accuracy for the QC samples was within 7.2%. Storage studies showed that, alpha-T-TMS and PC-TMS are stable under conditions that might be encountered during analyses. In a test study, plasma kinetic curves for alpha-tocopherol-d6 and alpha-tocopherol-d3 were obtained for a catheterized pregnant ewe and her fetus who were simultaneously given a bolus injection of alpha-tocopherol-d6, to the ewe and alpha-tocopherol-d3 to the fetus. These data show that a tabletop GC ion trap can determine alpha-T-TMS and its isotopomers quantitatively at high selectivity in a complex matrix.
Collapse
Affiliation(s)
- C K Van Pelt
- Division of Nutritional Sciences, Cornell University, Ithaca, New York 14853, USA
| | | | | |
Collapse
|
15
|
Rossi DT, Hoffman KL, Janiczek-Dolphin N, Bockbrader H, Parker TD. Tandem-in-time mass spectrometry as a quantitative bioanalytical tool. Anal Chem 1997; 69:4519-23. [PMID: 9375513 DOI: 10.1021/ac970247n] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Tandem-in-time mass spectrometry, as implemented on an ion-trap detector (ITD), is the process whereby precursor ions are created, stored in a radio frequency (rf) trapping field, and then sequentially fragmented to form product ions by application of additional rf waveforms. As with any form of tandem mass spectrometry (MS/MS), tandem-in-time MS is highly selective, by virtue of both mass discrimination and specific gas-phase chemistry. Beyond this, however, tandem-in-time MS offers ion throughput efficiency and cost advantages over either quadrupole or sector instruments. This paper will describe the use of capillary gas chromatography combined with tandem-in-time mass spectrometry to quantify a novel therapeutic agent extracted from human plasma. For an example compound, a quantitation limit of 25 pg/mL (S/N approximately 10, 15 fmol on-column) was attained out of plasma. The interday imprecision was < or = 12.2% over a dynamic range extending to 10 ng/mL. Due to favorable ionization conditions for the test analytes, electron ionization resulted in formation of M+ ions, with very little fragmentation, allowing for maximum assay sensitivity. Although method characterization and validation demonstrated adequate instrumental performance, some lack of ruggedness was encountered during routine application.
Collapse
Affiliation(s)
- D T Rossi
- Department of Pharmacokinetics and Drug Metabolism, Parke-Davis Pharmaceutical Research, Division of Warner-Lambert Company, Ann Arbor, Michigan 48189, USA
| | | | | | | | | |
Collapse
|
16
|
Affiliation(s)
- R K Gilpin
- College of Science and Mathematics, Wright State University, Dayton, Ohio 45435, USA
| | | |
Collapse
|