1
|
Rahman M, Marzullo B, Holman SW, Barrow M, Ray AD, O’Connor PB. Advancing PROTAC Characterization: Structural Insights through Adducts and Multimodal Tandem-MS Strategies. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:285-299. [PMID: 38197777 PMCID: PMC10853971 DOI: 10.1021/jasms.3c00342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/21/2023] [Accepted: 12/25/2023] [Indexed: 01/11/2024]
Abstract
Proteolysis targeting chimeras (PROTACs) are specialized molecules that bind to a target protein and a ubiquitin ligase to facilitate protein degradation. Despite their significance, native PROTACs have not undergone tandem mass spectrometry (MS) analysis. To address this gap, we conducted a pioneering investigation on the fragmentation patterns of two PROTACs in development, dBET1 and VZ185. Employing diverse cations (sodium, lithium, and silver) and multiple tandem-MS techniques, we enhanced their structural characterization. Notably, lithium cations facilitated comprehensive positive-mode coverage for dBET1, while negative polarity mode offered richer insights. Employing de novo structure determination on 2DMS data from degradation studies yielded crucial insights. In the case of VZ185, various charge states were observed, with [M + 2H]2+ revealing fewer moieties than [M + H]+ due to charge-related factors. Augmenting structural details through silver adducts suggested both charge-directed and charge-remote fragmentation. This comprehensive investigation identifies frequently dissociated bonds across multiple fragmentation techniques, pinpointing optimal approaches for elucidating PROTAC structures. The findings contribute to advancing our understanding of PROTACs, pivotal for their continued development as promising therapeutic agents.
Collapse
Affiliation(s)
- Mohammed Rahman
- Department
of Chemistry, University of Warwick, Coventry, CV4 7AL, U.K.
- Department
of Physics, University of Warwick, Coventry, CV4 7AL, U.K.
| | - Bryan Marzullo
- Department
of Chemistry, University of Warwick, Coventry, CV4 7AL, U.K.
| | - Stephen W. Holman
- Chemical
Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Macclesfield, SK10 4TF, U.K.
| | - Mark Barrow
- Department
of Chemistry, University of Warwick, Coventry, CV4 7AL, U.K.
| | - Andrew D. Ray
- New
Modalities and Parenteral Development, Pharmaceutical Technology &
Development, Operations, AstraZeneca, Macclesfield, SK10 4TF, U.K.
| | - Peter B. O’Connor
- Department
of Chemistry, University of Warwick, Coventry, CV4 7AL, U.K.
| |
Collapse
|
2
|
Morgan TE, Floyd TG, Marzullo BP, Wootton CA, Barrow MP, Bristow AWT, Perrier S, O'Connor PB. Stochasticity of poly(2-oxazoline) oligomer hydrolysis determined by tandem mass spectrometry. Polym Chem 2022; 13:4162-4169. [PMID: 35923808 PMCID: PMC9294869 DOI: 10.1039/d2py00437b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/01/2022] [Indexed: 11/30/2022]
Abstract
Understanding modification of synthetic polymer structures is necessary for their accurate synthesis and potential applications. In this contribution, a series of partially hydrolyzed poly(2-oxazoline) species were produced forming poly[(2-polyoxazoline)-co-(ethylenimine)] (P(EtOx-co-EI)) copolymers; EI being the hydrolyzed product of Ox. Bulk mass spectrometry (MS) measurements accurately measured the EI content. Tandem mass spectrometry analysis of the EI content in the copolymer samples determined the distribution of each monomer within the copolymer and corresponded to a theoretically modelled random distribution. The EI distribution across the polymers was shown to be effected by the choice of terminus, with a permanent hydrolysis event observed at an OH terminus. A neighbouring group effect wasn't observed at the polymer length analysed (approximately 25-mer species), suggesting that previously observed neighbouring group effects require a larger polymer chain. Although clearly useful for random polymer distribution this approach may be applied to many systems containing non-specific modifications to determine if they are directed or random locations across peptides, proteins, polymers, and nucleic acids. Tandem mass spectrometry can be used to better understand modification sites of synthetic polymer structures providing more complete chemical knowledge which is necessary for their accurate synthesis and potential applications.![]()
Collapse
Affiliation(s)
- Tomos E Morgan
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Thomas G Floyd
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Bryan P Marzullo
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | | | - Mark P Barrow
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Anthony W T Bristow
- Chemical Development, Pharmaceutical Technology and Development, Operations, AstraZeneca Charter Way Macclesfield SK102NA UK
| | - Sébastien Perrier
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
- Warwick Medical School, University of Warwick Coventry CV4 7AL UK
- Faculty of Pharmaceutical Sciences, Monash University 381 Royal Parade Parkville VIC 3052 Australia
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| |
Collapse
|
3
|
Morgan TE, Wootton CA, Marzullo B, Paris J, Kerr A, Ellacott SH, van Agthoven MA, Barrow MP, Bristow AWT, Perrier S, O'Connor PB. Characterization Across a Dispersity: Polymer Mass Spectrometry in the Second Dimension. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2153-2161. [PMID: 34264672 DOI: 10.1021/jasms.1c00106] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Due to the natural dispersity that is present in synthetic polymers, an added complexity is always present in the analysis of polymeric species. Tandem mass spectrometry analysis requires the isolation of individual precursors before a fragmentation event to allow the unambiguous characterization of these species and is not viable at certain levels of complexity due to achievable isolation widths. Two-dimensional mass spectrometry (2DMS) fragments ions and correlates fragments with their corresponding precursors without the need for isolation. In this study, 2DMS electron capture dissociation (ECD) fragmentation of a polyoxazoline and polyacrylamide species was carried out, resulting in the analysis of byproducts and individual polymer species without the use of chromatographic techniques. This study shows that 2DMS ECD is a powerful tool for the analysis of polyacrylamide and polyoxazoline species and offers a new dimension in the characterization of polymers.
Collapse
Affiliation(s)
- Tomos E Morgan
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Christopher A Wootton
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Bryan Marzullo
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Johanna Paris
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Andrew Kerr
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Sean H Ellacott
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Maria A van Agthoven
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Mark P Barrow
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Anthony W T Bristow
- Chemical Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Macclesfield SK10 2NA, United Kingdom
| | - Sebastien Perrier
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
- Warwick Medical School, University of Warwick, Coventry CV4 7AL, United Kingdom
- Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| |
Collapse
|
4
|
Chagunda IC, Russell GT, McIndoe JS. The signal-to-noise issue in mass spectrometric analysis of polymers. Polym Chem 2021. [DOI: 10.1039/d1py00461a] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Mass spectrometric approaches to polymer analysis become increasingly ineffective as average molecular weight increases. This perspective explains these fundamental limits of MS for determining molecular weight distribution of high polymers.
Collapse
Affiliation(s)
| | - Gregory T. Russell
- School of Physical and Chemical Sciences
- University of Canterbury
- Christchurch 8140
- New Zealand
| | - J. Scott McIndoe
- Department of Chemistry
- University of Victoria
- Canada
- School of Physical and Chemical Sciences
- University of Canterbury
| |
Collapse
|
5
|
Yoo HJ, Kim DH, Shin D, Oh Y, Lee S, Lee JY, Choi YJ, Lee SH, Lee KS, Kim Y, Cho K. Recent developments in pre-treatment and analytical techniques for synthetic polymers by MALDI-TOF mass spectrometry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:5767-5800. [PMID: 33241791 DOI: 10.1039/d0ay01729a] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A great deal of effort has been expended to develop accurate means of determining the properties of synthetic polymers using matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). Many studies have focused on the importance of sample pre-treatment to obtain accurate analysis results. This review discusses the history of synthetic polymer characterization and highlights several applications of MALDI-TOF MS that recognize the importance of pre-treatment technologies. The subject area is of significance in the field of analytical chemistry, especially for users of the MALDI technique. Since the 2000s, many such technologies have been developed that feature improved methods and conditions, including solvent-free systems. In addition, the recent diversification of matrix types and the development of carbon-based matrix materials are described herein together with the current status and future directions of MALDI-TOF MS hardware and software development. We provide a summary of processes used for obtaining the best analytical results with synthetic polymeric materials using MALDI-TOF MS.
Collapse
Affiliation(s)
- Hee-Jin Yoo
- Center for Research Equipment, Korea Basic Science Institute, 162, Yeongudanji-ro, Ochang-eup, Cheongwon-gu, Cheongju-si, Chungcheongbuk-do 28119, Korea.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|