1
|
Zhan C, Lu P, Dong Y, Chen R, Yu D, Chen Y. Magnetic relaxation switching immunosensor based on polystyrene microcolumn and tyramine signal amplification for ultrasensitive and user-friendly detection of aflatoxin B 1 in corn. Food Chem 2024; 460:140362. [PMID: 39047485 DOI: 10.1016/j.foodchem.2024.140362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 06/20/2024] [Accepted: 07/03/2024] [Indexed: 07/27/2024]
Abstract
Aflatoxin B1 is highly mutagenic in humans, and long-term exposure can impair immunity and increase the risk of cancer. It is imperative to develop immunoassays with convenient operation and high sensitivity to detect aflatoxin B1. This study presents a polystyrene microcolumn-mediated magnetic relaxation switching immunosensor based on a tyramine signal amplification strategy for detecting aflatoxin B1. An environmentally friendly hand-held polystyrene microcolumn was designed as an effective immunoreaction carrier, remaining 91% efficiency after 12 repeated uses. And the microcolumn provides a user-friendly procedure for rapid separation and reagent switching within 3 s by simple stirring in solution. The combination of a strong anti-interference magnetic relaxation switching biosensing and an efficient tyramine signal amplification enables the quantitative detection of aflatoxin B1 in the range of 0.01-10 ng/mL, with a limit of detection of 0.006 ng/mL. This method has potential application in the rapid detection of trace food contaminants.
Collapse
Affiliation(s)
- Chen Zhan
- College of Informatics, Huazhong Agricultural University, Wuhan 430070, Hubei, China; State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian 116034, Liaoning, China
| | - Peng Lu
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China; State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian 116034, Liaoning, China
| | - Yongzhen Dong
- State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian 116034, Liaoning, China
| | - Rui Chen
- College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Deyang Yu
- State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian 116034, Liaoning, China
| | - Yiping Chen
- College of Informatics, Huazhong Agricultural University, Wuhan 430070, Hubei, China; College of Engineering, Huazhong Agricultural University, Wuhan 430070, Hubei, China; State Key Laboratory of Marine Food Processing and Safety Control, Dalian Polytechnic University, Dalian 116034, Liaoning, China..
| |
Collapse
|
2
|
Ren M, Dong Y, Wang J, Lin J, Qu L, Zhou Y, Chen Y. Computer vision-assisted smartphone microscope imaging digital immunosensor based on click chemistry-mediated microsphere counting technology for the detection of aflatoxin B 1 in peanuts. Anal Chim Acta 2023; 1278:341687. [PMID: 37709427 DOI: 10.1016/j.aca.2023.341687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 07/20/2023] [Accepted: 08/02/2023] [Indexed: 09/16/2023]
Abstract
Aflatoxin B1 is a carcinogenic contaminant in food or feed, and it poses a serious health risk to humans. Herein, a computer vision-assisted smartphone microscope imaging digital (SMID) immunosensor based on the click chemistry-mediated microsphere counting technology was designed for the detection of aflatoxin B1 in peanuts. In this SMID immunosensor, the modified polystyrene (PS) microspheres were used as the signal probes and were recorded by a smartphone microscopic imaging system after immunoreaction and click chemistry reaction. The number of PS probes is adjusted by aflatoxin B1. The customized computer vision procedure was used to efficiently identify and count the obtained PS probes. This SMID immunosensor enables sensitive detection of aflatoxin B1 with a linear range from 0.001 ng/mL to 500 ng/mL, providing a simple, sensitive, and portable tool for food safety supervision.
Collapse
Affiliation(s)
- Meijie Ren
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Yongzhen Dong
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, China
| | - Jianhan Lin
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing, 100083, China
| | - Lijie Qu
- Key Laboratory of Quality & Safety Analysis-Testing for Agro-Products and Food of Hebei Province, Hebei North University, No. 11 South Diamond Road, Zhangjiakou, 075000, China
| | - Yang Zhou
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Yiping Chen
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China.
| |
Collapse
|
3
|
Lu P, Zhan C, Huang C, Zhou Y, Hong F, Wang Z, Dong Y, Li N, He Q, Chen Y. Cartridge voltage-sensitive micropump immunosensor based on a self-assembled polydopamine coating mediated signal amplification strategy. Biosens Bioelectron 2023; 226:115087. [PMID: 36754742 DOI: 10.1016/j.bios.2023.115087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 01/10/2023] [Accepted: 01/17/2023] [Indexed: 01/19/2023]
Abstract
Current biosensing detection assays were developed to focus on rapid, low-cost, stable detection for clinical diagnosis and food safety monitoring. In this work, a novel portable cartridge voltage-sensitive micropump immunosensor (CVMS) biosensing device based on the integration of the microchannel circuit biosensing principle and polydopamine (PDA) was presented for rapid and sensitive detection of pathogenic factors in real samples at trace levels. The CVMS can sensitively evaluate voltage signal changes caused by clogging effects in the closed-loop circuit when the insulated microspheres pass through the microchannel. The targets could trigger the immune reaction between antibody-antigens that leads to the change in the concentration of horseradish peroxidase (HRP). And the HRP was further employed to catalyze the polymerization of dopamine into PDA, resulting in the rapid formation of the magnetic @PDA nanoparticles (MNP@PDA) with core-shell structures. The abundant functional groups on the MNP@PDA surface can efficiently adsorb polystyrene microspheres, thus causing changes in the number of polystyrene microspheres (PS). The CVMS can accurately monitor the change of PS with a portable device, which weighs less than 0.8 kg and costs only $50. The completion of CVMS takes 90 min to complete. The limit of detection of this immunosensor for procalcitonin and ochratoxin A were 42 pg/mL and 77 pg/mL, respectively, which improved about 15 folds and 38 folds, respectively, than those of enzyme-linked immunosorbent assay.
Collapse
Affiliation(s)
- Peng Lu
- College of Engineering, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Chen Zhan
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Chenxi Huang
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Yang Zhou
- College of Engineering, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Feng Hong
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Zhilong Wang
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Yongzhen Dong
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China
| | - Nan Li
- Daye Public Inspection and Test Center, Daye, 435100, Hubei, China
| | - Qifu He
- Daye Public Inspection and Test Center, Daye, 435100, Hubei, China
| | - Yiping Chen
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan, 430070, Hubei, China; Daye Public Inspection and Test Center, Daye, 435100, Hubei, China; Shenzhen Institute of Nutrition and Health, Huazhong Agricultural University, Wuhan, 430070, Hubei, China.
| |
Collapse
|
4
|
Wei L, Wang Z, Chen Y. Optical Biosensor for Ochratoxin A Detection in Grains Using an Enzyme-Mediated Click Reaction and Polystyrene Nanoparticles. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2022; 70:14798-14804. [PMID: 36372964 DOI: 10.1021/acs.jafc.2c05137] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Herein, we develop an optical biosensor for highly sensitive and facile detection of ochratoxin A (OTA) using an enzyme-mediated click reaction for signal amplification and polystyrene nanoparticles (PNPs) for signal readout. Alkaline phosphatase was employed to hydrolyze the ascorbic acid-phosphate to generate ascorbic acid, which reduces Cu(II) to Cu(I). Cu(I) can catalyze the click reaction between alkyne-functionalized magnetic beads and azide-functionalized PNPs to form complexes, while unbound PNPs acted as the signal probe. This strategy utilized the high efficiency of click chemistry and the inherent optical absorption properties of PNPs, which effectively improved the sensitivity of conventional immunoassays and simplified the procedures using magnetic separation technology. This optical biosensor enabled OTA detection in a linear range of 0.1 to 50 ng/mL with a detection limit of 54 pg/mL. Moreover, it has been successfully challenged with OTA detection in maize samples, revealing its potential as a promising tool for mycotoxin screening.
Collapse
Affiliation(s)
- Luyu Wei
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Zhilong Wang
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, Hubei, China
| | - Yiping Chen
- College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, Hubei, China
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou 510642, Guangdong, China
- Shenzhen Branch, Guangdong Laboratory for Lingnan Modern Agriculture, Genome Analysis Laboratory of the Ministry of Agriculture, Agricultural Genomics Institute at Shenzhen, Chinese Academy of Agricultural Sciences, Shenzhen 518120, Guangdong, China
| |
Collapse
|
5
|
Novel bioorthogonal reaction-mediated particle counting sensing platform using phage for rapid detection of Salmonella. Anal Chim Acta 2022; 1236:340564. [DOI: 10.1016/j.aca.2022.340564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 10/18/2022] [Accepted: 10/27/2022] [Indexed: 11/21/2022]
|