1
|
Xu X, Zhou X, Huang J, Liu Y, Zhang Z. High-Throughput Multitarget Molecular Detection in an Automatic Light-Addressable Photoelectrochemical Sensing Platform. Anal Chem 2024; 96:9185-9191. [PMID: 38773762 DOI: 10.1021/acs.analchem.4c01076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/24/2024]
Abstract
Successively emerged high-throughput multitarget molecular detection methods bring significant development tides in chemical, biological, and environmental fields. However, several persistent challenges of intricate sample preparation, expensive instruments, and tedious and skilled operations still need to be further addressed. Here, we propose an automatic light-addressable photoelectrochemical (ALA-PEC) sensing platform for sensitive and selective detection of multitarget molecules. With Au nanoparticle-decorated TiO2 nanotube photonic crystals (Au-TiO2 NTPCs) as a photoelectrode and 8 kinds of antibiotics as target molecules, the ALA-PEC sensing system implements automatic detection of multimolecules in a short time with high sensitivity and good selectivity. Random samples with different amounts of antibiotics have been well-distinguished in the ALA-PEC system, and both the chemical components and concentrations have been well-illustrated in a pattern recognition model. It is worth noting that 8 samples are not the limit of the ALA-PEC sensing platform, which can be easily expanded to more complex detection arrays based on practical needs. The emerging ALA-PEC sensing platform provides a new solution for rapid screening and detection of multitarget and high-throughput substances and potentially brings the automatic, portable, sensitive, high-throughput, and cost-effective detection technique to an entire new realm.
Collapse
Affiliation(s)
- Xiankui Xu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Xue Zhou
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Jing Huang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Yibin Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
| | - Zhonghai Zhang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200241, China
- State Key Laboratory of Petroleum Molecular and Process engineering, SKLPMPE, Sinopec Research Institute of Petroleum Processing Co., Ltd., Beijing 100083, China
| |
Collapse
|
2
|
Li X, Chen G, Li Y, Wang Y, Huang W, Lai G. Multiplex Signal Transduction and Output at Single Recognition Interface of Multiplexed Photoelectrochemical Sensors. Anal Chem 2024; 96:8147-8159. [PMID: 38568863 DOI: 10.1021/acs.analchem.3c05475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2024]
Affiliation(s)
- Xin Li
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China
| | - Guixiang Chen
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China
| | - Yishuang Li
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China
| | - Yuxin Wang
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China
| | - Wan Huang
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China
| | - Guosong Lai
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, P. R. China
| |
Collapse
|
3
|
Zhang S, Zhang Y, Wang H, Wang Y, Ma H, Wu D, Gao ZF, Fan D, Ren X, Wei Q. Magnetic photoelectrochemical sensor array utilizing addressing sensing strategy for simultaneous detection of amyloid-β 42 and microtubule-associated protein tau. Anal Chim Acta 2024; 1298:342407. [PMID: 38462332 DOI: 10.1016/j.aca.2024.342407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 02/01/2024] [Accepted: 02/22/2024] [Indexed: 03/12/2024]
Abstract
The accurate diagnosis of diseases can be improved by detecting multiple biomarkers simultaneously. This study presents the development of a magnetic photoelectrochemical (PEC) immunosensor array for the simultaneous detection of amyloid-β 42 (Aβ) and microtubule-associated protein (Tau), which are markers for neurodegenerative disorders. A metal-organic framework (MOF) derivative, Fe2O3@FeS2 magnetic composites with exceptional photoelectric and ferromagnetic properties was synthesized while preserving the original structure and advantages. Thus, the immunoassembly process of the sensor can be carried out in homogeneous solution and recovered by magnetic separation. For simultaneous detection, a chip is divided into multiple independent sensing sites, which have the same preparation and detection environment, allowing for the implementation of a self-calibration method. The sensor array demonstrates considerable detection ranges of 0.01-100 ng mL-1 for Aβ and 0.05-100 ng mL-1 for Tau, with low detection limits of 2.1 pg mL-1 for Aβ and 7.9 pg mL-1 for Tau. The PEC sensor array proposed in this study exhibits exceptional stability, selectivity, and reproducibility, providing a new method for detecting multiple markers.
Collapse
Affiliation(s)
- Shuo Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Yunfei Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Huan Wang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
| | - Yaoguang Wang
- Shandong Provincial Key Laboratory of Molecular Engineering, School of Chemistry and Chemical Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, PR China
| | - Hongmin Ma
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Dan Wu
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Zhong Feng Gao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Dawei Fan
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Xiang Ren
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
| |
Collapse
|
4
|
Liang H, Xiao Y, Chen R, Li Y, Zhou S, Liu J, Song Y, Wang L. Immunosensing of neuron-specific enolase based on signal amplification strategies via catalysis of ascorbic acid by heteropolysate COF. Biosens Bioelectron 2023; 238:115593. [PMID: 37597283 DOI: 10.1016/j.bios.2023.115593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 08/09/2023] [Accepted: 08/10/2023] [Indexed: 08/21/2023]
Abstract
In view of the importance of quantification of neuron-specific enolase (NSE), an electrochemical NSE immunosensor was developed. The sandwich voltammetric immunosensor utilized vinyl-functionalized crystalline covalent organic framework (COFTAPT-Dva) modified electrode to load lots of Ab1 via thiol-ene "click" reaction as matrix. A crystalline cationic EB-COF:Br was used to load Au nanoparticles (AuNPs) and H3[PMo12O40] (PMo12) as immunoprobe. The AuNPs with the size of about 30 nm were firstly grown on EB-COF:Br and then a large number of electroactive PMo12 were uniformly assembled on AuNPs/EB-COF:Br via ion exchanging reaction. The AuNPs not only facilitated the bonding of Ab2 based on Au-S bond, but also improved performance of Ab2/AuNPs/EB-COF:PMo12 immunoprobe. The sensitivity of sandwich electrochemical immunosensor could be primarily amplified based on loaded abundant PMo12. Secondary sensitivity amplification of immunosensor could be achieved by using PMo12 to catalyze ascorbic acid. The linear range of sandwich voltammetric immunosensor based on current change of differential pulse voltammetry is 500 ± 36 fg mL-1 - 100 ± 8 ng mL-1. Thanks to the dual sensitivity amplification strategy, the sensitivity is as high as 54.06 ± 3.2 μA cm-2/lg(cNSE/ng mL-1), and the detection limit is as low as 166 ± 10.8 fg mL-1. It proves that it is completely feasible to amplify sensitivity of sandwich voltammetric immunosensors using polyoxometalate-COF and its catalytic substrate.
Collapse
Affiliation(s)
- Huihui Liang
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China; Key Laboratory of Evaluation of Traditional Chinese Medicine Efficacy (Prevention and Treatment of Brain Disease with Mental Disorders), Jiangxi University of Chinese Medicine, 1688 Meiling Road, Nanchang, 330004, China
| | - Yawen Xiao
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China
| | - Rongfang Chen
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China
| | - Yanyan Li
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China
| | - Shilin Zhou
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China
| | - Jianming Liu
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China
| | - Yonghai Song
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China.
| | - Li Wang
- College of Chemistry and Chemical Engineering, Jiangxi Normal University, 99 Ziyang Road, Nanchang, 330022, China.
| |
Collapse
|
5
|
Geng W, Xue L, Li Y, Ji J, Yuan X, Ding L, Yang R. A dual-model immobilization-free photoelectrochemical/visual colorimetric bioanalysis based on microemulsion self-assemblies mediated multifunctional signal amplification strategy. Anal Chim Acta 2023; 1277:341644. [PMID: 37604608 DOI: 10.1016/j.aca.2023.341644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 07/19/2023] [Indexed: 08/23/2023]
Abstract
Herein, a novel silver ion-loaded gold microemulsion assemblies (Au/Ag+ MAs) mediated multifunctional signal amplification strategy was proposed to construct a sensitive immobilization-free photoelectrochemical (PEC)/colorimetric biosensor for carcinoembryonic antigen (CEA) detection. Through the sandwiched reaction among CEA, the CEA aptamer (DNA1) loaded on the Au nanoparticles (NPs) functionalized iron oxide (Fe3O4) nanospheres and another CEA aptamer (DNA2) immobilized on Au/Ag+ MAs, a complex is formed and acquired by magnetic separation. Then, Au/Ag+ MAs of the complex are disassembled into Au NPs and Ag+ ions driven by an acetone response, and the obtained demulsification solution is transferred to the cadmium sulfide/cadmium telluride (CdS/CdTe) photoactive composites modified electrode. Based on the multiple inhibition functions (blocking effect of oleylamine; energy transfer effect of Au NPs; and electron snatching effect of Ag+), the photocurrent of the electrode decreases obviously, resulting in the ultrasensitive detection of CEA (a detection limit of 16 fg mL-1). Interestingly, the ion-exchange reactions between CdS/CdTe composites and Ag+ ions generate silver sulfide/silver telluride (Ag2S/Ag2Te) composites, and a color change of composites can be distinguished directly, leading to a quick visual detection of CEA. Compared with the traditional single-modal assay for CEA, such dual-modal PEC/colorimetric assay is a more accurate and reliable due to different mechanisms and independent signal conversion. This work will offer a new perspective for the applications of various self-assemblies in PEC bioanalysis.
Collapse
Affiliation(s)
- Wenchao Geng
- School of Chemical and Printing Dyeing Engineering, Henan University of Engineering, Zhengzhou, 451191, China
| | - Linsheng Xue
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Yuling Li
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Jiangying Ji
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Xinxin Yuan
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Lihua Ding
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Ruiying Yang
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China.
| |
Collapse
|
6
|
Wang H, Wu F, Wu L, Guan J, Niu X. Nanozyme colorimetric sensor array based on monatomic cobalt for the discrimination of sulfur-containing metal salts. JOURNAL OF HAZARDOUS MATERIALS 2023; 456:131643. [PMID: 37236116 DOI: 10.1016/j.jhazmat.2023.131643] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Revised: 05/04/2023] [Accepted: 05/13/2023] [Indexed: 05/28/2023]
Abstract
The identification of sulfur-containing metal salts (SCMs) is of great interest because they play an important role in many biological processes and diseases. Here, we constructed a ternary channel colorimetric sensor array to detect multiple SCMs simultaneously, relying on monatomic Co embedded in nitrogen-doped graphene nanozyme (CoN4-G). Due to the unique structure, CoN4-G exhibits activity similar to native oxidases, capable of catalysing directly the oxidization of 3,3',5,5'-tetramethylbenzidine (TMB) by O2 molecules independent of H2O2. Density functional theory (DFT) calculations suggest that CoN4-G has no potential barrier in the whole reaction route, thus presenting higher oxidase-like catalytic activity. Based on different degrees of TMB oxidation, different colorimetric response changes are obtained as "fingerprints" on the sensor array. The sensor array can discriminate different concentrations of unitary, binary, ternary, and quaternary SCMs and has been successfully applied to detect six real samples (soil, milk, red wine and egg white). To advance the field detection of the above four types of SCMs, we creatively propose a smartphone-based autonomous detection platform with a linear range of 1.6-320 μM and a limit of detection of 0.0778-0.218 μM, which demonstrates the potential use of sensor arrays in the application of disease diagnosis and food and environment monitoring.
Collapse
Affiliation(s)
- Hongsu Wang
- College of Food Science and Engineering, Jilin University, Changchun 130062, PR China
| | - Fengling Wu
- College of Food Science and Engineering, Jilin University, Changchun 130062, PR China
| | - Lifang Wu
- College of Food Science and Engineering, Jilin University, Changchun 130062, PR China
| | - Jingqi Guan
- Institute of Physical Chemistry, College of Chemistry, Jilin University, 2519 Jiefang Road, Changchun 130021, PR China.
| | - Xiaodi Niu
- College of Food Science and Engineering, Jilin University, Changchun 130062, PR China.
| |
Collapse
|
7
|
Guo Y, Dai X, Zhang Y, Ma S, Yang L, Bu Y, Hao Y. Universal Hydrogen-Treated TiO 2 Nanorod Array/Ti 2CO X MXene PEC Aptamer Sensor Modulated by the Transport Characteristic of Photogenerated Holes. Anal Chem 2023; 95:7560-7568. [PMID: 37134286 DOI: 10.1021/acs.analchem.3c00046] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
A semiconductor photoelectrochemical (PEC) aptamer sensor has been widely researched in recent years because of its broad application prospects. However, a universal PEC sensor has not been achieved, and its sensing mechanism based on a photogenerated carrier transfer process has yet to be elucidated. Herein, a novel hydrogen-treated TiO2 nanorod array one-dimensional (1D)/Ti2COX MXene two-dimensional (2D) (H-TiO2/Ti2COX) PEC aptamer sensor is presented, which achieved a record detection range of 10-9-103 μg/L and a limit of detection (LOD) of 1 fg/L for microcystic toxins-LR detection. Besides, the PEC sensor can also test serotonin (5-HT), aflatoxin-B1, and prostate-specific antigen (PSA) with high performance by changing the aptamers, exhibiting favorable application universality. Furthermore, a new phenomenon of a switchable enhanced/suppressed photocurrent detection signal was discovered from H-TiO2/Ti2COX PEC aptamer sensors through the variation of the length of the TiO2 nanorod. Meanwhile, it reveals that the steric hindrance effect determines the photogenerated hole transfer and depolarization processes, which is proposed for the first time as the predominant mechanism of the switchable enhanced/suppressed photocurrent signal for PEC sensors, giving possibilities to develop PEC sensors with higher efficiency.
Collapse
Affiliation(s)
- Yiwei Guo
- Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Xianying Dai
- Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Yan Zhang
- Xi'an Mental Health Center, Xi'an 710061, China
| | - Shenhui Ma
- Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Liu Yang
- Xi'an Mental Health Center, Xi'an 710061, China
| | - Yuyu Bu
- Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi'an 710071, China
| | - Yue Hao
- Key Laboratory of Wide Band-Gap Semiconductor Materials and Devices, School of Microelectronics, Xidian University, Xi'an 710071, China
| |
Collapse
|
8
|
Fan D, Luo J, Gong Z, Niu J, Wang H, Wu D, Wei Q. Polyacrylic acid/polyethylene glycol hybrid antifouling interface for photoelectrochemical immunosensing of CYFRA 21-1 based on TiO 2/PpIX/Ag@Cu 2O composite. Talanta 2023; 260:124570. [PMID: 37094452 DOI: 10.1016/j.talanta.2023.124570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 04/12/2023] [Accepted: 04/17/2023] [Indexed: 04/26/2023]
Abstract
A photoelectrochemical (PEC) transducer based on composite TiO2/PpIX/Ag@Cu2O was prepared for the detection of CYFRA 21-1. TiO2 nanomaterials were synthesized by hydrothermal method. TiO2/PpIX/Ag@Cu2O composites were obtained by combining protoporphyrin Ⅸ (PpIX) molecules and Ag@Cu2O on TiO2. This composite material has strong absorption in visible light region and excellent photoelectric chemical properties. Ascorbic acid (AA) is a good electron donor, which can remove photogenerated holes in liquid environment to inhibit the recombination of photogenerated electrons and hole pairs, thus enhancing the photocurrent and improving its stability. The results showed that the sensor can quantitatively test CYFRA 21-1 in the range of 0.1 pg/mL∼100 ng/mL. The photoelectric chemical sensor has the advantages of high sensitivity, low detection line limit and wide linear range.
Collapse
Affiliation(s)
- Dawei Fan
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China.
| | - Jing Luo
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Zhengxing Gong
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Jiali Niu
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Huan Wang
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Dan Wu
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China
| | - Qin Wei
- Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detection, Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
| |
Collapse
|
9
|
Wang X, Zhu X, Shi X, Zhou Y, Chai Y, Yuan R. Electrostatic Interaction-Induced Aggregation-Induced Emission-Type AgAu Bimetallic Nanoclusters as a Highly Efficient Electrochemiluminescence Emitter for Ultrasensitive Detection of Glial Fibrillary Acidic Protein. Anal Chem 2023; 95:3452-3459. [PMID: 36719845 DOI: 10.1021/acs.analchem.2c05209] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Herein, the aggregation-induced emission (AIE)-type carboxymethyl chitosan (CMCS)@6-aza-2-thiothymine (ATT) templated AgAu bimetallic nanoclusters (CMCS@ATT-AgAu BMNCs) with superior electrochemiluminescence (ECL) emission were first synthesized to construct a biosensor for the ultrasensitive detection of glial fibrillary acidic protein (GFAP). Impressively, unlike the traditional AIE-type bimetallic nanoclusters (BMNCs) obtained by complicated multi-step synthesis, the AIE-type CMCS@ATT-AgAu BMNCs were prepared by the electrostatic interaction between the negatively charged ATT and positively charged CMCS, in which the molecule ATT was served as a capping and reducing agent of bimetal ions. In addition, a rapidly moving cholesterol labeled DNA walker was constructed to move freely on the lipid bilayer to increase its moving efficiency, and the well-regulated DNA was intelligently designed to further improve its walking efficiency for rapid and ultrasensitive detection of GFAP with a limit of detection (LOD) as low as 73 ag/mL. This strategy proposed an avenue to synthesize highly efficient BMNCs-based ECL emitters, which have great potential in ultrasensitive biosensing for early diagnosis of diseases.
Collapse
Affiliation(s)
- Xiaofeng Wang
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, P. R China
| | - Xiaochun Zhu
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, P. R China
| | - Xiaoyu Shi
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, P. R China
| | - Ying Zhou
- College of Food Science, Chongqing Key Laboratory of Speciality Food Co-Built by Sichuan and Chongqing, Southwest University, Chongqing400715, P. R. China
| | - Yaqin Chai
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, P. R China
| | - Ruo Yuan
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, P. R China
| |
Collapse
|
10
|
MXene-mediated in situ formation of Schottky junction for selective and sensitive detection of antioxidant tertiary butylhydroquinone in edible oil. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|