1
|
Li Q, Qi P, Wang Y, Fu S, Zhang H, Li S, Wang L, He C, Chen S, Hou P. Rapid-response near-infrared fluorescence probe for colorimetric detection of HClO and its applications in environmental monitoring and biological imaging. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 320:124613. [PMID: 38865887 DOI: 10.1016/j.saa.2024.124613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 05/27/2024] [Accepted: 06/05/2024] [Indexed: 06/14/2024]
Abstract
As a crucial endogenous reactive oxygen species, hypochlorous acid (HClO) plays an indispensable role in numerous physiological and pathological processes. Additionally, it serves as a biomarker closely associated with inflammation and liver injury. The utilization of near-infrared fluorescence probes has surged in recent years for live biological imaging, owing to their minimal tissue damage and potent tissue penetration capabilities. In this work, a novel near-infrared fluorescence probe MB-HPD was synthesized to sensitively detect HClO. Probe MB-HPD exhibits remarkable selectivity, high sensitivity (14.3 nM), and rapid response towards HClO (20 s). Probe MB-HPD has demonstrated successful application in the imaging of HClO within cells and zebrafish. Remarkably, it has proven to be effective for detecting HClO within environmental samples, as well as imaging HClO in mice models of arthritis and APAP-induced liver injury. These findings indicate the broad applicability of probe MB-HPD, offering a promising avenue for designing highly selective near-infrared fluorescence probes suitable for real-time HClO monitoring.
Collapse
Affiliation(s)
- Qi Li
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Pengfei Qi
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Yaoyao Wang
- Department of Medical Technology, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Shuang Fu
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Hongguang Zhang
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Shuang Li
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Luan Wang
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Chuan He
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Song Chen
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China
| | - Peng Hou
- College of Pharmacy, Qiqihar Medical University, Qiqihar 161006, PR China.
| |
Collapse
|
2
|
Liang Y, Zhang C, Meng Z, Gong S, Tian J, Li R, Wang Z, Wang S. In-situ evaluation the fluctuation of hypochlorous acid in acute liver injury mice models with a mitochondria-targeted NIR ratiometric fluorescent probe. Talanta 2024; 277:126355. [PMID: 38838563 DOI: 10.1016/j.talanta.2024.126355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 04/27/2024] [Accepted: 06/02/2024] [Indexed: 06/07/2024]
Abstract
Acute liver injury (ALI) is a frequent and devastating liver disease that has been made more prevalent by the excessive use of chemicals, drugs, and alcohol in modern life. Hypochlorous acid (HClO), an important biomarker of oxidative stress originating mainly from the mitochondria, has been shown to be intimately connected to the development and course of ALI. Herein, a novel BODIPY-based NIR ratiometric fluorescent probe Mito-BS was constructed for the specific recognition of mitochondrial HClO. The probe Mito-BS can rapidly respond to HClO within 20 s with a ratiometric fluorescence response (from 680 nm to 645 nm), 24-fold fluorescence intensity ratio enhancement (I645/I680), a wide pH adaptation range (5-9) and the low detection limit (31 nM). The probe Mito-BS has been effectively applied to visualize endogenous and exogenous HClO fluctuations in living zebrafish and cells based on its low cytotoxicity and prominent mitochondria-targeting ability. Furthermore, the fluorescent probe Mito-BS makes it possible to achieve the non-invasive in-situ diagnosis of ALI through in mice, and provides a feasible strategy for early diagnosis and drug therapy of ALI and its complications.
Collapse
Affiliation(s)
- Yueyin Liang
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China
| | - Chunjie Zhang
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China
| | - Zhiyuan Meng
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China
| | - Shuai Gong
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China
| | - Jixiang Tian
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China
| | - Ruoming Li
- School of Chemical Engineering & Pharmacy, Wuhan Institute of Technology, Wuhan, 430205, China.
| | - Zhonglong Wang
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China.
| | - Shifa Wang
- Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, International Innovation Center for Forest Chemicals and Materials, College of Chemical Engineering, Nanjing Forestry University, Nanjing, 210037, China.
| |
Collapse
|
3
|
Gao Y, Fan C, Gao J, Yang X, Wang X, Li F, Zhou J, Yu H, Huang Y, Shan Y, Chen L. Dicyanoisophorone-based near-infrared fluorescent probe with large Stokes shift for the monitoring and bioimaging of hypochlorite. Talanta 2024; 274:126063. [PMID: 38599124 DOI: 10.1016/j.talanta.2024.126063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 03/26/2024] [Accepted: 04/04/2024] [Indexed: 04/12/2024]
Abstract
Hypochlorite (ClO-), as one of reactive oxygen species (ROS), is closely linked to various illnesses and is essential for the proper functioning of immune system. Hence, monitoring and assessing ClO- levels in organisms are extremely important for the clinical diagnosis of ClO--related disorders. In this study, a novel ClO--selective fluorescent probe, DCP-ClO, was synthesized with dicyanoisophorone-xanthene unit as parent fluorophore, which displayed excellent selectivity towards ClO-, near-infrared emission (755 nm), large Stokes shift (100 nm), real-time response to ClO-, high sensitivity (LOD = 3.95 × 10-8 M), and low cytotoxicity. The recognition mechanism of DCP-ClO towards ClO- was confirmed to be a typical ICT process by HPLC-MS, HR-MS, 1H NMR and theoretical calculations. Meanwhile, DCP-ClO demonstrated remarkable efficacy in monitoring ClO- levels in water samples and eye-catching ability in imaging endogenous/exogenous ClO- in living organisms, which verified its potential as a powerful tool for the recognition of ClO- in complex biological systems.
Collapse
Affiliation(s)
- Yingkai Gao
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Chuanfeng Fan
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Jian Gao
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Xintong Yang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Xiaochun Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China; School of Chemistry and Life Science, Anshan Normal University, Liaoning Key Laboratory of Development and Utilization for Natural Products Active Molecules, Anshan, 114007, China.
| | - Fei Li
- Biomedical Analysis Center, Army Medical University, Chongqing, 400038, China
| | - Jin Zhou
- School of Pharmacy, Weifang Medical University, Weifang, 261053, China
| | - Haifeng Yu
- College of Chemistry, Baicheng Normal University, Baicheng, 137000, China
| | - Yi Huang
- Biomedical Analysis Center, Army Medical University, Chongqing, 400038, China
| | - Yingying Shan
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| | - Li Chen
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Provincial Key Laboratory of Biochemical Engineering, Qingdao Nucleic Acid Rapid Detection Engineering Research Center, College of Marine Science and Biological Engineering, Qingdao University of Science and Technology, Qingdao, 266042, China
| |
Collapse
|
4
|
Gao C, Chen DD, Zhang L, Ma ML, Liu HW, Cui HR. A Mitochondria-Targeting Fluorescent Probe for the Dual Sensing of Hypochlorite and Viscosity without Signal Crosstalk in Living Cells and Zebrafish. Molecules 2024; 29:3059. [PMID: 38999010 PMCID: PMC11243143 DOI: 10.3390/molecules29133059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 06/23/2024] [Accepted: 06/24/2024] [Indexed: 07/14/2024] Open
Abstract
Hypochlorite (ClO-) and viscosity both affect the physiological state of mitochondria, and their abnormal levels are closely related to many common diseases. Therefore, it is vitally important to develop mitochondria-targeting fluorescent probes for the dual sensing of ClO- and viscosity. Herein, we have explored a new fluorescent probe, XTAP-Bn, which responds sensitively to ClO- and viscosity with off-on fluorescence changes at 558 and 765 nm, respectively. Because the emission wavelength gap is more than 200 nm, XTAP-Bn can effectively eliminate the signal crosstalk during the simultaneous detection of ClO- and viscosity. In addition, XTAP-Bn has several advantages, including high selectivity, rapid response, good water solubility, low cytotoxicity, and excellent mitochondrial-targeting ability. More importantly, probe XTAP-Bn is successfully employed to monitor the dynamic change in ClO- and viscosity levels in the mitochondria of living cells and zebrafish. This study not only provides a reliable tool for identifying mitochondrial dysfunction but also offers a potential approach for the early diagnosis of mitochondrial-related diseases.
Collapse
Affiliation(s)
- Chao Gao
- Synergy Innovation Centre of Biological Peptide Antidiabetics of Hubei Province, College of Life Science, Wuchang University of Technology, Wuhan 430223, China
| | - Dan-Dan Chen
- Synergy Innovation Centre of Biological Peptide Antidiabetics of Hubei Province, College of Life Science, Wuchang University of Technology, Wuhan 430223, China
| | - Lin Zhang
- Synergy Innovation Centre of Biological Peptide Antidiabetics of Hubei Province, College of Life Science, Wuchang University of Technology, Wuhan 430223, China
| | - Ming-Lan Ma
- Synergy Innovation Centre of Biological Peptide Antidiabetics of Hubei Province, College of Life Science, Wuchang University of Technology, Wuhan 430223, China
| | - Hu-Wei Liu
- Synergy Innovation Centre of Biological Peptide Antidiabetics of Hubei Province, College of Life Science, Wuchang University of Technology, Wuhan 430223, China
| | - Hai-Rong Cui
- Synergy Innovation Centre of Biological Peptide Antidiabetics of Hubei Province, College of Life Science, Wuchang University of Technology, Wuhan 430223, China
| |
Collapse
|
5
|
Kondengadan SM, Wang B. Quantitative Factors Introduced in the Feasibility Analysis of Reactive Oxygen Species (ROS)-Sensitive Triggers. Angew Chem Int Ed Engl 2024; 63:e202403880. [PMID: 38630918 PMCID: PMC11192588 DOI: 10.1002/anie.202403880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 04/11/2024] [Accepted: 04/16/2024] [Indexed: 04/19/2024]
Abstract
Reactive oxygen species (ROS) are critical for cellular signaling. Various pathophysiological conditions are also associated with elevated levels of ROS. Hence, ROS-sensitive triggers have been extensively used for selective payload delivery. Such applications are predicated on two key functions: (1) a sufficient magnitude of concentration difference for the interested ROS between normal tissue/cells and intended sites and (2) appropriate reaction kinetics to ensure a sufficient level of selectivity for payload release. Further, ROS refers to a group of species with varying reactivity, which should not be viewed as a uniform group. In this review, we critically analyze data on the concentrations of different ROS species under various pathophysiological conditions and examine how reaction kinetics affect the success of ROS-sensitive linker chemistry. Further, we discuss different ROS linker chemistry in the context of their applications in drug delivery and imaging. This review brings new insights into research in ROS-triggered delivery, highlights factors to consider in maximizing the chance for success and discusses pitfalls to avoid.
Collapse
Affiliation(s)
- Shameer M. Kondengadan
- Department of Chemistry and Center for Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, USA
| | - Binghe Wang
- Department of Chemistry and Center for Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, USA
| |
Collapse
|
6
|
Wang S, Gai L, Chen Y, Ji X, Lu H, Guo Z. Mitochondria-targeted BODIPY dyes for small molecule recognition, bio-imaging and photodynamic therapy. Chem Soc Rev 2024; 53:3976-4019. [PMID: 38450547 DOI: 10.1039/d3cs00456b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2024]
Abstract
Mitochondria are essential for a diverse array of biological functions. There is increasing research focus on developing efficient tools for mitochondria-targeted detection and treatment. BODIPY dyes, known for their structural versatility and excellent spectroscopic properties, are being actively explored in this context. Numerous studies have focused on developing innovative BODIPYs that utilize optical signals for imaging mitochondria. This review presents a comprehensive overview of the progress made in this field, aiming to investigate mitochondria-related biological events. It covers key factors such as design strategies, spectroscopic properties, and cytotoxicity, as well as mechanism to facilitate their future application in organelle imaging and targeted therapy. This work is anticipated to provide valuable insights for guiding future development and facilitating further investigation into mitochondria-related biological sensing and phototherapy.
Collapse
Affiliation(s)
- Sisi Wang
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology of Ministry of Education, and Key Laboratory of Organosilicon Material Technology of Zhejiang Province, Hangzhou Normal University, Hangzhou, 311121, China.
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China.
- State Key Laboratory of Powder Metallurgy, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
| | - Lizhi Gai
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology of Ministry of Education, and Key Laboratory of Organosilicon Material Technology of Zhejiang Province, Hangzhou Normal University, Hangzhou, 311121, China.
| | - Yuncong Chen
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China.
| | - Xiaobo Ji
- State Key Laboratory of Powder Metallurgy, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China
| | - Hua Lu
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology of Ministry of Education, and Key Laboratory of Organosilicon Material Technology of Zhejiang Province, Hangzhou Normal University, Hangzhou, 311121, China.
| | - Zijian Guo
- State Key Laboratory of Coordination Chemistry, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China.
| |
Collapse
|
7
|
Han T, Sun Y, Zhao C, Wang HY, Yu H, Liu Y. Mitochondrial-Targeted Ratiometric Near-Infrared Fluorescence Probe for Monitoring Nitric Oxide in Rheumatoid Arthritis. J Med Chem 2024; 67:4026-4035. [PMID: 38359302 DOI: 10.1021/acs.jmedchem.3c02344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
Rheumatoid arthritis (RA) is a destructive autoimmune disease, where nitric oxide (NO) is closely implicated in the inflammatory processes of RA. Therefore, direct visualization of NO is essential to assess the pathological changes in RA. Herein, a mitochondrial-targeted near-infrared ratiometric fluorescent probe (NFL-NH2), based on the intramolecular charge transfer effect, was synthesized and applied to monitor the changes of NO content in early RA. Specially, probe NFL-NH2 showed a 44-fold fluorescent intensity ratio (I705/I780) response toward NO with a detection limit of 0.536 nM, enabling qualitative and quantitative analysis of NO. Additionally, NFL-NH2 can accurately target mitochondria and sensitively detect exogenous and endogenous NO in RAW 264.7 cells. Notably, in vivo RA monitoring assays demonstrated that NFL-NH2 can rapidly detect NO levels associated with the inflammatory damage degree in RA mice models by ratiometric fluorescence imaging. These results validate that NFL-NH2 holds significant potential for diagnosing NO-mediated RA diseases.
Collapse
Affiliation(s)
- Tingting Han
- School of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Ye Sun
- School of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Chao Zhao
- School of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Hai-Yan Wang
- School of Mechanical Engineering, Southeast University, Nanjing 211189, China
| | - Hui Yu
- School of Engineering, China Pharmaceutical University, Nanjing 211198, China
| | - Yi Liu
- School of Engineering, China Pharmaceutical University, Nanjing 211198, China
| |
Collapse
|
8
|
Fang J, Li X, Gao C, Gao S, Li W, Seidu MA, Zhou H. A unique phenothiazine-based fluorescent probe using benzothiazolium as a reactivity regulator for the specific detection of hypochlorite in drinking water and living organisms. Talanta 2024; 268:125299. [PMID: 37832451 DOI: 10.1016/j.talanta.2023.125299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 10/03/2023] [Accepted: 10/06/2023] [Indexed: 10/15/2023]
Abstract
As a common disinfectant and an essential reactive oxygen species (ROS), hypochlorite (ClO-) plays vital roles in both water treatment and cell metabolism, but its abnormal level can cause serious harm to human health. Therefore, quantifying ClO- level in drinking water and living organisms is extremely significant. Herein, we decorated different cationic heterocycles on phenothiazine core to construct three fluorescent probes for ClO-. According to the results, only benzothiazolium moiety reasonably adjusted the electron cloud density at sulfur atom of phenothiazine core for the specific oxidation with ClO-, thus endowing the prepared probe PT-BT with a perfect selectivity for ClO-. Meanwhile, PT-BT exhibited a low detection limit (38 nM) and a fast response (within 20 s) toward ClO-. Furthermore, this probe was utilized to fabricate a ready-to-use test strip, which could quantitatively measure ClO- level in real water samples by a portable smartphone sensing platform. Notably, PT-BT targeted mitochondria efficiently, and successfully visualized endogenous ClO- in living cells and zebrafish larvae. Especially, PT-BT was able to monitor the dynamic change of ClO- level in inflammatory mice. These results strongly manifested that probe PT-BT was a promising tool for detecting ClO- in drinking water and living organisms.
Collapse
Affiliation(s)
- Jie Fang
- Hubei Key Laboratory of Biomass Fibers and Eco-dyeing & Finishing, Department of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan, 430073, Hubei Province, China
| | - Xiang Li
- Hubei Key Laboratory of Biomass Fibers and Eco-dyeing & Finishing, Department of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan, 430073, Hubei Province, China
| | - Chao Gao
- Hubei Key Laboratory of Biomass Fibers and Eco-dyeing & Finishing, Department of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan, 430073, Hubei Province, China.
| | - Shihao Gao
- Hubei Key Laboratory of Biomass Fibers and Eco-dyeing & Finishing, Department of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan, 430073, Hubei Province, China
| | - Wei Li
- Hubei Key Laboratory of Biomass Fibers and Eco-dyeing & Finishing, Department of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan, 430073, Hubei Province, China.
| | - Mohammed Awal Seidu
- Hubei Key Laboratory of Biomass Fibers and Eco-dyeing & Finishing, Department of Chemistry and Chemical Engineering, Wuhan Textile University, Wuhan, 430073, Hubei Province, China
| | - Hongjun Zhou
- Changzhi Medical College, Changzhi, 046000, Shanxi Province, China; Shanxi Zhendong Pharmaceutical Co. Ltd., Changzhi, 046000, Shanxi Province, China.
| |
Collapse
|
9
|
Li S, Wang P, Yang K, Liu Y, Cheng D, He L. Construction of HClO activated near-infrared fluorescent probe for imaging hepatocellular carcinoma. Anal Chim Acta 2023; 1252:341009. [PMID: 36935131 DOI: 10.1016/j.aca.2023.341009] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 02/20/2023] [Accepted: 02/23/2023] [Indexed: 03/05/2023]
Abstract
Hepatocellular carcinoma (HCC) is one of the most common malignancies in the liver with poor prognosis. In order to improve the prognosis and overall survival of patients with HCC, it is important to identify it at early stage and resect it precisely. Cell microenvironment, active compounds, and enzymes may change during the cancerization of hepatocytes. Hypochlorous acid (HClO), one of the most significant signal molecules in the cellular signaling pathway, plays an important role in many cellular processes. To detect and treat liver cancers, it is imperative to study how HClO levels change in hepatocytes. However, developing fluorescent probes specific to liver cells to detect HClO still challenging. Herein, we designed and synthesized a NIR hepatocyte-specific fluorescent probe (MBH-MT) that displayed excellent optical properties for detecting HClO in biological samples. Cell imaging experiment conducted with the unique probe MBH-MT, showed that the biocompatible sensor is capable of monitoring HClO and distinguishing normal cells from cancer cells (e.g., HepG2, HUVEC, RAW264.7, L02 and HK-2 cells). An organ imaging experiment with the probe MBH-MT demonstrated its effectiveness in diagnosing and imaging hepatocellular carcinoma in vivo. MBH-MT's in situ imaging also demonstrated that it can target and image mouse hepatocellular carcinomas. Furthermore, MBH-MT has also successfully been used to diagnose and guide liver cancer surgery early. In the future, we expect that this powerful tool may be help in the detection and imaging of hepatocellular carcinoma, which may affect a large number of people.
Collapse
Affiliation(s)
- Songjiao Li
- Hunan Provincial Key Laboratory of Tumor Microenvironment Responsive Drug Research, Hunan Province Cooperative Innovation Center for Molecular Target New Drug Study, Cancer Research Institute, Department of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, Hengyang, 421001, PR China
| | - Peipei Wang
- Hunan Provincial Key Laboratory of Tumor Microenvironment Responsive Drug Research, Hunan Province Cooperative Innovation Center for Molecular Target New Drug Study, Cancer Research Institute, Department of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, Hengyang, 421001, PR China
| | - Ke Yang
- Hunan Provincial Key Laboratory of Tumor Microenvironment Responsive Drug Research, Hunan Province Cooperative Innovation Center for Molecular Target New Drug Study, Cancer Research Institute, Department of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, Hengyang, 421001, PR China
| | - Ying Liu
- Hunan Provincial Key Laboratory of Tumor Microenvironment Responsive Drug Research, Hunan Province Cooperative Innovation Center for Molecular Target New Drug Study, Cancer Research Institute, Department of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, Hengyang, 421001, PR China
| | - Dan Cheng
- Clinical Research Institute, The Affiliated Nanhua Hospital, Hengyang Medical School, University of South China, Hengyang, China.
| | - Longwei He
- Hunan Provincial Key Laboratory of Tumor Microenvironment Responsive Drug Research, Hunan Province Cooperative Innovation Center for Molecular Target New Drug Study, Cancer Research Institute, Department of Pharmacy and Pharmacology, Hengyang Medical School, University of South China, Hengyang, 421001, PR China.
| |
Collapse
|
10
|
Afshari MJ, Cheng X, Duan G, Duan R, Wu S, Zeng J, Gu Z, Gao M. Vision for Ratiometric Nanoprobes: In Vivo Noninvasive Visualization and Readout of Physiological Hallmarks. ACS NANO 2023; 17:7109-7134. [PMID: 37036400 DOI: 10.1021/acsnano.3c01641] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Lesion areas are distinguished from normal tissues surrounding them by distinct physiological characteristics. These features serve as biological hallmarks with which targeted biomedical imaging of the lesion sites can be achieved. Although tremendous efforts have been devoted to providing smart imaging probes with the capability of visualizing the physiological hallmarks at the molecular level, the majority of them are merely able to derive anatomical information from the tissues of interest, and thus are not suitable for taking part in in vivo quantification of the biomarkers. Recent advances in chemical construction of advanced ratiometric nanoprobes (RNPs) have enabled a horizon for quantitatively monitoring the biological abnormalities in vivo. In contrast to the conventional probes whose dependency of output on single-signal profiles restricts them from taking part in quantitative practices, RNPs are designed to provide information in two channels, affording a self-calibration opportunity to exclude the analyte-independent factors from the outputs and address the issue. Most of the conventional RNPs have encountered several challenges regarding the reliability and sufficiency of the obtained data for high-performance imaging. In this Review, we have summarized the recent progresses in developing highly advanced RNPs with the capabilities of deriving maximized information from the lesion areas of interest as well as adapting themselves to the complex biological systems in order to minimize microenvironmental-induced falsified signals. To provide a better outlook on the current advanced RNPs, nanoprobes based on optical, photoacoustic, and magnetic resonance imaging modalities for visualizing a wide range of analytes such as pH, reactive species, and different derivations of amino acids have been included. Furthermore, the physicochemical properties of the RNPs, the major constituents of the nanosystems and the analyte recognition mechanisms have been introduced. Moreover, the alterations in the values of the ratiometric signal in response to the analyte of interest as well as the time at which the highest value is achieved, have been included for most of RNPs discussed in this Review. Finally, the challenges as well as future perspectives in the field are discussed.
Collapse
Affiliation(s)
- Mohammad Javad Afshari
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Xiaju Cheng
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Guangxin Duan
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Ruixue Duan
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Shuwang Wu
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Jianfeng Zeng
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| | - Zi Gu
- School of Chemical Engineering and Australian Centre for NanoMedicine (ACN), University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Mingyuan Gao
- Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Soochow University, Suzhou 215123, People's Republic of China
| |
Collapse
|
11
|
Shangguan L, Qian X, Wu Z, Han T, Sun W, Liu L, Liu Y. A ratiometric nanoprobe for the in vivo bioimaging of hypochlorous acid to detect drug-damaged liver and kidneys. Analyst 2023; 148:762-771. [PMID: 36648506 DOI: 10.1039/d2an01977a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
As the organs responsible for toxin transformation and excretion in the body, damage to the liver and kidneys induced by inevitable drug toxicity is the main cause of acute liver and kidney injury. P-Acetamidophenol overdose leads hypochlorous acid (HClO) to accumulate in the mitochondria of tissues, ultimately resulting in acute liver and kidney injury in humans, despite its clinical use as an antipyretic medicine. Herein, we report an HClO-activatable self-assembling ratiometric nanoprobe NRH-800-PEG for screening the upregulation of HClO by colocalization in mitochondria while monitoring the changes in the endogenous HClO levels in cells with ratiometric signals. Furthermore, NRH-800-PEG was constructed to evaluate injury by fluorescence ratio imaging in the tissues of inflammatory mice. Our strategy offers a novel tool for assessing disease progression during drug-induced liver and kidney injury.
Collapse
Affiliation(s)
- Lina Shangguan
- Clinical Laboratory, Xiantao First People's Hospital, Xiantao, 433000, China. .,School of Engineering, China Pharmaceutical University, Nanjing, 211198, China.
| | - Xiaoli Qian
- School of Engineering, China Pharmaceutical University, Nanjing, 211198, China.
| | - Zhuoyang Wu
- School of Engineering, China Pharmaceutical University, Nanjing, 211198, China.
| | - Tingting Han
- School of Engineering, China Pharmaceutical University, Nanjing, 211198, China.
| | - Wanlu Sun
- School of Engineering, China Pharmaceutical University, Nanjing, 211198, China.
| | - Li Liu
- Clinical Laboratory, Xiantao First People's Hospital, Xiantao, 433000, China.
| | - Yi Liu
- School of Engineering, China Pharmaceutical University, Nanjing, 211198, China.
| |
Collapse
|