1
|
Kelly JT, McNamara LE, Hoover ME, Rubenstein HM, Houthuijs K, Martens J. Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands' Passive Sampling. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:829-833. [PMID: 38564189 DOI: 10.1021/jasms.3c00400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
A new approach using orthogonal analytical techniques is developed for chemical identification. High resolution mass spectrometry and infrared ion spectroscopy are applied through a 5-level confidence paradigm to demonstrate the effectiveness of nontargeted workflow for the identification of hazardous organophosphates. Triphenyl phosphate is used as a surrogate organophosphate for occupational exposure, and silicone wristbands are used to represent personal samplers. Spectral data of a target compound is combined with spectral data of the sodium adduct and quantum chemical calculations to achieve a confirmed identification. Here, we demonstrate a nontargeted workflow that identifies organophosphate exposure and provides a mechanism for selecting validated methods for quantitative analyses.
Collapse
Affiliation(s)
- John T Kelly
- Savannah River National Laboratory, 301 Gateway Drive, Aiken, South Carolina 29803, United States
| | - Louis E McNamara
- Savannah River National Laboratory, 301 Gateway Drive, Aiken, South Carolina 29803, United States
| | - Megan E Hoover
- Savannah River National Laboratory, 301 Gateway Drive, Aiken, South Carolina 29803, United States
| | - H Mitchell Rubenstein
- United States Air Force - Air Force Research Laboratory, 711th Human Performance Wing, 2510 Fifth Street, Area B, Building 840, Wright-Patterson AFB, Ohio 45433, United States
| | - Kas Houthuijs
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7c, 6525ED Nijmegen, The Netherlands
| | - Jonathan Martens
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7c, 6525ED Nijmegen, The Netherlands
| |
Collapse
|
2
|
Vink MA, Alarcan J, Martens J, Buma WJ, Braeuning A, Berden G, Oomens J. Structural Elucidation of Agrochemical Metabolic Transformation Products Based on Infrared Ion Spectroscopy to Improve In Silico Toxicity Assessment. Chem Res Toxicol 2024; 37:81-97. [PMID: 38118149 PMCID: PMC10792670 DOI: 10.1021/acs.chemrestox.3c00316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 12/03/2023] [Accepted: 12/05/2023] [Indexed: 12/22/2023]
Abstract
Toxicological assessments of newly developed agrochemical agents consider chemical modifications and their metabolic and biotransformation products. To carry out an in silico hazard assessment, understanding the type of chemical modification and its location on the original compound can greatly enhance the reliability of the evaluation. Here, we present and apply a method based on liquid chromatography-mass spectrometry (LC-MS) enhanced with infrared ion spectroscopy (IRIS) to better delineate the molecular structures of transformation products before in silico toxicology evaluation. IRIS facilitates the recording of IR spectra directly in the mass spectrometer for features selected by retention time and mass-to-charge ratio. By utilizing quantum-chemically predicted IR spectra for candidate molecular structures, one can either derive the actual structure or significantly reduce the number of (isomeric) candidate structures. This approach can assist in making informed decisions. We apply this method to a plant growth stimulant, digeraniol sinapoyl malate (DGSM), that is currently under development. Incubation of the compound in Caco-2 and HepaRG cell lines in multiwell plates and analysis by LC-MS reveals oxidation, glucuronidation, and sulfonation metabolic products, whose structures were elucidated by IRIS and used as input for an in silico toxicology assessment. The toxicity of isomeric metabolites predicted by in silico tools was also assessed, which revealed that assigning the right metabolite structure is an important step in the overall toxicity assessment of the agrochemical. We believe this identification approach can be advantageous when specific isomers are significantly more hazardous than others and can help better understand metabolic pathways.
Collapse
Affiliation(s)
- Matthias
J. A. Vink
- Institute
for Molecules and Materials, FELIX Laboratory, Radboud University, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands
| | - Jimmy Alarcan
- Department
of Food Safety, German Federal Institute
for Risk Assessment, Max-Dohrn-Str. 8-10, 10589 Berlin, Germany
| | - Jonathan Martens
- Institute
for Molecules and Materials, FELIX Laboratory, Radboud University, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands
| | - Wybren Jan Buma
- Institute
for Molecules and Materials, FELIX Laboratory, Radboud University, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands
- van’t
Hoff Institute for Molecular Sciences, University
of Amsterdam, Science
Park 904, 1098 XH Amsterdam, The Netherlands
| | - Albert Braeuning
- Department
of Food Safety, German Federal Institute
for Risk Assessment, Max-Dohrn-Str. 8-10, 10589 Berlin, Germany
| | - Giel Berden
- Institute
for Molecules and Materials, FELIX Laboratory, Radboud University, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands
| | - Jos Oomens
- Institute
for Molecules and Materials, FELIX Laboratory, Radboud University, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands
- van’t
Hoff Institute for Molecular Sciences, University
of Amsterdam, Science
Park 904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
3
|
Houthuijs KJ, Horn M, Vughs D, Martens J, Brunner AM, Oomens J, Berden G. Identification of organic micro-pollutants in surface water using MS-based infrared ion spectroscopy. CHEMOSPHERE 2023; 341:140046. [PMID: 37660788 DOI: 10.1016/j.chemosphere.2023.140046] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/29/2023] [Accepted: 08/31/2023] [Indexed: 09/05/2023]
Abstract
Comprehensive monitoring of organic micro-pollutants (OMPs) in drinking water sources relies on non-target screening (NTS) using liquid-chromatography and high-resolution mass spectrometry (LC-HRMS). Identification of OMPs is typically based on accurate mass and tandem mass spectrometry (MS/MS) data by matching against entries in compound databases and MS/MS spectral libraries. MS/MS spectra are, however, not always diagnostic for the full molecular structure and, moreover, emerging OMPs or OMP transformation products may not be present in libraries. Here we demonstrate how infrared ion spectroscopy (IRIS), an emerging MS-based method for structural elucidation, can aid in the identification of OMPs. IRIS measures the IR spectrum of an m/z-isolated ion in a mass spectrometer, providing an orthogonal diagnostic for molecular identification. Here, we demonstrate the workflow for identification of OMPs in river water and show how quantum-chemically predicted IR spectra can be used to screen potential candidates and suggest structural assignments. A crucial step herein is to define a set of candidate structures, presumably including the actual OMP, for which we present several strategies based on domain knowledge, the IR spectrum and MS/MS spectrum.
Collapse
Affiliation(s)
- Kas J Houthuijs
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED, Nijmegen, the Netherlands
| | - Marijke Horn
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED, Nijmegen, the Netherlands
| | - Dennis Vughs
- KWR Water Research Institute, Chemical Water Quality and Health, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands
| | - Jonathan Martens
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED, Nijmegen, the Netherlands
| | - Andrea M Brunner
- KWR Water Research Institute, Chemical Water Quality and Health, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; TNO, Environmental Modelling, Sensing and Analysis (EMSA), Princetonlaan 8, 3584 CB, Utrecht, the Netherlands
| | - Jos Oomens
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED, Nijmegen, the Netherlands; van't Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH, Amsterdam, the Netherlands
| | - Giel Berden
- Radboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED, Nijmegen, the Netherlands.
| |
Collapse
|
4
|
Houthuijs KJ, Berden G, Engelke UFH, Gautam V, Wishart DS, Wevers RA, Martens J, Oomens J. An In Silico Infrared Spectral Library of Molecular Ions for Metabolite Identification. Anal Chem 2023. [PMID: 37262385 DOI: 10.1021/acs.analchem.3c01078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Infrared ion spectroscopy (IRIS) continues to see increasing use as an analytical tool for small-molecule identification in conjunction with mass spectrometry (MS). The IR spectrum of an m/z selected population of ions constitutes a unique fingerprint that is specific to the molecular structure. However, direct translation of an IR spectrum to a molecular structure remains challenging, as reference libraries of IR spectra of molecular ions largely do not exist. Quantum-chemically computed spectra can reliably be used as reference, but the challenge of selecting the candidate structures remains. Here, we introduce an in silico library of vibrational spectra of common MS adducts of over 4500 compounds found in the human metabolome database. In total, the library currently contains more than 75,000 spectra computed at the DFT level that can be queried with an experimental IR spectrum. Moreover, we introduce a database of 189 experimental IRIS spectra, which is employed to validate the automated spectral matching routines. This demonstrates that 75% of the metabolites in the experimental data set are correctly identified, based solely on their exact m/z and IRIS spectrum. Additionally, we demonstrate an approach for specifically identifying substructures by performing a search without m/z constraints to find structural analogues. Such an unsupervised search paves the way toward the de novo identification of unknowns that are absent in spectral libraries. We apply the in silico spectral library to identify an unknown in a plasma sample as 3-hydroxyhexanoic acid, highlighting the potential of the method.
Collapse
Affiliation(s)
- Kas J Houthuijs
- Institute for Molecules and Materials, FELIX Laboratory, Radboud University, Nijmegen 6525 ED, The Netherlands
| | - Giel Berden
- Institute for Molecules and Materials, FELIX Laboratory, Radboud University, Nijmegen 6525 ED, The Netherlands
| | - Udo F H Engelke
- Department of Genetics, Translational Metabolic Laboratory, Radboud University Medical Center, Nijmegen 6525 GA, The Netherlands
| | - Vasuk Gautam
- Department of Biological Sciences, University of Alberta, Edmonton AB T6G 2E9, Canada
| | - David S Wishart
- Department of Biological Sciences, University of Alberta, Edmonton AB T6G 2E9, Canada
- Department of Computing Science, University of Alberta, Edmonton, AB T6G 2E8, Canada
- Department of Laboratory Medicine and Pathology, University of Alberta, Edmonton, AB T6G 2B7, Canada
- Faculty of Pharmacy and Pharmaceutical Sciences, University of Alberta, Edmonton, AB T6G 2H7, Canada
| | - Ron A Wevers
- Department of Genetics, Translational Metabolic Laboratory, Radboud University Medical Center, Nijmegen 6525 GA, The Netherlands
| | - Jonathan Martens
- Institute for Molecules and Materials, FELIX Laboratory, Radboud University, Nijmegen 6525 ED, The Netherlands
| | - Jos Oomens
- Institute for Molecules and Materials, FELIX Laboratory, Radboud University, Nijmegen 6525 ED, The Netherlands
- van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam 1098 XH, The Netherlands
| |
Collapse
|