1
|
Wang Z, Zhou X, Kong Q, He H, Sun J, Qiu W, Zhang L, Yang M. Extracellular Vesicle Preparation and Analysis: A State-of-the-Art Review. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2401069. [PMID: 38874129 DOI: 10.1002/advs.202401069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 04/11/2024] [Indexed: 06/15/2024]
Abstract
In recent decades, research on Extracellular Vesicles (EVs) has gained prominence in the life sciences due to their critical roles in both health and disease states, offering promising applications in disease diagnosis, drug delivery, and therapy. However, their inherent heterogeneity and complex origins pose significant challenges to their preparation, analysis, and subsequent clinical application. This review is structured to provide an overview of the biogenesis, composition, and various sources of EVs, thereby laying the groundwork for a detailed discussion of contemporary techniques for their preparation and analysis. Particular focus is given to state-of-the-art technologies that employ both microfluidic and non-microfluidic platforms for EV processing. Furthermore, this discourse extends into innovative approaches that incorporate artificial intelligence and cutting-edge electrochemical sensors, with a particular emphasis on single EV analysis. This review proposes current challenges and outlines prospective avenues for future research. The objective is to motivate researchers to innovate and expand methods for the preparation and analysis of EVs, fully unlocking their biomedical potential.
Collapse
Affiliation(s)
- Zesheng Wang
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
- Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Xiaoyu Zhou
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
- Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Qinglong Kong
- The Second Department of Thoracic Surgery, Dalian Municipal Central Hospital, Dalian, 116033, P. R. China
| | - Huimin He
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
- Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Jiayu Sun
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
| | - Wenting Qiu
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
| | - Liang Zhang
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
- Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Mengsu Yang
- Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen Futian Research Institute, Shenzhen, Guangdong, 518000, P. R. China
- Department of Biomedical Sciences, and Tung Biomedical Sciences Centre, City University of Hong Kong, Hong Kong, 999077, P. R. China
- Key Laboratory of Biochip Technology, Biotech and Health Centre, Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| |
Collapse
|
2
|
Li M, Tai Q, Shen S, Gao M, Zhang X. Biomimetic Exosome-Sheathed Magnetic Mesoporous Anchor with Modification of Glucose Oxidase for Synergistic Targeting and Starving Tumor Cells. ACS APPLIED MATERIALS & INTERFACES 2024; 16:29634-29644. [PMID: 38822821 DOI: 10.1021/acsami.4c02337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2024]
Abstract
Efficient protection and precise delivery of biomolecules are of critical importance in the intervention and therapy of various diseases. Although diverse specific marker-functionalized drug carriers have been developed rapidly, current approaches still encounter substantial challenges, including strong immunogenicity, limited target availability, and potential side effects. Herein, we developed a biomimetic exosome-sheathed magnetic mesoporous anchor modified with glucose oxidase (MNPs@mSiO2-GOx@EM) to address these challenges and achieve synergistic targeting and starving of tumor cells. The MNPs@mSiO2-GOx@EM anchor integrated the unique characteristics of different components. An external decoration of exosome membrane (EM) with high biocompatibility contributed to increased phagocytosis prevention, prolonged circulation, and enhanced recognition and cellular uptake of loaded particles. An internal coated magnetic mesoporous core with rapid responsiveness by the magnetic field guidance and large surface area facilitated the enrichment of nanoparticles at the specific site and provided enough space for modification of glucose oxidase (GOx). The inclusion of GOx in the middle layer accelerated the energy-depletion process within cells, ultimately leading to the starvation and death of target cells with minimal side effects. With these merits, in vitro study manifested that our nanoplatform not only demonstrated an excellent targeting capability of 94.37% ± 1.3% toward homotypic cells but also revealed a remarkably high catalytical ability and cytotoxicity on tumor cells. Assisted by the magnetic guidance, the utilization of our anchor obviously inhibits the tumor growth in vivo. Together, our study is promising to serve as a versatile method for the highly efficient delivery of various target biomolecules to intended locations due to the fungibility of exosome membranes and provide a potential route for the recognition and starvation of tumor cells.
Collapse
Affiliation(s)
- Mengran Li
- Department of Chemistry, Fudan University, Shanghai 200433, China
| | - Qunfei Tai
- Department of Chemistry, Fudan University, Shanghai 200433, China
| | - Shun Shen
- Pharmacy Department, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai 201399, China
| | - Mingxia Gao
- Department of Chemistry, Fudan University, Shanghai 200433, China
- Pharmacy Department, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai 201399, China
| | - Xiangmin Zhang
- Department of Chemistry, Fudan University, Shanghai 200433, China
| |
Collapse
|
3
|
Jo G, Yeo WS. Enhanced synthesis of antibody-functionalized gold nanoparticles for multiplexed exosome detection via mass signal amplification in LDI-TOF MS. ANAL SCI 2024:10.1007/s44211-024-00604-9. [PMID: 38780862 DOI: 10.1007/s44211-024-00604-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Accepted: 05/16/2024] [Indexed: 05/25/2024]
Abstract
We present a novel method for sensitive exosomal protein detection using organic matrix-free laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS) and gold nanoparticles (AuNPs) functionalized with mass tags for signal amplification (Am-tags). Target exosomes were captured by specific antibodies on AuNPs and a biochip, where the antibody-presenting AuNPs (Ab/Am-tag@AuNPs) contained excess Am-tags. LDI-TOF MS analysis revealed the mass signal of Am-tags on Ab/Am-tag@AuNPs, indicating the presence of target exosomes. Thus, the target signal was amplified by a large number of Am-tags, resulting in enhanced sensitivity. We optimized the protocol to prepare stable Ab/Am-tag@AuNPs, focusing on parameters such as the concentration and ratio of thiol molecules for AuNP functionalization, suitable solvents for the coupling reaction, and amount of antibodies conjugated to the AuNPs. Subsequently, we evaluated the ability of our method to detect exosomes isolated from three cell lines, NIH3T3, MCF7, and HeLa, using an anti-Rab5 immobilized gold chip and anti-CD63/Am-tag@AuNPs with LDI-TOF MS analysis. Calibration curves constructed for the three cell lines showed a linear relationship with an excellent limit of detection. Finally, we emphasized the versatility of our method for the quantitative detection of exosomal proteins CD63 and mucin 1 (MUC1) using two types of Am-tags. LDI-TOF MS analysis revealed the presence of CD63 and MUC1 at different expression levels in HeLa and MCF7 cancer cells. Our findings clearly indicate the potential of Ab/Am-tag@AuNPs as a sensitive and reliable approach for identifying biomarkers in exosomes, providing valuable insights into their utility in biomedical research and clinical settings.
Collapse
Affiliation(s)
- Gaon Jo
- Department of Bioscience and Biotechnology, Bio/Molecular Informatics Center, Konkuk University, Seoul, 143-701, Korea
| | - Woon-Seok Yeo
- Department of Bioscience and Biotechnology, Bio/Molecular Informatics Center, Konkuk University, Seoul, 143-701, Korea.
| |
Collapse
|
4
|
Wu Y, Gao Z, Chai Y, Zhang A, He S, Liu X, Yuan H, Tan L, Ding L, Wu Y. One-step and label-free ratiometric fluorescence assay for the detection of plasma exosome towards cancer diagnosis. Talanta 2024; 271:125700. [PMID: 38277965 DOI: 10.1016/j.talanta.2024.125700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 01/01/2024] [Accepted: 01/18/2024] [Indexed: 01/28/2024]
Abstract
Exosomes are closely associated with tumor development and are regarded as viable biomarkers for cancer. Here, a ratiometric fluorescence method was proposed for the one-step and label-free detection of plasma exosomes. A bicolor streptavidin magnetic beads were specifically created with an immobilized Cy5-labeled hairpin aptamer for CD63 (Cy5-Apt) on its surface to identify exosome, and a green color SYBR Green I (SGI) embedded in the stem of Cy5-Apt to respond to exosomes. After exosome capture, the Cy5-Apt could undergo a conformational shift and release the encapsulated SGI, allowing exosome measurement based on the fluorescence ratio of Cy5 and SGI. The enrichment, separation and detection of exosomes in proposed method could be completed in one step (30 min), which is a significant improvement over previous method. Furthermore, the use of ratiometric fluorescence and magnetic separation allows for exosome enrichment and interference elimination from complex matrices, improving accuracy and sensitivity. Particularly, the assay could detect exosomes in plasma and has potential to distinguish lung cancer patients from healthy volunteers with an area under the receiver operator characteristic curve of 0.85. Besides, the study provided an efficient method for analyzing the various divisions of exosomes by merely modifying the aptamer, which holds great promise for point-of-care applications.
Collapse
Affiliation(s)
- Yan Wu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Zibo Gao
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China; Department of Epidemiology and Biostatistics, School of Public Health, Jilin University, Changchun, Jilin Province, 130000, China
| | - Yaru Chai
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Aiai Zhang
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Sitian He
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Xia Liu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Huijie Yuan
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Longlong Tan
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China
| | - Lihua Ding
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China.
| | - Yongjun Wu
- College of Public Health, Zhengzhou University, Zhengzhou, 450001, China.
| |
Collapse
|