1
|
Li Y, Li W, Zheng Y, Wang T, Pu R, Zhang Z. Desalting strategies for native mass spectrometry. Talanta 2025; 281:126824. [PMID: 39250868 DOI: 10.1016/j.talanta.2024.126824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 09/02/2024] [Accepted: 09/05/2024] [Indexed: 09/11/2024]
Abstract
In native mass spectrometry (MS) salts are indispensable for preserving the native structures of biomolecules, but detrimental to mass sensitivity, resolution, and accuracy. Such a conflict makes desalting in native MS more challenging, distinctive, and sample-dependent than in peptide-centric MS. This review first briefly introduces the charged residue mechanism whereby native-like gaseous protein ions are released from electrospray droplets, revealing a higher degree of salt adduction than denatured proteins. Subsequently, this review summarizes and explores the existing strategies, underlying mechanisms and future perspectives of desalting in native MS. These strategies mainly focus on buffer exchange into volatile salts (offline and online approaches), addition of solution additives (e.g., anion, supercharging reagent, solution phase chelator and amino acid), use of submicron electrospray emitters (down to 60 nm), and other potential approaches (e.g., induced and electrophoretic nanoelectrospray ionization). The strategies of online buffer exchange and using nanoscale electrospray emitters are highlighted. This review would not only be a valuable addition to the field of sample preparation in MS, but would also serve as a beginner's guide to desalting in native MS.
Collapse
Affiliation(s)
- Yun Li
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, 710065, China
| | - Weijie Li
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, 710065, China
| | - Yajun Zheng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, 710065, China.
| | - Tong Wang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, 710065, China
| | - Ruijin Pu
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, 710065, China
| | - Zhiping Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, 710065, China.
| |
Collapse
|
2
|
Zeng J, Sun K, Chen S, Zhang X, Wang X, Zhang B. A Microfluidic-Fabricated Rod Sprayer for Nanoelectrospray Mass Spectrometry. Anal Chem 2024; 96:3989-3993. [PMID: 38315070 DOI: 10.1021/acs.analchem.3c05695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2024]
Abstract
The nanoelectrosprayer is a key device in the hyphenation of nanoLC-ESI-MS, and its development plays a crucial role in pushing forward the mining depth of biological discovery and industrialization of omics science. In this work, a new type of nanoelectrospray emitter, a rod sprayer, was developed based on microfluidic manufacture. Due to its porous silica structure, the rod sprayer in effect worked as a multinozzle sprayer, which is composed of a bunch of micrometer sized spray channels. Without the need for sophisticated microfabrication equipment, a superclean environment, or a complicated assembling process, such sprayer rods can be facilely fabricated in a mass production style: 3,600 rods with excellent monodispersity have been fabricated in 1 h, and rod sprayers thus made have demonstrated excellent intraday, interday, and interbatch reproducibilities: RSD = 1.9, 4.9, and 6.1%, respectively. The rod sprayer can generate stable electrospray in a wide voltage range from 2.6 to 3.2 kV and flow rates from 50 to 1000 nL/min, covering typical flow rates of subnanoLC, nanoLC, to microLC, and work steadily even under complex matrix environments (e.g., Hank's balanced salt solution containing sodium, magnesium, and calcium ions) without clogging. Meanwhile, the rod sprayers exhibited 200-1800% ionization efficiency enhancement in comparison with commonly used tapered tip emitters, for small molecule drugs, peptides, and proteins, respectively, and provided a broadened linear dynamic range of 4 orders of magnitude. The excellent characteristics of the rod sprayer, together with its small size and mass production capacity, should provide a high quality, high durability, high consistency, and disposable use-supported nanoelectrospray solution for MS-based bioanalyses.
Collapse
Affiliation(s)
- Juxing Zeng
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Kaiyue Sun
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Shiyi Chen
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Xin Zhang
- Anhui Wanyi Science and Technology Co. Ltd, Hefei 230088, China
| | | | - Bo Zhang
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| |
Collapse
|
3
|
Schwenzer AK, Kruse L, Jooß K, Neusüß C. Capillary electrophoresis-mass spectrometry for protein analyses under native conditions: Current progress and perspectives. Proteomics 2024; 24:e2300135. [PMID: 37312401 DOI: 10.1002/pmic.202300135] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 05/16/2023] [Accepted: 05/23/2023] [Indexed: 06/15/2023]
Abstract
Native mass spectrometry is a rapidly emerging technique for fast and sensitive structural analysis of protein constructs, maintaining the protein higher order structure. The coupling with electromigration separation techniques under native conditions enables the characterization of proteoforms and highly complex protein mixtures. In this review, we present an overview of current native CE-MS technology. First, the status of native separation conditions is described for capillary zone electrophoresis (CZE), affinity capillary electrophoresis (ACE), and capillary isoelectric focusing (CIEF), as well as their chip-based formats, including essential parameters such as electrolyte composition and capillary coatings. Further, conditions required for native ESI-MS of (large) protein constructs, including instrumental parameters of QTOF and Orbitrap systems, as well as requirements for native CE-MS interfacing are presented. On this basis, methods and applications of the different modes of native CE-MS are summarized and discussed in the context of biological, medical, and biopharmaceutical questions. Finally, key achievements are highlighted and concluded, while remaining challenges are pointed out.
Collapse
Affiliation(s)
| | - Lena Kruse
- Department of Chemistry, Aalen University, Aalen, Germany
| | - Kevin Jooß
- Department of Chemistry and Molecular Biosciences, the Chemistry of Life Processes Institute, and the Proteomics Center of Excellence, Northwestern University, Evanston, Illinois, USA
- Division of Bioanalytical Chemistry, Amsterdam Institute of Molecular and Life Sciences, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | | |
Collapse
|
4
|
Huang K, Zeng H, Li X, Li X, Pan Y, Gao Y. Arc-Induced Electrospray Ionization Mass Spectrometry. Anal Chem 2024; 96:317-324. [PMID: 38154037 DOI: 10.1021/acs.analchem.3c04125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2023]
Abstract
Arc-induced electrospray ionization mass spectrometry (AESI-MS) was developed during which alternating current electrospray is simply achieved through the arc plasma. The AESI source exploits the arc's temperature and charge properties to generate aerosols consisting of charged microdroplets. The electrospray region, in which organic molecules are contained within microdroplets, partially overlaps with the arc plasma region. Guided by the electric field, these molecules undergo ionization, yielding ionic target analytes. AESI represents a soft ionization method that combines the mechanisms of atmospheric pressure chemical ionization and electrospray ionization, facilitating the ionization of analytes with wide ranging polarities. The precisely targeted spraying area enhances ion entry into the mass analyzer, thereby enabling excellent ionization efficiency. The AESI source exhibits several notable advantages over the electrospray ionization source, including an elevated but comparable level of active species concentrations and types, simplified mass spectra for direct amino acid analysis, high salt tolerance, versatile analysis of compounds with varying polarities, and reliable quantitative analysis of amino acids in complex matrices. Overall, AESI broadens the methodologies employed to generate microdroplets, providing a technological and scientific framework for creating distinctive electrospray ionization techniques.
Collapse
Affiliation(s)
- Kaineng Huang
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Hui Zeng
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Xingyue Li
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Xiaoting Li
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang310027, P. R. China
| | - Yuanji Gao
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, Sichuan 610068, P. R. China
| |
Collapse
|
5
|
Wang T, Li Z, Gao H, Hu J, Chen HY, Xu JJ. Ultrafast C-C and C-N bond formation reactions in water microdroplets facilitated by the spontaneous generation of carbocations. Chem Sci 2023; 14:11515-11520. [PMID: 37886101 PMCID: PMC10599473 DOI: 10.1039/d3sc03870j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 09/24/2023] [Indexed: 10/28/2023] Open
Abstract
Carbocations are important electrophilic intermediates in organic chemistry, but their formation typically requires harsh conditions such as extremely low pH, elevated temperature, strong oxidants and/or expensive noble-metal catalysts. Herein, we report the spontaneous generation of highly reactive carbocations in water microdroplets by simply spraying a diarylmethanol aqueous solution. The formation of transient carbocations as well as their ultrafast in-droplet transformations through carbocation-involved C-C and C-N bond formation reactions are directly characterized by mass spectrometry. The intriguing formation and stabilization of carbocations are attributed to the super acidity of the positively charged water microdroplets as well as the high electric fields at the water-air interfaces. Without the utilization of external acids as catalysts, we believe that these microdroplet reactions would pose a new and sustainable way for the construction of aryl-substituted compounds.
Collapse
Affiliation(s)
- Ting Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| | - Zheng Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| | - Hang Gao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| | - Jun Hu
- School of Life Sciences and Health Engineering, Jiangnan University Wuxi 214122 China
| | - Hong-Yuan Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| | - Jing-Juan Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University Nanjing 210023 P. R. China
| |
Collapse
|
6
|
Hsu CY, Prabhu GRD, Chang CH, Hsu PC, Buchowiecki K, Urban PL. Are Most Micrometer Droplets (>10 μm) Wasted in Electrospray Ionization? An Insight from Real-Time High-Speed Imaging. Anal Chem 2023; 95:14702-14709. [PMID: 37725015 DOI: 10.1021/acs.analchem.3c02799] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
Electrospray ionization (ESI) is one of the main techniques used in mass spectrometry (MS) of nonvolatile compounds. ESI is a disordered process, in which a large number of polydisperse droplets are projected from a fluctuating Taylor cone and jet protruding ESI emitter. Here, we disclose a system for sectioning electrospray plumes to discrete packets with millisecond and submillisecond lifetime, which are introduced to the MS orifice, one at a time. A high-speed camera was triggered at 10,000 frames per second to capture consecutive images of the electrospray packets transmitted to the mass spectrometer. We further correlated the high-speed images of electrospray packets with MS signals of a test analyte (acetaminophen). Following computational treatment of the images, we determined the number of droplet observations (<300), average diameter of droplets (∼10-20 μm), and average volume of droplets (few tens of picoliters) in the individual electrospray packets. The result shows that most micrometer droplets (>10 μm) do not have any significant contribution to the MS signals. This finding is in agreement with the prior conjecture that most of the MS signals are mainly attributed to nanodroplets. Based on this finding, one can deduce that only a small number of the initial microdroplets effectively carry analyte molecules that undergo ionization. We discuss that, in future, one may propose a way to "recharge" the emitted initial micrometer droplets to increase the efficiency of conventional ESI setups.
Collapse
Affiliation(s)
- Chun-Yao Hsu
- Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Gurpur Rakesh D Prabhu
- Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Ching-Han Chang
- Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Pin-Chieh Hsu
- Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Krzysztof Buchowiecki
- Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| | - Pawel L Urban
- Department of Chemistry, National Tsing Hua University 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
- Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Rd., Hsinchu 300044, Taiwan
| |
Collapse
|
7
|
Geue N, Bennett TS, Ramakers LAI, Timco GA, McInnes EJL, Burton NA, Armentrout PB, Winpenny REP, Barran PE. Adduct Ions as Diagnostic Probes of Metallosupramolecular Complexes Using Ion Mobility Mass Spectrometry. Inorg Chem 2023; 62:2672-2679. [PMID: 36716284 PMCID: PMC9930111 DOI: 10.1021/acs.inorgchem.2c03698] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Following electrospray ionization, it is common for analytes to enter the gas phase accompanied by a charge-carrying ion, and in most cases, this addition is required to enable detection in the mass spectrometer. These small charge carriers may not be influential in solution but can markedly tune the analyte properties in the gas phase. Therefore, measuring their relative influence on the target molecule can assist our understanding of the structure and stability of the analyte. As the formed adducts are usually distinguishable by their mass, differences in the behavior of the analyte resulting from these added species (e.g., structure, stability, and conformational dynamics) can be easily extracted. Here, we use ion mobility mass spectrometry, supported by density functional theory, to investigate how charge carriers (H+, Na+, K+, and Cs+) as well as water influence the disassembly, stability, and conformational landscape of the homometallic ring [Cr8F8(O2CtBu)16] and the heterometallic rotaxanes [NH2RR'][Cr7MF8(O2CtBu)16], where M = MnII, FeII, CoII, NiII, CuII, ZnII, and CdII. The results yield new insights on their disassembly mechanisms and support previously reported trends in cavity size and transition metal properties, demonstrating the potential of adduct ion studies for characterizing metallosupramolecular complexes in general.
Collapse
Affiliation(s)
- Niklas Geue
- Michael
Barber Centre for Collaborative Mass Spectrometry, Manchester Institute
of Biotechnology, Department of Chemistry, The University of Manchester, 131 Princess Street, Manchester M1 7DN, UK
| | - Tom S. Bennett
- Department
of Chemistry, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
| | - Lennart A. I. Ramakers
- Michael
Barber Centre for Collaborative Mass Spectrometry, Manchester Institute
of Biotechnology, Department of Chemistry, The University of Manchester, 131 Princess Street, Manchester M1 7DN, UK
| | - Grigore A. Timco
- Department
of Chemistry, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
| | - Eric J. L. McInnes
- Department
of Chemistry, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
| | - Neil A. Burton
- Department
of Chemistry, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
| | - P. B. Armentrout
- Department
of Chemistry, University of Utah, Salt Lake City, Utah 84112, United States
| | - Richard E. P. Winpenny
- Department
of Chemistry, The University of Manchester, Oxford Road, Manchester M13 9PL, UK
| | - Perdita E. Barran
- Michael
Barber Centre for Collaborative Mass Spectrometry, Manchester Institute
of Biotechnology, Department of Chemistry, The University of Manchester, 131 Princess Street, Manchester M1 7DN, UK,
| |
Collapse
|
8
|
Lei W, Hu J, Chen HY, Xu JJ. Nanopore Liberates G-Quadruplexes from Biochemical Buffers for Accurate Mass Spectrometric Examination. Anal Chem 2022; 94:17972-17979. [PMID: 36515943 DOI: 10.1021/acs.analchem.2c04099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Achieving accurate measurements of G-quadruplexes (G4s), especially the characterization of their complicated non-covalent interactions with various components (such as metal ions and ligands) under physiological conditions, is of fundamental significance in unveiling their biological roles and developing antitumor drugs. By employing a nanopore ion emitter (∼30 nm), we demonstrated for the first time that G4 ions, which are free of non-specific adduction and meanwhile maintaining their pre-existing specific bindings with metal ions or ligands, can be directly liberated from common biochemical buffers (consisting of concentrated non-volatile salts of >150 mM) for mass spectrometric examination. Notably, the intermediate complexes of G4s with mixed di-cation coordination formed during the Na+/K+ exchange were successfully observed by mass spectrometry, whose structures were also revealed by the reconstructed circular dichroism spectra. We believe the nanopore-based ion emitters have built a solid bridge between native G4s in aqueous buffers and their accurate stoichiometries obtained by mass spectrometric examination.
Collapse
Affiliation(s)
- Wen Lei
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Jun Hu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Hong-Yuan Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| | - Jing-Juan Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| |
Collapse
|
9
|
Piovesana S, Capriotti AL, Cavaliere C, Cerrato A, Montone CM, Zenezini Chiozzi R, Laganà A. The Key Role of Metal Adducts in the Differentiation of Phosphopeptide from Sulfopeptide Sequences by High-Resolution Mass Spectrometry. Anal Chem 2022; 94:9234-9241. [PMID: 35714062 PMCID: PMC9260711 DOI: 10.1021/acs.analchem.1c05621] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 06/06/2022] [Indexed: 11/28/2022]
Abstract
Site localization of protein sulfation by high-throughput proteomics remains challenging despite the technological improvements. In this study, sequence analysis and site localization of sulfation in tryptic peptides were determined under a conventional nano-liquid chromatography-mass spectrometry configuration. Tryptic sulfopeptide standards were used to study different fragmentation strategies, including collision-induced dissociation (CID), higher-energy collisional dissociation (HCD), electron-transfer dissociation (ETD), electron-transfer/higher-energy collision dissociation (EThcD), and electron-transfer/collision-induced dissociation (ETciD), in the positive ionization mode. Sulfopeptides displayed only neutral loss of SO3 under CID, while the sequence could be determined for all other tested fragmentation techniques. Results were compared to the same sequences with phosphotyrosine, indicating important differences, as the sequence and modification localization could be studied by all fragmentation strategies. However, the use of metal adducts, especially potassium, provided valuable information for sulfopeptide localization in ETD and ETD-hybrid strategies by stabilizing the modification and increasing the charge state of sulfopeptides. In these conditions, both the sequence and localization could be obtained. In-source neutral loss of SO3 under EThcD provided diagnostic peaks suitable to distinguish the sulfopeptides from the nearly isobaric phosphopeptides. Further confirmation on the modification type was found in the negative ionization mode, where phosphopeptides always had the typical phosphate product ion corresponding to PO3-.
Collapse
Affiliation(s)
- Susy Piovesana
- Department
of Chemistry, University of Rome “La
Sapienza”, Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Anna Laura Capriotti
- Department
of Chemistry, University of Rome “La
Sapienza”, Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Chiara Cavaliere
- Department
of Chemistry, University of Rome “La
Sapienza”, Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Andrea Cerrato
- Department
of Chemistry, University of Rome “La
Sapienza”, Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Carmela Maria Montone
- Department
of Chemistry, University of Rome “La
Sapienza”, Piazzale Aldo Moro 5, Rome 00185, Italy
| | - Riccardo Zenezini Chiozzi
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Padualaan 8, Utrecht 3584 CH, The Netherlands
- Netherlands
Proteomics Centre, Padualaan
8, Utrecht 3584 CH, The Netherlands
| | - Aldo Laganà
- Department
of Chemistry, University of Rome “La
Sapienza”, Piazzale Aldo Moro 5, Rome 00185, Italy
| |
Collapse
|
10
|
Lei W, Hu J, Chen HY, Xu JJ. Combined strategies for suppressing nonspecific cationic adduction to G-quadruplexes in electrospray ionization mass spectrometry. Anal Chim Acta 2022; 1220:340146. [DOI: 10.1016/j.aca.2022.340146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 06/21/2022] [Accepted: 07/03/2022] [Indexed: 11/01/2022]
|
11
|
Liu R, Xia S, Li H. Native top-down mass spectrometry for higher-order structural characterization of proteins and complexes. MASS SPECTROMETRY REVIEWS 2022:e21793. [PMID: 35757976 DOI: 10.1002/mas.21793] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 05/23/2022] [Accepted: 05/24/2022] [Indexed: 06/15/2023]
Abstract
Progress in structural biology research has led to a high demand for powerful and yet complementary analytical tools for structural characterization of proteins and protein complexes. This demand has significantly increased interest in native mass spectrometry (nMS), particularly native top-down mass spectrometry (nTDMS) in the past decade. This review highlights recent advances in nTDMS for structural research of biological assemblies, with a particular focus on the extra multi-layers of information enabled by TDMS. We include a short introduction of sample preparation and ionization to nMS, tandem fragmentation techniques as well as mass analyzers and software/analysis pipelines used for nTDMS. We highlight unique structural information offered by nTDMS and examples of its broad range of applications in proteins, protein-ligand interactions (metal, cofactor/drug, DNA/RNA, and protein), therapeutic antibodies and antigen-antibody complexes, membrane proteins, macromolecular machineries (ribosome, nucleosome, proteosome, and viruses), to endogenous protein complexes. The challenges, potential, along with perspectives of nTDMS methods for the analysis of proteins and protein assemblies in recombinant and biological samples are discussed.
Collapse
Affiliation(s)
- Ruijie Liu
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, China
| | - Shujun Xia
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, China
| | - Huilin Li
- School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, China
- Guangdong Key Laboratory of Chiral Molecule and Drug Discovery, School of Pharmaceutical Sciences, Sun Yat-sen University, Guangzhou, China
| |
Collapse
|
12
|
Walz A, Stoiber K, Huettig A, Schlichting H, Barth JV. Navigate Flying Molecular Elephants Safely to the Ground: Mass-Selective Soft Landing up to the Mega-Dalton Range by Electrospray Controlled Ion-Beam Deposition. Anal Chem 2022; 94:7767-7778. [PMID: 35609119 PMCID: PMC9178560 DOI: 10.1021/acs.analchem.1c04495] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The prototype of a highly versatile and efficient preparative mass spectrometry system used for the deposition of molecules in ultrahigh vacuum (UHV) is presented, along with encouraging performance data obtained using four model species that are thermolabile or not sublimable. The test panel comprises two small organic compounds, a small and very large protein, and a large DNA species covering a 4-log mass range up to 1.7 MDa as part of a broad spectrum of analyte species evaluated to date. Three designs of innovative ion guides, a novel digital mass-selective quadrupole (dQMF), and a standard electrospray ionization (ESI) source are combined to an integrated device, abbreviated electrospray controlled ion-beam deposition (ES-CIBD). Full control is achieved by (i) the square-wave-driven radiofrequency (RF) ion guides with steadily tunable frequencies, including a dQMF allowing for investigation, purification, and deposition of a virtually unlimited m/z range, (ii) the adjustable landing energy of ions down to ∼2 eV/z enabling integrity-preserving soft landing, (iii) the deposition in UHV with high ion beam intensity (up to 3 nA) limiting contaminations and deposition time, and (iv) direct coverage control via the deposited charge. The maximum resolution of R = 650 and overall efficiency up to Ttotal = 4.4% calculated from the solution to UHV deposition are advantageous, whereby the latter can be further enhanced by optimizing ionization performance. In the setup presented, a scanning tunneling microscope (STM) is attached for in situ UHV investigations of deposited species, demonstrating a selective, structure-preserving process and atomically clean layers.
Collapse
Affiliation(s)
- Andreas Walz
- Physics Department E20, Technical University of Munich, 85748 Garching, Germany
| | - Karolina Stoiber
- Physics Department E20, Technical University of Munich, 85748 Garching, Germany
| | - Annette Huettig
- Physics Department E20, Technical University of Munich, 85748 Garching, Germany
| | - Hartmut Schlichting
- Physics Department E20, Technical University of Munich, 85748 Garching, Germany
| | - Johannes V Barth
- Physics Department E20, Technical University of Munich, 85748 Garching, Germany
| |
Collapse
|
13
|
Abstract
Native mass spectrometry (nMS) has emerged as an important tool in studying the structure and function of macromolecules and their complexes in the gas phase. In this review, we cover recent advances in nMS and related techniques including sample preparation, instrumentation, activation methods, and data analysis software. These advances have enabled nMS-based techniques to address a variety of challenging questions in structural biology. The second half of this review highlights recent applications of these technologies and surveys the classes of complexes that can be studied with nMS. Complementarity of nMS to existing structural biology techniques and current challenges in nMS are also addressed.
Collapse
Affiliation(s)
- Kelly R Karch
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, USA;
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, Ohio, USA
| | - Dalton T Snyder
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, Ohio, USA
| | - Sophie R Harvey
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, USA;
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, Ohio, USA
| | - Vicki H Wysocki
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, USA;
- Resource for Native Mass Spectrometry Guided Structural Biology, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
14
|
Zhao W, Xu J. Chemical Measurement and Analysis: from Phenomenon to Essence. CHINESE J CHEM 2022. [DOI: 10.1002/cjoc.202200134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Wei Zhao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering Nanjing University Nanjing 210023 China
- Institute of Nanochemistry and Nanobiology, School of Environmental and Chemical Engineering Shanghai University Shanghai 200444 China
| | - Jing‐Juan Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering Nanjing University Nanjing 210023 China
| |
Collapse
|
15
|
|
16
|
Abstract
Native mass spectrometry (MS) involves the analysis and characterization of macromolecules, predominantly intact proteins and protein complexes, whereby as much as possible the native structural features of the analytes are retained. As such, native MS enables the study of secondary, tertiary, and even quaternary structure of proteins and other biomolecules. Native MS represents a relatively recent addition to the analytical toolbox of mass spectrometry and has over the past decade experienced immense growth, especially in enhancing sensitivity and resolving power but also in ease of use. With the advent of dedicated mass analyzers, sample preparation and separation approaches, targeted fragmentation techniques, and software solutions, the number of practitioners and novel applications has risen in both academia and industry. This review focuses on recent developments, particularly in high-resolution native MS, describing applications in the structural analysis of protein assemblies, proteoform profiling of─among others─biopharmaceuticals and plasma proteins, and quantitative and qualitative analysis of protein-ligand interactions, with the latter covering lipid, drug, and carbohydrate molecules, to name a few.
Collapse
Affiliation(s)
- Sem Tamara
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, University of Utrecht, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Maurits A. den Boer
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, University of Utrecht, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| | - Albert J. R. Heck
- Biomolecular
Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular
Research and Utrecht Institute for Pharmaceutical Sciences, University of Utrecht, Padualaan 8, 3584
CH Utrecht, The Netherlands
- Netherlands
Proteomics Center, Padualaan
8, 3584 CH Utrecht, The Netherlands
| |
Collapse
|
17
|
Jordan JS, Xia Z, Williams ER. Tips on Making Tiny Tips: Secrets to Submicron Nanoelectrospray Emitters. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:607-611. [PMID: 35157433 DOI: 10.1021/jasms.1c00372] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Nanoelectrospray ionization emitters with submicron tip diameters have significant advantages for use in native mass spectrometry, including the ability to produce resolved charge-state distributions for proteins and macromolecular complexes from standard biochemical buffers that contain high concentrations of nonvolatile salts and to prevent nonspecific aggregation that can occur during droplet evaporation. We report on various factors affecting the tip morphology and provide suggestions for producing and using emitters with submicron tips. Effects of pulling parameters for a Sutter Instrument P-87 tip puller on the resulting tip diameter and morphology are shown. The "Pull" parameter has the largest effect on tip diameter, followed by "Velocity", "Pressure", and "Heat", whereas the "Time" parameter has minimal effect beyond a lower threshold. High "Pull" values generate emitters with multiple tapers, whereas high "Velocity" values generate a tip with only a single tapered region. A protocol for producing reproducible emitters in the submicron size range, as well as guidelines and tips for using these emitters with standard biochemical buffers that contain high concentrations of nonvolatile salts, is presented with the aim of expanding their use within the native mass spectrometry community.
Collapse
Affiliation(s)
- Jacob S Jordan
- Department of Chemistry, University of California, Berkeley, California 94720, United States
| | - Zijie Xia
- Department of Chemistry, University of California, Berkeley, California 94720, United States
| | - Evan R Williams
- Department of Chemistry, University of California, Berkeley, California 94720, United States
| |
Collapse
|
18
|
Yin Z, Du M, Chen D, Zhang W, Huang W, Wu X, Yan S. Rapid structural discrimination of IgG antibodies by multicharge-state collision-induced unfolding. RSC Adv 2021; 11:36502-36510. [PMID: 35494361 PMCID: PMC9043582 DOI: 10.1039/d1ra06486j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Accepted: 11/06/2021] [Indexed: 11/29/2022] Open
Abstract
Immunoglobulin G (IgG) antibodies are an important class of biotherapeutics that target various diseases, such as cancers, neurodegenerative disorders, and autoimmune diseases, yet rapid discrimination of IgG antibodies remains a great challenge due to heterogeneity, flexibility, and large size. Herein, we demonstrate a simplified multicharge-state collision-induced unfolding (CIU) method for rapid differentiation of four IgG isotypes that differ in terms of the numbers and patterns of disulfide bonds, bypassing tedious single charge-state selection in advance. The results presented herein reveal that gas-phase unfolding behaviors have a strong dependence on charge states outside IgG surfaces; therefore, multicharge-state CIU analysis of IgG subtypes could offer a great opportunity to gain deeper insights into their gas-phase structural differentiation. The full discrimination of IgG antibody isoforms that possess different disulfide bond numbers and even subtle disulfide bonding patterns can be achieved based on their charge-dependent gas-phase unfolding behaviors and root-mean square deviation in CIU difference spectra. Taken together, the incorporation of all charge states observed in a native ion mobility-mass spectrometry (IM-MS) experiment to CIU analysis could make this strategy sensitive to more subtle structural discrepancies, facilitating the rapid discrimination and evaluation of innovative structurally similar biotherapeutic candidates with unexplored functions.
Collapse
Affiliation(s)
- Zhibin Yin
- Guangdong Key Laboratory for Crop Germplasm Resources Preservation and Utilization, Agro-biological Gene Research Center, Guangdong Academy of Agricultural Sciences Guangzhou 510640 China
| | - Mingyi Du
- Guangdong Key Laboratory for Crop Germplasm Resources Preservation and Utilization, Agro-biological Gene Research Center, Guangdong Academy of Agricultural Sciences Guangzhou 510640 China
- State Key Laboratory for Conservation and Utilization of Subtropical Agro-bioresources, Key Laboratory of Natural Pesticide and Chemical Biology of the Ministry of Education, South China Agricultural University Guangzhou 510642 China
| | - Dong Chen
- Guangdong Key Laboratory for Crop Germplasm Resources Preservation and Utilization, Agro-biological Gene Research Center, Guangdong Academy of Agricultural Sciences Guangzhou 510640 China
- State Key Laboratory for Conservation and Utilization of Subtropical Agro-bioresources, Key Laboratory of Natural Pesticide and Chemical Biology of the Ministry of Education, South China Agricultural University Guangzhou 510642 China
| | - Wenyang Zhang
- Guangdong Key Laboratory for Crop Germplasm Resources Preservation and Utilization, Agro-biological Gene Research Center, Guangdong Academy of Agricultural Sciences Guangzhou 510640 China
| | - Wenjie Huang
- Guangdong Key Laboratory for Crop Germplasm Resources Preservation and Utilization, Agro-biological Gene Research Center, Guangdong Academy of Agricultural Sciences Guangzhou 510640 China
| | - Xinzhou Wu
- State Key Laboratory for Conservation and Utilization of Subtropical Agro-bioresources, Key Laboratory of Natural Pesticide and Chemical Biology of the Ministry of Education, South China Agricultural University Guangzhou 510642 China
| | - Shijuan Yan
- Guangdong Key Laboratory for Crop Germplasm Resources Preservation and Utilization, Agro-biological Gene Research Center, Guangdong Academy of Agricultural Sciences Guangzhou 510640 China
| |
Collapse
|
19
|
Aliyari E, Konermann L. Atomistic Insights into the Formation of Nonspecific Protein Complexes during Electrospray Ionization. Anal Chem 2021; 93:12748-12757. [PMID: 34494821 DOI: 10.1021/acs.analchem.1c02836] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Native electrospray ionization (ESI)-mass spectrometry (MS) is widely used for the detection and characterization of multi-protein complexes. A well-known problem with this approach is the possible occurrence of nonspecific protein clustering in the ESI plume. This effect can distort the results of binding affinity measurements, and it can even generate gas-phase complexes from proteins that are strictly monomeric in bulk solution. By combining experiments and molecular dynamics (MD) simulations, the current work for the first time provides detailed insights into the ESI clustering of proteins. Using ubiquitin as a model system, we demonstrate how the entrapment of more than one protein molecule in an ESI droplet can generate nonspecific clusters (e.g., dimers or trimers) via solvent evaporation to dryness. These events are in line with earlier proposals, according to which protein clustering is associated with the charged residue model (CRM). MD simulations on cytochrome c (which carries a large intrinsic positive charge) confirmed the viability of this CRM avenue. In addition, the cytochrome c data uncovered an alternative mechanism where protein-protein contacts were formed early within ESI droplets, followed by cluster ejection from the droplet surface. This second pathway is consistent with the ion evaporation model (IEM). The observation of these IEM events for large protein clusters is unexpected because the IEM has been thought to be associated primarily with low-molecular-weight analytes. In all cases, our MD simulations produced protein clusters that were stabilized by intermolecular salt bridges. The MD-generated charge states agreed with experiments. Overall, this work reveals that ESI-induced protein clustering does not follow a tightly orchestrated pathway but can proceed along different avenues.
Collapse
Affiliation(s)
- Elnaz Aliyari
- Department of Chemistry, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| | - Lars Konermann
- Department of Chemistry, The University of Western Ontario, London, Ontario N6A 5B7, Canada
| |
Collapse
|
20
|
Nitsche T, Sheil MM, Blinco JP, Barner-Kowollik C, Blanksby SJ. Electrospray Ionization-Mass Spectrometry of Synthetic Polymers Functionalized with Carboxylic Acid End-Groups. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2123-2134. [PMID: 34242006 DOI: 10.1021/jasms.1c00085] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Electrospray ionization-mass spectrometry (ESI-MS) of low-charging synthetic polymers typically produces mass spectra exhibiting a bias toward the low-mass region of the polymer mass distribution. To examine the origin(s) of this ionization bias, narrow dispersity polystyrene polymers (Đ < 1.10) were prepared with ionizable carboxylic acid end-groups at one or both chain termini. The mixture complexity was further reduced through preparative size-exclusion chromatography (SEC), and these well-defined polymers were subjected to negative ion ESI-MS on a high-resolution instrument with a mass-to-charge (m/z) range up to 8000. Incorporation of one carboxylic acid end-group facilitated the generation of singly charged [M - H]- ions across the entire range of the mass analyzer. The comparison of mass spectra with size-exclusion chromatograms of the same polymer revealed an ionization bias toward lower masses, which was partially overcome through fractionation, modification of electrospray solvent, and increased declustering potentials. Incorporation of a second ionizable moiety within polymers of equivalent size facilitated multiply charged [M - 2H]2- ion formation with significantly improved ionization efficiency, spectral coverage of the molar mass distribution, and minimal cluster ion formation. These findings indicate that increased charging of polymers through multiple, well-defined sites of ionization can enhance volatilization and ionization of higher-mass polymers. Generation of higher-molecular-weight polymers in low-charge states-while possible under ideal conditions-competes ineffectively with either nonspecific, multiple-charging of similar sized polymers or ionization of the smaller polymers in the distribution.
Collapse
Affiliation(s)
- Tobias Nitsche
- School of Chemistry and Physics, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
- Centre for Materials Science, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| | - Margaret M Sheil
- School of Chemistry and Physics, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| | - James P Blinco
- School of Chemistry and Physics, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
- Centre for Materials Science, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| | - Christopher Barner-Kowollik
- School of Chemistry and Physics, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
- Centre for Materials Science, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| | - Stephen J Blanksby
- Centre for Materials Science, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
- Central Analytical Research Facility, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000, Australia
| |
Collapse
|
21
|
Agasid MT, Sørensen L, Urner LH, Yan J, Robinson CV. The Effects of Sodium Ions on Ligand Binding and Conformational States of G Protein-Coupled Receptors-Insights from Mass Spectrometry. J Am Chem Soc 2021; 143:4085-4089. [PMID: 33711230 PMCID: PMC7995251 DOI: 10.1021/jacs.0c11837] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
![]()
The use of mass spectrometry
to investigate proteins is now well
established and provides invaluable information for both soluble and
membrane protein assemblies. Maintaining transient noncovalent interactions
under physiological conditions, however, remains challenging. Here,
using nanoscale electrospray ionization emitters, we establish conditions
that enable mass spectrometry of two G protein-coupled receptors (GPCR)
from buffers containing high concentrations of sodium ions. For the
Class A GPCR, the adenosine 2A receptor, we observe ligand-induced
changes to sodium binding of the receptor at the level of individual
sodium ions. We find that antagonists promote sodium binding while
agonists attenuate sodium binding. These findings are in line with
high-resolution X-ray crystallography wherein only inactive conformations
retain sodium ions in allosteric binding pockets. For the glucagon
receptor (a Class B GPCR) we observed enhanced ligand binding in electrospray
buffers containing high concentrations of sodium, as opposed to ammonium
acetate buffers. A combination of native and -omics mass spectrometry
revealed the presence of a lipophilic negative allosteric modulator.
These experiments highlight the advantages of implementing native
mass spectrometry, from electrospray buffers containing high concentrations
of physiologically relevant salts, to inform on allosteric ions or
ligands with the potential to define their roles on GPCR function.
Collapse
Affiliation(s)
- Mark T Agasid
- Department of Chemistry, University of Oxford, 12 Mansfield Road, Oxford OX1 3TA, U.K
| | - Lars Sørensen
- Global Research Technologies, Novo Nordisk A/S, Novo Nordisk Park, Måløv 2760, Denmark
| | - Leonhard H Urner
- Department of Chemistry, University of Oxford, 12 Mansfield Road, Oxford OX1 3TA, U.K
| | - Jun Yan
- Global Research Technologies, Novo Nordisk A/S, Novo Nordisk Park, Måløv 2760, Denmark
| | - Carol V Robinson
- Department of Chemistry, University of Oxford, 12 Mansfield Road, Oxford OX1 3TA, U.K
| |
Collapse
|
22
|
Chen Y, Yuan S, Liu Y, Huang G. Rapid desalting during electrospray ionization mass spectrometry for investigating protein-ligand interactions in the presence of concentrated salts. Anal Chim Acta 2021; 1141:120-126. [PMID: 33248644 DOI: 10.1016/j.aca.2020.10.036] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 10/10/2020] [Accepted: 10/19/2020] [Indexed: 11/18/2022]
Abstract
Investigation of protein-ligand interactions in physiological conditions is crucial for better understanding of biochemistry because the binding stoichiometry and conformations of complexes in biological processes, such as various types of regulation and transportation, could reveal key pathways in organisms. Nanoelectrospray ionization mass spectrometry is widely used in studies of biological processes and systems biology. However, non-volatile salts in biological fluid may adversely interfere with nanoelectrospray ionization mass spectrometry. In this study, the previously developed method of induced nanoelectrospray ionization was used to facilitate in situ desalting of protein in solutions with high concentrations of non-volatile salts, and direct investigation of protein-ligand interactions for the first time. In situ desalting occurred at the tip of emitters within a short period lasting for a few to tens of milliseconds, enabling the maintenance of nativelike conditions compatible with mass spectrometry measurements. Induced nanoelectrospray ionization was driven by pulsed potential and exhibited microelectrophoresis effect in each spray cycle, which is not observed in conventional nanoelectrospray ionization because the continuous spray procedure is driven by direct current. Microelectrophoresis caused desalting through micron-sized spray emitters (1-20 μm), as confirmed experimentally with proteins in 100 mM NaCl solution. The method developed in this study has been further illustrated as a potential option for fast and direct identification of protein-ligand (small molecules or metal ions) interactions in complex samples. The results of this study demonstrate that the newly developed method may represent a reliable approach for investigations of proteins and protein complexes in biological samples.
Collapse
Affiliation(s)
- Yuting Chen
- Hefei National Laboratory for Physical Sciences at the Microscale, School of Chemistry and Materials Science, University of Science and Technology of China, 230026, Hefei, China
| | - Siming Yuan
- Hefei National Laboratory for Physical Sciences at the Microscale, School of Chemistry and Materials Science, University of Science and Technology of China, 230026, Hefei, China
| | - Yangzhong Liu
- Hefei National Laboratory for Physical Sciences at the Microscale, School of Chemistry and Materials Science, University of Science and Technology of China, 230026, Hefei, China
| | - Guangming Huang
- Hefei National Laboratory for Physical Sciences at the Microscale, School of Chemistry and Materials Science, University of Science and Technology of China, 230026, Hefei, China; National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui, 230029, PR China.
| |
Collapse
|
23
|
Xu S, Xue J, Bai Y, Liu H. High-Throughput Single-Cell Immunoassay in the Cellular Native Environment Using Online Desalting Dual-Spray Mass Spectrometry. Anal Chem 2020; 92:15854-15861. [DOI: 10.1021/acs.analchem.0c03167] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Shuting Xu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Jinjuan Xue
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Yu Bai
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| | - Huwei Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, P. R. China
| |
Collapse
|
24
|
Alexpandi R, Gopi CVVM, Durgadevi R, Kim HJ, Pandian SK, Ravi AV. Metal sensing-carbon dots loaded TiO 2-nanocomposite for photocatalytic bacterial deactivation and application in aquaculture. Sci Rep 2020; 10:12883. [PMID: 32733064 PMCID: PMC7393085 DOI: 10.1038/s41598-020-69888-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 06/23/2020] [Indexed: 11/08/2022] Open
Abstract
Nowadays, bioactive nanomaterials have been attracted the researcher's enthusiasm in various fields. Herein, Diplocyclos palmatus leaf extract-derived green-fluorescence carbon dots (DP-CDs) were prepared using the hydrothermal method. Due to the strong fluorescence stability, the prepared DP-CDs were coated on filter-paper to make a fluorometric sensor-strip for Fe3+ detection. After, a bandgap-narrowed DP-CDs/TiO2 nanocomposite (DCTN) was prepared using the methanolic extract of D. palmatus. The prepared DCTN exhibited improved photocatalytic bacterial deactivation under sunlight irradiation. The DCTN-photocatalysis slaughtered V. harveyi cells by the production of reactive oxygen species, which prompting oxidative stress, damaging the cell membrane and cellular constituents. These results suggest the plausible mode of bactericidal action of DCTN-photocatalysis under sunlight. Further, the DCTN has shown potent anti-biofilm activity against V. harveyi, and thereby, DCTN extended the survival of V. harveyi-infected shrimps during the in vivo trial with Litopenaeus vannamei. Notably, this is the first report for the disinfection of V. harveyi-mediated acute-hepatopancreatic necrosis disease (AHPND) using nanocomposite. The reduced internal-colonization of V. harveyi on the hepatopancreas as well as the rescue action of the pathognomonic effect in the experimental animals demonstrated the anti-infection potential of DCTN against V. harveyi-mediated AHPND in aquaculture.
Collapse
Affiliation(s)
- Rajaiah Alexpandi
- Lab in Microbiology and Marine Biotechnology, Department of Biotechnology, School of Biological Sciences, Alagappa University, Karaikudi, 630 003, India
| | - Chandu V V Muralee Gopi
- Lab in Laser and Sensor Application, School of Electrical and Computer Engineering, Pusan National University, Busandaehak-ro 63 beon-gil, Geumjeong-gu, Busan, 46241, South Korea
| | - Ravindran Durgadevi
- Lab in Microbiology and Marine Biotechnology, Department of Biotechnology, School of Biological Sciences, Alagappa University, Karaikudi, 630 003, India
| | - Hee-Je Kim
- Lab in Laser and Sensor Application, School of Electrical and Computer Engineering, Pusan National University, Busandaehak-ro 63 beon-gil, Geumjeong-gu, Busan, 46241, South Korea
| | - Shunmugiah Karutha Pandian
- Lab in Microbiology and Marine Biotechnology, Department of Biotechnology, School of Biological Sciences, Alagappa University, Karaikudi, 630 003, India
| | - Arumugam Veera Ravi
- Lab in Microbiology and Marine Biotechnology, Department of Biotechnology, School of Biological Sciences, Alagappa University, Karaikudi, 630 003, India.
| |
Collapse
|
25
|
Nguyen GTH, Nocentini A, Angeli A, Gratteri P, Supuran CT, Donald WA. Perfluoroalkyl Substances of Significant Environmental Concern Can Strongly Inhibit Human Carbonic Anhydrase Isozymes. Anal Chem 2020; 92:4614-4622. [PMID: 32096628 DOI: 10.1021/acs.analchem.0c00163] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Perfluoroalkyl substances (PFASs) persist and are ubiquitous in the environment. The origins of PFAS toxicity and how they specifically affect the functions of proteins remain unclear. Herein, we report that PFASs can strongly inhibit the activity of human carbonic anhydrases (hCAs), which are ubiquitous enzymes that catalyze the hydration of CO2, are abundant in the blood and organs of mammals, and involved in pH regulation, ion homeostasis, and biosynthesis. The interactions between PFASs and hCAs were investigated using stopped-flow kinetic enzyme-inhibition measurements, native mass spectrometry (MS), and ligand-docking simulations. Narrow-bore emitters in native MS with inner diameters of ∼300 nm were used to directly and simultaneously measure the dissociation constants of 11 PFASs to an enzyme, which was not possible using conventional emitters. The data from native MS and stopped-flow measurements were in excellent agreement. Of 15 PFASs investigated, eight can inhibit at least one of four hCA isozymes (I, II, IX, and XII) with submicromolar inhibition constants, including perfluorooctanoic acid, perfluorooctanesulfonamide, and perfluorooctanesulfonic acid. Some PFASs, including those with both short and long perfluoromethylene chains, can effectively inhibit at least one hCA isozyme with low nanomolar inhibition constants.
Collapse
Affiliation(s)
- Giang T H Nguyen
- School of Chemistry, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Alessio Nocentini
- Department NEUROFARBA-Pharmaceutical and Nutraceutical Section, University of Firenze, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Firenze, Italy.,Department NEUROFARBA-Pharmaceutical and Nutraceutical Section, Laboratory of Molecular Modeling Cheminformatics & QSAR, University of Firenze, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Firenze, Italy
| | - Andrea Angeli
- Department NEUROFARBA-Pharmaceutical and Nutraceutical Section, University of Firenze, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Firenze, Italy
| | - Paola Gratteri
- Department NEUROFARBA-Pharmaceutical and Nutraceutical Section, Laboratory of Molecular Modeling Cheminformatics & QSAR, University of Firenze, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Firenze, Italy
| | - Claudiu T Supuran
- Department NEUROFARBA-Pharmaceutical and Nutraceutical Section, University of Firenze, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Firenze, Italy
| | - William A Donald
- School of Chemistry, University of New South Wales, Sydney, New South Wales 2052, Australia
| |
Collapse
|
26
|
Demeiry ME, Ali A, Abouleila Y, Shimizu Y, Masujima T, Salam RA, Hadad G, Emara S. Quantification and targeted detection of ciprofloxacin in dosage form and human urine by direct injection nano-electrospray ionization multi-stage mass spectrometry. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104534] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
27
|
Lermyte F, Everett J, Lam YPY, Wootton CA, Brooks J, Barrow MP, Telling ND, Sadler PJ, O'Connor PB, Collingwood JF. Metal Ion Binding to the Amyloid β Monomer Studied by Native Top-Down FTICR Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2123-2134. [PMID: 31350722 PMCID: PMC6805827 DOI: 10.1007/s13361-019-02283-7] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 07/01/2019] [Accepted: 07/01/2019] [Indexed: 05/22/2023]
Abstract
Native top-down mass spectrometry is a fast, robust biophysical technique that can provide molecular-scale information on the interaction between proteins or peptides and ligands, including metal cations. Here we have analyzed complexes of the full-length amyloid β (1-42) monomer with a range of (patho)physiologically relevant metal cations using native Fourier transform ion cyclotron resonance mass spectrometry and three different fragmentation methods-collision-induced dissociation, electron capture dissociation, and infrared multiphoton dissociation-all yielding consistent results. Amyloid β is of particular interest as its oligomerization and aggregation are major events in the etiology of Alzheimer's disease, and it is known that interactions between the peptide and bioavailable metal cations have the potential to significantly damage neurons. Those metals which exhibited the strongest binding to the peptide (Cu2+, Co2+, Ni2+) all shared a very similar binding region containing two of the histidine residues near the N-terminus (His6, His13). Notably, Fe3+ bound to the peptide only when stabilized toward hydrolysis, aggregation, and precipitation by a chelating ligand, binding in the region between Ser8 and Gly25. We also identified two additional binding regions near the flexible, hydrophobic C-terminus, where other metals (Mg2+, Ca2+, Mn2+, Na+, and K+) bound more weakly-one centered on Leu34, and one on Gly38. Unexpectedly, collisional activation of the complex formed between the peptide and [CoIII(NH3)6]3+ induced gas-phase reduction of the metal to CoII, allowing the peptide to fragment via radical-based dissociation pathways. This work demonstrates how native mass spectrometry can provide new insights into the interactions between amyloid β and metal cations.
Collapse
Affiliation(s)
- Frederik Lermyte
- School of Engineering, University of Warwick, Coventry, CV4 7AL, UK.
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK.
| | - James Everett
- School of Engineering, University of Warwick, Coventry, CV4 7AL, UK
- Institute for Science and Technology in Medicine, Keele University, Stoke-on-Trent, Staffordshire, ST4 7QB, UK
| | - Yuko P Y Lam
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK
| | | | - Jake Brooks
- School of Engineering, University of Warwick, Coventry, CV4 7AL, UK
| | - Mark P Barrow
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK
| | - Neil D Telling
- Institute for Science and Technology in Medicine, Keele University, Stoke-on-Trent, Staffordshire, ST4 7QB, UK
| | - Peter J Sadler
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK
| | | |
Collapse
|
28
|
Hu J, Lei W, Wang J, Chen HY, Xu JJ. Preservation of Protein Zwitterionic States in the Transition from Solution to Gas Phase Revealed by Sodium Adduction Mass Spectrometry. Anal Chem 2019; 91:7858-7863. [PMID: 31134800 DOI: 10.1021/acs.analchem.9b01602] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The structural characterization of proteins and their interaction network mapping in the gas phase highlights the need to preserve their most nativelike conformers in the transition from the solution to gas phase. Zwitterionic interactions in a protein are weak bonds between oppositely charged residues, which make an important contribution to protein stability. However, it is still not clear whether the native zwitterionic states of proteins can be retained or not when it is transferred from the solution to gas phase. Using the nonspecific Na+ adduction as a novel signature, here we show that the zwitterionic states of proteins can be preserved when a moderated droplet desolvation condition (temperature <30 °C) is used in native electrospray ionization mass spectrometry. The very low-level nonspecific metal adduction to proteins under such conditions also enables rapid and direct determination of the binding states of metal-binding proteins and sensitive detection of proteins from solutions containing highly concentrated involatile salts (e.g., 50 mM NaCl). We believe that our findings can be instructive for performing mass spectrometric analysis of proteins and useful for protein ions desalting which simply involves altering the temperature and flow rate of drying gas in the desolvation region.
Collapse
Affiliation(s)
- Jun Hu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Wen Lei
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Jiang Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Hong-Yuan Chen
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| | - Jing-Juan Xu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering , Nanjing University , Nanjing 210023 , P. R. China
| |
Collapse
|
29
|
Yu R, Ying Y, Gao R, Long Y. Confined Nanopipette Sensing: From Single Molecules, Single Nanoparticles, to Single Cells. Angew Chem Int Ed Engl 2019; 58:3706-3714. [DOI: 10.1002/anie.201803229] [Citation(s) in RCA: 129] [Impact Index Per Article: 21.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 05/25/2018] [Indexed: 01/09/2023]
Affiliation(s)
- Ru‐Jia Yu
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 P. R. China
| | - Yi‐Lun Ying
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 P. R. China
| | - Rui Gao
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 P. R. China
| | - Yi‐Tao Long
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 P. R. China
| |
Collapse
|
30
|
Nguyen GH, Tran TN, Podgorski MN, Bell SG, Supuran CT, Donald WA. Nanoscale Ion Emitters in Native Mass Spectrometry for Measuring Ligand-Protein Binding Affinities. ACS CENTRAL SCIENCE 2019; 5:308-318. [PMID: 30834319 PMCID: PMC6396573 DOI: 10.1021/acscentsci.8b00787] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Indexed: 05/20/2023]
Abstract
Electrospray ionization (ESI) mass spectrometry (MS) is a crucial method for rapidly determining the interactions between small molecules and proteins with ultrahigh sensitivity. However, nonvolatile molecules and salts that are often necessary to stabilize the native structures of protein-ligand complexes can readily adduct to protein ions, broaden spectral peaks, and lower signal-to-noise ratios in native MS. ESI emitters with narrow tip diameters (∼250 nm) were used to significantly reduce the extent of adduction of salt and nonvolatile molecules to protein complexes to more accurately measure ligand-protein binding constants than by use of conventional larger-bore emitters under these conditions. As a result of decreased salt adduction, peaks corresponding to protein-ligand complexes that differ in relative molecular weight by as low as 0.06% can be readily resolved. For low-molecular-weight anion ligands formed from sodium salts, anion-bound and unbound protein ions that differ in relative mass by 0.2% were completely baseline resolved using nanoscale emitters, which was not possible under these conditions using conventional emitters. Owing to the improved spectral resolution obtained using narrow-bore emitters and an analytically derived equation, K d values were simultaneously obtained for at least six ligands to a single druggable protein target from one spectrum for the first time. This research suggests that ligand-protein binding constants can be directly and accurately measured from solutions with high concentrations of nonvolatile buffers and salts by native MS.
Collapse
Affiliation(s)
- Giang
T. H. Nguyen
- School
of Chemistry, University of New South Wales, Dalton Building, Sydney, New South Wales 2052, Australia
| | - Thinh N. Tran
- School
of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Matthew N. Podgorski
- Department
of Chemistry, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Stephen G. Bell
- Department
of Chemistry, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Claudiu T. Supuran
- Department
of Neuroscience, Psychology, Drug Research and Child’s Health,
Section of Pharmaceutical and Nutraceutical Sciences, University of Florence, Via Ugo Schiff 6, 50019 Sesto Fiorentino, Italy
| | - William A. Donald
- School
of Chemistry, University of New South Wales, Dalton Building, Sydney, New South Wales 2052, Australia
- Phone: +61 (2) 9385 8827. E-mail:
| |
Collapse
|
31
|
Baker LA, Jagdale GS. On the intersection of electrochemistry and mass spectrometry. CURRENT OPINION IN ELECTROCHEMISTRY 2019; 13:140-146. [PMID: 33981910 PMCID: PMC8112614 DOI: 10.1016/j.coelec.2018.12.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The application of nanopipettes, developed first as a tool for electrochemistry and electrophysiology, as tools for mass spectrometry is considered. Recent examples of advances in electrospray ionization and sampling for mass spectrometry with nanopipettes is discussed. These examples show a scientific intersection that is ripe for further development.
Collapse
Affiliation(s)
- Lane A Baker
- Indiana University, Department of Chemistry, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA
| | - Gargi S Jagdale
- Indiana University, Department of Chemistry, 800 E. Kirkwood Avenue, Bloomington, IN 47405, USA
| |
Collapse
|
32
|
Rahman MM, Chingin K, Chen H. Online desalting and sequential formation of analyte ions for mass spectrometry characterization of untreated biological samples. Chem Commun (Camb) 2019; 55:9188-9191. [DOI: 10.1039/c9cc04705k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Current-limited high voltage polarity reversing nanoelectrospray ionization allows online separation of intrinsic metal ions in complex biological samples, resulting in the generation of protonated analytes without interference from salt cations.
Collapse
Affiliation(s)
- Md. Matiur Rahman
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| | - Huanwen Chen
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation
- East China University of Technology
- Nanchang 330013
- China
| |
Collapse
|
33
|
Yu R, Ying Y, Gao R, Long Y. Detektieren mit Nanopipetten im eingeschränkten Raum: von einzelnen Molekülen über Nanopartikel hin zu der Zelle. Angew Chem Int Ed Engl 2018. [DOI: 10.1002/ange.201803229] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Ru‐Jia Yu
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 VR China
| | - Yi‐Lun Ying
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 VR China
| | - Rui Gao
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 VR China
| | - Yi‐Tao Long
- Key Laboratory for Advanced MaterialsSchool of Chemistry & Molecular EngineeringEast China University of Science and Technology Shanghai 200237 VR China
| |
Collapse
|
34
|
Kenderdine T, Xia Z, Williams ER, Fabris D. Submicrometer Nanospray Emitters Provide New Insights into the Mechanism of Cation Adduction to Anionic Oligonucleotides. Anal Chem 2018; 90:13541-13548. [PMID: 30351906 DOI: 10.1021/acs.analchem.8b03632] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The electrospray-MS analysis of oligonucleotides is hampered by nonvolatile metal cations, which may produce adducts responsible for signal suppression and loss of resolution. Alternative to replacing metal cations with MS-friendly ammonium, we explored the utilization of nanospray emitters with submicrometer-diameter tips, which was shown to benefit the analysis of protein samples containing elevated salt concentrations. We demonstrated that such benefits are not limited to proteins, but extend also to oligonucleotide samples analyzed in the negative ion mode. At elevated Na+/Mg2+ concentrations, submicrometer tips produced significantly greater signal-to-noise ratios, as well as greatly reduced adducts and salt clusters, than observed when utilizing micrometer tips. These effects were marginally affected by emitter composition (i.e., borosilicate versus quartz), but varied according to salt concentration and number of oligonucleotide phosphates. The results confirmed that adduct formation is driven by the concentrating effects of the desolvation process, which leads to greatly increased solute concentrations as the volume of the droplet decreases. The process promotes cation-phosphate interactions that may not have necessarily existed in the initial sample, but nevertheless shape the observed adduct series. Therefore, such series may not accurately reflect the distribution of counterions surrounding the analyte in solution. No adverse effects were noted on specific metal interactions, such as those present in a model drug-DNA assembly. These observations indicate that the utilization of submicrometer tips represents an excellent alternative to traditional ammonium-replacement approaches, which enables the analysis of oligonucleotides in the presence of Na+/Mg2+ concentrations capable of preserving their structure and functional properties.
Collapse
Affiliation(s)
- Thomas Kenderdine
- Department of Chemistry , University at Albany , Albany , New York 12222 , United States
| | - Zijie Xia
- Department of Chemistry , University of California-Berkeley , Berkeley , California 94720-1460 , United States
| | - Evan R Williams
- Department of Chemistry , University of California-Berkeley , Berkeley , California 94720-1460 , United States
| | - Daniele Fabris
- Department of Chemistry , University at Albany , Albany , New York 12222 , United States.,The RNA Institute , University at Albany , Albany , New York 12222 , United States
| |
Collapse
|
35
|
Ion concentration in micro and nanoscale electrospray emitters. Anal Bioanal Chem 2018; 410:3639-3648. [PMID: 29704029 DOI: 10.1007/s00216-018-1043-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2018] [Revised: 03/19/2018] [Accepted: 03/22/2018] [Indexed: 10/17/2022]
Abstract
Solution-phase ion transport during electrospray has been characterized for nanopipettes, or glass capillaries pulled to nanoscale tip dimensions, and micron-sized electrospray ionization emitters. Direct visualization of charged fluorophores during the electrospray process is used to evaluate impacts of emitter size, ionic strength, analyte size, and pressure-driven flow on heterogeneous ion transport during electrospray. Mass spectrometric measurements of positively- and negatively-charged proteins were taken for micron-sized and nanopipette emitters under low ionic strength conditions to further illustrate a discrepancy in solution-driven transport of charged analytes. A fundamental understanding of analyte electromigration during electrospray, which is not always considered, is expected to provide control over selective analyte depletion and enrichment, and can be harnessed for sample cleanup. Graphical abstract Fluorescence micrographs of ion migration in nanoscale pipettes while solution is electrosprayed.
Collapse
|
36
|
Susa AC, Lippens JL, Xia Z, Loo JA, Campuzano IDG, Williams ER. Submicrometer Emitter ESI Tips for Native Mass Spectrometry of Membrane Proteins in Ionic and Nonionic Detergents. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:203-206. [PMID: 29027132 PMCID: PMC5786471 DOI: 10.1007/s13361-017-1793-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Revised: 08/21/2017] [Accepted: 08/23/2017] [Indexed: 05/11/2023]
Abstract
Native mass spectrometry (native-MS) of membrane proteins typically requires a detergent screening protocol, protein solubilization in the preferred detergent, followed by protein liberation from the micelle by collisional activation. Here, submicrometer nano-ESI emitter tips are used for native-MS of membrane proteins solubilized in both nonionic and ionic detergent solutions. With the submicrometer nano-ESI emitter tips, resolved charge-state distributions of membrane protein ions are obtained from a 150 mM NaCl, 25 mM Tris-HCl with 1.1% octyl glucoside solution. The relative abundances of NaCl and detergent cluster ions at high m /z are significantly reduced with the submicrometer emitters compared with larger nano-ESI emitters that are commonly used. This technique is beneficial for significantly decreasing the abundances (by two to three orders of magnitude compared with the larger tip size: 1.6 μm) of detergent cluster ions formed from aqueous ammonium acetate solutions containing detergents that can overlap with the membrane protein ion signal. Resolved charge-state distributions of membrane protein ions from aqueous ammonium acetate solutions containing ionic detergents were obtained with the submicrometer nano-ESI emitters; this is the first report of native-MS of membrane proteins solubilized by ionic detergents. Graphical Abstract.
Collapse
Affiliation(s)
- Anna C Susa
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA
| | | | - Zijie Xia
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA
| | - Joseph A Loo
- Department of Chemistry and Biochemistry, and Department of Biological Chemistry, University of California-Los Angeles, Los Angeles, CA, 90095, USA
| | | | - Evan R Williams
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA.
| |
Collapse
|
37
|
Xia Z, Williams ER. Protein-Glass Surface Interactions and Ion Desalting in Electrospray Ionization with Submicron Emitters. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:194-202. [PMID: 29027129 DOI: 10.1007/s13361-017-1825-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Revised: 09/28/2017] [Accepted: 09/28/2017] [Indexed: 05/27/2023]
Abstract
Theta glass electrospray emitters can rapidly mix solutions to investigate fast reactions that occur as quickly as 1 μs, but emitters with submicron tips have the unusual properties of desalting protein ions and affecting the observed abundances of some proteins as a result of protein-surface interactions. The role of protein physical properties on ion signal was investigated using 1.7 ± 0.1 μm and 269 ± 7 nm emitters and 100 mM aqueous ammonium acetate or ammonium bicarbonate solutions. Protein ion desalting occurs for both positive and negative ions. The signal of a mixture of proteins with the 269 nm tips is time-dependent and the order in which ions of each protein is observed is related to the expected strengths of the protein-surface interactions. These results indicate that it is not just the high surface-to-volume ratio that plays a role in protein adsorption and reduction or absence of initial ion signal, but the small diffusion distance and extremely low flow rates of the smaller emitters can lead to complete adsorption of some proteins and loss of signal until the adsorption sites are filled and the zeta potential is significantly reduced. After about 30 min, signals for a protein mixture from the two different size capillaries are similar. These results show the advantages of submicron emitters but also indicate that surface effects must be taken into account in experiments using such small tips or that coating the emitter surface to prevent adsorption should be considered. Graphical Abstract.
Collapse
Affiliation(s)
- Zije Xia
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA
| | - Evan R Williams
- Department of Chemistry, University of California, Berkeley, CA, 94720-1460, USA.
| |
Collapse
|
38
|
Zhang Z, Zhang Z, Liu H, Mao X, Liu W, Zhang S, Nie Z, Lu X. Ultratrace and robust visual sensor of Cd 2+ ions based on the size-dependent optical properties of Au@g-CNQDs nanoparticles in mice models. Biosens Bioelectron 2017; 103:87-93. [PMID: 29278816 DOI: 10.1016/j.bios.2017.12.025] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2017] [Revised: 12/07/2017] [Accepted: 12/17/2017] [Indexed: 12/24/2022]
Abstract
Visual inspection is expected as an ideal technique, which can directly and conveniently detect heavy metal ions by observing the color change. Insensitivity of detecting weakly colored heavy transition metal ions and low adsorptivity of metal ions on nanoparticle surface are two main factors hindering the application of visual detection in heavy metal ions detection. Herein, we demonstrated an operational colorimetric sensor based on the color dependence of nanoparticles aggregation to selective and facile detect weakly colored transition heavy metal Cd2+ ions that have been considered as the origin of the "Itai-itai" disease. Uniform colloidal 15nm graphite-like nitride doped carbon quantum dots-capped gold nanoparticle (Au@g-CNQDs) was successfully prepared, wherein the existence of numerous heptazine, carboxyl and hydroxyl groups on the nanoparticle's surface strengthened adsorption of the Cd2+ ions on the surface of Au@g-CNQDs through the "cooperative effect". As a consequence, without expensive and intricate exogenous indicators or other special additives, the Cd2+ ions could sensitively and quickly captured to detect at ultra-low concentration within 30s by the naked-eye. Under the optimal conditions, the Cd2+ ions sensor possesses good analytical performances with a wide linear range of 0.01-3.0μM and a detection limit of 10nM (S/N = 3). Moreover, the biodistribution and aggregation of Cd2+ ions were detected effectively in mice organ tissues suggesting its great potential use for real-word applications.
Collapse
Affiliation(s)
- Zhuoyue Zhang
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China
| | - Zhen Zhang
- Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, Tianjin University, Tianjin 300072, PR China
| | - Huihui Liu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, PR China
| | - Xiang Mao
- Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, Tianjin University, Tianjin 300072, PR China
| | - Wei Liu
- Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, Tianjin University, Tianjin 300072, PR China
| | - Shouting Zhang
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China; Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, Tianjin University, Tianjin 300072, PR China
| | - Zongxiu Nie
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, PR China
| | - Xiaoquan Lu
- Key Laboratory of Bioelectrochemistry & Environmental Analysis of Gansu Province, College of Chemistry & Chemical Engineering, Northwest Normal University, Lanzhou 730070, PR China; Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, Tianjin University, Tianjin 300072, PR China.
| |
Collapse
|
39
|
Susa AC, Xia Z, Williams ER. Native Mass Spectrometry from Common Buffers with Salts That Mimic the Extracellular Environment. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201702330] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Affiliation(s)
- Anna C. Susa
- Department of Chemistry; University of California, Berkeley, California; B42 Hildebrand Hall Berkeley CA 94720 USA
| | - Zijie Xia
- Department of Chemistry; University of California, Berkeley, California; B42 Hildebrand Hall Berkeley CA 94720 USA
| | - Evan R. Williams
- Department of Chemistry; University of California, Berkeley, California; B42 Hildebrand Hall Berkeley CA 94720 USA
| |
Collapse
|
40
|
Susa AC, Xia Z, Williams ER. Native Mass Spectrometry from Common Buffers with Salts That Mimic the Extracellular Environment. Angew Chem Int Ed Engl 2017; 56:7912-7915. [DOI: 10.1002/anie.201702330] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2017] [Indexed: 12/18/2022]
Affiliation(s)
- Anna C. Susa
- Department of Chemistry; University of California, Berkeley, California; B42 Hildebrand Hall Berkeley CA 94720 USA
| | - Zijie Xia
- Department of Chemistry; University of California, Berkeley, California; B42 Hildebrand Hall Berkeley CA 94720 USA
| | - Evan R. Williams
- Department of Chemistry; University of California, Berkeley, California; B42 Hildebrand Hall Berkeley CA 94720 USA
| |
Collapse
|