1
|
Guglielmotti V, Fuhry E, Neubert TJ, Kuhl M, Pallarola D, Balasubramanian K. Real-Time Monitoring of Cell Adhesion onto a Soft Substrate by a Graphene Impedance Biosensor. ACS Sens 2024; 9:101-109. [PMID: 38141037 DOI: 10.1021/acssensors.3c01705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
Soft substrates are interesting for many applications, ranging from mimicking the cellular microenvironment to implants. Conductive electrodes on such substrates allow the realization of flexible, elastic, and transparent sensors. Single-layer graphene as a candidate for such electrodes brings the advantage that the active area of the sensor is transparent and conformal to the underlying substrate. Here, we overcome several challenges facing the routine realization of graphene cell sensors on a canonical soft substrate, namely, poly(dimethylsiloxane) (PDMS). We have systematically studied the effect of surface energy before, during, and after the transfer of graphene. Thus, we have identified a suitable support polymer, optimal substrate (pre)treatment, and an appropriate solvent for the removal of the support. Using this procedure, we can reproducibly obtain stable and intact graphene sensors on a millimeter scale on PDMS, which can withstand continuous measurements in cell culture media for several days. From local nanomechanical measurements, we infer that the softness of the substrate is slightly affected after the graphene transfer. However, we can modulate the stiffness using PDMS with differing compositions. Finally, we show that graphene sensors on PDMS can be successfully used as soft electrodes for real-time monitoring of the cell adhesion kinetics. The routine availability of single-layer graphene electrodes on a soft substrate with tunable stiffness will open a new avenue for studies, where the PDMS-liquid interface is made conducting with minimal alteration of the intrinsic material properties such as softness, flexibility, elasticity, and transparency.
Collapse
Affiliation(s)
- Victoria Guglielmotti
- Department of Chemistry, School of Analytical Sciences Adlershof (SALSA) & IRIS Adlershof, Humboldt-Universität zu Berlin, Berlin 10099, Germany
- Instituto de Nanosistemas, Universidad Nacional de General San Martín, San Martín 1650, Provincia de Buenos Aires, Argentina
| | - Emil Fuhry
- Department of Chemistry, School of Analytical Sciences Adlershof (SALSA) & IRIS Adlershof, Humboldt-Universität zu Berlin, Berlin 10099, Germany
| | - Tilmann J Neubert
- Department of Chemistry, School of Analytical Sciences Adlershof (SALSA) & IRIS Adlershof, Humboldt-Universität zu Berlin, Berlin 10099, Germany
| | - Michel Kuhl
- Department of Chemistry, School of Analytical Sciences Adlershof (SALSA) & IRIS Adlershof, Humboldt-Universität zu Berlin, Berlin 10099, Germany
| | - Diego Pallarola
- Instituto de Nanosistemas, Universidad Nacional de General San Martín, San Martín 1650, Provincia de Buenos Aires, Argentina
| | - Kannan Balasubramanian
- Department of Chemistry, School of Analytical Sciences Adlershof (SALSA) & IRIS Adlershof, Humboldt-Universität zu Berlin, Berlin 10099, Germany
| |
Collapse
|
2
|
Arman S, Tilley RD, Gooding JJ. A review of electrochemical impedance as a tool for examining cell biology and subcellular mechanisms: merits, limits, and future prospects. Analyst 2024; 149:269-289. [PMID: 38015145 DOI: 10.1039/d3an01423a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
Herein the development of cellular impedance biosensors, electrochemical impedance spectroscopy, and the general principles and terms associated with the cell-electrode interface is reviewed. This family of techniques provides quantitative and sensitive information into cell responses to stimuli in real-time with high temporal resolution. The applications of cell-based impedance biosensors as a readout in cell biology is illustrated with a diverse range of examples. The current state of the field, its limitations, the possible available solutions, and the potential benefits of developing biosensors are discussed.
Collapse
Affiliation(s)
- Seyedyousef Arman
- School of Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia.
- Australia Centre for Nanomedicine, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Richard D Tilley
- School of Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia.
- Electron Microscope Unit, Mark Wainwright Analytical Centre, The University of New South Wales, Sydney, New South Wales 2052, Australia
| | - J Justin Gooding
- School of Chemistry, The University of New South Wales, Sydney, New South Wales 2052, Australia.
- Australia Centre for Nanomedicine, The University of New South Wales, Sydney, New South Wales 2052, Australia
| |
Collapse
|
3
|
Nazari H, Shrestha J, Naei VY, Bazaz SR, Sabbagh M, Thiery JP, Warkiani ME. Advances in TEER measurements of biological barriers in microphysiological systems. Biosens Bioelectron 2023; 234:115355. [PMID: 37159988 DOI: 10.1016/j.bios.2023.115355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 03/10/2023] [Accepted: 04/25/2023] [Indexed: 05/11/2023]
Abstract
Biological barriers are multicellular structures that precisely regulate the transport of ions, biomolecules, drugs, cells, and other organisms. Transendothelial/epithelial electrical resistance (TEER) is a label-free method for predicting the properties of biological barriers. Understanding the mechanisms that control TEER significantly enhances our knowledge of the physiopathology of different diseases and aids in the development of new drugs. Measuring TEER values within microphysiological systems called organ-on-a-chip devices that simulate the microenvironment, architecture, and physiology of biological barriers in the body provides valuable insight into the behavior of barriers in response to different drugs and pathogens. These integrated systems should increase the accuracy, reproducibility, sensitivity, resolution, high throughput, speed, cost-effectiveness, and reliable predictability of TEER measurements. Implementing advanced micro and nanoscale manufacturing techniques, surface modification methods, biomaterials, biosensors, electronics, and stem cell biology is necessary for integrating TEER measuring systems with organ-on-chip technology. This review focuses on the applications, advantages, and future perspectives of integrating organ-on-a-chip technology with TEER measurement methods for studying biological barriers. After briefly reviewing the role of TEER in the physiology and pathology of barriers, standard techniques for measuring TEER, including Ohm's law and impedance spectroscopy, and commercially available devices are described. Furthermore, advances in TEER measurement are discussed in multiple barrier-on-a-chip system models representing different organs. Finally, we outline future trends in implementing advanced technologies to design and fabricate nanostructured electrodes, complicated microfluidic chips, and membranes for more advanced and accurate TEER measurements.
Collapse
Affiliation(s)
- Hojjatollah Nazari
- School of Biomedical Engineering, University of Technology Sydney, Sydney, 2007, New South Wales, Australia
| | - Jesus Shrestha
- School of Biomedical Engineering, University of Technology Sydney, Sydney, 2007, New South Wales, Australia
| | - Vahid Yaghoubi Naei
- School of Biomedical Engineering, University of Technology Sydney, Sydney, 2007, New South Wales, Australia
| | - Sajad Razavi Bazaz
- School of Biomedical Engineering, University of Technology Sydney, Sydney, 2007, New South Wales, Australia
| | - Milad Sabbagh
- School of Biomedical Engineering, University of Technology Sydney, Sydney, 2007, New South Wales, Australia
| | | | - Majid Ebrahimi Warkiani
- School of Biomedical Engineering, University of Technology Sydney, Sydney, 2007, New South Wales, Australia; Institute of Molecular Medicine, Sechenov University, 119991, Moscow, Russia.
| |
Collapse
|
4
|
Pospíšil J, Hrabovský M, Bohačiaková D, Hovádková Z, Jurásek M, Mlčoušková J, Paruch K, Nevolová Š, Damborsky J, Hampl A, Jaros J. Geometric Control of Cell Behavior by Biomolecule Nanodistribution. ACS Biomater Sci Eng 2022; 8:4789-4806. [PMID: 36202388 PMCID: PMC9667466 DOI: 10.1021/acsbiomaterials.2c00650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
![]()
Many dynamic interactions within the cell microenvironment
modulate
cell behavior and cell fate. However, the pathways and mechanisms
behind cell–cell or cell–extracellular matrix interactions
remain understudied, as they occur at a nanoscale level. Recent progress
in nanotechnology allows for mimicking of the microenvironment at
nanoscale in vitro; electron-beam lithography (EBL)
is currently the most promising technique. Although this nanopatterning
technique can generate nanostructures of good quality and resolution,
it has resulted, thus far, in the production of only simple shapes
(e.g., rectangles) over a relatively small area (100 × 100 μm),
leaving its potential in biological applications unfulfilled. Here,
we used EBL for cell-interaction studies by coating cell-culture-relevant
material with electron-conductive indium tin oxide, which formed nanopatterns
of complex nanohexagonal structures over a large area (500 ×
500 μm). We confirmed the potential of EBL for use in cell-interaction
studies by analyzing specific cell responses toward differentially
distributed nanohexagons spaced at 1000, 500, and 250 nm. We found
that our optimized technique of EBL with HaloTags enabled the investigation
of broad changes to a cell-culture-relevant surface and can provide
an understanding of cellular signaling mechanisms at a single-molecule
level.
Collapse
Affiliation(s)
- Jakub Pospíšil
- Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic.,Core Facility Cellular Imaging, CEITEC, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic
| | - Miloš Hrabovský
- TESCAN Orsay Holding a.s., Libušina tř. 863, Brno 623 00, Czech Republic
| | - Dáša Bohačiaková
- Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic.,International Clinical Research Center (ICRC), St. Anne's University Hospital, Pekařská 53, Brno 656 91, Czech Republic
| | | | | | - Jarmila Mlčoušková
- Department of Biology, Faculty of Medicine, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic
| | - Kamil Paruch
- International Clinical Research Center (ICRC), St. Anne's University Hospital, Pekařská 53, Brno 656 91, Czech Republic.,Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic
| | - Šárka Nevolová
- International Clinical Research Center (ICRC), St. Anne's University Hospital, Pekařská 53, Brno 656 91, Czech Republic.,Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Kamenice 5, Brno 625 00, Czech Republic
| | - Jiri Damborsky
- International Clinical Research Center (ICRC), St. Anne's University Hospital, Pekařská 53, Brno 656 91, Czech Republic.,Loschmidt Laboratories, Department of Experimental Biology and Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Kamenice 5, Brno 625 00, Czech Republic
| | - Aleš Hampl
- Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic.,International Clinical Research Center (ICRC), St. Anne's University Hospital, Pekařská 53, Brno 656 91, Czech Republic
| | - Josef Jaros
- Department of Histology and Embryology, Faculty of Medicine, Masaryk University, Kamenice 5, Brno 625 00, Czech Republic.,International Clinical Research Center (ICRC), St. Anne's University Hospital, Pekařská 53, Brno 656 91, Czech Republic
| |
Collapse
|
5
|
Guglielmotti V, Saffioti NA, Tohmé AL, Gambarotta M, Corthey G, Pallarola D. A portable and affordable aligner for the assembly of microfluidic devices. HARDWAREX 2022; 12:e00348. [PMID: 36105917 PMCID: PMC9465365 DOI: 10.1016/j.ohx.2022.e00348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 08/09/2022] [Accepted: 08/16/2022] [Indexed: 06/15/2023]
Abstract
The incorporation of sophisticated capabilities within microfluidic devices often requires the assembly of different layers in a correct arrangement. For example, when it is desired to include electrodes inside microfluidic channels or to create 3D microfluidic structures. However, the alignment between different substrates at the microscale requires expensive equipment not available for all research groups. In this work, we present an affordable, compact and portable aligner for assembling multilayered composite microfluidic chips. The instrument is composed of aluminum machined pieces combined with precision stages and includes a digital microscope with a LED illumination system for monitoring the alignment process. An interchangeable holder was created for substrate fixing, allowing the bonding of PDMS with other materials. Microscopic visualization is achieved through any device with internet access, avoiding the need of a computer attached to the aligner. To test the performance of the aligner, the center of an indium tin oxide microelectrode on a glass substrate was aligned with the center of a microchannel in a PDMS chip. The accuracy and precision of the instrument are suited for many microfluidic applications. The small and inexpensive design of the aligner makes it a cost-effective option for small groups working in microfluidics.
Collapse
|
6
|
The biomedical significance of multifunctional nanobiomaterials: The key components for site-specific delivery of therapeutics. Life Sci 2021; 277:119400. [PMID: 33794255 DOI: 10.1016/j.lfs.2021.119400] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 03/08/2021] [Accepted: 03/13/2021] [Indexed: 01/07/2023]
Abstract
The emergence of nanotechnology has provided the possibilities to overcome the potential problems associated with the development of pharmaceuticals including the low solubility, non-specific cellular uptake or action, and rapid clearance. Regarding the biomaterials (BMs), huge efforts have been made for improving their multi-functionalities via incorporation of various nanomaterials (NMs). Nanocomposite hydrogels with suitable properties could exhibit a variety of beneficial effects in biomedicine particularly in the delivery of therapeutics or tissue engineering. NMs including the silica- or carbon-based ones are capable of integration into various BMs that might be due to their special compositions or properties such as the hydrophilicity, hydrophobicity, magnetic or electrical characteristics, and responsiveness to various stimuli. This might provide multi-functional nanobiomaterials against a wide variety of disorders. Meanwhile, inappropriate distribution or penetration into the cells or tissues, bio-nano interface complexity, targeting ability loss, or any other unpredicted phenomena are the serious challenging issues. Computational simulations and models enable development of NMs with optimal characteristics and provide a deeper knowledge of NM interaction with biosystems. This review highlights the biomedical significance of the multifunctional NMs particularly those applied for the development of 2-D or 3-D BMs for a variety of applications including the site-specific delivery of therapeutics. The powerful impacts of the computational techniques on the design process of NMs, quantitation and prediction of protein corona formation, risk assessment, and individualized therapy for improved therapeutic outcomes have also been discussed.
Collapse
|
7
|
Saffioti NA, Cavalcanti-Adam EA, Pallarola D. Biosensors for Studies on Adhesion-Mediated Cellular Responses to Their Microenvironment. Front Bioeng Biotechnol 2020; 8:597950. [PMID: 33262979 PMCID: PMC7685988 DOI: 10.3389/fbioe.2020.597950] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 10/12/2020] [Indexed: 12/28/2022] Open
Abstract
Cells interact with their microenvironment by constantly sensing mechanical and chemical cues converting them into biochemical signals. These processes allow cells to respond and adapt to changes in their environment, and are crucial for most cellular functions. Understanding the mechanism underlying this complex interplay at the cell-matrix interface is of fundamental value to decipher key biochemical and mechanical factors regulating cell fate. The combination of material science and surface chemistry aided in the creation of controllable environments to study cell mechanosensing and mechanotransduction. Biologically inspired materials tailored with specific bioactive molecules, desired physical properties and tunable topography have emerged as suitable tools to study cell behavior. Among these materials, synthetic cell interfaces with built-in sensing capabilities are highly advantageous to measure biophysical and biochemical interaction between cells and their environment. In this review, we discuss the design of micro and nanostructured biomaterials engineered not only to mimic the structure, properties, and function of the cellular microenvironment, but also to obtain quantitative information on how cells sense and probe specific adhesive cues from the extracellular domain. This type of responsive biointerfaces provides a readout of mechanics, biochemistry, and electrical activity in real time allowing observation of cellular processes with molecular specificity. Specifically designed sensors based on advanced optical and electrochemical readout are discussed. We further provide an insight into the emerging role of multifunctional micro and nanosensors to control and monitor cell functions by means of material design.
Collapse
Affiliation(s)
- Nicolás Andrés Saffioti
- Instituto de Nanosistemas, Universidad Nacional de General San Martín, San Martín, Argentina
| | | | - Diego Pallarola
- Instituto de Nanosistemas, Universidad Nacional de General San Martín, San Martín, Argentina
| |
Collapse
|
8
|
Zamanifard M, Khorasani MT, Daliri M, Parvazinia M. Preparation and modeling of electrospun polyhydroxybutyrate/polyaniline composite scaffold modified by plasma and printed by an inkjet method and its cellular study. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2020; 31:1515-1537. [PMID: 32403986 DOI: 10.1080/09205063.2020.1764162] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The reconstruction of the nerve tissue engineering scaffold is always of particular interest due to the inability to recover and repair neural tissues after being damaged by diseases or physical injuries. The primary purpose of this study was obtaining a model used to predict the diameter of the fibers of electrospun polyhydroxybutyrate (PHB) scaffolds. Accordingly, the range of operating parameters, namely the applied voltage, the distance between the nozzle to the collector, and solution concentration, was designed for the electrospinning process at three different levels, giving seventeen experiments. These data were modeled utilizing response surface methodology and artificial neural network method using Design Expert and Matlab software.The effect of process parameters on the diameter, as well as their interactions were investigated in detail, and the corresponding models were suggested. Both the RSM and ANN models showed an excellent agreement between the experimental and predicted response values. In the second phase of the study, PHB natural polymer was electrospun into scaffolds with high biocompatibility, resulting in a 224-360 nm diameter range .To further modify the scaffold in order to improve the compatibility of PHB, the fibrous surface of scaffolds was exposed to oxygenated plasma gas radiation under controlled conditions. Next, polyaniline (PANI) nanoparticles were then synthesized and printed on the surface of scaffolds as parallel lines. Then samples were exposed to the electric field. Fourier-transform infrared spectroscopy, water contact angle, optical and electron microscopy, tensile test, and cell viability analysis were performed to study properties of resulting scaffolds. The results indicated the fact that modification of the scaffolds by oxygen plasma and printing PANI nanoparticles in particular patterns had a favorable impact on cell adhesion and direction of cell growth, showing the potential of resulting scaffolds for nerve tissue engineering applications.
Collapse
Affiliation(s)
- Mohammad Zamanifard
- Department of Biomaterials, Faculty of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | | | - Morteza Daliri
- Department of Animal and Marine Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran
| | - Mahmoud Parvazinia
- Department of Polymerization Engineering, Iran Polymer and Petrochemical Institute, Tehran, Iran
| |
Collapse
|
9
|
Neumann HR, Selhuber-Unkel C. High-throughput micro-nanostructuring by microdroplet inkjet printing. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2018; 9:2372-2380. [PMID: 30254832 PMCID: PMC6142749 DOI: 10.3762/bjnano.9.222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 08/16/2018] [Indexed: 06/08/2023]
Abstract
The production of micrometer-sized structures comprised of nanoparticles in defined patterns and densities is highly important in many fields, ranging from nano-optics to biosensor technologies and biomaterials. A well-established method to fabricate quasi-hexagonal patterns of metal nanoparticles is block copolymer micelle nanolithography, which relies on the self-assembly of metal-loaded micelles on surfaces by a dip-coating or spin-coating process. Using this method, the spacing of the nanoparticles is controlled by the size of the micelles and by the coating conditions. Whereas block copolymer micelle nanolithography is a high-throughput method for generating well-ordered nanoparticle patterns at the nanoscale, so far it has been inefficient in generating a hierarchical overlay structure at the micrometer scale. Here, we show that by combining block copolymer micelle nanolithography with inkjet printing, hierarchical patterns of gold nanoparticles in the form of microstructures can be achieved in a high-throughput process. Inkjet printing was used to generate droplets of the micelle solution on surfaces, resulting in printed circles that contain patterns of gold nanoparticles with an interparticle spacing between 25 and 42 nm. We tested this method on different silicon and nickel-titanium surfaces and the generated patterns were found to depend on the material type and surface topography. Based on the presented strategy, we were able to achieve patterning times of a few seconds and produce quasi-hexagonal micro-nanopatterns of gold nanoparticles on smooth surfaces. Hence, this method is a high-throughput method that can be used to coat surfaces with nanoparticles in a user-defined pattern at the micrometer scale. As the nanoparticles provide a chemical contrast on the surface, they can be further functionalized and are therefore highly relevant for biological applications.
Collapse
Affiliation(s)
- Hendrikje R Neumann
- Biocompatible Nanomaterials, Institute for Materials Science, University of Kiel, Kaiserstr. 2, 24143 Kiel, Germany
| | - Christine Selhuber-Unkel
- Biocompatible Nanomaterials, Institute for Materials Science, University of Kiel, Kaiserstr. 2, 24143 Kiel, Germany
| |
Collapse
|
10
|
Tatkiewicz WI, Seras-Franzoso J, Garcia-Fruitós E, Vazquez E, Kyvik AR, Guasch J, Villaverde A, Veciana J, Ratera I. Surface-Bound Gradient Deposition of Protein Nanoparticles for Cell Motility Studies. ACS APPLIED MATERIALS & INTERFACES 2018; 10:25779-25786. [PMID: 29989793 DOI: 10.1021/acsami.8b06821] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
A versatile evaporation-assisted methodology based on the coffee-drop effect is described to deposit nanoparticles on surfaces, obtaining for the first time patterned gradients of protein nanoparticles (pNPs) by using a simple custom-made device. Fully controllable patterns with specific periodicities consisting of stripes with different widths and distinct nanoparticle concentration as well as gradients can be produced over large areas (∼10 cm2) in a fast (up to 10 mm2/min), reproducible, and cost-effective manner using an operational protocol optimized by an evolutionary algorithm. The developed method opens the possibility to decorate surfaces "a-la-carte" with pNPs enabling different categories of high-throughput studies on cell motility.
Collapse
Affiliation(s)
- Witold I Tatkiewicz
- Department of Molecular Nanoscience and Organic Materials , Institut de Ciència de Materials de Barcelona (CSIC) , Campus UAB , 08193 Bellaterra , Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - Joaquin Seras-Franzoso
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - Elena Garcia-Fruitós
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - Esther Vazquez
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - A R Kyvik
- Department of Molecular Nanoscience and Organic Materials , Institut de Ciència de Materials de Barcelona (CSIC) , Campus UAB , 08193 Bellaterra , Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - Judith Guasch
- Department of Molecular Nanoscience and Organic Materials , Institut de Ciència de Materials de Barcelona (CSIC) , Campus UAB , 08193 Bellaterra , Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
- Dynamic Biomaterials for Cancer Immunotherapy , Max Planck Partner Group, ICMAB-CSIC , Campus UAB , 08193 Bellaterra , Spain
| | - Antonio Villaverde
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - Jaume Veciana
- Department of Molecular Nanoscience and Organic Materials , Institut de Ciència de Materials de Barcelona (CSIC) , Campus UAB , 08193 Bellaterra , Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| | - Imma Ratera
- Department of Molecular Nanoscience and Organic Materials , Institut de Ciència de Materials de Barcelona (CSIC) , Campus UAB , 08193 Bellaterra , Spain
- CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) , 08193 Bellaterra , Spain
| |
Collapse
|
11
|
Salazar-Anguiano J, Chávez-López MDG, Zúñiga-García V, Camacho J, Elías-Viñas D. Resistive Part of Impedance as a Possible Indicator of Hepatocellular Carcinoma. Arch Med Res 2018; 49:89-93. [PMID: 29779755 DOI: 10.1016/j.arcmed.2018.04.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 04/13/2018] [Indexed: 02/05/2023]
Abstract
BACKGROUND AND AIMS In this work, the multi-frequency impedance both in normal and liver cancer tissues was studied. This was to investigate the feasibility to detect liver cancer by a low cost, easy to use, and a relatively non-invasive electrical impedance measure technique, and thus potentially improving liver cancer diagnosis. METHODS Hepatocellular carcinoma (HCC) was induced in male Wistar rats by the administration of diethylnitrosamine (DEN) during 16 weeks. The electrical impedances at a frequency sweep of 10-100 KHz in the whole body and 10-60 KHz in the liver were taken at the end of the treatment. RESULTS The electrical impedance showed that the real component values of the impedance change in HCC. In addition, we found that the imaginary component was not associated with HCC. CONCLUSION Our results suggest that the electrical impedance may be used as a diagnostic HCC tool.
Collapse
Affiliation(s)
- Jeny Salazar-Anguiano
- Departamento de Ingeniería Eléctrica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Ciudad de México, México.
| | - María de Guadalupe Chávez-López
- Departamento de Farmacología, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Ciudad de México, México
| | - Violeta Zúñiga-García
- Departamento de Farmacología, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Ciudad de México, México
| | - Javier Camacho
- Departamento de Farmacología, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Ciudad de México, México
| | - David Elías-Viñas
- Departamento de Ingeniería Eléctrica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Ciudad de México, México
| |
Collapse
|