1
|
Ren S, Zhang X, Zhang R, Zhang H, Jiao D, Chang H. A microchip based Z-cell absorbance detector integrating micro-lenses and slits for portable liquid chromatography. J Chromatogr A 2024; 1730:465099. [PMID: 38901298 DOI: 10.1016/j.chroma.2024.465099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 06/11/2024] [Accepted: 06/14/2024] [Indexed: 06/22/2024]
Abstract
A miniaturized microchip-based absorbance detector was developed for portable high-performance liquid chromatography (HPLC) to test glycated hemoglobin (HbA1c). The microchip integrating a Z-shaped cell, two collimating micro-lenses and two ink-filled optical slits is small in size (30 mm × 15 mm × 7 mm). The Z-shaped cell has a cross-sectional size of 500 μm × 500 μm and a physical optical path length of 2 mm. Two collimating micro-lenses were inserted in empty grooves on both sides of the cell, one micro-lens for collimating the initial light and the other for focusing the transmitted light. Optical slits on each end of the cell were used to block the stray light. Therefore, this detector indicated a low stray light level (0.011 %) and noise level (2.5 × 10-4 AU). This detector was applied for the commercial HPLC system to detect HbA1c level, and showed a low limit of detection (0.5 μg/mL) and excellent repeatability (≤ 2.03 %). The sensitivity was enhanced by 3.4 times when the optical path length was increased from 0.5 mm to 2 mm and the stray light was blocked by optical slits. The miniaturized microchip-based absorbance detector developed shows a great potential for application in portable and compact HPLC.
Collapse
Affiliation(s)
- Shuang Ren
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Xiaorui Zhang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Ruirong Zhang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| | - Hantian Zhang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Dezhao Jiao
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China
| | - Honglong Chang
- Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
| |
Collapse
|
2
|
Mika T, Kalnins M, Spalvins K. The use of droplet-based microfluidic technologies for accelerated selection of Yarrowia lipolytica and Phaffia rhodozyma yeast mutants. Biol Methods Protoc 2024; 9:bpae049. [PMID: 39114747 PMCID: PMC11303513 DOI: 10.1093/biomethods/bpae049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 06/24/2024] [Accepted: 07/09/2024] [Indexed: 08/10/2024] Open
Abstract
Microorganisms are widely used for the industrial production of various valuable products, such as pharmaceuticals, food and beverages, biofuels, enzymes, amino acids, vaccines, etc. Research is constantly carried out to improve their properties, mainly to increase their productivity and efficiency and reduce the cost of the processes. The selection of microorganisms with improved qualities takes a lot of time and resources (both human and material); therefore, this process itself needs optimization. In the last two decades, microfluidics technology appeared in bioengineering, which allows for manipulating small particles (from tens of microns to nanometre scale) in the flow of liquid in microchannels. The technology is based on small-volume objects (microdroplets from nano to femtolitres), which are manipulated using a microchip. The chip is made of an optically transparent inert to liquid medium material and contains a series of channels of small size (<1 mm) of certain geometry. Based on the physical and chemical properties of microparticles (like size, weight, optical density, dielectric constant, etc.), they are separated using microsensors. The idea of accelerated selection of microorganisms is the application of microfluidic technologies to separate mutants with improved qualities after mutagenesis. This article discusses the possible application and practical implementation of microfluidic separation of mutants, including yeasts like Yarrowia lipolytica and Phaffia rhodozyma after chemical mutagenesis will be discussed.
Collapse
Affiliation(s)
- Taras Mika
- Institute of Energy Systems and Environment, Riga Technical University, 12 – K1 Āzene street, Riga, LV-1048, Latvia
| | - Martins Kalnins
- Institute of Energy Systems and Environment, Riga Technical University, 12 – K1 Āzene street, Riga, LV-1048, Latvia
| | - Kriss Spalvins
- Institute of Energy Systems and Environment, Riga Technical University, 12 – K1 Āzene street, Riga, LV-1048, Latvia
| |
Collapse
|
3
|
Jain A, Stavrakis S, deMello A. Droplet-based microfluidics and enzyme evolution. Curr Opin Biotechnol 2024; 87:103097. [PMID: 38430713 DOI: 10.1016/j.copbio.2024.103097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Accepted: 02/06/2024] [Indexed: 03/05/2024]
Abstract
Enzymes are widely used as catalysts in the chemical and pharmaceutical industries. While successful in many situations, they must usually be adapted to operate efficiently under nonnatural conditions. Enzyme engineering allows the creation of novel enzymes that are stable at elevated temperatures or have higher activities and selectivities. Current enzyme engineering techniques require the production and testing of enzyme variant libraries to identify members with desired attributes. Unfortunately, traditional screening methods cannot screen such large mutagenesis libraries in a robust and timely manner. Droplet-based microfluidic systems can produce, process, and sort picoliter droplets at kilohertz rates and have emerged as powerful tools for library screening and thus enzyme engineering. We describe how droplet-based microfluidics has been used to advance directed evolution.
Collapse
Affiliation(s)
- Ankit Jain
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| | - Stavros Stavrakis
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| | - Andrew deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland.
| |
Collapse
|
4
|
Lu B, Lunn J, Nightingale AM, Niu X. Highly sensitive absorbance measurement using droplet microfluidics integrated with an oil extraction and long pathlength detection flow cell. Front Chem 2024; 12:1394388. [PMID: 38803381 PMCID: PMC11129082 DOI: 10.3389/fchem.2024.1394388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Accepted: 04/16/2024] [Indexed: 05/29/2024] Open
Abstract
In droplet microfluidics, UV-Vis absorption spectroscopy along with colorimetric assays have been widely used for chemical and biochemical analysis. However, the sensitivity of the measurement can be limited by the short optical pathlength. Here we report a novel design to enhance the sensitivity by removing oil and converting the droplets into a single-phase aqueous flow, which can be measured within a U-shape channel with long optical pathlength. The flow cells were fabricated via 3D printing. The calibration results have demonstrated complete oil removal and effective optical pathlengths similar to the designed channel lengths (from 5 to 20 mm). The flow cell was further employed in a droplet microfluidic-based phosphate sensing system. The measured phosphate levels displayed excellent consistency with data obtained from traditional UV spectroscopy analysis. This flow cell design overcomes the limitations of short optical pathlengths in droplet microfluidics and has the potential to be used for in situ and continuous monitoring.
Collapse
Affiliation(s)
| | | | | | - Xize Niu
- Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom
| |
Collapse
|
5
|
Kurdadze T, Lamadie F, Nehme KA, Teychené S, Biscans B, Rodriguez-Ruiz I. On-Chip Photonic Detection Techniques for Non-Invasive In Situ Characterizations at the Microfluidic Scale. SENSORS (BASEL, SWITZERLAND) 2024; 24:1529. [PMID: 38475065 DOI: 10.3390/s24051529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 03/14/2024]
Abstract
Microfluidics has emerged as a robust technology for diverse applications, ranging from bio-medical diagnostics to chemical analysis. Among the different characterization techniques that can be used to analyze samples at the microfluidic scale, the coupling of photonic detection techniques and on-chip configurations is particularly advantageous due to its non-invasive nature, which permits sensitive, real-time, high throughput, and rapid analyses, taking advantage of the microfluidic special environments and reduced sample volumes. Putting a special emphasis on integrated detection schemes, this review article explores the most relevant advances in the on-chip implementation of UV-vis, near-infrared, terahertz, and X-ray-based techniques for different characterizations, ranging from punctual spectroscopic or scattering-based measurements to different types of mapping/imaging. The principles of the techniques and their interest are discussed through their application to different systems.
Collapse
Affiliation(s)
- Tamar Kurdadze
- CEA, DES, ISEC, DMRC, Univ Montpellier, 30207 Bagnols-sur-Ceze, Marcoule, France
| | - Fabrice Lamadie
- CEA, DES, ISEC, DMRC, Univ Montpellier, 30207 Bagnols-sur-Ceze, Marcoule, France
| | - Karen A Nehme
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| | - Sébastien Teychené
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| | - Béatrice Biscans
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| | - Isaac Rodriguez-Ruiz
- Laboratoire de Génie Chimique, CNRS, UMR 5503, 4 Allée Emile Monso, 31432 Toulouse, France
| |
Collapse
|
6
|
He Y, Qiao Y, Ding L, Cheng T, Tu J. Recent advances in droplet sequential monitoring methods for droplet sorting. BIOMICROFLUIDICS 2023; 17:061501. [PMID: 37969470 PMCID: PMC10645479 DOI: 10.1063/5.0173340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 10/23/2023] [Indexed: 11/17/2023]
Abstract
Droplet microfluidics is an attractive technology to run parallel experiments with high throughput and scalability while maintaining the heterogeneous features of individual samples or reactions. Droplet sorting is utilized to collect the desired droplets based on droplet characterization and in-droplet content evaluation. A proper monitoring method is critical in this process, which governs the accuracy and maximum frequency of droplet handling. Until now, numerous monitoring methods have been integrated in the microfluidic devices for identifying droplets, such as optical spectroscopy, mass spectroscopy, electrochemical monitoring, and nuclear magnetic resonance spectroscopy. In this review, we summarize the features of various monitoring methods integrated into droplet sorting workflow and discuss their suitable condition and potential obstacles in use. We aim to provide a systematic introduction and an application guide for choosing and building a droplet monitoring platform.
Collapse
Affiliation(s)
- Yukun He
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Yi Qiao
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Lu Ding
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Tianguang Cheng
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Jing Tu
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
7
|
Dang Z, Jiang Y, Su X, Wang Z, Wang Y, Sun Z, Zhao Z, Zhang C, Hong Y, Liu Z. Particle Counting Methods Based on Microfluidic Devices. MICROMACHINES 2023; 14:1722. [PMID: 37763885 PMCID: PMC10534595 DOI: 10.3390/mi14091722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 08/30/2023] [Accepted: 08/30/2023] [Indexed: 09/29/2023]
Abstract
Particle counting serves as a pivotal constituent in diverse analytical domains, encompassing a broad spectrum of entities, ranging from blood cells and bacteria to viruses, droplets, bubbles, wear debris, and magnetic beads. Recent epochs have witnessed remarkable progressions in microfluidic chip technology, culminating in the proliferation and maturation of microfluidic chip-based particle counting methodologies. This paper undertakes a taxonomical elucidation of microfluidic chip-based particle counters based on the physical parameters they detect. These particle counters are classified into three categories: optical-based counters, electrical-based particle counters, and other counters. Within each category, subcategories are established to consider structural differences. Each type of counter is described not only in terms of its working principle but also the methods employed to enhance sensitivity and throughput. Additionally, an analysis of future trends related to each counter type is provided.
Collapse
Affiliation(s)
- Zenglin Dang
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Yuning Jiang
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Xin Su
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zhihao Wang
- College of Marine Electrical Engineering, Dalian Maritime University, Dalian 116026, China;
| | - Yucheng Wang
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zhe Sun
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zheng Zhao
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Chi Zhang
- College of Transportation Engineering, Dalian Maritime University, Dalian 116026, China;
| | - Yuming Hong
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| | - Zhijian Liu
- College of Marine Engineering, Dalian Maritime University, Dalian 116026, China; (Z.D.); (Y.J.); (X.S.); (Y.W.); (Z.S.); (Z.Z.); (Y.H.)
| |
Collapse
|
8
|
Mesyngier N, Bailey RC. Multiparametric, Label-Free Analysis of Microfluidic Droplets via a Dynamic Phase Grating Approach. Anal Chem 2023; 95:12605-12612. [PMID: 37585356 DOI: 10.1021/acs.analchem.2c05102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Droplet-based microfluidic systems possess many fundamental advantages as a platform for the analysis of chemical and biological species. However, whereas on-chip operations have rapidly developed over the past decades, approaches for analyzing target molecules within droplets have largely remained limited to methods requiring bulky and expensive instrumentation. In this work, we describe a droplet analysis approach whereby the droplet train itself is the sensing construct. Specifically, the droplet train is interrogated as a transmission phase grating, allowing high-throughput, label-free, solution-phase, and multi-parametric analysis of droplet contents. Importantly, three distinct properties of generated droplets can be simultaneously extracted using this conceptually simple and experimentally straightforward measurement approach. Under constant droplet generation conditions, measurement of droplet viscosity is achieved by monitoring changes in zero order to first order peak separation in the far-field diffraction pattern, with a sensitivity of 2.28 × 10-4 cSt per μm change in peak separation. In parallel, measurement of droplet refractive index (RI) is achieved by measuring changes in the ratio of the zero order to first order peak intensity, with a sensitivity of 2.14 × 10-4 RI units per unit change in a diffracted peak intensity ratio. Finally, droplet generation frequency is determined from the time-varying oscillation of the peak height ratio, yielding comparable results to an expensive high-speed camera commonly used for droplet imaging. Importantly, the experimental strategy for this approach is straightforward and does not require expensive instrumentation; therefore, it may find utility in affordable and portable analysis approaches applied to diverse droplet microfluidic assays.
Collapse
Affiliation(s)
- Nicolas Mesyngier
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Ryan C Bailey
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
9
|
Vasina M, Kovar D, Damborsky J, Ding Y, Yang T, deMello A, Mazurenko S, Stavrakis S, Prokop Z. In-depth analysis of biocatalysts by microfluidics: An emerging source of data for machine learning. Biotechnol Adv 2023; 66:108171. [PMID: 37150331 DOI: 10.1016/j.biotechadv.2023.108171] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/09/2023]
Abstract
Nowadays, the vastly increasing demand for novel biotechnological products is supported by the continuous development of biocatalytic applications which provide sustainable green alternatives to chemical processes. The success of a biocatalytic application is critically dependent on how quickly we can identify and characterize enzyme variants fitting the conditions of industrial processes. While miniaturization and parallelization have dramatically increased the throughput of next-generation sequencing systems, the subsequent characterization of the obtained candidates is still a limiting process in identifying the desired biocatalysts. Only a few commercial microfluidic systems for enzyme analysis are currently available, and the transformation of numerous published prototypes into commercial platforms is still to be streamlined. This review presents the state-of-the-art, recent trends, and perspectives in applying microfluidic tools in the functional and structural analysis of biocatalysts. We discuss the advantages and disadvantages of available technologies, their reproducibility and robustness, and readiness for routine laboratory use. We also highlight the unexplored potential of microfluidics to leverage the power of machine learning for biocatalyst development.
Collapse
Affiliation(s)
- Michal Vasina
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - David Kovar
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - Jiri Damborsky
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - Yun Ding
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Tianjin Yang
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland; Department of Biochemistry, University of Zurich, 8057 Zurich, Switzerland
| | - Andrew deMello
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Stanislav Mazurenko
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic.
| | - Stavros Stavrakis
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland.
| | - Zbynek Prokop
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic.
| |
Collapse
|
10
|
Design and construction of a microfluidics workstation for high-throughput multi-wavelength fluorescence and transmittance activated droplet analysis and sorting. Nat Protoc 2023; 18:1090-1136. [PMID: 36707723 DOI: 10.1038/s41596-022-00796-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 11/09/2022] [Indexed: 01/28/2023]
Abstract
Droplet microfluidics has revolutionized quantitative high-throughput bioassays and screening, especially in the field of single-cell analysis where applications include cell characterization, antibody discovery and directed evolution. However, droplet microfluidic platforms capable of phenotypic, fluorescence-based readouts and sorting are still mostly found in specialized labs, because their setup is complex. Complementary to conventional FACS, microfluidic droplet sorters allow the screening of cell libraries for secreted factors, or even for the effects of secreted or surface-displayed factors on a second cell type. Furthermore, they also enable PCR-activated droplet sorting for the isolation of genetic material harboring specific markers. In this protocol, we provide a detailed step-by-step guide for the construction of a high-throughput droplet analyzer and sorter, which can be accomplished in ~45 working hours by nonspecialists. The resulting instrument is equipped with three lasers to excite the fluorophores in droplets and photosensors that acquire fluorescence signals in the blue (425-465 nm), green (505-545 nm) and red (580-630 nm) spectrum. This instrument also allows transmittance-activated droplet sorting by analyzing the brightfield light intensity transmitting through the droplets. The setup is validated by sorting droplets containing fluorescent beads at 200 Hz with 99.4% accuracy. We show results from an experiment where droplets hosting single cells were sorted on the basis of increased matrix metalloprotease activity as an application of our workstation in single-cell molecular biology, e.g., to analyze molecular determinants of cancer metastasis.
Collapse
|
11
|
Huang C, Jiang Y, Li Y, Zhang H. Droplet Detection and Sorting System in Microfluidics: A Review. MICROMACHINES 2022; 14:mi14010103. [PMID: 36677164 PMCID: PMC9867185 DOI: 10.3390/mi14010103] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/23/2022] [Accepted: 12/26/2022] [Indexed: 05/26/2023]
Abstract
Since being invented, droplet microfluidic technologies have been proven to be perfect tools for high-throughput chemical and biological functional screening applications, and they have been heavily studied and improved through the past two decades. Each droplet can be used as one single bioreactor to compartmentalize a big material or biological population, so millions of droplets can be individually screened based on demand, while the sorting function could extract the droplets of interest to a separate pool from the main droplet library. In this paper, we reviewed droplet detection and active sorting methods that are currently still being widely used for high-through screening applications in microfluidic systems, including the latest updates regarding each technology. We analyze and summarize the merits and drawbacks of each presented technology and conclude, with our perspectives, on future direction of development.
Collapse
Affiliation(s)
- Can Huang
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77842, USA
| | - Yuqian Jiang
- State Key Laboratory of Food Nutrition and Safety, College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Yuwen Li
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77842, USA
| | - Han Zhang
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77842, USA
| |
Collapse
|
12
|
Richter ES, Link A, McGrath JS, Sparrow RW, Gantz M, Medcalf EJ, Hollfelder F, Franke T. Acoustic sorting of microfluidic droplets at kHz rates using optical absorbance. LAB ON A CHIP 2022; 23:195-202. [PMID: 36472476 PMCID: PMC9764809 DOI: 10.1039/d2lc00871h] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 11/28/2022] [Indexed: 05/19/2023]
Abstract
Droplet microfluidics allows one to address the ever-increasing demand to screen large libraries of biological samples. Absorbance spectroscopy complements the golden standard of fluorescence detection by label free target identification and providing more quantifiable data. However, this is limited by speed and sensitivity. In this paper we increase the speed of sorting by including acoustofluidics, achieving sorting rates of target droplets of 1 kHz. We improved the device design for detection of absorbance using fibre-based interrogation of samples with integrated lenses in the microfluidic PDMS device for focusing and collimation of light. This optical improvement reduces the scattering and refraction artefacts, improving the signal quality and sensitivity. The novel design allows us to overcome limitations based on dielectrophoresis sorting, such as droplet size dependency, material and dielectric properties of samples. Our acoustic activated absorbance sorter removes the need for offset dyes or matching oils and sorts about a magnitude faster than current absorbance sorters.
Collapse
Affiliation(s)
- Esther S Richter
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Oakfield Avenue, G12 8LT Glasgow, UK.
| | - Andreas Link
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Oakfield Avenue, G12 8LT Glasgow, UK.
| | - John S McGrath
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Oakfield Avenue, G12 8LT Glasgow, UK.
| | - Raymond W Sparrow
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Oakfield Avenue, G12 8LT Glasgow, UK.
| | - Maximilian Gantz
- Department of Biochemistry, University of Cambridge, Cambridge, CB2 1GA, UK
| | - Elliot J Medcalf
- Department of Biochemistry, University of Cambridge, Cambridge, CB2 1GA, UK
| | - Florian Hollfelder
- Department of Biochemistry, University of Cambridge, Cambridge, CB2 1GA, UK
| | - Thomas Franke
- Division of Biomedical Engineering, School of Engineering, University of Glasgow, Oakfield Avenue, G12 8LT Glasgow, UK.
| |
Collapse
|
13
|
Nnachi RC, Sui N, Ke B, Luo Z, Bhalla N, He D, Yang Z. Biosensors for rapid detection of bacterial pathogens in water, food and environment. ENVIRONMENT INTERNATIONAL 2022; 166:107357. [PMID: 35777116 DOI: 10.1016/j.envint.2022.107357] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 05/10/2022] [Accepted: 06/14/2022] [Indexed: 06/15/2023]
Abstract
Conventional techniques (e.g., culture-based method) for bacterial detection typically require a central laboratory and well-trained technicians, which may take several hours or days. However, recent developments within various disciplines of science and engineering have led to a major paradigm shift in how microorganisms can be detected. The analytical sensors which are widely used for medical applications in the literature are being extended for rapid and on-site monitoring of the bacterial pathogens in food, water and the environment. Especially, within the low-resource settings such as low and middle-income countries, due to the advantages of low cost, rapidness and potential for field-testing, their use is indispensable for sustainable development of the regions. Within this context, this paper discusses analytical methods and biosensors which can be used to ensure food safety, water quality and environmental monitoring. In brief, most of our discussion is focused on various rapid sensors including biosensors and microfluidic chips. The analytical performances such as the sensitivity, specificity and usability of these sensors, as well as a brief comparison with the conventional techniques for bacteria detection, form the core part of the discussion. Furthermore, we provide a holistic viewpoint on how future research should focus on exploring the synergy of different sensing technologies by developing an integrated multiplexed, sensitive and accurate sensors that will enable rapid detection for food safety, water and environmental monitoring.
Collapse
Affiliation(s)
- Raphael Chukwuka Nnachi
- School of Water, Energy and Environment, Cranfield University, Milton Keynes MK43, 0AL, United Kingdom
| | - Ning Sui
- College of Materials Science and Engineering, Qingdao University of Science and Technology, Qingdao 266042, China
| | - Bowen Ke
- Laboratory of Anesthesiology & Critical Care Medicine, Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, Sichuan 61004, PR China
| | - Zhenhua Luo
- School of Water, Energy and Environment, Cranfield University, Milton Keynes MK43, 0AL, United Kingdom
| | - Nikhil Bhalla
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, Shore Road, BT37 0QB Jordanstown, Northern Ireland, United Kingdom; Healthcare Technology Hub, Ulster University, Jordanstown Shore Road, BT37 0QB, Northern Ireland, United Kingdom
| | - Daping He
- School of Science, Wuhan University of Technology, Wuhan 430070, China
| | - Zhugen Yang
- School of Water, Energy and Environment, Cranfield University, Milton Keynes MK43, 0AL, United Kingdom.
| |
Collapse
|
14
|
Taming Taylor-Aris dispersion through chaotic advection. J Chromatogr A 2022; 1673:463110. [DOI: 10.1016/j.chroma.2022.463110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/29/2022] [Accepted: 04/29/2022] [Indexed: 11/22/2022]
|
15
|
Hengoju S, Shvydkiv O, Tovar M, Roth M, Rosenbaum MA. Advantages of optical fibers for facile and enhanced detection in droplet microfluidics. Biosens Bioelectron 2022; 200:113910. [PMID: 34974260 DOI: 10.1016/j.bios.2021.113910] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 12/01/2021] [Accepted: 12/20/2021] [Indexed: 11/02/2022]
Abstract
Droplet microfluidics offers a unique opportunity for ultrahigh-throughput experimentation with minimal sample consumption and thus has obtained increasing attention, particularly for biological applications. Detection and measurements of analytes or biomarkers in tiny droplets are essential for proper analysis of biological and chemical assays like single-cell studies, cytometry, nucleic acid detection, protein quantification, environmental monitoring, drug discovery, and point-of-care diagnostics. Current detection setups widely use microscopes as a central device and other free-space optical components. However, microscopic setups are bulky, complicated, not flexible, and expensive. Furthermore, they require precise optical alignments, specialized optical and technical knowledge, and cumbersome maintenance. The establishment of efficient, simple, and cheap detection methods is one of the bottlenecks for adopting microfluidic strategies for diverse bioanalytical applications and widespread laboratory use. Together with great advances in optofluidic components, the integration of optical fibers as a light guiding medium into microfluidic chips has recently revolutionized analytical possibilities. Optical fibers embedded in a microfluidic platform provide a simpler, more flexible, lower-cost, and sensitive setup for the detection of several parameters from biological and chemical samples and enable widespread, hands-on application much beyond thriving point-of-care developments. In this review, we examine recent developments in droplet microfluidic systems using optical fiber as a light guiding medium, primarily focusing on different optical detection methods such as fluorescence, absorbance, light scattering, and Raman scattering and the potential applications in biochemistry and biotechnology that are and will be arising from this.
Collapse
Affiliation(s)
- Sundar Hengoju
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, 07745, Jena, Germany; Faculty of Biological Sciences, Friedrich Schiller University, 07743, Jena, Germany
| | - Oksana Shvydkiv
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, 07745, Jena, Germany
| | - Miguel Tovar
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, 07745, Jena, Germany
| | - Martin Roth
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, 07745, Jena, Germany
| | - Miriam A Rosenbaum
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology, Hans Knöll Institute, 07745, Jena, Germany; Faculty of Biological Sciences, Friedrich Schiller University, 07743, Jena, Germany.
| |
Collapse
|
16
|
Abstract
Optofluidics represents the interaction of light and fluids on a chip that integrates microfluidics and optics, which provides a promising optical platform for manipulating and analyzing fluid samples. Recent years have witnessed a substantial growth in optofluidic devices, including the integration of optical and fluidic control units, the incorporation of diverse photonic nanostructures, and new applications. All these advancements have enabled the implementation of optofluidics with improved performance. In this review, the recent advances of fabrication techniques and cutting-edge applications of optofluidic devices are presented, with a special focus on the developments of imaging and sensing. Specifically, the optofluidic based imaging techniques and applications are summarized, including the high-throughput cytometry, biochemical analysis, and optofluidic nanoparticle manipulation. The optofluidic sensing section is categorized according to the modulation approaches and the transduction mechanisms, represented by absorption, reflection/refraction, scattering, and plasmonics. Perspectives on future developments and promising avenues in the fields of optofluidics are also provided.
Collapse
|
17
|
Giauque NA, Flowerday CE, Goates SR. Enhanced Fluorescence in a Scattering Medium. APPLIED SPECTROSCOPY 2021; 75:1461-1464. [PMID: 34269092 DOI: 10.1177/00037028211029312] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Often only small amounts of sample are available for spectroscopic analytical determinations. This work investigates the enhancement of signal in columns packed with silica particles. We propose that silica particles cause the light to scatter through the column, effectively increasing optical path length. Packed columns are shown to be effective with fluorescence spectroscopy, but results were inconclusive with absorbance spectroscopy.
Collapse
Affiliation(s)
- Nathan A Giauque
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, USA
| | - Callum E Flowerday
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, USA
| | - Steven R Goates
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, USA
| |
Collapse
|
18
|
Dawson H, Elias J, Etienne P, Calas-Etienne S. The Rise of the OM-LoC: Opto-Microfluidic Enabled Lab-on-Chip. MICROMACHINES 2021; 12:1467. [PMID: 34945317 PMCID: PMC8706692 DOI: 10.3390/mi12121467] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/22/2021] [Accepted: 11/23/2021] [Indexed: 01/04/2023]
Abstract
The integration of optical circuits with microfluidic lab-on-chip (LoC) devices has resulted in a new era of potential in terms of both sample manipulation and detection at the micro-scale. On-chip optical components increase both control and analytical capabilities while reducing reliance on expensive laboratory photonic equipment that has limited microfluidic development. Notably, in-situ LoC devices for bio-chemical applications such as diagnostics and environmental monitoring could provide great value as low-cost, portable and highly sensitive systems. Multiple challenges remain however due to the complexity involved with combining photonics with micro-fabricated systems. Here, we aim to highlight the progress that optical on-chip systems have made in recent years regarding the main LoC applications: (1) sample manipulation and (2) detection. At the same time, we aim to address the constraints that limit industrial scaling of this technology. Through evaluating various fabrication methods, material choices and novel approaches of optic and fluidic integration, we aim to illustrate how optic-enabled LoC approaches are providing new possibilities for both sample analysis and manipulation.
Collapse
|
19
|
Quantitative electrolysis of droplet contents in microfluidic channels. Concept and experimental validation. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.139017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
20
|
Simultaneous Absorbance and Fluorescence Measurements Using an Inlaid Microfluidic Approach. SENSORS 2021; 21:s21186250. [PMID: 34577456 PMCID: PMC8473408 DOI: 10.3390/s21186250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 09/14/2021] [Accepted: 09/15/2021] [Indexed: 11/17/2022]
Abstract
A novel microfluidic optical cell is presented that enables simultaneous measurement of both light absorbance and fluorescence on microlitre volumes of fluid. The chip design is based on an inlaid fabrication technique using clear and opaque poly(methyl methacrylate) or PMMA to create a 20.2 mm long optical cell. The inlaid approach allows fluid interrogation with minimal interference from external light over centimeter long path lengths. The performance of the optical cell is evaluated using a stable fluorescent dye: rhodamine B. Excellent linear relationships (R2 > 0.99) are found for both absorbance and fluorescence over a 0.1-10 µM concentration range. Furthermore, the molar attenuation spectrum is accurately measured over the range 460-550 nm. The approach presented here is applicable to numerous colorimetric- or fluorescence-based assays and presents an important step in the development of multipurpose lab-on-chip sensors.
Collapse
|
21
|
Probst J, Howes P, Arosio P, Stavrakis S, deMello A. Broad-Band Spectrum, High-Sensitivity Absorbance Spectroscopy in Picoliter Volumes. Anal Chem 2021; 93:7673-7681. [PMID: 34009952 DOI: 10.1021/acs.analchem.1c00587] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Picoliter-volume droplets within segmented flows can be probed in a rapid and efficient manner using optical detection methods. To date, however, most detection schemes for droplet content analysis have relied on the use of time-integrated fluorescence measurements. Despite its undoubted utility, the implementation of absorbance-based detectors is particularly challenging due to the reduced optical path lengths that are characteristic of microfluidic systems and deleterious scattering at droplet-oil interfaces. Unsurprisingly, efforts to develop sensitive absorbance-based detection schemes for the interrogation of rapidly moving droplets have primarily focused on ensuring adequate analytical sensitivity and, to date, have been exclusively limited to single-wavelength measurements. To address this limitation, and expand the information content associated with absorbance measurements on-chip, we herein describe a detection scheme for the extraction of broad-band absorbance spectra from pL-volume droplets with high sensitivity. The combination of a confocal optical system (that confines incident light to a reduced detection volume) and a postprocessing algorithm (that effectively removes the contribution of the carrier oil from the extracted spectra) engenders significant improvements in signal-to-noise ratios. Our system is initially calibrated by acquiring absorbance spectra from aqueous solutions of fluorescein isothiocyanate. These measurements confirm both excellent linearity over the studied range (from 0 to 100 μM) and a concentration limit of detection of 800 nM. The methodology is then used to monitor the salt-induced aggregation of gold nanoparticles with millisecond time resolution. This approach for small-volume absorbance spectroscopy allows for both high-throughput and high-information content measurements in subnanoliter volumes and will be highly desirable in a wide variety of bioanalytical applications where sensitivity and throughput are priorities.
Collapse
Affiliation(s)
- Julie Probst
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| | - Philip Howes
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| | - Paolo Arosio
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| | - Stavros Stavrakis
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| | - Andrew deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland
| |
Collapse
|
22
|
Delahaye T, Lombardo T, Sella C, Thouin L. Electrochemical assessments of droplet contents in microfluidic channels. Application to the titration of heterogeneous droplets. Anal Chim Acta 2021; 1155:338344. [PMID: 33766324 DOI: 10.1016/j.aca.2021.338344] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 01/15/2021] [Accepted: 02/17/2021] [Indexed: 01/08/2023]
Abstract
Series of aqueous droplets containing redox species were generated on-demand in a microfluidic channel and detected downstream by an electrochemical cell. Depending on the cell geometry, amperometric detections were performed to simultaneously determine the velocity, volume and content of circulating droplets in oil. Volumes and velocities were estimated from specific transition times on the chronoamperometric responses, while charge were evaluated from current integration. The results showed that the total charge within droplets was controlled by the geometry of the electrochemical cell and droplet velocity, leading to accurate determinations of droplet content under specific operating conditions. An active merging of droplets with titrating solutions was tested for analytical purposes. The results demonstrated that even if the mixing was not complete during detection, the assessment of droplet content was still valid. The performance of electrochemical detection was thus evidenced to determine the content of heterogeneous droplets. This property is pertinent since the design of sophisticated circuits is no longer required to fully homogenize the droplet content before characterization, opening broader perspectives in droplet-based microfluidics.
Collapse
Affiliation(s)
- Thomas Delahaye
- PASTEUR, Département de Chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France
| | - Teo Lombardo
- PASTEUR, Département de Chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France
| | - Catherine Sella
- PASTEUR, Département de Chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France
| | - Laurent Thouin
- PASTEUR, Département de Chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France.
| |
Collapse
|
23
|
An X, Chen L, Li J, Li KH. Compact integration of GaN-based photonic chip with microfluidics system. OPTICS LETTERS 2021; 46:170-173. [PMID: 33448980 DOI: 10.1364/ol.413215] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Accepted: 11/27/2020] [Indexed: 06/12/2023]
Abstract
This Letter reports a demonstration of integrating a tiny GaN-based photonic chip with a PDMS microfluidics system. The photonic chip containing InGaN/GaN quantum wells is responsible for light emission and photodetection and fabricated through standard microfabrication techniques. The PDMS-enclosed chip is formed adjacent to the fluidic channel and operates in reflection mode, enabling the optical signals coupled into and out of the fluidic channel without the aid of external optics. The luminescence and photo-detecting properties are thoroughly characterized, confirming that the chip is capable of tracking the continuously flowing microdroplets with the changes of absorbance, length, and flow rate. The novel, to the best of our knowledge, photonic integration presented in this Letter is a significant step forward in the development of compact, miniature, and self-contained on-chip sensing systems, which are of great value in portable lab-on-a-chip applications.
Collapse
|
24
|
High-throughput screening for high-efficiency small-molecule biosynthesis. Metab Eng 2020; 63:102-125. [PMID: 33017684 DOI: 10.1016/j.ymben.2020.09.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/31/2020] [Accepted: 09/01/2020] [Indexed: 01/14/2023]
Abstract
Systems metabolic engineering faces the formidable task of rewiring microbial metabolism to cost-effectively generate high-value molecules from a variety of inexpensive feedstocks for many different applications. Because these cellular systems are still too complex to model accurately, vast collections of engineered organism variants must be systematically created and evaluated through an enormous trial-and-error process in order to identify a manufacturing-ready strain. The high-throughput screening of strains to optimize their scalable manufacturing potential requires execution of many carefully controlled, parallel, miniature fermentations, followed by high-precision analysis of the resulting complex mixtures. This review discusses strategies for the design of high-throughput, small-scale fermentation models to predict improved strain performance at large commercial scale. Established and promising approaches from industrial and academic groups are presented for both cell culture and analysis, with primary focus on microplate- and microfluidics-based screening systems.
Collapse
|
25
|
Hengoju S, Tovar M, Man DKW, Buchheim S, Rosenbaum MA. Droplet Microfluidics for Microbial Biotechnology. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2020; 179:129-157. [PMID: 32888037 DOI: 10.1007/10_2020_140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Droplet microfluidics has recently evolved as a prominent platform for high-throughput experimentation for various research fields including microbiology. Key features of droplet microfluidics, like compartmentalization, miniaturization, and parallelization, have enabled many possibilities for microbiology including cultivation of microorganisms at a single-cell level, study of microbial interactions in a community, detection and analysis of microbial products, and screening of extensive microbial libraries with ultrahigh-throughput and minimal reagent consumptions. In this book chapter, we present several aspects and applications of droplet microfluidics for its implementation in various fields of microbial biotechnology. Recent advances in the cultivation of microorganisms in droplets including methods for isolation and domestication of rare microbes are reviewed. Similarly, a comparison of different detection and analysis techniques for microbial activities is summarized. Finally, several microbial applications are discussed with a focus on exploring new antimicrobials and high-throughput enzyme activity screening. We aim to highlight the advantages, limitations, and current developments in droplet microfluidics for microbial biotechnology while envisioning its enormous potential applications in the future.
Collapse
Affiliation(s)
- Sundar Hengoju
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology - Hans-Knöll-Institute (HKI), Jena, Germany.,Faculty of Biological Sciences, Friedrich Schiller University (FSU), Jena, Germany
| | - Miguel Tovar
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology - Hans-Knöll-Institute (HKI), Jena, Germany
| | - DeDe Kwun Wai Man
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology - Hans-Knöll-Institute (HKI), Jena, Germany
| | - Stefanie Buchheim
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology - Hans-Knöll-Institute (HKI), Jena, Germany.,Faculty of Biological Sciences, Friedrich Schiller University (FSU), Jena, Germany
| | - Miriam A Rosenbaum
- Bio Pilot Plant, Leibniz Institute for Natural Product Research and Infection Biology - Hans-Knöll-Institute (HKI), Jena, Germany. .,Faculty of Biological Sciences, Friedrich Schiller University (FSU), Jena, Germany.
| |
Collapse
|
26
|
Tang J, Qiu G, Cao X, Yue Y, Zhang X, Schmitt J, Wang J. Self-aligned 3D microlenses in a chip fabricated with two-photon stereolithography for highly sensitive absorbance measurement. LAB ON A CHIP 2020; 20:2334-2342. [PMID: 32458914 DOI: 10.1039/d0lc00235f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Absorbance measurement is a widely used method to quantify the concentration of an analyte. The integration of absorbance analysis in microfluidic chips could significantly reduce the sample consumption and contribute to the system miniaturization. However, the sensitivity and limit of detection (LoD) of analysis in microfluidic chips with conventional configuration need improvements due to the limited optical pathway and unregulated light propagation. In this work, a 3D-microlens-incorporating microfluidic chip (3D-MIMC) with a greatly extended detection channel was innovatively fabricated using two-photon stereolithography. The fabrication was optimized with a proposed hierarchical modular printing strategy. Due to the incorporation of 3D microlenses, the light coupling efficiency and the signal-to-noise ratio (SNR) were respectively improved approximately 9 and 4 times. An equivalent optical path length (EOL) of 62.9 mm was achieved in a 3.7 μl detection channel for testing tartrazine samples. As a result, the sensitivity and LoD of the 3D-MIMC assay were correspondingly improved by one order of magnitude, compared with those of the 96-well plate assay. Notably, the 3D-MIMC has the potential to be integrated into a general microanalysis platform for multiple applications.
Collapse
Affiliation(s)
- Jiukai Tang
- Institute of Environmental Engineering, ETH Zürich, Zürich 8093, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
27
|
Vasina M, Vanacek P, Damborsky J, Prokop Z. Exploration of enzyme diversity: High-throughput techniques for protein production and microscale biochemical characterization. Methods Enzymol 2020; 643:51-85. [PMID: 32896287 DOI: 10.1016/bs.mie.2020.05.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Enzymes are being increasingly utilized for acceleration of industrially and pharmaceutically critical chemical reactions. The strong demand for finding robust and efficient biocatalysts for these applications can be satisfied via the exploration of enzyme diversity. The first strategy is to mine the natural diversity, represented by millions of sequences available in the public genomic databases, by using computational approaches. Alternatively, metagenomic libraries can be targeted experimentally or computationally to explore the natural diversity of a specific environment. The second strategy, known as directed evolution, is to generate man-made diversity in the laboratory using gene mutagenesis and screen the constructed library of mutants. The selected hits must be experimentally characterized in both strategies, which currently represent the rate-limiting step in the process of diversity exploration. The traditional techniques used for biochemical characterization are time-demanding, cost, and sample volume ineffective, and low-throughput. Therefore, the development and implementation of high-throughput experimental methods are essential for discovering novel enzymes. This chapter describes the experimental protocols employing the combination of robust production and high-throughput microscale biochemical characterization of enzyme variants. We validated its applicability against the model enzyme family of haloalkane dehalogenases. These protocols can be adapted to other enzyme families, paving the way towards the functional characterization and quick identification of novel biocatalysts.
Collapse
Affiliation(s)
- Michal Vasina
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, Brno, Czech Republic; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
| | - Pavel Vanacek
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, Brno, Czech Republic; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
| | - Jiri Damborsky
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, Brno, Czech Republic; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic
| | - Zbynek Prokop
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, Brno, Czech Republic; International Clinical Research Center, St. Anne's University Hospital, Brno, Czech Republic.
| |
Collapse
|
28
|
“Development and application of analytical detection techniques for droplet-based microfluidics”-A review. Anal Chim Acta 2020; 1113:66-84. [DOI: 10.1016/j.aca.2020.03.011] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Revised: 03/02/2020] [Accepted: 03/05/2020] [Indexed: 01/03/2023]
|
29
|
Fohlerova Z, Zhu H, Hubalek J, Ni S, Yobas L, Podesva P, Otahal A, Neuzil P. Rapid Characterization of Biomolecules' Thermal Stability in a Segmented Flow-Through Optofluidic Microsystem. Sci Rep 2020; 10:6925. [PMID: 32332774 PMCID: PMC7181606 DOI: 10.1038/s41598-020-63620-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Accepted: 03/30/2020] [Indexed: 11/15/2022] Open
Abstract
Optofluidic devices combining optics and microfluidics have recently attracted attention for biomolecular analysis due to their high detection sensitivity. Here, we show a silicon chip with tubular microchannels buried inside the substrate featuring temperature gradient (∇T) along the microchannel. We set up an optical fluorescence system consisting of a power-modulated laser light source of 470 nm coupled to the microchannel serving as a light guide via optical fiber. Fluorescence was detected on the other side of the microchannel using a photomultiplier tube connected to an optical fiber via a fluorescein isothiocyanate filter. The PMT output was connected to a lock-in amplifier for signal processing. We performed a melting curve analysis of a short dsDNA - SYBR Green I complex with a known melting temperature (TM) in a flow-through configuration without gradient to verify the functionality of the proposed detection system. We then used the segmented flow configuration and measured the fluorescence amplitude of a droplet exposed to ∇T of ≈ 2.31 °C mm-1, determining the heat transfer time as ≈ 554 ms. The proposed platform can be used as a fast and cost-effective system for performing either MCA of dsDNAs or for measuring protein unfolding for drug-screening applications.
Collapse
Affiliation(s)
- Zdenka Fohlerova
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 3058/10, 61600, Brno, Czech Republic
| | - Hanliang Zhu
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, 710072, P.R. China
| | - Jaromir Hubalek
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 3058/10, 61600, Brno, Czech Republic
| | - Sheng Ni
- Hong Kong, University of Science and Technology, Clear Water Bay, Hong Kong, P.R. China
| | - Levent Yobas
- Hong Kong, University of Science and Technology, Clear Water Bay, Hong Kong, P.R. China
| | - Pavel Podesva
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic
| | - Alexandr Otahal
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 3058/10, 61600, Brno, Czech Republic
| | - Pavel Neuzil
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic.
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technicka 3058/10, 61600, Brno, Czech Republic.
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, 710072, P.R. China.
| |
Collapse
|
30
|
Hengoju S, Wohlfeil S, Munser AS, Boehme S, Beckert E, Shvydkiv O, Tovar M, Roth M, Rosenbaum MA. Optofluidic detection setup for multi-parametric analysis of microbiological samples in droplets. BIOMICROFLUIDICS 2020; 14:024109. [PMID: 32547676 PMCID: PMC7148121 DOI: 10.1063/1.5139603] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 03/27/2020] [Indexed: 05/03/2023]
Abstract
High-throughput microbiological experimentation using droplet microfluidics is limited due to the complexity and restricted versatility of the available detection techniques. Current detection setups are bulky, complicated, expensive, and require tedious optical alignment procedures while still mostly limited to fluorescence. In this work, we demonstrate an optofluidic detection setup for multi-parametric analyses of droplet samples by easily integrating micro-lenses and embedding optical fibers for guiding light in and out of the microfluidic chip. The optofluidic setup was validated for detection of absorbance, fluorescence, and scattered light. The developed platform was used for simultaneous detection of multiple parameters in different microbiological applications like cell density determination, growth kinetics, and antibiotic inhibition assays. Combining the high-throughput potential of droplet microfluidics with the ease, flexibility, and simplicity of optical fibers results in a powerful platform for microbiological experiments.
Collapse
Affiliation(s)
| | - S. Wohlfeil
- Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany
| | - A. S. Munser
- Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany
| | - S. Boehme
- Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany
| | - E. Beckert
- Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany
| | - O. Shvydkiv
- Leibniz Institute for Natural Product Research and Infection Biology, Hans Knoell Institute, Beutenbergstr. 11a, 07745 Jena, Germany
| | - M. Tovar
- Leibniz Institute for Natural Product Research and Infection Biology, Hans Knoell Institute, Beutenbergstr. 11a, 07745 Jena, Germany
| | - M. Roth
- Leibniz Institute for Natural Product Research and Infection Biology, Hans Knoell Institute, Beutenbergstr. 11a, 07745 Jena, Germany
| | | |
Collapse
|
31
|
Nightingale AM, Hassan SU, Makris K, Bhuiyan WT, Harvey TJ, Niu X. Easily fabricated monolithic fluoropolymer chips for sensitive long-term absorbance measurement in droplet microfluidics. RSC Adv 2020; 10:30975-30981. [PMID: 35516030 PMCID: PMC9056331 DOI: 10.1039/d0ra05330a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 07/21/2020] [Indexed: 12/16/2022] Open
Abstract
Maintaining a hydrophobic channel surface is critical to ensuring long-term stable flow in droplet microfluidics. Monolithic fluoropolymer chips ensure robust and reliable droplet flow as their native fluorous surfaces naturally preferentially wet fluorocarbon oils and do not deteriorate over time. Their fabrication, however, typically requires expensive heated hydraulic presses that make them inaccessible to many laboratories. Here we describe a method for micropatterning and bonding monolithic fluoropolymer flow cells from a commercially available melt-processable fluoropolymer, Dyneon THV 500GZ, that only requires a standard laboratory oven. Using this technique, we demonstrate the formation of complex microstructures, specifically the fabrication of sensitive absorbance flow cells for probing droplets in flow, featuring path lengths up to 10 mm. The native fluorous channel surface means the flow cells can be operated over extended periods, demonstrated by running droplets continuously through a chip for 16 weeks. We present a widely accessible method for fabricating monolithic fluoropolymer microfluidic chips, which allows droplet absorbance measurement over multi-month periods.![]()
Collapse
Affiliation(s)
- Adrian M. Nightingale
- Mechanical Engineering
- Faculty of Engineering and Physical Sciences
- University of Southampton
- Southampton
- UK
| | - Sammer-ul Hassan
- Mechanical Engineering
- Faculty of Engineering and Physical Sciences
- University of Southampton
- Southampton
- UK
| | - Kyriacos Makris
- SouthWestSensor Ltd
- Southampton Science Park
- The Innovation Centre
- Southampton
- UK
| | - Wahida T. Bhuiyan
- Mechanical Engineering
- Faculty of Engineering and Physical Sciences
- University of Southampton
- Southampton
- UK
| | - Terry J. Harvey
- Mechanical Engineering
- Faculty of Engineering and Physical Sciences
- University of Southampton
- Southampton
- UK
| | - Xize Niu
- Mechanical Engineering
- Faculty of Engineering and Physical Sciences
- University of Southampton
- Southampton
- UK
| |
Collapse
|
32
|
Droplet-based optofluidic systems for measuring enzyme kinetics. Anal Bioanal Chem 2019; 412:3265-3283. [PMID: 31853606 DOI: 10.1007/s00216-019-02294-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/15/2019] [Accepted: 11/19/2019] [Indexed: 01/05/2023]
Abstract
The study of enzyme kinetics is of high significance in understanding metabolic networks in living cells and using enzymes in industrial applications. To gain insight into the catalytic mechanisms of enzymes, it is necessary to screen an enormous number of reaction conditions, a process that is typically laborious, time-consuming, and costly when using conventional measurement techniques. In recent times, droplet-based microfluidic systems have proved themselves to be of great utility in large-scale biological experimentation, since they consume a minimal sample, operate at high analytical throughput, are characterized by efficient mass and heat transfer, and offer high levels of integration and automation. The primary goal of this review is the introduction of novel microfluidic tools and detection methods for use in high-throughput and sensitive analysis of enzyme kinetics. The first part of this review focuses on introducing basic concepts of enzyme kinetics and describing most common microfluidic approaches, with a particular focus on segmented flow. Herein, the key advantages include accurate control over the flow behavior, efficient mass and heat transfer, multiplexing, and high-level integration with detection modalities. The second part describes the current state-of-the-art platforms for high-throughput and sensitive analysis of enzyme kinetics. In addition to our categorization of recent advances in measuring enzyme kinetics, we have endeavored to critically assess the limitations of each of these detection approaches and propose strategies to improve measurements in droplet-based microfluidics. Graphical abstract.
Collapse
|
33
|
Nightingale AM, Hassan SU, Warren BM, Makris K, Evans GWH, Papadopoulou E, Coleman S, Niu X. A Droplet Microfluidic-Based Sensor for Simultaneous in Situ Monitoring of Nitrate and Nitrite in Natural Waters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:9677-9685. [PMID: 31352782 DOI: 10.1021/acs.est.9b01032] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Microfluidic-based chemical sensors take laboratory analytical protocols and miniaturize them into field-deployable systems for in situ monitoring of water chemistry. Here, we present a prototype nitrate/nitrite sensor based on droplet microfluidics that in contrast to standard (continuous phase) microfluidic sensors, treats water samples as discrete droplets contained within a flow of oil. The new sensor device can quantify the concentrations of nitrate and nitrite within each droplet and provides high measurement frequency and low fluid consumption. Reagent consumption is at a rate of 2.8 mL/day when measuring every ten seconds, orders of magnitude more efficient than those of the current state-of-the-art sensors. The sensor's capabilities were demonstrated during a three-week deployment in a tidal river. The accurate and high frequency data (6% error relative to spot samples, measuring at 0.1 Hz) elucidated the influence of tidal variation, rain events, diurnal effects, and anthropogenic input on concentrations at the deployment site. This droplet microfluidic-based sensor is suitable for a wide range of applications such as monitoring of rivers, lakes, coastal waters, and industrial effluents.
Collapse
Affiliation(s)
- Adrian M Nightingale
- Mechanical Engineering, Faculty of Engineering and Physical Sciences , University of Southampton , Southampton , SO17 1BJ , United Kingdom
| | - Sammer-Ul Hassan
- Mechanical Engineering, Faculty of Engineering and Physical Sciences , University of Southampton , Southampton , SO17 1BJ , United Kingdom
| | - Brett M Warren
- SouthWestSensor Ltd , Enterprise House, Ocean Village , Southampton , SO14 3XB , United Kingdom
| | - Kyriacos Makris
- SouthWestSensor Ltd , Enterprise House, Ocean Village , Southampton , SO14 3XB , United Kingdom
| | - Gareth W H Evans
- Mechanical Engineering, Faculty of Engineering and Physical Sciences , University of Southampton , Southampton , SO17 1BJ , United Kingdom
| | - Evanthia Papadopoulou
- SouthWestSensor Ltd , Enterprise House, Ocean Village , Southampton , SO14 3XB , United Kingdom
| | - Sharon Coleman
- Mechanical Engineering, Faculty of Engineering and Physical Sciences , University of Southampton , Southampton , SO17 1BJ , United Kingdom
- SouthWestSensor Ltd , Enterprise House, Ocean Village , Southampton , SO14 3XB , United Kingdom
| | - Xize Niu
- Mechanical Engineering, Faculty of Engineering and Physical Sciences , University of Southampton , Southampton , SO17 1BJ , United Kingdom
- SouthWestSensor Ltd , Enterprise House, Ocean Village , Southampton , SO14 3XB , United Kingdom
| |
Collapse
|
34
|
Buryska T, Vasina M, Gielen F, Vanacek P, van Vliet L, Jezek J, Pilat Z, Zemanek P, Damborsky J, Hollfelder F, Prokop Z. Controlled Oil/Water Partitioning of Hydrophobic Substrates Extending the Bioanalytical Applications of Droplet-Based Microfluidics. Anal Chem 2019; 91:10008-10015. [PMID: 31240908 DOI: 10.1021/acs.analchem.9b01839] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Functional annotation of novel proteins lags behind the number of sequences discovered by the next-generation sequencing. The throughput of conventional testing methods is far too low compared to sequencing; thus, experimental alternatives are needed. Microfluidics offer high throughput and reduced sample consumption as a tool to keep up with a sequence-based exploration of protein diversity. The most promising droplet-based systems have a significant limitation: leakage of hydrophobic compounds from water compartments to the carrier prevents their use with hydrophilic reagents. Here, we present a novel approach of substrate delivery into microfluidic droplets and apply it to high-throughput functional characterization of enzymes that convert hydrophobic substrates. Substrate delivery is based on the partitioning of hydrophobic chemicals between the oil and water phases. We applied a controlled distribution of 27 hydrophobic haloalkanes from oil to reaction water droplets to perform substrate specificity screening of eight model enzymes from the haloalkane dehalogenase family. This droplet-on-demand microfluidic system reduces the reaction volume 65 000-times and increases the analysis speed almost 100-fold compared to the classical test tube assay. Additionally, the microfluidic setup enables a convenient analysis of dependences of activity on the temperature in a range of 5 to 90 °C for a set of mesophilic and hyperstable enzyme variants. A high correlation between the microfluidic and test tube data supports the approach robustness. The precision is coupled to a considerable throughput of >20 000 reactions per day and will be especially useful for extending the scope of microfluidic applications for high-throughput analysis of reactions including compounds with limited water solubility.
Collapse
Affiliation(s)
- Tomas Buryska
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science , Masaryk University , Kamenice 5 , Brno 625 00 , Czech Republic.,International Clinical Research Center , St. Anne's University Hospital , Pekarska 53 , Brno 656 91 , Czech Republic
| | - Michal Vasina
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science , Masaryk University , Kamenice 5 , Brno 625 00 , Czech Republic.,International Clinical Research Center , St. Anne's University Hospital , Pekarska 53 , Brno 656 91 , Czech Republic
| | - Fabrice Gielen
- Department of Biochemistry , University of Cambridge , 80 Tennis Court Road , Cambridge CB2 1GA , United Kingdom.,Living Systems Institute , University of Exeter , Exeter EX4 4QD , United Kingdom
| | - Pavel Vanacek
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science , Masaryk University , Kamenice 5 , Brno 625 00 , Czech Republic.,International Clinical Research Center , St. Anne's University Hospital , Pekarska 53 , Brno 656 91 , Czech Republic
| | - Liisa van Vliet
- Department of Biochemistry , University of Cambridge , 80 Tennis Court Road , Cambridge CB2 1GA , United Kingdom
| | - Jan Jezek
- Institute of Scientific Instruments, Czech Academy of Sciences , Kralovopolska 147 , Brno 612 64 , Czech Republic
| | - Zdenek Pilat
- Institute of Scientific Instruments, Czech Academy of Sciences , Kralovopolska 147 , Brno 612 64 , Czech Republic
| | - Pavel Zemanek
- Institute of Scientific Instruments, Czech Academy of Sciences , Kralovopolska 147 , Brno 612 64 , Czech Republic
| | - Jiri Damborsky
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science , Masaryk University , Kamenice 5 , Brno 625 00 , Czech Republic.,International Clinical Research Center , St. Anne's University Hospital , Pekarska 53 , Brno 656 91 , Czech Republic
| | - Florian Hollfelder
- Department of Biochemistry , University of Cambridge , 80 Tennis Court Road , Cambridge CB2 1GA , United Kingdom
| | - Zbynek Prokop
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science , Masaryk University , Kamenice 5 , Brno 625 00 , Czech Republic.,International Clinical Research Center , St. Anne's University Hospital , Pekarska 53 , Brno 656 91 , Czech Republic
| |
Collapse
|
35
|
Lombardo T, Lancellotti L, Souprayen C, Sella C, Thouin L. Electrochemical Detection of Droplets in Microfluidic Devices: Simultaneous Determination of Velocity, Size and Content. ELECTROANAL 2019. [DOI: 10.1002/elan.201900293] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Teo Lombardo
- Département de chimie, Ecole normale supérieureUniversité PSL, Sorbonne Université, CNRS 75005 Paris France
| | - Lidia Lancellotti
- Département de chimie, Ecole normale supérieureUniversité PSL, Sorbonne Université, CNRS 75005 Paris France
| | - Christelle Souprayen
- Département de chimie, Ecole normale supérieureUniversité PSL, Sorbonne Université, CNRS 75005 Paris France
| | - Catherine Sella
- Département de chimie, Ecole normale supérieureUniversité PSL, Sorbonne Université, CNRS 75005 Paris France
| | - Laurent Thouin
- Département de chimie, Ecole normale supérieureUniversité PSL, Sorbonne Université, CNRS 75005 Paris France
| |
Collapse
|
36
|
A Low-Cost Time-Correlated Single Photon Counting Portable DNA Analyzer. SENSORS 2019; 19:s19132838. [PMID: 31247893 PMCID: PMC6651547 DOI: 10.3390/s19132838] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Revised: 06/21/2019] [Accepted: 06/24/2019] [Indexed: 12/29/2022]
Abstract
Photon-counting analysis of nucleic acids plays a key role in many diagnostics applications for its accurate and non-invasive nature. However, conventional photon-counting instrumentations are bulky and expensive due to the use of conventional optics and a lack of optimization of electronics. In this paper, we present a portable, low-cost time-correlated single photon-counting (TCSPC) analysis system for DNA detection. Both optical and electronic subsystems are carefully designed to provide effective emission filtering and size reduction, delivering good DNA detection and fluorescence lifetime extraction performance. DNA detection has been verified by fluorescence lifetime measurements of a V-carbazole conjugated fluorophore lifetime bioassay. The time-to-digital module of the proposed TCSPC system achieves a full width at half maximum (FWHM) timing resolution from 121 to 145 ps and a differential non-linearity (DNL) between −8.5% and +9.7% of the least significant bit (LSB) within the 500 ns full-scale range (FSR). With a detection limit of 6.25 nM and a dynamic range of 6.8 ns, the proposed TCSPC system demonstrates the enabling technology for rapid, point-of-care DNA diagnostics.
Collapse
|
37
|
Wei L, Tian Y, Yan W, Cheung K, Ho D. Liquid-core waveguide TCSPC sensor for high-accuracy fluorescence lifetime analysis. Anal Bioanal Chem 2019; 411:3641-3652. [PMID: 31037372 DOI: 10.1007/s00216-019-01847-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 03/14/2019] [Accepted: 04/12/2019] [Indexed: 10/26/2022]
Abstract
Liquid-core waveguide (LCW) has many advantages such as the elimination of optical artifacts typically exhibited in systems employing lenses and filters. However, due to the effect of temporal dispersion, LCWs are typically employed in steady-state fluorescence detection microsystems rather than in fluorescence lifetime measurement (FLM) systems. In this paper, we present a compact liquid-core waveguide time-correlated single-photon counting (LCW-TCSPC) sensor for FLM. The propagation of excitation within the LCW is analyzed both analytically and in simulations, with results in agreement with experimental characterization. Results reveal an optimal region within the LCW for highly accurate FLM. The proposed prototype achieves excellent excitation rejection and low temporal dispersion as a result of optimization of the propagation length of the excitation within the LCW. The prototype achieves a detection limit of 5 nM for Coumarin 6 in dimethyl sulfoxide with < 3% lifetime error. The techniques proposed for analyzing the LCW for TCSPC based FLM and prototype demonstration pave the way for developing high-performance fluorescence lifetime measurement for microfluidics and point-of-care applications. Graphical abstract A compact liquid-core waveguide time-correlated single-photon counting (LCW-TCSPC) sensor for fluorescence lifetime measurement (FLM) is presented. Results reveal an optimal propagation length region within the LCW for highly accurate FLM. The prototype achieves a detection limit of 5 nM for Coumarin 6 in dimethyl sulfoxide with < 3% lifetime error.
Collapse
Affiliation(s)
- Liping Wei
- Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
| | - Yi Tian
- Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
| | - Wenrong Yan
- Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
| | - Kawai Cheung
- Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong
| | - Derek Ho
- Department of Materials Science and Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong.
| |
Collapse
|