1
|
Yu Y, Jiang J, Hua L, Li X, Li H. Pressure-Driven Switching of Photoelectron Impact Ionization-Chemical Ionization/Penning Ionization in Vacuum Ultraviolet Photoionization Mass Spectrometry. Anal Chem 2024; 96:5686-5693. [PMID: 38551337 DOI: 10.1021/acs.analchem.4c00686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
Vacuum ultraviolet photoionization (VUV-PI) is a soft ionization technique that operates under pressures ranging from vacuum to ambient pressure. VUV-PI has played an essential role in direct sampling mass spectrometry. In this study, new ionization processes initiated by photoelectrons have been studied through the inclusion of a radio frequency (RF) electric field at different pressures. After deducting the contribution of single photoionization (SPI), the signal intensity of 1 ppmv toluene (C7H8+) in Ar was approximately 5-fold higher than that in N2. Mixed gases with different ionization energies (IEs) and excitation energies (EEs) were further investigated to reveal that metastable species were involved in the enhancement process. Reactant ions were produced by photoelectron impact ionization (PEI), which further triggered ion-molecule reactions, i.e., chemical ionization (CI). Metastable species were produced by photoelectron impact excitation (PEE), which further triggered Penning ionization (PenI). Analytes with IEs above 10.6 eV, such as CO2 (IE = 13.78 eV) and CHCl3 (IE = 11.37 eV), could be sensitively ionized by PenI with a sensitivity comparable to SPI. Except for the contribution of SPI, the dominant ionization process was switched from PEI-CI to PenI when the pressure was elevated from 50 to 500 Pa, as the electron energy gradually decreased and was only able to produce metastable states based on the kinetic energy balance equation of electrons. The conversion processes and conditions from PEI-CI to PenI will provide novel insights to develop new selective and sensitive VUV-PI sources and understand the ionization mechanism in other discharge ionization sources.
Collapse
Affiliation(s)
- Yi Yu
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China
- Dalian Key Laboratory for Online Analytical Instrumentation, Dalian 116023, People's Republic of China
| | - Jichun Jiang
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China
- Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China
- Dalian Key Laboratory for Online Analytical Instrumentation, Dalian 116023, People's Republic of China
| | - Lei Hua
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China
- Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China
- Dalian Key Laboratory for Online Analytical Instrumentation, Dalian 116023, People's Republic of China
| | - Xinyang Li
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China
- Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China
- Dalian Key Laboratory for Online Analytical Instrumentation, Dalian 116023, People's Republic of China
| | - Haiyang Li
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China
- Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian 116023, People's Republic of China
- Dalian Key Laboratory for Online Analytical Instrumentation, Dalian 116023, People's Republic of China
| |
Collapse
|
2
|
Bouza M, García-Martínez J, Gilbert-López B, Brandt S, García-Reyes JF, Molina-Díaz A, Franzke J. Dielectric Barrier Discharge Ionization Mechanisms: Polycyclic Aromatic Hydrocarbons as a Case of Study. Anal Chem 2022; 95:854-861. [PMID: 36538370 PMCID: PMC9850405 DOI: 10.1021/acs.analchem.2c03279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Dielectric barrier discharge ionization (DBDI) is a versatile tool for small-molecule mass spectrometry applications, helping cover from polar to low polar molecules. However, the plasma gas-phase interactions are highly complex and have been scarcely investigated. The ionization mechanisms of plasmas have long been assumed to be somewhat similar to atmospheric pressure chemical ionization (APCI). Here, we evaluated the ionization mechanisms of a two-ring DBDI ion source, using different discharge gases to analyze vaporized liquid samples. Polycyclic aromatic hydrocarbons (PAHs) were used as model analytes to assess the mechanisms' dominance: protonation, [M + H]+, or radical ion species formation, [M]·+. In the present work, two different ionization trends were observed for APCI and DBDI during the PAH analysis; the compounds with proton affinities (PA) over 856 kJ/mol were detected as [M + H]+ when APCI was used as ionization source. Meanwhile, independently of the PA, DBDI showed the prevalence of charge exchange reactions. The addition of dopants in the gas-phase region shifted the ionization mechanisms toward charge exchange reactions, facilitating the formation of [M]·+ ion species, showing anisole a significant boost of the PAH radical ion species signals, over nine times for Ar-Prop-DBDI analysis. The presence of high-energy metastable atoms (e.g., HeM) with high ionization potentials (IE = 19.80 eV) did not show boosted PAH abundances or extensive molecule fragmentation. Moreover, other species in the plasma jet region with closer and more appropriate IE, such as N2 B3Πg excited molecules, are likely responsible for PAH Penning ionization.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain,. Phone: +34 953 212758
| | - Julio García-Martínez
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Bienvenida Gilbert-López
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Sebastian Brandt
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139Dortmund, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Antonio Molina-Díaz
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071Jaén, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139Dortmund, Germany,. Phone: +49 0231 1392-174
| |
Collapse
|
3
|
Bouza M, García-Martínez J, Gilbert-López B, Moreno-González D, Rocío-Bautista P, Parras-Guijarro D, Sánchez-Vizcaino A, Brandt S, García-Reyes JF, Molina-Díaz A, Franzke J. Liquid Chromatography-Dielectric Barrier Discharge Ionization Mass Spectrometry for the analysis of neutral lipids of archaeological interest. J Sep Sci 2022; 45:3105-3114. [PMID: 35801641 PMCID: PMC9544991 DOI: 10.1002/jssc.202200402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 07/05/2022] [Accepted: 07/05/2022] [Indexed: 11/15/2022]
Abstract
Dielectric barrier discharge ionization has gained attention in the last few years due to its versatility and the vast array of molecules that can be ionized. In this study, we report on the assessment of liquid chromatography coupled to dielectric barrier discharge ionization with mass spectrometry for neutral lipid analysis. A set of different neutral lipid subclasses (triacylglycerides, diacylglycerides, and sterols) were selected for the study. The main species detected from our ionization source were [M‐H2O+H]+, [M+H]+ or [M‐R‐H2O+H]+, attributed to sterol dehydration, protonation or the fragmentation of an acyl chain accompanied by a water loss of the glycerolipids, respectively. In terms of sensitivity, the dielectric barrier discharge displayed overall improved abundances and comparable or better limits of quantitation than atmospheric pressure chemical ionization for both acylglycerols and sterols. As a case study, different archaeological samples with variable content in neutral lipids, particularly triacylglycerides, were studied. The identification was carried out by combining accurate mass and the tentative formula associated with the exact mass, retention time matching with standards, and additional structural information from in‐source fragmentation. The high degree of unsaturation and the presence of sterols revealed the potential vegetal origin of the material stored in the analyzed samples.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Julio García-Martínez
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain.,University Research Institute for Olives Grove and Olive Oil, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - David Moreno-González
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Priscilla Rocío-Bautista
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - David Parras-Guijarro
- University Research Institute for Iberian Archaeology, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Alberto Sánchez-Vizcaino
- University Research Institute for Iberian Archaeology, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Sebastian Brandt
- ISAS-Leibniz Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139, Dortmund, Germany
| | - Juan F García-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain.,University Research Institute for Olives Grove and Olive Oil, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain.,University Research Institute for Iberian Archaeology, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Antonio Molina-Díaz
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain.,University Research Institute for Olives Grove and Olive Oil, University of Jaén, Campus Las Lagunillas, Jaén, 23071, Spain
| | - Joachim Franzke
- ISAS-Leibniz Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139, Dortmund, Germany
| |
Collapse
|
4
|
Guo X, Pu J, Dai J, Zhao Z, Duan Y. Elucidation of formation mechanism responsible for charge-transfer reagent ions in microwave induced plasma desorption ionization (MIPDI) source. Talanta 2022; 250:123656. [DOI: 10.1016/j.talanta.2022.123656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/30/2022] [Accepted: 06/03/2022] [Indexed: 11/29/2022]
|
5
|
Li D, Li Z, Xu B, Chen J, Xue J, Hu S, Wen L, Guo L, Xie J, Jiang G. Thermal desorption bridged the gap between dielectric barrier discharge ionization and dried plasma spot samples for sensitive and rapid detection of fentanyl analogs in mass spectrometry. Analyst 2022; 147:4187-4196. [DOI: 10.1039/d2an00946c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Guided by finite element simulations and 3D-printing, we constructed a semi-covered flat-TD surface for sufficient thermal desorption and ionization of fentanyl analogs from dried plasma/blood spot samples.
Collapse
Affiliation(s)
- Dongmei Li
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- National Anti-Drug Laboratory Beijing Regional Center, Beijing 100164, China
| | - Zehua Li
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Bin Xu
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Jia Chen
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Jinjuan Xue
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Shundi Hu
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo 315211, China
| | - Luhong Wen
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo 315211, China
| | - Lei Guo
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Jianwei Xie
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Beijing 100850, China
| | - Guibin Jiang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| |
Collapse
|
6
|
Molnar BT, Shelley JT. MODERN PLASMA-BASED DESORPTION/IONIZATION: FROM ATOMS AND MOLECULES TO CHEMICAL SYNTHESIS. MASS SPECTROMETRY REVIEWS 2021; 40:609-627. [PMID: 32770688 DOI: 10.1002/mas.21645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 02/05/2020] [Accepted: 07/07/2020] [Indexed: 06/11/2023]
Abstract
Since the first mass spectrometry (MS) experiments were conducted by Thomson and Aston, plasmas have been used as ionization sources. Historically, plasma ion sources were used for these experiments because they were one of the few known sources of gas-phase ions at the time and they were relatively simple to setup and operate. Since then, developments in plasma ionization have continued to inform and motivate advances in other areas of MS. For example, plasma-desorption MS demonstrated ionization of large peptides and polymers more than 10 years before the first descriptions of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI). As a result, significant effort was placed on development of ionization approaches, mass analysis, and detection approaches for very large molecules: even before the advent of ESI and MALDI. Since then, new analytical challenges and opportunities in plasma ionization have arisen. In this review, the emerging trends in plasma-based ionization for several areas of MS will be discussed, including molecular ionization, elemental ionization, hybrid elemental and molecular ion sources, and unique chemical transformations. © 2020 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Brian T Molnar
- Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180
| | - Jacob T Shelley
- Department of Chemistry and Chemical Biology, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180
| |
Collapse
|
7
|
Brecht D, Uteschil F, Schmitz OJ. Development of an inverse low-temperature plasma ionization source for liquid chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9071. [PMID: 33625792 DOI: 10.1002/rcm.9071] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 02/17/2021] [Accepted: 02/19/2021] [Indexed: 06/12/2023]
Abstract
RATIONALE An argon inverse low-temperature plasma (iLTP) ionization source for liquid chromatography/tandem mass spectrometry was developed. The iLTP is constructed from simple chromatographic supply materials and is implemented into an atmospheric pressure chemical ionization (APCI) source replacing the APCI discharge needle electrode. The newly developed ion source was coupled to an ultra-high-performance liquid chromatography (UHPLC) system. METHODS The argon iLTP was characterized by optical emission spectroscopy. The soft ionization of selected standards was also demonstrated by direct infusion experiments. In addition to the use of argon as the discharge gas, helium, synthetic air, and oxygen were used, which were tested for their performance using testosterone and vitamin D3 . RESULTS Spectroscopic measurements of the argon plasma were conducted, demonstrating the main emission band of argon metastables with corresponding energies of 11.53 eV and 11.72 eV. Infusion experiments indicate a gentle ionization by iLTP, e.g. caffeine, testosterone, reserpine, vitamin D3 , and 25-hydroxyvitamin D3 , which resulted in the corresponding protonated molecules. The splitless coupling with UHPLC (possible flow rates >1000 μL min-1 ) shows promising results in interday repeatability (n = 10) for the substances with a relative standard deviation of less than 5% and limits of detection for caffeine, testosterone, reserpine, vitamin D3 , and 25-hydroxyvitamin D3 of 10 ng L-1 , 50 ng L-1 , 500 ng L-1 , 5 μg L-1 , and 5 μg L-1 , respectively. CONCLUSIONS The argon iLTP ion source presented in this work shows promising approaches in the field of ionization of small organic molecules. The mechanism related to the discharge gas argon has not been elucidated so far and further investigations are needed. The iLTP ion source shows a very good performance with UHPLC coupling, even at increased flow rates. It could be shown that an argon iLTP can compete with the helium dielectric barrier discharge (DBD) preferred in the literature, making it a more economical choice.
Collapse
Affiliation(s)
- Dominik Brecht
- Department of Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen, 45141, Germany
| | - Florian Uteschil
- Department of Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen, 45141, Germany
| | - Oliver J Schmitz
- Department of Applied Analytical Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen, 45141, Germany
| |
Collapse
|
8
|
Review: Miniature dielectric barrier discharge (DBD) in analytical atomic spectrometry. Anal Chim Acta 2021; 1147:211-239. [DOI: 10.1016/j.aca.2020.11.034] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 11/17/2020] [Accepted: 11/22/2020] [Indexed: 11/24/2022]
|
9
|
Drees C, Schütz A, Niu G, Franzke J, Vautz W, Brandt S. Stepwise optimization of a Flexible Microtube Plasma (FµTP) as an ionization source for Ion Mobility Spectrometry. Anal Chim Acta 2020; 1127:89-97. [PMID: 32800141 DOI: 10.1016/j.aca.2020.06.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 06/05/2020] [Accepted: 06/09/2020] [Indexed: 11/24/2022]
Abstract
The ionization source is the central system of analytical devices such as mass spectrometers or ion mobility spectrometers. In this study, a recently developed flexible microtube plasma (FμTP) is applied as an ionization source for a custom-made drift tube ion mobility spectrometer (IMS) for the first time. The FµTP is based on a highly miniaturized, robust and a small-footprint dielectric barrier discharge design with an outstanding ionization efficiency. In this study, the experimental setup of the FµTP was further improved upon to achieve optimal coupling conditions in terms of the ion mobility spectrometry sensitivity and the plasma gas consumption. One major focus of this study was the adjustment of the electrical operation parameters, in particular, the high voltage amplitude, frequency and duty cycle, in order to minimize the electric field disturbances and yield higher signals. Additionally, the consumption of helium plasma gas was reduced by refining the FµTP. It was found that the ionization efficiency could be significantly enhanced by increasing the plasma high voltage and through application of a duty cycle up to 90:10. Plasma gas flows could be reduced down to 3 mL min-1 by increasing the plasma high voltage amplitude. Furthermore, a smaller wire electrode design enables the operation of the FµTP with nitrogen and clean air. Moreover, detection limits of a homologous series of ketones in the range of 330 pptv (N2-FµTP, 2-decanone) down to 20 pptv (He-FµTP, 2-octanone) could be reached in the optimized setup. To sum up, this feasibility study demonstrates the potential of the optimized FµTP as a powerful ionization source for ion mobility spectrometry especially with regard to ionization efficiency.
Collapse
Affiliation(s)
- Carolin Drees
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139, Dortmund, Germany
| | - Alexander Schütz
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139, Dortmund, Germany
| | - Guanghui Niu
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139, Dortmund, Germany
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139, Dortmund, Germany
| | - Wolfgang Vautz
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139, Dortmund, Germany; ION-GAS GmbH, Konrad-Adenauer-Allee 11, 44263, Dortmund, Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139, Dortmund, Germany.
| |
Collapse
|
10
|
Vogel P, Lazarou C, Gazeli O, Brandt S, Franzke J, Moreno-González D. Study of Controlled Atmosphere Flexible Microtube Plasma Soft Ionization Mass Spectrometry for Detection of Volatile Organic Compounds as Potential Biomarkers in Saliva for Cancer. Anal Chem 2020; 92:9722-9729. [PMID: 32579344 DOI: 10.1021/acs.analchem.0c01063] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
A new soft ionization device for mass spectrometry is presented using the flexible microtube plasma under controlled atmospheric conditions. The controlled atmosphere flexible microtube plasma consists of the plasma source itself connected to a gas chromatograph and a mass spectrometer using a borosilicate glass cross piece. Controlled atmosphere, for example, nitrogen and/or an oxygen mixture, is introduced to the system to create a clean ionization environment. Reproducibility issues are discussed, and solutions are presented manipulating the gas flow in the cross piece. A proof of concept is shown using a ketone mixture introduced to the mass spectrometer to optimize atmospheric conditions. Furthermore, application of the presented device for the sensitive and nonfragmenting ionization of volatile organic biomarkers relevant for cancer is carried out. Sample treatment for human saliva is described, and relevant candidate biomarkers are measured in the saliva matrix, showing a very good ionization efficiency and neglectable matrix effects with limits of detection below 80 ppt.
Collapse
Affiliation(s)
- Pascal Vogel
- ISAS-Leibniz-Institut für Analytische Wissenschaften, Bunsen Kirchhoff Strasse 11, Dortmund 44139, Germany
| | - Constantinos Lazarou
- FOSS Research Centre for Sustainable Energy, PV Technology, University of Cyprus, 75 Kallipoleos Street, Nicosia 1678, Cyprus
| | - Odhisea Gazeli
- FOSS Research Centre for Sustainable Energy, PV Technology, University of Cyprus, 75 Kallipoleos Street, Nicosia 1678, Cyprus
| | - Sebastian Brandt
- ISAS-Leibniz-Institut für Analytische Wissenschaften, Bunsen Kirchhoff Strasse 11, Dortmund 44139, Germany
| | - Joachim Franzke
- ISAS-Leibniz-Institut für Analytische Wissenschaften, Bunsen Kirchhoff Strasse 11, Dortmund 44139, Germany
| | - David Moreno-González
- ISAS-Leibniz-Institut für Analytische Wissenschaften, Bunsen Kirchhoff Strasse 11, Dortmund 44139, Germany
| |
Collapse
|
11
|
Pu J, Dai J, He F, Zhu S, Zhao Z, Duan Y. Interpretation of Ionization Mechanism Responsible for Reagent Ion and Analyte Formation in Microwave-Induced Plasma Desorption Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:752-762. [PMID: 32003981 DOI: 10.1021/jasms.0c00027] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Ambient desorption/ionization (ADI) sources coupled to mass spectrometer have gained increasing interest in the field of analytical chemistry for its fast and direct analysis of samples. Among many ADI sources, plasma-based ADI sources are an important branch. Despite its extensive use in mass spectrometry analysis, the ionization mechanism of these sources still remain uncertain. The study on ionization mechanism is of great significance to optimize the design of ion sources and to improve ionization efficiency. In this study, targeted research on a better understanding of afterglow distance effects on ionization process was conducted. Based on the quantified signal expression of reagent ions in mass spectrum, the concept that optimal atmospheric analysis distance of plasma ADI source is defined for the first time. From the perspective of mutual restriction effect between atmospheric components, the formation progress of reagent ions was visually revealed in detail, which involved the initial step of forming precursor reagent ions, the clusters reaction for increasing production of reagent ions, and the matrix effect results in reagent ion depletion. The formation mechanism of reagent ions further clarified the explicit reason for abundant reagent ions generated at an optimal distance. Most importantly, the analyte analysis results verified the significant impact of appropriate distance on ionization efficiency in afterglow region. It was confirmed that the quantity and type of reagent ions intimately influenced the status of analyte ions in mass spectrum.
Collapse
Affiliation(s)
| | - Jianxiong Dai
- College of Chemistry and Material Science, Northwest University, Xi'an 710069, P.R. China
| | | | | | | | | |
Collapse
|
12
|
Pavlov J, Douce D, Bajic S, Attygalle AB. 1,4-Benzoquinone as a Highly Efficient Dopant for Enhanced Ionization and Detection of Nitramine Explosives on a Single-Quadrupole Mass Spectrometer Fitted with a Helium-Plasma Ionization (HePI) Source. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2704-2710. [PMID: 31673948 DOI: 10.1007/s13361-019-02339-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 09/04/2019] [Accepted: 09/09/2019] [Indexed: 06/10/2023]
Abstract
Previous investigations have evaluated the efficacy of anions such as NO3-, Cl-, Br-, CH3COO-, and CF3COO- as additives to generate or enhance mass spectrometric signals from explosives under plasma ionization conditions. The results of this study demonstrate that for detecting nitramine-class explosives, such as 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) and 1,3,5,7-tetranitro-1,3,5,7-tetrazacyclooctane (HMX), 1,4-benzoquinone (BQ) is a highly effective and efficient dopant. When used in conjunction with ambient-pressure negative-ion helium-plasma ionization (HePI), 1,4-benzoquinone readily captures an electron, forming an abundant molecular anion (m/z 108), which upon exposure to vapors of RDX and HMX generates adduct ions of m/z 330 and 404, respectively. The signal level recorded for RDX upon adduction to the radical anion of 1,4-benzoquinone under our experimental conditions was significantly higher than that realized by chloride adduction using dichloromethane (DCM) as the dopant.
Collapse
Affiliation(s)
- Julius Pavlov
- Center for Mass Spectrometry, Department of Chemistry and Chemical Biology, Stevens Institute of Technology, Hoboken, NJ, 07030, USA
| | | | | | - Athula B Attygalle
- Center for Mass Spectrometry, Department of Chemistry and Chemical Biology, Stevens Institute of Technology, Hoboken, NJ, 07030, USA.
| |
Collapse
|
13
|
A Critical Review of Recent Progress and Perspective in Practical Denitration Application. Catalysts 2019. [DOI: 10.3390/catal9090771] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Nitrogen oxides (NOx) represent one of the main sources of haze and pollution of the atmosphere as well as the causes of photochemical smog and acid rain. Furthermore, it poses a serious threat to human health. With the increasing emission of NOx, it is urgent to control NOx. According to the different mechanisms of NOx removal methods, this paper elaborated on the adsorption method represented by activated carbon adsorption, analyzed the oxidation method represented by Fenton oxidation, discussed the reduction method represented by selective catalytic reduction, and summarized the plasma method represented by plasma-modified catalyst to remove NOx. At the same time, the current research status and existing problems of different NOx removal technologies were revealed and the future development prospects were forecasted.
Collapse
|
14
|
Vogel P, Marggraf U, Brandt S, García-Reyes JF, Franzke J. Analyte-Tailored Controlled Atmosphere Improves Dielectric Barrier Discharge Ionization Mass Spectrometry Performance. Anal Chem 2019; 91:3733-3739. [PMID: 30672695 DOI: 10.1021/acs.analchem.9b00112] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Plasma sources in atmospheric pressure soft-ionization mass spectrometry have gained significant interest in recent years. As many of these sources are used under ambient air conditions, their interaction with the surrounding atmosphere plays an important role in the ionization pathway. This study focuses on the interaction between the plasma source and the surrounding atmosphere by connecting the plasma source to the mass spectrometer using a 2 mm ID closed reactant capillary supplied by a reactant gas up to 500 mL per minute to gain a controlled atmosphere. Different reactant gases (Ar, He, O2, and N2) and reactant gas mixtures are tested with regard to the DBDI performance and then used to improve the ionization efficiency. Tailoring the controlled atmosphere for a certain analyte, for example, perfluorinated compounds, leads to significantly improved limits of detection up to 2 ppb.
Collapse
Affiliation(s)
- Pascal Vogel
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V. , Bunsen-Kirchhoff-Straße 11 , 44139 Dortmund , Germany
| | - Ulrich Marggraf
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V. , Bunsen-Kirchhoff-Straße 11 , 44139 Dortmund , Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V. , Bunsen-Kirchhoff-Straße 11 , 44139 Dortmund , Germany
| | - Juan F García-Reyes
- Analytical Chemistry Research Group , University of Jaén , Campus Las Lagunillas , 23071 Jaén , Spain
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V. , Bunsen-Kirchhoff-Straße 11 , 44139 Dortmund , Germany
| |
Collapse
|
15
|
Wang Y, Sun J, Qiao J, Ouyang J, Na N. A "Soft" and "Hard" Ionization Method for Comprehensive Studies of Molecules. Anal Chem 2018; 90:14095-14099. [PMID: 30422630 DOI: 10.1021/acs.analchem.8b04437] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Ambient mass spectrometry can be rapidly and directly effective for molecular studies, while there still seems to be a gap between two major groups of electrospray ionization (ESI)- and atmospheric pressure chemical ionization (APCI)-related techniques, for detection of moderately polar to polar and low polar to nonpolar molecules in a relatively low mass range, respectively. Here, an extensively applicable "soft" and "hard" ionization method, spray-dependent plasma mass spectrometry (SDP MS), was established for detecting various molecules with diverse polarities or molecular weights. By SDP MS, both fragment ions and intact molecular ions can be obtained. Significantly, cluster ions of aggregates in high mass range formed by weak molecular interactions can also be well recorded, much softer than traditional ESI MS. By filling the gap between ESI-based and APCI-based ionization techniques, SDP MS would enhance MS performance for comprehensive molecular studies and be extensively applicable in fields of organic synthesis, biological chemistry, medical chemistry, and clinical diagnosis.
Collapse
Affiliation(s)
- Yan Wang
- Key Laboratory of Theoretical and Computational Photochemistry, College of Chemistry , Beijing Normal University , Beijing 100875 , China
| | - Jianghui Sun
- Key Laboratory of Theoretical and Computational Photochemistry, College of Chemistry , Beijing Normal University , Beijing 100875 , China
| | - Jinping Qiao
- Key Laboratory of Theoretical and Computational Photochemistry, College of Chemistry , Beijing Normal University , Beijing 100875 , China
| | - Jin Ouyang
- Key Laboratory of Theoretical and Computational Photochemistry, College of Chemistry , Beijing Normal University , Beijing 100875 , China
| | - Na Na
- Key Laboratory of Theoretical and Computational Photochemistry, College of Chemistry , Beijing Normal University , Beijing 100875 , China
| |
Collapse
|
16
|
Brandt S, Klute FD, Schütz A, Marggraf U, Drees C, Vogel P, Vautz W, Franzke J. Flexible Microtube Plasma (FμTP) as an Embedded Ionization Source for a Microchip Mass Spectrometer Interface. Anal Chem 2018; 90:10111-10116. [PMID: 30063325 DOI: 10.1021/acs.analchem.8b01493] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Dielectric barrier discharges are used as soft ionization sources for mass spectrometers or ion mobility spectrometers, enabling excellent possibilities for analytical applications. A new robust and small-footprint discharge design, flexible microtube plasma (FμTP), developed as a result of ongoing miniaturization and electrode design processes, is presented in this work. This design provides major safety benefits by fitting the electrode into an inert flexible fused silica capillary (tube). Notably, in this context, the small discharge dimensions enable very low gas flows in the range of <100 mL min-1; portability; the use of hydrogen, nitrogen, and air in addition to noble gases such as helium and argon, including its mixtures with propane; and application in microchip environments. By coupling FμTP with gas chromatography/mass spectrometry, we show that the polarity principle of the new discharge design allows it to outperform established ionization sources such as dielectric barrier discharge for soft ionization (DBDI) and low-temperature plasma (LTP) at low concentrations of perfluoroalkanes in terms of sensitivity, ionization efficiency, chemical background, linear dynamic range, and limit of detection by a large margin. In negative ion mode, the limit of detection is improved by more than 3-fold compared with that of DBDI and by 8-fold compared with that of LTP. The protonation capability was evaluated by headspace measurements of diisopropyl methylphosphonate in positive ion mode, showing low fragmentation and high stability in comparison to DBDI and LTP.
Collapse
Affiliation(s)
- Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Felix David Klute
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Alexander Schütz
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Ulrich Marggraf
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Carolin Drees
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Pascal Vogel
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Wolfgang Vautz
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V. , Bunsen-Kirchhoff-Str. 11 , 44139 Dortmund , Germany
| |
Collapse
|
17
|
Cai Y, Yu YL, Wang JH. Alternating-Current-Driven Microplasma for Multielement Excitation and Determination by Optical-Emission Spectrometry. Anal Chem 2018; 90:10607-10613. [PMID: 30070828 DOI: 10.1021/acs.analchem.8b02904] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Microplasma optical-emission spectrometry (OES) is a promising technique for developing portable analytical instrumentations for real-time and on-site measurement of trace elemental species. However, its analytical performance is far from satisfactory for multielement analysis. Herein, a miniature OES system is developed for simultaneous multielement analysis with alternating-current-driven microplasma generated on the nozzle of a pneumatic micronebulizer as the excitation source. Because of the strong excitation capability of the microplasma and its sufficient contact with solution, a series of elements, including Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, and Zn, is directly excited in the spray with solution nebulization at a flow rate of 8 μL s-1. The characteristic optical emissions are measured by a charge-coupled-device (CCD) spectrometer. In addition, hydride generation is compatible with the present system, which makes it feasible for the simultaneous excitation of hydrides of As, Ge, Hg, Sb, and Sn by reaction with 0.8% (m/v) NaBH4. The microplasma-OES system exhibits a powerful capability for multielement analysis with favorable limits of detection for the mentioned elements.
Collapse
Affiliation(s)
- Yi Cai
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences , Northeastern University , Box 332, Shenyang 110819 , China
| | - Yong-Liang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences , Northeastern University , Box 332, Shenyang 110819 , China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences , Northeastern University , Box 332, Shenyang 110819 , China
| |
Collapse
|