1
|
Wesdemiotis C, Williams-Pavlantos KN, Keating AR, McGee AS, Bochenek C. Mass spectrometry of polymers: A tutorial review. MASS SPECTROMETRY REVIEWS 2024; 43:427-476. [PMID: 37070280 DOI: 10.1002/mas.21844] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 03/03/2023] [Accepted: 03/17/2023] [Indexed: 06/19/2023]
Abstract
Ever since the inception of synthetic polymeric materials in the late 19th century, the number of studies on polymers as well as the complexity of their structures have only increased. The development and commercialization of new polymers with properties fine-tuned for specific technological, environmental, consumer, or biomedical applications requires powerful analytical techniques that permit the in-depth characterization of these materials. One such method with the ability to provide chemical composition and structure information with high sensitivity, selectivity, specificity, and speed is mass spectrometry (MS). This tutorial review presents and exemplifies the various MS techniques available for the elucidation of specific structural features in a synthetic polymer, including compositional complexity, primary structure, architecture, topology, and surface properties. Key to every MS analysis is sample conversion to gas-phase ions. This review describes the fundamentals of the most suitable ionization methods for synthetic materials and provides relevant sample preparation protocols. Most importantly, structural characterizations via one-step as well as hyphenated or multidimensional approaches are introduced and demonstrated with specific applications, including surface sensitive and imaging techniques. The aim of this tutorial review is to illustrate the capabilities of MS for the characterization of large, complex polymers and emphasize its potential as a powerful compositional and structural elucidation tool in polymer chemistry.
Collapse
Affiliation(s)
| | | | - Addie R Keating
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| | - Andrew S McGee
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| | - Calum Bochenek
- Department of Chemistry, The University of Akron, Akron, Ohio, USA
| |
Collapse
|
2
|
Morgan TE, Floyd TG, Marzullo BP, Wootton CA, Barrow MP, Bristow AWT, Perrier S, O'Connor PB. Stochasticity of poly(2-oxazoline) oligomer hydrolysis determined by tandem mass spectrometry. Polym Chem 2022; 13:4162-4169. [PMID: 35923808 PMCID: PMC9294869 DOI: 10.1039/d2py00437b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/01/2022] [Indexed: 11/30/2022]
Abstract
Understanding modification of synthetic polymer structures is necessary for their accurate synthesis and potential applications. In this contribution, a series of partially hydrolyzed poly(2-oxazoline) species were produced forming poly[(2-polyoxazoline)-co-(ethylenimine)] (P(EtOx-co-EI)) copolymers; EI being the hydrolyzed product of Ox. Bulk mass spectrometry (MS) measurements accurately measured the EI content. Tandem mass spectrometry analysis of the EI content in the copolymer samples determined the distribution of each monomer within the copolymer and corresponded to a theoretically modelled random distribution. The EI distribution across the polymers was shown to be effected by the choice of terminus, with a permanent hydrolysis event observed at an OH terminus. A neighbouring group effect wasn't observed at the polymer length analysed (approximately 25-mer species), suggesting that previously observed neighbouring group effects require a larger polymer chain. Although clearly useful for random polymer distribution this approach may be applied to many systems containing non-specific modifications to determine if they are directed or random locations across peptides, proteins, polymers, and nucleic acids. Tandem mass spectrometry can be used to better understand modification sites of synthetic polymer structures providing more complete chemical knowledge which is necessary for their accurate synthesis and potential applications.![]()
Collapse
Affiliation(s)
- Tomos E Morgan
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Thomas G Floyd
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Bryan P Marzullo
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | | | - Mark P Barrow
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| | - Anthony W T Bristow
- Chemical Development, Pharmaceutical Technology and Development, Operations, AstraZeneca Charter Way Macclesfield SK102NA UK
| | - Sébastien Perrier
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
- Warwick Medical School, University of Warwick Coventry CV4 7AL UK
- Faculty of Pharmaceutical Sciences, Monash University 381 Royal Parade Parkville VIC 3052 Australia
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick Coventry CV4 7AL UK
| |
Collapse
|
3
|
Morgan TE, Wootton CA, Marzullo B, Paris J, Kerr A, Ellacott SH, van Agthoven MA, Barrow MP, Bristow AWT, Perrier S, O'Connor PB. Characterization Across a Dispersity: Polymer Mass Spectrometry in the Second Dimension. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2153-2161. [PMID: 34264672 DOI: 10.1021/jasms.1c00106] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Due to the natural dispersity that is present in synthetic polymers, an added complexity is always present in the analysis of polymeric species. Tandem mass spectrometry analysis requires the isolation of individual precursors before a fragmentation event to allow the unambiguous characterization of these species and is not viable at certain levels of complexity due to achievable isolation widths. Two-dimensional mass spectrometry (2DMS) fragments ions and correlates fragments with their corresponding precursors without the need for isolation. In this study, 2DMS electron capture dissociation (ECD) fragmentation of a polyoxazoline and polyacrylamide species was carried out, resulting in the analysis of byproducts and individual polymer species without the use of chromatographic techniques. This study shows that 2DMS ECD is a powerful tool for the analysis of polyacrylamide and polyoxazoline species and offers a new dimension in the characterization of polymers.
Collapse
Affiliation(s)
- Tomos E Morgan
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Christopher A Wootton
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Bryan Marzullo
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Johanna Paris
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Andrew Kerr
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Sean H Ellacott
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Maria A van Agthoven
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Mark P Barrow
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| | - Anthony W T Bristow
- Chemical Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Macclesfield SK10 2NA, United Kingdom
| | - Sebastien Perrier
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
- Warwick Medical School, University of Warwick, Coventry CV4 7AL, United Kingdom
- Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Peter B O'Connor
- Department of Chemistry, University of Warwick, Coventry, West Midlands CV4 7AL, United Kingdom
| |
Collapse
|
4
|
Morgan TE, Kerr A, Wootton CA, Barrow MP, Bristow AW, Perrier S, O’Connor PB. Electron Capture Dissociation of Trithiocarbonate-Terminated Acrylamide Homo- and Copolymers: A Terminus-Directed Mechanism? Anal Chem 2020; 92:12852-12859. [DOI: 10.1021/acs.analchem.0c01224] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Tomos E. Morgan
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| | - Andrew Kerr
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| | | | - Mark P. Barrow
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| | - Anthony W.T. Bristow
- Chemical Development, Pharmaceutical Technology & Development, Operations, AstraZeneca, Macclesfield, Cheshire SK10 2NA, U.K
| | - Sébastien Perrier
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
- Warwick Medical School, University of Warwick, Coventry CV4 7AL, U.K
- Faculty of Pharmacy and Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Peter B. O’Connor
- Department of Chemistry, University of Warwick, Coventry, Midlands CV4 7AL, U.K
| |
Collapse
|
5
|
Ishitsuka K, Kakiuchi T, Sato H, Fouquet TNJ. An arsenal of tools based on Kendrick mass defects to process congested electrospray ionization high-resolution mass spectra of polymers with multiple charging. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 2:e8584. [PMID: 31517411 DOI: 10.1002/rcm.8584] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 08/30/2019] [Accepted: 09/04/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Electrospray ionization (ESI) favors the multiple charging of high molecular weight polymer samples and allows their high-resolution mass analysis in the low-mass range. It also induces the detection of numerous ion series at different charge states with different adducts complicating the interpretation of the mass spectrum which should be facilitated by an appropriate data processing. METHODS An arsenal of tools based on the Kendrick mass defect (KMD) is proposed to process congested ESI high-resolution mass spectra of poly(propylene oxide) (PPO) samples. The combination of regular, charge-dependent, and resolution-enhanced KMD plots in addition to a "remainders" plot and a new three-dimensional plot offers unrivaled capabilities of filtering for any minor series among thousands of points. The sequential data processing is conducted using Kendo, a spreadsheet developed in-house for an advanced KMD analysis. RESULTS The charge-state distribution is easily evaluated by counting the parallel lines in a regular KMD plot. A charge-dependent resolution-enhanced KMD plot instantly reveals the variation of adducted ions at a given charge state, helping the user to choose the best analytical conditions. Ion series at different charge states from PPO oligomers carrying different end-groups are also efficiently extracted using several combinations of KMD and remainders plots and assigned using a new simulator tool. CONCLUSIONS The innovative combination of existing and new KMD-related plots, selection tools, and simulator all combined in a single spreadsheet dramatically facilitates the processing and interpretation of complex ESI mass spectral data. The presented tools may be extended to any other class of homo-, co- and terpolymers.
Collapse
Affiliation(s)
- Kei Ishitsuka
- Analytical Science Team, Common Base Technology Division, Innovative Technology Laboratories, AGC Inc., Yokohama, Japan
| | - Toshifumi Kakiuchi
- Analytical Science Team, Common Base Technology Division, Innovative Technology Laboratories, AGC Inc., Yokohama, Japan
| | - Hiroaki Sato
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| | - Thierry N J Fouquet
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| |
Collapse
|
6
|
Fouquet TNJ. The Kendrick analysis for polymer mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:933-947. [PMID: 31758605 DOI: 10.1002/jms.4480] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Revised: 11/18/2019] [Accepted: 11/19/2019] [Indexed: 05/16/2023]
Abstract
The mass spectrum of a polymer often displays repetitive patterns with peak series spaced by the repeating unit(s) of the polymeric backbones, sometimes complexified with different adducts, chain terminations, or charge states. Exploring the complex mass spectral data or filtering the unwanted signal is tedious whether performed manually or automatically. In contrast, the now 60-year-old Kendrick (mass defect) analysis, when adapted to polymer ions, produces visual two-dimensional maps with intuitive alignments of the repetitive patterns and favourable deconvolution of features overlaid in the one-dimensional mass spectrum. This special feature article reports on an up-to-date and theoretically sound use of Kendrick plots as a data processing tool. The approach requires no prior knowledge of the sample but offers promising dynamic capabilities for visualizing, filtering, and sometimes assigning congested mass spectra. Examples of applications of the approach to polymers are discussed throughout the text, but the same tools can be readily extended to other applications, including the analysis of polymers present as pollutants/contaminants, and to other analytes incorporating a repetitive moiety, for example, oils or lipids. In each of these instances, data processing can benefit from the application of an updated and interactive Kendrick analysis.
Collapse
Affiliation(s)
- Thierry N J Fouquet
- Research Institute for Sustainable Chemistry (RISC), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| |
Collapse
|
7
|
|
8
|
Fouquet TNJ, Nakamura S, Sato H, Cody RB. Real divisors and pseudo-continuous enhancement of resolution for a Kendrick mass defect analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:1547-1551. [PMID: 31162755 DOI: 10.1002/rcm.8500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2019] [Revised: 05/17/2019] [Accepted: 05/27/2019] [Indexed: 06/09/2023]
Affiliation(s)
- Thierry N J Fouquet
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| | - Sayaka Nakamura
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| | - Hiroaki Sato
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, Japan
| | | |
Collapse
|
9
|
Kune C, McCann A, Raphaël LR, Arias AA, Tiquet M, Van Kruining D, Martinez PM, Ongena M, Eppe G, Quinton L, Far J, De Pauw E. Rapid Visualization of Chemically Related Compounds Using Kendrick Mass Defect As a Filter in Mass Spectrometry Imaging. Anal Chem 2019; 91:13112-13118. [DOI: 10.1021/acs.analchem.9b03333] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Christopher Kune
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - Andréa McCann
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - La Rocca Raphaël
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - Anthony Arguelles Arias
- Microbial Processes and Interactions, Gembloux Agro-Bio Tech, TERRA Teaching and Research Centre, University of Liege, Gembloux, Belgium
| | - Mathieu Tiquet
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - Daan Van Kruining
- Department of Psychiatry and Neuropsychology, School for Mental Health and Neuroscience, Maastricht University, Maastricht, The Netherlands
| | - Pilar Martinez Martinez
- Department of Psychiatry and Neuropsychology, School for Mental Health and Neuroscience, Maastricht University, Maastricht, The Netherlands
| | - Marc Ongena
- Microbial Processes and Interactions, Gembloux Agro-Bio Tech, TERRA Teaching and Research Centre, University of Liege, Gembloux, Belgium
| | - Gauthier Eppe
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - Loïc Quinton
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - Johann Far
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| | - Edwin De Pauw
- Mass Spectrometry Laboratory, MolSys Research Unit, University of Liège, Liège, Belgium
| |
Collapse
|
10
|
Town JS, Jones GR, Hancox E, Shegiwal A, Haddleton DM. Tandem Mass Spectrometry for Polymeric Structure Analysis: A Comparison of Two Common MALDI–ToF/ToF Techniques. Macromol Rapid Commun 2019; 40:e1900088. [DOI: 10.1002/marc.201900088] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 04/09/2019] [Indexed: 11/10/2022]
Affiliation(s)
- James S. Town
- Department of ChemistryUniversity of Warwick CV4 7AL UK
| | - Glen R. Jones
- Department of ChemistryUniversity of Warwick CV4 7AL UK
| | - Ellis Hancox
- Department of ChemistryUniversity of Warwick CV4 7AL UK
| | | | | |
Collapse
|
11
|
Nakamura S, Cody RB, Sato H, Fouquet T. Graphical Ranking of Divisors to Get the Most out of a Resolution-Enhanced Kendrick Mass Defect Plot. Anal Chem 2018; 91:2004-2012. [DOI: 10.1021/acs.analchem.8b04371] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Sayaka Nakamura
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8560, Japan
| | - Robert B. Cody
- JEOL USA Inc., Peabody, Massachusetts 01960, United States
| | - Hiroaki Sato
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8560, Japan
| | - Thierry Fouquet
- Research Institute for Sustainable Chemistry, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8560, Japan
| |
Collapse
|