1
|
Wang R, Chen K, Liu S, Ren R, Hou H, Zeng Q, Zhang Y, Liu Y. Design, synthesis and biological evaluation of novel oxazole derivatives as potential hypoglycemic agents. Bioorg Med Chem 2024; 114:117961. [PMID: 39437535 DOI: 10.1016/j.bmc.2024.117961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 10/25/2024]
Abstract
A series of 2,4-disubstituted-oxazole derivatives have been designed and synthesized based on compound 3a, a promising lead compound developed in our lab. Among these derivatives, the optimized compound 5k exhibited potent hypoglycemic activity, increasing glucose consumption by 60 % in HepG2 cells compared to the solvent control, and its activity was higher than that of metformin. Further investigation indicated that compound 5k exhibited negligible cytotoxic effects at a concentration of 25 μM in HepG2 and 3T3-L1 cells and showed moderate inhibitory activity against various subtypes of human cytochrome P450 subtypes. An oral glucose tolerance test confirmed that 5k is an effective hypoglycemic agent. Additionally, mechanistic studies suggested that 5k may exert its hypoglycemic activity through the activation of the AMPK pathway.
Collapse
Affiliation(s)
- Ruifeng Wang
- Department of Endocrinology, First Hospital of Shanxi Medical University, Shanxi Medical University, Taiyuan 030001, China; School of Pharmacy, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China
| | - Ke Chen
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China
| | - Shuihua Liu
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China
| | - Ruyue Ren
- School of Pharmacy, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China
| | - Hongbao Hou
- Department of Pharmacology, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China
| | - Qingxuan Zeng
- Department of Pharmacology, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China
| | - Yi Zhang
- Department of Pharmacology, Shanxi Medical University, Taiyuan 030001, China; Medicinal Basic Research Innovation Center of Chronic Kidney Disease, Ministry of Education, Shanxi Medical University, Taiyuan 030001, China.
| | - Yunfeng Liu
- Department of Endocrinology, First Hospital of Shanxi Medical University, Shanxi Medical University, Taiyuan 030001, China.
| |
Collapse
|
2
|
Lynch EM, Hansen H, Salay L, Cooper M, Timr S, Kollman JM, Webb BA. Structural basis for allosteric regulation of human phosphofructokinase-1. Nat Commun 2024; 15:7323. [PMID: 39183237 PMCID: PMC11345425 DOI: 10.1038/s41467-024-51808-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Accepted: 08/19/2024] [Indexed: 08/27/2024] Open
Abstract
Phosphofructokinase-1 (PFK1) catalyzes the rate-limiting step of glycolysis, committing glucose to conversion into cellular energy. PFK1 is highly regulated to respond to the changing energy needs of the cell. In bacteria, the structural basis of PFK1 regulation is a textbook example of allostery; molecular signals of low and high cellular energy promote transition between an active R-state and inactive T-state conformation, respectively. Little is known, however, about the structural basis for regulation of eukaryotic PFK1. Here, we determine structures of the human liver isoform of PFK1 (PFKL) in the R- and T-state by cryoEM, providing insight into eukaryotic PFK1 allosteric regulatory mechanisms. The T-state structure reveals conformational differences between the bacterial and eukaryotic enzyme, the mechanisms of allosteric inhibition by ATP binding at multiple sites, and an autoinhibitory role of the C-terminus in stabilizing the T-state. We also determine structures of PFKL filaments that define the mechanism of higher-order assembly and demonstrate that these structures are necessary for higher-order assembly of PFKL in cells.
Collapse
Affiliation(s)
- Eric M Lynch
- Department of Biochemistry, University of Washington, Seattle, WA, USA
| | - Heather Hansen
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA
| | - Lauren Salay
- Department of Biochemistry, University of Washington, Seattle, WA, USA
| | - Madison Cooper
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA
| | - Stepan Timr
- Department of Computational Chemistry, J. Heyrovsky Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czech Republic
| | - Justin M Kollman
- Department of Biochemistry, University of Washington, Seattle, WA, USA.
| | - Bradley A Webb
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV, USA.
| |
Collapse
|
3
|
Wu J, Zhou X, Sun H, Yu D. Optimization of Extraction Conditions for Water-Soluble Polysaccharides from the Roots of Adenophora tetraphylla (Thunb.) Fisch. and Its Effects on Glucose Consumption on HepG2 Cells. Molecules 2024; 29:3049. [PMID: 38999001 PMCID: PMC11243351 DOI: 10.3390/molecules29133049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 06/13/2024] [Accepted: 06/18/2024] [Indexed: 07/14/2024] Open
Abstract
The root of Adenophora tetraphylla (Thunb.) Fisch. is a common Chinese materia medica and the polysaccharides which have been isolated from the plant are important active components for medicinal purposes. The objective of the current study was to optimize the extraction parameters and evaluate the glucose consumption activity for Adenophorae root polysaccharides (ARPs). The optimization of ARP extraction was evaluated with preliminary experiments and using response surface methodology (RSM). The conditions investigated were 35-45 °C extraction temperature, 20-30 (v/w) water-to-solid ratio, and 3-5 h extraction time. The antidiabetic effects of ARPs for the glucose consumption activity were evaluated in HepG2 cells. The statistical analyses of the experiments indicated that temperature, water-to-solid ratio, and extraction time significantly affected ARP yield (p < 0.01). The correlation analysis revealed that the experimental data were well-aligned with a quadratic polynomial model, as evidenced by the mathematical regression model's fit. The optimal conditions for maximum ARP yield were 45 °C extraction temperature and 28.47:1 (mL/g) water-to-solid ratio with a 4.60 h extraction time. Extracts from these conditions showed significant activity of promoting cell proliferation from 11.26% (p < 0.001) to 32.47% (p < 0.001) at a dose of 50 μg/mL to 800 μg/mL and increasing glucose consumption to 75.86% (p < 0.001) at 250 μg/mL on HepG2 cells. This study provides a sustainable alternative for the industry since it allowed simplified handling and a specific quantity of ARPs. Furthermore, ARPs might directly stimulate the glucose consumption in the liver and showed no cytotoxicity; therefore, ARPs probably could be taken as a potential natural source of antidiabetic materials.
Collapse
Affiliation(s)
- Junkai Wu
- School of Pharmacy, Quanzhou Medical College, Quanzhou 362011, China
| | - Xiaohang Zhou
- Pharmaceutical College, Heilongjiang University of Chinese Medicine, Harbin 150040, China
| | - Huifeng Sun
- Pharmaceutical College, Heilongjiang University of Chinese Medicine, Harbin 150040, China
| | - Dan Yu
- Pharmaceutical College, Heilongjiang University of Chinese Medicine, Harbin 150040, China
| |
Collapse
|
4
|
Lynch EM, Hansen H, Salay L, Cooper M, Timr S, Kollman JM, Webb BA. Structural basis for allosteric regulation of human phosphofructokinase-1. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.03.15.585110. [PMID: 38559074 PMCID: PMC10980016 DOI: 10.1101/2024.03.15.585110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
Phosphofructokinase-1 (PFK1) catalyzes the rate-limiting step of glycolysis, committing glucose to conversion into cellular energy. PFK1 is highly regulated to respond to the changing energy needs of the cell. In bacteria, the structural basis of PFK1 regulation is a textbook example of allostery; molecular signals of low and high cellular energy promote transition between an active R-state and inactive T-state conformation, respectively Little is known, however, about the structural basis for regulation of eukaryotic PFK1. Here, we determine structures of the human liver isoform of PFK1 (PFKL) in the R- and T-state by cryoEM, providing insight into eukaryotic PFK1 allosteric regulatory mechanisms. The T-state structure reveals conformational differences between the bacterial and eukaryotic enzyme, the mechanisms of allosteric inhibition by ATP binding at multiple sites, and an autoinhibitory role of the C-terminus in stabilizing the T-state. We also determine structures of PFKL filaments that define the mechanism of higher-order assembly and demonstrate that these structures are necessary for higher-order assembly of PFKL in cells.
Collapse
Affiliation(s)
- Eric M Lynch
- Department of Biochemistry, University of Washington
| | - Heather Hansen
- Department of Biochemistry and Molecular Medicine, West Virginia University
| | - Lauren Salay
- Department of Biochemistry, University of Washington
| | - Madison Cooper
- Department of Biochemistry and Molecular Medicine, West Virginia University
| | - Stepan Timr
- Department of Computational Chemistry, J. Heyrovsky Institute of Physical Chemistry, Czech Academy of Sciences
| | | | - Bradley A Webb
- Department of Biochemistry and Molecular Medicine, West Virginia University
| |
Collapse
|
5
|
de Hoyos-Vega JM, Gonzalez-Suarez AM, Cedillo-Alcantar DF, Stybayeva G, Matveyenko A, Malhi H, Garcia-Cordero JL, Revzin A. Microfluidic 3D hepatic cultures integrated with a droplet-based bioanalysis unit. Biosens Bioelectron 2024; 248:115896. [PMID: 38176252 PMCID: PMC10916504 DOI: 10.1016/j.bios.2023.115896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 11/03/2023] [Accepted: 11/27/2023] [Indexed: 01/06/2024]
Abstract
A common challenge in microfluidic cell cultures has to do with analysis of cell function without replacing a significant fraction of the culture volume and disturbing local concentration gradients of signals. To address this challenge, we developed a microfluidic cell culture device with an integrated bioanalysis unit to enable on-chip analysis of picoliter volumes of cell-conditioned media. The culture module consisted of an array of 140 microwells with a diameter of 300 m which were made low-binding to promote organization of cells into 3D spheroids. The bioanalysis module contained a droplet generator unit, 15 micromechanical valves and reservoirs loaded with reagents. Each 0.8 nL droplet contained an aliquot of conditioned media mixed with assay reagents. The use of microvalves allowed us to load enzymatic assay and immunoassay into sequentially generated droplets for detection of glucose and albumin, respectively. As a biological application of the microfluidic device, we evaluated hormonal stimulation and glucose consumption of hepatic spheroids. To mimic physiological processes occurring during feeding and fasting, hepatic spheroids were exposed to pancreatic hormones, insulin or glucagon. The droplet-based bioanalysis module was used to measure uptake or release of glucose upon hormonal stimulation. In the future, we intend to use this microfluidic device to mimic and measure pathophysiological processes associated with hepatic insulin resistance and diabetes in the context of metabolic syndrome.
Collapse
Affiliation(s)
- Jose M de Hoyos-Vega
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | | - Diana F Cedillo-Alcantar
- Laboratory of Microtechnologies Applied to Biomedicine, Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Aleksey Matveyenko
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Harmeet Malhi
- Division of Gastroenterology and Hepatology, Mayo Clinic, MN, USA
| | - Jose L Garcia-Cordero
- Laboratory of Microtechnologies Applied to Biomedicine, Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
6
|
Fernandes J, Karra N, Swindle EJ, Morgan H. Droplet fluidics for time-dependent analysis of barrier permeability in an epithelial barrier on chip system. RSC Adv 2023; 13:14494-14500. [PMID: 37179995 PMCID: PMC10173818 DOI: 10.1039/d3ra00470h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Accepted: 05/03/2023] [Indexed: 05/15/2023] Open
Abstract
A droplet generator has been developed that interfaces with a barrier-on-chip platform for temporal analyte compartmentalisation and analysis. Droplets are generated every 20 minutes in 8 separate parallel microchannels, with an average droplet volume of 9.47 ± 0.6 μL, allowing simultaneous analysis of 8 different experiments. The device was tested using an epithelial barrier model by monitoring the diffusion of a fluorescent high molecular weight dextran molecule. The epithelial barrier was perturbed using detergent leading to a peak at 3-4 hours, correlating with simulations. For the untreated (control) a constant, very low level of dextran diffusion was observed. The epithelial cell barrier properties were also continuously measured using electrical impedance spectroscopy to extract an equivalent trans epithelial resistance.
Collapse
Affiliation(s)
- Joao Fernandes
- Electronics and Computer Science, Faculty of Physical Sciences and Engineering, University of Southampton UK
| | - Nikita Karra
- Electronics and Computer Science, Faculty of Physical Sciences and Engineering, University of Southampton UK
| | - Emily J Swindle
- Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton UK
- Institute for Life Sciences, University of Southampton UK
- NIHR Southampton Biomedical Research Centre, University Hospital Southampton UK
| | - Hywel Morgan
- Electronics and Computer Science, Faculty of Physical Sciences and Engineering, University of Southampton UK
- Institute for Life Sciences, University of Southampton UK
| |
Collapse
|
7
|
Lapizco-Encinas BH, Zhang YV. Microfluidic systems in clinical diagnosis. Electrophoresis 2023; 44:217-245. [PMID: 35977346 DOI: 10.1002/elps.202200150] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 08/10/2022] [Accepted: 08/11/2022] [Indexed: 02/01/2023]
Abstract
The use of microfluidic devices is highly attractive in the field of biomedical and clinical assessments, as their portability and fast response time have become crucial in providing opportune therapeutic treatments to patients. The applications of microfluidics in clinical diagnosis and point-of-care devices are continuously growing. The present review article discusses three main fields where miniaturized devices are successfully employed in clinical applications. The quantification of ions, sugars, and small metabolites is examined considering the analysis of bodily fluids samples and the quantification of this type of analytes employing real-time wearable devices. The discussion covers the level of maturity that the devices have reached as well as cost-effectiveness. The analysis of proteins with clinical relevance is presented and organized by the function of the proteins. The last section covers devices that can perform single-cell metabolomic and proteomic assessments. Each section discusses several strategically selected recent reports on microfluidic devices successfully employed for clinical assessments, to provide the reader with a wide overview of the plethora of novel systems and microdevices developed in the last 5 years. In each section, the novel aspects and main contributions of each reviewed report are highlighted. Finally, the conclusions and future outlook section present a summary and speculate on the future direction of the field of miniaturized devices for clinical applications.
Collapse
Affiliation(s)
- Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, Rochester, New York, USA
| | - Yan Victoria Zhang
- Department of Pathology and Laboratory Medicine, University of Rochester Medical Center, Rochester, New York, USA
| |
Collapse
|
8
|
Abstract
Cell manipulation in droplets has emerged as one of the great successes of microfluidic technologies, with the development of single-cell screening. However, the droplet format has also served to go beyond single-cell studies, namely by considering the interactions between different cells or between cells and their physical or chemical environment. These studies pose specific challenges linked to the need for long-term culture of adherent cells or the diverse types of measurements associated with complex biological phenomena. Here we review the emergence of droplet microfluidic methods for culturing cells and studying their interactions. We begin by characterizing the quantitative aspects that determine the ability to encapsulate cells, transport molecules, and provide sufficient nutrients within the droplets. This is followed by an evaluation of the biological constraints such as the control of the biochemical environment and promoting the anchorage of adherent cells. This first part ends with a description of measurement methods that have been developed. The second part of the manuscript focuses on applications of these technologies for cancer studies, immunology, and stem cells while paying special attention to the biological relevance of the cellular assays and providing guidelines on improving this relevance.
Collapse
Affiliation(s)
- Sébastien Sart
- LadHyX, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France.,Physical Microfluidics and Bioengineering, Institut Pasteur, 25-28 Rue du Dr. Roux, 75015 Paris, France
| | - Gustave Ronteix
- LadHyX, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France.,Physical Microfluidics and Bioengineering, Institut Pasteur, 25-28 Rue du Dr. Roux, 75015 Paris, France
| | - Shreyansh Jain
- LadHyX, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France.,Physical Microfluidics and Bioengineering, Institut Pasteur, 25-28 Rue du Dr. Roux, 75015 Paris, France
| | - Gabriel Amselem
- LadHyX, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France.,Physical Microfluidics and Bioengineering, Institut Pasteur, 25-28 Rue du Dr. Roux, 75015 Paris, France
| | - Charles N Baroud
- LadHyX, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France.,Physical Microfluidics and Bioengineering, Institut Pasteur, 25-28 Rue du Dr. Roux, 75015 Paris, France
| |
Collapse
|
9
|
Abstract
Manipulation of fluid flow is paramount for microfluidic device operation. Conventional microfluidic pumps are often expensive, bulky, complicated, and not amenable in limited resource settings. Here, we introduce a Fully self-sufficient, RobUst, Gravity-Assisted, Low-cost (FRUGAL) microfluidic pump. The pump consists of a syringe, a syringe holder and loading masses. The system is easy to assemble, inexpensive, portable, and electrical power-free. Inside the syringe, the fluid is driven by the pressure from the weight of the loading masses. During operation, the exerted pressure is dynamically controllable and stable for hours. These features are useful for optimization of microfluidics assays and dynamic temporal studies. We demonstrate the application of this system to control the formation of water-in-oil droplet emulsion. Benefitting from its simplicity and versatility, the frugal microfluidic pump will enable global adoption of microfluidic technology in chemistry and biomedical applications, especially in limited resource environments.
Collapse
Affiliation(s)
- Apresio K Fajrial
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, 80309, USA.
| | - Adam Vega
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, 80309, USA.
| | - Gazendra Shakya
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, 80309, USA.
| | - Xiaoyun Ding
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, 80309, USA.
- Biomedical Engineering Program, University of Colorado Boulder, Boulder, CO, 80309, USA
| |
Collapse
|
10
|
Eaton WJ, Roper MG. A microfluidic system for monitoring glucagon secretion from human pancreatic islets of Langerhans. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3614-3619. [PMID: 34308945 PMCID: PMC8375491 DOI: 10.1039/d1ay00703c] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Glucagon is a 29-amino acid peptide released from α-cells within pancreatic islets of Langerhans to help raise blood glucose levels. While a plethora of methodologies have been developed for quantitative measurement of insulin released from islets, such methods are not well developed for glucagon despite its importance in blood sugar regulation. In this work, a simple yet robust microfluidic device was developed for holding human pancreatic islets and perfuse them with glucose. The perfusate was collected into 2 min fractions and glucagon quantified using a homogeneous time-resolved Förster resonance energy transfer (TR-FRET) sandwich immunoassay. Simulation of fluid flow within the microfluidic device indicated the device produced low amounts of shear stress on islets, and characterization of the flow with standard glucagon solutions revealed response times within 2 fractions (<4 min). Results with human islets from multiple donors demonstrated either a "burst" of glucagon or a "sustained" glucagon release across the entire period of stimulation. The simplicity, yet robustness, of the device and method is expected to appeal to a number of researchers examining pancreatic islet physiology.
Collapse
Affiliation(s)
- Wesley J. Eaton
- Department of Chemistry and Biochemistry, Florida State University95 Chieftain WayTallahasseeFL 32306USA+1-850-644-1846
| | - Michael G. Roper
- Department of Chemistry and Biochemistry, Florida State University95 Chieftain WayTallahasseeFL 32306USA+1-850-644-1846
| |
Collapse
|
11
|
Djisalov M, Knežić T, Podunavac I, Živojević K, Radonic V, Knežević NŽ, Bobrinetskiy I, Gadjanski I. Cultivating Multidisciplinarity: Manufacturing and Sensing Challenges in Cultured Meat Production. BIOLOGY 2021; 10:204. [PMID: 33803111 PMCID: PMC7998526 DOI: 10.3390/biology10030204] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Revised: 02/28/2021] [Accepted: 03/02/2021] [Indexed: 12/11/2022]
Abstract
Meat cultivation via cellular agriculture holds great promise as a method for future food production. In theory, it is an ideal way of meat production, humane to the animals and sustainable for the environment, while keeping the same taste and nutritional values as traditional meat and having additional benefits such as controlled fat content and absence of antibiotics and hormones used in the traditional meat industry. However, in practice, there is still a number of challenges, such as those associated with the upscale of cultured meat (CM). CM food safety monitoring is a necessary factor when envisioning both the regulatory compliance and consumer acceptance. To achieve this, a multidisciplinary approach is necessary. This includes extensive development of the sensitive and specific analytical devices i.e., sensors to enable reliable food safety monitoring throughout the whole future food supply chain. In addition, advanced monitoring options can help in the further optimization of the meat cultivation which may reduce the currently still high costs of production. This review presents an overview of the sensor monitoring options for the most relevant parameters of importance for meat cultivation. Examples of the various types of sensors that can potentially be used in CM production are provided and the options for their integration into bioreactors, as well as suggestions on further improvements and more advanced integration approaches. In favor of the multidisciplinary approach, we also include an overview of the bioreactor types, scaffolding options as well as imaging techniques relevant for CM research. Furthermore, we briefly present the current status of the CM research and related regulation, societal aspects and challenges to its upscaling and commercialization.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Ivana Gadjanski
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjica 1, 21000 Novi Sad, Serbia; (M.Dj.); (T.K.); (I.P.); (K.Ž.); (V.R.); (N.Ž.K.); (I.B.)
| |
Collapse
|
12
|
Didier P, Lobato‐Dauzier N, Clément N, Genot AJ, Sasaki Y, Leclerc É, Minamiki T, Sakai Y, Fujii T, Minami T. Microfluidic System with Extended‐Gate‐Type Organic Transistor for Real‐Time Glucose Monitoring. ChemElectroChem 2020. [DOI: 10.1002/celc.201902013] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Pierre Didier
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Nicolas Lobato‐Dauzier
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Nicolas Clément
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Anthony J. Genot
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Yui Sasaki
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Éric Leclerc
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Tsukuru Minamiki
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Yasuyuki Sakai
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- Department of Chemical System Engineering The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku Tokyo 113-8656 Japan
| | - Teruo Fujii
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| | - Tsuyoshi Minami
- Institute of Industrial Science The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
- LIMMS/CNRS-IIS (UMI2820) The University of Tokyo 4-6-1 Komaba, Meguro-ku Tokyo 153-8505 Japan
| |
Collapse
|