1
|
Diao Z, Feng G, Xu W, Zhu F, Zhang Y, Duan J, Xu M, Zhang X, Zhang X, Zhao S, Wang S, Yuan X. Development of diffusive gradients in thin-films technique for monitoring polycyclic aromatic hydrocarbons in coastal waters. JOURNAL OF HAZARDOUS MATERIALS 2024; 471:134384. [PMID: 38663292 DOI: 10.1016/j.jhazmat.2024.134384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 04/17/2024] [Accepted: 04/20/2024] [Indexed: 05/12/2024]
Abstract
Addressing the challenge of accurately monitoring polycyclic aromatic hydrocarbons (PAHs) in aquatic systems, this study employed diffusive gradients in thin-films (DGT) technique to achieve methods detection limits as low as 0.02 ng L-1 to 0.05 ng L-1 through in situ preconcentration and determination of time-integrated concentrations. The efficacy of the developed DGT samplers was validated under diverse environmental conditions, demonstrating independence from factors such as pH (5.03-9.01), dissolved organic matter (0-20 mg L-1), and ionic strength (0.0001-0.6 M). Notably, the introduction of a novel theoretical approach to calculate diffusion coefficients based on solvent-accessible volume tailored for PAHs significantly enhanced the method's applicability, particularly for organic pollutants with low solubility. Field deployments in coastal zones validated the DGT method against traditional grab sampling, with findings advocating a 4 to 7-day optimal deployment duration for balancing sensitivity and mitigating lag time effects. These results provide a sophisticated, efficient solution to the persistent challenge of monitoring hydrophobic organic pollutants in aquatic environments, broadening the scope and applicability of DGT in environmental science and providing a robust tool for researchers.
Collapse
Affiliation(s)
- Zishan Diao
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China; Shandong Key Laboratory of Environmental Processes and Health, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China
| | - Guoqin Feng
- Shanghai Hansoh Biomedical, Shanghai 201203, PR China
| | - Weikun Xu
- National Deep-Sea Center, Qingdao, Shandong 266237, PR China
| | - Fanping Zhu
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China; Sino-French Research Institute for Ecology and Environment, Shandong University, Qingdao, Shandong 266237, PR China
| | - Yiqiao Zhang
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China
| | - Jianlu Duan
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China
| | - Mengxin Xu
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China
| | - Xue Zhang
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China
| | - Xiaohan Zhang
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China; Shandong Key Laboratory of Environmental Processes and Health, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China.
| | - Shan Zhao
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China; Shandong Key Laboratory of Environmental Processes and Health, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China
| | - Shuguang Wang
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China; Sino-French Research Institute for Ecology and Environment, Shandong University, Qingdao, Shandong 266237, PR China; WeiHai Research Institute of Industrial Technology of Shandong University, Weihai 264209, PR China
| | - Xianzheng Yuan
- Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao, Shandong 266237, PR China; Sino-French Research Institute for Ecology and Environment, Shandong University, Qingdao, Shandong 266237, PR China
| |
Collapse
|
2
|
Rong Q, Li Y, Luo J, Yan L, Jones KC, Zhang H. Development of a novel DGT passive sampler for measuring polycyclic aromatic hydrocarbons in aquatic systems. JOURNAL OF HAZARDOUS MATERIALS 2024; 470:134199. [PMID: 38593660 DOI: 10.1016/j.jhazmat.2024.134199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Revised: 03/22/2024] [Accepted: 03/31/2024] [Indexed: 04/11/2024]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants and need to be measured reliably in waters and other media, to understand their sources, fate, behaviour and to meet regulatory monitoring requirements. Conventional water sampling requires large water volumes, time-consuming pre-concentration and clean-up and is prone to analyte loss or contamination. Here, for the first time, we developed and validated a novel diffusive gradients in thin-films (DGT) passive sampler for PAHs. Based on the well-known DGT principles, the sampler pre-concentrates PAHs with typical deployment times of days/weeks, with minimal sample handling. For the first time, DGT holding devices made of metal and suitable for sampling hydrophobic organic compounds were designed and tested. They minimize sorption and sampling lag times. Following tests on different binding layer resins, a MIP-DGT was preferred - the first time applying MIP for PAHs. It samples PAHs independent of pH (3.9 -8.1), ionic strength (0.01 -0.5 M) and dissolved organic matter < 20 mg L-1, making it suitable for applications across a wide range of environments. Field trials in river water and wastewater demonstrated that DGT is a convenient and reliable tool for monitoring labile PAHs, readily achieving quantitative detection of environmental levels (sub-ng and ng/L range) when coupled with conventional GC-MS or HPLC. ENVIRONMENTAL IMPLICATIONS: PAHs are carcinogenic and genotoxic compounds. They are environmentally ubiquitous and must be monitored in waters and other media. This study successfully developed a new DGT passive sampler for reliable in situ time-integrated measurements of PAHs in waters at the ng/L level. This is the first time to use passive samplers for accurate measurements of hydrophobic organic contaminants in aquatic systems without calibration, a big step forward in monitoring PAHs. The application of this new sampler will enhance our understanding of the sources, fate, behavior and ecotoxicology of PAHs, enabling improved environmental risk assessment and management of these compounds.
Collapse
Affiliation(s)
- Qiuyu Rong
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Yanying Li
- College of Environmental Science and Engineering, Dalian Maritime University, Dalian, Liaoning 116023, PR China
| | - Jun Luo
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023 PR China
| | - Liying Yan
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023 PR China
| | - Kevin C Jones
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom.
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom.
| |
Collapse
|
3
|
Dong F, Ge F, Zhao X, Sun D, Ren S, Wang Y, Tan F. Measurement of perfluoroalkyl substances in drinking water sources by DGT sampler with a novel fluorinated graphite binding gel. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:169658. [PMID: 38159764 DOI: 10.1016/j.scitotenv.2023.169658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 01/03/2024]
Abstract
Extensive use of per- and polyfluoroalkyl substances (PFASs) has resulted in their widespread presence in natural waters. Concern for public health requires reliable measurement methods for determining their distribution and risks. Here, a sampling method based on diffusive gradients in thin films (DGT) was developed for measuring PFASs in drinking water sources. Fluorinated graphite (FG) particles were used to prepare the DGT binding gel for selective enrichment of trace PFASs in an aqueous environment. The FG-DGT method did not show sensitivity to relevant environmental parameters including pH (5.0-9.0), ionic strength (0.001-0.5 M), or DOM concentration (0-30 mg/L). The FG-DGT had enough capacity for deployment of up to four months. Six traditional and emerging PFASs including PFOS, PFOA, PFHpA, PFHxS, PFNA, and 6:2 FTSA at the ng/L level were detected in two major reservoirs serving as public drinking water sources by FG-DGT method coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). PFOA appeared at the highest observed concentrations in the drinking water sources. The research demonstrates that FG-DGT is an effective and efficient tool for monitoring PFASs in drinking water.
Collapse
Affiliation(s)
- Fan Dong
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Fan Ge
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Xinting Zhao
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Daming Sun
- Dalian Hydrological Bureau of Liaoning Province, Dalian 116023, China
| | - Suyu Ren
- School of Environmental and Material Engineering, Yantai University, Yan Tai 264005, China
| | - Yan Wang
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Feng Tan
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
| |
Collapse
|
4
|
Kramer L, Schulze T, Klüver N, Altenburger R, Hackermüller J, Krauss M, Busch W. Curated mode-of-action data and effect concentrations for chemicals relevant for the aquatic environment. Sci Data 2024; 11:60. [PMID: 38200014 PMCID: PMC10781676 DOI: 10.1038/s41597-023-02904-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 12/29/2023] [Indexed: 01/12/2024] Open
Abstract
Chemicals in the aquatic environment can be harmful to organisms and ecosystems. Knowledge on effect concentrations as well as on mechanisms and modes of interaction with biological molecules and signaling pathways is necessary to perform chemical risk assessment and identify toxic compounds. To this end, we developed criteria and a pipeline for harvesting and summarizing effect concentrations from the US ECOTOX database for the three aquatic species groups algae, crustaceans, and fish and researched the modes of action of more than 3,300 environmentally relevant chemicals in literature and databases. We provide a curated dataset ready to be used for risk assessment based on monitoring data and the first comprehensive collection and categorization of modes of action of environmental chemicals. Authorities, regulators, and scientists can use this data for the grouping of chemicals, the establishment of meaningful assessment groups, and the development of in vitro and in silico approaches for chemical testing and assessment.
Collapse
Affiliation(s)
- Lena Kramer
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany
| | - Tobias Schulze
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany.
| | - Nils Klüver
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany
| | - Rolf Altenburger
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany
- RWTH Aachen University, Institute for Environmental Research, 52074, Aachen, Germany
| | - Jörg Hackermüller
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany
- University of Leipzig, Faculty of Mathematics and Computer Science, Ritterstr. 26, 04109, Leipzig, Germany
| | - Martin Krauss
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany
| | - Wibke Busch
- Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, 04318, Leipzig, Germany.
| |
Collapse
|
5
|
Fialová P, Grabic R, Grabicová K, Nováková P, Švecová H, Kaserzon S, Thompson K, Vrana B. Performance evaluation of a diffusive hydrogel-based passive sampler for monitoring of polar organic compounds in wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 864:161071. [PMID: 36565860 DOI: 10.1016/j.scitotenv.2022.161071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 12/15/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
An upscaled passive sampler variant (diffusive hydrogel-based passive sampler; HPS) based on diffusive gradients in thin films for polar organic compounds (o-DGT) with seven times higher surface area (22.7 cm2) than a typical o-DGT sampler (3.14 cm2) was tested in several field studies. HPS performance was tested in situ within a calibration study in the treated effluent of a municipal wastewater treatment plant and in a verification study in the raw municipal wastewater influent. HPS sampled integratively for up to 14 days in the effluent, and 8 days in the influent. Sampling rates (Rs) were derived for 44 pharmaceuticals and personal care products, 3 perfluoroalkyl substances, 2 anticorrosives, and 21 pesticides and metabolites, ranging from 6 to 132 mL d-1. Robustness and repeatability of HPS deteriorated after exposures longer than 14 days due to microbial and physical damage of the diffusive agarose layer. In situ Rs values for the HPS can be applied to estimate the aqueous concentration of the calibrated polar organic compounds in wastewater within an uncertainty factor of four. When accepting this level of accuracy, the HPS can be applied for monitoring trends of organic micropollutants in wastewater.
Collapse
Affiliation(s)
- Pavla Fialová
- RECETOX, Faculty of Science, Masaryk University, Kotlarska 2, 61137 Brno, Czech Republic
| | - Roman Grabic
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Kateřina Grabicová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Petra Nováková
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Helena Švecová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Sarit Kaserzon
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Kristie Thompson
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Branislav Vrana
- RECETOX, Faculty of Science, Masaryk University, Kotlarska 2, 61137 Brno, Czech Republic.
| |
Collapse
|
6
|
Wang P, Challis JK, He ZX, Wong CS, Zeng EY. Effects of biofouling on the uptake of perfluorinated alkyl acids by organic-diffusive gradients in thin films passive samplers. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2022; 24:242-251. [PMID: 35015011 DOI: 10.1039/d1em00436k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
While organic-diffusive gradients in thin films (o-DGT) passive samplers have been used to assess organic contaminants in water, the effects of biofouling on accurate analyte quantification by o-DGT are poorly understood. We evaluated the effects of biofouling on the uptake of six common perfluoroalkyl substances (PFAS) using a previously developed polyacrylamide-WAX (weak anion exchange) o-DGT without a filter membrane. Linear uptake (R2 > 0.91) over 21 days was observed in fouled samplers. The measured sampling rates (Rs) and accumulated masses of PFAS in pre-fouled o-DGT were significantly lower (p < 0.05, 20-39% relative error) than in control-fouled samplers. However, compared to clean o-DGT (no biofouling), the Rs of most PFAS in control-fouled samplers (i.e., those with clean diffusive and binding gels initially) were not affected by biofouling. Under flowing (∼5.8 cm s-1) and static conditions, the measured diffusive boundary layer (DBL) thicknesses for clean o-DGT were 0.016 and 0.082 cm, respectively, whereas the effective in situ biofilm thicknesses for fouled o-DGT were 0.018 and 0.14 cm, respectively. These results suggest that biofilm growth does not have significant effects on target PFAS sampling by o-DGT under typical flowing conditions (≥2 cm s-1). However, rapid surface growth of biofilm on o-DGT deployed in quiescent waters over long periods of time may exacerbate the adverse effects of biofilms, necessitating the estimation of biofilm thickness in situ. This study provides new insights for evaluating the capability of o-DGT samplers when biofilm growth can be significant.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Jonathan K Challis
- Toxicology Centre, University of Saskatchewan, Saskatoon, SK S7N 5B3, Canada
| | - Zi-Xuan He
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Charles S Wong
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
- Southern California Coastal Water Research Project Authority, Costa Mesa CA 92626, USA
| | - Eddy Y Zeng
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| |
Collapse
|
7
|
Ji X, Challis JK, Brinkmann M. A critical review of diffusive gradients in thin films technique for measuring organic pollutants: Potential limitations, application to solid phases, and combination with bioassays. CHEMOSPHERE 2022; 287:132352. [PMID: 34826958 DOI: 10.1016/j.chemosphere.2021.132352] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/20/2021] [Accepted: 09/22/2021] [Indexed: 06/13/2023]
Abstract
Diffusive gradient in thin films (DGT) for organics has received considerable attention for studying the chemical dynamics of various organic pollutants in the environment. This review investigates current limitations of DGT for organics and identifies several research gaps for future studies. The application of a protective outer filter membrane has been recommended for most DGT applications, however, important questions regarding longer lag times due to significant interaction or adsorption of specific groups of compounds on the outer membrane remain. A modified DGT configuration has been developed that uses the diffusive gel as the outer membrane without the use of an extra filter membrane, however use of this configuration, while largely successful, remains limited. Biofouling has been a concern when using DGT for metals; however, effect on the performance of DGT for organics needs to be systemically studied. Storage stability of compounds on intact DGT samplers has been assessed in select studies and that data is synthesized here. DGT has been used to describe the kinetic desorption of antibiotics from soils and biosolids based on the soil/biosolid physical-chemical characteristics, yet applications remain limited and requires further research before wide-scale adoption is recommended. Finally, DGT for organics has been rarely, albeit successfully, combined with bioassays as well as in vivo bioaccumulation studies in zebrafish. Studies using DGT combined with bioassays to predict the adverse effects of environmental mixtures on aquatic or terrestrial biota are discussed here and should be considered for future research.
Collapse
Affiliation(s)
- Xiaowen Ji
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Canada; Global Institute for Water Security, University of Saskatchewan, Saskatoon, Canada
| | | | - Markus Brinkmann
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Canada; Global Institute for Water Security, University of Saskatchewan, Saskatoon, Canada; Toxicology Centre, University of Saskatchewan, Saskatoon, Canada; Centre for Hydrology, University of Saskatchewan, Saskatoon, Canada.
| |
Collapse
|
8
|
Feng Z, Zhang W, Sun T. Effects of seasonal biofouling on diffusion coefficients through filter membranes with different hydrophilicities in natural waters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 794:148536. [PMID: 34225148 DOI: 10.1016/j.scitotenv.2021.148536] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 06/14/2021] [Accepted: 06/14/2021] [Indexed: 06/13/2023]
Abstract
Biofouling is a major issue for the diffusive gradients in thin films (DGT) passive samplers during long-term deployment. Although biofilms have a negative effect on DGT samplers, the effects of seasonal biofilms on the flux of targets through different membranes are poorly understood. Herein, we evaluated the relationship between the biofilm growth and diffusion coefficients' decline rate through two membranes with different hydrophilicities during the four seasons in natural waters. Cu2+ and tetracycline were selected as the model metal and organic contaminant, respectively. Rapid biofilm growth on the membrane surface was observed, and the fouling growth rate increased in the order: winter < spring < autumn < summer. Biofouling had a negative effect on the diffusion coefficients of Cu2+ and tetracycline. Generally, the decreasing tendency of diffusion coefficients agreed with the increasing tendency of the fouling growth rate. Biofilms in a lag phase with little bacterial colonies had insignificant effect on the diffusion coefficients. After 30 days, the decline ratios of diffusion coefficients were in the range of 38.14%-53.05%, 69.63%-83.19%, 51.57-68.42%, and 19.43-35.84%, respectively, during the spring, summer, autumn and winter. The flux through the membrane with higher hydrophilicity was greater. Both the hydrophilicity of membrane and structure of target analytes had important effects on the diffusion coefficients through biofouled membranes. Owing to similar physical and chemical characteristics, there was insignificant difference in diffusion coefficients decline trend between the Yalu River water and Hunhe River water in the summer.
Collapse
Affiliation(s)
- Zhongmin Feng
- College of Sciences, Northeastern University, Shenyang, Liaoning 110819, China
| | - Wenya Zhang
- College of Sciences, Northeastern University, Shenyang, Liaoning 110819, China
| | - Ting Sun
- College of Sciences, Northeastern University, Shenyang, Liaoning 110819, China.
| |
Collapse
|
9
|
González-Gaya B, Lopez-Herguedas N, Bilbao D, Mijangos L, Iker AM, Etxebarria N, Irazola M, Prieto A, Olivares M, Zuloaga O. Suspect and non-target screening: the last frontier in environmental analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1876-1904. [PMID: 33913946 DOI: 10.1039/d1ay00111f] [Citation(s) in RCA: 37] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Suspect and non-target screening (SNTS) techniques are arising as new analytical strategies useful to disentangle the environmental occurrence of the thousands of exogenous chemicals present in our ecosystems. The unbiased discovery of the wide number of substances present over environmental analysis needs to find a consensus with powerful technical and computational requirements, as well as with the time-consuming unequivocal identification of discovered analytes. Within these boundaries, the potential applications of SNTS include the studies of environmental pollution in aquatic, atmospheric, solid and biological samples, the assessment of new compounds, transformation products and metabolites, contaminant prioritization, bioremediation or soil/water treatment evaluation, and retrospective data analysis, among many others. In this review, we evaluate the state of the art of SNTS techniques going over the normalized workflow from sampling and sample treatment to instrumental analysis, data processing and a brief review of the more recent applications of SNTS in environmental occurrence and exposure to xenobiotics. The main issues related to harmonization and knowledge gaps are critically evaluated and the challenges of their implementation are assessed in order to ensure a proper use of these promising techniques in the near future.
Collapse
Affiliation(s)
- B González-Gaya
- Department of Analytical Chemistry, University of the Basque Country (UPV/EHU), 48940 Leioa, Basque Country, Spain.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Wang R, Biles E, Li Y, Juergens MD, Bowes MJ, Jones KC, Zhang H. In Situ Catchment Scale Sampling of Emerging Contaminants Using Diffusive Gradients in Thin Films (DGT) and Traditional Grab Sampling: A Case Study of the River Thames, UK. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:11155-11164. [PMID: 32797751 DOI: 10.1021/acs.est.0c01584] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The in situ passive sampling technique, diffusive gradients in thin films (DGT), confronts many of the challenges associated with current sampling methods used for emerging contaminants (ECs) in aquatic systems. This study compared DGT and grab sampling for their suitability to screen and monitor ECs at the catchment scale in the River Thames system (U.K.) and explored their sources and environmental fate. The ubiquitous presence of endocrine disrupting chemicals, parabens, and their metabolites is of concern. This study is the first to report organophosphate esters (OPEs) in the study area. TEP (summer 13-160 and winter 18-46, ng/L) and TCPP (summer 242-4282 and winter 215-854, ng/L) were the main OPEs. For chemicals which were relatively stable in the rivers, DGT and grab sampling were in good agreement. For chemicals which showed high variation in water bodies, DGT provided a better integral of loadings and exposure than grab sampling. DGT was not as sensitive as grab sampling under the procedures employed here, but there are several options to improve it to give comparable/better performance. DGT samples require shorter preparation time for analysis in the laboratory than grab samples. Overall, DGT can be a powerful tool to characterize ECs throughout a large dynamic water system.
Collapse
Affiliation(s)
- Runmei Wang
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | - Emma Biles
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | - Yanying Li
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | | | - Michael J Bowes
- Centre for Ecology and Hydrology, Wallingford, Oxon OX10 8BB, U.K
| | - Kevin C Jones
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| |
Collapse
|