1
|
Chremos A, Mussel M, Douglas JF, Horkay F. Ion Partition in Polyelectrolyte Gels and Nanogels. Gels 2023; 9:881. [PMID: 37998971 PMCID: PMC10670699 DOI: 10.3390/gels9110881] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 11/02/2023] [Accepted: 11/04/2023] [Indexed: 11/25/2023] Open
Abstract
Polyelectrolyte gels provide a load-bearing structural framework for many macroscopic biological tissues, along with the organelles within the cells composing tissues and the extracellular matrices linking the cells at a larger length scale than the cells. In addition, they also provide a medium for the selective transportation and sequestration of ions and molecules necessary for life. Motivated by these diverse problems, we focus on modeling ion partitioning in polyelectrolyte gels immersed in a solution with a single type of ionic valence, i.e., monovalent or divalent salts. Specifically, we investigate the distribution of ions inside the gel structure and compare it with the bulk, i.e., away from the gel structure. In this first exploratory study, we neglect solvation effects in our gel by modeling the gels without an explicit solvent description, with the understanding that such an approach may be inadequate for describing ion partitioning in real polyelectrolyte gels. We see that this type of model is nonetheless a natural reference point for considering gels with solvation. Based on our idealized polymer network model without explicit solvent, we find that the ion partition coefficients scale with the salt concentration, and the ion partition coefficient for divalent ions is higher than for monovalent ions over a wide range of Bjerrum length (lB) values. For gels having both monovalent and divalent salts, we find that divalent ions exhibit higher ion partition coefficients than monovalent salt for low divalent salt concentrations and low lB. However, we also find evidence that the neglect of an explicit solvent, and thus solvation, provides an inadequate description when compared to experimental observations. Thus, in future work, we must consider both ion and polymer solvation to obtain a more realistic description of ion partitioning in polyelectrolyte gels.
Collapse
Affiliation(s)
- Alexandros Chremos
- Section on Quantitative Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD 20892, USA
| | - Matan Mussel
- Department of Physics, University of Haifa, Haifa 3103301, Israel
| | - Jack F. Douglas
- Materials Science and Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| | - Ferenc Horkay
- Section on Quantitative Imaging and Tissue Sciences, Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD 20892, USA
| |
Collapse
|
2
|
Chen X, Zhang Y, Yuan Q, Li M, Bian Y, Su D, Gao X. Bioorthogonal chemistry in metal clusters: a general strategy for the construction of multifunctional probes for bioimaging in living cells and in vivo. J Mater Chem B 2021; 9:6614-6622. [PMID: 34378627 DOI: 10.1039/d1tb00836f] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Multifunctional bioimaging probes based on metal clusters have multiple characteristics of metal clusters and functional conjugates, and their development has broad application prospects in the fields of biomedical imaging and tumor diagnosis. However, current bioconjugation methods on metal clusters are time-consuming and have low reaction efficiency, which hinders the construction of bioimaging probes with multifunctional components. Here, we report a concise and promising design strategy to realize the simple and efficient introduction of functional conjugates through bioorthogonal reactions based on azido-functionalized metal clusters. Based on this strategy, taking the probe FA-CuC@BSA-Cy5 as an example, we demonstrated the design of a copper cluster-based multifunctional near-infrared (NIR) fluorescent probe and its real-time imaging application in vivo. Through the strain-promoted azide-alkyne cycloaddition (SPAAC) reaction, the tumor-specific targeting ligand folic acid (FA) and fluorophore (Cy5) can be chemically conjugated to azido-functionalized CuC@BSA-N3 quickly and efficiently under biocompatible conditions. The prepared probe showed numerous advantages of metal clusters, including good stability, ultra-small particle size and low toxicity and rapid renal clearance. At the same time, FA-modified FA-CuC@BSA-Cy5 can specifically target KB cells with high FR expression, and in vivo fluorescence imaging shows higher tumor accumulation. The construction of the azido functional metal cluster platform can be extended to various metal clusters with functional probes and prodrugs, thereby providing more promising candidates for future medical diagnoses.
Collapse
Affiliation(s)
- Xueqian Chen
- Department of Chemistry and Biology, Faculty of Environment and Life Science, Beijing University of Technology, Beijing, 100124, P. R. China.
| | | | | | | | | | | | | |
Collapse
|
3
|
Mussel M, Basser PJ, Horkay F. Ion-Induced Volume Transition in Gels and Its Role in Biology. Gels 2021; 7:20. [PMID: 33670826 PMCID: PMC8005988 DOI: 10.3390/gels7010020] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 02/09/2021] [Accepted: 02/11/2021] [Indexed: 12/12/2022] Open
Abstract
Incremental changes in ionic composition, solvent quality, and temperature can lead to reversible and abrupt structural changes in many synthetic and biopolymer systems. In the biological milieu, this nonlinear response is believed to play an important functional role in various biological systems, including DNA condensation, cell secretion, water flow in xylem of plants, cell resting potential, and formation of membraneless organelles. While these systems are markedly different from one another, a physicochemical framework that treats them as polyelectrolytes, provides a means to interpret experimental results and make in silico predictions. This article summarizes experimental results made on ion-induced volume phase transition in a polyelectrolyte model gel (sodium polyacrylate) and observations on the above-mentioned biological systems indicating the existence of a steep response.
Collapse
Affiliation(s)
- Matan Mussel
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD 20892, USA;
| | | | - Ferenc Horkay
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD 20892, USA;
| |
Collapse
|
4
|
Chimisso V, Conti S, Kong P, Fodor C, Meier WP. Metal cation responsive anionic microgels: behaviour towards biologically relevant divalent and trivalent ions. SOFT MATTER 2021; 17:715-723. [PMID: 33220668 DOI: 10.1039/d0sm01458c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Anionic poly(vinylcaprolactam-co-itaconicacid-co-dimethylitaconate) microgels were synthesized via dispersion polymerization and their responsiveness towards cations, namely Mg2+, Sr2+, Cu2+ and Fe3+, was investigated. The itaconic moieties chelate the metal ions which act as a crosslinker and decrease the electrostatic repulsion within the network, leading to a decrease in the gel size. The responsiveness towards the metal ion concentration has been studied via dynamic light scattering (DLS) and the number of ions bonded within the network has been quantified with ion chromatography. Through the protonation of the carboxylate groups in the gel network, their interaction with the cations is significantly lowered, and the metals are consequently released back in solution. The number of ions released was assessed also via ion chromatography for all four ions, whilst Mg2+ was also used as a model ion to display the reversibility of the system. The microgels can bond and release divalent cations over multiple cycles without undergoing any loss of functionality. Moreover, these gels also selectively entrap Fe3+ with respect to the remaining divalent cations, opening the possibility of using the proposed gels in the digestive tract as biocompatible chelating agents to fight iron overaccumulation.
Collapse
Affiliation(s)
- Vittoria Chimisso
- Department of Chemistry, University of Basel, Mattenstrasse 24/a, 4002, Basel, Switzerland.
| | - Simona Conti
- Department of Chemistry, University of Basel, Mattenstrasse 24/a, 4002, Basel, Switzerland.
| | - Phally Kong
- Department of Chemistry, University of Basel, Mattenstrasse 24/a, 4002, Basel, Switzerland.
| | - Csaba Fodor
- Department of Chemistry, University of Basel, Mattenstrasse 24/a, 4002, Basel, Switzerland.
| | - Wolfgang P Meier
- Department of Chemistry, University of Basel, Mattenstrasse 24/a, 4002, Basel, Switzerland.
| |
Collapse
|
5
|
Han Y, Zhao X, Liu Y, Li Y, Chen Q. Structure and phase behavior of poly(acrylic acid)-ferric ion complex aqueous solutions. SOFT MATTER 2020; 16:10750-10758. [PMID: 33107898 DOI: 10.1039/d0sm01461c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In this study, we investigate the conformational evolution and phase behavior of poly(acrylic acid) (PAA) solution upon the introduction of ferric ions through a combination of small angle X-ray scattering (SAXS), turbidity, zeta-potential and pH measurements. Salt-free PAA aqueous solution is a weak polyelectrolyte solution. The introduced ferric ion can coordinate with the carboxylic acid groups, yielding H+ ions to lower the pH value. We find two transitions with increasing concentration of the ferric ions: a polyelectrolyte to apparent good solution transition characterized by the disappearance of the polyelectrolyte peak in the X-ray scattering, and a phase separation characterized by a sharp increase of the turbidity. Detailed analyses of pH and zeta-potential reveal the molecular details of the three regions. Namely, (1) the polyelectrolyte region locates at log[H+] (= -pH) ≫ log(3[Fe3+]), where the H+ ions are mainly contributed from the dissociation of carboxylic acid, and the polymer chains are negatively charged, (2) the good solution region locates at log[H+] ∼ log(3[Fe3+]), where the H+ ions are mainly yielded from coordination between COO- and Fe3+, and polymer chains are nearly neutralized, and (3) the phase separation locates at log[H+] ≪ log(3[Fe3+]), where the Fe3+ ions are not fully coordinated, and charge inversion occurs. The phase separation occurs when the chains are densely and tightly coordinated with Fe3+ ions.
Collapse
Affiliation(s)
- Yingchun Han
- State Key Laboratory of Polymer Physics and Chemistry & Key Laboratory of High-Perfomance Synthetic Rubber and its Composite Materials, Changchun Institute of Applied Chemistry, Chinese Acadamy of Science, Changchun 130022, Jilin, China.
| | | | | | | | | |
Collapse
|
6
|
Dušek K, Dušková-Smrčková M. Volume Phase Transition in Gels: Its Discovery and Development. Gels 2020; 6:E22. [PMID: 32752072 PMCID: PMC7557368 DOI: 10.3390/gels6030022] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 07/22/2020] [Accepted: 07/27/2020] [Indexed: 11/17/2022] Open
Abstract
The history of volume phase transition of responsive gels from its theoretical prediction to experimental discovery was described and the major role of mixing Gibbs energy function in theoretical models was stressed. For detailed analysis and fine tuning of the volume phase transition, the generalized Flory-Huggins model with concentration and temperature dependent interaction function coupled with Maxwell construction as a tool is very suitable. Application of expansive stresses can uncover the potential of various swelling gels for volume phase transition. Experimentally, the abrupt, equilibrium-controlled phase transition is often hard to achieve due to passage of gel through states of mechanical instability and slow relaxation processes in macroscopic objects.
Collapse
Affiliation(s)
| | - Miroslava Dušková-Smrčková
- Institute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského náměstí 2, 162 06 Prague 6, Czech Republic;
| |
Collapse
|