1
|
Yuan P, Chen M, Lu X, Yang H, Wang L, Bai T, Zhou W, Liu T, Yu S. Application of advanced surface modification techniques in titanium-based implants: latest strategies for enhanced antibacterial properties and osseointegration. J Mater Chem B 2024; 12:10516-10549. [PMID: 39311411 DOI: 10.1039/d4tb01714e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Titanium-based implants, renowned for their excellent mechanical properties, corrosion resistance, and biocompatibility, have found widespread application as premier implant materials in the medical field. However, as bioinert materials, they often face challenges such as implant failure caused by bacterial infections and inadequate osseointegration post-implantation. Thus, to address these issues, researchers have developed various surface modification techniques to enhance the surface properties and bioactivity of titanium-based implants. This review aims to outline several key surface modification methods for titanium-based implants, including acid etching, sol-gel method, chemical vapor deposition, electrochemical techniques, layer-by-layer self-assembly, and chemical grafting. It briefly summarizes the advantages, limitations, and potential applications of these technologies, presenting readers with a comprehensive perspective on the latest advances and trends in the surface modification of titanium-based implants.
Collapse
Affiliation(s)
- Pingyun Yuan
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Mi Chen
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Xiaotong Lu
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Hui Yang
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Lan Wang
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Tian Bai
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Wenhao Zhou
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| | - Tao Liu
- Precision Medical Institute, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, China.
| | - Sen Yu
- Shaanxi Key Laboratory of Biomedical Metallic Materials, Northwest Institute for Non-ferrous Metal Research, Xi'an, 710016, China.
| |
Collapse
|
2
|
Zhang D, Liu H, Xue X, Liu F, Wu J, Peng F, Wang D, Pan H, Li M. Enhancing immune modulation and bone regeneration on titanium implants by alleviating the hypoxic microenvironment and releasing bioactive ions. Colloids Surf B Biointerfaces 2024; 236:113805. [PMID: 38422666 DOI: 10.1016/j.colsurfb.2024.113805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Revised: 02/08/2024] [Accepted: 02/16/2024] [Indexed: 03/02/2024]
Abstract
Bone implantation inevitably causes damage to surrounding vasculature, resulting in a hypoxic microenvironment that hinders bone regeneration. Although titanium (Ti)-based devices are widely used as bone implants, their inherent bioinert surface leads to poor osteointegration. Herein, a strontium peroxide (SrO2)-decorated Ti implant, Ti_P@SrO2, was constructed through coating with poly-L-lactic acid (PLLA) to alleviate the hypoxic microenvironment and transform the bioinert surface of the implant into a bioactive surface. PLLA degradation resulted in an acidic microenvironment and the release of SrO2 nanoparticles. The acidic microenvironment then accelerated the decomposition of SrO2, resulting in the release of O2 and Sr ions. O2 released from Ti_P@SrO2 can alleviate the hypoxic microenvironment, thus enhancing cell proliferation in an O2-insufficient microenvironment. Furthermore, under hypoxic and normal microenvironments, Ti_P@SrO2 enhanced alkaline phosphatase activity and bone-related gene expression in C3H10T1/2 cells with the continuous release of Sr ions. Meanwhile, Ti_P@SrO2 suppressed M1 polarization and promoted M2 polarization of bone marrow-derived monocytes under hypoxic and normal conditions. Furthermore, in a rat implantation model, the implant enhanced new bone formation and improved osteointegration after modification with SrO2. In summary, the newly designed O2- and Sr ion-releasing Ti implants are promising for applications in bone defects.
Collapse
Affiliation(s)
- Dongdong Zhang
- Shenzhen Key Laboratory for Innovative Technology in Orthopedic Trauma, Department of Orthopaedics and Traumatology, The University of Hong Kong-Shenzhen Hospital, Shenzhen 518053, PR China
| | - Han Liu
- Medical Research Institute, Department of Orthopedics, Guangdong Provincial People's Hospital, (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, PR China; Hebei Key Laboratory of Biomaterials and Smart Theranostics, School of Materials Science and Engineering, Hebei University of Technology, Tianjin 300130, PR China
| | - Xiaodong Xue
- Hebei Key Laboratory of Biomaterials and Smart Theranostics, School of Materials Science and Engineering, Hebei University of Technology, Tianjin 300130, PR China
| | - Feihong Liu
- Shenzhen Key Laboratory for Innovative Technology in Orthopedic Trauma, Department of Orthopaedics and Traumatology, The University of Hong Kong-Shenzhen Hospital, Shenzhen 518053, PR China
| | - Jun Wu
- Shenzhen Key Laboratory for Innovative Technology in Orthopedic Trauma, Department of Orthopaedics and Traumatology, The University of Hong Kong-Shenzhen Hospital, Shenzhen 518053, PR China
| | - Feng Peng
- Medical Research Institute, Department of Orthopedics, Guangdong Provincial People's Hospital, (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, PR China
| | - Donghui Wang
- Hebei Key Laboratory of Biomaterials and Smart Theranostics, School of Materials Science and Engineering, Hebei University of Technology, Tianjin 300130, PR China.
| | - Haobo Pan
- Center for Human Tissues and Organs Degeneration, Shenzhen Institutes of Advanced Technology, Chinese Academy of Science, Shenzhen 518055, PR China.
| | - Mei Li
- Medical Research Institute, Department of Orthopedics, Guangdong Provincial People's Hospital, (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, PR China.
| |
Collapse
|
3
|
Schafer S, Swain T, Parra M, Slavin BV, Mirsky NA, Nayak VV, Witek L, Coelho PG. Nonthermal Atmospheric Pressure Plasma Treatment of Endosteal Implants for Osseointegration and Antimicrobial Efficacy: A Comprehensive Review. Bioengineering (Basel) 2024; 11:320. [PMID: 38671741 PMCID: PMC11048570 DOI: 10.3390/bioengineering11040320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 03/18/2024] [Accepted: 03/22/2024] [Indexed: 04/28/2024] Open
Abstract
The energy state of endosteal implants is dependent on the material, manufacturing technique, cleaning procedure, sterilization method, and surgical manipulation. An implant surface carrying a positive charge renders hydrophilic properties, thereby facilitating the absorption of vital plasma proteins crucial for osteogenic interactions. Techniques to control the surface charge involve processes like oxidation, chemical and topographical adjustments as well as the application of nonthermal plasma (NTP) treatment. NTP at atmospheric pressure and at room temperature can induce chemical and/or physical reactions that enhance wettability through surface energy changes. NTP has thus been used to modify the oxide layer of endosteal implants that interface with adjacent tissue cells and proteins. Results have indicated that if applied prior to implantation, NTP strengthens the interaction with surrounding hard tissue structures during the critical phases of early healing, thereby promoting rapid bone formation. Also, during this time period, NTP has been found to result in enhanced biomechanical fixation. As such, the application of NTP may serve as a practical and reliable method to improve healing outcomes. This review aims to provide an in-depth exploration of the parameters to be considered in the application of NTP on endosteal implants. In addition, the short- and long-term effects of NTP on osseointegration are addressed, as well as recent advances in the utilization of NTP in the treatment of periodontal disease.
Collapse
Affiliation(s)
- Sogand Schafer
- Division of Plastic, Reconstructive and Oral Surgery, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA
| | - Tina Swain
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Marcelo Parra
- Center of Excellence in Morphological and Surgical Studies (CEMyQ), Faculty of Medicine, Universidad de la Frontera, Temuco 4811230, Chile
- Department of Comprehensive Adult Dentistry, Faculty of Dentistry, Universidad de la Frontera, Temuco 4811230, Chile
| | - Blaire V. Slavin
- University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | | | - Vasudev Vivekanand Nayak
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Lukasz Witek
- Biomaterials Division, New York University Dentistry, New York, NY 10010, USA
- Department of Biomedical Engineering, New York University Tandon School of Engineering, Brooklyn, NY 11201, USA
- Hansjörg Wyss Department of Plastic Surgery, New York University Grossman School of Medicine, New York, NY 10016, USA
| | - Paulo G. Coelho
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
- DeWitt Daughtry Family Department of Surgery, Division of Plastic Surgery, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| |
Collapse
|
4
|
Sun XD, Liu TT, Wang QQ, Zhang J, Cao MS. Surface Modification and Functionalities for Titanium Dental Implants. ACS Biomater Sci Eng 2023; 9:4442-4461. [PMID: 37523241 DOI: 10.1021/acsbiomaterials.3c00183] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Dental implants have become the mainstream strategy for oral restoration, and implant materials are the most important research hot spot in this field. So far, Ti implants dominate all kinds of implants. The surface properties of the Ti implant play decisive roles in osseointegration and antibacterial performance. Surface modifications can significantly change the surface micro/nanotopography and composition of Ti implants, which will effectively improve their hydrophilicity, mechanical properties, osseointegration performance, antibacterial performance, etc. These optimizations will thus improve implant success and service life. In this paper, the latest surface modification techniques of Ti dental implants are systematically and comprehensively reviewed. The various biomedical functionalities of surface modifications are discussed in-depth. Finally, a profound comment on the challenges and opportunities of this frontier is proposed, and the most promising directions for the future were explored.
Collapse
Affiliation(s)
- Xiao-Di Sun
- Tianjin Stomatological Hospital, Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction, Tianjin 300041, China
| | - Ting-Ting Liu
- School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Qiang-Qiang Wang
- School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Jian Zhang
- Tianjin Stomatological Hospital, Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction, Tianjin 300041, China
| | - Mao-Sheng Cao
- School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
5
|
Heydariyan Z, Soofivand F, Dawi EA, Abd Al-Kahdum SA, Hameed NM, Salavati-Niasari M. A comprehensive review: Different approaches for encountering of bacterial infection of dental implants and improving their properties. J Drug Deliv Sci Technol 2023. [DOI: 10.1016/j.jddst.2023.104401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
6
|
Electrochemical and biological characterization of Ti-Nb-Zr-Si alloy for orthopedic applications. Sci Rep 2023; 13:2312. [PMID: 36759646 PMCID: PMC9911760 DOI: 10.1038/s41598-023-29553-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 02/06/2023] [Indexed: 02/11/2023] Open
Abstract
The performance of current biomedical titanium alloys is limited by inflammatory and severe inflammatory conditions after implantation. In this study, a novel Ti-Nb-Zr-Si (TNZS) alloy was developed and compared with commercially pure titanium, and Ti-6Al-4V alloy. Electrochemical parameters of specimens were monitored during 1 h and 12 h immersion in phosphate buffered saline (PBS) as a normal, PBS/hydrogen peroxide (H2O2) as an inflammatory, and PBS/H2O2/albumin/lactate as a severe inflammatory media. The results showed an effect of the H2O2 in inflammatory condition and the synergistic behavior of H2O2, albumin, and lactate in severe inflammatory condition towards decreasing the corrosion resistance of titanium biomaterials. Electrochemical tests revealed a superior corrosion resistance of the TNZS in all conditions due to the presence of silicide phases. The developed TNZS was tested for subsequent cell culture investigation to understand its biocompatibility nature. It exhibited favorable cell-materials interactions in vitro compared with Ti-6Al-4V. The results suggest that TNZS alloy might be a competitive biomaterial for orthopedic applications.
Collapse
|
7
|
Hu Y, Duan J, Yang X, Zhang C, Fu W. Wettability and biological responses of titanium surface's biomimetic hexagonal microstructure. J Biomater Appl 2023; 37:1112-1123. [PMID: 36154504 DOI: 10.1177/08853282221121883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this research, an experiment was conducted on how the surface wettability and biocompatibility of staplers' titanium nails impact the healing of gastrointestinal tissue. Firstly, the bionic hexagonal structure was prepared on the surface of Ti metal by laser processing technology, and the laser textured titanium samples were observed by scanning electron microscope. Then, the liquid-solid contact angle-measuring instrument was used to characterize the wettability of titanium samples. Finally, cells were cultured on the surface of different titanium samples, CCK8 assay and qRT-PCR were carried out to investigate cell adhesion and collagen secretion on the surface of different samples. The results showed that the bionic hexagonal surface increased the surface roughness, reduced the liquid-solid contact angle, and promoted the adhesion and collagen secretion of fibroblasts. The increased wettability provided a better growth environment for cell growth. Microtexture is an important factor affecting the behavior of cells and its size parameters regulate cell gene expression, which is worthy of further study.
Collapse
Affiliation(s)
- Yahui Hu
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, National Demonstration Center for Experimental Mechanical and Electrical Engineering Education,66346Tianjin University of Technology, Tianjin, China
| | - Junyu Duan
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, National Demonstration Center for Experimental Mechanical and Electrical Engineering Education,66346Tianjin University of Technology, Tianjin, China
| | - Xiaoyang Yang
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, National Demonstration Center for Experimental Mechanical and Electrical Engineering Education,66346Tianjin University of Technology, Tianjin, China
| | - Chunqiu Zhang
- Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, National Demonstration Center for Experimental Mechanical and Electrical Engineering Education,66346Tianjin University of Technology, Tianjin, China
| | - Weihua Fu
- Department of General Surgery, 12610Tianjin Medical University General Hospital, Tianjin, China
| |
Collapse
|
8
|
He F, Li J, Wang Y, Li Z, Wang L, Li Y, Chen H, Wang C, Liu B, Ma P, Dong G, Zhou P. Design of Cefotaxime Sodium-Loaded Polydopamine Coatings with Controlled Surface Roughness for Titanium Implants. ACS Biomater Sci Eng 2022; 8:4751-4763. [PMID: 36191062 DOI: 10.1021/acsbiomaterials.2c00702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The success rate of dental implants is limited by peri-implant infection and insufficient osseointegration. Therefore, reducing the occurrence of peri-implantitis and promoting osseointegration are in demand. A roughened surface has commonly been applied to improve the osseointegration of implants, but it will accelerate the attachment of bacteria. We have developed novel antibiotic-decorated titanium (Ti) surfaces by the immobilization of dopamine and cefotaxime sodium (CS) simultaneously. Moreover, the surface roughness of the polydopamine (PDA)/CS coating was controlled by the changes in polymerization times as determined by atomic force microscopy. Then, all antibiotic-grafted Ti surfaces could effectively prevent the adhesion and proliferation of both Escherichia coli and Streptococcus mutans in comparison to the pristine control. For the culture and osteogenic differentiation of human umbilical mesenchymal stem cells (hUMSCs) on the substrate surface, PDA/CS coating with polymerization times less than 30 min showed acceptable biocompatibility, but the upregulation of marker genes and proteins was detected when the polymerization time was more than 30 min. Moreover, the best calcium deposition results were found in the 30 min PDA/CS group with or without the addition of osteogenic factors. Therefore, our PDA/CS coating with a polymerization time of 30 min holds great potential to design dental implants with dual bacteriostatic and osteogenic properties.
Collapse
Affiliation(s)
- Fei He
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China.,Key Laboratory of Mechanics on Disaster and Environment in Western China, Ministry of Education, College of Civil Engineering and Mechanics, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Jing Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Yixi Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Zhipeng Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Lu Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Yuchen Li
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Huiling Chen
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Chenggang Wang
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Bin Liu
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Peng Ma
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Genxi Dong
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China
| | - Ping Zhou
- School and Hospital of Stomatology, Lanzhou University, No. 222 Tianshui South Road, Chengguan District, Lanzhou 730000, Gansu, P. R. China.,Department of Orthopedics, Lanzhou University Second Hospital, No. 82 Cuiyingmen Street, Lanzhou 730030, Gansu, P. R. China
| |
Collapse
|
9
|
Prosolov KA, Lastovka VV, Khimich MA, Chebodaeva VV, Khlusov IA, Sharkeev YP. RF Magnetron Sputtering of Substituted Hydroxyapatite for Deposition of Biocoatings. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6828. [PMID: 36234169 PMCID: PMC9573009 DOI: 10.3390/ma15196828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
Functionalization of titanium (Ti)-based alloy implant surfaces by deposition of calcium phosphates (CaP) has been widely recognized. Substituted hydroxyapatites (HA) allow the coating properties to be tailored based on the use of different Ca substitutes. The formation of antibacterial CaP coatings with the incorporation of Zn or Cu by an RF magnetron sputtering is proposed. The influence of RF magnetron targets elemental composition and structure in the case of Zn-HA and Cu-HA, and the influence of substrate's grain size, the substrate's temperature during the deposition, and post-deposition heat treatment (HT) on the resulting coatings are represented. Sintering the targets at 1150 °C resulted in a noticeable structural change with an increase in cell volume and lattice parameters for substituted HA. The deposition rate of Cu-HA and Zn-HA was notably higher compared to stochiometric HA (10.5 and 10) nm/min vs. 9 ± 0.5 nm/min, respectively. At the substrate temperature below 100 °C, all deposited coatings were found to be amorphous with an atomic short-range order corresponding to the {300} plane of crystalline HA. All deposited coatings were found to be hyper-stochiometric with Ca/P ratios varying from 1.9 to 2.5. An increase in the substrate temperature to 200 °C resulted in the formation of equiaxed grain structure on both coarse-grained (CG) and nanostructured (NS) Ti. The use of NS Ti notably increased the scratch resistance of the deposited coatings from18 ± 1 N to 22 ± 2 N. Influence of HT in air or Ar atmosphere is also discussed. Thus, the deposition of Zn- or Cu-containing CaP is a complex process that could be fine-tuned using the obtained research results.
Collapse
Affiliation(s)
- Konstantin A. Prosolov
- Laboratory of Physics of Nanostructured Biocomposites, Institute of Strength Physics and Materials Science, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
| | - Vladimir V. Lastovka
- Laboratory of Physics of Nanostructured Biocomposites, Institute of Strength Physics and Materials Science, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
| | - Margarita A. Khimich
- Laboratory of Physics of Nanostructured Biocomposites, Institute of Strength Physics and Materials Science, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
| | - Valentina V. Chebodaeva
- Laboratory of Physics of Nanostructured Biocomposites, Institute of Strength Physics and Materials Science, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
- Laboratory of Cellular and Microfluidic Technologies, Siberian State Medical University, 634050 Tomsk, Russia
| | - Igor A. Khlusov
- Laboratory of Cellular and Microfluidic Technologies, Siberian State Medical University, 634050 Tomsk, Russia
| | - Yurii P. Sharkeev
- Laboratory of Physics of Nanostructured Biocomposites, Institute of Strength Physics and Materials Science, Siberian Branch of Russian Academy of Sciences, 634055 Tomsk, Russia
- Research School of High-Energy Physics, National Research Tomsk Polytechnic University, Lenin Avenue 30, 634050 Tomsk, Russia
| |
Collapse
|
10
|
Evaluation of Biocompatibility of 316 L Stainless Steels Coated with TiN, TiCN, and Ti-DLC Films. COATINGS 2022. [DOI: 10.3390/coatings12081073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
In this study, TiN, TiCN, and Ti-diamond-like carbon (Ti-DLC) films were coated on 316 L stainless steel (AISI 316 L) substrate surface by physical vapor deposition. The biocompatibility of the three films (TiN, TiCN, and Ti-DLC) and three metals (AISI 316 L, Ti, and Cu) was compared on the basis of the differences in the surface morphology, water contact angle measurements, CCK-8 experiment results, and flow cytometry test findings. The biocompatibility of the TiN and TiCN films is similar to that of AISI 316 L, which has good biocompatibility. However, the biocompatibility of the Ti-DLC films is relatively poor, which is mainly due to the inferior hydrophobicity and large amount of sp2 phases. The presence of TiC nanoclusters on the surface of the Ti-DLC film aggravates the inferior biocompatibility. Compared to the positive Cu control group, the Ti-DLC film had a higher cell proliferation rate and lower cell apoptosis rate. Although the Ti-DLC film inhibited cell survival to a certain extent, it did not show obvious cytotoxicity. TiN and TiCN displayed excellent performance in promoting cell proliferation and reducing cytotoxicity; thus, TiN and TiCN can be considered good orthodontic materials, whereas Ti-DLC films require further improvement.
Collapse
|
11
|
Fang K, Shen Y, Ru Yie KH, Zhou Z, Cai L, Wu S, Al-Bishari AM, Al-Baadani MA, Shen X, Ma P, Liu J. Preparation of Zirconium Hydrogen Phosphate Coatings on Sandblasted/Acid-Etched Titanium for Enhancing Its Osteoinductivity and Friction/Corrosion Resistance. Int J Nanomedicine 2022; 16:8265-8277. [PMID: 35002230 PMCID: PMC8729793 DOI: 10.2147/ijn.s337028] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 12/14/2021] [Indexed: 01/01/2023] Open
Abstract
Background Sandblasted/acid-etched titanium (SLA-Ti) implants are widely used for dental implant restoration in edentulous patients. However, the poor osteoinductivity and the large amount of Ti particles/ions released due to friction or corrosion will affect its long-term success rate. Purpose Various zirconium hydrogen phosphate (ZrP) coatings were prepared on SLA-Ti surface to enhance its friction/corrosion resistance and osteoinduction. Methods The mixture of ZrCl4 and H3PO4 was first coated on SLA-Ti and then calcined at 450°C for 5 min to form ZrP coatings. In addition to a series of physiochemical characterization such as morphology, roughness, wettability, and chemical composition, their capability of anti-friction and anti-corrosion were further evaluated by friction-wear test and by potential scanning. The viability and osteogenic differentiation of MC3T3-E1 cells on different substrates were investigated via MTT, mineralization and PCR assays. Results The characterization results showed that there were no significant changes in the morphology, roughness and wettability of ZrP-modified samples (SLA-ZrP0.5 and SLA-ZrP0.7) compared with SLA group. The results of electrochemical corrosion displayed that both SLA-ZrP0.5 and SLA-ZrP0.7 (especially the latter) had better corrosion resistance than SLA in normal saline and serum-containing medium. SLA-ZrP0.7 also exhibited the best friction resistance and great potential to enhance the spreading, proliferation and osteogenic differentiation of MC3T3-E1 cells. Conclusion We determined that SLA-ZrP0.7 had excellent comprehensive properties including anti-corrosion, anti-friction and osteoinduction, which made it have a promising clinical application in dental implant restoration.
Collapse
Affiliation(s)
- Kai Fang
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Yiding Shen
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Kendrick Hii Ru Yie
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Zixin Zhou
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Lei Cai
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Shuyi Wu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Abdullrahman M Al-Bishari
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Mohammed A Al-Baadani
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Xinkun Shen
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Pingping Ma
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| | - Jinsong Liu
- School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325000, People's Republic of China
| |
Collapse
|
12
|
Zhou W, Zhang W, Huo W, Lu J, Zeng D, Yu Z, Yu S. [Research progress on the biological properties of the surface nanocrystals of typical medical metal materials]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:303-306. [PMID: 33719237 DOI: 10.7507/1002-1892.202009084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Biomedical metal materials have always been a major biomedical material with a large and wide range of clinical use due to their excellent properties such as high strength and toughness, fatigue resistance, easy forming, and corrosion resistance. They are also the preferred implant material for hard tissues (bones and teeth that need to withstand higher loads) and interventional stents. And nano-medical metal materials have better corrosion resistance and biocompatibility. This article focuses on the changes and improvements in the properties of several typical medical metal materials surfaces after nanocrystallization, and discusses the current problems and development prospects of nano-medical metal materials.
Collapse
Affiliation(s)
- Wenhao Zhou
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China
| | - Wei Zhang
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China
| | - Wangtu Huo
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China
| | - Jinwen Lu
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China
| | - Depeng Zeng
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China
| | - Zhentao Yu
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China
| | - Sen Yu
- Shaanxi Key Laboratory of Biomedical Metal Materials, Northwest Institute for Non-Ferrous Metal Research, Xi'an Shaanxi, 710016, P.R.China;Institue of Advanced Meterials, East China Jiaotong University, Nanchang Jiangxi, 330013, P.R.China
| |
Collapse
|