1
|
Schmid W, Danstrom IA, Crespo Echevarria M, Adkinson J, Mattar L, Banks GP, Sheth SA, Watrous AJ, Heilbronner SR, Bijanki KR, Alabastri A, Bartoli E. A biophysically constrained brain connectivity model based on stimulation-evoked potentials. J Neurosci Methods 2024; 405:110106. [PMID: 38453060 PMCID: PMC11233030 DOI: 10.1016/j.jneumeth.2024.110106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 01/24/2024] [Accepted: 03/04/2024] [Indexed: 03/09/2024]
Abstract
BACKGROUND Single-pulse electrical stimulation (SPES) is an established technique used to map functional effective connectivity networks in treatment-refractory epilepsy patients undergoing intracranial-electroencephalography monitoring. While the connectivity path between stimulation and recording sites has been explored through the integration of structural connectivity, there are substantial gaps, such that new modeling approaches may advance our understanding of connectivity derived from SPES studies. NEW METHOD Using intracranial electrophysiology data recorded from a single patient undergoing stereo-electroencephalography (sEEG) evaluation, we employ an automated detection method to identify early response components, C1, from pulse-evoked potentials (PEPs) induced by SPES. C1 components were utilized for a novel topology optimization method, modeling 3D electrical conductivity to infer neural pathways from stimulation sites. Additionally, PEP features were compared with tractography metrics, and model results were analyzed with respect to anatomical features. RESULTS The proposed optimization model resolved conductivity paths with low error. Specific electrode contacts displaying high error correlated with anatomical complexities. The C1 component strongly correlated with additional PEP features and displayed stable, weak correlations with tractography measures. COMPARISON WITH EXISTING METHOD Existing methods for estimating neural signal pathways are imaging-based and thus rely on anatomical inferences. CONCLUSIONS These results demonstrate that informing topology optimization methods with human intracranial SPES data is a feasible method for generating 3D conductivity maps linking electrical pathways with functional neural ensembles. PEP-estimated effective connectivity is correlated with but distinguished from structural connectivity. Modeled conductivity resolves connectivity pathways in the absence of anatomical priors.
Collapse
Affiliation(s)
- William Schmid
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA
| | - Isabel A Danstrom
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Maria Crespo Echevarria
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Joshua Adkinson
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Layth Mattar
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Garrett P Banks
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Sameer A Sheth
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Andrew J Watrous
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Sarah R Heilbronner
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Kelly R Bijanki
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA
| | - Alessandro Alabastri
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston, TX 77005, USA.
| | - Eleonora Bartoli
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston, TX 77030, USA.
| |
Collapse
|
2
|
Yuan L, Zhao Y, Toma A, Aglieri V, Gerislioglu B, Yuan Y, Lou M, Ogundare A, Alabastri A, Nordlander P, Halas NJ. A Quasi-Bound States in the Continuum Dielectric Metasurface-Based Antenna-Reactor Photocatalyst. NANO LETTERS 2024; 24:172-179. [PMID: 38156648 DOI: 10.1021/acs.nanolett.3c03585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2024]
Abstract
Metasurfaces are a class of two-dimensional artificial resonators, creating new opportunities for strong light-matter interactions. One type of nonradiative optical metasurface that enables substantial light concentration is based on quasi-Bound States in the Continuum (quasi-BIC). Here we report the design and fabrication of a quasi-BIC dielectric metasurface that serves as an optical frequency antenna for photocatalysis. By depositing Ni nanoparticle reactors onto the metasurface, we create an antenna-reactor photocatalyst, where the virtually lossless metasurface funnels light to drive a chemical reaction. This quasi-BIC-Ni antenna-reactor drives H2 dissociation under resonant illumination, showing strong polarization, wavelength, and optical power dependencies. Both E-field-induced electronic and photothermal heating effects drive the reaction, supported by load-dependent reactivity studies and our theoretical model. This study unlocks new opportunities for photocatalysis that employ dielectric metasurfaces for light harvesting in an antenna-reactor format.
Collapse
Affiliation(s)
- Lin Yuan
- Department of Chemistry, Rice University, Houston, Texas 77005, United States
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Yage Zhao
- Department of Physics&Astronomy, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Andrea Toma
- Istituto Italiano di Tecnologia, 16163 Genova, Italy
| | | | - Burak Gerislioglu
- Department of Physics&Astronomy, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Yigao Yuan
- Department of Chemistry, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Minghe Lou
- Department of Chemistry, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Adebola Ogundare
- Department of Chemistry, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Alessandro Alabastri
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Peter Nordlander
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
- Department of Materials Science and Nanoengineering, Rice University, Houston, Texas 77005, United States
- Department of Physics&Astronomy, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| | - Naomi J Halas
- Department of Chemistry, Rice University, Houston, Texas 77005, United States
- Department of Electrical and Computer Engineering, Rice University, Houston, Texas 77005, United States
- Department of Physics&Astronomy, Rice University, Houston, Texas 77005, United States
- Laboratory for Nanophotonics, Rice University, Houston, Texas 77005, United States
| |
Collapse
|
3
|
Schmid W, Danstrom IA, Echevarria MC, Adkinson J, Mattar L, Banks GP, Sheth SA, Watrous AJ, Heilbronner SR, Bijanki KR, Alabastri A, Bartoli E. A biophysically constrained brain connectivity model based on stimulation-evoked potentials. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.11.03.565525. [PMID: 37986830 PMCID: PMC10659345 DOI: 10.1101/2023.11.03.565525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
Background Single-pulse electrical stimulation (SPES) is an established technique used to map functional effective connectivity networks in treatment-refractory epilepsy patients undergoing intracranial-electroencephalography monitoring. While the connectivity path between stimulation and recording sites has been explored through the integration of structural connectivity, there are substantial gaps, such that new modeling approaches may advance our understanding of connectivity derived from SPES studies. New Method Using intracranial electrophysiology data recorded from a single patient undergoing sEEG evaluation, we employ an automated detection method to identify early response components, C1, from pulse-evoked potentials (PEPs) induced by SPES. C1 components were utilized for a novel topology optimization method, modeling 3D conductivity propagation from stimulation sites. Additionally, PEP features were compared with tractography metrics, and model results were analyzed with respect to anatomical features. Results The proposed optimization model resolved conductivity paths with low error. Specific electrode contacts displaying high error correlated with anatomical complexities. The C1 component strongly correlates with additional PEP features and displayed stable, weak correlations with tractography measures. Comparison with existing methods Existing methods for estimating conductivity propagation are imaging-based and thus rely on anatomical inferences. Conclusions These results demonstrate that informing topology optimization methods with human intracranial SPES data is a feasible method for generating 3D conductivity maps linking electrical pathways with functional neural ensembles. PEP-estimated effective connectivity is correlated with but distinguished from structural connectivity. Modeled conductivity resolves connectivity pathways in the absence of anatomical priors.
Collapse
Affiliation(s)
- William Schmid
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston 77005, Texas, USA
| | - Isabel A. Danstrom
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Maria Crespo Echevarria
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Joshua Adkinson
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Layth Mattar
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Garrett P. Banks
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Sameer A. Sheth
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Andrew J. Watrous
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Sarah R. Heilbronner
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Kelly R. Bijanki
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| | - Alessandro Alabastri
- Department of Electrical and Computer Engineering, Rice University, 6100 Main Street, Houston 77005, Texas, USA
| | - Eleonora Bartoli
- Department of Neurosurgery, Baylor College of Medicine, 1 Baylor Plaza, Houston 77030, Texas, USA
| |
Collapse
|