1
|
Palakollu VN, Veera Manohara Reddy Y, Shekh MI, Vattikuti SVP, Shim J, Karpoormath R. Electrochemical immunosensing of tumor markers. Clin Chim Acta 2024; 557:117882. [PMID: 38521164 DOI: 10.1016/j.cca.2024.117882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 03/19/2024] [Accepted: 03/20/2024] [Indexed: 03/25/2024]
Abstract
The rising incidence and mortality rates of cancer have led to a growing need for precise and prompt early diagnostic approaches to effectively combat this disease. However, traditional methods employed for detecting tumor cells, such as histopathological and immunological techniques, are often associated with complex procedures, high analytical expenses, elevated false positive rates, and a dependence on experienced personnel. Tracking tumor markers is recognized as one of the most effective approaches for early detection and prognosis of cancer. While onco-biomarkers can also be produced in normal circumstances, their concentration is significantly elevated when tumors are present. By monitoring the levels of these markers, healthcare professionals can obtain valuable insights into the presence, progression, and response to treatment of cancer, aiding in timely diagnosis and effective management. This review aims to provide researchers with a comprehensive overview of the recent advancements in tumor markers using electrochemical immunosensors. By highlighting the latest developments in this field, researchers can gain a general understanding of the progress made in the utilization of electrochemical immunosensors for detecting tumor markers. Furthermore, this review also discusses the current limitations associated with electrochemical immunosensors and offers insights into paving the way for further improvements and advancements in this area of research.
Collapse
Affiliation(s)
- Venkata Narayana Palakollu
- Department of Chemistry, School of Applied Sciences, REVA University, Bengaluru 560064, India; Department of Pharmaceutical Chemistry, College of Health Sciences, University of KwaZulu-Natal, Durban 4000, South Africa.
| | - Y Veera Manohara Reddy
- Department of Chemistry, Sri Venkateswara College, University of Delhi, New Delhi 110021, India
| | - Mehdihasan I Shekh
- College of Materials Science and Engineering, Shenzhen University, Shenzhen 518055, PR China
| | | | - Jaesool Shim
- School of Mechanical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Rajshekhar Karpoormath
- Department of Pharmaceutical Chemistry, College of Health Sciences, University of KwaZulu-Natal, Durban 4000, South Africa
| |
Collapse
|
2
|
Chen J, Song Z, Yang J. Whether carbon nanotubes are suitable for delivering small drugs with aromatic rings through non-covalent adsorption? J Mol Liq 2023. [DOI: 10.1016/j.molliq.2023.121595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
|
3
|
Tiwari S, Chopra L. Therapeutic nanoparticles for targeted drug delivery: A mini-review. AIP CONFERENCE PROCEEDINGS 2023; 2773:060005. [DOI: 10.1063/5.0113615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2025]
|
4
|
Ahmadian E, Janas D, Eftekhari A, Zare N. Application of carbon nanotubes in sensing/monitoring of pancreas and liver cancer. CHEMOSPHERE 2022; 302:134826. [PMID: 35525455 DOI: 10.1016/j.chemosphere.2022.134826] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/27/2022] [Accepted: 04/29/2022] [Indexed: 06/14/2023]
Abstract
Liver and pancreatic tumors are among the third leading causes of cancer-associated death worldwide. In addition to poor prognosis, both cancer types are diagnosed at advanced and metastatic stages without typical prior symptoms. Unfortunately, the existing theranostic approaches are inefficient in cancer diagnosis and treatment. Carbon nanotubes (CNTs) have attracted increasing attention in this context due to their distinct properties, including variable functionalization capability, biocompatibility, and excellent thermodynamic and optical features. As a consequence, they are now regarded as one of the most promising materials for this application. The current review aims to summarize and discuss the role of CNT in pancreatic and liver cancer theranostics. Accordingly, the breakthroughs achieved so far are classified based on the cancer type and analyzed in detail. The most feasible tactics utilizing CNT-based solutions for both cancer diagnosis and treatment are presented from the biomedical point of view. Finally, a future outlook is provided, which anticipates how the R&D community can build on the already developed methodologies and the subsequent biological responses of the pancreatic and liver cancer cells to the directed procedures.
Collapse
Affiliation(s)
- Elham Ahmadian
- Kidney Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Dawid Janas
- Department of Organic Chemistry, Bioorganic Chemistry and Biotechnology, Silesian University of Technology, B. Krzywoustego 4, 44-100, Gliwice, Poland.
| | - Aziz Eftekhari
- Department of Pharmacology & Toxicology, Tabriz University of Medical Sciences, Tabriz, Iran; Health Innovation & Acceleration Centre, Tabriz University of Medical Sciences, Tabriz, 51664, Iran; Joint Ukraine-Azerbaijan International Research and Education Center of Nanobiotechnology and Functional Nanosystems, Drohobych, Ukraine, Baku, Azerbaijan.
| | - Najme Zare
- Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran.
| |
Collapse
|
5
|
Moonla C, Chenkhuruthum S, Ouiram T, Preechaworapun A, Tapala W, Ngamchuea K, Tangkuaram T. A novel label‐free chronoamperometric immunosensor based on a biocomposite material for rapid detection of carcinoembryonic antigen. ELECTROANAL 2022. [DOI: 10.1002/elan.202100506] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
6
|
Park G, Kim HO, Lim JW, Park C, Yeom M, Song D, Haam S. Rapid detection of influenza A (H1N1) virus by conductive polymer-based nanoparticle via optical response to virus-specific binding. NANO RESEARCH 2021; 15:2254-2262. [PMID: 34567436 PMCID: PMC8453473 DOI: 10.1007/s12274-021-3772-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 07/22/2021] [Accepted: 07/25/2021] [Indexed: 05/28/2023]
Abstract
UNLABELLED A recurrent pandemic with unpredictable viral nature has implied the need for a rapid diagnostic technology to facilitate timely and appropriate countermeasures against viral infections. In this study, conductive polymer-based nanoparticles have been developed as a tool for rapid diagnosis of influenza A (H1N1) virus. The distinctive property of a conductive polymer that transduces stimulus to respond, enabled immediate optical signal processing for the specific recognition of H1N1 virus. Conductive poly(aniline-co-pyrrole)-encapsulated polymeric vesicles, functionalized with peptides, were fabricated for the specific recognition of H1N1 virus. The low solubility of conductive polymers was successfully improved by employing vesicles consisting of amphiphilic copolymers, facilitating the viral titer-dependent production of the optical response. The optical response of the detection system to the binding event with H1N1, a mechanical stimulation, was extensively analyzed and provided concordant information on viral titers of H1N1 virus in 15 min. The specificity toward the H1N1 virus was experimentally demonstrated via a negative optical response against the control group, H3N2. Therefore, the designed system that transduces the optical response to the target-specific binding can be a rapid tool for the diagnosis of H1N1. ELECTRONIC SUPPLEMENTARY MATERIAL Supplementary material (Table S1 and Figs. S1-S8) is available in the online version of this article at 10.1007/s12274-021-3772-6.
Collapse
Affiliation(s)
- Geunseon Park
- Department of Chemical & Biomolecular Engineering, Yonsei University, Seoul, 03722 Republic of Korea
| | - Hyun-Ouk Kim
- Division of Chemical Engineering and Bioengineering College of Art, Culture and Engineering, Kangwon National University, Chuncheon-si, Gangwon-do, 24341 Republic of Korea
- Biohealth-machinery Convergence Engineering, Kangwon National University, Chuncheon, Gangwon-do, 24341 Republic of Korea
| | - Jong-Woo Lim
- Department of Chemical & Biomolecular Engineering, Yonsei University, Seoul, 03722 Republic of Korea
| | - Chaewon Park
- Department of Chemical & Biomolecular Engineering, Yonsei University, Seoul, 03722 Republic of Korea
| | - Minjoo Yeom
- College of Pharmacy, Korea University, Sejong, 30019 Republic of Korea
| | - Daesub Song
- College of Pharmacy, Korea University, Sejong, 30019 Republic of Korea
| | - Seungjoo Haam
- Department of Chemical & Biomolecular Engineering, Yonsei University, Seoul, 03722 Republic of Korea
| |
Collapse
|
7
|
Nguyen TL, Takai M, Ishihara K, Oyama K, Fujii S, Yusa SI. Facile preparation of water-soluble multiwalled carbon nanotubes bearing phosphorylcholine groups for heat generation under near-infrared irradiation. Polym J 2021. [DOI: 10.1038/s41428-021-00495-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
8
|
Banerjee A, Maity S, Mastrangelo CH. Nanostructures for Biosensing, with a Brief Overview on Cancer Detection, IoT, and the Role of Machine Learning in Smart Biosensors. SENSORS (BASEL, SWITZERLAND) 2021; 21:1253. [PMID: 33578726 PMCID: PMC7916491 DOI: 10.3390/s21041253] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 02/04/2021] [Accepted: 02/07/2021] [Indexed: 01/03/2023]
Abstract
Biosensors are essential tools which have been traditionally used to monitor environmental pollution and detect the presence of toxic elements and biohazardous bacteria or virus in organic matter and biomolecules for clinical diagnostics. In the last couple of decades, the scientific community has witnessed their widespread application in the fields of military, health care, industrial process control, environmental monitoring, food-quality control, and microbiology. Biosensor technology has greatly evolved from in vitro studies based on the biosensing ability of organic beings to the highly sophisticated world of nanofabrication-enabled miniaturized biosensors. The incorporation of nanotechnology in the vast field of biosensing has led to the development of novel sensors and sensing mechanisms, as well as an increase in the sensitivity and performance of the existing biosensors. Additionally, the nanoscale dimension further assists the development of sensors for rapid and simple detection in vivo as well as the ability to probe single biomolecules and obtain critical information for their detection and analysis. However, the major drawbacks of this include, but are not limited to, potential toxicities associated with the unavoidable release of nanoparticles into the environment, miniaturization-induced unreliability, lack of automation, and difficulty of integrating the nanostructured-based biosensors, as well as unreliable transduction signals from these devices. Although the field of biosensors is vast, we intend to explore various nanotechnology-enabled biosensors as part of this review article and provide a brief description of their fundamental working principles and potential applications. The article aims to provide the reader a holistic overview of different nanostructures which have been used for biosensing purposes along with some specific applications in the field of cancer detection and the Internet of things (IoT), as well as a brief overview of machine-learning-based biosensing.
Collapse
Affiliation(s)
- Aishwaryadev Banerjee
- Department of Electrical & Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | - Swagata Maity
- Department of Condensed Matter Physics and Materials Sciences, S.N. Bose National Centre for Basic Sciences, Kolkata 700106, India;
| | - Carlos H. Mastrangelo
- Department of Electrical & Computer Engineering, University of Utah, Salt Lake City, UT 84112, USA
| |
Collapse
|
9
|
Zhang X, Shen Y, Shen G, Zhang C. Simple and Effective Approach to Prepare an Epoxy-Functionalized Polymer and Its Application for an Electrochemical Immunosensor. ACS OMEGA 2021; 6:3637-3643. [PMID: 33585744 PMCID: PMC7876694 DOI: 10.1021/acsomega.0c05183] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 01/14/2021] [Indexed: 06/12/2023]
Abstract
An epoxy-functionalized polymer based on a new skeleton has been prepared via an efficient method and it combined with aminated carbon nanotubes to form a new composite material. This new composite material was applied for the fabrication of an electrochemical immunosensor with good performance. The inexpensive and easily available IgG was used to test the performance of the prepared composite material. The levels of IgG were quantitatively analyzed using a differential pulse voltammetry detection system and the lowest detection limit was calculated to be 0.05 ng/mL. The detection system can also respond to IgG in the concentration range from 0.1 to 25 ng/mL.
Collapse
Affiliation(s)
- Xiangyang Zhang
- Hunan
Province Cooperative Innovation Center for the Construction &
Development of Dongting Lake Ecological Economic Zone, College of
Chemistry and Material Engineering, Hunan
University of Arts and Science, Changde 415000, P. R. China
- Hunan
Provincial Key Laboratory of Water Treatment Functional Materials, Hunan Province Engineering Research Center of Electroplating
Wastewater Reuse Technology, Changde 415000, P. R. China
| | - Youming Shen
- Hunan
Province Cooperative Innovation Center for the Construction &
Development of Dongting Lake Ecological Economic Zone, College of
Chemistry and Material Engineering, Hunan
University of Arts and Science, Changde 415000, P. R. China
- Hunan
Provincial Key Laboratory of Water Treatment Functional Materials, Hunan Province Engineering Research Center of Electroplating
Wastewater Reuse Technology, Changde 415000, P. R. China
| | - Guangyu Shen
- Hunan
Province Cooperative Innovation Center for the Construction &
Development of Dongting Lake Ecological Economic Zone, College of
Chemistry and Material Engineering, Hunan
University of Arts and Science, Changde 415000, P. R. China
| | - Chunxiang Zhang
- Hunan
Province Cooperative Innovation Center for the Construction &
Development of Dongting Lake Ecological Economic Zone, College of
Chemistry and Material Engineering, Hunan
University of Arts and Science, Changde 415000, P. R. China
| |
Collapse
|
10
|
Soleymani J, Hasanzadeh M, shadjou N, Somi MH, Jouyban A. The role of nanomaterials on the cancer cells sensing based on folate receptor: Analytical approach. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115834] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
11
|
Obernikhina N, Zhuravlova M, Kachkovsky O, Kobzar O, Brovarets V, Pavlenko O, Kulish M, Dmytrenko O. Stability of fullerene complexes with oxazoles as biologically active compounds. APPLIED NANOSCIENCE 2019. [DOI: 10.1007/s13204-019-01225-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
12
|
|
13
|
Abstract
Modern analysis of food and feed is mostly focused on development of fast and reliable portable devices intended for field applications. In this review, electrochemical biosensors based on immunological reactions and aptamers are considered in the determination of mycotoxins as one of most common contaminants able to negatively affect human health. The characteristics of biosensors are considered from the point of view of general principles of bioreceptor implementation and signal transduction providing sub-nanomolar detection limits of mycotoxins. Moreover, the modern trends of bioreceptor selection and modification are discussed as well as future trends of biosensor development for mycotoxin determination are considered.
Collapse
|
14
|
Devarakonda S, Singh R, Bhardwaj J, Jang J. Cost-Effective and Handmade Paper-Based Immunosensing Device for Electrochemical Detection of Influenza Virus. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2597. [PMID: 29137115 PMCID: PMC5713655 DOI: 10.3390/s17112597] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 11/08/2017] [Accepted: 11/09/2017] [Indexed: 02/04/2023]
Abstract
Although many studies concerning the detection of influenza virus have been published, a paper-based, label-free electrochemical immunosensor has never been reported. Here, we present a cost-effective, handmade paper-based immunosensor for label-free electrochemical detection of influenza virus H1N1. This immunosensor was prepared by modifying paper with a spray of hydrophobic silica nanoparticles, and using stencil-printed electrodes. We used a glass vaporizer to spray the hydrophobic silica nanoparticles onto the paper, rendering it super-hydrophobic. The super-hydrophobicity, which is essential for this paper-based biosensor, was achieved via 30-40 spray coatings, corresponding to a 0.39-0.41 mg cm-2 coating of nanoparticles on the paper and yielding a water contact angle of 150° ± 1°. Stencil-printed carbon electrodes modified with single-walled carbon nanotubes and chitosan were employed to increase the sensitivity of the sensor, and the antibodies were immobilized via glutaraldehyde cross-linking. Differential pulse voltammetry was used to assess the sensitivity of the sensors at various virus concentrations, ranging from 10 to 10⁴ PFU mL-1, and the selectivity was assessed against MS2 bacteriophages and the influenza B viruses. These immunosensors showed good linear behaviors, improved detection times (30 min), and selectivity for the H1N1 virus with a limit of detection of 113 PFU mL-1, which is sufficiently sensitive for rapid on-site diagnosis. The simple and inexpensive methodologies developed in this study have great potential to be used for the development of a low-cost and disposable immunosensor for detection of pathogenic microorganisms, especially in developing countries.
Collapse
Affiliation(s)
- Sivaranjani Devarakonda
- Department of Mechanical Engineering, School of Mechanical, Aerospace and Nuclear Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea.
| | - Renu Singh
- Department of Mechanical Engineering, School of Mechanical, Aerospace and Nuclear Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea.
| | - Jyoti Bhardwaj
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea.
| | - Jaesung Jang
- Department of Mechanical Engineering, School of Mechanical, Aerospace and Nuclear Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea.
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea.
| |
Collapse
|
15
|
Soares J, Iwaki LEO, Soares AC, Rodrigues VC, Melendez ME, Fregnani JHG, Reis RM, Carvalho AL, Corrêa DS, Oliveira ON. Immunosensor for Pancreatic Cancer Based on Electrospun Nanofibers Coated with Carbon Nanotubes or Gold Nanoparticles. ACS OMEGA 2017; 2:6975-6983. [PMID: 30023536 PMCID: PMC6044935 DOI: 10.1021/acsomega.7b01029] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 10/05/2017] [Indexed: 05/15/2023]
Abstract
We report the fabrication of immunosensors based on nanostructured mats of electrospun nanofibers of polyamide 6 and poly(allylamine hydrochloride) coated either with multiwalled carbon nanotubes (MWCNTs) or gold nanoparticles (AuNPs), whose three-dimensional structure was suitable for the immobilization of anti-CA19-9 antibodies to detect the pancreatic cancer biomarker CA19-9. Using impedance spectroscopy, the sensing platform was able to detect CA19-9 with a detection limit of 1.84 and 1.57 U mL-1 for the nanostructured architectures containing MWCNTs and AuNPs, respectively. The high sensitivity achieved can be attributed to the irreversible adsorption between antibodies and antigens, as confirmed with polarization-modulated infrared reflection absorption spectroscopy. The adsorption mechanism was typical Langmuir-Freundlich processes. The high sensitivity and selectivity of the immunosensors were also explored in tests with blood serum from patients with distinct concentrations of CA19-9, for which the impedance spectra data were processed with a multidimensional projection technique. The robustness of the immunosensors in dealing with patient samples without suffering interference from analytes present in biological fluids is promising for a simple, effective diagnosis of pancreatic cancer at early stages.
Collapse
Affiliation(s)
- Juliana
C. Soares
- São
Carlos Institute of Physics, University
of São Paulo, 13560-60 São Carlos, Brazil
| | - Leonardo E. O. Iwaki
- São
Carlos Institute of Physics, University
of São Paulo, 13560-60 São Carlos, Brazil
- Department
of Materials Engineering, São Carlos School of Engineering, University of São Paulo, 13563-120 São Carlos, Brazil
| | - Andrey C. Soares
- São
Carlos Institute of Physics, University
of São Paulo, 13560-60 São Carlos, Brazil
- Department
of Materials Engineering, São Carlos School of Engineering, University of São Paulo, 13563-120 São Carlos, Brazil
| | | | - Matias E. Melendez
- Molecular
Oncology Research Center, Barretos Cancer
Hospital, 14784-400 Barretos, Brazil
| | | | - Rui M. Reis
- Molecular
Oncology Research Center, Barretos Cancer
Hospital, 14784-400 Barretos, Brazil
- ICVS/3B’s-PT
Government Associate Laboratory, Life and Health Sciences Research
Institute (ICVS), University of Minho, 4710-057 Braga, Portugal
| | - Andre L. Carvalho
- Molecular
Oncology Research Center, Barretos Cancer
Hospital, 14784-400 Barretos, Brazil
| | - Daniel S. Corrêa
- Nanotechnology
National Laboratory for Agriculture (LNNA), Embrapa Instrumentação, 13560-970 São Carlos, Brazil
| | - Osvaldo N. Oliveira
- São
Carlos Institute of Physics, University
of São Paulo, 13560-60 São Carlos, Brazil
| |
Collapse
|
16
|
Wang H, Akcora P. Confinement effect on the structure and elasticity of proteins interfacing polymers. SOFT MATTER 2017; 13:1561-1568. [PMID: 28127605 DOI: 10.1039/c6sm02179d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The ordered nanostructured surfaces provide confined environments that allow functionalization of proteins. Here, we used the nanopores of poly(methyl methacrylate) films to attach fibrinogen and lysozyme, and discussed the changes in proteins' structures and elasticity upon confinement. Fourier-transform infrared spectroscopic analysis of protein secondary structures reveals that fibrinogen undergoes less structural change and behaves less stiff when the pore size is close to the protein size. Lysozyme, on the other hand, retains its native-like structure, however, it exhibits the highest modulus in 15 nm pores due to the lower macromolecular crowding effect the protein faces compared to lysozyme within larger pores. These findings manifest the effect of confinement and crowding on the conformation and elasticity of different shaped proteins tethered on surfaces.
Collapse
Affiliation(s)
- Haoyu Wang
- Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, 1 Castle Point on Hudson, Hoboken, New Jersey 07030, USA.
| | - Pinar Akcora
- Department of Chemical Engineering and Materials Science, Stevens Institute of Technology, 1 Castle Point on Hudson, Hoboken, New Jersey 07030, USA.
| |
Collapse
|
17
|
Zhu Z. An Overview of Carbon Nanotubes and Graphene for Biosensing Applications. NANO-MICRO LETTERS 2017; 9:25. [PMID: 30393720 PMCID: PMC6199032 DOI: 10.1007/s40820-017-0128-6] [Citation(s) in RCA: 122] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2016] [Accepted: 01/04/2017] [Indexed: 05/15/2023]
Abstract
With the development of carbon nanomaterials in recent years, there has been an explosion of interests in using carbon nanotubes (CNTs) and graphene for developing new biosensors. It is believed that employing CNTs and graphene as sensor components can make sensors more reliable, accurate, and fast due to their remarkable properties. Depending on the types of target molecular, different strategies can be applied to design sensor device. This review article summarized the important progress in developing CNT- and graphene-based electrochemical biosensors, field-effect transistor biosensors, and optical biosensors. Although CNTs and graphene have led to some groundbreaking discoveries, challenges are still remained and the state-of-the-art sensors are far from a practical application. As a conclusion, future effort has to be made through an interdisciplinary platform, including materials science, biology, and electric engineering.
Collapse
Affiliation(s)
- Zanzan Zhu
- National Cancer Centre Singapore, 11 Hospital Drive, Singapore, 169610 Singapore
| |
Collapse
|
18
|
Baldo S, Buccheri S, Ballo A, Camarda M, La Magna A, Castagna M, Romano A, Iannazzo D, Di Raimondo F, Neri G, Scalese S. Carbon nanotube-based sensing devices for human Arginase-1 detection. SENSING AND BIO-SENSING RESEARCH 2016. [DOI: 10.1016/j.sbsr.2015.11.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
19
|
Abstract
Nanomaterials possess unique features which make them particularly attractive for biosensing applications. In particular, carbon nanotubes (CNTs) can serve as scaffolds for immobilization of biomolecules at their surface, and combine several exceptional physical, chemical, electrical, and optical characteristics properties which make them one of the best suited materials for the transduction of signals associated with the recognition of analytes, metabolites, or disease biomarkers. Here we provide a comprehensive review on these carbon nanostructures, in which we describe their structural and physical properties, functionalization and cellular uptake, biocompatibility, and toxicity issues. We further review historical developments in the field of biosensors, and describe the different types of biosensors which have been developed over time, with specific focus on CNT-conjugates engineered for biosensing applications, and in particular detection of cancer biomarkers.
Collapse
Affiliation(s)
| | - May C. Morris
- Cell Cycle Biosensors and Inhibitors, Faculté de Pharmacie, Institut des Biomolécules Max Mousseron, Centre National de la Recherche Scientifique-UMR 5247Montpellier, France
| |
Collapse
|
20
|
Hori N, Chikae M, Kirimura H, Takamura Y. pH dependence of non-specific adsorption and detection solution in electrochemical metalloimmunoassay using antibody–silver nanoparticle conjugates. SENSING AND BIO-SENSING RESEARCH 2015. [DOI: 10.1016/j.sbsr.2015.07.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
21
|
Singh R, Sharma A, Hong S, Jang J. Electrical immunosensor based on dielectrophoretically-deposited carbon nanotubes for detection of influenza virus H1N1. Analyst 2015; 139:5415-21. [PMID: 25232557 DOI: 10.1039/c4an01335b] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The influenza virus has received extensive attention due to the recent H1N1 pandemics originating from swine. This study reports a label-free, highly sensitive, and selective electrical immunosensor for the detection of influenza virus H1N1 based on dielectrophoretically deposited single-walled carbon nanotubes (SWCNTs). COOH-functionalized SWCNTs were deposited on a self-assembled monolayer of polyelectrolyte polydiallyldimethyl-ammonium chloride (PDDA) between two gold electrodes by dielectrophoretic and electrostatic forces, which resulted in reproducible, uniform, aligned, and aggregation-free SWCNT channels (2-10 μm in length). Avidin was immobilized onto the PDDA-SWCNT channels, and viral antibodies were immobilized using biotin-avidin coupling. The resistance of the channels increased with the binding of the influenza viruses to the antibodies. These immunosensors showed linear behavior as the virus concentration was varied from 1 to 10(4) PFU ml(-1) along with a detection time of 30 min. The immunosensors with a 2 μm channel length detected 1 PFU ml(-1) of the influenza virus accurately (R(2) = 0.99) and selectively from MS2 bacteriophages. These immunosensors have the potential to become an important component of a point-of-care test kit that will enable a rapid clinical diagnosis.
Collapse
Affiliation(s)
- Renu Singh
- School of Mechanical and Nuclear Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 689-798, Republic of Korea.
| | | | | | | |
Collapse
|
22
|
Schwartz O, Bercovici M. Microfluidic Assay for Continuous Bacteria Detection Using Antimicrobial Peptides and Isotachophoresis. Anal Chem 2014; 86:10106-13. [DOI: 10.1021/ac5017776] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Ortal Schwartz
- Russell
Berrie Nanotechnology Institute, Technion − Israel Institute of Technology, Haifa 32000, Israel
| | - Moran Bercovici
- Russell
Berrie Nanotechnology Institute, Technion − Israel Institute of Technology, Haifa 32000, Israel
- Faculty
of Mechanical Engineering, Technion − Israel Institute of Technology, Haifa 32000, Israel
| |
Collapse
|
23
|
Chehel Amirani M, Tang T. Binding of nucleobases with graphene and carbon nanotube: a review of computational studies. J Biomol Struct Dyn 2014; 33:1567-97. [DOI: 10.1080/07391102.2014.954315] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
24
|
Ward A, Petrie A, Honek JF, Tang XS. Analyte-Dependent Sensing Mechanisms: The Fabrication and Characterization of a 32-Channel Array of SWCNT-TF Chemiresistive Sensors. IEEE NANOTECHNOLOGY MAGAZINE 2014. [DOI: 10.1109/mnano.2014.2313211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
25
|
Rusling JF, Bishop GW, Doan N, Papadimitrakopoulos F. Nanomaterials and biomaterials in electrochemical arrays for protein detection. J Mater Chem B 2014; 2:10.1039/C3TB21323D. [PMID: 24392222 PMCID: PMC3878175 DOI: 10.1039/c3tb21323d] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Nanomaterials and biomaterials are important components of new electrochemical arrays designed for sensitive detection of proteins in biological fluids. Such multiplexed protein arrays are predicted to have an important future in personalized medical diagnostics, especially for cancer and heart disease. Sandwich immunoassays for proteins benefit greatly in sensitivity from the use of nanostructured sensor surfaces and multilabeled detection strategies involving nano- or microparticles. In these assays, capture agents such as antibodies or aptamers are attached to sensor surfaces in the array. Target proteins with large binding constants for the affinity agents are captured from liquid samples with high efficiency, either on the sensors or on magnetic bioconjugate particles decorated with many copies of labels and antibodies. After target proteins are captured on the sensor surfaces, the labels are detected by electrochemical techniques. This feature article begins with an overview of the recent history of nanoparticles in electrochemical protein sensors, then moves on to specific examples from our own laboratories. We discuss fabrication of nanostructured sensors and arrays with the aim of multiplexed detection as well as reusability. Following this, we describe systems that integrate particle-based protein sensing with microfluidics for multiplexed protein detection. We end with predictions on the diagnostic future of protein detection.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA ; Institute of Materials Science, University of Connecticut, Storrs, CT 06269-3136, USA ; Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032, USA ; School of Chemistry, National University of Ireland at Galway, Ireland
| | - Gregory W Bishop
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA
| | - Nhi Doan
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA
| | - Fotios Papadimitrakopoulos
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA ; Institute of Materials Science, University of Connecticut, Storrs, CT 06269-3136, USA
| |
Collapse
|
26
|
Hui J, Li W, Guo Y, Yang Z, Wang Y, Yu C. Electrochemical sensor for sensitive detection of paracetamol based on novel multi-walled carbon nanotubes-derived organic–inorganic material. Bioprocess Biosyst Eng 2013; 37:461-8. [DOI: 10.1007/s00449-013-1013-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Accepted: 07/08/2013] [Indexed: 01/12/2023]
|
27
|
Poboży E, Filaber M, Koc A, Garcia-Reyes JF. Application of capillary electrophoretic chips in protein profiling of plant extracts for identification of genetic modifications of maize. Electrophoresis 2013; 34:2740-53. [DOI: 10.1002/elps.201300103] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2013] [Revised: 06/05/2013] [Accepted: 06/10/2013] [Indexed: 12/15/2022]
Affiliation(s)
- Ewa Poboży
- Department of Chemistry; University of Warsaw; Warsaw; Poland
| | - Monika Filaber
- Department of Chemistry; University of Warsaw; Warsaw; Poland
| | - Anna Koc
- Department of Chemistry; University of Warsaw; Warsaw; Poland
| | - Juan F. Garcia-Reyes
- Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry; University of Jaén; Jaén; Spain
| |
Collapse
|
28
|
Rusling JF. Multiplexed electrochemical protein detection and translation to personalized cancer diagnostics. Anal Chem 2013; 85:5304-10. [PMID: 23635325 PMCID: PMC3674208 DOI: 10.1021/ac401058v] [Citation(s) in RCA: 103] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Measuring diagnostic panels of multiple proteins promises a new, personalized approach to early detection and therapy of diseases like cancer. Levels of biomarker proteins in patient serum can provide a continually updated record of disease status. Research in electrochemical detection of proteins has produced exquisitely sensitive approaches. Most utilize ELISA-like sandwich immunoassays incorporating various aspects of nanotechnology. Several of these ultrasensitive methodologies have been extended to microfluidic multiplexed protein detection, but engineered solutions are needed to measure more proteins in a single device from a small patient sample such as a drop of blood or tissue lysate. To achieve clinical or point-of-care (POC) use, simplicity and low cost are essential. In multiplexed microfluidic immunoassays, required reagent additions and washing steps pose a significant problem calling for creative engineering. A grand challenge is to develop a general cancer screening device to accurately measure 50-100 proteins in a simple, cost-effective fashion. This will require creative solutions to simplified reagent addition and multiplexing.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry (U-3060), University of Connecticut, 55 North Eagleville Road, Storrs, CT 06269, USA.
| |
Collapse
|
29
|
Suginta W, Khunkaewla P, Schulte A. Electrochemical Biosensor Applications of Polysaccharides Chitin and Chitosan. Chem Rev 2013; 113:5458-79. [DOI: 10.1021/cr300325r] [Citation(s) in RCA: 341] [Impact Index Per Article: 28.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Wipa Suginta
- Biochemistry and Electrochemistry
Research Unit, Schools
of Chemistry and Biochemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima
30000, Thailand
| | - Panida Khunkaewla
- Biochemistry and Electrochemistry
Research Unit, Schools
of Chemistry and Biochemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima
30000, Thailand
| | - Albert Schulte
- Biochemistry and Electrochemistry
Research Unit, Schools
of Chemistry and Biochemistry, Institute of Science, Suranaree University of Technology, Nakhon Ratchasima
30000, Thailand
| |
Collapse
|
30
|
An enhanced impedance cytosensor based on folate conjugated-polyethylenimine-carbon nanotubes for tumor targeting. Electrochem commun 2013. [DOI: 10.1016/j.elecom.2012.12.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
31
|
Xuan Viet N, Chikae M, Ukita Y, Maehashi K, Matsumoto K, Tamiya E, Hung Viet P, Takamura Y. Gold-linked electrochemical immunoassay on single-walled carbon nanotube for highly sensitive detection of human chorionic gonadotropinhormone. Biosens Bioelectron 2013; 42:592-7. [DOI: 10.1016/j.bios.2012.11.017] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2012] [Revised: 11/13/2012] [Accepted: 11/14/2012] [Indexed: 01/02/2023]
|
32
|
Sapsford KE, Algar WR, Berti L, Gemmill KB, Casey BJ, Oh E, Stewart MH, Medintz IL. Functionalizing nanoparticles with biological molecules: developing chemistries that facilitate nanotechnology. Chem Rev 2013; 113:1904-2074. [PMID: 23432378 DOI: 10.1021/cr300143v] [Citation(s) in RCA: 830] [Impact Index Per Article: 69.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Kim E Sapsford
- Division of Biology, Department of Chemistry and Materials Science, Office of Science and Engineering Laboratories, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Lai X, Blazer-Yost BL, Clack JW, Fears SL, Mitra S, Ntim SA, Ringham HN, Witzmann FA. Protein expression profiles of intestinal epithelial co-cultures: effect of functionalised carbon nanotube exposure. ACTA ACUST UNITED AC 2013; 3. [PMID: 24228069 DOI: 10.1504/ijbnn.2013.054508] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
To assess the biological effects of low level, water dispersible, functionalised carbon nanotube (f-CNT) exposure in an in vitro model simulating the digestive tract, cellular protein expression was quantified and compared using label-free quantitative mass spectrometry (LFQMS). Co-cultured cells were exposed to well-characterised SWCNT-COOH, MWCNT-COOH, and MWCNT-PVP. The relative expression of 2,282 unique proteins was compared across the dose groups. 428 proteins were found to be differentially expressed. At the high dose, the extent of differential protein expression was CNT-specific and directly related to CNT colloidal stability. Cells responded to low level MWCNT-PVP exposure with three-fold greater differential expression. Bioinformatic analysis indicated significant and f-CNT-specific effects on relevant molecular and cellular functions and canonical pathways, with little overlap across f-CNT type and in the absence of overt toxicity.
Collapse
Affiliation(s)
- Xianyin Lai
- Department of Cellular and Integrative Physiology, Indiana University School of Medicine, 1345 West 16th Street, Indianapolis IN 46202, USA,
| | | | | | | | | | | | | | | |
Collapse
|
34
|
Chen KJ, Lee CF, Rick J, Wang SH, Liu CC, Hwang BJ. Fabrication and application of amperometric glucose biosensor based on a novel PtPd bimetallic nanoparticle decorated multi-walled carbon nanotube catalyst. Biosens Bioelectron 2012; 33:75-81. [DOI: 10.1016/j.bios.2011.12.020] [Citation(s) in RCA: 115] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2011] [Revised: 12/05/2011] [Accepted: 12/14/2011] [Indexed: 11/15/2022]
|
35
|
Rusling JF. Nanomaterials-based electrochemical immunosensors for proteins. CHEM REC 2012; 12:164-76. [PMID: 22287094 DOI: 10.1002/tcr.201100034] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2011] [Indexed: 02/06/2023]
Abstract
For this special issue on 90 years of polarography, the following personal account describes how my early research in electrochemistry and polarography in the laboratory of Prof. Petr Zuman led to a major research effort in the determination of proteins for cancer detection and monitoring. It reviews the very recent history of nanoparticle labels and multiplexed detection in protein immunosensors. It then describes our journey of discovery that has led to ultrasensitive protein immunosensors achieved by combining nanostructured electrodes with particles labeled with up to ½ million enzymes that can detect down to as little as 1 fg mL(-1) protein in diluted serum. Our most mature multiple protein detection system is a microfluidic device with eight sensors coated with 5-nm gold nanoparticles that uses off-line protein detection with heavily labeled magnetic particles. This approach has led to reliable sub pg mL(-1) detection limits for multiple proteins, provides excellent correlation with referee ELISA methods, and is currently being used for validation of panels of biomarkers for oral and prostate cancer. The article ends with a section on future perspectives.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry and Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, USA.
| |
Collapse
|
36
|
Wani TA, Darwish IA. An automated flow immunosensor based on kinetic exclusion analysis for measurement of a free β-subunit of human chorionic gonadotropin in serum. NEW J CHEM 2012. [DOI: 10.1039/c2nj00003b] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
37
|
Hong C, Yuan R, Chai Y, Zhuo Y, Yang X. A strategy for signal amplification using an amperometric enzyme immunosensor based on HRP modified platinum nanoparticles. J Electroanal Chem (Lausanne) 2012. [DOI: 10.1016/j.jelechem.2011.10.009] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|
38
|
Optimization of protein patterns for neuronal cell culture applications. Biointerphases 2011; 6:105. [DOI: 10.1116/1.3624584] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
39
|
Feng W, Ji P. Enzymes immobilized on carbon nanotubes. Biotechnol Adv 2011; 29:889-95. [PMID: 21820044 DOI: 10.1016/j.biotechadv.2011.07.007] [Citation(s) in RCA: 263] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2011] [Revised: 07/13/2011] [Accepted: 07/13/2011] [Indexed: 11/25/2022]
Abstract
Enzyme immobilizations on carbon nanotubes for fabrication of biosensors and biofuel cells and for preparation of biocatalysts are rapidly emerging as new research areas. Various immobilization methods have been developed, and in particular, specific attachment of enzymes on carbon nanotubes has been an important focus of attention. The method of immobilization has an effect on the preservation of the enzyme structure and retention of the native biological function of the enzyme. In this review, we focus on recent advances in methodology for enzyme immobilization on carbon nanotubes.
Collapse
Affiliation(s)
- Wei Feng
- Department of Biochemical Engineering, Beijing University of Chemical Technology, Beijing, China.
| | | |
Collapse
|
40
|
D'Orazio P. Biosensors in clinical chemistry - 2011 update. Clin Chim Acta 2011; 412:1749-61. [PMID: 21729694 PMCID: PMC7094392 DOI: 10.1016/j.cca.2011.06.025] [Citation(s) in RCA: 131] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2011] [Revised: 06/20/2011] [Accepted: 06/21/2011] [Indexed: 12/19/2022]
Abstract
Research activity and applications of biosensors for measurement of analytes of clinical interest over the last eight years are reviewed. Nanotechnology has been applied to improve performance of biosensors using electrochemical, optical, mechanical and physical modes of transduction, and to allow arrays of biosensors to be constructed for parallel sensing. Biosensors have been proposed for measurement of cancer biomarkers, cardiac biomarkers as well as biomarkers for autoimmune disease, infectious disease and for DNA analysis. Novel applications of biosensors include measurements in alternate sample types, such as saliva. Biosensors based on immobilized whole cells have found new applications, for example to detect the presence of cancer and to monitor the response of cancer cells to chemotherapeutic agents. The number of research reports describing new biosensors for analytes of clinical interest continues to increase; however, movement of biosensors from the research laboratory to the clinical laboratory has been slow. The greatest impact of biosensors will be felt at point-of-care testing locations without laboratory support. Integration of biosensors into reliable, easy-to-use and rugged instrumentation will be required to assure success of biosensor-based systems at the point-of-care.
Collapse
Affiliation(s)
- Paul D'Orazio
- Instrumentation Laboratory, Bedford, MA 01730, United States.
| |
Collapse
|
41
|
Protein biosensors based on polymer nanowires, carbon nanotubes and zinc oxide nanorods. SENSORS 2011; 11:5087-111. [PMID: 22163892 PMCID: PMC3231366 DOI: 10.3390/s110505087] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2011] [Revised: 05/03/2011] [Accepted: 05/05/2011] [Indexed: 11/17/2022]
Abstract
The development of biosensors using electrochemical methods is a promising application in the field of biotechnology. High sensitivity sensors for the bio-detection of proteins have been developed using several kinds of nanomaterials. The performance of the sensors depends on the type of nanostructures with which the biomaterials interact. One dimensional (1-D) structures such as nanowires, nanotubes and nanorods are proven to have high potential for bio-applications. In this paper we review these three different kinds of nanostructures that have attracted much attention at recent times with their great performance as biosensors. Materials such as polymers, carbon and zinc oxide have been widely used for the fabrication of nanostructures because of their enhanced performance in terms of sensitivity, biocompatibility, and ease of preparation. Thus we consider polymer nanowires, carbon nanotubes and zinc oxide nanorods for discussion in this paper. We consider three stages in the development of biosensors: (a) fabrication of biomaterials into nanostructures, (b) alignment of the nanostructures and (c) immobilization of proteins. Two different methods by which the biosensors can be developed at each stage for all the three nanostructures are examined. Finally, we conclude by mentioning some of the major challenges faced by many researchers who seek to fabricate biosensors for real time applications.
Collapse
|
42
|
Bellan LM, Wu D, Langer RS. Current trends in nanobiosensor technology. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2011; 3:229-46. [PMID: 21391305 PMCID: PMC4126610 DOI: 10.1002/wnan.136] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The development of tools and processes used to fabricate, measure, and image nanoscale objects has lead to a wide range of work devoted to producing sensors that interact with extremely small numbers (or an extremely small concentration) of analyte molecules. These advances are particularly exciting in the context of biosensing, where the demands for low concentration detection and high specificity are great. Nanoscale biosensors, or nanobiosensors, provide researchers with an unprecedented level of sensitivity, often to the single molecule level. The use of biomolecule-functionalized surfaces can dramatically boost the specificity of the detection system, but can also yield reproducibility problems and increased complexity. Several nanobiosensor architectures based on mechanical devices, optical resonators, functionalized nanoparticles, nanowires, nanotubes, and nanofibers have been demonstrated in the lab. As nanobiosensor technology becomes more refined and reliable, it is likely it will eventually make its way from the lab to the clinic, where future lab-on-a-chip devices incorporating an array of nanobiosensors could be used for rapid screening of a wide variety of analytes at low cost using small samples of patient material.
Collapse
Affiliation(s)
- Leon M Bellan
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
| | | | | |
Collapse
|
43
|
Tamesue S, Takashima Y, Yamaguchi H, Shinkai S, Harada A. Photochemically Controlled Supramolecular Curdlan/Single-Walled Carbon Nanotube Composite Gel: Preparation of Molecular Distaff by Cyclodextrin Modified Curdlan and Phase Transition Control. European J Org Chem 2011. [DOI: 10.1002/ejoc.201100077] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
44
|
Chunglok W, Wuragil DK, Oaew S, Somasundrum M, Surareungchai W. Immunoassay based on carbon nanotubes-enhanced ELISA for Salmonella enterica serovar Typhimurium. Biosens Bioelectron 2011; 26:3584-9. [DOI: 10.1016/j.bios.2011.02.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2010] [Revised: 02/01/2011] [Accepted: 02/04/2011] [Indexed: 10/18/2022]
|
45
|
Yang H, Yuan R, Chai Y, Zhuo Y. Electrochemically deposited nanocomposite of chitosan and carbon nanotubes for detection of human chorionic gonadotrophin. Colloids Surf B Biointerfaces 2011; 82:463-9. [DOI: 10.1016/j.colsurfb.2010.10.003] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2010] [Revised: 09/06/2010] [Accepted: 10/01/2010] [Indexed: 01/02/2023]
|
46
|
Bourigua S, Hnaien M, Bessueille F, Lagarde F, Dzyadevych S, Maaref A, Bausells J, Errachid A, Renault NJ. Impedimetric immunosensor based on SWCNT-COOH modified gold microelectrodes for label-free detection of deep venous thrombosis biomarker. Biosens Bioelectron 2010; 26:1278-82. [DOI: 10.1016/j.bios.2010.07.004] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Revised: 07/01/2010] [Accepted: 07/02/2010] [Indexed: 11/25/2022]
|
47
|
Examination of incubation time of bare gold electrode inside cysteamine solution for immobilization of multi-walled carbon nanotubes on a gold electrode modified with cysteamine. Mikrochim Acta 2010. [DOI: 10.1007/s00604-010-0469-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
48
|
Rusling JF, Kumar CV, Gutkind JS, Patel V. Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer. Analyst 2010; 135:2496-511. [PMID: 20614087 DOI: 10.1039/c0an00204f] [Citation(s) in RCA: 361] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
This critical review evaluates progress toward viable point-of-care protein biomarker measurements for cancer detection and diagnostics. The ability to measure panels of specific, selective cancer biomarker proteins in physicians' surgeries and clinics has the potential to revolutionize cancer detection, monitoring, and therapy. The dream envisions reliable, cheap, automated, technically undemanding devices that can analyze a patient's serum or saliva in a clinical setting, allowing on-the-spot diagnosis. Existing commercial products for protein assays are reliable in laboratory settings, but have limitations for point-of-care applications. A number of ultrasensitive immunosensors and some arrays have been developed, many based on nanotechnology. Multilabel detection coupled with high capture molecule density in immunosensors and arrays seems to be capable of detecting a wide range of protein concentrations with sensitivity ranging into the sub pg mL(-1) level. Multilabel arrays can be designed to detect both high and ultralow abundance proteins in the same sample. However, only a few of the newer ultrasensitive methods have been evaluated with real patient samples, which is key to establishing clinical sensitivity and selectivity.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry, University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA.
| | | | | | | |
Collapse
|
49
|
Munge BS, Fisher J, Millord LN, Krause CE, Dowd RS, Rusling JF. Sensitive electrochemical immunosensor for matrix metalloproteinase-3 based on single-wall carbon nanotubes. Analyst 2010; 135:1345-50. [PMID: 20358056 PMCID: PMC2923849 DOI: 10.1039/c0an00028k] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel electrochemical immunosensor for the detection of matrix metalloproteinase-3 (MMP-3), a cancer biomarker protein, based on vertically aligned single-wall carbon nanotube (SWCNT) arrays is presented. Detection was based on a sandwich immunoassay consisting of horseradish peroxidase (14-16 labels) conjugated to a secondary antibody and/or a polymer bead loaded with multi-enzyme labels. Performance was optimized by effective minimization of non-specific binding (NSB) events using Bovine serum albumin (BSA), Tween-20 and optimization of the primary antibody and secondary antibody concentrations. Results provided a detection limit of 0.4 ng mL(-1) (7.7 pM) for the 14-16 label sensor protocol and 4 pg mL(-1) (77 fM) using a multiply enzyme labeled polymeric bead amplification strategy in 10 microL of calf serum. This immunosensor based on SWCNT arrays offers great promise for a rapid, simple, cost-effective method for clinical screening of cancer biomarkers for point-of-care diagnosis.
Collapse
Affiliation(s)
- Bernard S Munge
- Salve Regina University, Department of Chemistry, Newport, Rhode Island 02840-4192, USA.
| | | | | | | | | | | |
Collapse
|
50
|
Hu W, Lu Z, Liu Y, Li CM. In situ surface plasmon resonance investigation of the assembly process of multiwalled carbon nanotubes on an alkanethiol self-assembled monolayer for efficient protein immobilization and detection. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:8386-8391. [PMID: 20201594 DOI: 10.1021/la9048105] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
In situ surface plasmon resonance (SPR) was used to study the assembly process of multiwalled carbon nanotubes (MWCNTs) quantitatively on an alkanethiol self-assembled monolayer (SAM) surface, showing that MWCNTs can follow the Langmuir adsorption kinetics to assemble spontaneously whereas the assembly temperature has an essential influence on the assembly kinetics and the surface distribution of MWCNTs. To further in situ investigate protein attachment on the MWCNT surface and its sensing application quantitatively, goat IgG was immobilized by three strategies: direct adsorption, covalent binding, and 1-pyrenebutanoic acid, succinimidyl ester (PBSE)-assisted attachment, of which the covalent binding approach provides the best protein loading capacity. The SPR label-free detection of anti-goat IgG demonstrates excellent performance with high sensitivity, good specificity, and rapid response in comparison to that with a plain substrate without MWCNT assembly reported in our previous work. This is contributed by the 3D MWCNT assembly matrix providing a high probe immobilization capability and superb accessibility for the target to enhance its sensing performance significantly.
Collapse
Affiliation(s)
- Weihua Hu
- School of Chemical & Biomedical Engineering, Center for Advanced Bionanosystems, Nanyang Technological University, 70 Nanyang Drive, Singapore 637457
| | | | | | | |
Collapse
|