1
|
Chen W, Yuan K, He Q, Li Q, Luo J, Chu F, Wang H, Feng H, Pan Y. Long term online desalting analysis of MS/LC-MS using thermal assisted recrystallization ionization. Talanta 2024; 274:125981. [PMID: 38583325 DOI: 10.1016/j.talanta.2024.125981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 03/06/2024] [Accepted: 03/20/2024] [Indexed: 04/09/2024]
Abstract
Mass spectrometric analysis of non-volatile salts containing samples remains challenging due to salt-induced ion suppression and contamination. This challenge is even more pronounced for a liquid chromatography-mass spectrometry analysis, where the accumulation of salts in the transmission system poses an ongoing problem. In this study, a novel thermal assisted recrystallization ionization mass spectrometry (TARI-MS) device was developed to achieve efficient on-line desalting and prolonged analysis of saline samples. The core component of this device was a heated plate positioned between the electrospray unit and the MS inlet. The desalting mechanism was demonstrated as the spontaneous separation of target molecules from salts during the "crystallization" process. After optimization, the angle between the nebulizer and the heated plate was 45°; the distance between the front end of the heated plate and the MS inlet was 2 mm; the distance between the front edge of the heated plate and the center of the sample spray projected onto the heating plate was 3 mm; the distance between the emitter of nebulizer and the heated plate was 3 mm. TARI-MS realized direct analysis of eight drugs dissolved in eight commonly used non-volatile salts solutions (up to 0.5 mol/L). The high sensitivity, repeatability, linearity, accuracy, and intra- and inter-day precision of TARI-MS confirm its reliability as a robust tool for the analysis of saline samples. Furthermore, TARI-MS allowed continuous analysis of salty eluates of LC for up to nearly 1 h without maintenance and verified the feasibility of LC-MS analysis through detecting a five-drug mixture and a crude aripiprazole product. Finally, six impurities in the crude aripiprazole product were successfully detected by LC-TARI-MS. The established method holds promise for applications across academic and pharmaceutical domains.
Collapse
Affiliation(s)
- Weiwei Chen
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Kailong Yuan
- China Tobacco Zhejiang Industrial Co., Ltd., Hangzhou, Zhejiang, 310008, PR China
| | - Quan He
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Qing Li
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Jing Luo
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Fengjian Chu
- Key Laboratory of Advanced Micro/Nano Electronic Devices and Smart Systems of Zhejiang, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Huiwen Wang
- Analysis Center of Agrobiology and Environmental Sciences, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China
| | - Hongru Feng
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China.
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou, 310027, Zhejiang, PR China.
| |
Collapse
|
2
|
Chen W, Li Q, Luo J, Pan Y, Feng H. Crystallization and Solvent Evaporation Ionization Mass Spectrometry (CSEI-MS) for Rapid Detection of Drugs in Complex Matrices. Anal Chem 2024; 96:8886-8892. [PMID: 38771107 DOI: 10.1021/acs.analchem.4c01469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
Illegal addition of drugs is common but seriously threatens public health safety. Conventional mass spectrometry methods are difficult to realize direct analysis of drugs existing in some complex matrices such as seawater or soil due to the ion suppression effect and contamination to MS parts caused by nonvolatile salts. In this work, a novel crystallization and solvent evaporation ionization mass spectrometry (CSEI-MS) method was constructed and developed to achieve rapid desalting detection. CSEI only consists of a heated plate and a nebulizer and exhibits excellent desalting performance, enabling direct analysis of six drugs dissolved in eight kinds of salt solutions (up to 200 mmol/L) and three complex salty matrices. Under optimized conditions, CSEI-MS presents high sensitivity, accuracy, linearity, and intraday and interday precision. Finally, this method is applied to the quantitative analysis of drugs in seawater, hand cream, and soil. Furthermore, the highly sensitive detection of CSEI-MS is demonstrated to remain even if the detection processes are conducted within 5 s via common commercial tools.
Collapse
Affiliation(s)
- Weiwei Chen
- Department of Chemistry, Zhejiang University, Hangzhou Zhejiang 310027, P. R. China
| | - Qing Li
- Department of Chemistry, Zhejiang University, Hangzhou Zhejiang 310027, P. R. China
| | - Jing Luo
- Department of Chemistry, Zhejiang University, Hangzhou Zhejiang 310027, P. R. China
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou Zhejiang 310027, P. R. China
| | - Hongru Feng
- Department of Chemistry, Zhejiang University, Hangzhou Zhejiang 310027, P. R. China
| |
Collapse
|
3
|
Pereira I, Sboto JNS, Robinson JL, Gill CG. Paper spray mass spectrometry combined with machine learning as a rapid diagnostic for chronic kidney disease. Analyst 2024; 149:2600-2608. [PMID: 38529879 DOI: 10.1039/d4an00099d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
A new analytical method for chronic kidney disease (CKD) detection utilizing paper spray mass spectrometry (PS-MS) combined with machine learning is presented. The analytical protocol is rapid and simple, based on metabolic profile alterations in urine. Anonymized raw urine samples were deposited (10 μL each) onto pointed PS-MS sample strips. Without waiting for the sample to dry, 75 μL of acetonitrile and high voltage were applied to the strips, using high resolution mass spectrometry measurement (15 s per sample) with polarity switching to detect a wide range of metabolites. Random forest machine learning was used to classify the resulting data. The diagnostic performance for the potential diagnosis of CKD was evaluated for accuracy, sensitivity, and specificity, achieving results >96% for the training data and >91% for validation and test data sets. Metabolites selected by the classification model as up- or down-regulated in healthy or CKD samples were tentatively identified and in agreement with previously reported literature. The potential utilization of this approach to discriminate albuminuria categories (normo, micro, and macroalbuminuria) was also demonstrated. This study indicates that PS-MS combined with machine learning has the potential to be used as a rapid and simple diagnostic tool for CKD.
Collapse
Affiliation(s)
- Igor Pereira
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, 900 Fifth Street, Nanaimo, BC, V9R 5S5, Canada.
| | - Jindar N S Sboto
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, 900 Fifth Street, Nanaimo, BC, V9R 5S5, Canada.
| | | | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, 900 Fifth Street, Nanaimo, BC, V9R 5S5, Canada.
- Chemistry Department, University of Victoria, Victoria, BC, V8P 5C2, Canada
- Chemistry Department, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
- Department of Occupational and Environmental Health Sciences, University of Washington, Seattle, WA, 98195-1618, USA
| |
Collapse
|
4
|
Hassan MTA, Chen X, Fnu PIJ, Osonga FJ, Sadik OA, Li M, Chen H. Rapid detection of per- and polyfluoroalkyl substances (PFAS) using paper spray-based mass spectrometry. JOURNAL OF HAZARDOUS MATERIALS 2024; 465:133366. [PMID: 38185081 DOI: 10.1016/j.jhazmat.2023.133366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 12/10/2023] [Accepted: 12/22/2023] [Indexed: 01/09/2024]
Abstract
Traditional PFAS analysis by mass spectrometry (MS) is time-consuming, as laborious sample preparation (e.g., extraction and desalting) is necessary. Herein, we report fast detection of PFAS by paper spray (PS)-based MS techniques, which employs a triangular-shaped filter paper for sample loading and ionization (≤ 3 min per sample). In this study, PS-MS was first used for direct PFAS analysis of drinking water, tap water, and wastewater. Interestingly, food package paper materials can be directly cut and examined with PS-MS for possible PFAS contamination. For samples containing salt matrices which would suppress PFAS ion signal, desalting paper spray mass spectrometry (DPS-MS), was shown to be capable of rapidly desalting, ionizing and detecting PFAS species such as per-fluorooctanoic acid (PFOA) and per-fluorosulphonic acid (PFOS). The retention of PFAS on paper substrate while salts being washed away by water is likely due to hydrophilic interaction between the PFAS polar head (e.g., carboxylic acid, sulfonic acid) with the polar filter paper cellulose surface. The DPS-MS method is highly sensitive (limits of detection:1.2-4.5 ppt) and can be applicable for directly analyzing soil extract and soil samples. These results suggest the high potential of PS-MS and the related DPS-MS technique in real-world environmental analysis of PFAS.
Collapse
Affiliation(s)
- Md Tanim-Al Hassan
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA
| | - Xingzhi Chen
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA
| | - Praneeth Ivan Joel Fnu
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA
| | - Francis J Osonga
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA
| | - Omowunmi A Sadik
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA
| | - Mengyan Li
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA
| | - Hao Chen
- Department of Chemistry and Environmental Science, New Jersey Institutes of Technology, University Heights, Newark, NJ 07102, USA.
| |
Collapse
|
5
|
Bhattarai M, Wang Q, Javaid T, Venkataraghavan A, Al Hassan MT, O'Neill M, Tan L, Chen H, Faik A. Streamlining assays of glycosyltransferases activity using in vitro GT-array (i-GT-ray) platform: Application to family GT37 fucosyltransferases. J Biol Chem 2024; 300:105734. [PMID: 38336294 PMCID: PMC10933551 DOI: 10.1016/j.jbc.2024.105734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 01/30/2024] [Accepted: 02/05/2024] [Indexed: 02/12/2024] Open
Abstract
Numerous putative glycosyltransferases (GTs) have been identified using bioinformatic approaches. However, demonstrating the activity of these GTs remains a challenge. Here, we describe the development of a rapid in vitro GT-array screening platform for activity of GTs. GT-arrays are generated by cell-free in vitro protein synthesis and binding using microplates precoated with a N-terminal Halo- or a C-terminal GST-tagged GT-encoding plasmid DNA and a capture antibody. These arrays are then used for screening of transferase activities and the reactions are monitored by a luminescence GLO assay. The products formed by these reactions can be analyzed directly from the microplates by mass spectrometry. Using this platform, a total of 280 assays were performed to screen 22 putative fucosyltransferases (FUTs) from family GT37 (seven from Arabidopsis and 15 from rice) for activity toward five acceptors: non-fucosylated tamarind xyloglucan (TXyG), arabinotriose (Ara3), non-fucosylated rhamnogalacturonan I (RG-I), and RG-II from the mur1-1 Arabidopsis mutant, and the celery RG-II monomer lacking Arap and MeFuc of chain B and l-Gal of chain A. Our screen showed that AtFUT2, AtFUT5, and AtFUT10 have activity toward RG-I, while AtFUT8 was active on RG-II. Five rice OsFUTs have XyG-FUT activity and four rice OsFUTs have activity toward Ara3. None of the putative OsFUTs were active on the RG-I and RG-II. However, promiscuity toward acceptors was observed for several FUTs. These findings extend our knowledge of cell wall polysaccharide fucosylation in plants. We believe that in vitro GT-array platform provides a valuable tool for cell wall biochemistry and other research fields.
Collapse
Affiliation(s)
- Matrika Bhattarai
- Department of Environmental and Plant Biology, Ohio University, Athens, Ohio, USA
| | - Qi Wang
- Department of Chemistry & Environmental Science, New Jersey Institute of Technology, Newark, New Jersey, USA
| | - Tasleem Javaid
- Department of Environmental and Plant Biology, Ohio University, Athens, Ohio, USA
| | | | - Md Tanim Al Hassan
- Department of Chemistry & Environmental Science, New Jersey Institute of Technology, Newark, New Jersey, USA
| | - Malcolm O'Neill
- Complex Carbohydrate Research Center, University of Georgia, Athens, Georgia, USA
| | - Li Tan
- Complex Carbohydrate Research Center, University of Georgia, Athens, Georgia, USA
| | - Hao Chen
- Department of Chemistry & Environmental Science, New Jersey Institute of Technology, Newark, New Jersey, USA
| | - Ahmed Faik
- Department of Environmental and Plant Biology, Ohio University, Athens, Ohio, USA.
| |
Collapse
|
6
|
Pereira I, Robinson JL, Gill CG. Simultaneous quantitation of urinary albumin and creatinine for rapid clinical albuminuria diagnostics using high-throughput paper spray mass spectrometry. Analyst 2024; 149:1102-1110. [PMID: 38093632 DOI: 10.1039/d3an01855e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2024]
Abstract
Albuminuria is a clinical condition associated with poor kidney function, diagnosed by determining the ratio of albumin to creatinine concentrations in patient urine samples. We present a high-throughput paper spray mass spectrometry (PS-MS) method for simultaneous quantitation of urinary albumin and creatinine for potential diagnosis of albuminuria. Minimal (urine dilution) or no sample preparation is required. The analytical performance of the method was evaluated, achieving linear calibration curves (R2 > 0.99) with little inter-day variability in the slope (N = 5 days), exhibiting coefficient of variation (CV) of 8% and 3% for albumin and creatinine, respectively. LOD and LOQ for albumin were 2.1 and 7.0 mg L-1, and for creatinine were 0.01 and 0.03 mmol L-1, respectively. Intra- and inter-day (N = 5) precisions (%CV) and accuracies (%bias) were <10% and ±11%, respectively, for both analytes. The method was applied to determine albumin-to-creatinine ratios in anonymous human patient urine samples (N = 56), and a correlation of R2 = 0.9744 was achieved between the PS-MS results and validated clinical method results. This work demonstrates the utility of PS-MS to simultaneously quantify a large (albumin) and a small (creatinine) molecule directly in patient urine samples, and its potential as a tool for clinical albuminuria diagnostics.
Collapse
Affiliation(s)
- Igor Pereira
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada.
| | | | - Chris G Gill
- Applied Environmental Research Laboratories (AERL), Chemistry Department, Vancouver Island University, Nanaimo, BC, V9R 5S5, Canada.
- Chemistry Department, University of Victoria, Victoria, BC, V8P 5C2, Canada
- Chemistry Department, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
- Department of Occupational and Environmental Health Sciences, University of Washington, Seattle, WA, 98195-1618, USA
| |
Collapse
|
7
|
Zhang Y, Huang Y, Li Y, Zhang Z, Zuo Q, Zheng Y, Zhang Z. Influence of ZnO morphology on the capability of portable paper-based electrospray ionization mass spectrometry to determine therapeutic drugs in complex matrices. Drug Test Anal 2024. [PMID: 38192164 DOI: 10.1002/dta.3639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/17/2023] [Accepted: 12/20/2023] [Indexed: 01/10/2024]
Abstract
Adsorbents play a significant role in enhancing the analytical sensitivity of target analytes in complex samples by mitigating matrix effects. In our recent report, ZnO stood out among various adsorbents to determine target therapeutic drugs in complex biological matrices when applied for portable paper-based electrospray ionization mass spectrometry (PPESI-MS). However, the influence of the morphology of ZnO on the performance of PPESI-MS is elusive. Herein, different morphologies of ZnO particles were prepared via co-precipitation or ultrasonic methods, and their capability to determine different therapeutic drugs in serum were systemically investigated. The results demonstrated that flower-shaped ZnO gave a superior capacity, and its analysis sensitivity was 2.9-12.8-fold higher than those achieved with other ZnO morphologies. Further characterization revealed that the unique performance of flower-shaped ZnO was closely associated with its favorable desorption behavior to drugs, small spray plume, and few spray emitters at the tip of coated paper substrate. To illustrate the potential of flower-shaped ZnO, its coated paper was used as a substrate for the determination of various drugs in complex matrices such as serum, and a limit of detection as low as 2 pg mL-1 was achieved. The corresponding recoveries ranged from 93.2% to 107.2%. The developed protocol is promising in high-sensitivity analysis of target drugs in complex sample matrices.
Collapse
Affiliation(s)
- Yan Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Yajie Huang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Yun Li
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Zhiming Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Qianqian Zuo
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Yajun Zheng
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| | - Zhiping Zhang
- School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an, China
| |
Collapse
|
8
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2019-2020. MASS SPECTROMETRY REVIEWS 2022:e21806. [PMID: 36468275 DOI: 10.1002/mas.21806] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
This review is the tenth update of the original article published in 1999 on the application of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings coverage of the literature to the end of 2020. Also included are papers that describe methods appropriate to analysis by MALDI, such as sample preparation techniques, even though the ionization method is not MALDI. The review is basically divided into three sections: (1) general aspects such as theory of the MALDI process, matrices, derivatization, MALDI imaging, fragmentation, quantification and the use of arrays. (2) Applications to various structural types such as oligo- and polysaccharides, glycoproteins, glycolipids, glycosides and biopharmaceuticals, and (3) other areas such as medicine, industrial processes and glycan synthesis where MALDI is extensively used. Much of the material relating to applications is presented in tabular form. The reported work shows increasing use of incorporation of new techniques such as ion mobility and the enormous impact that MALDI imaging is having. MALDI, although invented nearly 40 years ago is still an ideal technique for carbohydrate analysis and advancements in the technique and range of applications show little sign of diminishing.
Collapse
Affiliation(s)
- David J Harvey
- Nuffield Department of Medicine, Target Discovery Institute, University of Oxford, Oxford, UK
- Department of Chemistry, University of Oxford, Oxford, Oxfordshire, United Kingdom
| |
Collapse
|
9
|
Chen W, Gao Z, Chu F, He Q, Gao Y, Liu Y, Feng H, Pan Y. Heat-Assisted Dual Neutral Spray Ionization for High-Performance Online Desalting in Mass Spectrometric Analysis. Anal Chem 2022; 94:15002-15009. [PMID: 36255385 DOI: 10.1021/acs.analchem.2c02919] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In mass spectrometry (MS), nonvolatile salts contaminate the transmission system and cause ion suppression, hampering MS analysis. When MS is combined with liquid chromatography (LC) that uses a salty mobile phase, the problems become more intractable due to long analysis time. Here, a novel heat-assisted dual neutral spray ionization (HADSI) method was developed, which projected sample solution spray and solvent spray onto a heated plate to achieve online desalting and high ionization. The experimental parameters of HADSI were optimized, which indicated that the plate temperature was crucial for ionization and desalination. Eight drug compounds dissolved in various commonly used buffers were directly analyzed using HADSI-MS, even though the concentration of PBS buffer reached 500 mmol/L. The established method showed considerable sensitivity in the positive ion mode with the limits of detection at the level of nmol/L, and good linearity (R2 > 0.99) was achieved for all the analyzed compounds. The repeatability and intra- and interday precisions of the method were evaluated, demonstrating the feasibility and reliability of the analysis of salty samples by HADSI-MS. Further, the method was demonstrated to tolerate the long-time analysis of high-salt LC eluates and the device was easy to maintain. Finally, a crude roxithromycin product was separated by LC and then analyzed by HADSI-MS, and seven unknown impurities and nine known impurities were successfully detected. Our results indicated that HADSI-MS may have potential applications in academic and industrial fields.
Collapse
Affiliation(s)
- Weiwei Chen
- Department of Chemistry, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| | - Zhan Gao
- Department of Chemistry, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| | - Fengjian Chu
- Key Laboratory of Advanced Micro/Nano Electronic Devices and Smart Systems of Zhejiang, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| | - Quan He
- Department of Chemistry, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| | - Yuanji Gao
- College of Chemistry and Materials Science, Sichuan Normal University, Chengdu, 610068Sichuan, P. R. China
| | - Yaqin Liu
- Department of Chemistry, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| | - Hongru Feng
- Department of Chemistry, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| | - Yuanjiang Pan
- Department of Chemistry, Zhejiang University, Hangzhou, 310027Zhejiang, P. R. China
| |
Collapse
|
10
|
Challen B, Cramer R. Advances in ionisation techniques for mass spectrometry-based omics research. Proteomics 2022; 22:e2100394. [PMID: 35709387 DOI: 10.1002/pmic.202100394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 06/09/2022] [Accepted: 06/10/2022] [Indexed: 11/10/2022]
Abstract
Omics analysis by mass spectrometry (MS) is a vast field, with proteomics, metabolomics and lipidomics dominating recent research by exploiting biological MS ionisation techniques. Traditional MS ionisation techniques such as electrospray ionisation have limitations in analyte-specific sensitivity, modes of sampling and throughput, leading to many researchers investigating new ionisation methods for omics research. In this review, we examine the current landscape of these new ionisation techniques, divided into the three groups of (electro)spray-based, laser-based and other miscellaneous ionisation techniques. Due to the wide range of new developments, this review can only provide a starting point for further reading on each ionisation technique, as each have unique benefits, often for specialised applications, which promise beneficial results for different areas in the omics world.
Collapse
Affiliation(s)
- Bob Challen
- Department of Chemistry, University of Reading, Whiteknights, Reading, UK
| | - Rainer Cramer
- Department of Chemistry, University of Reading, Whiteknights, Reading, UK
| |
Collapse
|
11
|
Song X, Mofidfar M, Zare RN. Introducing Nafion for In Situ Desalting and Biofluid Profiling in Spray Mass Spectrometry. Front Chem 2022; 9:807244. [PMID: 35145954 PMCID: PMC8821663 DOI: 10.3389/fchem.2021.807244] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 12/21/2021] [Indexed: 12/16/2022] Open
Abstract
We introduce Nafion into the ambient ionization technique of spray mass spectrometry to serve for in situ desalting and direct analysis of biological fluids. Nafion was coated onto the surface of the triangular spray tip as the cation exchange material. Because the sulfonic group from the Nafion membrane effectively exchanges their carried protons with inorganic salt ions (e.g., Na+ and K+), the analyte’s ionization efficiency can be significantly enhanced by reducing ion suppression. The desalting efficiency can reach 90% and the maximum tolerance of the absolute salt amount reaches 100 μmol. The mass spectral profile can also be simplified by removing the multiple adducted ion types from small-molecule drugs and metabolites ([M + Na]+ and [M + K]+), or multiply charged ions formed by proteins ([M + nNa]n+ and [M + nK]n+). Thus, the Nafion coating makes less ambiguous data interpretation collected from spray mass spectrometry for qualitative profiling or quantitative measurement of a target analyte.
Collapse
Affiliation(s)
- Xiaowei Song
- Department of Chemistry, Fudan University, Shanghai, China
- Department of Chemistry, Stanford University, Stanford, CA, United States
| | - Mohammad Mofidfar
- Department of Chemistry, Stanford University, Stanford, CA, United States
| | - Richard N. Zare
- Department of Chemistry, Stanford University, Stanford, CA, United States
- *Correspondence: Richard N. Zare,
| |
Collapse
|
12
|
Rapid differentiation of simple saccharides based on cluster ions by paper spray tandem mass spectrometry. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2022.01.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
13
|
Chiu KY, Wang Q, Gunawardena HP, Held M, Faik A, Chen H. Desalting Paper Spay Mass Spectrometry (DPS-MS) for Rapid Detection of Glycans and Glycoconjugates. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2021; 469:116688. [PMID: 35386843 PMCID: PMC8981528 DOI: 10.1016/j.ijms.2021.116688] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The detection of glycans and glycoconjugates has gained increasing attention in biological fields. Traditional mass spectrometry (MS)-based methods for glycoconjugate analysis are challenged with poor intensity when dealing with complex biological samples. We developed a desalting paper spray mass spectrometry (DPS-MS) strategy to overcome the issue of signal suppression of carbohydrates in salted buffer. Glycans and glycoconjugates (i.e., glycopeptides, nucleotide sugars, etc.) in non-volatile buffer (e.g., Tris buffer) can be loaded on the paper substrate from which buffers can be removed by washing with ACN/H2O (90/10 v/v) solution. Glycans or glycoconjugates can then be eluted and spray ionized by adding ACN/H2O/formic acid (FA) (10/90/1 v/v/v) solvent and applying a high voltage (HV) to the paper substrate. This work also showed that DPS-MS is applicable for direct detection of intact glycopeptides and nucleotide sugars as well as determination of glycosylation profiling of antibody, such as NIST monoclonal antibody IgG (NISTmAb). NISTmAb was deglycosylated with PNGase F to release N-linked oligosaccharides. Twenty-six N-linked oligosaccharides were detected by DPS-MS within a 5-minute timeframe without the need for further enrichment or derivatization. This work demonstrates that DPS-MS allows fast and sensitive detection of glycans/oligosaccharides and glycosylated species in complex matrices and has great potential in bioanalysis.
Collapse
Affiliation(s)
- Kai-Yuan Chiu
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, New Jersey, USA, 07102
| | - Qi Wang
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, New Jersey, USA, 07102
| | - Harsha P Gunawardena
- Janssen Research & Development, The Janssen Pharmaceutical Companies of Johnson & Johnson, Spring House, Pennsylvania, USA, 19477
| | - Michael Held
- Deparment of Chemistry and Biochemistry, Ohio University, Athens, Ohio 45701, USA
- Interdisciplinary Program in Molecular and Cellular Biology, Ohio University, Athens, Ohio USA, 45701
| | - Ahmed Faik
- Interdisciplinary Program in Molecular and Cellular Biology, Ohio University, Athens, Ohio USA, 45701
- Department of Environmental and Plant Biology, Ohio University, Athens Ohio, USA, 45701
| | - Hao Chen
- Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, New Jersey, USA, 07102
| |
Collapse
|
14
|
Song X, Li J, Mofidfar M, Zare RN. Distinguishing between Isobaric Ions Using Microdroplet Hydrogen-Deuterium Exchange Mass Spectrometry. Metabolites 2021; 11:728. [PMID: 34822386 PMCID: PMC8625015 DOI: 10.3390/metabo11110728] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 10/21/2021] [Accepted: 10/22/2021] [Indexed: 11/16/2022] Open
Abstract
Isobaric ions having the same mass-to-charge ratio cannot be separately identified by mass spectrometry (MS) alone, but this limitation can be overcome by using hydrogen-deuterium exchange (HDX) in microdroplets. Because isobaric ions may contain a varied number of exchangeable sites and different types of functional groups, each one produces a unique MS spectral pattern after droplet spray HDX without the need for MS/MS experiments or introduction of ion mobility measurements. As an example of the power of this approach, isobaric ions in urinary metabolic profiles are identified and used to distinguish between healthy individuals and those having bladder cancer.
Collapse
Affiliation(s)
- Xiaowei Song
- Department of Chemistry, Stanford University, Stanford, CA 94305, USA; (X.S.); (M.M.)
- Department of Chemistry, Fudan University, Shanghai 200438, China;
| | - Jia Li
- Department of Chemistry, Fudan University, Shanghai 200438, China;
| | - Mohammad Mofidfar
- Department of Chemistry, Stanford University, Stanford, CA 94305, USA; (X.S.); (M.M.)
| | - Richard N. Zare
- Department of Chemistry, Stanford University, Stanford, CA 94305, USA; (X.S.); (M.M.)
| |
Collapse
|