1
|
Che S, Konno H, Makabe K. SpyTag Peptide with Alkoxyl Aspartic Acids for pH-Dependent Activation of the SpyCatcher/Tag System. Bioconjug Chem 2024; 35:616-622. [PMID: 38664897 DOI: 10.1021/acs.bioconjchem.4c00052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
The SpyCatcher/SpyTag system is a protein pair that forms a covalent isopeptide bond without an additional energy supply. The ability to connect fused proteins makes this system an attractive tool for several protein engineering applications. Conditional activation of the SpyCatcher/SpyTag complex formation further expands the use of this system. Here, we evaluated the pH activation of SpyTag using alkoxyaspartic acids in the isopeptide-forming residue. We found that a peptide with an ethoxy group can be activated by hydrolysis under high pH conditions. However, the hydrolysis induces isoaspartate (isoAsp) formation, which is confirmed by an isoAsp-inserted short peptide. We overcame this problem by changing the C-terminal side of the aspartic acid position to Pro, which does not form isoAsp under high pH conditions. The findings of this study provide fundamental knowledge of the synthetic construction of the modified SpyTag peptide.
Collapse
Affiliation(s)
- Sonji Che
- Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jyonan, Yonezawa, Yamagata 992-8510, Japan
| | - Hiroyuki Konno
- Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jyonan, Yonezawa, Yamagata 992-8510, Japan
| | - Koki Makabe
- Graduate School of Science and Engineering, Yamagata University, 4-3-16 Jyonan, Yonezawa, Yamagata 992-8510, Japan
| |
Collapse
|
2
|
Wu HT, Van Orman BL, Julian RR. Localizing Isomerized Residue Sites in Peptides with Tandem Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:705-713. [PMID: 38440975 PMCID: PMC10995990 DOI: 10.1021/jasms.3c00373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/22/2024] [Accepted: 02/26/2024] [Indexed: 03/06/2024]
Abstract
Isomerized amino acid residues have been identified in many peptides extracted from tissues or excretions of humans and animals. These isomerized residues can play key roles by affecting biological activity or by exerting an influence on the process of aging. Isomerization occurs spontaneously and does not result in a mass shift. Thus, identifying and localizing isomerized residues in biological samples is challenging. Herein, we introduce a fast and efficient method using tandem mass spectrometry (MS) to locate isomerized residues in peptides. Although MS2 spectra are useful for identifying peptides that contain an isomerized residue, they cannot reliably localize isomerization sites. We show that this limitation can be overcome by utilizing MS3 experiments to further evaluate each fragment ion from the MS2 stage. Comparison at the MS3 level, utilizing statistical analyses, reveals which MS2 fragments differ between samples and, therefore, must contain the isomerized sites. The approach is similar to previous work relying on ion mobility to discriminate MS2 product ions by collision cross-section. The MS3 approach can be implemented using either ion-trap or beam-type collisional activation and is compatible with the quantification of isomer mixtures when coupled to a calibration curve. The method can also be implemented in combination with liquid chromatography in a targeted approach. Enabling the identification and localization of isomerized residues in peptides with an MS-only methodology will expand accessibility to this important information.
Collapse
Affiliation(s)
- Hoi-Ting Wu
- Department of Chemistry, University of California, Riverside, California 92521, United States
| | - Brielle L. Van Orman
- Department of Chemistry, University of California, Riverside, California 92521, United States
| | - Ryan R. Julian
- Department of Chemistry, University of California, Riverside, California 92521, United States
| |
Collapse
|
3
|
Miyagi M, Kiesel E, Neumbo K, Nakazawa T. Deuterium Labeling of Isoaspartic and Isoglutamic Acids for Mass Spectrometry Analysis. Anal Chem 2024; 96:3077-3086. [PMID: 38344941 PMCID: PMC10984558 DOI: 10.1021/acs.analchem.3c05194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/31/2024] [Accepted: 02/02/2024] [Indexed: 04/02/2024]
Abstract
Isoaspartic acid (isoAsp) is a common protein modification that spontaneously arises from asparagine or aspartic acid and has been linked to various diseases and health conditions. However, current methods for identifying isoAsp sites in proteins often suffer from ambiguity and have not gained widespread adoption. We developed a novel method that exclusively labels isoAsp with deuterium. This method capitalizes on the unique structural characteristics of isoAsp residues, which possess a free α-carboxyl group and can form an oxazolone ring. Once the oxazolone ring forms, it facilitates racemization at the Cα-position, incorporating a deuteron from a D2O solvent. The sites of deuterium-incorporated isoAsp in proteins can be unequivocally determined by comparing the precursor and product ion masses of the peptides from proteins reacted in H2O and D2O. The effectiveness of this method has been demonstrated through its application to model proteins lysozyme and rituximab. Furthermore, we have confirmed that the isoAsp deuterium-labeling reaction efficiently labels both l- and d-isoAsp without distinction, as well as isoglutamic acid (isoGlu), for which no effective detection methods currently exist.
Collapse
Affiliation(s)
- Masaru Miyagi
- Department
of Pharmacology, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106-4988, United States
| | - Evan Kiesel
- Department
of Pharmacology, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106-4988, United States
| | - Kelao Neumbo
- Department
of Pharmacology, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106-4988, United States
| | - Takashi Nakazawa
- Department
of Chemistry, Nara Women’s University, Nara 630-8506, Japan
| |
Collapse
|
4
|
Abdulbagi M, Di B, Li B. Resolving D-Amino Acid Containing Peptides Using Ion Mobility-Mass Spectrometry: Challenges and Recent Developments. Crit Rev Anal Chem 2023:1-10. [PMID: 37975700 DOI: 10.1080/10408347.2023.2282510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Peptides and proteins having D-amino acids in their sequences are now believed to be widespread among different living organisms. Their significance is attributed to the diverse functions of these molecules, such as having a certain pathological implication or enhancing biological activity. Indeed, some peptide molecules with D-amino acids in their structure have already found their way to clinical use such as the antibacterial gramicidin and the antidiabetic nateglinide. Ion mobility mass spectrometry (IM-MS) added an additional dimension of separation as it depends on ions mobility in the space, which is dependent on their shapes, and the shape depends on the orientation of atoms. Thus, D-amino acids containing peptides (DAACPs) will have different mobility and collision cross-section values than those with L-amino acids. Eventually, this will lead to baseline separation of the two peptides. Additionally, ion mobility can precisely locate the position of D-amino acids by analyzing the difference in the arrival times of the fragment ions. The importance of DAACPs, as well as the difficulties in discovering them, were addressed in this review. Similarly, we emphasized how recent developments in IM-MS have improved their detection and analysis. Consequently, the LC-IM-MS/MS platform appears to be promising in isomeric mixture analysis.
Collapse
Affiliation(s)
- Mohamed Abdulbagi
- Center Key Laboratory on Protein Chemistry and Structural Biology, China Pharmaceutical University, Nanjing, China
| | - Bin Di
- Center Key Laboratory on Protein Chemistry and Structural Biology, China Pharmaceutical University, Nanjing, China
- Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Nanjing, China
- Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing, China
| | - Bo Li
- Center Key Laboratory on Protein Chemistry and Structural Biology, China Pharmaceutical University, Nanjing, China
- Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, Nanjing, China
- Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing, China
| |
Collapse
|
5
|
Nagy K, Gellén G, Papp D, Schlosser G, Révész Á. Optimum collision energies for proteomics: The impact of ion mobility separation. JOURNAL OF MASS SPECTROMETRY : JMS 2023; 58:e4957. [PMID: 37415399 DOI: 10.1002/jms.4957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 05/28/2023] [Accepted: 06/19/2023] [Indexed: 07/08/2023]
Abstract
Ion mobility spectrometry (IMS) is a widespread separation technique used in various research fields. It can be coupled to liquid chromatography-mass spectrometry (LC-MS/MS) methods providing an additional separation dimension. During IMS, ions are subjected to multiple collisions with buffer gas, which may cause significant ion heating. The present project addresses this phenomenon from the bottom-up proteomics point of view. We performed LC-MS/MS measurements on a cyclic ion mobility mass spectrometer with varied collision energy (CE) settings both with and without IMS. We investigated the CE dependence of identification score, using Byonic search engine, for more than 1000 tryptic peptides from HeLa digest standard. We determined the optimal CE values-giving the highest identification score-for both setups (i.e., with and without IMS). Results show that lower CE is advantageous when IMS separation is applied, by 6.3 V on average. This value belongs to the one-cycle separation configuration, and multiple cycles may supposedly have even larger impact. The effect of IMS is also reflected in the trends of optimal CE values versus m/z functions. The parameters suggested by the manufacturer were found to be almost optimal for the setup without IMS; on the other hand, they are obviously too high with IMS. Practical consideration on setting up a mass spectrometric platform hyphenated to IMS is also presented. Furthermore, the two CID (collision induced dissociation) fragmentation cells of the instrument-located before and after the IMS cell-were also compared, and we found that CE adjustment is needed when the trap cell is used for activation instead of the transfer cell. Data have been deposited in the MassIVE repository (MSV000090944).
Collapse
Affiliation(s)
- Kinga Nagy
- MS Proteomics Research Group, Research Centre for Natural Sciences, Budapest, H-1117, Hungary
- Hevesy György PhD School of Chemistry, Faculty of Science, Institute of Chemistry, Eötvös Loránd University, Budapest, H-1117, Hungary
| | - Gabriella Gellén
- MTA-ELTE Lendület Ion Mobility Mass Spectrometry Research Group, Faculty of Science, Institute of Chemistry, Eötvös Loránd University, Budapest, H-1117, Hungary
| | - Dávid Papp
- Hevesy György PhD School of Chemistry, Faculty of Science, Institute of Chemistry, Eötvös Loránd University, Budapest, H-1117, Hungary
- MTA-ELTE Lendület Ion Mobility Mass Spectrometry Research Group, Faculty of Science, Institute of Chemistry, Eötvös Loránd University, Budapest, H-1117, Hungary
| | - Gitta Schlosser
- MTA-ELTE Lendület Ion Mobility Mass Spectrometry Research Group, Faculty of Science, Institute of Chemistry, Eötvös Loránd University, Budapest, H-1117, Hungary
| | - Ágnes Révész
- MS Proteomics Research Group, Research Centre for Natural Sciences, Budapest, H-1117, Hungary
| |
Collapse
|
6
|
Bashyal A, Hui JO, Flick T, Dykstra AB, Zhang Q, Campuzano IDG, Brodbelt JS. Differentiation of Aspartic and Isoaspartic Acid Using 193 nm Ultraviolet Photodissociation Mass Spectrometry. Anal Chem 2023; 95:11510-11517. [PMID: 37458293 PMCID: PMC10588209 DOI: 10.1021/acs.analchem.3c02025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Spontaneous conversion of aspartic acid (Asp) to isoaspartic acid (isoAsp) is a ubiquitous modification that influences the structure and function of proteins. This modification of Asp impacts the stability of biotherapeutics and has been linked to the development of neurodegenerative diseases. We explored the use of 193 nm ultraviolet photodissociation (UVPD) to distinguish Asp and isoAsp in the protonated and deprotonated peptides. The differences in the relative abundances of several fragment ions uniquely generated by UVPD were used to differentiate isomeric peptide standards containing Asp or isoAsp. These fragment ions result from the cleavage of bonds N-terminal to Asp/isoAsp residues in addition to the side-chain losses from Asp/isoAsp or the losses of COOH, CO2, CO, or H2O from y-ions. Fragmentation of Asp-containing tryptic peptides using UVPD resulted in more enhanced w/w + 1/y - 1/x ions, while isoAsp-containing peptides yielded more enhanced y - 18/y - 45/y - 46 ions. UVPD was also used to identify an isomerized peptide from a tryptic digest of a monoclonal antibody. Moreover, UVPD of a protonated nontryptic peptide resulted in more enhanced y ions N- and C-terminal to isoAsp and differences in b/y ion ratios that were used to identify the isoAsp peptide.
Collapse
Affiliation(s)
- Aarti Bashyal
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| | - John O Hui
- Amgen Research, Molecular Analytics, Amgen Inc., Thousand Oaks, California 91320, United States
| | - Tawnya Flick
- Process Development, Attribute Sciences, Amgen Inc., Thousand Oaks, California 91320, United States
| | - Andrew B Dykstra
- Process Development, Attribute Sciences, Amgen Inc., Thousand Oaks, California 91320, United States
| | - Qingchun Zhang
- Process Development, Attribute Sciences, Amgen Inc., Thousand Oaks, California 91320, United States
| | - Iain D G Campuzano
- Amgen Research, Molecular Analytics, Amgen Inc., Thousand Oaks, California 91320, United States
| | - Jennifer S Brodbelt
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
7
|
High-end ion mobility mass spectrometry: A current review of analytical capacity in omics applications and structural investigations. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116761] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|