1
|
Dorshow RB, Debreczeny MP, Goldstein SL, Shieh JJ. Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102). Kidney Int 2024:S0085-2538(24)00455-1. [PMID: 38964736 DOI: 10.1016/j.kint.2024.06.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 05/20/2024] [Accepted: 06/17/2024] [Indexed: 07/06/2024]
Abstract
The fluorescent compound relmapirazin has been rationally designed for use in point-of-care measurement of glomerular filtration rate (GFR), with attributes including negligible protein binding, negligible metabolites in vivo, negligible tubular secretion, and excellent chemical and photo stability. Twenty-four nonclinical assays were performed in accordance with FDA requirements yielding negligible toxicology concerns. Here, a clinical study was performed to validate relmapirazin as a GFR tracer in patients by comparison to iohexol. This was evaluated in 120 adults at three clinical sites with eGFR values ranging from normal to Stage 4 chronic kidney disease. Relmapirazin and iohexol were administered intravenously in consecutive boluses to each subject and serial blood samples obtained over the subsequent 12 hours. Plasma concentrations were measured and the corresponding plasma GFR for each agent was determined using a standard two-compartment pharmacokinetic assessment. Urine from each subject was collected for the entire 12-hour study period to measure the amount of administered dose appearing in the urine. A near perfect linear regression correlation was observed between the GFRs measured by these two tracers (r2=0.99). Bland-Altman analysis confirmed agreement between these two measures of GFR (limits of agreement -7.0 to +5.6 mL/min; mean of -0.7 mL/min). The GFR determined by relmapirazin was independent of GFR stratification by chronic kidney disease stage, and importantly by race. The percent of the administered relmapirazin dose recovered in the urine was greater than or equal to that of iohexol with no reported severe adverse events. Thus, relmapirazin may be used as a GFR tracer agent in humans.
Collapse
|
2
|
Shieh JJ, Riley IR, Rogers TE, Dorshow RB. Novel Chiral High-Performance Liquid Chromatographic (HPLC) Determination of MB-102, A New Fluorescent Tracer Agent Enabling the Measurement of Point-of-Care Glomerular Filtration Rate. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2102645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
|
3
|
Bugaj JE, Dorshow RB. Evaluation of Developmental and Reproductive Toxicity in Rabbits for MB-102, a Fluorescent Tracer Agent Designed for Real-Time Measurement of Glomerular Filtration Rate. Int J Toxicol 2022; 41:380-388. [PMID: 35758830 DOI: 10.1177/10915818221111331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The fluorescent tracer, MB-102, has been designed for the direct, real-time measurement of glomerular filtration rate. Previous studies, both in vitro and in vivo (rats, rabbits and dogs), were conducted to assess potential toxicity including single dose toxicity, mutation assay, chromosomal aberration assay, phototoxicity, local tolerance study, micronuclease assay, hERG channel changes, CNS and cardiovascular safety. The results of these studies led to a safety/toxicology profile for this agent deemed sufficient by the FDA to conduct Phase I and Phase II human clinical studies. In this paper we report on maternal toxicity and the potential effects on embryo-fetal development and the toxicokinetics of MB-102 administered daily via intravenous (bolus) injection into pregnant rabbits during the period of organogenesis gestation day 7-19. Assessment of toxicity was based on mortality, clinical observations, body weight, food consumption, reproductive performance and necropsy and cesarean section findings. Blood samples were collected for toxicokinetic evaluation. No test article findings were noted in any of these studies. The only clinical findings observed were the discoloration of skin, eyes or pelage in the 2 higher dose groups, which were considered related to the color and fluorescent properties of MB-102 and were deemed non-adverse. Exposure, as assessed by Cmax and AUC(0-6) increased in a dose dependent manner from 4.5 to 113 mg/kg/day. No accumulation of the test article was noted after multiple doses were administered. Thus, intravenous administration of MB-102 was not associated with any adverse developmental or reproductive toxicities in pregnant rabbits.
Collapse
|
4
|
Bugaj JE, Dorshow RB. Absence of developmental or reproductive toxicity in rats for MB-102, a fluorescent tracer agent for point-of-care measurement of glomerular filtration rate. Regul Toxicol Pharmacol 2022; 131:105158. [DOI: 10.1016/j.yrtph.2022.105158] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 02/13/2022] [Accepted: 03/10/2022] [Indexed: 10/18/2022]
|
5
|
Sukanya P, Reddy CVR. Structural investigation, DNA interactions and in vitro anticancer studies of transition metal complexes of 3-(2-(2, 4-dihydroxy benzylidene) hydrazinyl) quinoxalin-2(1H) -one. J Biomol Struct Dyn 2021; 40:6151-6162. [PMID: 33512301 DOI: 10.1080/07391102.2021.1877819] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The Schiff base ligand, 3-(2-(2, 4-dihydroxybenzylidene) hydrazinyl) quinoxalin-2(1H)-one (RHQO) has been synthesized and characterized by spectral and single crystal X-ray analysis. The Mn(II), Ni(II) and Cu(II) complexes of RHQO have been synthesized and characterized by FT-IR, UV-VIS, mass, EPR spectra, CHN, thermo gravimetric analysis, magnetic susceptibility and conductivity measurements. The morphology of the ligand and complexes is studied by Scanning Electron Microscopy. The metal complexes formed were found to be polymeric in nature. The abilities of the ligand and its metal complexes to interact and bind with calf thymus DNA (CT-DNA) has been studied by electronic absorption spectroscopy and their quantitative binding strength was evaluated in terms of their intrinsic binding constant (Kb). The cleavage interaction of the ligand and its metal complexes with super coiled pBR 322 DNA has been investigated by agarose gel electrophoresis. Cytotoxicity of the Cu(II) and Ni(II) complexes was evaluated using various cancer cell lines, Human cervical cancer cell line (Hela), B16 melanoma F10(B16-F10), Human ovarian cancer cell (SKOV3) and Breast cancer cell line (MCF7) by MTT assay. The results indicated that the ligand and its metal complexes bind with CT-DNA by groove binding mode and cleaved the supercoiled pBR 322 DNA in to nicked form. The Ni(II) and Cu(II) complexes exhibited anticancer activity without affecting the normal CHO-K1 cell lines. Communicated by Vsevolod Makeev.
Collapse
Affiliation(s)
- Panaganti Sukanya
- Department of Chemistry, Vasavi College of Engineering, Hyderabad, India.,Department of Chemistry, Jawaharlal Nehru Technological University Hyderabad, Hyderabad, India
| | | |
Collapse
|
6
|
Singh D, Aggarwal S, Singh VK, Pratap R, Mishra AK, Tiwari AK. Lanthanide (Ln 3+) complexes of bifunctional chelate: Synthesis, physicochemical study and interaction with human serum albumin (HSA). SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 244:118808. [PMID: 32846304 DOI: 10.1016/j.saa.2020.118808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 07/21/2020] [Accepted: 08/03/2020] [Indexed: 06/11/2023]
Abstract
Bifunctional chelate EDTA-bis amide (N,N'-bis (tyramide)ethylenediamine-N,N'-diacetic acid) that has ability to mimic natural amino acids was synthesized and analyzed by various spectroscopic techniques. The physicochemical studies were performed to calculate the various thermodynamic and kinetic parameters for the synthesized poly-amino carboxylate ligand. The two protonation constant (pka's = 3.460 and 6.722) of the prepared ligand and stability constants (log KML's = 15.8, 18.1, 16.2, 18.4, 17.5, 18.9, 13.6 and 12.8) of the complexes formed with Ce3+, Sm3+, Eu3+, Gd3+, Tb3+, Lu3+, Zn2+ and Cu2+ were determined by potentiometric titration using 0.1 M Me4NOH as non-aqueous base. The formation kinetics of [EuEDTA-TA2]+ and [CeEDTA-TA2]+ was studied and the rate constants were found to be 2.95 × 10-5 s-1 and 4.414 × 10-5 s-1respectively including the exchange reaction of [EuEDTA-TA2]+ with Zn2+ and Cu2+ spectrophotometrically. The Eu(III) complex of EDTA(TA)2 gives three emission bands at 480 nm, 540 nm and 610 nm (λmax = 270 nm, excitation) which shows efficacy of the ligand as an optical imaging agent. Molecular docking studies with Human Serum Albumin (HSA: PDB 1E78) showed binding pattern with the residues Arg218, Arg222, Lys195 and Lys444 in sub domain II A of site I via hydrogen bond and identifies the ligand-HSA interaction and specific insight for transportation to the target sites. Subsequently, fluorescence spectroscopy was performed at λex = 350 nm binding constant for HSA was 5.847 × 104 M-1 which showed effective quenching effect.
Collapse
Affiliation(s)
- Deepika Singh
- Department of Chemistry, Babasaheb Bhimrao Ambedkar University (A Central University), Lucknow, Lucknow, India
| | - Swati Aggarwal
- Institute of Nuclear Medicine and Allied Sciences, DRDO, Timarpur, New Delhi, India; Department of Chemistry, University of Delhi, New Delhi, India; Kalindi College, Department of Chemistry, University of Delhi, New Delhi, India
| | | | - Ramendra Pratap
- Department of Chemistry, University of Delhi, New Delhi, India
| | - Anil Kumar Mishra
- Institute of Nuclear Medicine and Allied Sciences, DRDO, Timarpur, New Delhi, India
| | - Anjani Kumar Tiwari
- Institute of Nuclear Medicine and Allied Sciences, DRDO, Timarpur, New Delhi, India; Department of Chemistry, Babasaheb Bhimrao Ambedkar University (A Central University), Lucknow, Lucknow, India.
| |
Collapse
|
7
|
Shieh JJ, Riley IR, Rogers TE, Kao LF, Dorshow RB. Characterization of MB-102, a New Fluorescent Tracer Agent for Point-of-Care Renal Function Monitoring. J Pharm Sci 2020; 109:1191-1198. [DOI: 10.1016/j.xphs.2019.11.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 10/13/2019] [Accepted: 11/01/2019] [Indexed: 10/25/2022]
|
8
|
Next tier in vitro and in vivo nonclinical studies further elucidating the safety and toxicity profile of MB-102, a novel fluorescent tracer agent for measurement of glomerular filtration rate. Regul Toxicol Pharmacol 2019; 107:104417. [DOI: 10.1016/j.yrtph.2019.104417] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Revised: 06/14/2019] [Accepted: 07/01/2019] [Indexed: 11/18/2022]
|
9
|
Huang J, Gretz N. Light-Emitting Agents for Noninvasive Assessment of Kidney Function. ChemistryOpen 2017; 6:456-471. [PMID: 28794936 PMCID: PMC5542756 DOI: 10.1002/open.201700065] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Indexed: 02/03/2023] Open
Abstract
The noninvasive assessment of kidney function and diagnosis of kidney disease have long been challenges. Traditional methods are not routinely available, because the existing protocols are cumbersome, time consuming, and invasive. In the past few years, significant progress in the area of diagnosing kidney function and disease on the basis of light-emitting agents has been made. Herein, we briefly review light-emitting agents, including organic fluorescent agents and inorganic renal clearable luminescent nanoparticles for the noninvasive and real-time monitoring of kidney function and disease. Moreover, some significant requirements and strategies regarding the design of ideal glomerular filtration rate agents and renal clearable nanoparticles are discussed. Finally, we discuss future challenges in expediting clinical translation of these developed light-emitting agents, along with considerations of the efforts that need to be made to develop new agents and diagnosing kidney disease.
Collapse
Affiliation(s)
- Jiaguo Huang
- Medical Research Center, Medical Faculty MannheimUniversity of HeidelbergTheodor-Kutzer-Ufer 1–368167MannheimGermany
| | - Norbert Gretz
- Medical Research Center, Medical Faculty MannheimUniversity of HeidelbergTheodor-Kutzer-Ufer 1–368167MannheimGermany
| |
Collapse
|
10
|
Moggio A, Geraci S, Boido A, Sticht C, Gretz N, Bussolati B. Assessment of acute kidney injury in rhabdomyolytic mice by transcutaneous measurement of sinistrin excretion. Nephrol Dial Transplant 2017; 32:1167-1175. [DOI: 10.1093/ndt/gfw438] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023] Open
|
11
|
Huang J, Weinfurter S, Pinto PC, Pretze M, Kränzlin B, Pill J, Federica R, Perciaccante R, Ciana LD, Masereeuw R, Gretz N. Fluorescently Labeled Cyclodextrin Derivatives as Exogenous Markers for Real-Time Transcutaneous Measurement of Renal Function. Bioconjug Chem 2016; 27:2513-2526. [DOI: 10.1021/acs.bioconjchem.6b00452] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Jiaguo Huang
- Medical
Research Center, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Stefanie Weinfurter
- Medical
Research Center, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Pedro Caetano Pinto
- Division
of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, 3584 CG Utrecht, The Netherlands
| | - Marc Pretze
- Molecular
Imaging and Radiochemistry, Department of Clinical Radiology and Nuclear
Medicine, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Bettina Kränzlin
- Medical
Research Center, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | - Johannes Pill
- Medical
Research Center, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| | | | | | | | - Rosalinde Masereeuw
- Division
of Pharmacology, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, 3584 CG Utrecht, The Netherlands
| | - Norbert Gretz
- Medical
Research Center, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany
| |
Collapse
|
12
|
Improved kinetic model for the transcutaneous measurement of glomerular filtration rate in experimental animals. Kidney Int 2016; 90:1377-1385. [PMID: 27665115 DOI: 10.1016/j.kint.2016.07.024] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Revised: 07/13/2016] [Accepted: 07/14/2016] [Indexed: 02/06/2023]
Abstract
Transcutaneous measurement of the glomerular filtration rate (tGFR) is now frequently used in animal studies. tGFR allows consecutive measurements on the same animal, including multiple measurements on a daily basis, because no blood sampling is required. Here we derive and validate a novel kinetic model for the description of transcutaneously measured FITC-Sinistrin excretion kinetics. In contrast to standard 1- to 3-compartment models, our model covers the complete kinetic, including injection and distribution of the tracer in the plasma compartment. Because the model describes the complete progression of the measurement, it allows further refinement by correcting for baseline shifts observed occasionally during measurement. Possible reasons for shifts in the background signal include photo bleaching of the skin, autofluorescence, changes of physiological state of the animals during the measurements, or effects arising from the attachment of the measurement device. Using the new 3-compartment kinetic model with modulated baseline (tGFR3cp.b.m), tGFR measurements in rats can reach comparable precision as those from GFR measurements assessed using a gold standard technique based on constant infusion of a tracer. Moreover, the variability of simultaneous (parallel) measurements, as well as repeated tGFR measurements in the same animals, showed higher precision when tGFR3cp.b.m was compared with the 1-compartment tGFR1cp model.
Collapse
|
13
|
Carrara F, Azzollini N, Nattino G, Corna D, Villa S, Cerullo D, Zoja C, Abrante B, Luis-Lima S, Porrini E, Cannata A, Ferrari S, Fois M, Stucchi N, Gaspari F. Simplified Method to Measure Glomerular Filtration Rate by Iohexol Plasma Clearance in Conscious Rats. Nephron Clin Pract 2016; 133:62-70. [DOI: 10.1159/000445843] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 03/23/2016] [Indexed: 11/19/2022] Open
|
14
|
Bugaj JE, Dorshow RB. Pre-clinical toxicity evaluation of MB-102, a novel fluorescent tracer agent for real-time measurement of glomerular filtration rate. Regul Toxicol Pharmacol 2015; 72:26-38. [DOI: 10.1016/j.yrtph.2015.02.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Revised: 01/09/2015] [Accepted: 02/20/2015] [Indexed: 01/07/2023]
|
15
|
Steinbach S, Krolop N, Strommer S, Herrera-Pérez Z, Geraci S, Friedemann J, Gretz N, Neiger R. A pilot study to assess the feasibility of transcutaneous glomerular filtration rate measurement using fluorescence-labelled sinistrin in dogs and cats. PLoS One 2014; 9:e111734. [PMID: 25423195 PMCID: PMC4244090 DOI: 10.1371/journal.pone.0111734] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Accepted: 10/07/2014] [Indexed: 01/14/2023] Open
Abstract
In dogs and cats an assessment of renal function is often needed, however, existing methods including urine and plasma clearances are invasive, cumbersome and time consuming. This pilot study evaluated the feasibility of a transcutaneous glomerular filtration rate (GFR) measurement in dogs and cats. Additionally the optimal dose and location for the transcutaneous measurement device were investigated. Renal elimination of fluorescein-isothiocyanate-labelled sinistrin (FITC-S) was measured transcutaneously for 4 hours. The procedures were performed in awake, freely moving animals using escalating doses of FITC-S (10 mg/kg, 30 mg/kg, 50 mg/kg) with a wash-out period of at least 24 h in between. Multiple devices were placed on each animal. The resulting FITC-S disappearance curves were visually assessed to determine the most suitable location and the appropriate dose to reach an adequate transcutaneous peak signal for kinetic analysis. In both species 30 mg/kg were adequate for kinetic calculation. The most suitable place for the device was the lateral thoracic wall in dogs and the ventral abdominal wall in cats, respectively. Transcutaneous FITC-S clearance was then repeated using the optimal dose and location and in parallel with an additional plasma sinistrin clearance. Plasma elimination half-lives [min] were 26, 31 and 35, and corresponding transcutaneous elimination half-lives [min] were 26, 34 and 55, respectively in the dogs. Plasma elimination half-lives [min] were 51, 60 and 61, and corresponding transcutaneous elimination half-lives [min] were 75, 96 and 83, respectively in the cats. In conclusion, transcutaneous FITC-S clearance is a feasible method for the assessment of GFR in awake dogs and cats. It is noninvasive, well tolerated and easy to perform even in a clinical setting with results being readily available. A dose of 30 mg/kg of FITC-S seems adequate for kinetic assessment. Further studies are now needed to establish reference values and evaluate transcutaneous renal clearance in various conditions.
Collapse
Affiliation(s)
- Sarah Steinbach
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
- * E-mail:
| | - Nora Krolop
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
| | - Sellyn Strommer
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
| | | | - Stefania Geraci
- Medical Research Center, University of Heidelberg, Mannheim, Germany
| | - Jochen Friedemann
- Medical Research Center, University of Heidelberg, Mannheim, Germany
| | - Norbert Gretz
- Medical Research Center, University of Heidelberg, Mannheim, Germany
| | - Reto Neiger
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
| |
Collapse
|
16
|
Measuring renal function in critically ill patients: tools and strategies for assessing glomerular filtration rate. Curr Opin Crit Care 2014; 19:560-6. [PMID: 24240821 DOI: 10.1097/mcc.0000000000000025] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
PURPOSE OF REVIEW Alterations in kidney function are common in critically ill patients and are generally assessed by changes in serum creatinine (sCr) or urine output, which are considered surrogates for glomerular filtration rate (GFR) but do not reflect the overall kidney function. There is a great need for more reliable measurements of glomerular filtration in order to guide diagnosis and therapy for acute kidney injury. In this review, we will focus on recent advances to measure GFR that could help to better evaluate kidney function and improve patient care. RECENT FINDINGS Standardized assays for sCr measurements, the use of a more precise scale with more frequent measurements, and the interpretation of the results based on patient's characteristics can increase the clinical value of sCr. New endogenous and exogenous markers will provide a more precise estimation. Imaging techniques are being developed and will probably be available in the near future. New gold standards for glomerular filtration will help in the development and improvement in the use of new biomarkers of kidney injury.
Collapse
|
17
|
Reliability of transcutaneous measurement of renal function in various strains of conscious mice. PLoS One 2013; 8:e71519. [PMID: 23977062 PMCID: PMC3747225 DOI: 10.1371/journal.pone.0071519] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2013] [Accepted: 07/01/2013] [Indexed: 11/19/2022] Open
Abstract
Measuring renal function in laboratory animals using blood and/or urine sampling is not only labor-intensive but puts also a strain on the animal. Several approaches for fluorescence based transcutaneous measurement of the glomerular filtration rate (GFR) in laboratory animals have been developed. They allow the measurement of GFR based on the elimination kinetics of fluorescent exogenous markers. None of the studies dealt with the reproducibility of the measurements in the same animals. Therefore, the reproducibility of a transcutaneous GFR assessment method was investigated using the fluorescent renal marker FITC-Sinistrin in conscious mice in the present study. We performed two transcutaneous GFR measurements within three days in five groups of mice (Balb/c, C57BL/6, SV129, NMRI at 3–4 months of age, and a group of 24 months old C57BL/6). Data were evaluated regarding day-to-day reproducibility as well as intra- and inter-strain variability of GFR and the impact of age on these parameters. No significant differences between the two subsequent GFR measurements were detected. Fastest elimination for FITC-Sinistrin was detected in Balb/c with significant differences to C57BL/6 and SV129 mice. GFR decreased significantly with age in C57BL/6 mice. Evaluation of GFR in cohorts of young and old C57BL/6 mice from the same supplier showed high consistency of GFR values between groups. Our study shows that the investigated technique is a highly reproducible and reliable method for repeated GFR measurements in conscious mice. This gentle method is easily used even in old mice and can be used to monitor the age-related decline in GFR.
Collapse
|
18
|
Singh P, Kumar V, Aggarwal S, Tiwari AK, Chuttani K, Pratap R, Mishra AK. Design, synthesis, and biological evaluation of catecholamine vehicle for studying dopaminergic system. Chem Biol Drug Des 2013; 82:226-32. [PMID: 23601203 DOI: 10.1111/cbdd.12147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2012] [Revised: 02/02/2013] [Accepted: 04/15/2013] [Indexed: 11/30/2022]
Abstract
Catecholamine mimetic EDTA-bis(tyramide) was synthesized and characterized by various spectroscopic techniques (NMR, mass spectroscopy) and λem 310 nm for the excitation at 270 nm. Molecular docking studies were performed with human serum albumin (PDB 1E78), showing binding pattern with amino acid residues Arg218, Arg222, and Lys444, identifies the ligand-human serum albumin interaction for the transportation affinity of the ligand at the specific site of the target. Subsequently, binding study with human serum albumin at λex = 350 nm found to be 5.847 × 10(4) m(-1) shows effective quenching effect. Additionally, to go more insight, acetylcholinesterase binding affinity was investigated, which shows 90% binding affinity for the 10 mm concentration. IC50 value was found 18.60 μm for MAO-B inhibition. Finally, EDTA-bis(tyramide) labeled with (99m) Tc to investigate its in vivo radiopharmaceutical efficiency having 97% binding affinity with 98% radiochemical purity. In vivo studies were carried out for (99m) Tc-EDTA-bis(tyramide) included blood kinetics showed a quick wash out from the circulation via renal route, and biodistribution revealed that maximum %ID/g was found in kidney at 1 h, and its scintigraphy image shows 3.96% brain uptake with respect to whole body.
Collapse
Affiliation(s)
- Pooja Singh
- Division of Cyclotron and Radiopharmaceutical Sciences, Institute of Nuclear Medicine and Allied Sciences, Brig. S. K. Mazumdar Road, Delhi, 110054, India
| | | | | | | | | | | | | |
Collapse
|
19
|
Lanthanide(III) Complexes of Diethylenetriaminepentaacetic Acid (DTPA)-Bisamide Derivatives as Potential Agents for Bimodal (Optical/Magnetic Resonance) Imaging. Eur J Inorg Chem 2013. [DOI: 10.1002/ejic.201300196] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
20
|
Exogenous fluorescent tracer agents based on pegylated pyrazine dyes for real-time point-of-care measurement of glomerular filtration rate. Bioorg Med Chem 2012; 20:2490-7. [PMID: 22459210 DOI: 10.1016/j.bmc.2012.03.015] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2012] [Revised: 03/01/2012] [Accepted: 03/05/2012] [Indexed: 01/23/2023]
Abstract
Novel pyrazine carboxamides bearing hydrophilic poly(ethylene glycol) (PEG) moieties were designed, synthesized, and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, compounds 4d and 5c that contain about 48 ethylene oxide units in the PEG chain exhibited the most favorable physicochemical and renal clearance properties. In vitro studies show that these two compounds have low plasma protein binding, a necessary condition for renal excretion. In vivo animal model results show that 4d and 5c have a higher urine recovery of the injected dose than iothalamate (a commonly considered gold standard GFR agent). Pharmacokinetic studies show that these two compounds exhibit a plasma clearance equivalent to iothalamate, but with a faster (i.e. lower) terminal half-life than iothalamate (possibly from restricted distribution into the extracellular space due to large molecular size and hydrodynamic volume). Furthermore, the plasma clearance of 4d and 5c remained unchanged upon blockage of the tubular secretion pathway with probenecid, a necessary condition for establishment of clearance via glomerular filtration exclusively. Finally, noninvasive real-time monitoring of this class of compounds was demonstrated by pharmacokinetic clearance of 5c by optical measurements in rat model, which correlates strongly with plasma concentration of the tracer. Hence, 4d and 5c are promising candidates for translation to the clinic as exogenous fluorescent tracer agents in real-time point-of-care monitoring of GFR.
Collapse
|
21
|
Liu Z, Li B, Wang B, Yang Z, Wang Q, Li T, Qin D, Li Y, Wang M, Yan M. Magnetic nanoparticles modified with DTPA-AMC-rare earth for fluorescent and magnetic resonance dual mode imaging. Dalton Trans 2012; 41:8723-8. [DOI: 10.1039/c2dt30125c] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
22
|
Endre ZH, Pickering JW, Walker RJ. Clearance and beyond: the complementary roles of GFR measurement and injury biomarkers in acute kidney injury (AKI). Am J Physiol Renal Physiol 2011; 301:F697-707. [PMID: 21753074 DOI: 10.1152/ajprenal.00448.2010] [Citation(s) in RCA: 106] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Acute kidney injury (AKI) is a common and frequently fatal illness in critically ill patients. The reliance on daily measurements of serum creatinine as a surrogate of glomerular filtration rate (GFR) not only delays diagnosis and development of successful therapies but also hinders insight into the pathophysiology of human AKI. Measurement of GFR under non-steady-state conditions remains an elusive gold standard against which biomarkers of renal injury need to be judged. Approaches to the rapid (near real-time) measurement of GFR are explored. Even if real-time GFR was available, absent baseline information will always limit diagnosis of AKI based on GFR or serum creatinine to a detection of change. Biomarkers of renal cellular injury have provided new strategies to facilitate detection and early intervention in AKI. However, the diagnostic and predictive performance of urinary biomarkers of injury vary, depending on both the time after renal injury and on the preinjury GFR. Progress in understanding the role of each novel biomarker in the causal pathways of AKI promises to enhance their diagnostic potential. We predict that combining rapid measures of GFR with biomarkers of renal injury will yield substantive progress in the treatment of AKI.
Collapse
Affiliation(s)
- Zoltán H Endre
- Christchurch Kidney Research Group, Department of Medicine, University of Otago, Christchurch, New Zealand.
| | | | | |
Collapse
|
23
|
Rajagopalan R, Neumann WL, Poreddy AR, Fitch RM, Freskos JN, Asmelash B, Gaston KR, Galen KP, Shieh JJ, Dorshow RB. Hydrophilic pyrazine dyes as exogenous fluorescent tracer agents for real-time point-of-care measurement of glomerular filtration rate. J Med Chem 2011; 54:5048-58. [PMID: 21667980 DOI: 10.1021/jm200257k] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Various hydrophilic pyrazine-bis(carboxamides) derived from 3,5-diamino-pyrazine-2,5-dicarboxylic acid bearing neutral and anionic groups were prepared and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, the dianionic d-serine pyrazine derivatives 2d and 2j, and the neutral dihydroxypropyl 2h, exhibited favorable physicochemical and clearance properties. In vitro studies show that 2d, 2h, and 2j have low plasma protein binding, a necessary condition for renal excretion. In vivo animal model results show that these three compounds exhibit a plasma clearance equivalent to iothalamate (a commonly considered gold standard GFR agent). In addition, these compounds have a higher urine recovery compared to iothalamate. Finally, the plasma clearance of 2d, 2h, and 2j remained unchanged upon blockage of the tubular secretion pathway with probenecid, a necessary condition for establishment of clearance via glomerular filtration only. Hence, 2d, 2h, and 2j are promising candidates for translation to the clinic as exogenous fluorescent tracer agents in real-time point-of-care monitoring of GFR.
Collapse
Affiliation(s)
- Raghavan Rajagopalan
- Covidien Pharmaceuticals, 675 McDonnell Boulevard, Hazelwood, Missouri 63042, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Transcutaneous assessment of renal function in conscious rats with a device for measuring FITC-sinistrin disappearance curves. Kidney Int 2011; 79:1254-8. [DOI: 10.1038/ki.2011.31] [Citation(s) in RCA: 87] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
25
|
New considerations in the design of clinical trials of acute kidney injury. ACTA ACUST UNITED AC 2011. [DOI: 10.4155/cli.11.38] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
26
|
Chen Q, Bryant VC, Lopez H, Kelly DL, Luo X, Natarajan A. 2,3-Substituted quinoxalin-6-amine analogs as antiproliferatives: a structure-activity relationship study. Bioorg Med Chem Lett 2011; 21:1929-32. [PMID: 21376584 DOI: 10.1016/j.bmcl.2011.02.055] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2011] [Revised: 02/10/2011] [Accepted: 02/14/2011] [Indexed: 10/18/2022]
Abstract
The quinoxaline core is considered a privileged scaffold as it is found in a variety of biologically relevant molecules. Here we report the synthesis of a quinoxalin-6-amine library, screening against a panel of cancer cell lines and a structure-activity relationship (SAR). This resulted in the identification of a bisfuranylquinoxalineurea analog (7c) that has low micromolar potency against the panel of cancer cell lines. We also show that cells treated with quinoxalineurea 7c results in caspase 3/7 activation, PARP cleavage and Mcl-1 dependent apoptosis.
Collapse
Affiliation(s)
- Qianyi Chen
- Eppley Institute for Cancer Research, University of Nebraska Medical Center, Omaha, NE 68198, United States
| | | | | | | | | | | |
Collapse
|
27
|
Heller A, Rönitz O, Barkleit A, Bernhard G, Ackermann JU. Complexation of europium(III) with the zwitterionic form of amino acids studied with ultraviolet-visible and time-resolved laser-induced fluorescence spectroscopy. APPLIED SPECTROSCOPY 2010; 64:930-935. [PMID: 20719058 DOI: 10.1366/000370210792081127] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The complex formation of europium(III) with the zwitterionic form of amino acids (alanine, phenylalanine, and threonine) has been studied in aqueous solution. Measurements were performed at I = 0.1 M (NaCl/NaClO(4)), room temperature, and trace metal concentrations in the range of pH 2 to 8 using ultraviolet-visible (UV-Vis) and time-resolved laser-induced fluorescence spectroscopy (TRLFS). While complexation leads to a significant luminescence enhancement in the emission spectrum of the metal ion, absorption in the UV-Vis spectrum of the amino acid (AA) decreases. As zwitterionic species (AAH), all three ligands form weak complexes with 1:1 stoichiometry and a general formula of EuAAH(3+) with the metal. The complex stability constants were determined to be log K approximately 1 for all complexes, indicating the negligible contribution of the amino acid side chain to the complex formation reaction.
Collapse
Affiliation(s)
- Anne Heller
- Institute of Radiochemistry, Forschungszentrum Dresden-Rossendorf e. V., P.O. Box 510119, Dresden 01314, Germany.
| | | | | | | | | |
Collapse
|
28
|
Schock-Kusch D, Sadick M, Henninger N, Kraenzlin B, Claus G, Kloetzer HM, Weiss C, Pill J, Gretz N. Transcutaneous measurement of glomerular filtration rate using FITC-sinistrin in rats. Nephrol Dial Transplant 2009; 24:2997-3001. [PMID: 19461009 DOI: 10.1093/ndt/gfp225] [Citation(s) in RCA: 94] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Inulin/sinistrin (I/S) clearance is a gold standard for an accurate assessment of glomerular filtration rate (GFR). Here we describe and validate an approach for a transcutaneous determination of GFR by using fluorescein-isothiocyanate-labelled sinistrin (FITC-S) in rats. METHODS Using a small animal imager, fluorescence is measured over the depilated ear of a rat after the injection of FITC-S. The decay curve of fluorescence is used for the calculation of half-life and GFR. The thus obtained transcutaneous data were validated by simultaneously performed enzymatic and fluorometric measurements in plasma of both FITC-S and sinistrin. RESULTS The results of enzymatic sinistrin determination versus transcutaneous half-life of FITC-S or plasma fluorescence correlated well with each other (R(2) > 0.90). Furthermore, Bland-Altman analyses proved a good degree of agreement of the three methods used. The measurements performed in healthy animals as well as different models of renal failure demonstrate its appropriateness in a wide range of renal function. CONCLUSIONS The transcutaneous method described offers a precise assessment of GFR in small animals. As neither blood and/or urine sampling nor time-consuming lab work is required, GFR can be determined immediately after the clearance procedure is finished. This method, therefore, simplifies and fastens GFR determinations in small lab animals compared to conventional bolus clearance techniques based on blood sampling. A low-cost device for the measurement of transcutaneous fluorescence intensity over time is under construction.
Collapse
|