1
|
da Cruz Schaefer G, de Mattos Brose M, Herrera Becerra JR, Bernhardt Rovaris I, Peixoto da Silva Mello F, Schneck Simão B, de Faria Valle S, Poletto Ferreira M, Vieira Amorim da Costa F. Comparison of serum creatinine, point-of-care symmetric dimethylarginine and renal imaging with glomerular filtration rate measured by renal scintigraphy in healthy and early chronic kidney diseased cats. Vet Res Commun 2023; 47:1845-1859. [PMID: 37133704 DOI: 10.1007/s11259-023-10131-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 04/23/2023] [Indexed: 05/04/2023]
Abstract
The aim of this study was to evaluate routinely used tests to diagnose cats in early stages of chronic kidney disease (CKD) and to describe a model for evaluating these variables simultaneously. Apparently healthy cats were screened using serum creatinine (sCr), point-of-care symmetric dimethylarginine (POC SDMA), urinalysis, urine protein/creatinine ratio (UPC) and imaging evaluation. Those parameters were compared to glomerular filtration rate (GFR) assessed by renal scintigraphy. Forty-four cats were included and consisted of 14 (31.8%) healthy cats (absence of abnormalities in renal morphology and sCr less than 1.6 mg/dL), 20 (45.5%) cats classified as CKD I (presence of abnormalities in renal morphology and sCr less than 1.6 mg/dL) and ten (22.7%) as CKD II (sCr equal to or greater than 1.6 mg/dL, with or without abnormalities in renal morphology). A large number (40.9%) of apparently healthy cats presented reduction in GFR, which included half of CKD I patients. Point-of-care SDMA was not a good predictor for decreased GFR, nor was it correlated with the variables GFR and sCr. Glomerular filtration rate was significantly lower in CKD I and II groups in comparison with healthy cats, but there was no significant difference between the CKD I and II groups. Multivariate logistic regression model identified three variables that affected the odds of a cat having decreased GFR (< 2.5 mL/min/kg): sCr (OR = 18.3; p = 0.019; CI = 1.6-207.2), and the ultrasonographic findings 'reduced corticomedullary definition' (OR = 19.9; p = 0.022; CI = 1.6-254.0) and 'irregular contour' (OR = 65.6; p = 0.003; CI = 4.2-1038.2). Renal ultrasonography evaluation should always be considered for screening early CKD in apparently healthy cats.
Collapse
Affiliation(s)
- Gabriela da Cruz Schaefer
- Post-Graduate Program in Veterinary Science, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil.
| | - Mariana de Mattos Brose
- Hospital de Clínicas Veterinárias, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
| | - José Ricardo Herrera Becerra
- Post-Graduate Program in Veterinary Science, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
| | - Inácio Bernhardt Rovaris
- Post-Graduate Program in Veterinary Science, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
| | | | - Bianca Schneck Simão
- Post-Graduate Program in Veterinary Science, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
| | - Stella de Faria Valle
- Department of Veterinary Clinical Pathology, College of Veterinary, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
| | - Márcio Poletto Ferreira
- Department of Animal Medicine, College of Veterinary, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, RS, Brazil
| | | |
Collapse
|
2
|
Ogawa M, Nohara H, Hsu HH, Ishizaka M, Miyagawa Y, Takemura N. Association between glomerular filtration rate and plasma N-terminal pro-atrial natriuretic peptide concentration in dogs. J Small Anim Pract 2023; 64:568-573. [PMID: 37345758 DOI: 10.1111/jsap.13626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 03/16/2023] [Accepted: 04/21/2023] [Indexed: 06/23/2023]
Abstract
OBJECTIVES To investigate the association between plasma N-terminal pro-atrial natriuretic peptide concentration and glomerular filtration rate in dogs. MATERIALS AND METHODS Dogs were classified into four categories by bodyweight. Dogs were divided into four groups (Groups 1 to 4) based on glomerular filtration rate estimates using plasma iohexol clearance per bodyweight category. Generalised linear models were built to explore the relationship between plasma N-terminal pro-atrial natriuretic peptide concentration and glomerular filtration rate and the effect of confounders on plasma N-terminal pro-atrial natriuretic peptide concentration. RESULTS Fifty-three dogs were included (Group 1, 25; Group 2, seven; Group 3, five; and Group 4, 16). The medians (interquartile range) N-terminal pro-atrial natriuretic peptide concentrations for Groups 1 to 4 were 7224 pg/mL (4766 to 10,254 mg/dL), 8958 pg/mL (4935 to 11,271 mg/dL), 9280 pg/mL (9195 to 10,384 mg/dL) and 12,683 pg/mL (9133 to 19,217 mg/dL), respectively. Group 4, estimated to have the highest reduction in glomerular filtration rate, had a higher plasma N-terminal pro-atrial natriuretic peptide concentration than Groups 1 to 3. Based on the final generalised linear model, influencing factors for plasma N-terminal pro-atrial natriuretic peptide concentration were plasma iohexol clearance (-0.136; 95% confidence interval, -0.227 to -0.046) and bodyweight (-0.058; 95% confidence interval, -0.098 to -0.018). CLINICAL SIGNIFICANCE N-terminal pro-atrial natriuretic peptide concentration is associated with the glomerular filtration rate.
Collapse
Affiliation(s)
- M Ogawa
- Laboratory of Veterinary Internal Medicine II, School of Veterinary Medicine, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo, 180-8602, Japan
| | - H Nohara
- Laboratory of Veterinary Internal Medicine II, School of Veterinary Medicine, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo, 180-8602, Japan
| | - H H Hsu
- Laboratory of Veterinary Internal Medicine II, School of Veterinary Medicine, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo, 180-8602, Japan
| | - M Ishizaka
- Laboratory of Veterinary Internal Medicine II, School of Veterinary Medicine, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo, 180-8602, Japan
| | - Y Miyagawa
- Laboratory of Veterinary Internal Medicine II, School of Veterinary Medicine, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo, 180-8602, Japan
| | - N Takemura
- Laboratory of Veterinary Internal Medicine II, School of Veterinary Medicine, Nippon Veterinary and Life Science University, 1-7-1 Kyonan-cho, Musashino-shi, Tokyo, 180-8602, Japan
| |
Collapse
|
3
|
Yu L, Lacorcia L, Johnstone T. Hyperthyroid cats and their kidneys: a literature review. Aust Vet J 2022; 100:415-432. [PMID: 35711100 PMCID: PMC9543258 DOI: 10.1111/avj.13179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2022] [Revised: 04/28/2022] [Accepted: 05/01/2022] [Indexed: 11/28/2022]
Abstract
Hyperthyroidism and chronic kidney disease (CKD) are common diseases of geriatric cats, and often occur concurrently. Thus, a thorough understanding of the influence of thyroid function on renal function is of significant value for all feline practitioners. Among other effects, hyperthyroidism causes protein catabolism and increases renal blood flow and glomerular filtration rate (GFR). These effects render traditional renal markers insensitive for the detection of CKD in cats with uncontrolled hyperthyroidism. Furthermore, the development of iatrogenic hypothyroidism with over treatment of hyperthyroidism can be detrimental to renal function and may negatively affect long-term survival. This review discusses important diagnostic considerations of feline hyperthyroidism, as well as key treatment modalities, with an emphasis on the use of radioiodine and the importance of post treatment monitoring of thyroid and renal parameters. In Australia, a common curative treatment for cats with benign hyperthyroidism (i.e. thyroid hyperplasia or adenoma) is a fixed dose of orally administered radioiodine, regardless of the serum total thyroxine concentration at the time of diagnosis. This review discusses the long term outcomes of this standard of care in comparison with current, relevant research literature from around the world. Finally, this review explores the use of symmetric dimethylarginine (SDMA) in assessing renal function before and after treatment in hyperthyroid cats. SDMA correlates well with GFR and creatinine in non-hyperthyroid cats, but our understanding of its performance in hyperthyroid cats remains in its infancy.
Collapse
Affiliation(s)
- L Yu
- Veterinary Referral HospitalDandenongVictoriaAustralia
| | - L Lacorcia
- Veterinary Referral HospitalDandenongVictoriaAustralia
| | - T Johnstone
- Animal Referral Hospital, Essendon Fields72 Hargrave AvenueEssendon FieldsVictoria3041Australia
| |
Collapse
|
4
|
de Lima CS, Ferreira KRG, Borin-Crivellenti S, Maia SR, Santana AE, Crivellenti LZ. Renal Magnesium Handling: A Comparison Between Dogs With Chronic Kidney Disease and Healthy Elderly Dogs. Top Companion Anim Med 2021; 46:100588. [PMID: 34610438 DOI: 10.1016/j.tcam.2021.100588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 09/22/2021] [Accepted: 09/30/2021] [Indexed: 11/19/2022]
Abstract
Chronic kidney disease (CKD) and aging are known to possibly cause a progressive reduction in glomerular filtration rate, which may be associated with an increase in fractional excretion of electrolytes due to an adaptive response of the remaining functioning nephrons. However, the behavior of magnesium excretion has not been studied in CKD and healthy elderly dogs. The objective was to evaluate the fractional excretion of magnesium (FEMg) in dogs with (CKD) compared to healthy elderly dogs. Sixteen healthy elderly dogs and 43 dogs with CKD were divided into 3 groups (CKD 2 [n = 14], CKD 3 [n = 17], CKD 4 [n = 12]), in accordance with the current International Renal Interest Society (IRIS) criteria that were used in this study. Blood samples were obtained by jugular venipuncture and urine samples were obtained by cystocentesis. The FEMg was evaluated at a single time point in both urine and blood samples. FEMg was significantly higher in dogs with CKD compared to healthy elderly dogs, especially in advanced stages. This preliminary study demonstrates that FEMg may be altered in dogs with CKD. Further research is warranted to elucidate magnesium's potential role in cardiovascular and arterial calcification in dogs with CKD as observed in humans with CKD.
Collapse
Affiliation(s)
- Charles Silva de Lima
- Veterinary Teaching Hospital/Animal Science Graduate Program, Franca University (UNIFRAN), Franca, São Paulo, Brazil
| | | | - Sofia Borin-Crivellenti
- Graduate Program in Veterinary Science (PPGCV)/College of Veterinary Medicine (FAMEV), Federal University of Uberlândia (UFU), Uberlândia, Minas Gerais, Brazil
| | - Suellen Rodrigues Maia
- Veterinary Medicine Graduate Program/School of Veterinary Medicine and Animal Science (FMVZ), Paulista State University (UNESP), Botucatu, São Paulo, Brazil
| | | | - Leandro Zuccolotto Crivellenti
- Graduate Program in Veterinary Science (PPGCV)/College of Veterinary Medicine (FAMEV), Federal University of Uberlândia (UFU), Uberlândia, Minas Gerais, Brazil.
| |
Collapse
|
5
|
MIYAGAWA Y, AKABANE R, OGAWA M, NAGAKAWA M, MIYAKAWA H, TAKEMURA N. Serum cystatin C concentration can be used to evaluate glomerular filtration rate in small dogs. J Vet Med Sci 2021; 82:1828-1834. [PMID: 33177264 PMCID: PMC7804046 DOI: 10.1292/jvms.20-0201] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 10/13/2020] [Indexed: 11/22/2022] Open
Abstract
Serum cystatin C levels (CysC) are used in human medicine to document progressive kidney failure. Although CysC are not thought to be useful for the diagnosis of kidney dysfunction in dogs, there has been no specific consideration of body weight as a confounding issue. The aim of this study was to assess that the utility of CysC for the diagnosis of decreased glomerular filtration rate (GFR) in smaller vs. larger dogs. In clinically healthy dogs, serum creatinine (Cre) and CysC correlate directly with body weight; we found that dogs weighing <20 kg had significantly lower CysC than those weighing ≥20 kg (0.27 ± 0.07 vs. 0.34 ± 0.05 mg/l, respectively, P<0.001). In dogs weighing <20 kg, CysC had superior diagnostic accuracy for the detection of mildly decreased plasma iohexol clearance (PCio) (<1.8 ml/min/kg) compared with Cre (sensitivity 100% vs. 80.9% and specificity 100% vs. 85.7%); this was not true for dogs weighing ≥20 kg. Additionally, using a cut-off PCio of <1.8 ml/min/kg, the area under receiver-operating characteristics curve (AUC) of CysC was significantly higher than that of Cre in dogs weighing <20 kg (P<0.05); this was not true for dogs weighing ≥20 kg (P=0.695). In conclusion, CysC is a useful marker for the detection of a mild decreasing GFR compared with Cre in dogs weighing <20 kg.
Collapse
Affiliation(s)
- Yuichi MIYAGAWA
- The Laboratory of Veterinary Internal Medicine II, Nippon Veterinary and Life Science University, 1-7-1 Kyonan cho, Musashino-shi,
Tokyo 180-8602, Japan
| | - Ryota AKABANE
- The Laboratory of Veterinary Internal Medicine II, Nippon Veterinary and Life Science University, 1-7-1 Kyonan cho, Musashino-shi,
Tokyo 180-8602, Japan
| | - Mizuki OGAWA
- The Laboratory of Veterinary Internal Medicine II, Nippon Veterinary and Life Science University, 1-7-1 Kyonan cho, Musashino-shi,
Tokyo 180-8602, Japan
| | - Masayoshi NAGAKAWA
- The Laboratory of Veterinary Internal Medicine II, Nippon Veterinary and Life Science University, 1-7-1 Kyonan cho, Musashino-shi,
Tokyo 180-8602, Japan
| | - Hirosumi MIYAKAWA
- The Laboratory of Veterinary Internal Medicine II, Nippon Veterinary and Life Science University, 1-7-1 Kyonan cho, Musashino-shi,
Tokyo 180-8602, Japan
| | - Naoyuki TAKEMURA
- The Laboratory of Veterinary Internal Medicine II, Nippon Veterinary and Life Science University, 1-7-1 Kyonan cho, Musashino-shi,
Tokyo 180-8602, Japan
| |
Collapse
|
6
|
Scope A, Schwendenwein I, Stanclova G, Vobornik A, Schauberger G. Exogenous creatinine clearence indexed to body surface area allows estimation of GFR and across species comparison. Res Vet Sci 2020; 135:36-41. [PMID: 33422730 DOI: 10.1016/j.rvsc.2020.12.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 12/21/2020] [Accepted: 12/23/2020] [Indexed: 11/18/2022]
Abstract
The assessment of renal function in birds is difficult because sensitive biomarkers are lacking. Previous studies have demonstrated the feasibility of measuring the exogenous creatinine clearance in pigeons, indicating the potential use of this technique for the assessment of renal function in birds. The aim of the study was to index the exogenous creatinine elimination rate by body surface area, enabling comparison between different species. Exploratory data on common buzzards (Buteo buteo), Eurasian eagle-owls (Bubo bubo), domestic goose (Anser anser domesticus) and racing pigeons (Columba livia) were collected and indexed by body surface area. A sterile creatinine solution was administered at a dose DM = 50 mg kg-1 i.m. into the deep pectoral muscle of 52 clinically healthy birds of the four species with different body masses. The time course of the plasma creatinine concentration was measured and analyzed by a parametric pharmacokinetic Bateman model, followed by indexing the exogenous creatinine clearance (ECC) by body surface area. The exploratory ECC values for birds with a mean body mass ranging from 0.42 kg (pigeon) to 8.2 kg (goose) were between 0.4261 mL min-1 dm-2 (CI 0.3882-0.4672) and 0.8717 mL min-1 dm-2 (CI 0.8091-0.9362). ECC indexed by body surface area turned out to be independent from body mass. Resulting exploratory data covering species with different body masses are comparable with published data from very complex studies of avian renal function.
Collapse
Affiliation(s)
- Alexandra Scope
- Department for Companion Animals and Horses, University of Veterinary Medicine Vienna, Veterinärplatz 1, A 1210 Vienna, Austria.
| | - Ilse Schwendenwein
- Division of Clinical Pathology, University of Veterinary Medicine Vienna, Veterinärplatz 1, A 1210 Vienna, Austria.
| | - Gabriela Stanclova
- Department for Companion Animals and Horses, University of Veterinary Medicine Vienna, Veterinärplatz 1, A 1210 Vienna, Austria.
| | - Angela Vobornik
- Department for Companion Animals and Horses, University of Veterinary Medicine Vienna, Veterinärplatz 1, A 1210 Vienna, Austria.
| | - Günther Schauberger
- WG Environmental Health, Division for Physiology and Biophysics, Department for Biomedical Sciences, University of Veterinary Medicine Vienna, Veterinärplatz 1, A 1210 Vienna, Austria.
| |
Collapse
|
7
|
Carretón E, Falcón-Cordón Y, Rodon J, Matos JI, Morchón R, Montoya-Alonso JA. Evaluation of serum biomarkers and proteinuria for the early detection of renal damage in dogs with heartworm (Dirofilaria immitis). Vet Parasitol 2020; 283:109144. [PMID: 32512422 DOI: 10.1016/j.vetpar.2020.109144] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 05/14/2020] [Accepted: 05/16/2020] [Indexed: 12/19/2022]
Abstract
Glomerulonephropathy associated with Dirofilaria immitis (heartworm) is relatively frequent in infected dogs. Given the importance and the scarcity of studies focused on its prevalence and diagnosis, the objective was to determine the prevalence of proteinuria and functional indicators of glomerular filtration rate in dogs with heartworm disease and discuss its utility in the detection of renal impairment. Sera and urine from 47 infected dogs were analyzed in a reference laboratory. Urea, creatinine, plasma proteins and serum symmetric dimethylarginine (SDMA) were analyzed in sera, while the UPC ratio was performed in urine. Dogs were further evaluated for the presence/absence of microfilariae, pulmonary and systemic hypertension, and the parasite burden was assessed. The results showed that 19.1 % of dogs showed proteinuria (UPC > 0.5) and 17 % showed borderline proteinuria (UPC 0.2-0.5). Creatinine and SDMA were high (>1.8 mg/dl and ≥18 μg/dl, respectively) in 4.2 % of dogs. UPC ratio was significantly increased in dogs with high parasite burden and in dogs with microfilariemia (p < 0.05). Dogs with pulmonary hypertension showed higher increases in proteinuria as well, which was probably due to the chronicity of the infection. No significant differences were found in serum and urine values regarding systemic blood pressure. Despite the limitations of this study, proteinuria/borderline proteinuria was present in 36.2 % of dogs with heartworm disease, and this may be due to glomerular disease. Therefore, the detection of proteinuria, along with other renal biomarkers in the diagnostic protocols, could help identify kidney alterations or risk of renal damage in heartworm disease.
Collapse
Affiliation(s)
- E Carretón
- Internal Medicine, Faculty of Veterinary Medicine, Research Institute of Biomedical and Health Sciences (IUIBS), University of Las Palmas De Gran Canaria, Las Palmas De Gran Canaria, Spain.
| | - Y Falcón-Cordón
- Internal Medicine, Faculty of Veterinary Medicine, Research Institute of Biomedical and Health Sciences (IUIBS), University of Las Palmas De Gran Canaria, Las Palmas De Gran Canaria, Spain
| | - J Rodon
- Idexx Laboratories, Barcelona, Spain
| | - J I Matos
- Internal Medicine, Faculty of Veterinary Medicine, Research Institute of Biomedical and Health Sciences (IUIBS), University of Las Palmas De Gran Canaria, Las Palmas De Gran Canaria, Spain
| | - R Morchón
- Group GIR of Animal and Human Dirofilariosis, Laboratory of Parasitology, Faculty of Pharmacy, University of Salamanca, Salamanca, Spain
| | - J A Montoya-Alonso
- Internal Medicine, Faculty of Veterinary Medicine, Research Institute of Biomedical and Health Sciences (IUIBS), University of Las Palmas De Gran Canaria, Las Palmas De Gran Canaria, Spain
| |
Collapse
|
8
|
Hezzell MJ, Foster JD, Oyama MA, Buch J, Farace G, Quinn JJ, Yerramilli M. Measurements of echocardiographic indices and biomarkers of kidney injury in dogs with chronic kidney disease. Vet J 2019; 255:105420. [PMID: 31982083 DOI: 10.1016/j.tvjl.2019.105420] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Revised: 12/09/2019] [Accepted: 12/10/2019] [Indexed: 12/15/2022]
Abstract
Pathophysiological cardiac and renal interactions are termed cardiovascular-renal disorder (CvRD). Cardiovascular disease/dysfunction secondary to kidney disease (CvRDK), is a leading cause of death in human chronic kidney disease (CKD) patients. The presence and clinical impact of CvRDK in dogs with CKD is unknown. We hypothesized that echocardiographic measurements, and cardiac and renal biomarkers, will be altered in dogs with CKD and associated with survival. Eleven dogs with CKD (n = 6 IRIS stage 2, n = 5 IRIS stage 3) and without primary cardiac disease, plus 12 healthy age-matched control dogs, were recruited to this prospective observational study. Dogs underwent standard echocardiography, glomerular filtration rate (GFR) estimation by iohexol clearance, and measurement of plasma cardiac troponin I and N-terminal pro-B-type natriuretic peptide (NT-proBNP), plasma and urinary cystatin B, and urinary clusterin and neutrophil gelatinase-associated lipocalin (NGAL). Values were compared between groups, and their association with all-cause mortality explored. Dogs with CKD had significantly lower GFR and higher NT-proBNP, urinary cystatin B, clusterin, and NGAL, compared to controls (P < 0.05). Echocardiographic measurements were similar between dogs with CKD and controls. Median follow-up time was 666 days, during which six dogs with CKD died. Risk of death was associated with increasing age, serum total protein, and normalized left ventricular posterior wall thickness (LVPWDN) and decreasing bodyweight and packed cell volume. Although baseline differences in echocardiographic measurements were not evident between dogs with moderate CKD and controls, the presence of CvRDK was suggested by the association between LVPWDN and survival.
Collapse
Affiliation(s)
- M J Hezzell
- Department of Clinical Studies - Philadelphia, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Bristol Veterinary School, University of Bristol, Langford House, Langford, Bristol, BS40 5DU, UK.
| | - J D Foster
- Department of Clinical Studies - Philadelphia, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Friendship Hospital for Animals, 4105 Brandywine Street NW, Washington, DC 20016, USA
| | - M A Oyama
- Department of Clinical Studies - Philadelphia, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - J Buch
- IDEXX Laboratories Inc., One IDEXX Drive, Westbrook, ME 04092, USA
| | - G Farace
- IDEXX Laboratories Inc., One IDEXX Drive, Westbrook, ME 04092, USA
| | - J J Quinn
- IDEXX Laboratories Inc., One IDEXX Drive, Westbrook, ME 04092, USA
| | - M Yerramilli
- IDEXX Laboratories Inc., One IDEXX Drive, Westbrook, ME 04092, USA
| |
Collapse
|
9
|
Snead EC, Milo JE, McCrea CA, Montgomery JE, Feng CX, Wesolowski MJ, Wanasundara SN, Wesolowski CA. Tikhonov gamma variate adaptive regularization applied to technetium Tc 99m diethylenetriamine pentaacetic acid plasma clearance, compared with three other methods, for measuring glomerular filtration rate in cats. Am J Vet Res 2019; 80:416-424. [PMID: 30919678 DOI: 10.2460/ajvr.80.4.416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate agreement of 4 methods (Tikhonov gamma variate adaptive regularization of plasma concentration-time curve fitting applied to technetium Tc 99m diethylenetriamine pentaacetic acid [99mTc-DTPA] plasma clearance [Tk-GV], plasma clearance of exogenous creatinine [CrCL], Gates gamma camera-based measurement method with 99mTc-DTPA renal clearance and dynamic scintigraphy [GTS], and iohexol renal clearance assessed with dynamic CT with Patlak plotting [CT-Pp]) for measuring glomerular filtration rates (GFR) in healthy cats. ANIMALS 7 healthy, laboratory-raised cats. PROCEDURES Each method for measuring GFR was performed twice in 7 cats at 24-day intervals. The Wilcoxon signed-rank sum test was used to compare the results obtained from the 14 studies for each method. Results from the 4 methods were assessed for agreement and correlation. RESULTS The median GFR values were 2.75, 2.83, 3.14, and 4.26 mL/min/kg, for Tk-GV, CT-Pp, plasma CrCL, and GTS, respectively. Analysis with Wilcoxon signed-rank sum tests identified significant pairwise differences between results obtained with the Tk-GV versus the plasma CrCL method, the Tk-GV versus the GTS method, and the plasma CrCL versus the GTS method. The least variable method was Tk-GV, with an SD of 1.27 (mL/min/kg). CONCLUSIONS AND CLINICAL RELEVANCE Findings indicated that Tk-GV yielded GFR measurements comparable with those obtained with CT-Pp, plasma CrCL, and GTS; however, the Tk-GV method yielded the tightest range of results among the methods evaluated.
Collapse
|
10
|
Brown CA, Rissi DR, Dickerson VM, Davis AM, Brown SA, Schmiedt CW. Chronic Renal Changes After a Single Ischemic Event in an Experimental Model of Feline Chronic Kidney Disease. Vet Pathol 2019; 56:536-543. [PMID: 30895907 DOI: 10.1177/0300985819837721] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Previous work demonstrated renal fibrosis 70 days after a single unilateral in vivo renal ischemic event, but changes associated with a single episode of renal ischemia past this time are unknown. In this study, we evaluated renal function and structural changes 6 months after a 90-minute in vivo unilateral renal ischemic event. Six adult female cats underwent unilateral renal ischemia and renal function was followed for 6 months, at which time the kidneys were evaluated by histology and histomorphometry. Over time, there was a significant reduction in the glomerular filtration rate and an elevation of serum creatinine of 31% and 42%, respectively. All cats had tubulointerstitial lesions characterized by segmental interstitial inflammation, tubular atrophy, and interstitial fibrosis. Unlike short-term studies, ischemic kidneys had variable numbers of obsolescent glomeruli, consistent with the development of atubular glomeruli and subsequent ischemic glomerulosclerosis. Chronic changes associated with acute renal ischemia may include loss of function and glomerulosclerosis.
Collapse
Affiliation(s)
- Cathy A Brown
- 1 Athens Veterinary Diagnostic Laboratory, University of Georgia College of Veterinary Medicine, Athens, GA, USA
| | - Daniel R Rissi
- 1 Athens Veterinary Diagnostic Laboratory, University of Georgia College of Veterinary Medicine, Athens, GA, USA
| | - Vanna M Dickerson
- 2 Department of Small Animal Medicine and Surgery, University of Georgia College of Veterinary Medicine, Athens, GA, USA
| | - Anastacia M Davis
- 2 Department of Small Animal Medicine and Surgery, University of Georgia College of Veterinary Medicine, Athens, GA, USA
| | - Scott A Brown
- 3 Department of Physiology and Pharmacology, University of Georgia College of Veterinary Medicine, Athens, GA, USA
| | - Chad W Schmiedt
- 2 Department of Small Animal Medicine and Surgery, University of Georgia College of Veterinary Medicine, Athens, GA, USA
| |
Collapse
|
11
|
Wallimann M, Richter H, Sieber-Ruckstuhl NS, Blaser A, Gent TC, Krämer SD, Santner G, Kircher PR, Dennler M. Influence of injection protocol and measurement technique on computed tomographic assessment of glomerular filtration rate in healthy Beagles. Am J Vet Res 2018; 79:1298-1305. [PMID: 30457905 DOI: 10.2460/ajvr.79.12.1298] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare values of CT-derived glomerular filtration rate (GFR) determined by 3 contrast-medium injection protocols and 4 measurement techniques in healthy Beagles. ANIMALS 9 healthy Beagles (mean ± SD weight, 13.2 ± 1.6 kg). PROCEDURES Each dog underwent 3 iohexol-injection protocols (700 mg of iodine/kg administered at a constant rate over 20 seconds, 700 mg of iodine/kg administered following an exponentially decelerated injection over 20 seconds, and 350 mg of iodine/kg at a constant rate over 10 seconds) during dynamic, whole renal-volume CT in randomized order with an interval of ≥ 7 days between experiments. Values of GFR determined from Patlak plots derived by use of 4 measurement techniques (standard transverse section, optimized transverse section, dorsal reconstruction, and volume calculation techniques) were compared. RESULTS The measurement technique influenced the mean ± SD GFR results (standard transverse section technique, 2.49 ± 0.54 mL/kg/min; optimized transverse section technique, 2.72 ± 0.52 mL/kg/min; dorsal reconstruction technique, 3.00 ± 0.60 mL/kg/min, and volume calculation technique, 2.48 ± 0.51 mL/kg/min). The lower iodine dose resulted in a significantly higher GFR value (3.00 ± 0.65 mL/kg/min), compared with that achieved with either higher dose administration (constant rate injection, 2.54 ± 0.45 mL/kg/min and exponentially decelerated injection, 2.47 ± 0.48 mL/kg/min). CONCLUSIONS AND CLINICAL RELEVANCE In healthy Beagles, the CT-derived GFR measurements obtained after injection of a full dose of contrast medium were reduced, compared with measurements obtained after injection of a half dose. This finding is important with regard to potential nephrotoxicosis in dogs with impaired renal function and for GFR measurement with CT-contrast medium protocols.
Collapse
|
12
|
Lippi I, Perondi F, Ceccherini G, Marchetti V, Guidi G. Effects of probiotic VSL#3 on glomerular filtration rate in dogs affected by chronic kidney disease: A pilot study. Can Vet J 2017; 58:1301-1305. [PMID: 29203940 PMCID: PMC5680728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The aim of this study was to evaluate the effects of probiotic VSL#3 on glomerular filtration rate (GFR) in dogs affected by chronic kidney disease (CKD). The treatment group (n = 30) received prescription renal diet and probiotic VSL#3 (112 to 225 × 109 lyophilized bacteria per 10 kg body weight, PO, q24h for 2 months); the control group (n = 30) received prescription renal diet and standard therapy. All dogs underwent GFR measurement at the beginning of the study (T0) and were re-evaluated by GFR measurement after 2 months (T1). The GFR was significantly higher (P = 0.0001) in the treatment group compared to the control group at T1. In the treatment group, the GFR was significantly higher (P = 0.0008) at T1 compared to T0. In the control group, the GFR was significantly lower (P = 0.001) at T1 compared to T0. VSL#3 supplementation seemed to be efficient in reducing deterioration of GFR over time in dogs affected by CKD.
Collapse
Affiliation(s)
- Ilaria Lippi
- Address all correspondence to Dr. Ilaria Lippi; e-mail:
| | | | | | | | | |
Collapse
|
13
|
Matsuda Y, Kishimoto M, Kushida K, Yamada K, Shimizu M, Itoh H. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs. Am J Vet Res 2017; 78:1049-1055. [PMID: 28836837 DOI: 10.2460/ajvr.78.9.1049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To investigate effects of changes in analytic variables and contrast medium osmolality on glomerular filtration rate estimated by CT (CT-GFR) in dogs. ANIMALS 4 healthy anesthetized Beagles. PROCEDURES GFR was estimated by inulin clearance, and dogs underwent CT-GFR with iodinated contrast medium (iohexol or iodixanol) in a crossover-design study. Dynamic renal CT scanning was performed. Patlak plot analysis was used to calculate GFR with the renal cortex or whole kidney selected as the region of interest. The renal cortex was analyzed just prior to time of the second cortical attenuation peak. The whole kidney was analyzed 60, 80, 100, and 120 seconds after the appearance of contrast medium. Automated GFR calculations were performed with preinstalled perfusion software including 2 noise reduction levels (medium and strong). The CT-GFRs were compared with GFR estimated by inulin clearance. RESULTS There was no significant difference in CT-GFR with iohexol versus iodixanol in any analyses. The CT-GFR at the renal cortex, CT-GFR for the whole kidney 60 seconds after appearance of contrast medium, and CT-GFR calculated by perfusion software with medium noise reduction did not differ significantly from GFR estimated by inulin clearance. The CT-GFR was underestimated at ≥ 80 seconds after contrast medium appearance (whole kidney) and when strong noise reduction was used with perfusion CT software. CONCLUSIONS AND CLINICAL RELEVANCE Selection of the renal cortex as region of interest or use of the 60-second time point for whole-kidney evaluation yielded the best CT-GFR results. The perfusion software used produced good results with appropriate noise reduction. IMPACT FOR HUMAN MEDICINE The finding that excessive noise reduction caused underestimation of CT-GFR suggests that this factor should also be considered in CT-GFR examination of human patients.
Collapse
|
14
|
Sasaki Y, Iwama R, Shimamura S, Katayama M, Uzuka Y, Yabe K, Takasuna K, Satoh H, Furuhama K. Estimation of glomerular filtration rate in dogs by a single-blood sample method involving iodixanol. Am J Vet Res 2016; 76:828-35. [PMID: 26309112 DOI: 10.2460/ajvr.76.9.828] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To establish a simplified single-blood-sample method (SBSM) involving iodixanol to estimate glomerular filtration rate (GFR) in dogs and compare data provided by that procedure with data provided by a conventional multiple-blood-sample method (MBSM) involving inulin. ANIMALS 26 healthy dogs and 36 dogs with naturally occurring renal disease. PROCEDURES Dogs were used in various preliminary experiments to establish protocols for the SBSM and the MBSM of GFR estimation. To evaluate the relationship between GFRs obtained by the SBSM and the MBSM each involving iodixanol, iodixanol (40 mg of I/kg) was administered IV to 26 healthy dogs and 36 dogs with renal disease; blood sample collection was performed before and at 60, 90, and 120 minutes after the injection. To evaluate the relationship between GFRs obtained by the SBSM involving iodixanol and the MBSM involving inulin, iodixanol (40 mg of I/kg) and inulin (50 mg/kg) were coadministered IV to 22 healthy dogs and 3 dogs with renal disease, followed by blood sample collection 30, 60, 90, and 120 minutes later. Serum iodixanol and inulin concentrations were separately determined by reverse-phase high-performance liquid chromatography. RESULTS Findings revealed a correlation (r = 0.99) between GFR estimated by the SBSM and MBSM each involving iodixanol. Likewise, GFR estimated by the SBSM involving iodixanol was correlated (r = 0.89) with that estimated by the MBSM involving inulin. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that the SBSM involving iodixanol can be applied to estimate GFR in dogs, instead of use of an MBSM.
Collapse
|
15
|
Steinbach S, Krolop N, Strommer S, Herrera-Pérez Z, Geraci S, Friedemann J, Gretz N, Neiger R. A pilot study to assess the feasibility of transcutaneous glomerular filtration rate measurement using fluorescence-labelled sinistrin in dogs and cats. PLoS One 2014; 9:e111734. [PMID: 25423195 PMCID: PMC4244090 DOI: 10.1371/journal.pone.0111734] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Accepted: 10/07/2014] [Indexed: 01/14/2023] Open
Abstract
In dogs and cats an assessment of renal function is often needed, however, existing methods including urine and plasma clearances are invasive, cumbersome and time consuming. This pilot study evaluated the feasibility of a transcutaneous glomerular filtration rate (GFR) measurement in dogs and cats. Additionally the optimal dose and location for the transcutaneous measurement device were investigated. Renal elimination of fluorescein-isothiocyanate-labelled sinistrin (FITC-S) was measured transcutaneously for 4 hours. The procedures were performed in awake, freely moving animals using escalating doses of FITC-S (10 mg/kg, 30 mg/kg, 50 mg/kg) with a wash-out period of at least 24 h in between. Multiple devices were placed on each animal. The resulting FITC-S disappearance curves were visually assessed to determine the most suitable location and the appropriate dose to reach an adequate transcutaneous peak signal for kinetic analysis. In both species 30 mg/kg were adequate for kinetic calculation. The most suitable place for the device was the lateral thoracic wall in dogs and the ventral abdominal wall in cats, respectively. Transcutaneous FITC-S clearance was then repeated using the optimal dose and location and in parallel with an additional plasma sinistrin clearance. Plasma elimination half-lives [min] were 26, 31 and 35, and corresponding transcutaneous elimination half-lives [min] were 26, 34 and 55, respectively in the dogs. Plasma elimination half-lives [min] were 51, 60 and 61, and corresponding transcutaneous elimination half-lives [min] were 75, 96 and 83, respectively in the cats. In conclusion, transcutaneous FITC-S clearance is a feasible method for the assessment of GFR in awake dogs and cats. It is noninvasive, well tolerated and easy to perform even in a clinical setting with results being readily available. A dose of 30 mg/kg of FITC-S seems adequate for kinetic assessment. Further studies are now needed to establish reference values and evaluate transcutaneous renal clearance in various conditions.
Collapse
Affiliation(s)
- Sarah Steinbach
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
- * E-mail:
| | - Nora Krolop
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
| | - Sellyn Strommer
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
| | | | - Stefania Geraci
- Medical Research Center, University of Heidelberg, Mannheim, Germany
| | - Jochen Friedemann
- Medical Research Center, University of Heidelberg, Mannheim, Germany
| | - Norbert Gretz
- Medical Research Center, University of Heidelberg, Mannheim, Germany
| | - Reto Neiger
- Small Animal Clinic, (Internal Medicine), Justus – Liebig – University, Giessen, Germany
| |
Collapse
|
16
|
Ghys L, Paepe D, Smets P, Lefebvre H, Delanghe J, Daminet S. Cystatin C: a new renal marker and its potential use in small animal medicine. J Vet Intern Med 2014; 28:1152-64. [PMID: 24814357 PMCID: PMC4857948 DOI: 10.1111/jvim.12366] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Revised: 02/27/2014] [Accepted: 03/18/2014] [Indexed: 01/01/2023] Open
Abstract
The occurrence of chronic kidney disease is underestimated in both human and veterinary medicine. Glomerular filtration rate (GFR) is considered the gold standard for evaluating kidney function. However, GFR assessment is time-consuming and labor-intensive and therefore not routinely used in practice. The commonly used indirect GFR markers, serum creatinine (sCr) and urea, are not sufficiently sensitive or specific to detect early renal dysfunction. Serum cystatin C (sCysC), a proteinase inhibitor, has most of the properties required for an endogenous GFR marker. In human medicine, numerous studies have evaluated its potential use as a GFR marker in several populations. In veterinary medicine, this marker is gaining interest. The measurement is easy, which makes it an interesting parameter for clinical use. This review summarizes current knowledge about cystatin C (CysC) in humans, dogs, and cats, including its history, assays, relationship with GFR, and biological and clinical variations in both human and veterinary medicine.
Collapse
Affiliation(s)
- L. Ghys
- Department of Medicine and Clinical Biology of Small AnimalsFaculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - D. Paepe
- Department of Medicine and Clinical Biology of Small AnimalsFaculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - P. Smets
- Department of Medicine and Clinical Biology of Small AnimalsFaculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - H. Lefebvre
- Clinical Research UnitNational Veterinary School of ToulouseToulouse Cedex 3France
| | - J. Delanghe
- Department of Clinical Chemistry, Microbiology and ImmunologyFaculty of Health Medicine and Life SciencesGhent UniversityGhentBelgium
| | - S. Daminet
- Department of Medicine and Clinical Biology of Small AnimalsFaculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| |
Collapse
|
17
|
Kirberger RM, Cassel N, Carstens A, Goddard A. The effects of repeated intravenous iohexol administration on renal function in healthy beagles--a preliminary report. Acta Vet Scand 2012; 54:47. [PMID: 22892108 PMCID: PMC3533856 DOI: 10.1186/1751-0147-54-47] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2012] [Accepted: 08/02/2012] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND Contrast induced nephrotoxicity (CIN) is a well described syndrome in humans undergoing contrast medium examinations. To date CIN has received minimal attention in the veterinary literature despite increasing use of contrast medium examinations in computed tomographic studies. METHODS This prospective study evaluated the effect of 1290 mg/kg iohexol given intravenously to 5 normal beagle dogs in a divided dose at an interval of 6-8 weeks. Renal function was evaluated by means of scintigraphically determined glomerular filtration rate (GFR) and a variety of laboratory assays. RESULTS Only GFR showed a significant decrease (17%) after the second injection but not to a clinically or pathologically significant level. CONCLUSIONS No clinically significant effect of repeated contrast medium administration was determined in this limited study. However in dogs with reduced renal function the risk of CIN is likely to increase dramatically post contrast administration.
Collapse
Affiliation(s)
- Robert M Kirberger
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, Republic of South Africa
| | - Nicolette Cassel
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, Republic of South Africa
| | - Ann Carstens
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, Republic of South Africa
| | - Amelia Goddard
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, Republic of South Africa
| |
Collapse
|
18
|
Michigoshi Y, Yamagishi N, Satoh H, Kato M, Furuhama K. Using a single blood sample and inulin to estimate glomerular filtration rate in rabbits. J Am Assoc Lab Anim Sci 2011; 50:702-707. [PMID: 22330718 PMCID: PMC3189675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Revised: 03/31/2011] [Accepted: 04/20/2011] [Indexed: 05/31/2023]
Abstract
To establish a simple procedure for estimating the glomerular filtration rate (GFR) in conscious rabbits, we used the conventional multisample approach to develop a single-blood-sample method. A bolus injection of inulin was administered intravenously at a dose of 40 mg/kg to male New Zealand White rabbits, and blood was collected 30, 60, 90, and 120 min later. Serum inulin, urea nitrogen, and creatinine concentrations were determined. Using this multi-sample method, the reference GFR in clinically healthy rabbits was 4.01 ± 0.17 mL/min/kg (n = 17). In rabbits given an intravenous injection of the antitumor agent cisplatin, GFR fell before serum urea nitrogen and creatinine concentrations increased. Based on cumulative GFR data from healthy and nephropathy rabbits, the GFR obtained from the 3-sample method (30-, 60-, and 90-min samples) was closely correlated (r = 0.99) with that calculated from the estimated distribution volume and serum inulin concentration at 90 min after inulin injection in the single-blood-sample method. These results demonstrate that the single-blood-sample method supports sequential GFR measurements in rabbits and is a versatile procedure not only for research purposes but also in clinical settings.
Collapse
Affiliation(s)
| | - Norio Yamagishi
- Veterinary Clinical Medicine, Iwate University, Morioka, Japan
- United Graduate School of Veterinary Science, Gifu University, Gifu, Japan; and
| | | | - Masaki Kato
- Departments of Veterinary Basic Medicine and
| | - Kazuhisa Furuhama
- Departments of Veterinary Basic Medicine and
- United Graduate School of Veterinary Science, Gifu University, Gifu, Japan; and
| |
Collapse
|
19
|
Von Hendy-Willson VE, Pressler BM. An overview of glomerular filtration rate testing in dogs and cats. Vet J 2011; 188:156-65. [PMID: 20541957 PMCID: PMC2980797 DOI: 10.1016/j.tvjl.2010.05.006] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2009] [Revised: 04/21/2010] [Accepted: 05/07/2010] [Indexed: 12/25/2022]
Abstract
Determination of glomerular filtration rate (GFR) is a valuable, yet underused, diagnostic tool for evaluating renal function in dogs and cats. This article first reviews the hormonal and hemodynamic factors which contribute to GFR, followed by a description of considerations when selecting a pharmacokinetic model and methods of animal-to-animal standardization. The best-characterized existing GFR markers, including creatinine, radiolabeled markers, and iohexol, are reviewed in depth, as well as alternative but lesser used techniques. A weighted means analysis of reported GFR measurements in healthy dogs and cats and a review of selected studies that have examined GFR alterations in animals with naturally occurring and experimental diseases provide the reader with preliminary guidelines on expected GFR results in these species and disease conditions.
Collapse
Affiliation(s)
| | - Barrak M. Pressler
- Department of Veterinary Clinical Sciences, Purdue University, West Lafayette, IN 47907 USA
| |
Collapse
|
20
|
Hecht S, Lawson SM, Lane IF, Sharp DE, Daniel GB. (99m)Tc-DTPA diuretic renal scintigraphy in dogs with nephroureterolithiasis. Can Vet J 2010; 51:1360-1366. [PMID: 21358928 PMCID: PMC2978988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This study evaluated the results of diuretic renal scintigraphy in dogs with urolithiasis. Eighty-three kidneys with nephroureterolithiasis +/- renal pelvis/ureteral dilation were included in the study. Sixty-three kidneys showed a non-obstructive pattern, with a steep drop or gradual downward slope of renal time-activity curve (TAC). Excretion half-time of radiopharmaceutical (T(1/2)) was 3.99 (2.99 to 7.95) min. Three kidneys showed an obstructive pattern, with continuous rise of the TAC and median T(1/2) of -10.71 (-5.20 to -17.56) min. Fifteen kidneys had non-diagnostic studies characterized by flat TAC. Individual kidney glomerular filtration rate was <0.5 mL/min/kg body weight in most non-diagnostic studies. Diuretic renal scintigraphy appears to be a useful adjunct modality to rule out or confirm ureteral obstruction in dogs. Additional diagnostic procedures may be necessary to achieve a definitive diagnosis in cases of severely impaired renal function.
Collapse
Affiliation(s)
- Silke Hecht
- Department of Small Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, Tennessee, USA.
| | | | | | | | | |
Collapse
|
21
|
Linnetz EH, Graves TK. Glomerular filtration rate in general small animal practice. Compend Contin Educ Vet 2010; 32:E1-E6. [PMID: 21308659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Quantitative evaluation of renal function in small animal general practice has remained essentially unchanged for decades. Glomerular filtration rate (GFR) is considered the gold standard for evaluating functional renal mass in veterinary medicine. For practical and financial reasons, GFR testing was previously available only at referral veterinary hospitals. Newer techniques for estimating GFR now allow the routine performance of this test in any small animal practice.
Collapse
Affiliation(s)
- Eric H Linnetz
- Chippens Hill Veterinary Hospital, Bristol, Connecticut, USA
| | | |
Collapse
|
22
|
Michałek K, Ozgo M, Skrzypczak WF. Renal regulation of calcium-phosphate metabolism in single- and twin pregnant goats. Folia Biol (Praha) 2009; 57:199-205. [PMID: 19777965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The aim of this study was the clearance assessment of renal function in single- and twin-pregnant goats and a comparison of selected parameters associated with calcium-phosphate management in terms of litter size. Clearance studies were carried out on 16 pregnant Polish White Improved goats (8 single pregnancies and 8 twin pregnancies). It was demonstrated that the kidneys of pregnant goats regulate the calcium-phosphate balance to a great extent. In spite of observed differences in parameters of renal functions, plasma calcium and inorganic phosphorus concentrations were comparable with normal reference values in further weeks of pregnancy. Significant differences in renal function between single and twin pregnancies were not observed. Gut absorption and/or bone tissue metabolism seem important for the maintenance of appropriate calcium-phosphate status.
Collapse
Affiliation(s)
- Katarzyna Michałek
- Department of Animal Physiology and Cytobiology, West Pomeranian University of Technology, Dr Judyma 6, 71-466 Szczecin, Poland.
| | | | | |
Collapse
|
23
|
KuKanich B, Coetzee JF, Gehring R, Hubin M. Comparative disposition of pharmacologic markers for cytochrome P-450 mediated metabolism, glomerular filtration rate, and extracellular and total body fluid volume of Greyhound and Beagle dogs. J Vet Pharmacol Ther 2007; 30:314-9. [PMID: 17610404 DOI: 10.1111/j.1365-2885.2007.00875.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The purpose of the study was to compare the disposition of pharmacologic markers for cytochrome P-450 (CYP) metabolism, glomerular filtration rate (GFR), and extracellular (ECFV) and total body fluid volumes (TBFV) of Greyhounds and Beagles. Six healthy Greyhound and six healthy Beagle dogs were studied. Antipyrine, a marker for CYP metabolism and TBFV, and inulin, a marker for the GFR and ECFV, were administered i.v. Samples were collected at predetermined times and plasma was analyzed by validated high-pressure liquid chromatography (HPLC) methods. There were no differences in the disposition or pharmacokinetic parameters for inulin between the dog breeds. However, the clearance of antipyrine (mean = 8.33 mL/min/kg) in Greyhounds was significantly slower than Beagles (13.42 mL/min/kg, P = 0.004). The volume of distribution of antipyrine was significantly larger in Greyhounds (0.789 L/kg) than in Beagles (0.644 L/kg, P = 0.01). The half-life of antipyrine was significantly longer in Greyhounds (1.09 h) compared with Beagles (0.55 h, P = 0.002). The in vitro plasma protein binding of antipyrine was significantly less in Greyhounds (28%) compared with Beagles (40.3%, P = 0.008). Greyhounds exhibited significantly slower CYP metabolism, higher TBFV, and lower in vitro protein binding of antipyrine compared with Beagles. No differences in GFR or ECFV were found.
Collapse
Affiliation(s)
- B KuKanich
- Department of Anatomy, PharmCATS, College of Veterinary Medicine, Kansas State University, Manhattan, KS 66506, USA.
| | | | | | | |
Collapse
|
24
|
Fusellier M, Desfontis JC, Madec S, Gautier F, Debailleul M, Gogny M. Influence of three anesthetic protocols on glomerular filtration rate in dogs. Am J Vet Res 2007; 68:807-11. [PMID: 17669018 DOI: 10.2460/ajvr.68.8.807] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To investigate renal function in clinically normal dogs when awake and during anesthesia with medetomidine; xylazine, ketamine, and halothane (XKH) combination; or propofol. ANIMALS 10 adult female Beagles. PROCEDURES At intervals of 15 days, dogs were administered medetomidine (0.05 mg/kg, IV); XKH combination (xylazine [1 mg/kg, IV], ketamine [5 mg/kg, IV], and halothane [1% end-tidal concentration]); or propofol (6 mg/kg, IV) to induce anesthesia or no treatment. Glomerular filtration rate was assessed on the basis of renal uptake (RU; determined via renal scintigraphy) and plasma clearance (CL) of technetium 99m-labeled diethylenetriamine pentaacetic acid ((99m)Tc-DTPA). RESULTS In awake dogs, mean +/- SEM RU was 9.7 +/- 0.4% and CL was 3.86 +/- 0.23 mL/min/ kg. Renal uptake and CL of (99m)Tc-DTPA were not significantly modified by administration of XKH (RU, 11.4 +/- 0.9%; CL, 4.6 +/- 0.32 mL/min/kg) or propofol (RU, 9.7 +/- 0.3%; CL, 3.78 +/- 0.37 mL/min/kg). Half-life elimination time of plasma (99m)Tc-DTPA decreased significantly in XKH-anesthetized dogs, compared with the value in awake dogs (14.4 minutes and 28.9 minutes, respectively). However, glomerular filtration rate was significantly decreased by administration of medetomidine (RU, 3.9 +/- 0.1%), and the time to maximum kidney activity was significantly increased (867 +/- 56 seconds vs 181 +/- 11 seconds without anesthesia). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that anesthesia with propofol or an XKH combination did not alter renal function in healthy Beagles, but anesthesia with medetomidine decreased early RU of (99m)Tc-DTPA.
Collapse
Affiliation(s)
- Marion Fusellier
- Animal Pathophysiology and Functional Pharmacology Unit (UPSP 5304), National Veterinary School, BP 40706, F-44307 Nantes, France
| | | | | | | | | | | |
Collapse
|
25
|
Urie BK, Tillson DM, Smith CM, Brawner WR, Almond GT, Beard DM, Lenz SD, Lothrop CD. Evaluation of clinical status, renal function, and hematopoietic variables after unilateral nephrectomy in canine kidney donors. J Am Vet Med Assoc 2007; 230:1653-6. [PMID: 17542732 DOI: 10.2460/javma.230.11.1653] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To determine clinical status and renal and hematopoietic function after kidney donation and identify risks associated with kidney donation in dogs. DESIGN Prospective study. ANIMALS 14 dogs that underwent unilateral nephrectomy for kidney donation. PROCEDURES Records were reviewed retrospectively to collect data regarding prenephrectomy clinicopathologic variables. Dogs were reexamined prospectively at various times after nephrectomy, and pre- and postnephrectomy CBC, serum biochemical analyses, urinalysis, and urine protein-to-urine creatinine ratio were compared. Six dogs had postnephrectomy renal volume determined ultrasonographically, and 4 of those dogs also underwent scintigraphic determination of glomerular filtration rate and renal biopsy. RESULTS All dogs were clinically normal at the time of reevaluation. There were no significant differences between prenephrectomy and postnephrectomy values for BUN concentration or urine specific gravity. Mean postnephrectomy serum creatinine concentration was significantly greater than prenephrectomy concentration. Mean serum phosphorus concentration was significantly decreased after nephrectomy, and mean Hct, corpuscular volume, and corpuscular hemoglobin concentration were significantly increased after nephrectomy. Postnephrectomy renal volume was greatest in dogs < 12 months old at the time of surgery. Mean postnephrectomy glomerular filtration rate was 2.82 +/- 1.12 mL/kg/ min (1.28 +/- 0.51 mL/lb/min). Renal biopsy specimens obtained during and after nephrectomy were histologically normal. CONCLUSIONS AND CLINICAL RELEVANCE Renal and hematopoietic variables were within reference ranges in dogs examined up to 2.5 years after unilateral nephrectomy. Compensatory renal hypertrophy was greatest in dogs < 1 year of age at donation. Donor age, along with histocompatability, may be an important factor in selecting dogs for kidney donation.
Collapse
Affiliation(s)
- Bridget K Urie
- Department of Clinical Sciences, College of Veterinary Medicine, Auburn University, Auburn, AL 36849, USA
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Alexander K, Del Castillo JRE, Ybarra N, Morin V, Gauvin D, Authier S, Vinay P, Troncy E. Single-slice dynamic computed tomographic determination of glomerular filtration rate by use of Patlak plot analysis in anesthetized pigs. Am J Vet Res 2007; 68:297-304. [PMID: 17331020 DOI: 10.2460/ajvr.68.3.297] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare glomerular filtration rate (GFR) as estimated from Patlak plot analysis by use of single-slice computed tomography (CT) with that obtained from clearance of plasma inulin in pigs. ANIMALS 8 healthy anesthetized juvenile pigs. PROCEDURES All pigs underwent precontrast, whole-kidney, helical CT; postcontrast single-slice dynamic CT; and postcontrast, whole-kidney CT for volume determination. On dynamic images, corrected Hounsfield unit values were determined for each kidney and the aorta. A Patlak plot for each kidney was generated, and plasma clearance per unit volume was multiplied by renal volume to obtain whole-animal contrast clearance. Mean GFR determined via inulin clearance (Inu-GFR) was measured from each kidney and correlated to mean GFR determined via CT (CT-GFR) for the left kidney, right kidney, and both kidneys by use of linear regression and Bland-Altman analyses. RESULTS CT-GFR results from 7 pigs were valid. Total and right kidney Inu-GFR were correlated with total and right kidney CT-GFR (total, R(2) = 0.85; right kidney, R(2) = 0.86). However, left kidney CT-GFR was poorly correlated with left kidney Inu-GFR (R(2) = 0.47). Bland-Altman analysis revealed no significant bias between Inu-GFR and CT-GFR for the left kidney, right kidney, or both kidneys. CONCLUSIONS AND CLINICAL RELEVANCE CT-GFR as determined by use of a single-slice acquisition technique, low-dose of iohexol, and Patlak plot analysis correlated without bias with Inu-GFR for the right kidney and both kidneys (combined). This technique has promise as an accurate CT-GFR method that can be combined with renal morphologic evaluation.
Collapse
Affiliation(s)
- Kate Alexander
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, QC J2S 7C6, Canada
| | | | | | | | | | | | | | | |
Collapse
|
27
|
King MD, Waldron DR, Barber DL, Larson MM, Saunders GK, Troy GC, Zimmerman-Pope N, Ward DL. Effect of nephrotomy on renal function and morphology in normal cats. Vet Surg 2007; 35:749-58. [PMID: 17187637 DOI: 10.1111/j.1532-950x.2006.00219.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To assess effects over 12 weeks of bisection nephrotomy on renal function, size, and morphology in cats. STUDY DESIGN Controlled, randomized, blinded experiment. SAMPLE POPULATION Ten adult female cats. METHODS Glomerular filtration rate (GFR), determined by quantitative renal scintigraphy using (99m)Technetium-diethylenetriamine-pentaacetic acid, urinalysis, urine culture, and ultrasonographic measurement of renal size were performed preoperatively. Left or right nephrotomy (5 cats/group) was performed. Total and individual kidney GFRs were determined at 2, 28, and 84 days, ultrasonographic measurements at 28 and 86 days, and ultrasound-guided biopsy at 86 days. RESULTS No significant differences in mean GFR and kidney size of operated versus unoperated kidneys were observed. Individual GFR and renal size of all except 1 cat remained within normal limits. Two cats had evidence of transient ureteral obstruction in the immediate postoperative period. No significant, generalized histologic abnormalities were observed. CONCLUSIONS Bisection nephrotomy in normal cats does not adversely affect renal function or morphology during the initial 12 weeks. CLINICAL RELEVANCE Bisection nephrotomy can be safely performed in normal feline kidneys without causing a significant deleterious effect on renal function. Studies in cats with pre-existing renal insufficiency are needed to ensure adverse effects would not occur in clinical cases where this surgical procedure is warranted.
Collapse
Affiliation(s)
- Michael D King
- Virginia-Maryland Regional College of Veterinary Medicine, Virginia Tech, Blacksburg, VA, USA.
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
Pimobendan has a dual mechanism of action: it increases myocardial contractility by increasing calcium sensitization to troponin C and it promotes vasodilation by inhibiting PDEIII. This study examined the effects of pimobendan on cardiac function, hemodynamics, and neurohormonal factors in dogs with mild mitral regurgitation (MR). The dogs were given 0.25 mg/kg of pimobendan orally every 12 hr for 4 weeks. With pimobendan, the heart rate and stroke volume did not change, but the systolic blood pressure gradually decreased and the degree of mitral valve regurgitation tended to decrease. Renal blood flow was significantly increased and the glomerular filtration rate was slightly increased at 2 and 4 weeks. Furthermore, over the 4-week period, the plasma norepinephrine concentration decreased significantly, the systolic index increased slightly, the left atrial diameter and the left ventricular diameters decreased significantly, and the heart size improved. Given these results, pimobendan appears to be useful for treating MR in dogs. However, further long-term studies of pimobendan involving a larger number of dogs with mild and moderate MR are needed to establish the safety of pimobendan and document improvements in quality of life.
Collapse
Affiliation(s)
- Nobuyuki Kanno
- Laboratory of Veterinary Internal Medicine, Department of Veterinary Medicine, College of Bioresource Sciences, Nihon University, Fujisawa, Japan
| | | | | | | | | | | |
Collapse
|
29
|
Patel M, Rogers JT, Pane EF, Wood CM. Renal responses to acute lead waterborne exposure in the freshwater rainbow trout (Oncorhynchus mykiss). Aquat Toxicol 2006; 80:362-71. [PMID: 17125852 DOI: 10.1016/j.aquatox.2006.09.012] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2006] [Revised: 09/12/2006] [Accepted: 09/16/2006] [Indexed: 05/12/2023]
Abstract
The possible nephrotoxic effects of waterborne lead exposure (as Pb(NO3)2) were investigated in the freshwater rainbow trout (Oncorhynchus mykiss). Kidney lead accumulation was time-dependent, increasing upon exposure to 0.57+/-0.01 mg dissolved Pb L(-1) for up to 96 h with a significantly higher burden occurring in the posterior kidney compared to the anterior segment. Urine analyses in trout exposed to 1.20+/-0.09 mg dissolved Pb L(-1) revealed a significant increase in urinary lead excretion rate throughout 96 h of exposure. Urine flow rate and glomerular filtration rate (GFR) were not impacted with the exception of a significant decrease in GFR from 84 to 96 h in lead-exposed trout. Urine pH decreased significantly over time in lead-exposed fish. Correspondingly, urine ammonia excretion rate showed a marked increase from 48 h onwards. In experimental fish, urine glucose excretion was significantly greater by 96 h while urine lactate, urea and protein excretion were not significantly altered by lead exposure. The urine excretion rate of Ca2+ increased significantly by approximately 43% after only 24 h of lead exposure, and was maintained at a higher rate than controls for up to 96 h. Magnesium excretion increased in a time-dependent fashion, reaching a two- to three-fold rise by 96 h. In contrast, rates of Na+ and Cl- excretion were decreased in experimental fish by approximately 30% by 48 h, this trend continuing for the duration of lead-exposure. There were no changes in any of these parameters in similarly treated control fish. Clearance ratio analyses indicated progressive decreases in the net reabsorption efficiencies of the renal system for Ca2+, Mg2+, Pb, and glucose, suggesting that the active tubular transport mechanisms for these substances were inhibited by lead exposure, while Na+, K+, Cl-, lactate, and protein reabsorptions were unaffected. Net ammonia secretion increased. We conclude that changes in renal function both reflect and help to minimize some of the associated disturbances in systemic physiology. Lead-induced ionoregulatory toxicity in rainbow trout, particularly the disturbance of Ca2+ homeostasis, is not exclusively a branchial phenomenon, but is in part a result of disruption of ionoregulatory mechanisms at the kidney. This action of lead outside the gills is critical to consider when developing guidelines for water quality.
Collapse
Affiliation(s)
- Monika Patel
- Department of Biology, McMaster University, 1280 Main Street West, Hamilton, Ontario, Canada L8S 4K1.
| | | | | | | |
Collapse
|
30
|
Le Garreres A, Laroute V, De La Farge F, Boudet KG, Lefebvre HP. Disposition of plasma creatinine in non-azotaemic and moderately azotaemic cats. J Feline Med Surg 2006; 9:89-96. [PMID: 17049290 DOI: 10.1016/j.jfms.2006.08.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2006] [Indexed: 11/16/2022]
Abstract
The objectives of this study were to compare assay methods for plasma creatinine (Pl-creat) in cats and to describe the disposition of creatinine and iohexol in 12 healthy and moderately azotaemic cats. Exogenous creatinine and iohexol were injected simultaneously by intravenous bolus, and repeated blood samples were taken to determine the pharmacokinetic parameters of each marker. Pl-creat was assayed by high-performance liquid chromatography (HPLC), Jaffé and enzymatic methods. The enzymatic method was shown to be more reliable than the Jaffé method. Two stereoisomers, exo- and endo-iohexol were identified. The plasma clearance of creatinine (2.3+/-0.66 ml/min/kg) was significantly higher (P<0.001) than that of exo-iohexol (1.7+/-0.40 ml/min/kg). The volume of distribution (447+/-97 ml/kg) and elimination half-life (181+/-77 min) of creatinine were also higher (P<0.001) than those of exo- and endo-iohexol. The estimated daily endogenous production of creatinine was 65+/-23 mg/kg. None of the pharmacokinetic parameters was changed by the azotaemic status of the animals.
Collapse
|
31
|
Abstract
Greyhounds have significantly higher serum creatinine (SCr) concentration than do non-Greyhound dogs that may be attributable to differences in glomerular filtration rate (GFR). By means of plasma clearance of technetium Tc 99m diethylenetriaminepentaacetic acid, GFR was measured in 10 Greyhounds and 10 non-Greyhound dogs with normal findings of physical examination, CBC, serum biochemical analysis, and urinalysis. Dogs were fed the same diet for a minimum of 6 weeks before GFR data collection. Greyhounds had significantly higher mean +/- SD GFR (3.0 +/- 0.1 vs 2.5 +/- 0.2 ml/min/ kg; P = .01) and SCr concentration (1.8 +/- 0.1 vs 1.5 +/- 0.1 mg/dL; P = .03) than did non-Greyhound dogs, but the serum urea nitrogen (SUN) concentration was not significantly different (18 +/- 1 vs 18 +/- 2 mg/dL; P = .8). Therefore, the higher SCr concentration in Greyhounds is not attributable to decreased GFR, and may be associated with the high muscle mass in the breed. Healthy Greyhounds have higher GFR than do non-Greyhound dogs.
Collapse
Affiliation(s)
- Wm Tod Drost
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus 43210, USA.
| | | | | | | | | |
Collapse
|
32
|
Abstract
Iohexol plasma clearance as a measure of glomerular filtration was determined in 31 dogs and 19 cats after an intravenous (i.v.) bolus injection. All animals were healthy and privately owned. Serial blood samples were taken before and up to 4 h after tracer injection. Iohexol plasma concentration was determined using X-ray fluorescence. A plasma tracer elimination curve was generated and clearance was calculated by dividing the injected dose by the area under the curve estimated using a two-compartment pharmacological model. Clearance was normalized to body weight (BW), body surface area (BSA), and extracellular fluid volume (ECFV). Mean, SD, and coefficient of variation of plasma clearance, before and after normalization, were calculated. Linear regression analyses were performed between body size and normalized plasma clearances. No significant linear relation was found between BSA and clearance normalized to BSA in dogs, and between BSA, BW, ECFV and clearance normalized to BSA, BW, and ECFV in cats. The optimal method for normalization of iohexol plasma clearance in dogs was by using BSA. In cats, all three methods tested were considered satisfactory. Normalization to BSA appears to be superior to normalization to BW and ECFV in dogs, and can be recommended for clinical use.
Collapse
Affiliation(s)
- Isabelle Goy-Thollot
- Départment Animaux de Compagnie , Ecole Nationale Vétérinaire de Lyon, 1 Avenue Bourgelat-B.P. 83, 69280 Marcy l'Etoile, France
| | | | | | | | | |
Collapse
|
33
|
McClellan JM, Goldstein RE, Erb HN, Dykes NL, Cowgill LD. Effects of administration of fluids and diuretics on glomerular filtration rate, renal blood flow, and urine output in healthy awake cats. Am J Vet Res 2006; 67:715-22. [PMID: 16579767 DOI: 10.2460/ajvr.67.4.715] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVES To determine effects of commonly used diuretic treatments on glomerular filtration rate (GFR), renal blood flow (RBF), and urine output (UO) and compare 2 methods of GFR measurement in healthy awake cats. ANIMALS 8 healthy cats. PROCEDURE In a randomized crossover design, cats were randomly allocated to 4 groups: control; IV administration of fluids; IV administration of fluids and mannitol; and IV administration of fluids, dopamine, and furosemide. Inulin and para-aminohippuric acid were used for determination of plasma clearance for GFR and RBF, respectively. Plasma clearance of technetium-Tc-99m-diethylenetriaminepentacetic acid (99mTc-DTPA) was also used for GFR determination. RESULTS Furosemide-dopamine induced the largest UO, compared with other groups. Both mannitol and fluid therapy increased RBF, compared with the control group. Mannitol, and not fluid therapy, increased RBF, compared with furosemide-dopamine. There were significant differences in GFR values calculated from 99mTc-DTPA and inulin clearances between the 2 groups. In all groups, use of 99mTc-DTPA caused underestimation of GFR, compared with use of inulin. CONCLUSIONS AND CLINICAL RELEVANCE In healthy awake cats, administration of furosemide-dopamine did not increase GFR or RBF despite increased UO. Fluid therapy and fluid therapy plus mannitol improved RBF. Determination of GFR by use of 99mTc-DTPA cannot always be substituted for inulin clearance when accurate measurement is required.
Collapse
Affiliation(s)
- Jennifer M McClellan
- Department of Clinical Sciences, New York State College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | | | | | | | | |
Collapse
|
34
|
O'Dell-Anderson KJ, Twardock R, Grimm JB, Grimm KA, Constable PD. DETERMINATION OF GLOMERULAR FILTRATION RATE IN DOGS USING CONTRAST-ENHANCED COMPUTED TOMOGRAPHY. Vet Radiol Ultrasound 2006; 47:127-35. [PMID: 16553143 DOI: 10.1111/j.1740-8261.2006.00118.x] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The purpose of this project was to establish a procedure and reference values for glomerular filtration rate (GFR) using contrast-enhanced computed tomography (CT) in eight healthy dogs. A single section of the kidney was scanned sequentially after bolus injection (3 ml/s) of iohexol (300 mg/kg). Time-attenuation curves were constructed and the GFR per volume of kidney was calculated using Patlak graphical analysis software. The GFR was then converted from contrast clearance per unit volume (ml/min/ml) to contrast clearance per body weight (ml/min/kg). Individual kidney and global GFR were calculated using both CT and nuclear scintigraphy. Global GFR for each dog was also determined by plasma iohexol clearance. Contrast-enhanced CT underestimated the global GFR compared with the other two methods. The average global GFR was 2.57 +/- 0.33 ml/ min/kg using functional CT and 4.06 +/- 0.37 ml/min/kg using plasma iohexol clearance. There was significant (P < 0.05) interobserver variability of CT GFR of the right kidney and total GFR. There was decreased interobserver variability for the left kidney. There was no difference in the intraobserver variability for CT-determined individual kidney and global GFR. There was no difference between the motion corrected and nonmotion corrected values for individual and global CT GFR. Nuclear scintigraphy produced a slightly higher coefficient of variation than contrast-enhanced CT, 2.9% and 1.0%, respectively. It is hypothesized that altered renal blood flow, hematocrit of the small vessels, and nephrotoxicity play a role in the underestimation of GFR by contrast-enhanced CT.
Collapse
Affiliation(s)
- Kristen J O'Dell-Anderson
- Department of Veterinary Clinical Medicine, University of Illinois at Urbana-Champaign Urbana, IL, USA.
| | | | | | | | | |
Collapse
|
35
|
Abstract
Observer variation in kidney depth measurement for correction of soft-tissue attenuation and kidney region of interest (ROI) drawing was evaluated using 60 clinical dogs with a wide range of glomerular filtration rate (GFR) for their effect on the calculated percentage uptake of 99mTc-diethylenetriamine pentaacetic acid (DTPA) and individual kidney GFR by scintigraphy. Kidney depth was measured separately on the lateral image using two color tables: a threshold and a continuous red-green-blue. Within-observer variability of the semi-automatic ROI drawing of the estimated total GFR was up to 10% for the right kidney (RK) and 9% for the left kidney (LK). The variability was lower between observers, 6% for RK and 8% for LK. Manual ROI drawing caused more within observer variation than semi-automatic: up to 14% for RK and 11% for LK. Continuous red-green-blue table caused more variation within and between observers than threshold table. Average within-observer variability from both observers of kidney depth measurement on different color tables could vary up to 5.5% and 6.5% variation of the GFR of RK and LK, respectively. Most variation affecting the DTPA percentage uptake came from the ROI drawing technique. Variations of the method because of the effects of both kidney depth and kidney ROI drawing were up to 8% and 10% for RK and LK, respectively. To minimize these variations a threshold scale should be used for the kidney depth measurement and an automatic or semi-automatic ROI should be used whenever possible. In sequential examinations the same person should make all the measurements.
Collapse
Affiliation(s)
- Naruepon Kampa
- Department of Biomedical Sciences and Public Health, Division of Diagnostic Imaging and Clinical Chemistry, University of Agricultural Sciences, Uppsala, Sweden
| | | | | |
Collapse
|
36
|
Hartmann H, Baumgardt T, Höchel J. [Suitability of the peroral administration of the marker creatinine for the quantitative determination of the glomerular filtration rate (GFR) in dogs]. Berl Munch Tierarztl Wochenschr 2006; 119:62-7. [PMID: 16450711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Established renal function tests for the quantitative determination of the glomerular filtration rate (GFR) in small animals by means of an exogenous clearance marker like creatinine are based on the intravenous or subcutaneous administration of the marker. In order to simplify performing the test, the suitability of the peroral administration of the marker substance was tested. Exogenous creatinine was administered to 17 Beagle dogs successively by the peroral (dose: 4 g/m2 BSA) and the subcutaneous route (dose: 2 g/m2 BSA). Both routes were tested sequentially in fasted and fed animals. In addition to the peroral administration of creatinine, the absorption marker D-Xylose (dose: 0.5 g/kg body weight) was given per os. Pharmacokinetic parameters were calculated based on serum concentration--time data of both markers. Maximum serum concentrations of the exogenous creatinine (C(max) = 1284 +/- 173 micromol/l) were observed 92 +/- 19 min post-dose (t(max)) in fasted dogs after peroral administration of creatinine. C(max) (956 +/- 209 micromol/l) and t(max) (67 +/- 13 min) were statistically significantly reduced in fed animals. The exogenous plasma clearance of creatinine was about 1/3 lower in fasted animals (94 +/- 15 ml/min/m2) than in fed ones (134 +/- 28 ml/min/m2). The apparent terminal disposition half-life of the exogenous creatinine showed mean values of about 170 min (fasted) and 200 min (fed). After peroral administration of D-Xylose, fasted animals showed higher C(max) (3.9 +/- 0.99 mmol/l) and t(max) values (60 +/- 18 min) than fed dogs (C(max) = 2.2 +/- 0.55 mmol/l, t(max) = 40 +/- 15 min). C(max) and t(max) did not differ between fed and fasted dogs after subcutaneous administration of creatinine. Creatinine clearance was again higher in fed (124 +/- 12.8 ml/min/m2) than in fasted dogs (104 +/- 9.0 ml/min/m2) after subcutaneous administration of the marker. The terminal disposition half-live was, however, similar with about 130-140 min. The route of administration (peroral vs. subcutaneous) did not influence the calculated clearance (no statistical significance when p < 0.01 is required). Creatinine in a dose of 4 g/m2 BSA can be administered by the peroral route of administration for assessing the GFR. For the quantitative determination of GFR standardized condition are required, i.e. animals have to be fasted for > or = 6 hours.
Collapse
Affiliation(s)
- Helmut Hartmann
- Institut für Veterinär-Physiologie, Fachbereich Veterinärmedizin, Freie Universität Berlin.
| | | | | |
Collapse
|
37
|
Abstract
OBJECTIVE To evaluate the effects of meloxicam on renal function in dogs anaesthetized and rendered hypotensive with acepromazine-thiopental-isoflurane. ANIMALS Eight healthy beagles, four males and four females, 25.6 +/- 19.3 months old and weighing 12.8 +/- 2.0 kg. MATERIALS AND METHODS Either meloxicam suspension at a dose of 0.133 mL kg(-1) (0.2 mg kg(-1)) or 0.133 mL kg(-1) saline solution (control), were given by mouth (PO) in a randomized, cross-over fashion. The treatment or control was given 3 hours before anaesthesia. Dogs were sedated with intramuscular acepromazine 0.1 mg kg(-1). Anaesthesia was induced with intravenous thiopental, followed by tracheal intubation and maintenance with isoflurane in oxygen and air, delivered using a semi-closed breathing system. Renal function was quantified using serum biochemistry, urinalysis and glomerular filtration rate measured by scintigraphy. Analysis of variance or Friedman anova were used for statistical analysis. RESULTS Values (mean +/- SD) for mean arterial blood pressure did not differ significantly between treatments but was low (54 +/- 7 mmHg) during anaesthesia. Glomerular filtration rate did not differ significantly between treatments or over time, and results of urine and serum analysis were within reference ranges after meloxicam treatment. CONCLUSIONS AND CLINICAL RELEVANCE Meloxicam caused no adverse effects on renal function when given to healthy dogs anaesthetized and rendered hypotensive with acepromazine, thiopental and isoflurane.
Collapse
Affiliation(s)
- Ingrid M Boström
- Department of Large Animal Clinical Sciences, Faculty of Veterinary Medicine, Swedish University of Agricultural Sciences, Uppsala, Sweden.
| | | | | | | |
Collapse
|
38
|
Meintjes RA, Botha CJ, Prozesky L. Toxicity, pathophysiology and pathology in sheep following dosing of the nephrotoxic plant Nolletia gariepina (DC) Mattf. ACTA ACUST UNITED AC 2005; 72:39-53. [PMID: 15991704 DOI: 10.4102/ojvr.v72i1.222] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
Ingestion of the plant Nolletia gariepina was confirmed as the cause of acute mortalities in cattle in the Kuruman area of the Northern Cape Province of South Africa. The aim of this trial was to investigate the toxic effects of this plant with respect to clinical signs, pathophysiology and pathology using the sheep as a model. At dosages of 1.5 g dried, milled plant material/kg body mass there were no detectable abnormal findings, while at dosages of 2.8-3.0 g/kg most of the animals died acutely. In subacutely affected sheep, depression, inappetance, teeth grinding, tachycardia, weak ruminal movements and recumbency were noticed. The most prominent pathophysiological changes observed, included a sharp rise in non-protein nitrogen substances in the plasma, remarkable decline in glomerular filtration rate, increase in sodium and potassium excretion, and a rise in urine gamma glutamyltransferase activity. Macroscopically a severe nephrosis was present in all the animals. The most important findings detected histologically were necrosis of the proximal convoluted tubular epithelium and large numbers of protein casts in the lumens.
Collapse
Affiliation(s)
- R A Meintjes
- Department of Anatomy and Physiology, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, South Africa.
| | | | | |
Collapse
|
39
|
Finco DR. Measurement of glomerular filtration rate via urinary clearance of inulin and plasma clearance of technetium Tc 99m pentetate and exogenous creatinine in dogs. Am J Vet Res 2005; 66:1046-55. [PMID: 16008230 DOI: 10.2460/ajvr.2005.66.1046] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare glomerular filtration rate (GFR) measured via urinary clearance of inulin (UCI) with plasma clearance of technetium Tc 99m pentetate (99mTc-pentetate) and creatinine in dogs. ANIMALS 6 healthy Beagles and 18 Beagles with reduced renal function. PROCEDURE 13 blood samples were obtained between 5 and 600 minutes after i.v. bolus injections of (99m)Tc-pentetate and creatinine. Plasma clearance of (99m)Tc-pentetate was computed on the basis of 1, 2, or 13 samples, and plasma clearance of creatinine was computed on the basis of 2, 5, or 13 samples. During plasma clearance procedures, constant i.v. infusion of carboxyl carbon 14 inulin was begun and UCI was determined in urine collected from 90 to 120, 120 to 180, and 180 to 240 minutes. Clearance procedures were repeated in 12 dogs to evaluate reproducibility of results. RESULTS Significant association between UCI and plasma clearance was determined via all methods. However, plasma clearances were moderately to markedly different from UCI, depending on test substance, GFR, and sample numbers used for plasma clearance computations. Comparisons were particularly discordant when some methods of limiting samples were used to define plasma clearance. CONCLUSIONS AND CLINICAL RELEVANCE Values derived from plasma clearance methods for (99m)Tc-pentetate and creatinine were not interchangeable with UCI results, which raises questions about their reliability as clinical research tools for measurement of GFR. Plasma clearance methods that are relative indices of renal function should not be interpreted as accurate measures of GFR without validation.
Collapse
Affiliation(s)
- Delmar R Finco
- Department of Physiology and Pharmacology, College of Veterinary Medicine, The University of Georgia, Athens, GA 30602, USA
| |
Collapse
|
40
|
Bolliger C, Walshaw R, Kruger JM, Rosenstein DS, Richter MA, Hauptman JG, Mauer WA. Evaluation of the effects of nephrotomy on renal function in clinically normal cats. Am J Vet Res 2005; 66:1400-7. [PMID: 16173484 DOI: 10.2460/ajvr.2005.66.1400] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To evaluate the effects of nephrotomy on renal function in clinically normal cats. ANIMALS 20 specific-pathogen-free, 9- to 11-month-old female mixed-breed cats. PROCEDURE Serum chemistry analyses, CBC determinations, urinalyses, microbiologic urine cultures, renal ultrasonography, abdominal radiography, and single-kidney and total glomerular filtration rate (GFR) determinations by use of renal scintigraphy and measurements of plasma disappearance of technetium 99m-diethylenetriaminepentaacetic acid were performed before surgery and at 3, 12, 26, 52, and 78 weeks after surgery in 10 cats that underwent unilateral nephrotomy and in 10 control cats that underwent a sham surgical procedure. RESULTS Two cats (1 from each group) did not complete the study, and their data were eliminated from analyses. Unilateral nephrotomy resulted in a 10% to 20% reduction in mean single-kidney GFR, compared with that of nephrotomy contralateral control kidneys. However, mean total GFR in nephrotomy-group cats was not significantly different from that of sham-group cats. Over the 78 weeks of study, mean total GFR declined 34% and 40% in nephrotomy- and sham-group cats, respectively. Adverse events associated with nephrotomy included persistent microscopic hematuria, renal pelvis hyperechogenicity with distant shadowing on ultrasonographic evaluation, dilatation of renal pelves, and hydronephrosis. CONCLUSIONS AND CLINICAL RELEVANCE Nephrotomy in normal functioning feline kidneys results in a modest relative reduction in renal function, compared with contralateral kidney controls, but has minimal effect on total GFR when compared with sham-operated control cats. However, any detrimental effects of nephrotomy may be magnified in cats with diseased kidneys, which may have little or no capacity for repair or compensation.
Collapse
Affiliation(s)
- Christian Bolliger
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, MI 48824, USA
| | | | | | | | | | | | | |
Collapse
|
41
|
Saleh N, Aoki M, Shimada T, Akiyoshi H, Hassanin A, Ohashi F. Renal effects of medetomidine in isoflurane-anesthetized dogs with special reference to its diuretic action. J Vet Med Sci 2005; 67:461-5. [PMID: 15942129 DOI: 10.1292/jvms.67.461] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Renal effects of the selective alpha(2)-adrenoceptor agonist, medetomidine, were investigated in anesthetized dogs. Animals were administered medetomidine 20 and 40 microg/kg intravenously (IV) and 80 mug/kg intramuscularly (IM) or 1 ml of saline IV. Urine and blood samples were collected before and at 30, 60, 90 and 120 min following medetomidine injection. Mean arterial blood pressure (MABP), renal blood flow (RBF), glomerular filtration rate (GFR), urine volume (U(v)), urine osmolality (U(osm)), free water clearance (C(H2O)), fractional clearance of sodium (F(Na)), plasma osmolality (P(osm)), plasma glucose levels and plasma antidiuretic hormone (ADH) concentrations were measured. The results showed that IV administration of medetomidine initially increased MABP 5-15 min followed by long-lasting decrease. The initial hypertension was not observed after IM administration, which was accompanied by a more profound hypotensive effects. RBF, GFR, U(v), C(H2O) increased after IV injection and decreased after IM. Medetomidine increased FNa and Posm and decreased U(osm). Plasma glucose levels initially increased and subsequently decreased. Plasma ADH concentration was decreased by IV injection but increased by IM administration. Our data imply that: 1) IV administration of medetomidine at dose rates of 20 and 40 microg/kg results in profound diuresis up to 2 hr; 2) Suppression of ADH release from the CNS is one of the mechanisms of medetomidine-induced diuresis although it may not be the principal one.
Collapse
Affiliation(s)
- Nahed Saleh
- Laboratory of Veterinary Surgery, Graduate School of Agriculture and Biological Sciences, Osaka Prefecture University, 1-1 Gakuen-cho, Sakai-shi, Osaka 599-8531, Japan
| | | | | | | | | | | |
Collapse
|
42
|
Hernandez-Divers SJ, Stahl SJ, Stedman NL, Hernandez-Divers SM, Schumacher J, Hanley CS, Wilson H, Vidyashankar AN, Zhao Y, Rumbeiha WK. RENAL EVALUATION IN THE HEALTHY GREEN IGUANA (IGUANA IGUANA): ASSESSMENT OF PLASMA BIOCHEMISTRY, GLOMERULAR FILTRATION RATE, AND ENDOSCOPIC BIOPSY. J Zoo Wildl Med 2005; 36:155-68. [PMID: 17323554 DOI: 10.1638/03-120.1] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Plasma biochemistry, iohexol clearance, endoscopic renal evaluation, and biopsy were performed in 23 clinically healthy 2-yr-old green iguanas (Iguana iguana). Mean (+/- SD) values for packed cell volume (30 +/- 3%), total protein (62 +/- 7 g/L, 6.2 +/- 0.7 g/dl), albumin (25 +/- 2 g/L, 2.5 +/- 0.2 g/dl), globulin (37 +/- 6 g/L, 3.7 +/- 0.6 g/ dl), total calcium (3.0 +/- 0.2 mmol/L, 12.0 +/- 0.7 mg/dl), ionized calcium (1.38 +/- 0.1 mmol/L), phosphorus (1.32 +/- 0.28 mmol/L, 4.1 +/- 0.9 mg/dl), uric acid (222 +/- 100 micromol/L, 3.8 +/- 1.7 mg/dl), sodium (148 +/- 3 mmol/L or mEq/ L), and potassium (2.6 +/- 0.4 mmol/L or mEq/L) were considered within normal limits. Values for urea were low (< 1.4 mmol/L, < 4 mg/dl) with 70% of samples below the detectable analyzer range. After the i.v. injection of 75 mg/ kg iohexol into the caudal (ventral coccygeal or tail) vein, serial blood collections were performed over 32 hr. Iohexol assays by high-performance liquid chromatography produced plasma iohexol clearance graphs for each lizard. A three-compartment model was used to fit area under the curve values and to obtain the glomerular filtration rate (GFR) using regression analysis. The mean GFR (SD) was 16.56 +/- 3.90 ml/kg/hr, with a 95% confidence interval of 14.78-18.34 ml/kg/hr. Bilateral endoscopic renal evaluation and biopsy provided tissue samples of excellent diagnostic quality, which correlated with tissue harvested at necropsy and evaluated histologically. None of the 23 animals demonstrated any adverse effects of iohexol clearance or endoscopy. Recommended diagnostics for the evaluation of renal function and disease in the green iguana include plasma biochemical profiles, iohexol clearance, endoscopic examination, and renal biopsy.
Collapse
Affiliation(s)
- Stephen J Hernandez-Divers
- Exotic Animal, Wildlife and Zoological Medicine Service, Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, Athens, Georgia 30602, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Abstract
Clinical evaluation of early renal dysfunction is problematic in the nonazotemic animal. Measurement of glomerular filtration rate (GFR) provides the most accurate assessment of renal function. However, many methods of determining GFR are not practical for use in routine veterinary practice. This article provides a description and literature review of methods to determine GFR, including benefits and drawbacks of each method for the practicing veterinarian.
Collapse
Affiliation(s)
- Marie E Kerl
- College of Veterinary Medicine, University of Missouri--Columbia, Columbia, Missouri 65211, USA.
| | | |
Collapse
|
44
|
Abstract
Previous trials have demonstrated that sheep on a low protein diet and free access to water, and sheep dosed with boluses of NaCl intraruminally also with free access to water, showed decreases in urea loss via the urine compared to control animals. We monitored urea excretion in sheep on a relatively poor protein diet when they were exposed to saline drinking water, i.e. they were unable to vary their intake of NaCl:water. Sheep on isotonic saline drinking water (phase 3) excreted significantly more urea via the urine (284 mM/day) compared to phase 1 when they were on non-saline drinking water (urea excretion = 230 mM/day) and phase 2 when they were on half isotonic saline drinking water (urea excretion = 244 mM/day).This finding was explained by the high glomerular filtration rate (GFR) 91.9 ℓ/day, compared to 82.4 ℓ/day (phase 1) and 77.9 ℓ/day (phase 2), together with a significantly raised fractional excretion of urea (FEurea) (51.1 %) during this phase, and was in spite of the significantly lower plasma concentrations of urea in phase 3 compared to phase 1. The FEurea probably results from the osmotic diuresis caused by the salt. There were indications of a raised plasma antidiuretic hormone (ADH) concentration and this would have opposed urea loss, as ADH promotes urea reabsorption. However, this ADH effect was probably counteracted to some extent by a low plasma angiotensin II concentration, for which again there were indications, inhibiting urea reabsorption during the phases of salt loading. As atrial natriuretic peptide both increases GFR and decrease sodium reabsorption from the tubule, it was probably instrumental in causing the increase in GFR and the increase in the fractional excretion of sodium (FENa).
Collapse
Affiliation(s)
- R A Meintjes
- Department of Anatomy and Physiology, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110 South Africa
| | | |
Collapse
|
45
|
Bailey DB, Rassnick KM, Erb HN, Dykes NL, Hoopes PJ, Page RL. Effect of glomerular filtration rate on clearance and myelotoxicity of carboplatin in cats with tumors. Am J Vet Res 2004; 65:1502-7. [PMID: 15566088 DOI: 10.2460/ajvr.2004.65.1502] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To characterize the pharmacokinetic disposition of carboplatin and determine whether glomerular filtration rate (GFR) could be used to predict carboplatin clearance and myelotoxic effects in cats with tumors. ANIMALS 10 cats with tumors. PROCEDURE Glomerular filtration rate was assessed in each cat by monitoring plasma clearance of technetium Tc 99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Each cat received carboplatin (200 mg/m2 of body surface area) administered as an IV bolus. Plasma platinum concentrations were measured via atomic absorption spectrophotometry, and pharmacokinetic analysis was performed. A CBC was performed weekly for each cat, and the correlation between the area under the concentration-versus-time curve (AUC) and the severity of myelosuppression was calculated. Least squares regression analysis was performed to determine whether GFR could be used to predict plasma platinum clearance (ClPt). RESULTS For all cats, AUC measurements ranged from 0.99 to 4.30 min x mg x mL(-1). Neutrophil concentration nadirs were detected 1 to 3 weeks after treatment and ranged from 200 to 8,000 cells/microl. The absolute neutrophil concentration at the nadir was inversely correlated with AUC. The ClPt was predicted by use of GFR measurements (ClPt = 2.60 x GFR). A carboplatin dose prescription model was derived involving AUC, estimated ClPt, and body weight in kilograms (BWkg), in which dose = AUC x 2.60(GFR) x BWkg. CONCLUSIONS AND CLINICAL RELEVANCE In cats, an individualized prescription strategy for carboplatin administration based on a targeted AUC and determination of GFR might more uniformly predict myelosuppression than that predicted by conventional dosing based on body surface area.
Collapse
Affiliation(s)
- Dennis B Bailey
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | | | | | | | | | | |
Collapse
|
46
|
Höchel J, Finnah A, Velde K, Hartmann H. [Evaluation of a modified exogenous creatinine clearance as a suitable renal function test for the small animal practice]. Berl Munch Tierarztl Wochenschr 2004; 117:420-7. [PMID: 15495934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/01/2023]
Abstract
A suitable method in the routine veterinary practice for the quantitative determination of the glomerular filtration rate (GFR) in dogs and cats has not been available until to date. Therefore, we modified the known plasma clearance model (=P-CL). The resulting P-CLterminal was assessed concerning its diagnostic value. P-CL of exogenous creatinine (P-CLcrea) and of inulin were determined in dogs (n=12, Beagle, 6 months of age) and cats (n=11, Domestic Short Hair, 14 months of age). The marker substances were administered as a bolus injection. In fasted dogs, P-CLcrea was 84.3 +/- 14.85 ml/min/m2 after a creatinine dose of 2.4 g/m2. An electrolyte infusion during the clearance determination did not alter the resulting values (p>0.05). In fasted cats, P-CLcrea was 54.7 +/- 5.8 ml/min/m2 (creatinine dose 2.0 g/m2). The inulin clearance, determined at the same time, was 104.5 +/- 19.81 ml/min/m2. Feeding the cats just before and during the test increased P-CL of both markers significantly (p<0.05). In order to adapt the clearance method for diagnostic assessment of GFR in the small animal practice, we aimed at minimizing the number of required blood samples (3 instead of 7 or more) and introduced the modified exogenous creatinine clearance (P-CLterminal). These values determined were 108.4 +/- 20.81 ml/min/m2 in fasted dogs and 66.3 +/- 11.81 ml/min/m2 in fasted cats. An electrolyte infusion (dogs) and feeding (cats) had the same effect on P-CLterminal values as described above for P-CL. In conclusion,the modified exogenous creatinine clearance is a suitable renal function test for the early diagnosis of renal disease in dogs and cats presented in small animal practices.
Collapse
Affiliation(s)
- Joachim Höchel
- Institut für Veterinär-Physiologie, Fachbereich Veterinärmedizin der Freien Universität Berlin, Berlin
| | | | | | | |
Collapse
|
47
|
Abstract
Systemic hypertension is hypothesized to cause renal injury to dogs. This study was performed on dogs with surgically induced renal failure to determine whether hypertension was associated with altered renal function or morphology. Mean arterial pressure (MAP), heart rate (HR), systolic arterial pressure (SAP), and diastolic arterial pressure (DAP) were measured before and after surgery. Glomerular filtration rate (GFR) and urine protein:creatinine ratios (UPC) were measured at 1, 12, 24, 36, and 56-69 weeks after surgery, and renal histology was evaluated terminally. The mean of weekly MAP, SAP, and DAP measurements for each dog over the 1st 26 weeks was used to rank dogs on the basis of MAP, SAP, or DAP values. A statistically significant association was found between systemic arterial pressure ranking and ranked measures of adverse renal responses. When dogs were divided into higher pressure and lower pressure groups on the basis of SAP, group 1 (higher pressure, n = 9) compared with group 2 (lower pressure, n = 10) had significantly lower GFR values at 36 and 56-69 weeks; higher UPC values at 12 and 56-69 weeks; and higher kidney lesion scores for mesangial matrix, tubule damage, and fibrosis. When dogs were divided on MAP and DAP values, group 1 compared with group 2 had significantly lower GFR values at 12, 24, 36, and 56-69 weeks; higher UPC values at 12 and 56-69 weeks; and higher kidney lesion scores for mesangial matrix, tubule damage, fibrosis, and cell infiltrate. These results demonstrate an association between increased systemic arterial pressure and renal injury. Results from this study might apply to dogs with some types of naturally occurring renal failure.
Collapse
Affiliation(s)
- Delmar R Finco
- Department of Physiology and Pharmacology, College of Veterinary Medicine, The University of Georgia, Athens, GA 30602, USA.
| |
Collapse
|
48
|
Abstract
Serum urea and creatinine are extensively used as parameters to screen for azotaemia. Their reciprocal plots roughly correlate with glomerular filtration rate (GFR). They are, however, subject to influence by non-renal factors and to increase their specificity they are often tested concurrently. In renal disease they are expected to behave similarly, with both parameters increasing as GFR decreases. Haemolysis, as it occurs in canine babesiosis, may cause non-renal elevations in serum urea, possibly due to ammonia loading. Furthermore, haemolysis with its related elevations in serum bilirubin and serum haemoglobin, may negatively bias the measurement of serum creatinine due to interference of these substances with the chemical analysis of serum creatinine. This negative bias occurs when the alkaline picrate method, or when direct enzymatic methods based on the measurement of hydrogen peroxide, are used. In order to investigate the significance of these perturbations in canine babesiosis, paired values of serum urea and serum creatinine from Babesia canis-negative, non-haemolysis dogs (Group 1), were used to establish a relationship between urea and creatinine over a range of azotaemia by linear regression analysis. This relationship was then used to predict serum creatinine values from actual serum urea values in B. canis-positive dogs (Group 2). The mean of the predicted serum creatinine values for Group 2 (237.03 mmol/ℓ) was then compared with the mean of the actual serum creatinine values for Group 2 (131.31 mmol/ℓ). For Group 2, themeanactual serumcreatinine demonstrated a significant negative bias relative to the mean predicted creatinine value. There was also a higher correlation between serum urea and serum creatinine in Group 1 than in Group 2. These findings may have been caused by either nonrenal elevations of serum urea values or by interference with the measurement of serum creatinine. Therefore, although it is possible that some Group 2 dogs with B. canis with high serum urea and normal, low, or zero values for serumcreatinine were not azotaemic, it is also possible that other Group 2 dogs with these biochemical findings did in fact have azotaemia. This study concluded that urea and creatinine do not behave in a similar and predictable manner over a range of azotaemia in canine babesiosis and are therefore not ideally suited for the detection of renal disease in this clinical setting.
Collapse
Affiliation(s)
- M P de Scally
- Bryanston Veterinary Hospital, P.O. Box 67092, Bryanston, 2021 South Africa.
| | | | | | | |
Collapse
|
49
|
Holder EH, Citino SB, Businga N, Cartier L, Brown SA. MEASUREMENT OF GLOMERULAR FILTRATION RATE, RENAL PLASMA FLOW, AND ENDOGENOUS CREATININE CLEARANCE IN CHEETAHS (ACINONYX JUBATUS JUBATUS). J Zoo Wildl Med 2004; 35:175-8. [PMID: 15305512 DOI: 10.1638/02-022] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Glomerular filtration rate (GFR), renal plasma flow (RPF), and the endogenous creatinine clearance (CCr) rate were determined in 13 captive cheetahs, Acinonyx jubatus jubatus (seven females and six males, 1.5-7.5 yr of age, x = 5.02 yr), during general anesthesia with Telazol and isoflurane by measuring the urinary clearances of inulin, para-aminohipppuric acid, and endogenous creatinine, respectively. Methods to determine GFR, RPF, and endogenous CCr in captive cheetahs were evaluated, and the relationship between GFR and CCr for this species was determined. The GFR and the RPF were stable during the procedure, with mean values of 1.59+/-0.17 ml/min/kg body weight and 5.12+/-1.15 ml/min/kg body weight, respectively. Although the mean value for CCr (1.47+/-0.20 ml/min/kg body weight) was significantly less than the corresponding value for GFR, the mean difference (0.11+/-0.02 ml/min/kg weight) between the two measurements was slight, and the values were highly correlated (R2 = 0.928; P < 0.0001). The measurement of CCr in cheetahs should provide a reliable estimate of GFR, facilitating the early detection of renal disease in this species.
Collapse
|
50
|
Abstract
Ten healthy mixed-breed dogs were used to evaluate the functional and structural effects of serial ultrasound-guided renal biopsies obtained with an automated biopsy needle. In each dog, one lateral renal cortex was biopsied at 2, 4, and 6 months of age; the other kidney was the control. Five dogs had two tissue cores and five dogs had four tissue cores taken on each biopsy occasion, and one core was examined microscopically. One week before each biopsy and a month after the final biopsy, the glomerular filtration rate (GFR) was determined by renal scintigraphy. Dogs were then euthanized for evaluation of gross and microscopic lesions attributable to the biopsies. There was no difference between GFR values for biopsied kidneys and those of control kidneys (P > 0.05). Microscopic lesions were not identified in biopsies taken at 2 and 4 months, but focal lesions were found in three of 10 specimens taken at 6 months of age. At necropsy, six of 10 biopsied kidneys had small visible capsular scars, and linear tracts < 2 mm wide were observed on cut surfaces in six of 10 biopsied kidneys cut transversely into slices 5 mm thick. Discrete light microscopic lesions were observed in 25 of 452 (5.5%) of randomly selected 6-mm-diameter sections of renal cortex from biopsied kidneys. We conclude that serial renal cortical biopsies can be obtained by our method from healthy adolescent dogs with minimal risk of inducing changes that might be confused with those of a progressive renal disease.
Collapse
Affiliation(s)
- Reid P Groman
- Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, Texas A&M University, College Station, TX 77843-4474, USA
| | | | | | | |
Collapse
|