1
|
Nagase K, Suzuki S, Kanazawa H. Temperature-modulated interactions between thermoresponsive strong cationic copolymer-brush-grafted silica beads and biomolecules. Heliyon 2024; 10:e34668. [PMID: 39161811 PMCID: PMC11332852 DOI: 10.1016/j.heliyon.2024.e34668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 07/05/2024] [Accepted: 07/15/2024] [Indexed: 08/21/2024] Open
Abstract
Thermoresponsive polymer brushes have attracted considerable research attention owing to their unique properties. Herein, we developed silica beads grafted with poly(N-isopropylacrylamide (NIPAAm)-co-3-acrylamidopropyl trimethylammonium chloride (APTAC)-co-tert-butyl acrylamide (tBAAm) and P(NIPAAm-co-APTAC-co-n-butyl methacrylate(nBMA)) brushes. The carbon, hydrogen, and nitrogen elemental analysis of the copolymer-grated silica beads revealed the presence of a large amount of the grafted copolymer on the silica beads. The electrostatic and hydrophobic interactions between biomolecules and prepared copolymer brushes were analyzed by observing their elution behaviors via high-performance liquid chromatography using the copolymer-brush-modified beads as the stationary phase. Adenosine nucleotides were retained in the bead-packed columns, which was attributed to the electrostatic interaction between the copolymers and adenosine nucleotides. Insulin was adsorbed on the copolymer brushes at high temperatures, which was attributed to its electrostatic and hydrophobic interactions with the copolymer. Similar adsorption behavior was observed in case of albumin. Further, at a low concentration of the phosphate buffer solution, albumin was adsorbed onto the copolymer brushes even at relatively low temperatures owing to its enhanced electrostatic interaction with the copolymer. These results indicated that the developed thermoresponsive strong cationic copolymer brushes can interact with peptides and proteins through a combination of electrostatic and temperature-modulated hydrophobic interactions. Thus, the developed copolymer brushes exhibits substantial potential for application in chromatographic matrices for the analysis and purification of peptides and proteins.
Collapse
Affiliation(s)
- Kenichi Nagase
- Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| | - Sayaka Suzuki
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| | - Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| |
Collapse
|
2
|
Nagase K. Bioanalytical technologies using temperature-responsive polymers. ANAL SCI 2024; 40:827-841. [PMID: 38584205 PMCID: PMC11035477 DOI: 10.1007/s44211-024-00545-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 02/24/2024] [Indexed: 04/09/2024]
Abstract
In recent decades, various bioanalytical technologies have been investigated for appropriate medical treatment and effective therapy. Temperature-responsive chromatography is a promising bioanalytical technology owing to its functional properties. Temperature-responsive chromatography uses a poly(N-isopropylacrylamide)(PNIPAAm) modified stationary phase as the column packing material. The hydrophobic interactions between PNIPAAm and the analyte could be modulated by changing the column temperature because of the temperature-responsive hydrophobicity of PNIPAAm. Thus, the chromatography system does not require organic solvents in the mobile phase, making it suitable for therapeutic drug monitoring in medical settings such as hospitals. This review summarizes recent developments in temperature-responsive chromatography systems for therapeutic drug monitoring applications. In addition, separation methods for antibody drugs using PNIPAAm are also summarized because these methods apply to the therapeutic drug monitoring of biopharmaceutics. The temperature-responsive chromatography systems can also be utilized for clinical diagnosis, as they can assess multiple medicines simultaneously. This highlights the significant potential of temperature-responsive chromatography in medicine and healthcare.
Collapse
Affiliation(s)
- Kenichi Nagase
- Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8553, Japan.
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan.
| |
Collapse
|
3
|
Nagase K, Ishii S, Takeuchi A, Kanazawa H. Temperature-modulated antibody drug separation using thermoresponsive mixed polymer brush-modified stationary phase. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.121750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
4
|
A Multiple-Stimuli-Responsive Amphiphilic Copolymer for Antifouling and Antibacterial Functionality via a “Resistance–Kill–Release” Mechanism. Molecules 2022; 27:molecules27165059. [PMID: 36014312 PMCID: PMC9416764 DOI: 10.3390/molecules27165059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 07/30/2022] [Accepted: 08/08/2022] [Indexed: 11/21/2022] Open
Abstract
In recent years, polymers with stimuli-responsive properties have been increasingly reported on due to their diverse applications. However, most of the studies have only focused on the performance of polymers under specific scenarios. The laws of changes in the properties in response to various external stimuli have been less systematically and quantitatively studied. In this paper, we prepared an amphiphilic polymer (PadaMX and PAdaM3QA−X) with temperature-, pH-, ion-, and β-cyclodextrin (β-CD)-responsive properties. According to the cloud point tested by the UV-Vis method, the lower critical soluble temperature (LCST) of PAdaM3QA−10% was more sensitive to a change in pH and less sensitive to a change in ions compared with PadaM3 due to quaternized side chains with a stronger intramolecular mutual repulsion. We then fabricated the coatings with responsive properties by immobilizing the adamantyl groups on β-CD-modified surfaces. The hydrophilicity of the coatings was improved after quaternization, as proven by the water contact angle (WCA) measurement. The antifouling and antibacterial performance was further evaluated via the fluorescence intensity of bovine serum albumin (BSA) adsorbed on the surfaces and the spread plate method. A 78.4% BSA desorption rate and a 96.8% sterilization rate were achieved by the PAdaM3QA−10% coating. In summary, this work prepared a multiple-stimuli-responsive amphiphilic copolymer for antifouling and antibacterial functionality via a “resistance–kill–release” mechanism.
Collapse
|
5
|
Nagase K, Kitazawa S, Kogure T, Yamada S, Katayama K, Kanazawa H. Viral vector purification with thermoresponsive-anionic mixed polymer brush modified beads-packed column. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.120445] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
6
|
Nagase K, Matsumoto K, Kanazawa H. Temperature-responsive mixed-mode column for the modulation of multiple interactions. Sci Rep 2022; 12:4434. [PMID: 35292748 PMCID: PMC8924202 DOI: 10.1038/s41598-022-08475-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 03/08/2022] [Indexed: 01/13/2023] Open
Abstract
In this study, mixed-mode chromatography columns have been investigated using multiple analyte interactions. A mixed-mode chromatography column was developed using poly(N-isopropylacrylamide) (PNIPAAm) brush-modified silica beads and poly(3-acrylamidopropyl trimethylammonium chloride) (PAPTAC) brush-modified silica beads. PNIPAAm brush-modified silica beads and PAPTAC brush-modified silica beads were prepared by atom transfer radical polymerization. The beads were then packed into a stainless-steel column in arbitrary compositions. The elution studies evaluated the column performance on hydrophobic, electrostatic, and therapeutic drug samples using steroids, adenosine nucleotide, and antiepileptic drugs as analytes, respectively. Steroids exhibited an increased retention time when the column temperature was increased. The retention of adenosine nucleotides increased with the increasing composition of the PAPTAC-modified beads in the column. The antiepileptic drugs were separated using the prepared mixed-mode columns. An effective separation of antiepileptic drugs was observed on a 10:1 PNIPAAm:PAPTAC column because the balance between the hydrophobic and electrostatic interactions with antiepileptic drugs was optimized for the bead composition. Oligonucleotides were also separated using mixed-mode columns through multiple hydrophobic and electrostatic interactions. These results demonstrate that the developed mixed-mode column can modulate multiple hydrophobic and electrostatic interactions by changing the column temperature and composition of the packed PNIPAAm and PAPTAC beads.
Collapse
Affiliation(s)
- Kenichi Nagase
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan.
| | - Kosuke Matsumoto
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| | - Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| |
Collapse
|
7
|
Baert M, Wicht K, Moussa A, Desmet G, Broeckhoven K, Lynen F. Implementations of temperature gradients in temperature-responsive liquid chromatography. J Chromatogr A 2021; 1654:462425. [PMID: 34425285 DOI: 10.1016/j.chroma.2021.462425] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/09/2021] [Accepted: 07/13/2021] [Indexed: 11/16/2022]
Abstract
Temperature Responsive Liquid Chromatography (TRLC) offers an alternative and environmentally friendly way to perform reversed-phase like separations. Its use of temperature responsive polymers to control retention based on column temperature, instead of the fraction of organic modifier in the mobile phase mobile, eliminates the need for solvent composition gradients and allows, for example, for purely aqueous separations. In principle this temperature induced retention should allow for gradient elutions to be performed using downward temperature gradients to control retention and refocus the analyte peaks. Yet, the unavailability of dedicated commercial temperature controlling systems allowing suitable temperature control in TRLC limits implementations thereof often to isothermal or step gradient applications. In this work we study the potential of 1) a simple yet programmable water bath and of 2) a modified HPLC system allowing column temperature programming through controlled mixing of a warm and cold mobile phase streams. The performance of both systems was evaluated under both isocratic and gradient applications, resulting in a more thorough understanding of the influence of temperature gradients in TRLC. This knowledge is then applied to a sample of phenolic solutes, illustrating that, although both systems have some flaws, both are able to impose temperature gradients in TRLC resulting in significantly reduced retention and enhanced refocusing of the analyte peak.
Collapse
Affiliation(s)
- Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4bis, Ghent B-9000, Belgium
| | - Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4bis, Ghent B-9000, Belgium
| | - Ali Moussa
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussel B-1050, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussel B-1050, Belgium
| | - Ken Broeckhoven
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussel B-1050, Belgium
| | - Frederic Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4bis, Ghent B-9000, Belgium.
| |
Collapse
|
8
|
Nagase K. Thermoresponsive interfaces obtained using poly(N-isopropylacrylamide)-based copolymer for bioseparation and tissue engineering applications. Adv Colloid Interface Sci 2021; 295:102487. [PMID: 34314989 DOI: 10.1016/j.cis.2021.102487] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 07/09/2021] [Accepted: 07/10/2021] [Indexed: 12/11/2022]
Abstract
Poly(N-isopropylacrylamide) (PNIPAAm) is the most well-known and widely used stimuli-responsive polymer in the biomedical field owing to its ability to undergo temperature-dependent hydration and dehydration with temperature variations, causing hydrophilic and hydrophobic alterations. This temperature-dependent property of PNIPAAm provides functionality to interfaces containing PNIPAAm. Notably, the hydrophilic and hydrophobic alterations caused by the change in the temperature-responsive property of PNIPAAm-modified interfaces induce temperature-modulated interactions with biomolecules, proteins, and cells. This intrinsic property of PNIPAAm can be effectively used in various biomedical applications, particularly in bioseparation and tissue engineering applications, owing to the functionality of PNIPAAm-modified interfaces based on the temperature modulation of the interaction between PNIPAAm-modified interfaces and biomolecules and cells. This review focuses on PNIPAAm-modified interfaces in terms of preparation method, properties, and their applications. Advances in PNIPAAm-modified interfaces for existing and developing applications are also summarized.
Collapse
Affiliation(s)
- Kenichi Nagase
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo 105-8512, Japan.
| |
Collapse
|
9
|
Nagase K, Umemoto Y, Kanazawa H. Effect of pore diameter on the elution behavior of analytes from thermoresponsive polymer grafted beads packed columns. Sci Rep 2021; 11:9976. [PMID: 33976250 PMCID: PMC8113370 DOI: 10.1038/s41598-021-89165-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 04/21/2021] [Indexed: 02/07/2023] Open
Abstract
Temperature-responsive chromatography using thermoresponsive polymers is innovative and can control analyte retention via column temperature. Analyte elution behavior in this type of chromatography depends on the modified thermoresponsive polymer and the structure of the base materials. In the present study, we examine the effect of the pore diameter of silica beads on analyte elution behavior in temperature-responsive chromatography. Poly(N-isopropylacrylamide-co-n-butyl methacrylate) hydrogel was applied to beads of various pore sizes: 7, 12, and 30 nm. Almost the same amount of copolymer hydrogel was applied to all beads, indicating that the efficiency of copolymer modification was independent of pore size. Analyte retention on prepared beads in a packed column was observed using steroids, benzodiazepines, and barbiturates as analytes. Analyte retention times increased with temperature on packed columns of 12- and 30-nm beads, whereas the column packed with 7-nm beads exhibited decreased retention times with increasing temperature. The difference in analyte elution behavior among the various pore sizes was attributed to analyte diffusion into the bead pores. These results demonstrate that bead pore diameter determines temperature-dependent elution behavior.
Collapse
Affiliation(s)
- Kenichi Nagase
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan.
| | - Yuta Umemoto
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| | - Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo, 105-8512, Japan
| |
Collapse
|
10
|
Gu H, Liu Y, Wang L, Zhang B, Yin D, Zhang Q. Polymer
brush‐grafted
monolithic macroporous
polyHIPEs
obtained by
surface‐initiated ARGET ATRP
and heparinized for Enterovirus 71 purification. J Appl Polym Sci 2020. [DOI: 10.1002/app.50427] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Huimin Gu
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an China
| | - Yibin Liu
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an China
| | - Lichun Wang
- Institute of Medical Biology Chinese Academy of Medical Sciences Kun'ming China
| | - Baoliang Zhang
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an China
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology Northwestern Polytechnical University Xi'an China
| | - Dezhong Yin
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an China
| | - Qiuyu Zhang
- School of Chemistry and Chemical Engineering Northwestern Polytechnical University Xi'an China
- Key Laboratory of Special Functional and Smart Polymer Materials of Ministry of Industry and Information Technology Northwestern Polytechnical University Xi'an China
| |
Collapse
|
11
|
Nagase K, Kanazawa H. Temperature-responsive chromatography for bioseparations: A review. Anal Chim Acta 2020; 1138:191-212. [DOI: 10.1016/j.aca.2020.07.075] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 07/29/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023]
|
12
|
Nagase K, Watanabe M, Zen F, Kanazawa H. Temperature-responsive mixed-mode column containing temperature-responsive polymer-modified beads and anionic polymer-modified beads. Anal Chim Acta 2019; 1079:220-229. [DOI: 10.1016/j.aca.2019.06.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 05/18/2019] [Accepted: 06/04/2019] [Indexed: 10/26/2022]
|
13
|
Mixed polymer brush as a functional ligand of silica beads for temperature-modulated hydrophobic and electrostatic interactions. Anal Chim Acta 2019; 1095:1-13. [PMID: 31864610 DOI: 10.1016/j.aca.2019.10.058] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Revised: 10/21/2019] [Accepted: 10/24/2019] [Indexed: 11/23/2022]
Abstract
We developed a mixed polymer brush, which consists of temperature-responsive polymer and cationic polymer modified beads as functional chromatographic matrices, for temperature-modulated multiple hydrophobic and electrostatic interactions. The mixed polymer brush was modified on silica beads through the combination of reversible addition-fragmentation chain transfer (RAFT) polymerization of N,N-dimethylaminopropyl acrylamide (DMAPAAm) and surface initiated atom transfer radical polymerization (ATRP) of N-isopropylacrylamide (NIPAAm). Zeta potential measurement of the mixed polymer brush revealed that the zeta potential increased with increasing temperature, which was attributed to the exposed PDMAPAAm on the beads arising from the shrinking of PNIPAAm upon increasing the temperature. The prepared beads were used as the packing material of high performance liquid chromatography (HPLC) columns, and the elution behavior of steroids, adenosine nucleotides, and proteins through the column was observed. The retention time of steroids increased with increasing the column temperature because of the dehydration of PNIPAAm in the mixed polymer brush. Adenosine nucleotides were also retained by the columns, which was attributed to the electrostatic interaction with PDMAPAAm in the mixed polymer brush. Several proteins were adsorbed on the column at elevated temperatures because of the enhanced electrostatic interaction of exposed PDMAPAAm and the enhanced hydrophobic interaction resulting from the dehydration of PNIPAAm. By exploiting this unique property, mixtures of proteins could be separated by simply changing the column temperature. These results indicate that the developed mixed polymer brush modified beads would be useful as functional chromatographic packing matrices for thermally-modulated multiple hydrophobic and electrostatic interactions.
Collapse
|
14
|
Nagase K, Okano T, Kanazawa H. Poly(N-isopropylacrylamide) based thermoresponsive polymer brushes for bioseparation, cellular tissue fabrication, and nano actuators. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.nanoso.2018.03.010] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
15
|
NAGASE K, OKANO T, KANAZAWA H. Design of Functional Thermoresponsive Polymer Brushes and Their Application to Bioseparation. KOBUNSHI RONBUNSHU 2018. [DOI: 10.1295/koron.2017-0073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
| | - Teruo OKANO
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women’s Medical University, TWIns
- Cell Sheet Tissue Engineering Center (CSTEC) and Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah
| | | |
Collapse
|
16
|
Nagase K, Yamato M, Kanazawa H, Okano T. Poly(N-isopropylacrylamide)-based thermoresponsive surfaces provide new types of biomedical applications. Biomaterials 2017; 153:27-48. [PMID: 29096399 DOI: 10.1016/j.biomaterials.2017.10.026] [Citation(s) in RCA: 238] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 10/12/2017] [Accepted: 10/15/2017] [Indexed: 02/06/2023]
Abstract
Thermoresponsive surfaces, prepared by grafting of poly(N-isopropylacrylamide) (PIPAAm) or its copolymers, have been investigated for biomedical applications. Thermoresponsive cell culture dishes that show controlled cell adhesion and detachment following external temperature changes, represent a promising application of thermoresponsive surfaces. These dishes can be used to fabricate cell sheets, which are currently used as effective therapies for patients. Thermoresponsive microcarriers for large-scale cell cultivation have also been developed by taking advantage of the thermally modulated cell adhesion and detachment properties of thermoresponsive surfaces. Furthermore, thermoresponsive bioseparation systems using thermoresponsive surfaces for separating and purifying pharmaceutical proteins and therapeutic cells have been developed, with the separation systems able to maintain their activity and biological potency throughout the procedure. These applications of thermoresponsive surfaces have been improved with progress in preparation techniques of thermoresponsive surfaces, such as polymerization methods, and surface modification techniques. In the present review, the various types of PIPAAm-based thermoresponsive surfaces are summarized by describing their preparation methods, properties, and successful biomedical applications.
Collapse
Affiliation(s)
- Kenichi Nagase
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo 105-8512, Japan; Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, TWIns, 8-1 Kawadacho, Shinjuku, Tokyo 162-8666, Japan.
| | - Masayuki Yamato
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, TWIns, 8-1 Kawadacho, Shinjuku, Tokyo 162-8666, Japan
| | - Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30 Shibakoen, Minato, Tokyo 105-8512, Japan
| | - Teruo Okano
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, TWIns, 8-1 Kawadacho, Shinjuku, Tokyo 162-8666, Japan; Cell Sheet Tissue Engineering Center (CSTEC) and Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah, 30 South 2000 East, Salt Lake City, Utah 84112, USA.
| |
Collapse
|
17
|
Sepehrifar R, Boysen RI, Danylec B, Yang Y, Saito K, Hearn MT. Design, synthesis and application of a new class of stimuli-responsive separation materials. Anal Chim Acta 2017; 963:153-163. [DOI: 10.1016/j.aca.2017.01.061] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2016] [Revised: 01/25/2017] [Accepted: 01/29/2017] [Indexed: 11/29/2022]
|
18
|
Wang HS, Song M, Hang TJ. Functional Interfaces Constructed by Controlled/Living Radical Polymerization for Analytical Chemistry. ACS APPLIED MATERIALS & INTERFACES 2016; 8:2881-2898. [PMID: 26785308 DOI: 10.1021/acsami.5b10465] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The high-value applications of functional polymers in analytical science generally require well-defined interfaces, including precisely synthesized molecular architectures and compositions. Controlled/living radical polymerization (CRP) has been developed as a versatile and powerful tool for the preparation of polymers with narrow molecular weight distributions and predetermined molecular weights. Among the CRP system, atom transfer radical polymerization (ATRP) and reversible addition-fragmentation chain transfer (RAFT) are well-used to develop new materials for analytical science, such as surface-modified core-shell particles, monoliths, MIP micro- or nanospheres, fluorescent nanoparticles, and multifunctional materials. In this review, we summarize the emerging functional interfaces constructed by RAFT and ATRP for applications in analytical science. Various polymers with precisely controlled architectures including homopolymers, block copolymers, molecular imprinted copolymers, and grafted copolymers were synthesized by CRP methods for molecular separation, retention, or sensing. We expect that the CRP methods will become the most popular technique for preparing functional polymers that can be broadly applied in analytical chemistry.
Collapse
Affiliation(s)
- Huai-Song Wang
- Department of Pharmaceutical Analysis, China Pharmaceutical University , Nanjing, 210009, China
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education , Nanjing 210009, China
| | - Min Song
- Department of Pharmaceutical Analysis, China Pharmaceutical University , Nanjing, 210009, China
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education , Nanjing 210009, China
| | - Tai-Jun Hang
- Department of Pharmaceutical Analysis, China Pharmaceutical University , Nanjing, 210009, China
- Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University), Ministry of Education , Nanjing 210009, China
| |
Collapse
|
19
|
Nagase K, Okano T. Thermoresponsive-polymer-based materials for temperature-modulated bioanalysis and bioseparations. J Mater Chem B 2016; 4:6381-6397. [DOI: 10.1039/c6tb01003b] [Citation(s) in RCA: 83] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
In this review, bioseparations using thermoresponsive polymers are summarized. Thermoresponsive chromatography for separating bioactive compounds and proteins, and cell separations using thermoresponsive polymers and their properties are reviewed.
Collapse
Affiliation(s)
- Kenichi Nagase
- Institute of Advanced Biomedical Engineering and Science
- Tokyo Women's Medical University
- TWIns
- Tokyo 162-8666
- Japan
| | - Teruo Okano
- Institute of Advanced Biomedical Engineering and Science
- Tokyo Women's Medical University
- TWIns
- Tokyo 162-8666
- Japan
| |
Collapse
|
20
|
Liang Y, Liu Z, Dai R, Meng W, Deng Y. Influence of Graft Density of Poly (N-Isopropylacrylamide)-Grafted Silica on Separation Performance. Chromatographia 2015. [DOI: 10.1007/s10337-015-2966-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
21
|
Application of polymeric macroporous supports for temperature-responsive chromatography of pharmaceuticals. J Chromatogr A 2015; 1407:90-9. [DOI: 10.1016/j.chroma.2015.06.028] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Revised: 06/01/2015] [Accepted: 06/10/2015] [Indexed: 01/29/2023]
|
22
|
Lorenzo RA, Carro AM, Concheiro A, Alvarez-Lorenzo C. Stimuli-responsive materials in analytical separation. Anal Bioanal Chem 2015; 407:4927-48. [DOI: 10.1007/s00216-015-8679-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 03/30/2015] [Accepted: 04/07/2015] [Indexed: 02/07/2023]
|
23
|
Ayano E, Kanazawa H. Temperature-responsive smart packing materials utilizing multi-functional polymers. ANAL SCI 2014; 30:167-73. [PMID: 24420259 DOI: 10.2116/analsci.30.167] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Polymers that respond to small changes in environmental stimuli with large, sometimes discontinuous changes in their physical state or properties, are often called "smart" polymers. Poly(N-isopropylacrylamide), PNIPAAm, is one of the most representative smart polymer that exhibits a thermally reversible soluble-insoluble change in the vicinity of its lower critical solution temperature (LCST) at 32°C in aqueous solution. Temperature-responsive chromatography for the separation of biomolecules utilizing the poly(N-isopropylacrylamide) (PNIPAAm)-modified stationary phase is performed with an aqueous mobile phase without using an organic solvent. The surface properties and function of the stationary phase are controlled by external temperature changes without changing the mobile-phase composition. The separation of the biomolecules, such as nucleotides, was achieved by a dual temperature- and pH-responsive chromatography system. The electrostatic and hydrophobic interactions could be modulated simultaneously with the temperature in an aqueous mobile phase. Additionally, we also prepared functional copolymers composed of N-isopropylacrylamide (NIPAAm) and amino acid derivative or naphthyl alanine derivative, which have temperature-responsiveness and molecular recognition. These separation systems would have potential applications in the separation of biomolecules.
Collapse
Affiliation(s)
- Eri Ayano
- Faculty of Pharmacy, Keio University
| | | |
Collapse
|
24
|
Liu Z, Su R, Liang X, Liang Y, Deng Y, Li Y, Dai R. A thermally switchable chromatographic material for selective capture and rapid release of proteins and nucleotides. RSC Adv 2014. [DOI: 10.1039/c3ra41454j] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
25
|
Islam MR, Gao Y, Li X, Serpe MJ. Responsive polymers for biosensing and protein delivery. J Mater Chem B 2014; 2:2444-2451. [DOI: 10.1039/c3tb21657h] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Responsive polymers have found their way into numerous sensing and drug delivery platforms; some examples of biosensing and protein delivery are highlighted here.
Collapse
Affiliation(s)
- Molla R. Islam
- Department of Chemistry
- University of Alberta
- Edmonton, Canada
| | - Yongfeng Gao
- Department of Chemistry
- University of Alberta
- Edmonton, Canada
| | - Xue Li
- Department of Chemistry
- University of Alberta
- Edmonton, Canada
| | | |
Collapse
|
26
|
Ali F, Kim YS, Lee JW, Cheong WJ. Catalyst assisted synthesis of initiator attached silica monolith particles via isocyanate-hydroxyl reaction for production of polystyrene bound chromatographic stationary phase of excellent separation efficiency. J Chromatogr A 2014; 1324:115-20. [DOI: 10.1016/j.chroma.2013.11.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2013] [Revised: 11/08/2013] [Accepted: 11/09/2013] [Indexed: 10/26/2022]
|
27
|
Preparation of monodispersed macroporous core–shell molecularly imprinted particles and their application in the determination of 2,4-dichlorophenoxyacetic acid. J Chromatogr A 2014; 1323:11-7. [DOI: 10.1016/j.chroma.2013.11.002] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2013] [Revised: 10/31/2013] [Accepted: 11/01/2013] [Indexed: 01/07/2023]
|
28
|
Uemukai T, Torisaki M, Hamanaka T, Ishifune M. Stereoselective partitioning of organic substrates by thermoresponsive polymers in aqueous phases. J Appl Polym Sci 2013. [DOI: 10.1002/app.39603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Toru Uemukai
- Department of Applied Chemistry, Graduate School of Science and Engineering; Kinki University; Osaka; 577-8502; Japan
| | - Masashi Torisaki
- Department of Applied Chemistry, Graduate School of Science and Engineering; Kinki University; Osaka; 577-8502; Japan
| | - Takahiro Hamanaka
- Department of Applied Chemistry, Graduate School of Science and Engineering; Kinki University; Osaka; 577-8502; Japan
| | - Manabu Ishifune
- Department of Applied Chemistry, Graduate School of Science and Engineering; Kinki University; Osaka; 577-8502; Japan
| |
Collapse
|
29
|
Ali F, Cheong WJ, ALOthman ZA, ALMajid AM. Polystyrene bound stationary phase of excellent separation efficiency based on partially sub-2μm silica monolith particles. J Chromatogr A 2013; 1303:9-17. [DOI: 10.1016/j.chroma.2013.06.016] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2012] [Revised: 06/11/2013] [Accepted: 06/11/2013] [Indexed: 11/28/2022]
|
30
|
Responsive polymers for analytical applications: A review. Anal Chim Acta 2013; 789:17-32. [DOI: 10.1016/j.aca.2013.05.009] [Citation(s) in RCA: 71] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2013] [Revised: 05/01/2013] [Accepted: 05/04/2013] [Indexed: 11/24/2022]
|
31
|
Nagase K, Kobayashi J, Kikuchi A, Akiyama Y, Kanazawa H, Okano T. Thermally modulated cationic copolymer brush on monolithic silica rods for high-speed separation of acidic biomolecules. ACS APPLIED MATERIALS & INTERFACES 2013; 5:1442-1452. [PMID: 23394252 DOI: 10.1021/am302889j] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Poly(N-isopropylacrylamide (IPAAm)-co-2-(dimethylamino)ethylmethacrylate(DMAEMA)-co-tert-butylacrylamide (tBAAm)), a thermoresponsive-cationic-copolymer, brush-grafted monolithic-silica column was prepared through surface-initiated atom transfer radical polymerization (ATRP) for effective thermoresponsive anion-exchange chromatography matrices. ATRP-initiator was grafted on monolithic silica-rod surfaces by flowing a toluene solution containing ATRP initiator into monolithic silica-rod columns. IPAAm, DMAEMA, and tBAAm monomers and CuCl/CuCl₂/Me₆TREN, an ATRP catalytic system, were dissolved in 2-propanol, and the reaction solution was pumped into the preprepared initiator modified columns at 25 °C for 16 h. The constructed copolymer-brush structure on monolithic silica-rod surface was confirmed by X-ray photoelectron spectroscopy (XPS), elemental analysis, scanning electron microscopy (SEM) observation, and gel permeation chromatography (GPC) measurement of grafted copolymer. The prepared monolithic silica-rod columns were also characterized by chromatographic analysis. The cationic copolymer brush modified monolithic silica-rod columns were able to separate adenosine nucleotides with a shorter analysis time (4 min) than thermoresponsive copolymer brush-modified silica-bead-packed columns, because of the reduced diffusion path length of monolithic supporting materials. These results indicated that thermoresponsive cationic copolymer brush grafted monolithic silica-rod column prepared by ATRP was a promising tool for analyzing acidic-bioactive compounds with a remarkably short analysis time.
Collapse
Affiliation(s)
- Kenichi Nagase
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, TWIns, 8-1 Kawadacho, Shinjuku, Tokyo 162-8666, Japan
| | | | | | | | | | | |
Collapse
|
32
|
Idota N, Kikuchi A, Kobayashi J, Sakai K, Okano T. Modulation of graft architectures for enhancing hydrophobic interaction of biomolecules with thermoresponsive polymer-grafted surfaces. Colloids Surf B Biointerfaces 2012; 99:95-101. [DOI: 10.1016/j.colsurfb.2011.10.033] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2011] [Revised: 10/16/2011] [Accepted: 10/18/2011] [Indexed: 10/15/2022]
|
33
|
Mallik AK, Qiu H, Takafuji M, Ihara H. Selectivity enhancement for the separation of tocopherols and steroids by integration of highly ordered weak interaction sites along the polymer main chain. Anal Bioanal Chem 2012; 404:229-38. [DOI: 10.1007/s00216-012-6098-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2011] [Revised: 03/19/2012] [Accepted: 05/02/2012] [Indexed: 10/28/2022]
|
34
|
Nagase K, Kobayashi J, Kikuchi A, Akiyama Y, Kanazawa H, Okano T. High stability of thermoresponsive polymer-brush-grafted silica beads as chromatography matrices. ACS APPLIED MATERIALS & INTERFACES 2012; 4:1998-2008. [PMID: 22452297 DOI: 10.1021/am201832b] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Thermo-responsive chromatography matrices with three types of graft architecture were prepared, and their separation performance and stability for continuous use were investigated. Poly(N-isopropylacrylamide)(PIPAAm) hydrogel-modified silica beads were prepared by a radical polymerization through modified 4,4'-azobis(4-cyanovaleric acid) and N,N'-methylenebisacrylamide. Dense PIPAAm brush-grafted silica beads and dense poly(N-tert-Butylacrylamide (tBAAm)-b-IPAAm) brush-grafted silica beads were prepared through a surface-initiated atom transfer radical polymerization (ATRP) using CuCl/CuCl(2)/ Tris(2-(N,N-dimethylamino)ethyl)amine (Me(6)TREN) as an ATRP catalytic system and 2-propanol as a reaction solvent. Dense PIPAAm brush-grafted silica beads exhibited the highest separation performance because of their strong hydrophobic interaction between the densely grafted well-defined PIPAAm brush on silica-bead surfaces and analytes. Using an alkaline mobile phase, dense themoresponsive polymer brushes, especially having a hydrophobic basal layer, exhibited a high stability for continuous use, because polymer brush on the silica bead surfaces prevented the access of water to silica surface, leading to the hydrolysis of silica and cleavage of grafted polymers. Thus, the precisely modulating graft configuration of thermoresponsive polymers provided chromatography matrices with a high separation efficiency and stability for continuous use, resulting in elongating the longevity of chromatographic column.
Collapse
Affiliation(s)
- Kenichi Nagase
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, TWIns, Shinjuku, Tokyo, Japan
| | | | | | | | | | | |
Collapse
|
35
|
Coad BR, Lu Y, Meagher L. A substrate-independent method for surface grafting polymer layers by atom transfer radical polymerization: reduction of protein adsorption. Acta Biomater 2012; 8:608-18. [PMID: 22023749 DOI: 10.1016/j.actbio.2011.10.006] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2011] [Revised: 08/31/2011] [Accepted: 10/05/2011] [Indexed: 11/25/2022]
Abstract
A general method for producing low-fouling biomaterials on any surface by surface-initiated grafting of polymer brushes is presented. Our procedure uses radiofrequency glow discharge thin film deposition followed by macro-initiator coupling and then surface-initiated atom transfer radical polymerization (SI-ATRP) to prepare neutral polymer brushes on planar substrates. Coatings were produced on substrates with variable interfacial composition and mechanical properties such as hard inorganic/metal substrates (silicon and gold) or flexible (perfluorinated poly(ethylene-co-propylene) film) and rigid (microtitre plates) polymeric materials. First, surfaces were functionalized via deposition of an allylamine plasma polymer thin film followed by covalent coupling of a macro-initiator composed partly of ATRP initiator groups. Successful grafting of a hydrophilic polymer layer was achieved by SI-ATRP of N,N'-dimethylacrylamide in aqueous media at room temperature. We exemplified how this method could be used to create surface coatings with significantly reduced protein adsorption on different material substrates. Protein binding experiments using labelled human serum albumin on grafted materials resulted in quantitative evidence for low-fouling compared to control surfaces.
Collapse
|
36
|
Wang H, Dong X, Yang M. Development of separation materials using controlled/living radical polymerization. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2011.07.012] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
37
|
Nagase K, Kimura A, Shimizu T, Matsuura K, Yamato M, Takeda N, Okano T. Dynamically cell separating thermo-functional biointerfaces with densely packed polymer brushes. ACTA ACUST UNITED AC 2012. [DOI: 10.1039/c2jm31797d] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
38
|
Nagase K, Mizutani Akimoto A, Kobayashi J, Kikuchi A, Akiyama Y, Kanazawa H, Okano T. Effect of reaction solvent on the preparation of thermo-responsive stationary phase through a surface initiated atom transfer radical polymerization. J Chromatogr A 2011; 1218:8617-28. [DOI: 10.1016/j.chroma.2011.09.082] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Revised: 09/27/2011] [Accepted: 09/30/2011] [Indexed: 10/16/2022]
|
39
|
Dai X, He Y, Wei Y, Gong B. Preparation of hydrophilic polymer-grafted polystyrene beads for hydrophilic interaction chromatography via surface-initiated atom transfer radical polymerization. J Sep Sci 2011; 34:3115-22. [PMID: 21972137 DOI: 10.1002/jssc.201100443] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Revised: 08/10/2011] [Accepted: 08/11/2011] [Indexed: 11/08/2022]
Abstract
A one-step procedure based on surface-initiated atom transfer radical polymerization (SI-ATRP) to hydrophilize monodisperse poly(chloromethylstyrene-co-divinylbenzene) beads has been presented in this work, using 2-hydroxyl-3-[4-(hydroxymethyl)-1H-1,2,3-triazol-1-yl]propyl 2-methylacrylate (HTMA) as a monomer. The chain length of the grafted poly(HTMA) was controlled via varying the ratio of HTMA to initiator on the surface of the beads. When using the grafted beads as a stationary phase in hydrophilic interaction chromatography (HILIC), good resolution for nucleobases/nucleosides was obtained with acetonitrile aqueous solution as an eluent; while for phenolic acids and glycosides, they could be eluted and separated in the presence of TFA. The retention time of the solutes increased with the amount of the grafted HTMA. The retention mechanisms of solutes were investigated by the effects of mobile phase composition and buffer pH on the retention of solutes. The results illustrated that the retention behaviors of the tested solutes were dominated by hydrogen bonding interaction and electrostatic interaction. From the chemical structure of the ligands, the modified beads could not only be used as a stationary phase in HILIC, but also act as a useful building block to develop new stationary phases for other chromatographic modes such as affinity media.
Collapse
Affiliation(s)
- Xiaojun Dai
- Key Laboratory of Synthetic and Natural Function Molecule Chemistry of Ministry of Education, College of Chemistry and Material Science, Northwest University, Xi'an, PR China
| | | | | | | |
Collapse
|
40
|
Nagase K, Kobayashi J, Kikuchi A, Akiyama Y, Kanazawa H, Okano T. Thermoresponsive polymer brush on monolithic-silica-rod for the high-speed separation of bioactive compounds. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:10830-10839. [PMID: 21740046 DOI: 10.1021/la201360p] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Poly(N-isopropylacrylamide), one of the most utilized thermoresponsive polymers, brush-grafted monolithic-silica columns were prepared through surface-initiated atom transfer radical polymerization (ATRP) for effective thermoresponsive-chromatography matrices. ATRP initiator was grafted on monolithic silica-rod surfaces by flowing a toluene solution containing ATRP initiator into monolithic silica-rod columns. N-Isopropylacrylamide (IPAAm) monomer and CuCl/CuCl(2)/Me(6)TREN, an ATRP catalytic system, were dissolved in 2-propanol, and the reaction solution was pumped into the preprepared initiator-modified columns at 25 °C for 16 h. The constructed PIPAAm-brush structure on the monolithic silica-rod surface was confirmed by XPS, elemental analysis, SEM observation, and GPC measurement of grafted PIPAAm. The prepared monolithic silica-rod columns were also characterized by chromatographic analysis. PIPAAm-brush-modified monolithic silica-rod columns were able to separate hydrophobic steroids with a short analysis time (10 min), compared to PIPAAm-brush-modified silica-beads-packed columns, because of the horizontally limited diffusion path length of monolithic supporting materials. Additionally, diluted PIPAAm-brush monolithic silica-rod column gave a further shorting analysis time (5 min). These results indicated (1) surface-initiated ATRP constructed PIPAAm-brush structures on monolithic silica-rod surfaces and (2) PIPAAm-brush grafted monolithic silica-rod column prepared by ATRP was a promising tool for analyzing hydrophobic-bioactive compounds with a short analysis time.
Collapse
Affiliation(s)
- Kenichi Nagase
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, TWIns, 8-1 Kawadacho, Shinjuku, Tokyo 162-8666, Japan
| | | | | | | | | | | |
Collapse
|
41
|
Investigation of temperature-responsivity and aqueous chromatographic characteristics of a thermo-responsive monolithic column. Talanta 2011; 85:1193-8. [DOI: 10.1016/j.talanta.2011.05.034] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2011] [Revised: 05/11/2011] [Accepted: 05/19/2011] [Indexed: 11/19/2022]
|
42
|
Shen Y, Qi L, Wei X, Zhang R, Mao L. Preparation of well-defined environmentally responsive polymer brushes on monolithic surface by two-step atom transfer radical polymerization method for HPLC. POLYMER 2011. [DOI: 10.1016/j.polymer.2011.06.041] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
43
|
Kanazawa H, Okano T. Temperature-responsive chromatography for the separation of biomolecules. J Chromatogr A 2011; 1218:8738-47. [PMID: 21570080 DOI: 10.1016/j.chroma.2011.04.015] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2011] [Revised: 04/04/2011] [Accepted: 04/06/2011] [Indexed: 12/14/2022]
Abstract
Temperature-responsive chromatography for the separation of biomolecules utilizing poly(N-isopropylacrylamide) (PNIPAAm) and its copolymer-modified stationary phase is performed with an aqueous mobile phase without using organic solvent. The surface properties and function of the stationary phase are controlled by external temperature changes without changing the mobile-phase composition. This analytical system is based on nonspecific adsorption by the reversible transition of a hydrophilic-hydrophobic PNIPAAm-grafted surface. The driving force for retention is hydrophobic interaction between the solute molecules and the hydrophobized polymer chains on the stationary phase surface. The separation of the biomolecules, such as nucleotides and proteins was achieved by a dual temperature- and pH-responsive chromatography system. The electrostatic and hydrophobic interactions could be modulated simultaneously with the temperature in an aqueous mobile phase, thus the separation system would have potential applications in the separation of biomolecules. Additionally, chromatographic matrices prepared by a surface-initiated atom transfer radical polymerization (ATRP) exhibit a strong interaction with analytes, because the polymerization procedure forms a densely packed polymer, called a polymer brush, on the surfaces. The copolymer brush grafted surfaces prepared by ATRP was an effective tool for separating basic biomolecules by modulating the electrostatic and hydrophobic interactions. Applications of thermally responsive columns for the separations of biomolecules are reviewed here.
Collapse
Affiliation(s)
- Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30, Shibakoen, Tokyo 105-8512, Japan
| | | |
Collapse
|
44
|
Liu YY, Chen H, Ishizu K. Facile surface immobilization of ATRP initiators on colloidal polymers for grafting brushes and application to colloidal crystals. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2011; 27:1168-1174. [PMID: 21214212 DOI: 10.1021/la103560j] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Bromo-initiators for atom transfer radical polymerization (ATRP) were successfully immobilized on the surfaces of cross-linked poly(methyl methacrylate) (PMMA) spheres by soap-free emulsion polymerization using CBr(4) as the chain transfer agent. Subsequent surface-initiated ATRP (SI-ATRP) afforded a layer of PMMA brushes covalently attached to the sphere surfaces. Colloidal crystal films of these monodisperse spheres were then studied to identify the relationship between variation in particle diameter and the optical properties. The particle diameters were controlled by varying the feed monomer proportions in soap-free emulsion polymerization and the thickness of the grafted brush layer. It was found that the particle diameter could successfully be controlled to obtain crystal films that produce a variety of brilliant colors in the visible region. The results of this study can provide useful information for facile preparation of surface-immobilized ATRP initiators on colloidal polymers and can be employed for grafting polymer brushes.
Collapse
Affiliation(s)
- Yi-Yu Liu
- Department of Chemical and Materials Engineering, National Central University, 300 Jhongda Road, Jhongli 32001, Taiwan
| | | | | |
Collapse
|
45
|
Golden AL, Battrell CF, Pennell S, Hoffman AS, Lai JJ, Stayton PS. Simple fluidic system for purifying and concentrating diagnostic biomarkers using stimuli-responsive antibody conjugates and membranes. Bioconjug Chem 2011; 21:1820-6. [PMID: 20845976 DOI: 10.1021/bc100169y] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We report a simple fluidic system that can purify and concentrate diagnostic biomarkers through the capture and triggered release of stimuli-responsive polymer-antibody conjugates at porous membranes that are grafted with the same stimuli-responsive polymer. This technique is applied here to the capture and detection of a model streptavidin antigen and subsequently to clinical ranges of the malaria antigen Plasmodium falciparum histidine-rich protein 2 (PfHRP2) from spiked human plasma. The carboxyl end-groups of semi-telechelic poly(N-isopropylacrylamide) (pNIPAAm) synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization were modified with tetrafluorophenol to yield amine-reactive ester groups for conjugation to amine groups of anti-streptavidin and anti-PfHRP2 antibodies. Stimuli-responsive membranes were constructed from 1.2 μm pore-size, hydroxylated, nylon-6,6 filters (Loprodyne, from Pall Corporation). The surface hydroxyl groups on the filters were conjugated to a 2-ethylsulfanylthiocarbonylsulfanyl-2-methyl propionic acid (EMP) RAFT chain transfer agent, and the surface-grafted pNIPAAm was obtained by subsequent polymerization. The number average molecular weight (Mn) and polydispersity indices (PDI) of the surface grafts were characterized, and membranes with either 4100 and 8400 dalton pNIPAAm grafts showed greater than 80% anti-streptavidin capture efficiency. The 8400 dalton-graft membrane showed the highest release efficiency, and it was demonstrated that at 0.2 nM starting concentration the streptavidin could be concentrated approximately 40-fold by releasing into a small 50 μL volume. This concentrator system was applied to the capture and concentration of the PfHRP2 antigen, and results showed that the PfHRP2 antigen could be processed and detected at clinically relevant concentrations of this malaria biomarker.
Collapse
Affiliation(s)
- Allison L Golden
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
| | | | | | | | | | | |
Collapse
|
46
|
Preparation and characterization of temperature-responsive poly(N-isopropylacrylamide-co-N,N′-methylenebisacrylamide) monolith for HPLC. J Chromatogr A 2011; 1218:286-92. [DOI: 10.1016/j.chroma.2010.11.037] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2010] [Revised: 11/18/2010] [Accepted: 11/18/2010] [Indexed: 11/23/2022]
|
47
|
Lee SM, Zaidi SA, Cheong WJ. A New Stationary Phase Prepared from Ground Silica Monolith Particles by Reversible Addition-Fragmentation Chain Transfer Polymerization. B KOREAN CHEM SOC 2010. [DOI: 10.5012/bkcs.2010.31.10.2943] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
48
|
Zhang Z, Feng X, Xu F, Liu X, Liu BF. “Click” chemistry-based surface modification of poly(dimethylsiloxane) for protein separation in a microfluidic chip. Electrophoresis 2010; 31:3129-36. [DOI: 10.1002/elps.201000208] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
49
|
Hattori Y, Nagase K, Kobayashi J, Kikuchi A, Akiyama Y, Kanazawa H, Okano T. Hydration of poly(N-isopropylacrylamide) brushes on micro-silica beads measured by a fluorescent probe. Chem Phys Lett 2010. [DOI: 10.1016/j.cplett.2010.03.082] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
50
|
Nagase K, Kumazaki M, Kanazawa H, Kobayashi J, Kikuchi A, Akiyama Y, Annaka M, Okano T. Thermoresponsive polymer brush surfaces with hydrophobic groups for all-aqueous chromatography. ACS APPLIED MATERIALS & INTERFACES 2010; 2:1247-1253. [PMID: 20380388 DOI: 10.1021/am100122h] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
For developing thermoresponsive chromatographic matrices with a strong hydrophobicity, poly(N-isopropylacrylamide-co-n-butyl methacrylate) (poly(IPAAm-co-BMA)) brush grafted silica beads were prepared through a surface-initiated atom transfer radical polymerization (ATRP) with a CuCl/CuCl(2)/Me(6)TREN catalytic system in 2-propanol at 25 degrees C for 16 h. The prepared beads were characterized by chromatographic analysis. Chromatograms of the benzoic-acid family and phenol as model analytes were obtained with high-resolution peaks because of their strong hydrophobic interactions to the densely grafted hydrophobized copolymers on the beads. Retention times of the analytes increased with the increase in BMA composition ratio. Dehydration of grafted copolymer with large BMA composition was performed at low temperature. These results indicated that the copolymer-brush-grafted surface prepared by ATRP was an effective tool for separating hydrophilic analytes at low temperature through modulating the strong hydrophobic interaction.
Collapse
Affiliation(s)
- Kenichi Nagase
- Institute of Advanced Biomedical Engineering and Science, Tokyo Women's Medical University, Tokyo 162-8666, Japan
| | | | | | | | | | | | | | | |
Collapse
|