1
|
Karas D, Bužga M, Stejskal D, Kocna P, Holéczy P, Novotná A, Švagera Z. Breath Tests Used in the Context of Bariatric Surgery. Diagnostics (Basel) 2022; 12:diagnostics12123170. [PMID: 36553178 PMCID: PMC9777764 DOI: 10.3390/diagnostics12123170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 12/01/2022] [Accepted: 12/11/2022] [Indexed: 12/23/2022] Open
Abstract
This review article focuses on the use of breath tests in the field of bariatrics and obesitology. The first part of the review is an introduction to breath test problematics with a focus on their use in bariatrics. The second part provides a brief history of breath testing. Part three describes how breath tests are used for monitoring certain processes in various organs and various substances in exhaled air and how the results are analyzed and evaluated. The last part covers studies that described the use of breath tests for monitoring patients that underwent bariatric treatments. Although the number of relevant studies is small, this review could promote the future use of breath testing in the context of bariatric treatments.
Collapse
Affiliation(s)
- Daniel Karas
- Institute of Laboratory Medicine, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
| | - Marek Bužga
- Department of Human Movement Studies, Faculty of Education, University of Ostrava, Fráni Šrámka 3, 709 00 Ostrava, Czech Republic
- Department of Physiology and Pathophysiology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
- Institute of Laboratory Medicine, University Hospital Ostrava, 17. Listopadu 1790/5, 708 52 Ostrava, Czech Republic
- Correspondence:
| | - David Stejskal
- Institute of Laboratory Medicine, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
- Institute of Laboratory Medicine, University Hospital Ostrava, 17. Listopadu 1790/5, 708 52 Ostrava, Czech Republic
| | - Petr Kocna
- Institute of Medical Biochemistry and Laboratory Diagnostics, 1st Faculty of Medicine, Charles University in Prague, Kateřinská 1660/32, 121 08 Prague, Czech Republic
| | - Pavol Holéczy
- Department of Surgery, Vítkovice Hospital, Zalužanského 1192/15, 703 00 Ostrava, Czech Republic
- Department of Surgical Disciplines, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
| | - Adéla Novotná
- Department of Epidemiology and Public Health, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
| | - Zdeněk Švagera
- Institute of Laboratory Medicine, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
- Institute of Laboratory Medicine, University Hospital Ostrava, 17. Listopadu 1790/5, 708 52 Ostrava, Czech Republic
| |
Collapse
|
2
|
Dalby FR, Fuchs A, Feilberg A. Methanogenic pathways and δ 13 C values from swine manure with a cavity ring-down spectrometer: Ammonia cross-interference and carbon isotope labeling. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8628. [PMID: 31658498 DOI: 10.1002/rcm.8628] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 10/05/2019] [Accepted: 10/05/2019] [Indexed: 06/10/2023]
Affiliation(s)
- Frederik R Dalby
- Department of Engineering, Air Quality Engineering, Aarhus University, Finlandsgade 10, 8200, Aarhus N, Denmark
| | - Andrea Fuchs
- Department of Engineering, Air Quality Engineering, Aarhus University, Finlandsgade 10, 8200, Aarhus N, Denmark
| | - Anders Feilberg
- Department of Engineering, Air Quality Engineering, Aarhus University, Finlandsgade 10, 8200, Aarhus N, Denmark
| |
Collapse
|
3
|
Best LMJ, Takwoingi Y, Siddique S, Selladurai A, Gandhi A, Low B, Yaghoobi M, Gurusamy KS. Non-invasive diagnostic tests for Helicobacter pylori infection. Cochrane Database Syst Rev 2018; 3:CD012080. [PMID: 29543326 PMCID: PMC6513531 DOI: 10.1002/14651858.cd012080.pub2] [Citation(s) in RCA: 74] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
BACKGROUND Helicobacter pylori (H pylori) infection has been implicated in a number of malignancies and non-malignant conditions including peptic ulcers, non-ulcer dyspepsia, recurrent peptic ulcer bleeding, unexplained iron deficiency anaemia, idiopathic thrombocytopaenia purpura, and colorectal adenomas. The confirmatory diagnosis of H pylori is by endoscopic biopsy, followed by histopathological examination using haemotoxylin and eosin (H & E) stain or special stains such as Giemsa stain and Warthin-Starry stain. Special stains are more accurate than H & E stain. There is significant uncertainty about the diagnostic accuracy of non-invasive tests for diagnosis of H pylori. OBJECTIVES To compare the diagnostic accuracy of urea breath test, serology, and stool antigen test, used alone or in combination, for diagnosis of H pylori infection in symptomatic and asymptomatic people, so that eradication therapy for H pylori can be started. SEARCH METHODS We searched MEDLINE, Embase, the Science Citation Index and the National Institute for Health Research Health Technology Assessment Database on 4 March 2016. We screened references in the included studies to identify additional studies. We also conducted citation searches of relevant studies, most recently on 4 December 2016. We did not restrict studies by language or publication status, or whether data were collected prospectively or retrospectively. SELECTION CRITERIA We included diagnostic accuracy studies that evaluated at least one of the index tests (urea breath test using isotopes such as 13C or 14C, serology and stool antigen test) against the reference standard (histopathological examination using H & E stain, special stains or immunohistochemical stain) in people suspected of having H pylori infection. DATA COLLECTION AND ANALYSIS Two review authors independently screened the references to identify relevant studies and independently extracted data. We assessed the methodological quality of studies using the QUADAS-2 tool. We performed meta-analysis by using the hierarchical summary receiver operating characteristic (HSROC) model to estimate and compare SROC curves. Where appropriate, we used bivariate or univariate logistic regression models to estimate summary sensitivities and specificities. MAIN RESULTS We included 101 studies involving 11,003 participants, of which 5839 participants (53.1%) had H pylori infection. The prevalence of H pylori infection in the studies ranged from 15.2% to 94.7%, with a median prevalence of 53.7% (interquartile range 42.0% to 66.5%). Most of the studies (57%) included participants with dyspepsia and 53 studies excluded participants who recently had proton pump inhibitors or antibiotics.There was at least an unclear risk of bias or unclear applicability concern for each study.Of the 101 studies, 15 compared the accuracy of two index tests and two studies compared the accuracy of three index tests. Thirty-four studies (4242 participants) evaluated serology; 29 studies (2988 participants) evaluated stool antigen test; 34 studies (3139 participants) evaluated urea breath test-13C; 21 studies (1810 participants) evaluated urea breath test-14C; and two studies (127 participants) evaluated urea breath test but did not report the isotope used. The thresholds used to define test positivity and the staining techniques used for histopathological examination (reference standard) varied between studies. Due to sparse data for each threshold reported, it was not possible to identify the best threshold for each test.Using data from 99 studies in an indirect test comparison, there was statistical evidence of a difference in diagnostic accuracy between urea breath test-13C, urea breath test-14C, serology and stool antigen test (P = 0.024). The diagnostic odds ratios for urea breath test-13C, urea breath test-14C, serology, and stool antigen test were 153 (95% confidence interval (CI) 73.7 to 316), 105 (95% CI 74.0 to 150), 47.4 (95% CI 25.5 to 88.1) and 45.1 (95% CI 24.2 to 84.1). The sensitivity (95% CI) estimated at a fixed specificity of 0.90 (median from studies across the four tests), was 0.94 (95% CI 0.89 to 0.97) for urea breath test-13C, 0.92 (95% CI 0.89 to 0.94) for urea breath test-14C, 0.84 (95% CI 0.74 to 0.91) for serology, and 0.83 (95% CI 0.73 to 0.90) for stool antigen test. This implies that on average, given a specificity of 0.90 and prevalence of 53.7% (median specificity and prevalence in the studies), out of 1000 people tested for H pylori infection, there will be 46 false positives (people without H pylori infection who will be diagnosed as having H pylori infection). In this hypothetical cohort, urea breath test-13C, urea breath test-14C, serology, and stool antigen test will give 30 (95% CI 15 to 58), 42 (95% CI 30 to 58), 86 (95% CI 50 to 140), and 89 (95% CI 52 to 146) false negatives respectively (people with H pylori infection for whom the diagnosis of H pylori will be missed).Direct comparisons were based on few head-to-head studies. The ratios of diagnostic odds ratios (DORs) were 0.68 (95% CI 0.12 to 3.70; P = 0.56) for urea breath test-13C versus serology (seven studies), and 0.88 (95% CI 0.14 to 5.56; P = 0.84) for urea breath test-13C versus stool antigen test (seven studies). The 95% CIs of these estimates overlap with those of the ratios of DORs from the indirect comparison. Data were limited or unavailable for meta-analysis of other direct comparisons. AUTHORS' CONCLUSIONS In people without a history of gastrectomy and those who have not recently had antibiotics or proton ,pump inhibitors, urea breath tests had high diagnostic accuracy while serology and stool antigen tests were less accurate for diagnosis of Helicobacter pylori infection.This is based on an indirect test comparison (with potential for bias due to confounding), as evidence from direct comparisons was limited or unavailable. The thresholds used for these tests were highly variable and we were unable to identify specific thresholds that might be useful in clinical practice.We need further comparative studies of high methodological quality to obtain more reliable evidence of relative accuracy between the tests. Such studies should be conducted prospectively in a representative spectrum of participants and clearly reported to ensure low risk of bias. Most importantly, studies should prespecify and clearly report thresholds used, and should avoid inappropriate exclusions.
Collapse
Affiliation(s)
- Lawrence MJ Best
- Royal Free Campus, UCL Medical SchoolDepartment of SurgeryRowland Hill StreetLondonUKNW32PF
| | - Yemisi Takwoingi
- University of BirminghamInstitute of Applied Health ResearchEdgbastonBirminghamUKB15 2TT
| | | | | | | | | | - Mohammad Yaghoobi
- McMaster University and McMaster University Health Sciences CentreDivision of Gastroenterology1200 Main Street WestHamiltonONCanada
| | | | | |
Collapse
|
4
|
Paul D, Meijer HAJ. Intracavity OptoGalvanic Spectroscopy not suitable for ambient level radiocarbon detection. Anal Chem 2015; 87:9025-32. [PMID: 26252648 DOI: 10.1021/acs.analchem.5b02226] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
IntraCavity OptoGalvanic Spectroscopy as a radiocarbon detection technique was first reported by the Murnick group at Rutgers University, Newark, NJ, in 2008. This technique for radiocarbon detection was presented with tremendous potentials for applications in various fields of research. Significantly cheaper, this technique was portrayed as a possible complementary technique to the more expensive and complex accelerator mass spectrometry. Several groups around the world started developing this technique for various radiocarbon related applications. The IntraCavity OptoGalvanic Spectroscopy setup at the University of Groningen was constructed in 2012 in close collaboration with the Murnick group for exploring possible applications in the fields of radiocarbon dating and atmospheric monitoring. In this paper we describe a systematic evaluation of the IntraCavity OptoGalvanic Spectroscopy setup at Groningen for radiocarbon detection. Since the IntraCavity OptoGalvanic Spectroscopy setup was strictly planned for dating and atmospheric monitoring purposes, all the initial experiments were performed with CO2 samples containing contemporary levels and highly depleted levels of radiocarbon. Because of recurring failures in differentiating the two CO2 samples, with the radiocarbon concentration 3 orders of magnitude apart, CO2 samples containing elevated levels of radiocarbon were prepared in-house and experimented with. All results obtained thus far at Groningen are in sharp contrast to the results published by the Murnick group and rather support the results put forward by the Salehpour group at Uppsala University. From our extensive test work, we must conclude that the method is unsuited for ambient level radiocarbon measurements, and even highly enriched CO2 samples yield insignificant signal.
Collapse
Affiliation(s)
- Dipayan Paul
- Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ESRIG), University of Groningen , Nijenborgh 4, 9747 AG, Groningen, The Netherlands
| | - Harro A J Meijer
- Centre for Isotope Research (CIO), Energy and Sustainability Research Institute Groningen (ESRIG), University of Groningen , Nijenborgh 4, 9747 AG, Groningen, The Netherlands
| |
Collapse
|
5
|
Broide E, Shirin H. Evaluation of Exalenz Bioscience's BreathID for Helicobacter pylori detection. Expert Rev Mol Diagn 2015; 15:299-312. [PMID: 25634297 DOI: 10.1586/14737159.2015.982537] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Carbon-labeled urea breath tests, which have high sensitivity and specificity, are the preferred method used in epidemiological studies, screening dyspeptic patients and assessing eradication or recurrence of Helicobacter pylori infection. The principle of the (13)C-urea breath test relies upon the ability of the H. pylori urease to hydrolyze the orally administered (13)C-urea. The BreathID (Exalenz Bioscience Inc., Union, NJ, USA) provides a competitive solution for breath testing, including unique features such as automatic continuous breath collection and analysis. This is an unattended convenient test, with no human error as the correct part of the breath is collected and patients' assistance is not required. The test results are available in real time at the point of care and enable shortened breath testing procedures. Additionally, several studies showing expanded utility of the BreathID in pediatrics, after therapy and during proton pump inhibitors intake, further support the safety and performance of the BreathID in the diagnosis of H. pylori.
Collapse
Affiliation(s)
- Efrat Broide
- The Kamila Gonczarowski, Institute of Gastroenterology, Assaf Harofeh Medical Center, Zerifin, 70300 Israel
| | | |
Collapse
|
6
|
Murnick DE, Dogru O, Ilkmen E. Intracavity optogalvanic spectroscopy. An analytical technique for 14C analysis with subattomole sensitivity. Anal Chem 2008; 80:4820-4. [PMID: 18533685 PMCID: PMC2770733 DOI: 10.1021/ac800751y] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We show a new ultrasensitive laser-based analytical technique, intracavity optogalvanic spectroscopy, allowing extremely high sensitivity for detection of (14)C-labeled carbon dioxide. Capable of replacing large accelerator mass spectrometers, the technique quantifies attomoles of (14)C in submicrogram samples. Based on the specificity of narrow laser resonances coupled with the sensitivity provided by standing waves in an optical cavity and detection via impedance variations, limits of detection near 10(-15) (14)C/(12)C ratios are obtained. Using a 15-W (14)CO2 laser, a linear calibration with samples from 10(-15) to >1.5 x 10(-12) in (14)C/(12)C ratios, as determined by accelerator mass spectrometry, is demonstrated. Possible applications include microdosing studies in drug development, individualized subtherapeutic tests of drug metabolism, carbon dating and real time monitoring of atmospheric radiocarbon. The method can also be applied to detection of other trace entities.
Collapse
Affiliation(s)
- Daniel E Murnick
- Department of Physics, Rutgers University, Newark, New Jersey 07102, USA.
| | | | | |
Collapse
|
7
|
Abstract
AIM: To validate an optimized 13C-urea breath test (13C-UBT) protocol for the diagnosis of H pylori infection that is cost-efficient and maintains excellent diagnostic accuracy.
METHODS: 70 healthy volunteers were tested with two simplified 13C-UBT protocols, with test meal (Protocol 2) and without test meal (Protocol 1). Breath samples were collected at 10, 20 and 30 min after ingestion of 50 mg 13C-urea dissolved in 10 mL of water, taken as a single swallow, followed by 200 mL of water (pH 6.0) and a circular motion around the waistline to homogenize the urea solution. Performance of both protocols was analyzed at various cut-off values. Results were validated against the European protocol.
RESULTS: According to the reference protocol, 65.7% individuals were positive for H pylori infection and 34.3% were negative. There were no significant differences in the ability of both protocols to correctly identify positive and negative H pylori individuals. However, only Protocol 1 with no test meal achieved accuracy, sensitivity, specificity, positive and negative predictive values of 100%. The highest values achieved by Protocol 2 were 98.57%, 97.83%, 100%, 100% and 100%, respectively.
CONCLUSION: A 10 min, 50 mg 13C-UBT with no test meal using a cut-off value of 2-2.5 is a highly accurate test for the diagnosis of H pylori infection at a reduced cost.
Collapse
|
8
|
Mégraud F, Lehours P. Helicobacter pylori detection and antimicrobial susceptibility testing. Clin Microbiol Rev 2007; 20:280-322. [PMID: 17428887 PMCID: PMC1865594 DOI: 10.1128/cmr.00033-06] [Citation(s) in RCA: 463] [Impact Index Per Article: 27.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The discovery of Helicobacter pylori in 1982 was the starting point of a revolution concerning the concepts and management of gastroduodenal diseases. It is now well accepted that the most common stomach disease, peptic ulcer disease, is an infectious disease, and all consensus conferences agree that the causative agent, H. pylori, must be treated with antibiotics. Furthermore, the concept emerged that this bacterium could be the trigger of various malignant diseases of the stomach, and it is now a model for chronic bacterial infections causing cancer. Most of the many different techniques involved in diagnosis of H. pylori infection are performed in clinical microbiology laboratories. The aim of this article is to review the current status of these methods and their application, highlighting the important progress which has been made in the past decade. Both invasive and noninvasive techniques will be reviewed.
Collapse
Affiliation(s)
- Francis Mégraud
- INSERM U853, and Université Victor Segalen Bordeaux 2, and Laboratoire de Bactériologie, Hôpital Pellegrin, Place Amélie Raba-Léon, 33076 Bordeaux cedex, France.
| | | |
Collapse
|
9
|
Murnick DE, Okil JO. Use of the optogalvanic effect (OGE) for isotope ratio spectrometry of 13CO2 and 14CO2. ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES 2005; 41:363-71. [PMID: 16543191 DOI: 10.1080/10256010500384440] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The use of isotopic carbon dioxide lasers for determination of carbon (and oxygen) isotope ratios was first demonstrated in 1994. Since then a commercial device called LARA, has been manufactured and used for Helicobacter pylori breath tests using (13)C-labelled urea. The major advantages of the optogalvanic effect compared with other infrared absorption isotope ratio measurement techniques are its lack of optical background and its high sensitivity resulting from a signal gain proportional to laser power. Continuous normalisation using two cells, a standard and sample, lead to high accuracy as well as precision. Recent advances in continuous flow measurement of (13)C/(12)C ratios of CO(2) in air and extensions of the technique to (14)C, which can be analysed as a stable isotope, are described.
Collapse
Affiliation(s)
- Daniel E Murnick
- Department of Physics, Rutgers University, Newark, NJ, 07102, USA
| | | |
Collapse
|
10
|
Gisbert JP, Pajares JM. Review article: 13C-urea breath test in the diagnosis of Helicobacter pylori infection -- a critical review. Aliment Pharmacol Ther 2004; 20:1001-17. [PMID: 15569102 DOI: 10.1111/j.1365-2036.2004.02203.x] [Citation(s) in RCA: 242] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The urea breath test is a non-invasive, simple and safe test which provides excellent accuracy both for the initial diagnosis of Helicobacter pylori infection and for the confirmation of its eradication after treatment. Some studies have found no differences between urea breath test performed under non-fasting conditions. The simplicity, good tolerance and economy of the citric acid test meal probably make its systematic use advisable. The urea breath test protocol may be performed with relatively low doses (<100 mg) of urea: 75 mg or even 50 mg seem to be sufficient. With the most widely used protocol (with citric acid and 75 mg of urea), excellent accuracy is obtained when breath samples are collected as early as 10-15 min after urea ingestion. A unique and generally proposed cut-off level is not possible because it has to be adapted to different factors, such as the test meal, the dose and type of urea, or the pre-/post-treatment setting. Fortunately, because positive and negative urea breath test results tend to cluster outside of the range between 2 and 5 per thousand, a change in cut-off value within this range would be expected to have little effect on clinical accuracy of the test.
Collapse
Affiliation(s)
- J P Gisbert
- Department of Gastroenterology, University Hospital of La Princesa, Madrid, Spain.
| | | |
Collapse
|
11
|
Wyse CA, Preston T, Yam PS, Sutton DGM, Christley RM, Hotchkiss JW, Mills CA, Glidle A, Cumming DRS, Cooper JM, Love S. Current and future uses of breath analysis as a diagnostic tool. Vet Rec 2004; 154:353-60. [PMID: 15074325 DOI: 10.1136/vr.154.12.353] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The analysis of exhaled breath is a potentially useful method for application in veterinary diagnostics. Breath samples can be easily collected from animals by means of a face mask or collection chamber with minimal disturbance to the animal. After the administration of a 13C-labelled compound the recovery of 13C in breath can be used to investigate gastrointestinal and digestive functions. Exhaled hydrogen can be used to assess orocaecal transit time and malabsorption, and exhaled nitric oxide, carbon monoxide and pentane can be used to assess oxidative stress and inflammation. The analysis of compounds dissolved in the aqueous phase of breath (the exhaled breath condensate) can be used to assess airway inflammation. This review summarises the current status of breath analysis in veterinary medicine, and analyses its potential for assessing animal health and disease.
Collapse
Affiliation(s)
- C A Wyse
- Institute of Comparative Medicine, University of Glasgow Veterinary School, Bearsden, Glasgow G61 1QH
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Horner G, Lau S, Kantor Z, Lohmannsroben HG. Isotope selective analysis of CO2with tunable diode laser (TDL) spectroscopy in the NIR. Analyst 2004; 129:772-8. [PMID: 15284924 DOI: 10.1039/b404552c] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The performance of a home-built tunable diode laser (TDL) spectrometer, aimed at multi-line detection of carbon dioxide, has been evaluated and optimized. In the regime of the (30(0)1)(III) <-- (000) band of (12)CO(2) around 1.6 microm, the dominating isotope species (12)CO(2), (13)CO(2), and (12)C(18)O(16)O were detected simultaneously without interference by water vapor. Detection limits in the range of few ppmv were obtained for each species utilizing wavelength modulation (WM) spectroscopy with balanced detection in a long-path absorption cell set-up. High sensitivity in conjunction with high precision -- typically +/-1 (per thousand) and +/-6 (per thousand) for 3% and 0.7% of CO(2), respectively -- renders this experimental approach a promising analytical concept for isotope-ratio determination of carbon dioxide in soil and breath gas. For a moderate (12)CO(2) line, the pressure dependence of the line profile was characterized in detail, to account for pressure effects on sensitive measurements.
Collapse
Affiliation(s)
- Gerald Horner
- Institute of Chemistry, Physical Chemistry, Potsdam University, Karl-Liebknecht Str. 24-25, D-14476 Potsdam-Golm, Germany
| | | | | | | |
Collapse
|
13
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:446-457. [PMID: 11333450 DOI: 10.1002/jms.91] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|